Product Data 58VMR FEATURES/BENEFITS THE LATEST IN OIL FURNACE TECHNOLOGY

Similar documents
Product Data. 58VLR LOW --- BOY OIL FURNACE INPUT RATES: 70,000 thru 154,000 BTUH SERIES VLR FEATURES/BENEFITS

Product Data 58CMA FEATURES/BENEFITS THE LATEST IN OIL FURNACE TECHNOLOGY

Product Data. 58CMA MULTIPOISE OIL FURNACE INPUT RATES: 70,000 thru 154,000 BTUH SERIES CMA FEATURES/BENEFITS

Product Data 369AAN FEATURES/BENEFITS THE LATEST IN OIL FURNACE TECHNOLOGY

Product Data. 58CMA Multipoise Oil Furnace. Series 120 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Product Data. 58CMA Multipoise Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Product Data. S Unit may also be sidewall vented with an approved A S OVM units equipped with ECM 2.3 Variable Speed

Product Data. 58CLA Low-Boy Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Product Data. 367AAN Low --- Boy Oil Furnace Input Capacities: 70,000 thru 154,000 BTUH Series E 367AAN FEATURES/BENEFITS

Product Data. S UTEC ignition control and fan timer board provide. S S Cabinet features an insulated enclosure for the burner

Product Data OBM/OVM. MULTIPOISE OIL FURNACE INPUT CAPACITIES 70,000 thru 154,000 BTUH THE LATEST IN OIL FURNACE TECHNOLOGY

Product Data. S Unit may also be sidewall vented with an approved A S OVL units equipped with optional ECM 2.3 Variable

Product Data. CBLAAA LOW-BOY OIL FURNACE INPUT RATES: 70,000 thru 154,000 BTUH SERIES 140

Product Data. ama. 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces. 58BLA Low-Boy. Copyright 1996 Carrier Corporation

Product Data. 58PAV Energy-Efficient Induced-Combustion Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh. 80% AFUE At Budget Price

Product Data. 58WAV WeatherMaker 8000 Energy-Efficient Deluxe Upflow Furnace. Series 150 and 160 Input Capacities: 45,000 thru 155,000 Btuh

Product Data. 58TUA WeatherMaker 8000TS with Comfort Heat Technology Upflow Furnace. Series 120 Input Capacities: 40,000 thru 135,000 Btuh

Product Data. 58TUA WeatherMaker 8000TS with Comfort Heat Technology Deluxe Upflow Furnace

Product Data. 58STA/STX WAY MULTIPOISE INDUCED --- COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 140, 150

Product Data. FH4C Base Series Fan Coil Sizes 001 thru 004 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

Product Data. 58STA/STX WAY MULTIPOISE INDUCED --- COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 160

Product Data. 58RAV High-Efficiency Downflow/Horizontal Induced-Combustion Gas Furnace. 80% AFUE At Budget Price

Product Data. S HYBRID HEAT Dual Fuel System compatible S All models are chimney friendly when used with accessory vent kit

Product Data STANDARD FEATURES

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat

Product Data. S Noise elimination combustion system. S Compact design only 33-1/3 in. (846 mm) tall

Product Data. S QuieTecht noise reduction system. S SmartEvapt -Humidity control when using a Thermidistat Control

Product Data. S ECM Blower Motor included S QuieTecht noise reduction system S SmartEvapt Humidity control when using a Thermidistatt Control

Product Data. 58MCA 4-Way Multipoise Fixed-Capacity Direct-Vent Condensing Gas Furnace Series 131 Input Capacities: 40,000 thru 120,000 Btuh

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

395CAV Sizes 045 thru 155 Series H and J

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

Product Data PG9MXA 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE

Product Data. 58MCA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 111 Input Capacities: 40,000 thru 120,000 Btuh

Wt. Lbs Model Number (BTUH) Hz

Product Data. 58MVP Deluxe 4-Way Multipoise Variable-Capacity Condensing Gas Furnace. Series 121 Input Capacities: 40,000 thru 120,000 Btuh

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE

Product Data. 58MSA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 110 Input Capacities: 40,000 thru 120,000 Btuh

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

Model PG9MAB MULTIPOISE CONDENSING GAS FURNACE SS-PG9MAB-01. Time Roman FEATURES. burners seldom, if ever, needs cleaning.

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

Product Data. FB4B Base Series Fan Coil Sizes 024, 036, 048 and 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

Submittal Data 558F SINGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNITS NOMINAL TONS DESCRIPTION FEATURES

Product Data. 58CVA/CVX INFINITY 80 VARIABLE SPEED 4---WAY MULTIPOISE GAS FURNACE Input Capacities: 70,000 thru 155,000 Btuh Series 160

PREMIUM OIL Furnaces. Variable Speed Option. Up to 87.5% Efficiency Optional Cooling Up to 4 Tons High-Grade Stainless Steel Heat Exchanger FEATURING

355MAV Sizes 040 thru 120 Series E

58CTA/CTX PERFORMANCE 80 TWO --- STAGE WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 140

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

Product Data. Comfort Heatt technology, the ultimate in heating comfort...

