Low Profile Unit Cooler. ECM Motors. All-Temp²B. Small to Medium Walk - Ins. Coolers & Freezer Applications. Now available with optional

Similar documents
LOW PROFILE UNIT COOLER

LOW PROFILE UNIT COOLER

Super-Flo Low Profile Unit Cooler

Center Mount Unit Coolers

Low Velocity Center Mount Unit Cooler. Technical Guide. Models LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost.

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax

SPECIFICATIONS FOR WALK-IN COOLERS & FREEZERS

Reach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

Low Flow Unit Coolers

High Profile Evaporator

MS Series UNIT COOLERS. Technical Bulletin: MSUC_005_ Products that provide lasting solutions.

Lo-Aire Unit Coolers. Technical Guide. bn-lftb May Models LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost.

LOW PROFILE UNIT COOLER. Technical Guide. Models RLC Air Defrost ELC/EFC Electric Defrost GLC Hot Gas Defrost. CH-LOPTB May,

Low Profile Unit Coolers

KTL Two-Way Low Profile Evaporators

Low Profile Unit Coolers

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_001_ Products that provide lasting solutions.

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_005_ Products that provide lasting solutions.

Page ` RLP R1. Supersedes all earlier versions LIST PRICES April, 2018

KR Series COMPACT UNIT COOLERS. Technical Bulletin: KRUC_005_ Products that provide lasting solutions.

LH and GH/GL Series UNIT COOLERS. Technical Bulletin. Products that provide lasting solutions.

Page ` RLP A. Supersedes all earlier versions LIST PRICES Prices effective 7/2/18

SM/SV Series PRODUCT COOLERS. Technical Bulletin. Products that provide lasting solutions.

Reach-In Unit Coolers. Technical Guide. Models TA TL C VA BBM BBL KMK RAMK BTO U. LK-RITB June

Installation, Operation, and Maintenance Information

RLP Page. Prices effective January 1, Supersedes all earlier versions LIST PRICES

Reach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5

KTL Two-Way Low Profile Unit Coolers

BTL Two-Way Low Profile Evaporators

Specifications and Performance S2H

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Digi-Motor. ECM for Commercial Refrigeration. Toll Free (800) Fax (631)

Slim Contour Unit Cooler

PACKAGE AIR CONDITIONER

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

MACH N-407 Heat Pump Air-Cooled Chiller

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_002_ Products that provide lasting solutions.

PRODUCT. TWB Two-Way Air Defrost Unit Coolers PRODUCT DATA & INSTALLATION. High Temperature (35 o F / 1.7 o C or Higher) Applications

Commercial High-Efficiency Condensing Units

Description. Construction

TLV Low Velocity Evaporators

CONDENSING UNITS-AIR SUBMITTED BY : Poppy Hudson PROJECT : Brooks Landing REV DATE : 07 Dec 2017 ORDER # : A00

CENTRAL SPLIT UNIT UNIC

LUH HORIZONTAL FAN-FORCED UNIT HEATER

AIR COOLED PACKAGED CHILLER

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Glass Door Merchandiser. Model RM-49

Levitor II. AIR-COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS (Available for Fluid Cooler Applications)

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

KUH. Horizontal Unit Heater. Applications. Description

T P A 120 S 4 S N 1 Y

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

10-Bilt. Walk-In Coolers & Freezers With Matching Refrigeration Systems FEATURES OPTIONS

SECTION FAN COIL UNITS

roof finish is 26 gauge acrylic coated stucco galvanized steel.080 textured aluminum interior floor finish, where required

Product Data. Features/Benefits. 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes. 2to4NominalTons

Packaged refrigeration system Technical Guide

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Product Chillers A P P L I C AT I O N S

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

TABLE OF CONTENTS. FCV Nomenclature 3. FCV Features & Construction 4. FCV Engineering Specifications 5. FCV Fan/Coil Data 6

Air-Cooled Condensers

SECTION WATER-SOURCE UNITARY HEAT PUMPS

CR1 Series Triton Corrosion Resistant Washdown Heaters

& MAINTENANCE INSTRUCTIONS INSTALLATION, OPERATION INDUSTRIAL COOLERS & FREEZERS WALK-IN COOLERS SERIES: EK, EM, EH, EI, EB, EF

