Premier External TD. Installation Manual INS352-3

Similar documents
Installation Manual Premier Elite IXP-W

Installation Manual. Premier IXP-W INS538

Installation Manual Premier Elite Orbit QD/DT INS483-2

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. External Sounder & Strobe Unit

Installation Manual. Odyssey X Series INS627-2

Guidance on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS) Regulations 2012

KM300 Carbon Monoxide Detection System Installation Manual

EVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR. instruction manual. evolution EVC-P Conventional Photoelectric Smoke Detector

TruVision IR Turret Camera TVT-2202/TVT-4202 Installation Guide

DUAL ZONE OUTDOOR PIR MS-12TE & MS-12FE

Commercial Series TriTech Motion Detector. Reference Guide

IR Speed Dome. Quick Guide UD.6L0201B1357A01

Installation Manual Premier LCD/LCDL INS180-4

HX-40/40AM/ 40DAM. High Mount Outdoor Detector

FEC403EN Installation Manual

Portable Gas Detector RP110. User Guide. Explosive gas detection SEMICONDUCTOR sensor technology Intrinsically safe. Conformity EMC EN50270.

D-TECT Dual Tech. GJD360 Triple Technology External Detector

Commercial Series TriTech+ Motion Detector with Anti-mask

1X-F Series Installation Manual

Installation Manual. Wiegand Interface Unit Four-State (WIU-4) North America T F Asia T F

Record of Amendments. Version Date Amendment Section/page affected

Mobrey MCU900 Series 4 20 ma + HART Compatible Controller

INSTRUCTIONS. OJ-DV-Relay-Module. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS. Optional module for OJ-DV motor controller

PQS performance specification

Fortimo LED Line Gen2 Module

D-Tect 2 GJD300 Quad PIR Movement Detector

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

Operating Instructions

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

HX-80NRAM. High Mount Outdoor Detector

Active Infrared Multi Beam Sensors

Dual-Network LCD Keyboard Intelligent Alarm

Polycarbonate External Sounder & Strobe Unit

Fortimo LED Line High Flux Module

Active Infrared Multi Beam Sensors. R Series

Use & Care Manual Contemporary Electric Fires

PQS performance specification

DS-K2600 Series. Access Controller. Quick Start Guide UD01216B-A

This symbol indicates prohibition. The specific prohibited action is provided in and/or around the figure.

Iron Man Plus Workstation Monitor, Installation, Operation and Maintenance USER GUIDE TB Features and Components. Description.

VS-AXESS-4DLX Installation Manual

KFP-CF Series Operation Manual

RoHS CERTIFICATE OF COMPLIANCE FOR INTELLITOUCH SUPER FLAT PROFILE SCREENS

USE & CARE MANUAL WALL HANGING FIRE. CO9126 V2_110512

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

Features. Figure 1. Recommended Application

Temporary wireless battery operated fire system from Channel Safety Systems

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

RADIATION FROST DETECTOR

KI-398-B-RGL LOUDSPEAKER INSTRUCTION MANUAL

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

TX7110. Intelligent Heat Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

ATS1235 Advanced Wireless DGP on 868 MHz AM Installation Sheet

VX-402, VX-402REC CONTENTS FEATURES

Owner & Operator s Manual. Table of Contents

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev CA June 2016

PROCESSING UNIT II V Hz V Hz. Table of Contents

Passive Infrared Motion Detector 5420/90P. Installation Instructions

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

LC-151 Dual-Tech Motion Sensor (Single PIR & Microwave) with adjustable Pet Immunity INSTALLATION INSTRUCTIONS & USER MANUAL P/N: ver.

DI601AM Outdoor PIR/AM Detector Installation Sheet

HULME MARTIN HEAT SEALERS

IFS Fiber Module Installation & Operation Instructions

Description. Optex Incorporated

CE GUIDELINE IEC. CENELEC (Comité Européen de Normalisation Electrotechnique European Electrotechnical Standardisation Comitee)

GP2Y1010AU0F. Compact Optical Dust Sensor. Description. Compliance. Applications. Features GP2Y1010AU0F. 1. Compliant with RoHS directive (2002/95/EC)

AZSG10000/AZSG10005/AZSG10010 ABUS Wired Outdoor Siren

Installation and Operation Manual

AX-100TFR/AX-200 TFR INTRODUCTION 1-1 BEFORE YOUR OPERATION BATTERY OPERATED PHOTOELECTRIC DETECTOR. Warning FEATURES. Caution. Warning.

