EXTINGUISHES FIRES QUICKLY AND EFFECTIVELY. FirExting Gas extinguishing systems with non-liquefied and natural inert gases. Nitrogen Argon IG-541

Similar documents
Fire protection for a hazardous materials. warehouse. OxyReduct FirExting TITANUS. Reference solution

FIRE PROTECTION IN SUB-ZERO TEMPERATURES. DELIVERY CAPACITY ON ICE. DELIVERY CAPACITY WITH GUARANTEED PROTECTION.

Fire protection in high-bay warehouses:

Active fire prevention OxyReduct

OxyReduct TITANUS. Reference solution Fire prevention and early fire detection in a cold storage

ORGANISE YOUR SAFETY. VisuLAN X3 Integral safety and property management system. Risk management Product information

POCKET-SIZE / HIGH PERFORMANCE POWER DEVICES REQUIRE ADVANCED FIRE PROTECTION SOLUTIONS.

Saving lives, protecting valuables, securing process cycles Fire detection

Saving lives, protecting valuables, securing process cycles Fire detection

Oxeo extinguishing systems

GAS EXTINGUISHING SYSTEMS INERT GAS. Argotec with argon or nitrogen

CO 2 EXTINGUISHING SYSTEMS

GAS EXTINGUISHING SYSTEM INERT GAS. Argotec with carbon dioxide. Safe for certain.

Sinorix Silent Extinguishing Technology protecting the quiet way

What extinguishes fires without pressure peaks?

Carbon Dioxide Extinguishing Systems Fighting fire with CO2

Aspirating Smoke Detection (ASD) Systems Fire Detection

Technologies Gas extinguishing systems. MX 1230 Fire Extinguishing Systems Fighting Fire using 3M Novec 1230

Technologies Gas extinguishing systems. MX 200 Fire Extinguishing Systems Fighting Fire using HFC-227ea

Effective, efficient response for emergency situations Risk Management

Branch Solution Wood based panel plants. Fire protection solutions for wood based panel plants

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

Fire suppression systems for server rooms and data centres

Element C3.4 Fire Fighting Equipment

KD Innovative extinguishing with Novec TM 1230 by 3M TM

Safe, Effective, Environment-friendly

Fire protection for emergency power supply

GAS EXTINGUISHING SYSTEMS INERT GAS. Argon Extinguishing Systems. Fire Protection Systems

AUTOMATIC FIRE SUPPRESSION SYSTEMS

ODS & SGG Alternatives for the Fire Protection Industry 2018

Water mist fire suppression systems. Minifog ProCon Low-pressure water mist system

How can you minimize consequential damages in case of a fire?

Protecting Critical Facilities Against Explosions

ON-TRACK FOR TAILORED FIRE PROTECTION. Future-proof fire protection solutions for rail vehicles

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009

Technologies Fire Prevention Systems. Oxeo Prevent Oxygen Reduction System Active Fire Prevention using natural Nitrogen

PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems

Vaults 5/03/2015. Introduction. Vault Types. Stand alone building Free standing structure VAULTS

FIRE SUPPRESSION SYSTEM

Fire protection solutions for ships and offshore facilities BRANCH SOLUTION

Welcome to Argonite fire protection from Ginge-Kerr

w-fog RG-SYSTEMS W-FOG WATER MIST CO-OPERATI

Protezione antincendio di dati e business critical assets nei Data Centers

Water Mist Fire Suppression

Press Presse Press Presse

FIRE PROTECTION TECHNOLOGY Solutions never thought of before

Protecting Facilities Against Explosions. Since 1956

Fire Prevention Systems

I wish I could protect my business with the most suitable Water Mist solution to fit my needs.

Highly Protected Risks in Power Generation Stewart Kidd outlines the issues to consider when installing active fire suppression in power stations THE

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle.

Fireward Fixed Fire Fighting System. For Open Areas & Enclosed Risks fireward.co.uk

CO 2 Fire Extinguishing Systems

XC10 combined fire detection and extinguishing control

Fire Suppression Systems

XC10 combined fire detection and extinguishing control

The Combustion Process THE FIRE TETRAHEDRON FUEL TEMPERATURE

International Safety Guide Chapter 30 for Inland Navigation Tank-barges and Terminals. Chapter 30 FIRE-FIGHTING

VdS Guidelines CONTENTS

BOC FS125 The Fire Extinguishing Solution

FIRE AND FIRE FITTING By Mr. Prashant Sansare

Fire Protection for Catering Kitchens KS 2000 Compact Extinguishing System. Safe for certain.