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Wall mount refrigeration systems available. PRS-2 SERIES Packaged Refrigeration Systems & Walk-in Combinations

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

Glass Door Merchandiser. Model RM-45-SD

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Commercial High-Efficiency Condensing Units

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

EMI ENGINEERING SUBMITTAL

SeasonMaker ThinLine Fan-coil Units

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

Kramersaver Air Cooled Condensing Units

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR LOW PROFILE-UNIT COOLERS AND DUAL FLOW UNIT COOLER

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

Compak Unit Coolers. LCA - Air Defrost LCE - Electric Defrost LCH - Hot Gas Defrost. Bulletin LC-03A August 2004 (Replaces LC-03 3/03)

HEATING & COOLING SPLIT SYSTEM HEAT PUMP & AIR CONDITIONER 14 SEER INTERTHERM SERIES

2 shp 13 lc 1 36 t - 1 a

Air-Cooled Condensers

C13-Series Engineering Guide

TECHNICAL GUIDE VARIABLE SPEED AIR HANDLERS DESCRIPTION FEATURES Rev. A (0105)

KR Electrical Defrost Unit Coolers (PN E108318_E)

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

KCC Centrifugal Fan Air Cooled Condensers

BN-HGDTB June Replaces BN-HGDTB, March Mohave. Technical Guide

3000 Series Fan Forced Ceiling Heater Series Commercial Fan Forced Ceiling Heater

Glass Door Merchandiser

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR INDUSTRIAL COOLERS

VERTICAL FAN COIL UNITS

Transcription:

Now available with optional ECM Motors High Efficiency / High Reliability Low rofile Unit Cooler ublication No. 100.14 January, 2008 MEA Air Defrost - 3,900 to 39,000 BTUH Electric Defrost - 3,600 to 28,000 BTUH Hot Gas Defrost - 3,600 to 28,000 BTUH Small to Medium Walk - ns Coolers & reezer Applications Visit us on the Web: www.russellcoil.com 221 S. Berry St.,.O. Box 1030, Brea, CA 92822-1030 Tel: (714) 529-1935 ax: (714) 529-7203

eatures The All-Temp²B is the original low profile unit cooler that has established an industry standard as being the all purpose design for walk-in coolers, freezers and other applications. They feature an air draw-through design offering air, electric and hot gas defrost models. Sizes There are 35 sizes available with 3,700 to 39,000 BTUH at a 10 TD ranging from 740 to 4,980 cfm. One through six fan models are available. Housing Rust-free, heavy gauge, textured Aluminum casing is light weight yet durable. Each fan section is baffled to prevent short cycling of the air. The unit is designed to mount flush to the ceiling and meets all NS requirements. Slotted hangers are provided for easy installation. Drain fittings are installed in the horizontal position to gain more usable headroom in low ceiling applications. The end panels now are hinged to open up out for easy access to both the piping and electrical ends. Optional expansion valves can be conveniently installed inside the cabinet. Coil Seamless Copper tubes are staggered and mechanically expanded into corrugated Aluminum fins and heavy gauge tube sheets to achieve maximum heat transfer and strength. Die formed fin collars provide even fin spacing. in spacings available are 4, 6, and 8 fins per inch. Sweat connections are standard on all models and optional field installed flare connection kits are available at no extra charge. Electrical Available in 115V, 208/230V, and 460V (see pages 4 & 5). All components are factory wired to convenient screw-type terminal strips. A large compartment is supplied internal to the unit for all electrical components and is easily accessible by removing the end panel. All models are UL & cul listed. Electric Defrost Available on all models with the prefix HTE. Designed for use where electric heat is used to defrost. lacement of the heaters internal to the coil allows for an extremely rapid and efficient defrost. This arrangement enables the heat to be conducted through the fins from the center out for an even defrost pattern. All heaters are wired to a terminal strip to allow a quick field change-over from single phase to three phase, 230V to 460V and vice versa. A lower heater is installed close to the drain pan for fast, reliable drainage. A defrost termination thermostat (DT) terminates the defrost cycle when the temperature is satisfied. A heater safety thermostat is installed to prevent heaters from overheating above 75 in case of DT failure. All heaters are flexible and can be easily replaced within 12 inches of the end of the units. A fan delay thermostat is supplied to allow the warm coil to cool after a defrost cycle prior to the fans turning on. Complete electric defrost refrigeration systems are available. Motors Standard motors are 1/20 H, permanently lubricated, ball bearing, with thermal overload protection. Available in 115V, 208/230V and 460V, single phase. Optional high efficiency SC and ECM motors are available in 115V and 230V. ans Heavy duty 12 Aluminum fans are balanced to provide vibration-free operation. Our new low throw black plastic fan guards have an improved air pattern. The optional epoxy resin high throw fan guard moves air up to 50 feet. Air Defrost All models with the prefix HTA are designed for use in coolers of 35 and warmer. Complete air defrost systems for off-cycle or timed air defrost are available. High efficiency SC or ECM fan motors Coated Aluminum fins or Copper ins Baked white enamel housing Optional eatures 2 Epoxy resin high throw guards for up to 50 ft. Reheat kits (not UL listed) actory mounted expansion valves

