Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch

Similar documents
Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

Drawing Submittal Package

Drawing Submittal Package

Technical Data Submittal Document

LMR Electric Fire Pump Controllers Features

Technical Data Submittal Documents

LMR Electric Fire Pump Controllers Features

FDF Foam Pump Controllers Features

Model GPS + GPU Full Service Reduced Voltage Soft Start Soft Stop Electric Fire Pump Controller with Automatic Power Transfer Switch

Model GPS + GPU Full Service Reduced Voltage Soft Start Soft Stop Electric Fire Pump Controller with Automatic Power Transfer Switch

Model GPP Full Service Reduced Voltage Part Winding Electric Fire Pump Controller

Model GPW + GPU Full Service Reduced Voltage Wye-delta Closed Electric Fire Pump Controller with Automatic Power Transfer Switch

Model GPY + GPU Full Service Reduced Voltage Wye-delta Open Electric Fire Pump Controller with Automatic Power Transfer Switch

FT60 Reduced Voltage - Autotransformer

Model GPS Full Service Reduced Voltage Soft Start Soft Stop Electric Fire Pump Controller

Model GPA Full Service Full Voltage Across the Line Start Electric Fire Pump Controller

Transfer Switch Features

Model GPW Full Service Reduced Voltage Wye-delta Closed Electric Fire Pump Controller

Transfer Switch Features

FT40 Reduced Voltage - Part Winding. Electrically and Mechanically

Soft Start Series MP700 Solid State, Reduced Voltage

FD30 Full Voltage - Across the Line July 2011

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

Across-the-Line SERIES MP300 Combined Manual and Automatic

FT20 Full Voltage - Limited Service. Electrically and Mechanically

Fire Pump Controllers Medium Voltage Controllers

Customer Connection Terminals Connection terminals for external customer connections, are located at the top of the Power I/O board.

Variable Frequency Drive SERIES MP800 VFD

DIESEL Engine Fire Pump Controllers Features. FD120 Diesel Engine Controllers

DIESEL Engine Fire Pump Controllers Features

WITH POWER TRANSFER SWITCH STANDARD SUBMITTAL PACKAGE

Fire Pump Controllers Foam (Additive) Controllers

FDJ SERIES Jockey Pump Controllers Features

Technical Data Submittal Documents

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

SECTION Fire Pumps

Options for Diesel Fire Pump Controllers

VACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES

DIESEL Engine Fire Pump Controllers Features

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION FIRE PUMPS 1.00 PART 1 & GENERAL Description of Work. A. Provide pumps for fire suppression Section Includes

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

CONTENTS AUTOMATIC TRANSFER SWITCHES

Fire Pump Controller. For Electric Motor Driven Fire Pumps. Wye Delta Reduced Current Types

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

PUMP CONTROL CENTER (PCC)

SECTION AUTOMATIC TRANSFER SWITCHES

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Guide Specification Model CTG Automatic Transfer Switch

MANUAL FOR MODEL MP600 HIGH VOLTAGE ELECTRIC MOTOR DRIVEN FIRE PUMP CONTROLLERS

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

FTA550 JOCKEY PUMP CONTROLLERS

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

Microprocessor Based Wye-Delta Reduced Current Type Starting

P.C. Simonton & Associates, Inc. Consulting Engineers. Paul C. Simonton

EATON LMR Plus Electric Fire Pump Controllers

A. This Section includes transfer switches rated 600 V and less, including the following:

PILOT SERIES MPT700TS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Remote Alarm Panels Features

SECTION 4000 LIFT STATIONS

Commercial and Light Industrial Fire Alarm Control Panel

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

FTA550F JOCKEY PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

Table of Contents. Protective Relays

UC700 EMERGENCY TRANSFER SYSTEM SPECIFIER S HANDBOOK. 40 Dale Street West Babylon, NY Ph: Fx:

Moulded case circuit brakers

Model GPD Diesel Engine Driven Fire Pump Controller

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018

Specification/ Data Sheet

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

TS Series. Technical Instructions. Document No. TS-4000 June 25, TS-CE Combustion Enclosures with LMV5. Description

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES. READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION.

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

SCC Inc. TS Series. Technical Instructions. Document No. TS 1000 June 25, TS Touchscreen Kits. Description. Touchscreen

Packaged Instantaneous Circulation Heater Full KW Selection In All Voltages, Single or Three Phase

University of Houston Master Construction Specifications Insert Project Name SECTION FIRE PROTECTION PUMPS PART 1 - GENERAL

Model APD. Remote alarm panel for diesel motor driven fire pump. Drawing Submittal Package

Centro-Matic Automated Lubrication Systems System Controls

SCC Inc. TS Series. Technical Instructions. Document No. TS 5000 February 12, TS CE Combustion Enclosures with LMV3.

