Design Guidelines and Development Standards for Southwood Ranch. Prepared February, 2016 by

Similar documents
Division 9 Southwood Ranch (CR 484/475/475A Corridor-Gateway Development Overlay) Purpose and Intent Applicability.

B L A C K D I A M O N D D E S I G N G U I D E L I N E S for Multi-family Development

Building and Site Design Standards

Commercial Development Permit Area

B. Blocks, Buildings and Street Networks

APPENDIX A BIG BOX RETAIL DESIGN STANDARDS

CHAPTER FIVE COMMUNITY DESIGN

LITTLETON CENTER DESIGN GUIDELINES

This chapter contains the design standards and guidelines for development and improvement of office and industrial buildings and

Site Planning. 1.0 Site Context. 2.0 Pedestrian Circulation Systems. Pag e 2-23

VILLAGE OF SKOKIE Design Guidelines for Mixed-Use Districts NX Neighborhood Mixed-Use TX Transit Mixed-Use CX Core Mixed-Use

4.0 Design Guidelines For The Village Centre. South fields Community Architectural Design Guidelines Town of Caledon

ARTICLE 8 DESIGN STANDARDS

13. New Construction. Context & Character

Appendix A COMMUNITY IMPROVEMENT PLAN DESIGN GUIDELINES

Design Guidelines for Multi-Family Residential Development

Industrial Development Permit Area

SECTION TWO: Overall Design Guidelines

Bayshore Boulevard Home Improvement District Design Guidelines

Multi family Residential Development Permit Area

ARTICLE 27 CORRIDOR OVERLAY DISTRICTS

Cha p t e r 2: Ge n e r a l De s i g n Gu i d e l i n e s

SECTION 24 DESIGN GUIDELINES FOR LARGE COMMERCIAL AND RETAIL DEVELOPMENTS INTRODUCTION & PROCEDURE 24-2

WATERFRONT DISTRICT DESIGN STANDARDS

Resolution : Exhibit A. Downtown District Design Guidelines March 2003

FREEWAY/TOURIST DISTRICT

City of Aurora Planning Department DESIGN STANDARDS FOR MOTOR VEHICLE FUEL DISPENSING STATION. August 3, 1998

lot flankage Y street 16m 6m landscape strip for large site 3m landscape strip for small medium site

MULTIFAMILY RESIDENTIAL DESIGN PRINCIPLES Site Plan and Design Review Principles Checklist

WINDSOR GLEN DESIGN GUIDELINES

ELK GROVE TOWN CENTER DESIGN GUIDELINES

5.7 Design Criteria for the Private Realm Organization of Private Realm Design Standards and Guidelines Guidelines vs.

Historic Pheasant Branch Crossing Design Guidelines

PROPOSED WATERFRONT DISTRICT DESIGN STANDARDS

Chapter 5: Mixed Use Neighborhood Character District

4. INDUSTRIAL 53 CASTLE ROCK DESIGN

Walnut Creek Transit Village Design Guidelines. Part Three III - 25

DRAFT Northeast Quadrant of Kipling Avenue and Highway 7 DRAFT AUGUST 29, Goals Land Use. The goals of this Plan are to:

Prepared by: LCT Design Group, LLC 401 North Franklin Street, Suite 5S Chicago, Illinois 60610

ZONING. 300 Attachment 1. City of Oneonta. Design Guidelines ( )

Chapter 11. Industrial Design Guidelines 11.1 INTRODUCTION AND PURPOSE 11.3 SITE PLANNING GUIDELINES 11.2 GENERAL DESIGN OBJECTIVES

VILLAGE OF CHANNAHON COMMERCIAL DESIGN GUIDELINES. Village of Channahon S. Navajo Drive Channahon, IL (815)

Chapter 4: Jordan Road Character District

1. General Purpose. 3. Uses

built form design guidelines

section five BEAUTIFICATION PLAN

Future Five. Design/ Development Guidelines. January 2008 Amended June 08 per City Council motion

Buildings may be set back to create small plazas provided that these setbacks do not substantially disrupt the street wall s continuity.

COMMERCIAL DESIGN STANDARDS

ATTACHMENT A. SILVERDALE DESIGN STANDARDS Amendments to the Waaga Way Town Center Chapter

Route 347. New York State Department of Transportation Region 10, Long Island. THE GREENING of ROUTE 347

(DC1) Direct Development Control Provision DC1 Area 4

14.0 BUILT FORM DESIGN CRITERIA

PUBLIC RIGHT-OF-WAY IN THIS CHAPTER PUBLIC REALM

Corridor Identity. Section 9. Introduction. Corridor Guiding Principles

CHAPTER 3 DOWNTOWN COMMERCIAL DISTRICT CHARACTER AREA

Town of White Springs Design Standards

D. Landscape Design. 1. Coverage Intent: To provide adequate landscaping materials that enhance the appearance of development projects.