Product Data. Infinity 96 Model 58MVB Deluxe 4-Way Multipoise Variable-Speed Condensing Gas Furnace. Series 100 Input Rates: 40,000 thru 120,000 Btuh

Product Data. 58MXA Deluxe 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace. Series 111 Input Capacities: 40,000 thru 120,000 Btuh

T9MPV SmartComfort VS90 Product Specifications

Product Data. 58GFA High-Efficiency Induced-Combustion Upflow Furnace. Heating Inputs: 65, ,000 Btuh

Cooling Capacity CFM in. w.c. (125 Pa)

TSTAT0201CW Recommended (sold separately)

Cooling Capacity CFM in. w.c. (125 Pa)

Product Data. IdealComfortt technology, the ultimate in heating comfort...

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

TSTAT0101SC Recommended. Cooling Capacity CFM in. w.c. (125 Pa)

Product Data. S Noise elimination combustion system. S Compact design only 33-1/3 in. (846 mm) tall

MERIT SERIES Downflow

Product Data. 58STA/STX 4-WAY MULTIPOISE INDUCED-COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh THE CARRIER 58STA/STX GAS FURNACE

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

ELITE SERIES Downflow - High Efficiency Blower Motor

Product Data. 59TP5A Performance Boost Two---Stage Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY*

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

Cooling Capacity CFM in. w.c. (125 Pa)

Product Data. FY4A, FA4C Base Series Fan Coil Sizes 018 Thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

Cooling Capacity CFM range

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

Product Data. 59TN6A InfinityR Two---Stage, Variable Speed Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY*

TSTAT0101SC Recommended (order separately)

TECHNICAL SPECIFICATIONS

Product Data. 59SP5A Performance Boost, Single---Stage Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY*

Product Data. 59MN7A Infinityr Modulating Way Multipoise Condensing Gas Furnace Series 100

SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

PLUS 95st MODEL 355CAV DELUXE 4 -WAY MULTIPOISE VARIABLE -SPEED MULTI -STAGE CONDENSING GAS FURNACE Series 100 Input Rates: 60,000 thru 120,000 Btuh

XV80i. Upflow/Horizontal 80% 2-Stage, Variable Speed Gas-Fired Furnace with Whole House Air Cleaner PUB. NO

Product Data. 340AAV 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Sizes 040 thru 140

Product Data. 58MEC PERFORMANCE BOOST WAY MULTIPOISE STAGE CONDENSING GAS FURNACE Input Rates: 60,000 thru 120,000 Btuh

8+* Bulletin No November 1997

RGE 13 A T - 1 A

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE 3 -PASS PRIMARY HEAT EXCHANGERS FLOW -THROUGH SECONDARY HEAT EXCHANGERS MONOPORT INSHOT BURNERS

350MAV HIGHLY-EFFICIENT 4-WAY MULTIPOISE FIXED-CAPACITY DIRECT-VENT CONDENSING GAS FURNACE. Sizes 040 thru 140 Series D. Form No. PDS 350M.40.

RE9X Series Downflow, Upflow Electric Furnaces

Product Data PF4MNP FAN COIL SIZES 018 THRU 060 STANDARD FEATURES AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data. ERVCCLHA Energy Recovery Ventilators

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Product Data. FB4C Base Series Fan Coil Sizes 018 thru 060 AIR HANDLER TECHNOLOGY AT ITS FINEST

Product Data. FE4A, FE5A Infinityt Series Communicating Variable---Speed Fan Coil Puronr Refrigerant Sizes 002 thru 006

T9MPV. 2- Stage Variable Speed 90. Flexibility. Comfort. Efficiency. Quality. Service (05/2006)

H9MPV. 2- Stage Variable Speed 90. Flexibility. Quality. Comfort. Efficiency. Service (7/2004)

TECHNICAL SPECIFICATIONS

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Gas Furnaces. Gas Furnaces. 2-Stage Variable-Speed. 2-Stage Multi-Speed Multipoise. Multipoise 80AFUE. 2-Stage Variable-Speed Multi-Speed Multipoise

Transcription:

Multipoise Oil Furnace Input Capacities: 70,000 thru 154,000 Btuh eries 110 Product Data THE LATET IN OIL FURNACE TECHNOLOGY A06625 The model combines variable -speed high efficiency and quiet operation with the latest oil heating technology. The is available in 2 sizes. Each size can be fired at 3 different rates by a simple nozzle change. Unit 105 covers input ranges from 70,000 to 105,000 Btuh. Unit 120 covers input ranges from 119,000 to 154,000 Btuh. The furnace design is a multipoise style for upflow, donwflow, and horizontal applications. The components of the are the finest in the industry. The unit uses a Riello oil burner with an electronic air damper. The is a standard part of a quality -built home. This energy efficient furnace will provide years of quality service to home builders and homeowners alike. As with other Carrier furnaces, this model is designed to work as part of a total home comfort system which includes elements for cooling, air cleaning, humidification, ventilation, and zoning. FEATURE/BENEFIT Riello Oil Burner High quality Riello oil burner allows safe and efficient combustion of oil. Casing Made of 20 gauge powder painted steel for years of durability and attractiveness. Cabinet features a reversible door, ensuring ease of service access even in downflow applications. Insulation and oundproofing Unique silencer baffle along with insulated walls and rubber blower mounts efficiently captures most combustion noise and vibrations and makes this unit one of the quietest on the market. Combustion Products Venting Top or side flue outlets. Unit may be vented using Type L vent material and a factory -built metal or masonry chimney. Unit may also be sidewall vented with an approved power venter. Variable peed Blower Variable speed blower for precise airflow selection of heating or cooling operation. Electronic Fan Control Electronic fan control board provides reliable operation and easy connection of thermostat and accessory wiring. Combustion Chamber/Heat Exchanger Certifications Composed mainly of stainless and aluminized steel, the unique combination combustion chamber/heat exchanger resists corrosion, overheating, and deterioration. Heat transfer properties make it energy efficient. All seams are tightly welded for leak -free operation. unit is CA certified. The efficiency is GAMA efficiency rating certified. 1

W1 W2 HEAT COOL A A ON OFF B ON OFF B OFF ON C OFF ON C ON ON D ON ON D ON ON W1 W2 OFF OFF W3 W4 ADJ DELAY A A ON OFF B ON OFF B OFF ON C OFF ON C ON ON D ON ON D ON ON OFF W3 OFF P1 R14 LED7 GRN JW5 R2 W4 JW7 R12 D17 D18 D19 R1 D6 D7 D8 D9 D10 D11 D12 D14 JW6 JW3 JW4 120 VAC D20 JW1 LED4 LED3 LED5 LED7 LED8 LED1 R3 C2 U2 R23 R13 LED RED D21 D1 D3 D15 D16 JW2 01 D13 D02 D04 U1 C1 R22 KJ P3 C Warranties Limited Lifetime Warranty on combustion chamber/ heat exchanger. Five-year Warranty on Riello burner and remaining components. Contact your dealer for details. 120 VAC NEUTRAL HUM P2 24 VAC 1 2 OFF OFF 1 2 OFF OFF F1 1 2 OFF OFF 1 2 OFF OFF R21 GRN R20 MO V1 GRN GRN GRN GRN GRN HC 1 1168-83-1 COMBUTION CHAMBER/ HEAT EXCHANGER A97246 Y Y/Y2 G DH O W R C NOTE 1. The Red LED to the right of P-1 will illuminate whenever the limit switch is open. 2. The Green LED below the left end of P-1 will flash when the blower motor is operating. The LED will flash one time for each 100 RPM. 3. The Green LEDs above Y1, Y/Y2, G, O, and W will illuminate whenever there is a 24V input from the thermostat. 4. The Green LED above DH will illuminate whenever there is not a 24VAC input applied. CONTROL CENTER A96370 MODEL NUMBER NOMENCLATURE 105 110 12 Variable peed Riello Burner Multipoise Oil Furnace Cooling ize Airflow (Nominal 400 CFM per 12,000 Btuh Cooling) 12 --- 1200 CFM Input Capacity 105 --- 70,000 Btuh with 0.40 gph nozzle 91,000 Btuh with 0.50 gph nozzle 105,000 Btuh with 0.65 gph nozzle 120 --- 119,000 Btuh with 0.75 gph nozzle 140,000 Btuh with 0.85 gph nozzle 154,000 Btuh with 1.00 gph nozzle eries ama 2

5 6 7 8 4 3 9 2 1 10 11 EE NOTE: 13, 14 Left side, right side, or bottom. 12 A97244 1. Variable speed blower circulates air across the heat exchanger to transfer heat into the home 2. tainless steel combustion chamber/primary heat exchanger 3. Unique silencer system reduces combustion noise 4. Heat exchanger designed and shaped to efficiently transfer heat from furnace into the home 5. Fully insulated internal walls to minimize heat loss 6. upply -air plenum 7. High limit control to prevent overtemperature operation 8. Reversible access door provides easy access to burner and controls 9. High -performance oil burnerreturn -air plenum 10. Adjustable electronic fan control (inside) has low voltage electrical terminal strip for easy connection of thermostat, cooling control, electronic air cleaner, and humidifier 11. Access door to blower 12. Air filter (field supplied) 13. Return -air plenum 3