HTG s optional ECM motors bring the benefits inherent to unit bearing motor design to the refrigeration Unit Cooler market. Large oil resevoir Totally enclosed construction Journal bearing machined into the cast iron endbell Spiral grooved shaft pump guarantees positive oil circulation Threaded shaft uses hubless fan blade. Energy Savings per Motor by Changing to More Efficient Unit Cooler Motors (baseded on Energy Cost of $0.10 per kwh) Motor Change S to SC 120 85 35 22 281 28 959 18 47 0.6 SC to EC 85 47 38 22 305 31 1041 20 51 2 S to EC 120 47 73 22 586 59 2000 38 97 1.3 Subtract 6% from total savings for medium temperature air defrost units that run 24 hours per day. S = 1/20 H Shaded pole motor (Standard motors) SC = 1/20 H SC motor (Optional motors available at additional cost) ECM = 50 Watt Electronically Commutated motor (Optional motors available at additional cost) 1 2 3 4 5 6 7 8 9 10 11 Yearly Savings per motor 3.88 7.76 11.64 15.52 19.39 23.27 27.15 31.03 34.91 38.79 42.67 $120 4.21 8.42 12.63 16.85 21.06 25.27 29.48 33.69 37.90 42.11 46.32 $100 Std Motor ower Watts/Mtr Change to Motor ower Watts/Mtr Reduced ower Watts/Mtr Run Time Hrs/ Day Motor Energy Savings kwh/yr Motor Energy Savings $/Yr Reduced Box Load MBTU/Yr Cond. Unit Energy Savings $/Yr Yearly ay Saving $ back in er Yrs MTR Dollars Saved $80 8.09 16.18 24.27 32.36 40.45 48.54 56.63 64.72 72.81 80.90 88.99 $60 SC to EC S to EC $40 $20 12 11 10 9 8 7 6 5 4 3 2 S to SC $0 1 2 3 4 5 6 7 8 9 10 11 12 Months of year Nomenclature HT A 1 8-41 B - A All-Temp²B Type of Defrost A = Air Defrost E = Electric Defrost Number of fans 3 Revision Code BTUH in hundreds ins per inch Voltage Code A = 115V B = 208/1/60 C = 230/1/60 D = 208-230/1/60 E = 208-230/3/60 = 460/1/60