Cit of Kitchener Ur 6 an Design Manual PARTA. Desi n for _--::

U.S. Highway 377 North Overlay District. 1. General Purpose and Description

1. Context for Design

TOWN CENTER DESIGN STANDARDS FOR THE CITY OF. August, MOUNTLAKE TERRACE TOWN CENTER DESIGN STANDARDS August,

Form & Character Development Permit Areas

CENTERS AND CORRIDORS

BOULEVARD AND PARKWAY STANDARDS

INSTITUTIONAL USE DESIGN COMPATIBILITY TECHNIQUES

EXHIBIT A. Chapter 2.7 SPECIAL PLANNED DISTRICTS. Article XVIII 15th Street School Master Planned Development

Chapter 3: Office & Office Mixed-Use Project Types

Residential Design Guidelines

Proposed for Vic West Neighbourhood Plan. Design Guidelines for Intensive Residential Development - Townhouse and Attached Dwelling

4.9 Mendocino Avenue Corridor Plan Design Guidelines

GUIDING PRINCIPLES IN THIS CHAPTER

SMALL LOT DESIGN STANDARDS. An Illustrated Working Draft for Test Implementation

Urban Design Guidelines Townhouse and Apartment Built Form

East Bayshore Road Neighbourhood

The open space system should provide connective elements, relate to natural resources, and enhance the suburban character of the landscape..

18. Form & Character Development Permit Areas

Planning Board Briefing

VEHICULAR AND PEDESTRIAN CIRCULATION

Design Guidelines for Residential Subdivisions

DESIGN GUIDELINES FOR: INTENSIVE RESIDENTIAL DEVELOPMENT TOWNHOUSE AND ROWHOUSE

CHAPTER 3. Design Standards for Business, Commercial, Industrial, Recreational and Institutional Uses

Greater East Wenatchee Urban Growth Area. Design Standards & Guidelines

WEST PICO BOULEVARD Community Design Overlay District

URBAN DESIGN BRIEF URBAN DESIGN BRIEF 721 FRANKLIN BLVD, CAMBRIDGE August 2018

VILLAGE OF HUNTLEY COMMERCIAL DESIGN GUIDELINES

Community Design Plan

Community Design Guidelines. Port Wallace DRAFT

AIRPORT BUSINESS PARK

Section 511: 11 th Street Overlay District 1. Intent: 11 th Street is the primary entrance route into the city from the south, providing direct

SECTION V: DESIGN GUIDELINE EXAMPLES

ARTICLE XIII USE PROVISIONS. Section Mall of Georgia Overlay District Requirements:

appendix and street interface guidelines

Urban Design Brief December 23, 2015 Southside Construction Group Official Plan & Zoning By-Law Amendment

Standards (R-3) Figure B-11: R-3 Residential Standards Exhibit

Othello Neighborhood Design Guidelines

Highland Village Green Design Guidelines

Urban Design Brief. 875 Wellington Road. Proposed One-Storey Fast Food Restaurant and Two-Storey Restaurant. Wellington Harlech Centre Inc.

CITY OF MADISON, WISCONSIN

Village of Carpentersville Development Standards & Design Guidelines. prepared by Houseal Lavigne Associates

Transcription:

Design Guidelines and Development Standards for Southwood Ranch D e s i g n D i s t r i c t Prepared February, 2016 by

Table of Contents Introduction 2 District Overlay Map. 3 Development Standards. 4 Architecture Standards 5-7 Entry Feature / Wayfinding.. 8 Public Streetscape... 9-10 Storm water Treatment.. 11 1

INTRODUCTION The Southwood Ranch Design District is intended to be a mixed use community that creates an attractive, efficient, and safe development pattern in a defined portion of southern Marion County that will support the equine industry including the Florida Horse Park. The district abuts the Cross Florida Greenway, which will allow opportunity for more visitors to access this unique linear park that has become an eco-tourism destination. The district will include both commercial and residential uses which will allow the community to be continuously activated with users of all demographics. The design district will define architectural styles, setbacks, public streetscape features, landscape buffers, and access locations. This district will apply to any new development, redevelopment, or expansion of existing development, including residential and nonresidential projects. Marion County Location Map 2