CLEARANCE TO COMBUTIBLE UNIT APPLICATION UPFLOW (IN.) DOWNFLOW (IN.) HORIZONTAL (IN.) Furnace 0 2 2 IDE upply Plenum and Warm---Air Duct Within 6 Ft of Furnace 1 2 1 BACK Furnace 0 1 0 Furnace Casing or Plenum 2 2 2 TOP Horizontal Warm---Air Duct Within 6 Ft of Furnace 2 2 3 BOTTOM Furnace 0 0* 0* FLUE PIPE Horizontally or Below Pipe 4 4 4 Vertically Above Pipe 9 9 9 FRONT 8 8 24 *For combustible floor, use approved accessory subbase NOTE: Adequate service clearance should be provided over and above these dimensions as required. PHYICAL DATA UNIT IZE 105---12 120---20 INPUT (BTUH) 70,000 91,000 105,000 119,000 140,000 154,000 HEATING CAPACITY* 57,000 74,000 85,000 99,000 115,000 127,000 NOZZLE 0.40 --- 70A 0.50 --- 70W 0.65 --- 70W 0.75 --- 70B 0.85 --- 70W 1.00 --- 70W FIRING RATE (GPH){ 0.50 0.65 0.75 0.85 1.00 1.10 AFUE% UPFLOW 82 82 81.5 83 83 82.5 DOWNFLOW 82 82 81.5 83 82.5 82.5 HORIZONTAL 82 82 82 83 82.5 82 OIL PUMP TAGE/PREURE (PIG) 1/160 1/170 1/135 1/130 1/140 1/125 HEATING TEMP RIE _F 55---85 55---85 55---85 55---85 55---85 55---85 HIPPING WEIGHT (LB) 230 230 230 275 275 275 BURNER MODEL (3450 RPM) RIELLO 40 --- F3 RIELLO 40 --- F3 * Capacity and AFUE in accordance with U.. Government DOE test procedures { For rating purposes only haded cells are as Factory hipped RIELLO 40 --- F3 RIELLO 40 --- F5 RIELLO 40 --- F5 RIELLO 40 --- F5 4

PERFORMANCE DATA UNIT IZE 105---12 120---20 VARIABLE PEED ECM MOTOR 1/2 1 BLOWER WHEEL DIAMETER X WIDTH (In.) 10 x 10 12 x 10 FILTER IZE (In.) --- (Disposable, Field upplied) 16 x 24 or 25 x 1 18x30or20x30x1 ELECTRICAL DATA UNIT IZE 105---12 120---20 UNIT VOLT --- HERTZ --- PHAE 115 --- 60 --- 1 115 --- 60 --- 1 OPERATING VOLTAGE RANGE (Min---Max)* 104 --- 132 104 --- 132 MAXIMUM UNIT AMP 12.2 15.7 MINIMUM WIRE IZE (AWG) 14 12 MAXIMUM WIRE LENGTH (Ft){ 26 26 MAXIMUM FUE IZE OR CKT BKR (Amps)} 15 20 TRANFORMER (24v) 40va 40va EXTERNAL CONTROL POWER AVAILABLE Heating 40va 40va Cooling 30va 30va AIR CONDITIONING RELAY tandard tandard * Permissible limits of the voltage range at which the unit will operate satisfactorily { Length is as measured one way along wire path between unit and service panel for maximum 2% voltage drop } Time---delay fuse type is recommended 5

IZE 105 AIRFLOW DATA (CFM) W1 --- HEAT *A (1=OFF,2=OFF)*** * B (1 = ON, 2 = OFF)*** C (1=OFF,2=ON)** D(1=ON,2=ON) HEAT INPUT (UGPH) 0.75 0.65 0.50 OIL HEATING MODE 24 VAC INPUT (R) ON W ONLY 1128 1146 1146 842 1275 1295 1295 951 959 974 974 716 894 951 969 823 1010 1075 1095 930 760 808 824 700 733 779 769 757 858 880 869 855 623 662 654 643 AME VALUE A A DIP WITCH POITION CONTINUOU FAN 24 VAC INPUT (R) ON G ONLY A/C IZE (TON) 690 739 729 711 *A 3.0 759 813 802 782 (1=OFF,2=OFF)*** 621 665 656 640 600 613 609 592 * B 2.5 660 674 670 651 (1 = ON, 2 = OFF)*** 540 552 548 533 505 513 505 483 C 2.0 556 564 556 531 (1=OFF,2=ON)** 455 462 455 435 D(1=ON,2=ON)* 441 434 417 410 D(1=ON,2=ON)** 1.5 485 477 459 451 D (1 = ON, 2 = ON)*** 397 391 375 369 COOLING OR HEAT PUMP HEATING MODE---INGLE PEED OR 2---PEED HIGH 24 VAC INPUT (R) ON Y/Y2 AND O (FOR COOLING) A/C IZE (TON) 918 973 973 827 * 3.0 1010 1070 1070 910 ** 826 876 876 744 752 798 798 795 * 2.5 827 878 878 875 ** 677 718 718 716 620 658 650 631 2.0 682 724 715 694 558 592 585 568 D(1=ON,2=ON)* 509 520 506 497 D(1=ON,2=ON)** 1.5 560 572 557 547 D (1 = ON, 2 = ON)*** 458 468 455 447 NOTE: In cooling---dehumidification mode, with no 24VAC input to DH, the CFM is reduced 15% 6

