Material information. - MediDispenser - Trays - Inlay-dishes - Sliding-lids - MediCups - Cytostatics-blending-cannula

Similar documents
Processing Instructions. Cleaning so easy.

Product- and Environment Data Sheet Page: 1/5 Date: Date of revision:

Cleaning and care guide for material surfaces

Introduction. Contents. Introduction. Introduction Systemised marking A.2. Colour coding with PrintJet ADVANCED A.4. Materials A.6

I.F.U Re/Processing Reusable Medical Devices

A DIVISION OF HOSE & TUBING CATALOG 2017

Guidance on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS) Regulations 2012

9.3. Inks Closures and Liners Recycle- friendly Problematic Handles and Sport Caps Household Chemical PET


Electron Microscopy Sciences

ULTRA DYNAMIC HOSE PRODUCTS HOSE & TUBING CATALOG 2018 A DIVISION OF UBBER MPANY, INC. RUBBER COMPANY, INC RUBBER COMPANY, INC.

1 Intended Use of the Breas HA 01 Humidifier

Operating instructions

APR DESIGN FOR RECYCLABILITY GUIDELINES:


User Guide for Reprocessing of the SUPER VIEW Wide Angle Viewing System Sterilizable Components and Accessories

Electric steam steriliser

User manual. Washing Machine ZWG 6148K

Septic Smart. Septic Care, Odour Control & Cleaning Product Catalogue

OSC... INSTRUCTION MANUAL - KITCHEN EXTRACTOR HOOD

TYPES OF PLASTICS BY NUMBER

IN 900 BIC UK INSTRUCTION MANUAL - KITCHEN EXTRACTOR HOOD

Use & Care Manual Contemporary Electric Fires

USE & CARE MANUAL. ELECTRIC FIREPLACE SUITE (remote control operated) ADI0010 V

7a Fig.1. Fig.3. Fig.2. Fig.4 M0S U01

Corning Storage Bottles Selection and Use Guide

Corning Storage Bottles Selection and Use Guide

AMW 450 AMW 460 AMW 461

Care & Maintenance. Acrylic. Item Description:

VR60 GLASS FROSTERS INSTALLATION AND OPERATING MANUAL PLEASE LEAVE WITH OPERATOR. VR60 Glass Froster. Series 1

Wiring Duct Product Selection Guide

Contents Safety instructions...3

CARE AND MAINTENANCE DOCUMENT FOR KITCHEN FINISHES

analytical laboratory clear amber bottles clear bottles

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

CLEANING AND SANITIZING

Chiller with BP-1 1/2 oz Pump

MW001 Integrated Dishwasher. Manual for Installation, Use and Maintenance

User Manual. Refrigerator ZRG16605WA

User Manual Refrigerator SKS58210F1

FAVORIT34502VIO. EN User Manual

User Manual. Tumble Dryer ZDC8202P

01694-REVC_081315_ENGLISH

Owner & Operator s Manual. Table of Contents

Hygiene within nursing homes, geriatric wards, rehabilitation centres automatic washer disinfectors

BEFORE USING THE WASHING MACHINE

ELECTRONIC WASTE. It is a point of concern considering that many components of such equipment are considered toxic and are not biodegradable.

Record of Amendments. Version Date Amendment Section/page affected

User manual. Washing Machine ZWG K

PD100MF0MPx. Surface Mount Type, Opaque Resin Photodiode. PD100MF0MPx. Agency Approvals/Compliance. Features. Model Line-up.

SAFEGUARDING THE ENVIRONMENT IMPORTANT NOTES BEFORE USING THE OVEN OVEN ACCESSORIES CARE AND MAINTENANCE TROUBLESHOOTING GUIDE AFTER SALES SERVICE

BSF60WH / BSF60SS BUILT IN ELECTRIC FAN OVEN. Instruction Manual. Please read these instructions carefully before use and retain for future reference

Genware Care & Guidance

User manual. Fridge Freezer ZRT18100WA

RAP-hip Hip stem extraction set

Installation instructions. Built-in oven. and User guide NZ AU GB IE. OB60 single & double multifunction models

BEFORE USING THE DISHWASHER/CONNECTIONS

Bar Fridge USER MANUAL MB46W

GETTING STARTED? EASY.