(Material correct at 1/11/2011)

CO 2. fire extinguishing systems

SPECIAL HAZARDS THE MOST ADVANCED TECHNOLOGY FOR PROTECTING

Economic batch production

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust

Solutions. Fire risk under control in welding fume extraction systems

Risk Management Department. Fire Extinguishers

What is HI-FOG? The natural enemy of fire

Fire Suppression. Water-Mist : A Revolutionary Green Technology in. - by Nimit Sheth TALL, SMART, SAFE BUILDINGS FOR SMART CITIES.

Dräger Pac 6000 Single-Gas Detector

RISK ENGINEERING GUIDELINE.

For more information on Tarkett go to

STANDARDS FOR ACTIVE FIRE PROTECTION. Stewart Kidd Loss Prevention Consultancy Ltd

Institute for Plasma Research Welcomes you all on

...extinguish it with a water spray.

Fire protection for buildings

AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS

GX-20/FM-200 Fire Extinguishing System

IMO. Resolution A.951(23) Adopted on 5 December 2003 (Agenda item 17) IMPROVED GUIDELINES FOR MARINE PORTABLE FIRE EXTINGUISHERS

S12 Fire Safety Risk Assessment H&SFS01-1 / 9

Fire Protection for Catering Kitchens KS 2000 Compact Extinguishing System. Safe for certain.

Fire Safety. Presenter, Kevin V Coleman September 14 th 2016

Hazardous Goods Warehouse. VOSSCHEMIE GmbH. Preventive Fire Protection. Case study

Directories. B.1 Keyword Directory B.2 Tables B.3 Figures B.4 End Notes Fire Safety Guide / Siemens Switzerland Ltd

Fire Extinguisher Training

Aerosol Fire Suppression. Your Choice for Special Hazard Fire Protection

Essentials of Fire Fighting 6 th Edition Firefighter I

Minifog EconAqua Water mist sprinkler systems

Fire fighting Questions

How can I protect invaluable assets and the environment from the effects of a fire?

Cadet Entry Level Award(ELA) Part Four. Fire Safety

Fire Extinguisher Training

INSTRUCTOR GUIDE COURSE: FIREFIGHTER PRE-BASIC SESSION REFERENCE: 1 TOPIC: ORIENTATION AND FIRE BEHAVIOR LEVEL OF INSTRUCTION:

INDEPENDENT FIRE EXTINGUISHER SALES & SERVICES. Your First Line of Defense Since 1971

STEPHAN VACUTHERM SYSTEM Economic batch production

Minifog PressProtect Fire protection solutions for industrial presses BRANCH SOLUTION

Water mist fire suppression systems. Minifog EconAqua Water mist sprinkler systems

automatic FiReFighTing SYSTeMS in PainT booths

Transcription:

Fire extinguishing Product information EXTINGUISHES FIRES QUICKLY AND EFFECTIVELY FirExting Gas extinguishing systems with non-liquefied and natural inert gases Nitrogen Argon IG-541

MINIMISE FIRE DAMAGE WITH NON-DESTRUCTIVE INERT GAS EXTINGUISHING Inert gas extinguishing systems from WAGNER make a crucial contribution in comprehensively protecting existential assets from fire damage Effective technical protection from fire and its consequences is based on multiple interacting measures. It is based on a fire detection which must ensure reliable, earliest possible detection. Once a fire has been detected, suitable countermeasures must be taken as quickly as possible. After all, the shorter the timeframe between when the fire is detected and the extinguishing commences, the more effective the fire and consequential damages can be prevented. Fight fire without damage Aside from personal safety, protecting valuables and operational procedures take top priority during the extinguishing process. The extinguishing process must be ideally coordinated to the field of use and may not cause any damage itself. For that reason, WAGNER exclusively uses gas extinguishing for fighting fires with FirExting. Suitable extinguishing gases can quickly and reliably stop combustion processes without causing damage and leaving residue on buildings, equipment and goods. 2