IZE 105 AIRFLOW DATA (CFM) continued * ** * ** D(1=ON,2=ON)* D(1=ON,2=ON)** D (1 = ON, 2 = ON)*** COOLING OR HEAT PUMP HEATING MODE---2---PEED LOW 24 VAC INPUT (R) ON Y1 AND O (FOR COOLING) A/C IZE (TON) 546 552 544 530 3.0 601 607 598 583 491 497 490 477 485 488 482 463 2.5 534 537 530 509 437 439 434 417 434 421 413 404 2.0 477 463 454 444 391 379 372 364 372 370 364 339 1.5 409 407 400 373 335 333 328 305 NOTE: In cooling---dehumidification mode, with no 24VAC input to DH, the CFM is reduced 15%. DELAY PROFILE FOR OIL HEATING MODE W4 --- DELAY HEAT INPUT (UGPH) PreRun On --- Delay CFM Level --- Time hortrun On --- Delay CFM Level --- Time Off --- Delay CFM Level --- Time** A(1=OFF,2=OFF) 0.75 13% --- 45 sec. 19% --- 30 sec 38% --- 3 min. B (1 = ON, 2 = OFF) 0.65 13% --- 45 sec. 19% --- 60 sec 38% --- 3 min. C(1=OFF,2=ON) 0.5 13% --- 60 sec. 13% --- 60 sec 38% --- 3 min. D(1=ON,2=ON) All 13% --- 30 sec. 100% --- 0 sec 100% --- 2 min. DELAY PROFILE FOR COOLING OR HEAT PUMP HEATING MODE No adjustment PreRun On --- Delay hortrun On --- Delay Off --- Delay A/C size required CFM --- Level --- Time CFM Level --- Time CFM Level --- Time All 13% --- 30 sec. 75% --- 2.5 min. 50% --- 3 min. * CFM with W3---ADJ Dip witch A Position ** CFM with W3---ADJ Dip witch B Position *** CFM with W3---ADJ Dip witch C Position { PreRun is the time with 0 CFM after the call for cooling or heating. The hortrun come after the PreRun. } hortrun is the time before the blower starts at normal speed, with very low CFM, to minimize cool draft in the air distribution system. {{ Off---delay is the time required to cool down the coil (heating mode) with low CFM, to minimize cool draft in the air distribution system. 7

IZE 105 POWER DRAW (WATT) W1 --- HEAT HEAT INPUT (UGPH) OIL HEATING MODE 24 VAC INPUT (R) ON W ONLY POWER DRAW (WATT) A(1=OFF,2=OFF) 0.75 285 395 467 371 B (1 = ON, 2 = OFF) 0.65 160 275 343 363 C(1=OFF,2=ON) 0.50 109 203 258 307 D(1=ON,2=ON) AME VALUE A A DIP WITCH POITION * NOTE: W3---ADJ set in witch position A. A/C IZE (TON) CONTINUOU FAN 24 VAC INPUT (R) ON G ONLY POWER DRAW (WATT) A(1=OFF,2=OFF) 3.0 100 189 244 291 B (1 = ON, 2 = OFF) 2.5 81 155 196 235 C(1=OFF,2=ON) 2.0 63 122 159 193 D(1=ON,2=ON) 1.5 55 104 130 172 * NOTE: W3---ADJ set in witch position A. COOLING OR HEAT PUMP HEATING MODE---INGLE PEED OR 2---PEED HIGH 24 VAC INPUT (R) ON Y/Y2 AND O (FOR COOLING) A/C IZE (TON) POWER DRAW (WATT) A(1=OFF,2=OFF) 3.0 178 290 350 373 B (1 = ON, 2 = OFF) 2.5 115 210 270 333 C(1=OFF,2=ON) 2.0 86 166 208 251 D(1=ON,2=ON) 1.5 64 121 160 193 * NOTE: W3---ADJ set in witch position A. A/C IZE (TON) COOLING OR HEAT PUMP HEATING MODE---2---PEED LOW 24 VAC INPUT (R) ON Y1 AND O (FOR COOLING) POWER DRAW (WATT) A(1=OFF,2=OFF) 3.0 69 135 171 212 B (1 = ON, 2 = OFF) 2.5 57 116 153 189 C(1=OFF,2=ON) 2.0 54 98 134 170 D(1=ON,2=ON) 1.5 47 88 124 151 * NOTE: W3---ADJ set in witch position A. 8