General Routing Interface

ELECTRO-FENCE TM. Fence Protection System. Installation Manual. EF_Install_V2

(EN) RevC AS610-AS630 Outdoor Siren Installation Sheet.pdf. Remark: Rev. Date: Modif. no.

MICROtrac MICROPROCESSOR BASED WATER TREATMENT CONTROLLER. Installation and Operation Manual REV. L

SIGA-CC1 Single Input Signal Module Installation Sheet

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

Long-Range Barrier Sensors

Movement Detector GJD 300

TruVision Bullet IR Camera Pocket Guide

design line performance line Guardall DesignLine & PerformanceLine detector series 2015 Peace of mind

ZP2 Series Operation Manual

LUX Hardwired - Installation Notes

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector

ELECTRIC WALL HANGING FIREPLACE SUITE FUI0005_V2_ USE & CARE MANUAL

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature

English. Italiano. Português. Françias. Español

TruVision Bullet IR Camera Pocket Guide

This is a preview - click here to buy the full publication. IEC Quality Assessment System for Electronic Components (IECQ System)

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

Input module, input/output module

Smart BUS (S-BUS) Home Automation System Simplified Specification

Conventional Fire Alarm System 2014 V1.2

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

Use & Care Manual Inset Electric Fires

Installation instructions

1. CONTENTS OF PACK 2. TECHNICAL SPECIFICATIONS ... User Manual v1.1. Compatible with: ESIM264 v and up. ESIM364 all versions

D-TECT 3 IP. GJD260 IP Motion Detector

Installation Guide for models:

INSTRUCTION MANUAL. This product is only suitable for well insulated spaces or occasional use.

Original operating instructions Safety switch with guard locking AC901S AC902S

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

Transcription:

Premier External TD Installation Manual INS352-3

1. Accessing the Unit 1 2 Remove the top cap and loosen screw (screw retained in wall plate). Push up head unit and remove. 3 Use a flat head screwdriver to lever out both sides of the terminal cover as shown. 1 INS352-3

2. Choosing a Location Mounting height 1.0-1.4m (nominal 1.2m), measured to middle of unit. Mount perpendicular to ground. Parallel 1.0-1.4m Try to avoid direct sunlight. Avoid pointing at swaying bushes/trees and swaying clothes on a clothes line. Try to install the detector so its detection area is terminated by building/fences etc. This will reduce the effect of range variation caused by environmental changes. In the detection area try to avoid reflective surfaces such as standing water, swimming pools or polished floors as this can cause the detectors range or coverage to vary as reflected signals may be seen. INS352-3 2

3. Mounting the Unit Front View WALL MOUNTING For wall mounting, the cable should be brought through the wall into the cable entry hole. Cable Entry REAR TAMPER To enable the rear tamper, the breakaway keyhole section must be securely fixed to the mounting surface. Cable Entry Cable Channels Rear View SURFACE WIRING For surface wiring, use the appropriate knockout in the top or bottom of the unit. If wiring from the top, use the knockouts in the top cap and run the cable down the cable channels and into the unit as shown. Knockout in Top Cap Cable Entry Conduit Entry 3 INS352-3

Pole Mount Bracket Mounting POLE MOUNTING Using the pole mount kit (available separately) the unit can be mounted on poles with an outside diameter of 20-57mm. Assemble the kit around the pole as shown and tighten the 4 bolts. Hook the detector wall plate onto the kit and secure the remaining 2 bolts through the lower mounting holes. 1 ø 20-44mm 2 x4 x1 ø 45-57mm x4 3 x3 5 4 INS352-3 4

4. Wiring the Unit TERMINAL BLOCK 12V & 0V: 9-16 VDC. ALARM: NO/NC (selectable) relay output. 18 Ω, 50VDC, 10A Max. TAMPER: RLED: AUX: NC Relay output. 18 Ω, 50VDC, 10A Max. 0V: LED off. 12V or No Connection: LED on. NC relay input. NC = Normally Closed, NO = Normally Open JP1: Pulse Count 2 3 4 0.3-3./s JP2: Sensitivity HIGH MEDIUM LOW JP3: Alarm NC: alarm relay normally closed. NO: alarm relay normally open. 5 INS352-3

JP4: LED JP5: MODE Day/Night Mode Detector is always operating. Night Mode Detector only operates at night. JP6 & JP7: END OF LINE JUMPERS JP7 Selects the End-of-Line resistance. Equivalent to wiring a resistor of the selected value as shown. ALARM - JP7 JP6 Selects the resistance across the alarm relay. Equivalent to wiring a resistor of the selected value as shown. TAMPER - JP6 JP8 & JP9: see Auxiliary section (page 9) INS352-3 6