Air Defrost / Specifications 8 6 4 BTUH Total an Motor AMS - 1 hase Model CM Number Capacity @ 25 S.T. Standard Motor Optional SC Motor Optional ECM Motor 10 TD 12 TD 115V 230V 460V 115V 230V 115V 230V HTA18-41B 4,100 4,900 800 2.0 1.0 0.5 1.0 0.5 0.9 0.45 HTA18-53B 5,300 6,400 770 2.0 1.0 0.5 1.0 0.5 0.9 0.45 HTA18-66B 6,600 7,900 740 2.0 1.0 0.5 1.0 0.5 0.9 0.45 HTA28-76B 7,600 9,100 1,460 4.0 2.0 1.0 2.0 1.0 1.8 0.90 HTA28-97B 9,700 11,600 1,420 4.0 2.0 1.0 2.0 1.0 1.8 0.90 HTA28-106B 10,600 12,700 1,540 4.0 2.0 1.0 2.0 1.0 1.8 0.90 HTA28-122B 12,200 14,600 1,380 4.0 2.0 1.0 2.0 1.0 1.8 0.90 HTA28-134B 13,400 16,100 1,480 4.0 2.0 1.0 2.0 1.0 1.8 0.90 HTA38-160B 16,000 19,200 2,310 6.0 3.0 1.5 3.0 1.5 2.7 1.35 HTA38-195B 19,500 23,400 2,220 6.0 3.0 1.5 3.0 1.5 2.7 1.35 HTA48-212B 21,200 25,400 3,080 8.0 4.0 2.0 4.0 2.0 3.6 1.80 HTA48-264B 26,400 31,700 2,960 8.0 4.0 2.0 4.0 2.0 3.6 1.80 HTA58-275B 27,500 33,000 3,850 10.0 5.0 2.5 5.0 2.5 4.5 2.25 HTA68-318B 31,800 38,200 4,620 12.0 6.0 3.0 6.0 3.0 5.4 2.70 HTA68-390B 39,000 46,800 4,440 12.0 6.0 3.0 6.0 3.0 5.4 2.70 HTA16-39B 3,900 4,700 830 2.0 1.0 0.5 1.0 0.5 0.9 0.45 HTA16-48B 4,800 5,800 800 2.0 1.0 0.5 1.0 0.5 0.9 0.45 HTA16-58B 5,800 7,000 780 2.0 1.0 0.5 1.0 0.5 0.9 0.45 HTA26-70B 7,000 8,400 1,540 4.0 2.0 1.0 2.0 1.0 1.8 0.90 HTA26-87B 8,700 10,400 1,500 4.0 2.0 1.0 2.0 1.0 1.8 0.90 HTA26-115B 11,500 13,800 1,560 4.0 2.0 1.0 2.0 1.0 1.8 0.90 HTA36-145B 14,500 17,400 2,400 6.0 3.0 1.5 3.0 1.5 2.7 1.35 HTA36-170B 17,000 20,400 2,340 6.0 3.0 1.5 3.0 1.5 2.7 1.35 HTA46-192B 19,200 23,000 3,200 8.0 4.0 2.0 4.0 2.0 3.6 1.80 HTA46-230B 23,000 27,600 3,120 8.0 4.0 2.0 4.0 2.0 3.6 1.80 HTA56-245B 24,500 29,400 4,000 10.0 5.0 2.5 5.0 2.5 4.5 2.25 HTA66-295B 29,500 35,400 4,800 12.0 6.0 3.0 6.0 3.0 5.4 2.70 HTA66-345B 34,500 41,400 4,680 12.0 6.0 3.0 6.0 3.0 5.4 2.70 HTA14-42B 4,200 5,000 830 2.0 1.0 0.5 1.0 0.5 0.9 0.45 HTA24-84B 8,400 10,100 1,660 4.0 2.0 1.0 2.0 1.0 1.8 0.90 HTA24-105B 10,500 12,600 1,620 4.0 2.0 1.0 2.0 1.0 1.8 0.90 HTA34-130B 13,000 15,600 2,490 6.0 3.0 1.5 3.0 1.5 2.7 1.35 HTA44-170B 17,000 20,400 3,320 8.0 4.0 2.0 4.0 2.0 3.6 1.80 HTA54-215B 21,500 25,800 4,150 10.0 5.0 2.5 5.0 2.5 4.5 2.25 HTA64-255B 25,500 30,600 4,980 12.0 6.0 3.0 6.0 3.0 5.4 2.70 (1) All fan motors are wired for single phase. Standard motors are shaded pole. High efficiency SC motors (ermanent Split Capacitor) and ECM (Electronically Commutated) motors are optional. Ordering nformation Required t is vital that the information listed below is given with each evaporator order. Orders without this information may be delayed. Evaporators with options such as solenoid and expansion valves will not be processed until all the required information is given. (1) Model Number (2) Type of Motor (3) Voltage, frequency and phase of motors and heaters (when applicable) (4) Refrigerant type (5) Evaporator temperature (6) Evaporator T.D. 4