FirExting extinguishing with natural inert gases Fire extinguishing without residue Prevents consequential damage to equipment Protects from operational or process failures Individual solutions with inert gas extinguishing systems A fire extinguishing installation with inert gases is especially recommendable for areas with demanding protection requirements. This is the case if there are irreplaceable cultural goods or sensitive technology to protect, if maximum availability is required, or if there are special risks in the protected area on account of high fire loads, electrical energy or hazardous substances. Thousands of FirExting gas extinguishing systems are already in use worldwide today. Nitrogen is used in more than 80 % of inert gas extinguishing systems installed by WAGNER due to its favourable universal properties. In the case of fire loads near the fire or certain metal fires, argon can also be used on account of its very high density and inertness. The extinguishing gas mixture IG- 541 (consisting of N 2, Ar, CO 2 ) can also be used as an alternative. Typical areas of use FirExting systems protect rooms and buildings from small server cabinets to large warehouses: Server rooms, IT/EDP areas and data processing centres Building systems/control cabinets Telecommunication equipment Museums, archive rooms, depots High-bay warehouses Automatic storage systems Hazardous substance and flammable liquid storage Lacquering and powder coating systems Printing machines Tool machines Fire Insesity (logarithmic representation) Course of fire and intervention Invisible Combustion Phase Fire Detection FirExting Life Threatening Smoke Build up Phase Smoke Extinguishing An automatic gas extinguishing systems earliest fire detection and quick intervention effectively prevent fires from spreading and the fires it causes. Heat Flames Flashover Fire Brigade Time 3

EFFECTIVELY STOP THE FIRE WITH NATURAL INERT GASES Inert gases use a simple extinguishing principle: They suffocate the source of the fire by displacing the oxygen from the environment. Fires can only break out if all three components of the fire triangle (oxygen, heat energy and fuel) are present. Feeding in ignition energy in the form of heat initiates a combustion reaction and causes the fuel and oxygen to begin reacting to one another. Once the reaction has started, fuel is continuously fed in the form of oxygen, giving off heat a fire breaks out. Take the fuel from the fire When a fire is detected, the gas extinguishing system is triggered. This can take place automatically as well as manually. The area to be protected is flooded with extin guishing gas; the oxygen is displaced. This reduced the oxygen content in the protected area from the normal 20.9 vol% to a concentration set to the specific building, which stops the combustion process. After that, the concentration of extinguishing gas will have to be retained for a defined hold time (such as 10 minutes) in order to prevention reignitions. Inert gases are wellsuited to effectively extinguish class A (solid substances), B (flam mable liquids) and C (flammable gases) fires with this process. 4

Extinguishing without residue and water damage Extinguishing without sideeffects Inert gases enable residue-free extinguishing which prevents secondary damages such as those caused by the use of water, foam, powder or chemical extinguishing gases. Moreover, they do not react with any chemical compounds which occur in the usual fire scenarios. They do not conduct electricity and thus cause no short circuits during and after the extinguishing process. This makes them ideal for use in electrical and electronic systems. Inert gases spread quickly and homogenously throughout the entire room and thus dependably extinguish fire sources, even ones which are concealed. The fire triangle: Fire extinguishing through oxygen displacement Simple disposal, quick refilling The inert gases nitrogen and argon occur in the natural atmosphere, are not toxic in concentrations for extinguishing fires, and can be disposed of without special requirements. Refilling is a simple and inexpensive Oxygen Fire hazard Heat Oxygen Nitrogen Heat Fire hazard process, making the extinguishing system quickly ready for operation again. Fuel Fuel Inert gas extinguishing reduces the oxygen concentration in the protected area and stops the combustion process by suffocating it. 5

FIGHT FIRES EFFECTIVELY WITH INDIVIDUAL CONCEPTS Depending on the specific requirements, the non-liquefied inert gases nitrogen (N 2 ), argon (Ar) or IG-541 are used as extinguishing agents in FirExting systems. The extinguishing agent is supplied in pressurised cylinders and is used to flood the extinguishing zone in the event of fire. All of the inert gases for use in FirExting systems are of natural origin, non-toxic, not electrically conductive and do not cause any visual impairments when used. It is easy to maintain concentrations of these gases which are suitable for extinguishing fires in the protected area, thus effectively preventing reignitions. Nitrogen (N 2 ) Nitrogen is one of the most effective natural extinguishing gases. WAGNER is the first extinguishing technology provider to use nitrogen. Nitrogen has a similar density to air and spreads homogeneously in the room, thus taking effect very well. It is readily available and easy to obtain 78.09 vol% of the atmosphere is made up of nitrogen. Refill costs are low. Nitrogen is versatile and universal in its applications. Argon (Ar) Argon is a non-toxic noble gas which is contained in the atmos phere at up to 0.93 vol% Argon does not enter into any chemical compounds amongst the inert gases even under extreme conditions. Thanks to its inertness, it is also used to fight fires at very high temperatures. Argon s high specific weight (38% heavier than air) makes it ideal for extinguishing areas with fire loads near the floor, as well as in raised floors. Refill costs are low. IG-541 IG-541 is a mix of natural inert gases which makes use of their respective benefits. It is made of 52 vol% nitrogen, 40 vol% argon and 8 vol% carbon dioxide. Due to its composition, the refilling costs with IG-541 are a bit higher than those with nitrogen or argon. 6