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY

FTA200-A REMOTE ALARM PANEL

Conventional Releasing Control Panel

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

R E C T I F I E R I N V E R T E R C O N V E R T E R SB7

Heating Cable. Description

ASCO Series 185 Power Transfer Switches

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

Two-Channel Gas Controller

7800 SERIES RM7840E,G,L,M; EC7840L Relay Module

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

SECTION ROTARY-SCREW WATER CHILLERS

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

Transcription:

Project: Customer: Engineer: Pump Manufacturer: Technical Data Submittal Document Model VPS + VPU Pressure Limiting (VFD) with Soft Start Bypass with Automatic Transfer Switch Contents: Data Sheets Dimensional Data Wiring Schematics Field Connections Note: The drawings included in this package are for controllers covered under our standard offering. Actual AS BUILT drawings may differ from what is shown in this package.

with Automatic Transfer Switch From Transfer Switch* 1R CR6 CR8 CR7 1R 4R 4R CR6 CR7 CR8 2R 3R FU1 SSS1 2R 3R LR1 VFD1 POWER MODULE Standard, Listings and Certifications Built to NFPA 20 Underwriters Laboratory (UL) New York City UL218 - Fire Pump Controllers UL 1008 - Automatic power transfer switches for fire pump controllers Accepted for use in the City of New York by the Department of Buildings Enclosure Protection Rating Standard: NEMA 2 (IP31) Optional NEMA 12 NEMA 3 NEMA 3R IP54 Accessories Bottom entry gland plate Lifting lugs Keylock handle Paint Specifications Red RAL3002 Powder coating Glossy textured finish Shortcircuit Withstand Rating 200V to 208V 60Hz 220V to 240V 60Hz 380V to 416V 50 Hz / 60Hz 440V to 480V 60Hz 600V 60Hz HP Standard 100kA Optional 150kA Standard 50kA Optional 100kA 5-60 5-60 5-300 5-400 n/a n/a n/a n/a n/a 5-500 *Please see Disconnecting Means details on page 3. 2

with Automatic Transfer Switch Ambient Temperature Rating Operating Modes Surge Suppression Disconnecting Means Service Entrance Rating Standard: 5 C to 40 C / 41 F to 104 F The controller shall have the capability of running the pump motor in the following three (3) modes via a speed mode selector switch: Variable mode: Upon an automatic or manual start, the controller shall start the pump through the variable frequency drive (VFD) and instantly regulate the motor speed in reference to the discharge pressure Preset mode: Upon an automatic or manual start, the controller shall start the pump through the variable frequency drive (VFD) and run the pump motor at a pre-determined speed. This pre-determined speed shall be adjustable on the variable frequency drive (VFD) itself Bypass mode: Upon an automatic or manual start, the controller shall start the pump through the reduced voltage soft start bypass circuit. Surge arrestor rated to suppress surges above line voltage Isolating switch and circuit breaker assembly: - Door interlocked in the ON position - Isolating switch rated not less than 115% of motor full load current - Circuit breaker continuous rating not less than 115% of motor full load current - Overcurrent sensing non-thermal type, magnetic only - Instantaneous trip setting of not more than 20 times the motor full load current Common flange mounted operating handle Suitable as service entrance equipment Emergency Start Handle Flange mounted Pull and latch activation Integrated limit switch Across the line start (direct on line) Locked Rotor Protector Operate shunt trip to open circuit breaker Factory set at 600% of motor full load current Trip between 8 and 20 seconds Electrical Readings Pressure Readings Pressure and Event recorder Pressure Sensing Voltage phase to phase (normal power) Amperage of each phase when motor is running Continuous system pressure display Cut-in and Cut-out pressure settings Pressure readings with date stamp Event recording with date stamp The recorder will register and keep in memory pressure fluctuations over time that have occurred over the previous seven (7) days and events, alarms, general system information that have occurred over the previous fifteen (15) Information is retrievable through DB9 communication port accessible without having to open the controller door. Pressure transducers (2) for reading of discharge pressure Pressure sensing line connection (1/2 Female NPT) Rated for 0-600PSI working pressure Externally mounted with protective cover 3

Audible Alarm Visual Indications Alarm buzzer power available power available position position Technical Data with Automatic Transfer Switch Individual phase-to-phase voltage indication + Hz frequency (normal power) Individual phase current indication Pressure indication Elapsed run time Visual & Audible Alarms Visual only loss Motor run Phase reversal Phase unbalance Visual and Audible Overcurrent Undercurrent Fail to start Audible only Fault SSS (soft-start) Phase loss L1 Phase loss L2 Phase loss L3 Low System pressure Pressure transducer problem By-pass mode VFD Failure Undervoltage Overvoltage Locked rotor System trouble Remote Alarm Contacts DPDT-8A-250V.AC available Phase loss loss Overvoltage Undervoltage Phase unbalance Common motor trouble Overcurrent Undercurrent Fail to start Pressure transducer problem Phase reversal Bypass mode VFD Failure Motor run ***Can only be used if approved by the AHJ 4