Electric Defrost / Specifications 6 4 BTUH Capacity @ 10 T.D. Motor Amps¹ Heater Amps² Model CM Number Evaporator Temperature Standard SC ECM 208/230V 460V Watts -30-20 -10 +20 230V 460V 230V 230V 1 H 3 H 1 H HTE16-36B 3,400 3,600 3,700 3,900 830 1 0.5 0.5 0.45 4.4 2.6 2.2 1,000 HTE16-41B 3,900 4,100 4,300 4,800 800 1 0.5 0.5 0.45 4.4 2.6 2.2 1,000 HTE16-46B 4,400 4,600 4,800 5,800 780 1 0.5 0.5 0.45 4.4 2.6 2.2 1,000 HTE26-60B 5,700 6,000 6,200 7,000 1,540 2 1 1 0.90 7 6 3.5 1,600 HTE26-75B 7,100 7,500 7,800 8,700 1,500 2 1 1 0.90 7 6 3.5 1,600 HTE26-92B 8,700 9,200 9,600 11,500 1,560 2 1 1 0.90 8.7 7.5 4.4 2,000 HTE36-120B 11,400 12,000 12,500 14,500 2,400 3 1.5 1.5 1.35 13 11.3 6.4 3,000 HTE36-140B 13,300 14,000 14,600 17,000 2,340 3 1.5 1.5 1.35 13 11.3 6.4 3,000 HTE46-164B 15,000 16,400 17,100 19,200 3,200 4 2 2 1.80 17.4 15.1 8.7 4,000 HTE46-185B 17,600 18,500 19,200 23,000 3,120 4 2 2 1.80 17.4 15.1 8.7 4,000 HTE56-210B 20,000 21,000 21,800 24,500 4,000 5 2.5 2.5 2.25 18.8 10.9 5,000 HTE66-245B 23,300 24,500 25,500 29,500 4,800 6 3 3 2.70 22.6 13 6,000 HTE66-280B 26,600 28,000 29,100 34,500 4,680 6 3 3 2.70 22.6 13 6,000 HTE14-37B 3,500 3,700 3,800 4,200 830 1 0.5 0.5 0.45 4.4 2.6 2.2 1,000 HTE24-72B 6,800 7,200 7,500 8,400 1,660 2 1 1 0.90 8.7 7.5 4.4 2,000 HTE24-85B 8,100 8,500 8,800 10,500 1,620 2 1 1 0.90 8.7 7.5 4.4 2,000 HTE34-105B 10,000 10,500 10,900 13,000 2,490 3 1.5 1.5 1.35 13 11.3 6.4 3,000 HTE44-140B 13,300 14,000 14,600 17,000 3,320 4 2 2 1.80 17.4 15.1 8.7 4,000 HTE54-180B 17,100 18,000 18,700 21,500 4,150 5 2.5 2.5 2.25 18.8 10.9 5,000 HTE64-215B 20,400 21,500 22,400 25,500 4,980 6 3 3 2.70 22.6 13 6,000 (1) All fan motors are wired for single phase. Standard motors are shaded pole. High efficiency SC (ermanent Split Capacitor) & ECM (Electronically commutated) motors are optional. (2) or 208/230 volt models, heaters are wired as standard for single phase on 1 through 4 fan models. 5 and 6 fan models are wired 3 phase. 460 Volt models are only available in single phase and are compatible with all 3 phase systems. 5