Tailor-made protection concepts with FirExting FirExting can be tailored precisely to meet many different requirements: from system configuration for one or more protected areas to the right extinguishing gas. The decision as to which extinguishing gas to use is part of the specific planning process for the entire system. Configuration and functioning of a gas extinguishing system A FirExting gas extinguishing system consists of an extinguishing control panel outside of the extinguishing zone and a pipe network with extinguishing nozzles which leads into the extinguishing zone. If a fire is detected, the system will activate automatically or by manual release. First, persons receive a visual and acoustic alarm to let them know to leave the protected area. In terms of fire safety, operating media such as ventilation and air-conditioning systems must be shut down in order to prevent reignition. Doors and fire protection dampers are automatically closed. After a delay period, the protected area will be flooded with extinguishing gas within the specified period (generally 60 or 120 seconds) in order to extinguish the fire once the extinguishing gas concentration is reached. This must be maintained for at least ten minutes to prevent potential reignitions. Single and multi-zone installations The figure shows a typical singlezone installation. Several zones (incl. zones of different sizes) can be protected by a FirExting multizone installation. In this case, the extinguishing gas is transported to the protected area concerned through selector valves. A multi-zone installation is generally more costeffective than having several single-zone installations, since the quantity of extinguishing gas supplied will be lower. In the extinguishing zone In the fire extinguishing installation Manual release Enables you to manually activate the extinguishing system if a fire is detected Smoke detectors Monitor the extinguishing zone, send an alarm to the extinguishing control panel if smoke is detected Acoustic and optical alarm devices Ensure that everyone has left the protected area during the pre-warning period 3 Extinguishing cylinders Cylinders holding 80 or 140 litres of non-liquefied extinguishing gas under 300 bar pressure are supplied individually or in cylinder batteries Air sampling smoke detection system Continuously analyses the room air actively by taking samples of the air, detecting even the most minimal smoke as early as possible 1 2 4 5 6 7 8 Pressure relief Prevents an impermissible rise in pressure when the extinguishing zone is being flooded Gas extinguishing nozzles Located on the end of the pipework, these route the extinguishing gas into the extinguishing zone Fire / extinguishing control panel Processes fire detection signals, triggers alarm and floods the extinguishing zone after the specified prewarning period

Flow regulator for soft flooding PREVENT PRESSURE PEAKS WITH SOFT FLOODING When gas extinguishing is released, the room pressure in the protected area will briefly rise. WAGNER Soft Flooding offers an effective solution for spacesaving and cost-reducing pressure relief. In order to build up a suitable concentration for extinguishing with a subsequent hold time, the protected area must be sufficiently tight. In the event of fire, the pressure in the room will increase due to the flooding process. Pressure relief devices are needed for compensation purposes. FirExting systems from WAGNER are also available in a soft flooding version. The extinguishing gas cylinders are equipped with flow regulators. The protected area will be flooded with a constant and controlled pressure. The reduced pressure peaks enable smaller dimensions for the pipework and reduce the pressure release surfaces by more than 50%. This makes it easier to install gas extinguishing systems under difficult structural conditions, such as interior rooms. Extinguishing with standard flooding Extinguishing with soft flooding Mass flow (kg/s) 140 120 100 80 60 40 Mass flow Pressure gradient Pressure relief surface 100 % 70 60 50 40 30 20 Room pressure (mbar) Mass flow (kg/s) 140 120 100 80 60 40 Mass flow Pressure gradient Pressure relief surface approx. 50 % smaller 70 60 50 40 30 20 Room pressure (mbar) 20 10 20 10 0 0 0 50 100 150 200 250 300 Time [s] Sample mass flow and room pressure curve with classic inert gas flooding 0 0 0 50 100 150 200 250 300 Time [s] Sample mass flow and room pressure curve with soft flooding with inert gas 8