Technical Datasheet. Suction Controllers, Flow Meters & Accessories

Contents. Safety instructions...4. Machines Overview...8. Start-up...9. Preparing beverages Programming cup capacity...11

A. Administrative. B. Technical General

Septic Care & Odour Control

Operating Instructions Wine storage refrigerator 12/

INSTALLATION GUIDE / USER GUIDE GB IE

SAFEGUARDING THE ENVIRONMENT IMPORTANT NOTES BEFORE USING THE OVEN OVEN ACCESSORIES CARE AND MAINTENANCE TROUBLESHOOTING GUIDE AFTER SALES SERVICE

User Manual. Dishwasher ZDM17301SA ZDM17301WA

HOF600SS 60 cm Fan oven HOS600SS 60 cm Static oven

Operating and installation instructions

..the International Leader in Thermoplastic Powders for the Protective Coating of Metals

CONTENTS QUICK REFERENCE GUIDE INSTRUCTIONS FOR USE PROGRAMME CHART BOOKLET

EDH3786GDW. EN Tumble Dryer User Manual

Cordless Water Kettle LD-K3030A User Manual

Care and Maintenance For EcoGranit sinks

2 WOW MOP COMPONENTS. Spray Button Power Button Nozzle. Pad Attach (Shadowed Area) Handle. Reservoir. Base

ARVS Equipments Private Limited

HULME MARTIN HEAT SEALERS

GETTING STARTED? EASY.

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

User Manual. Hob PH601SS

Built-in Conventional oven

Product Care and Maintenance Information

ELECTRIC WALL HANGING FIREPLACE SUITE FUI0005_V2_ USE & CARE MANUAL

TOWN OF MENOMINEE ORDINANCE NO.62

User s Guide ENGLISH. Other languages available on our website:

ANTEC SUSTAINABILITY OF PVC (VINYL) PIPE: A COMPREHENSIVE ENVIRONMENTAL REVIEW. May 9, 2017

Bottled Water Dispenser User Manual

LESSON 8: Recycling OVERVIEW

Processing (cleaning, disinfection and sterilization) of instruments from Smith & Nephew Orthopaedics AG

This is a preview - click here to buy the full publication. IEC Quality Assessment System for Electronic Components (IECQ System)

RoHS CERTIFICATE OF COMPLIANCE FOR INTELLITOUCH SUPER FLAT PROFILE SCREENS

GETTING STARTED? EASY.

USE & CARE MANUAL WALL HANGING FIRE. CO9126 V2_110512

MW402 Integrated Dishwasher

USE & CARE MANUAL COMPACT ELECTRIC FIREPLACE SUITE. CO9158 V1_301012

RCB53724MW RCB53724MX RCB53724VW RCB53724VX. User Manual Fridge Freezer USER MANUAL

[en] Instruction manual

Installation, Operation and Maintenance Instructions ThermaFlex Gasketed Plate Heat Exchanger OM010

APR Design Guide for Plastics Recyclability for PET (Polyethylene Terephthalate, Resin Identification Code #1)

CODE OF PRACTICE. No 11 CLEANING OF EQUIPMENT AND PREMISES

Transcription:

information - MediDispenser - Trays - Inlay-dishes - Sliding-lids - MediCups - Cytostatics-blending-cannula

Dispenser Temperature tolerance PS: Polystyrene (food foil, certified) - 40 C to + 60 C (material tests of manufacturer) Fragile, hard, avoid hits The material is light sensitive. Avoid UV-exposure No damages by: acids, alcohol, bases Damages by: oxidants, hydrocarbons, ketone, ester, aldehyde, acetone - Emission free recycling - Very good ecological balance 06 PS Cleaning reference Washable Chemicals Dishwasher Sterilisation with frequent use of caustic solutions, alcohol and acids, the plastic becomes brittle at 55 C (eco-program) without any problem, at 65 C maximum 45 min. running time at 95 C (industrial rinsing machines) 2 min. running time unsuitable 2

Inlay-dish (translucent, coloured) Temperature tolerance PS: Polystyrene (food foil). - 40 C to + 60 C Fragile, hard, avoid hits No damages by: acids, alcohol, bases Damages by: oxidants, hydrocarbons, ketone, ester, aldehyde, acetone - Emission free recycling - Contains no latex, fluorine, cadmium, lead, bromine, chlorine. - Very good ecological balance 06 PS Cleaning reference Washable Chemicals Dishwasher Sterilisation with frequent use of caustic solutions, alcohol and acids, the plastic becomes brittle at 55 C (eco-program) without any problem, at 65 C maximum 45 min. running time at 95 C (industrial rinsing machines) 2 min. running time gas, radioisotopes, (no steam!) 3

MediCups 25 ml one-way cups with millimetre graduation 0543 Temperature Tolerance Tests - PP: Polypropylene - Cup in 5 colours with white cover, translucent - 190 C to + 130 C Malleable, pliable No damages by: acids, alcohol, bases CE marking: class 1 medicinal product without graduation - Emission free recycling - Contains no latex, no cadmium pigments - Very good ecological balance 05 PP Cleaning reference Chemicals with frequent use of caustic solutions, alcohol and acids, the plastic becomes brittle Dishwasher at 55 C (eco-program) without any problem, at 65 C maximum 45 min. running time at 95 C (industrial rinsing machines) 2 min. running time Sterilisation in autoclave 4