DISTRICT OVERLAY MAP 3

DEVELOPMENT STANDARDS 1. The streets and the roadway network shall promote pedestrian activity in a safe and comfortable environment. 2. Utilities shall be located/buried such that tree installations are possible. 3. Site lighting along driveways shall be consistent in type and color, with those used in the common areas and should generally not exceed 35 feet in height; pedestrian level lighting should generally not exceed 16 feet in height. 4. A detailed signage and wayfinding plan for each Parcel showing proposed sign locations shall be included with the final site plan application in each Parcel. 5. Open space shall meet the Marion County Land Development Code requirements. This shall be illustrated on an individual parcel basis and demonstrated with each Major Site Plan submittal. 6. Sidewalks shall be provided on one (1) side of the internal road network. 7. Parallel access shall be established in a manner that provides a functional internal road network and does not rely on numerous ingress / egress locations on major roadways. 8. Access to CR 475 and CR 475A will be limited to specific locations that correspond with greater access for the region. GATEWAY FEATURE LOCATION 4

ARCHITECTURAL STANDARDS 1. The project architecture shall promote and enhance a pedestrian scale and orientation on any façade, especially those facing a public right-of-way through building articulation, transparency, or other design treatments. 2. Exposed Building façade shall consist of durable material such as stone, stucco, brick, hardi board, split face block, etc. 3. Provide articulated facades with offsets and recessed entries. No blank walls shall be visible from the public right-of-way. 4. Any rooftop equipment shall be screened from the public right-of-way 5. Avoid long, monotonous building facades. 6. Every elevation shall be broken up through the use of decorative architectural features such as change in plane; molding; columns, cornice, frieze or arches; rigid awnings or canopy; color and texture variations; recessed windows or doors, bay windows, window sills, window boxes or false windows, decks and covered patios; exposed structural elements like steel or timber beams. 7. Roofs shall be gable, gambrel, hipped, or otherwise broken up through varying planes. Flat roofs with varying planes shall be considered on a case-by-case basis when appropriate to the architectural character of the building. The height of roof lines for large buildings shall be varied through the use of parapets or other architectural elements to reduce the building scale. 8. Service and loading areas shall not be placed on the front or street side of a building, but rather at the rear or side of the building. 5

ARCHITECTURAL STANDARD Primary entrances to buildings should be distinguished with façade variations, porticos, roof variations, recesses or projections, or other integral building forms. 1. Building colors should emphasize muted earth tones. The use of highly reflective or glossy materials should be limited and are not appropriate in all contexts. 2. All sides of a building should express consistent architectural detail and character. All site walls and screen walls should be architecturally integrated with the building or as approved as part of an overall master plan area. 3. Screening devices, site walls and enclosed service, loading and refuse areas should be designed to be an integral part of the building architecture. 6

MATERIALS Rich materials and a variety of materials are desirable on both the wall planes, roofs and ground plane. If stone or decorative block veneers are incorporated, the material should be used to highlight significant building features and massed elements. 7

ENTRY FEATURE / WAYFINDING 1. Entry features and monument signage shall be strategically located at major intersections and thresholds into the design district to provide a sense of arrival and way finding from public right-of-ways. 2. Signs visible from CR 475 and CR 475A shall be monument signs only and shall not exceed one square foot of sign area per foot of frontage up to a maximum of 100 square feet. These signs shall not exceed 10 feet in height. 3. Wayfinding signs shall be permitted on internal roadways to the development and shall not exceed 24 square feet per sign face. These signs shall not exceed 6 feet in height. MONUMENT SIGN ELEVATION GATEWAY FEATURE 8

PUBLIC STREETSCAPE 1. The buffers along the CR 475 and CR 475A right-of-way shall be designed to enhance the view shed from the roadway and provide a unique sense of place. 2. A 45 feet wide multi-use easement shall be provided outside of the rightof-way. This easement shall contain 3- board wood fence segments strategically located, landscape plantings on a 2 3 feet tall berm, and an undulating multi-modal trail that is 10 feet wide. 3. An equestrian trail network shall be established to connect the Florida Horse Park and the Cross Florida Greenway equestrian trails to commercial and residential areas. 4. The development that is adjacent to the multi-use easement shall provide a 15 feet landscape buffer. 5. The buffer shall contain 2 canopy trees and 3 understory trees per 100 lineal feet. 50% of the buffer shall contain plantings other than sod. (Marion Friendly and Florida Native Plants only) 6. No parking or drive aisle shall be provided between the building and the landscape buffer. PUBLIC STREETSCAPE PLAN VIEW 9

PUBLIC STREETSCAPE 10

STORMWATER TREATMENT 1. Storm water runoff treatment / retention areas shall be designed to be functional areas for the treatment of surface runoff contaminants, as well as aesthetic features that enhance the development. 2. Storm water treatment areas can be designed and built at various scales. 3. Uses for the retention areas other than storm water treatment / retention include traffic calming, rain gardens, passive parks, visual amenities, etc. 11