Optional accessories for FirExting VdS-certified sound suppressor SILENT SPECIAL PROTECTION FOR EDP SYSTEMS WITH FirExting SILENT Specially designed sound suppressors are used in IT areas to protect sensitive electronics from damage caused by vibrations. When a gas extinguishing system is triggered, the rushing noise from the nozzles can reach a sound pressure level of up to 130 db (A). This can cause hard disks and other sensitive parts to vibrate, thus damaging them. WAGNER can reduce the sound pressure level of its FirExting systems by 20-38 db (A) through the use of VdS-approved Silent sound suppressors. This makes WAGNER the first manufacturer to develop a solution which prevents data losses and damage to hard disks. The Silent sound suppressor does not impair the system s extinguishing effectiveness. Retrofitting existing systems is possible and recommended. Nozzle Pressure (bar) 50 45 40 35 30 25 20 15 10 5 0 Measurement diagram Reduced sound pressure level Sound Pressure Level without Silencer Nozzle Pressure Sound Pressure Level with Silencer 0 20 40 60 80 100 120 140 160 180 200 220 240 Time (s) The Silent sound suppressor prevents harmful sound pressure levels from forming, even at maximum nozzle pressure. 130 125 120 115 110 105 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5 0 Sound Pressure Level (db (A)) 9

SAFETY THOUGHT ALL THE WAY THROUGH WITH US AT YOUR SIDE WAGNER develops concepts for fire protection and implements them in each and every specific project as a VdS-certified installer. WAGNER s mission is to serve its customers entirely from a single source. Our specialists are available to you from your first consulting session on building the system of your tailor-made fire protection solution all the way to ongoing maintenance. This way, we make sure that the solutions we develop fully meet your protection objectives and comply with all guidelines and approvals which the legislators and insurers require. FirExting has the following VdS system approvals. Nitrogen fire extinguishing system: S303006 and S315002 Argon fire extinguishing system: S303005 and S315001 IG-541 fire extinguishing system: S314015 The optional sound suppressor also have VdS device approval Sound suppressor SILENT: G310025 WAGNER have the following VdS approvals Nitrogen fire extinguishing systems: E1397001 Argon fire extinguishing systems: E1297002 IG-541 fire extinguishing installations: E1113002 10

Certified fire prevention Interxion Germany Always on the safe side WAGNER s holistic thinking includes offering the best service possible. This naturally includes supporting WAGNER gas extinguishing systems beyond installation and commissioning. In our maintenance offer, we provide regular system inspections and check for factors such as changes in room use and system configuration. In short: When it comes to safety, you can always rely 100% on WAGNER! In good company FirExting gas extinguishing systems are used by thousand all over the world today. Thanks to their flexibility and outstanding efficiency, they make a major contribution to the safety of our customers. Tailor-made fire protection with FirExting from WAGNER is used by many big-name companies. 11

FIRE PREVENTION HAZARD MANAGEMENT SYSTEM EARLY FIRE DETECTION WAGNER sets standards for innovative and comprehensive solutions in fire protection: with TITANUS for very early fire detection, FirExting for fire-extinguishing, with OxyReduct to actively prevent fires from breaking out and VisuLAN for hazard management. For more information visit www.wagner.eu. FIRE SUPPRESSION Headquarters Sales International WAGNER Group GmbH Headquarters Schleswigstraße 1 5 D-30853 Langenhagen Germany Phone +49 511 97383 0 info@wagner.de Subsidiaries worldwide Austria WAGNER Austria GmbH Am Hafen 6/1/12 A-2100 Korneuburg Phone +43 2262 64262 0 office@wagner-austria.com Benelux WAGNER Nederland B.V. Computerweg 1 3542 DP Utrecht Postbus 1045 3600 BA Maarssen Phone +31 346 5580 10 info@wagner-nl.com France WAGNER Group GmbH Bureau de liaison France 33 avenue du Maine F-75015 Paris Phone +33 1 4410413 0 info@wagner-france.com Great Britain WAGNER UK Limited Wagner House Unit F South Cambridge Business Park Babraham Road Sawston Cambridge CB22 3JH Phone +44 870 333 6116 info@wagner-uk.com Poland WAGNER Poland Sp. z o.o. ul. Puławska 38 PL 05-500 Piaseczno Phone +48 22 185530 0 info@wagnerpoland.pl Russia WAGNER RU GmbH Businesscentre SMART PARK 117246, Moscow Nauchnij Projezd 14 A, Building 1, Office 4.12. Phone +7 495 96767 69 info@wagner-russia.com Singapore WAGNER Asia No. 61 Tai Seng Avenue #B1-01 Crescendas Print Media Hub Singapore 534167 Phone +65 6296 7828 info@wagner-asia.com Switzerland WAGNER SCHWEIZ AG Industriestrasse 44 CH-8304 Wallisellen Phone +41 44 832540 0 info@wagner-schweiz.ch USA WAGNER Fire Safety, Inc. 135 Beaver Street #402 Waltham, MA 02452 Phone +1 781 899 9100 info@wagner-us.com WAGNER Group GmbH. Subject to technical changes without notice. Art. no. 68-30-1249. Last revised 10/15.