IZE 120 AIRFLOW DATA (CFM) OIL HEATING MODE 24 VAC INPUT (R) ON W ONLY W1 --- HEAT * ** * B (1 = ON, 2 = OFF)*** C (1=OFF,2=ON)** D(1=ON,2=ON) HEAT INPUT (UGPH) 0.85 1.00 1.10 1417 1417 1417 1407 1601 1601 1601 1590 1204 1204 1204 1196 1674 1666 1658 1658 1892 1883 1874 1874 1423 1416 1409 1409 1826 1826 1826 1813 2063 2063 2063 2049 1552 1552 1552 1541 AME VALUE A A DIP WITCH POITION * ** * ** D(1=ON,2=ON)* D(1=ON,2=ON)** D (1 = ON, 2 = ON)*** A/C IZE (TON) 5.0 4.0 3.5 3.0 CONTINUOU FAN 24 VAC INPUT (R) ON G ONLY 1243 1259 1259 1251 1367 1385 1385 1376 1119 1133 1133 1126 989 995 977 959 1088 1095 1075 1055 890 896 879 863 871 871 843 831 958 958 927 914 784 784 759 748 773 741 741 705 850 815 815 776 696 667 667 635 COOLING OR HEAT PUMP HEATING MODE---INGLE PEED OR 2---PEED HIGH 24 VAC INPUT (R) ON Y/Y2 AND O (FOR COOLING) A/C IZE (TON) 1738 1738 1733 1725 * 5.0 1912 1912 1912 1898 ** 1564 1564 1564 1553 1333 1352 1352 1342 * 4.0 1466 1487 1487 1476 ** 1200 1217 1217 1208 1154 1154 1145 1118 3.5 1269 1269 1260 1230 1037 1039 1031 1006 D(1=ON,2=ON)* 992 997 974 974 D(1=ON,2=ON)** 3.0 1091 1097 1071 1071 D (1 = ON, 2 = ON)*** 893 897 877 877 NOTE: In cooling---dehumidification mode, with no 24VAC unput to DH, the CFM is reduced 15%. 9

IZE 120 AIRFLOW DATA (CFM) continued COOLING OR HEAT PUMP HEATING MODE---2---PEED LOW 24 VAC INPUT (R) ON Y1 AND O (FOR COOLING) A/C IZE (TON) 900 900 881 860 * 5.0 990 990 969 946 ** 810 810 793 774 749 723 717 695 * 4.0 824 795 789 765 ** 674 651 645 626 680 643 617 599 3.5 748 707 679 659 612 579 555 539 D(1=ON,2=ON)* 595 576 539 511 D(1=ON,2=ON)** 3.0 655 634 593 562 D (1 = ON, 2 = ON)*** 536 518 485 460 NOTE: In cooling---dehumidification mode, with no 24VAC unput to DH, the CFM is reduced 15%. DELAY PROFILE FOR OIL HEATING MODE W4 --- DELAY HEAT INPUT (UGPH) PreRun On --- Delay CFM Level --- Time hortrun On --- Delay CFM Level --- Time Off --- Delay CFM Level --- Time** A(1=OFF,2=OFF) 0.85 13% --- 45 sec. 44% --- 30 sec. 38% --- 3 min. B (1 = ON, 2 = OFF) 1.00 13% --- 30 sec. 44% --- 30 sec. 38% --- 3 min. C(1=OFF,2=ON) 1.10 13% --- 30 sec. 50% --- 30 sec. 38% --- 3 min. D(1=ON,2=ON) All 13% --- 30 sec. 100% --- 0 sec. 100% --- 2 min. DELAY PROFILE FOR COOLING OR HEAT PUMP HEATING MODE No adjustment required A/C size PreRun On --- Delay CFM --- Level --- Time hortrun On --- Delay CFM Level --- Time Off --- Delay CFM Level --- Time All 13% --- 30 sec. 75% --- 2.5 min. 50% --- 3 min. * CFM with W3---ADJ Dip witch A Position. **CFM with W3---ADJ Dip witch B Position. ***CFM with W3---ADJ Dip witch C Position. { PreRun is the time with 0 CFM after the call for cooling or heating. The hortrun come after the PreRun. } hortrun is the time before the blower starts at normal speed, with very low CFM, to minimize cool draft in the air distribution system. {{ Off---Delay is the time required to cool down the coil (heating mode), with low CFM, to minimize cool draft in the air distribution system. 10