hysical Data Models Refrigerant Connections TXV No. of Dimensions (nches) Ship TYE HTA HTE Wt. All Liquid HG Hangers Suction Suction (lbs.) HTA HTE A B C W 18-41B EXT 1/2 ODS 5/8 ODS 2 19 27½ 33 18-53B EXT 1/2 5/8 2 19 27½ 34 18-66B EXT 1/2 5/8 2 19 27½ 36 28-76B EXT 1/2 5/8 2 33 41½ 48 28-97B EXT 1/2 7/8 2 33 41½ 51 28-106B EXT 1/2 7/8 2 37 45½ 58 28-122B EXT 1/2 7/8 2 33 41½ 60 28-134B EXT 1/2 7/8 2 37 45½ 63 38-160B EXT 1/2 1-1/8 2 55 63½ 79 38-195B EXT 1/2 1-1/8 2 55 63½ 84 48-212B EXT 1/2 1-1/8 3 36½ 36½ 81½ 254 48-264B EXT 1/2 1-1/8 3 36½ 36½ 81½ 262 58-275B EXT 1/2 1-1/8 3 54½ 36½ 99½ 312 68-318B EXT 1/2 1-1/8 4 36½ 36 36½ 117½ 354 68-390B EXT 1/2 1-1/8 4 36½ 36 36½ 117½ 370 16-39B 16-36B EXT 1/2 ODS 5/8 ODS 5/8 ODS 5/8 ODS 2 19 27½ 41 16-48B 16-41B EXT 1/2 5/8 5/8 5/8 2 19 27½ 44 16-58B 16-46B EXT 1/2 5/8 5/8 5/8 2 19 27½ 47 26-70B 26-60B EXT 1/2 5/8 7/8 5/8 2 33 41½ 54 26-87B 26-75B EXT 1/2 7/8 7/8 5/8 2 33 41½ 55 26-115B 26-92B EXT 1/2 7/8 7/8 5/8 2 37 45½ 62 36-145B 36-120B EXT 1/2 7/8 7/8 5/8 2 55 63½ 78 36-170B 36-140B EXT 1/2 1-1/8 1-1/8 5/8 2 55 63½ 85 46-192B 46-164B EXT 1/2 1-1/8 1-1/8 5/8 3 36½ 36½ 81½ 255 46-230B 46-185B EXT 1/2 1-1/8 1-1/8 5/8 3 36½ 36½ 81½ 265 56-245B 56-210B EXT 1/2 1-1/8 1-1/8 5/8 3 54½ 36½ 99½ 306 66-295B 66-245B EXT 1/2 1-1/8 1-1/8 5/8 4 36½ 36 36½ 117½ 353 66-345B 66-280B EXT 1/2 1-1/8 1-1/8 5/8 4 36½ 36 36½ 117½ 368 14-42B 14-37B EXT 1/2 ODS 5/8 ODS 5/8 ODS 5/8 ODS 2 19 27½ 42 24-84B 24-72B EXT 1/2 7/8 7/8 5/8 2 37 45½ 49 24-105B 24-85B EXT 1/2 7/8 7/8 5/8 2 37 45½ 55 34-130B 34-105B EXT 1/2 7/8 7/8 5/8 2 55 63½ 79 44-170B 44-140B EXT 1/2 7/8 1-1/8 5/8 3 36½ 36½ 81½ 251 54-215B 54-180B EXT 1/2 1-1/8 1-1/8 5/8 3 54½ 36½ 99½ 299 64-255B 64-215B EXT 1/2 1-1/8 1-1/8 5/8 4 36½ 36 36½ 117½ 340 15 12 5/8 1/2 nstallation Notes: (1) nstall 12 away from back wall. (2) Drain connection on HTA and HTE units are centered on drain pan, and on the left end (facing air discharge) on hot gas defrost units. (3) or long air throw requirements, specify high throw fan guard. (4) Unit height at drain end of hot gas models is as follows: 1,2, and 3 fan models = 15-7/8, 4,5, and 6 fan models = 16-1/4. 2 1/2 1/2 x 1" MTG SLOTS 2 3/4 3/4 MT DRAN 11 1/2 1 1/4 LQ AND HG CONN KNOCKOUTS (3) BACK AND (3) TO W 3 1/4 A B C 5 1/4 13 1/4 15 1/4 ELECTRCAL KNOCKOUTS (4) BACK AND (3) TO DRAN - HOT GAS DRAN - HTA, HTE UNTS 6 SUCTON CONN 3 1/8