5. Range Adjustment - PIR Bottom of head unit To adjust the range of the detector, rotate the circular section shown until the desired range is shown in the window. Note: Range can vary due to environmental conditions. To reduce the risk of false alarms always select the lowest range possible for the installation. Specified ranges are valid for nominal 1.2m mounting height. Selected Range Side View Position - 12m Coverage 1.2m 2m 4m 6m 8m 1 12m Position - 8m Coverage 1.2m 2m 4m 6m 8m 1 12m Position - 5m Coverage 1.2m 2m 4m 6m 8m 1 12m Position - 2m Coverage 1.2m 2m 4m 6m 8m 1 12m 7 INS352-3

6. Coverage Area Bottom of head unit Bottom of head unit Top View Top View 12m 1 8m 6m 4m 2m 2m 4m 6m 8m 1 12m 12m 1 8m 6m 4m 2m 2m 4m 6m 8m 1 12m 2m 4m 6m 8m 1 12m 2m 4m 6m 8m 1 12m Active detection coverage Active detection coverage 45 90 45 90 90 Walk-testing With the range, sensitivity, coverage and pulse count set as desired, enable the LEDs and walk-through the area of protection. Confirm the LEDs light and alarm relay activates. INS352-3 8

7. Auxiliary Input With the Auxiliary input enabled (JP8), a second detector with a normally closed relay output can be connected to the Premier External detector to give directional detection. The order of activation required to give an alarm signal is set by the direction jumper (JP9). When this is set to 1st the auxiliary detector must be activated first followed by the Premier External detector within 1 minute to give a valid alarm signal. With the jumper set to 2nd, the Premier External detector must be activated followed by the auxiliary detector within 1 minute. If directional detection is not required, disable the auxiliary input using JP8. JP8 ON OFF AUX Premier External PIR JP9 ALARM 1st NO ALARM NO ALARM 2nd JP9 AUX Premier External PIR 2nd ALARM 1st NO ALARM NO ALARM Regulatory Information Supplier: Texecom Ltd, St. Crispin Way, Haslingden, Lancashire, BB4 4PW, UK. Weee Directive: 2002/96/EC (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info. RoHs Directive: 2002/95/EC RoHS Compliant. Hereby, Texecom declares that this device does not contain lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls (PBB) or polybrominated depheny ethers (PBDE) in more than the percentage specified by EU directive 2002/95/EC, except exemptions stated in EU directive 2002/95/EC annex. CE Directive: 2004/108/EC (CE directive): Hereby, Texecom declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 2004/108/EC. Maintenance: Test yearly by the installer Warranty: 2 year replacement warranty Security grade: EN Grade 2 Environmental class: Class III Standards: EN50131-1 Disclaimer: The Premier External TD is not a complete alarm system, but only its part. Therefore Texecom does not accept any responsibility or liability for any damage that is claimed to be a result of an incorrect functioning of the Premier External TD detector. Texecom reserves the right to change the specification without a prior notice. Certificate Number: FM 35285 MADE IN ENGLAND The Premier External detector is protected by UK & International Designs. Premier is a Trademark of Texecom Ltd. 9 INS352-3

8. Specifications Mounting Height: Supply Voltage: Current Drain (typical): Detection Method: Range: Alarm Output: Tamper Detection: Tamper Output: LED Indication: Environmental Protection: Waterproof Coating: EMC: 1.0-1.4m, 1.2m nominal 9-16 VDC 28mA Dual, non-overlapping, digital PIR 12m max. Adjustable to 8m, 5m and 2m NC/NO selectable relay. Rated 50VDC, 10A, 18Ω Wall and case. Sealed non-mechanical switch. NC relay. Rated 50VDC, 10A, 18Ω Red alarm indication IP65 Conformal EN 50130-4: 1996, A1 1998, A2 2002. EN 55022: Class B 9. Physical Specifications 89mm 86.5mm -35 C (-31 F) to +60 C (+140 F) 25m -35 C (-31 F) to +55 C (+131 F) 550g (20oz) approx. INS352-3 10

Texecom Limited, Bradwood Court, St. Crispin Way, Haslingden, Lancashire BB4 4PW, England. Technical Support: UK Customers Tel: 08456 300 600 (Calls charged at 3.36 pence per minute from a BT landline. Calls from other networks may vary.) International Customers Tel: +44 1278 686197 Email: techsupport@texe.com www.texe.com Texecom Limited 2011. INS352-3 C20111219