Single-use inlay-dish- and blister (transparent) Temperature Tolerance - PET: Polyethyleneterephthalat (suitable for food) - Contains no latex and no softeners - 50 C to + 100 C High consistency, abrasion-proof, deforms by heat - No material damages by alcohol - Damages by: acids, bases, aldehyde, ester, hydrocarbons, oxidants - Emission free recycling - Very goodecological balance Cleaning reference No hot water (Hydrolysis), PET deforms by heat Chemicals Acetone damages the material Dishwasher Not suitable (material deforms) Sterilisation Gas, radio-isotope (no steam!) 5

Sliding-lid (transparent) Temperature Tolerance PET: Polyethyleneterephthalat (suitable for food) max. 40 C High consistency, abrasion-proof, deforms by heat. PET is UV-B, UV-C-FUV, UV-C-VUF, EUV and XUV resistant - No material damages by alcohol - Damages by: acids, bases, aldehyde, ester, hydrocarbons, oxidants - Emission free recycling (contains no bisphenol A or halogen) - Very good ecological balance Cleaning Reference No hot water (Hydrolysis), Sliding-Lid deforms with heat and the brim opens. Clean with luke-warm water and mild detergent. Chemicals Not allowed Dishwasher Not suitable (material deforms) Sterilisation Gas, radio-isotope (no steam!) Peculiarity WIEGAND sliding-lids are humidity-proof (scientifical test in GB). The clamping action originates through elasticity 6

Sliding-lid (transparent) Temperature Tolerance Tests - PVC: Polyvinyl chloride 0.3 mm - Contains no latex and no softeners 20 C to + 55 C hit resistant, pliable - No material damages by alcohol - Damages by: acids, bases, aldehyde, ester, hydrocarbons, oxidants - Printable EU: Requirements about heavy metal content: 94/62/EEC; and guidelines 2002/72/EC DE: Ordinance about material of 23.12.1997; BfR advice II, IX und LII. - Emission free recycling - Very good ecological balance Cleaning Reference Washable Chemicals Dishwasher Sterilisation Alcohol and acids blur the material Acetone damages the material not suitable (material deforms) Gas, radio-isotope (no steam!) Peculiarity WIEGAND sliding-lids are humidity-proof (scientifical test in GB) 7

BlisterBox (translucent) Temperature Tolerance PP: Polypropylene 0.8 mm - Optimal material property by approx. 23 C - Deformation by 70 C, melting point by 120 C - If stored by the freezing point the plastic becomes brittle (put cooled boxes 24-48 hours in room temperature before folding) Peculiarity - Density: 0.91 - Hit- and shock resistant - Pliable, flexible Opacity Environment / - Translucent (white) - Transparency: 75-80 % - Polypropylene is a polymer which reacts in contact with some solvents - Don't use acetone - Water-, fat- and alcohol resistant (emission free) - Emission free recycling, the material is indifferent and nontoxic, very good ecological balance - The product was manufactured in a waterless process - Free of halogens or ozone-depleting substances (FCKW) - It meets comestible-, toys- and CONEG-standards Cleaning Reference Washing with soapsuds, lukewarm water Disinfection with alcohol and standard disinfectants Sterilisation unsuitable 8

Pill processing PillCrusher WIEGAND Article No. 97 Syntethic parts: Polyamid (Akulon K222-D). Does not contain heavy metals cadmium, lead, mercury and chromium IV or PolyBrominated Biphenyl (PBB) or PolyBrominated DiphenylEthers (PBDE). Complies to EC directives 2002/95/EC. No health or environmental hazards known. Mortar: stainless steel Temperature tolerance Temp. of deflection 65 C, melting temperature 220 C Cleaning directives Chemicals usual disinfectants are unproblematic, do not use aggressiv chemicals as Acetone Dishwasher 55 C without hesitation Sterilisation not suitable 9

Pill processing mi.ml.001.0901.en MediCrusher WIEGAND Article No. 98T.1 MediSplitter WIEGAND Article No. 96T PC: Polycarbonate (Makrolon) is food suitable (21 CFR 177.1580) The material is certified in USA in accordance with FDA, NSF, USDA and CPSC.CPSC. Temperature tolerance Environment / Deflection by 60 C, melting point by 280 C recyclable 07 O Cleaning directives Chemicals commercial disinfectants are unproblematic, no aggressive cleaner as acetone etc. Dishwasher at 55 C (Eco programme) without hesitation Sterilisation unsuitable 10