Operator Interface Operation Technical Data with Automatic Transfer Switch Micro-processor based Accessible without opening main door Voltage and current indication Pressure settings and system pressure indication 15 day pressure and 15 day event Automatic Start Manual Start Stopping Timers Actuation Mode Start on pressure drop Start pushbutton Remote start from manual device Manual with Stop pushbutton Automatic after expiration of minimum run timer *** Field Adjustable & Visual Countdown Visual Indication Minimum run timer ***(off delay) Sequential start timer (on delay) Periodic test timer Pressure Automatic Non-automatic 5

with Automatic Transfer Switch Automatic Transfer Switch Surge Suppression Disconnecting Means Locked Rotor Protector Visual Indications Visual and Audible Alarms Surge arrestor rated to suppress surges above line voltage Isolating switch and circuit breaker assembly: - Door interlocked in the ON position - Isolating switch rated not less than 115% of motor full load current - Circuit breaker continuous rating not less than 115% of motor full load current - Overcurrent sensing non-thermal type, magnetic only - Instantaneous trip setting of not more than 20 times the motor full load current Common flange mounted operating handle Operate shunt trip to open circuit breaker Factory set at 600% of motor full load current Trip between 8 and 20 seconds (emergency) isolating switch in the OFF position (emergency) voltage phase to phase + frequency Transfer switch in normal or alternate position Isolating switch in OFF position Electrically operated and mechanically held in the normal or alternate position Provision for manual operation Remote Alarm Contacts SPDT-8A-250VAC Isolating switch in the OFF position Transfer switch in normal position Transfer switch in alternate (emergency) position Time Delays Momentary normal power outage override (factory set at 4 sec) (emergency) power available delay (factory set at 1 sec) Retransfer to normal (factory set at 5 min) Generator cooldown (factory set at 5 min) Voltage Sensing Transfer to alternate (normal power dropout) 85% of nominal Phase reversal transfer to alternate Retransfer to normal (normal power pickup) 90% of nominal Audible Alarm (AIS Open) Alarm buzzer Generator Start Connection SPDT-8A-250V.AC 6

with Automatic Transfer Switch A06B A07B A9 A10 A11 B11 B11B B19A B19B C1 C4 C7 C10 C14 C15 C18 C19 C21 C22 C23 C24 Cx Lockout Circuit from other VPx Interlock Circuit from other VPx Low zone pump control function Medium zone pump control function High zone pump control function Built in alarm panel (120V.AC supervisory power) providing indication for: Audible alarm & silence pushbutton for motor run, phase reversal, loss of phase. Pilot lights for loss of phase & supervisory power available Built in alarm panel same as B11 but 220-240VAC supervisory power High motor temperature c/w thermoster relay and alarm contacts (DPDT) High motor temperature c/w PT100 relay and alarm contacts (DPDT) Extra motor run alarm contact (DPDT) Periodic test alarm contact (DPDT) Low pump room temperature alarm contact (DPDT) Low water reservoir level alarm contact (DPDT) Pump on demand / automatic start alarm contact (DPDT) Pump fail to start alarm contact (DPDT) High water reservoir level c/w visual indication and alarm contact (DPDT) Emergency start alarm contact (DPDT) Deluge valve start alarm contact (DPDT) Remote automatic start alarm contact (DPDT) Remote manual start alarm contact (DPDT) High pump room temperature alarm contact (DPDT) Additional visual and alarm contact (Specify function) (DPDT) Note: Options chosen from this page are not electrically represented on the wiring schematics in this submittal package. D1 D1A D13 D14 D14A D14B D15 D24 D26 D26A D27 D27A D28 D37 E1 E2 E3 F2 F2A F2B F6 F10 Low suction pressure transducer for fresh water rated at 0-300PSI with visual indication and alarm contact Low suction pressure transducer for sea water rated at 0-300PSI with visual indication and alarm contact High withstand rating for (normal power section) 208V to 480V = 150kA 600V = 100kA Anti-condensation heater & thermostat Anti-condensation heater & humidistat Anti-condensation heater & thermostat & humidistat Tropicalization Audible Alarm Modbus with RTU frame format and RS485 connection Modbus TCP / IP provision Motor heater connection (external single phase power source and heater on/off contact) Motor heater connection (internal single phase power source and heater on/off contact) Customized drawing set Window kit for operator interface Permanent load shedding contacts Temporary pump motor start period load shedding contacts Temporary & permanent load shedding contacts Anti condensation heater & thermostat (alternate power section) Anti condensation heater & humidistat (alternate power section) Anti condensation heater & thermostat & humidistat (alternate power section) High withstand rating for (model GPU only) : 208V to 480V=150kA 600V=100kA IP55 assembly 7

with Automatic Transfer Switch L01 L02 L03 Other language and English (bilingual) French Spanish Additional Options: Note: Options chosen from this page are not electrically represented on the wiring schematics in this submittal package. 8

Operator Interface Technical Data with Automatic Transfer Switch Current / Time Pressure L1-L2 L2-L3 L3-L1 V. / Hz V. / Hz A. / Hr Available Position Phase Reversal Low System Pressure Altern. Available Position Isolating Switch in Off Position System Trouble Cut-out Cut-in Reset Test Print Paper Feed Trouble Legend : P : Pump Starting Failure O : Overcurrent Problem U : Undercurrent Problem T : Pressure Transducer Problem 9