IZE 120 POWER DRAW (WATT) W1 --- HEAT HEAT INPUT (UGPH) OIL HEATING MODE 24 VAC INPUT (R) ON W ONLY POWER DRAW (WATT) A(1=OFF,2=OFF) 0.85 356 474 565 636 B (1 = ON, 2 = OFF) 1.00 557 683 786 883 C(1=OFF,2=ON) 1.10 710 870 983 1074 D(1=ON,2=ON) AME VALUE A A DIP WITCH POITION * NOTE: W3---ADJ set in witch position A. A/C IZE (TON) CONTINUOU FAN 24 VAC INPUT (R) ON G ONLY POWER DRAW (WATT) A(1=OFF,2=OFF) 5.0 264 382 463 532 B (1 = ON, 2 = OFF) 4.0 158 258 313 366 C(1=OFF,2=ON) 3.5 125 208 249 305 D(1=ON,2=ON) 3.0 105 165 218 258 * NOTE: W3---ADJ set in witch position A. COOLING OR HEAT PUMP HEATING MODE---INGLE PEED OR 2---PEED HIGH 24 VAC INPUT (R) ON Y/Y2 AND O (FOR COOLING) POWER DRAW (WATT) A/C IZE (TON) A(1=OFF,2=OFF) 5.0 611 750 837 945 B (1 = ON, 2 = OFF) 4.0 312 441 527 596 C(1=OFF,2=ON) 3.5 223 322 397 449 D(1=ON,2=ON) 3.0 168 256 309 372 * NOTE: W3---ADJ set in witch position A. COOLING OR HEAT PUMP HEATING MODE---2---PEED LOW 24 VAC INPUT (R) ON Y1 AND O (FOR COOLING) POWER DRAW (WATT) A/C IZE (TON) A(1=OFF,2=OFF) 5.0 133 223 268 320 B (1 = ON, 2 = OFF) 4.0 98 162 209 252 C(1=OFF,2=ON) 3.5 89 142 184 220 D(1=ON,2=ON) 3.0 73 129 165 194 * NOTE: W3---ADJ set in witch position A. 11

PULL DIMENION A TOP KNOCK-OUT FOR J DIAM VENT 19 20 3 E G KNOCK-OUT BOTH IDE FOR J DIAM VENT 19 VENT CONN C B OIL INLET (BOTH IDE) 2 L H ELECTRICAL CONNECTION (BOTH IDE).88 DIAM TYP D F K 20 A98037 DIMENION (IN.) UNIT IZE A B C D E F G H J K L 105---12 35 48---3/4 31---1/4 16---5/8 20 22 12 14 5 1 --- 1/2 1 --- 3/4 120---20 39---1/2 53 33---1/4 18---3/4 24 28 12---19/32 16 6 1 --- 5/8 1 --- 1/2 12