Electric Defrost Kits Model Number All-Temp²B 1 Unit Cooler er System 2 Unit Coolers er System 3 Unit Coolers er System 230V 460V 230V 460V 230V 460V HTE16-36B ED-10 ED-12 ED-20* ED-22 ED-30 ED-32 HTE16-41B ED-10 ED-12 ED-20* ED-22 ED-30 ED-32 HTE16-46B ED-10 ED-12 ED-20* ED-22 ED-30 ED-32 HTE26-60B ED-10 ED-12 ED-20* ED-22 ED-30 ED-32 HTE26-75B ED-10 ED-12 ED-20* ED-22 ED-30 ED-32 HTE26-92B ED-10 ED-12 ED-20* ED-22 ED-30 ED-32 HTE36-120B ED-10 ED-12 ED-20* ED-22 ED-33 ED-32 HTE36-140B ED-10 ED-12 ED-20* ED-22 ED-33 ED-32 HTE46-164B ED-10 ED-12 ED-23* ED-22 ED-35 ED-32 HTE46-185B ED-10 ED-12 ED-23* ED-22 ED-35 ED-32 HTE56-210B ED-11 ED-12 ED-23* ED-22 ED-35 ED-34 HTE66-245B ED-11 ED-12 ED-23* ED-22 ED-35 ED-34 HTE66-280B ED-11 ED-12 ED-23* ED-22 ED-35 ED-34 HTE14-37B ED-10 ED-12 ED-20* ED-22 ED-30 ED-32 HTE24-72B ED-10 ED-12 ED-20* ED-22 ED-30 ED-32 HTE24-85B ED-10 ED-12 ED-20* ED-22 ED-30 ED-32 HTE34-105B ED-10 ED-12 ED-20* ED-22 ED-33 ED-32 HTE44-140B ED-10 ED-12 ED-23* ED-22 ED-35 ED-32 HTE54-180B ED-11 ED-12 ED-23* ED-22 ED-35 ED-34 HTE64-215B ED-11 ED-12 ED-23* ED-22 ED-35 ED-34 Electric defrost kits consist of components that are necessary to control the defrost cycle. The optional kits are available as a factory installed option when ordered with a condensing unit. Not all Ed-Kits are available for all condensing unit models. The contents of each kit is described below, along with the function of each component. * - 1/2 through 3 H models require ED-210 or ED-213. Electric Defrost Kits KT NO. TMER AUXLARY SWTCH BLOCK-OUT RELAY DEROST CONTACTOR AN CONTACTOR SEQUENCNG RELAY ED10-230/1 1 1-30A ED11-230/3 1 1 1-30A ED12-460/3 1 1 1-30A 1-25A ¹ED210-230/1 1 1-30A ¹ED213-230/1 1 1 1-50A ¹ED213-230/3 1 1 1-50A ED20-230/1 1 1-30A 2 ED22-460/3 1 1 2-15A 1-25A 2 ED23-230/1 1 1 2-25A 2 ED23-230/3 1 1 2-25A 2 ED30-230/1 1 1-30A 3 ED32-460/3 1 1 3-10A 1-25A 3 ED33-230/1 1 1 3-16A 3 ED34-460/3 1 1 3-16A 1-25A 3 ED35-230/1 1 1 3-33A 3 ED35-230/3 1 1 3-33A 3 Timer: nitiates the defrost cycle. Also used as a override protection for defrost termination. Auxiliary Switch: s mounted on the compressor contactor and prevents the defrost contactor from operating whenever the compressor is energized. Block-Out Relay: Serves the same function as auxiliary switch. Used when defrost contactor is not required (lower wattage single phase only). Defrost Contactor: Carries amperage load for heaters. an Contactor: Used with 460V motors or when 230V motors are wired 3 phase. Sequencing Relays: rovides interconnection of multiple unit coolers on a single system so that each unit cooler is allowed to individually terminate defrost on temperature. ¹ or use with 2 evaporators, 1/2 through 3 H R-series systems ONLY! 7

1/2 Through 80 H COMLETE RERGERATON ACKAGES AR DEROST ELECTRC DEROST HOT GAS DEROST SERRA HGH SERRA CONTACT YOUR HTG RERESENATVE OR DETALS All-Temp²B Low rofile Unit coolers nter-temp Medium rofile Unit Coolers Ultra-Temp High Capacity Warehouse Unit Coolers MiniCon Cond. units 1/2-6 H D-Series Condensing Units 3-22 H V-Series Condensing Units 20-30 H Visit us on the Web: www.russellcoil.com 221 S. Berry St.,.O. Box 1030, Brea, CA 92822-1030 Tel: (714) 529-1935 ax: (714) 529-7203