ACCEORIE A97432 CONTROL: THERMOTAT AND ZONING Available in programmable and non---programmable models, Carrier thermostats maintain a constant, comfortable temperature level in the home. For the ultimate in home comfort, Carrier s 2, 4, and 8---zone systems allow temperature control of individual zones of the home. This is accomplished through a series of electronic dampers and remote room sensors. The 4---zone system is shown. ENERGY/HEAT RECOVERY VENTILATOR A94336 Carrier s energy or heat recovery ventilators exhaust stale indoor air and provide fresh outdoor air to the home while minimizing heat loss and humidity level. Especially useful for today s tighter constructed houses. Energy recovery ventilator is shown. A97380 ELECTRONIC OR MECHANICAL AIR CLEANER Cleans the air of smoke, dirt, and many pollens commonly found. aves decorating and cleaning expenses by keeping carpets, furniture, and drapes cleaner. Electronic air cleaner is shown. HUMIDIFIER A91365 By adding moisture to winter--- dry air, Carrier humidifier can often improve comfort and keeps woodwork, wallpaper, and paint in better condition. Moisturizing household air also helps to retain normal body heat and provides comfort at lower temperatures. FURNACE ACCEORIE KLAB0601DET Downflow ubbase Kit --- Required for combustible floors KLAB0701DET Horizontal ubbase Kit --- Required for combustible floors KLABV0101DET Blocked Vent hutoff Kit KLADC0101DET Downflow Conversion/Vent Guard --- Required for downflow operation, Model 105--- 12 KLADC0201DET Downflow Conversion/Vent Guard --- Required for downflow operation, Model 120--- 20 TTATCCPHH01---B TTATCCPRH01--- B TTATCCPAC01--- B TTATCCPHP01--- B TTATCCP201--- B TTATCCPRF01 TTATCCPF701 TTATCCNAC01--- C TTATCCNHP01--- C TTATCCN201--- C ZONECC2KIT01--- B ZONECC4KIT01--- B ZONECC8KIT01--- B EACBAXCC0014 EACBAXCC0020 EACBAXCC2020 HUMCCBP2312 HUMCABP2312 HUMCCLBP2317 HUMCALBP2317 HUMCCLFP1318 HUMCALFP1318 HRVCCHA1100 HRVCCVA1100 HRVCCLHA1150 HRVCCLHA1250 HRVCCVU1150 HRVCCVU1200 HRVCCLVU1150 HYBRID HEAT/THERMIDITAT CONTROL Hybrid Heat Thermostat, Programmable, Outdoor Temperature ensor Included Thermidistat Control --- Non--- Programmable/Programmable Thermostat with Humidity Control. PROGRAMMABLE THERMOTAT ELECTION Thermostat, Auto Changeover, 7--- Day Programmable, F/ C, 1 --- tage Heat/1 --- tage Cool Thermostat, Auto Changeover, 7--- Day Programmable, F/ C, 2 --- tage Heat/1 --- tage Cool Thermostat, Auto Changeover, 7--- Day Programmable, F/ C, 2 --- tage Heat/2 --- tage Cool in AC, 3 --- tage Heat/2---tage Cool in HP mode Thermostat, Auto Changeover, 7---Day Programmable, F/ C, Wireless Transmitter Thermostat, Auto Changeover, 7---Day Programmable, F/ C, Flatstat NON---PROGRAMMABLE THERMOTAT ELECTION Thermostat, Auto Changeover, Non--- Programmable, F/ C, 1 --- tage Heat/1 --- tage Cool Thermostat, Auto Changeover, Non--- Programmable, F/ C, 2 --- tage Heat/1 --- tage Cool Thermostat, Auto Changeover, Non--- Programmable, F/ C, 2 --- tage Heat/2 --- tage Cool in AC, 3 --- tage Heat/2---tage Cool in HP mode ZONING CONTROL ELECTION Comfort Zone II--- B --- 2 Zone Kit/Temperature and Humidity Control Comfort Zone II--- B --- 4 Zone Kit/Temperature and Humidity Control Comfort Zone II--- B --- 8 Zone Kit/Temperature and Humidity Control HEALTHY HOME OLUTION Electronic Air Cleaner --- 120V, 1400 CFM Electronic Air Cleaner --- 120V, 2000 CFM Electronic Air Cleaner --- 240V, 2000 CFM Humidifier --- 12 g./day, 24V tandard, mall Bypass Humidifier --- 12 g./day, 24V Automatic, mall Bypass Humidifier --- 17 g./day, 24V tandard, Large Bypass Humidifier --- 17 g./day, 24V Automatic, Large Bypass Humidifier --- 18 g./day, 24V tandard, Fan Powered Humidifier --- 18 g./day, 24V Automatic, Fan Powered Heat Recovery Ventilator --- mall Horizontal Unit, 100 CFM Heat Recovery Ventilator --- mall Vertical Unit, 100 CFM Heat Recovery Ventilator --- Large Horizontal Unit, 150 CFM Heat Recovery Ventilator --- Large Horizontal Unit, 250 CFM Heat Recovery Ventilator --- mall Vertical Unit, 150 CFM Heat Recovery Ventilator --- mall Vertical Unit, 200 CFM Heat Recovery Ventilator --- Large Vertical Unit, 150 CFM 13

ACCEORIE (CONT.) HRVCCLVU1200 Heat Recovery Ventilator --- Large Vertical Unit, 200 CFM HRVCCLVU1330 Heat Recovery Ventilator --- Large Vertical Unit, 330 CFM ERVCCHA1100 Energy Recovery Ventilator --- mall Horizontal Unit, 100 CFM ERVCCVA1100 Energy Recovery Ventilator --- mall Vertical Unit, 100 CFM ERVCCLHU1150 Energy Recovery Ventilator --- Large Horizontal Unit, 150 CFM ERVCCLHU1200 Energy Recovery Ventilator --- Large Horizontal Unit, 200 CFM EZXCABCC1016 Media Filter Cabinet --- 1600 CFM (Replacement Filter: EXPXXFIL0016) EZXCABCC1020 Media Filter Cabinet --- 2000 CFM (Replacement Filter: EXPXXFIL0020) TYPICAL INTALLATION AIR CONDITIONER OR HEAT PUMP UPPLY-AIR DUCT A/C COIL OIL TANK RETURN- AIR DUCT VENT PIPE CHIMNEY BAROMETRIC DRAFT DAMPER OIL FURNACE AIR FLOW A98026 Copyright 2007 Carrier Corp. 7310 W. Morris t. Indianapolis, IN 46231 Printed in U..A. Edition Date: 01/07 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Catalog No: ---3PD Replaces: ---2PD 14