NEW * for buildings 2-24 floors

Similar documents
Single Wall Flue system. Installation manual WARNING. Installation Manual CoxDENS PPs MC-CG-105 EN_892054

Z-DENS Z-FLEX. Polypropylene Vent Systems for High Efficiency Condensing Appliances. Single Wall Rigid Flexible Liner Concentric

SMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD

24V dc Terminals X4. 230Vac Terminals X V dc Electrical connections Volt free Room thermostat on/off

Corr/Guard PRESSURE RATED VENTING SYSTEM IMPORTANT: DO NOT INSTALL WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY.

Flues and chimney systems

PelletVent Multi-fuel venting system. UL 641.

Direct Vent Training & Installation Instructions for Venting 40/50 gallon models Telescoping Vent Kit (standard)

Z-DENS Polypropylene Vent Systems

INSTALLATION OF VENTING SYSTEM COMPONENTS WARNING

Technical Guidance CE Marking of Metal Chimneys and Flues

maximise the sun s energy with warmflow solar Warmflow Solar

C. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009.

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

TW-Pro. Twin Wall Insulated Flue System EN T600 N1 W V2 L50040 G50 / O40

PelletVent Pro horizontal Kit. PelletVent Pro. PelletVent Pro Vertical Kit - Cathedral. PelletVent Pro Pellet Chimney

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

Installation Plan Commercial Rotary Iron PM 1210 PM 1214 PM 1217

Technical and Dimensional Data. Saf-T Vent SC Plus

Twin Wall Installation Instructions And Maintenance Guide

EXHAUST SYSTEMS COMMERCIAL CHIMNEY LINING SYSTEMS.

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS

U tube models PTU 09, 12, 15, 25, 30, 35, 40, 45. single linear tube models PTS 09, 12, 15, 25, 30, 35, 40, 45

RS Chimney Fan for Solid Fuel Applications

Easyfire Standalone biomass pellet boiler

Pellet Stove. Flex Pipe. Appliance Connector

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

BDM Direct Vent systems are for use with direct vent gas fired appliances.

RS Chimney Fan for Solid Fuel Applications

RHC & RHCE gas fired heating coils

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

The intelligent alternative for flue gas venting systems

Easy to assemble. Silicone gasket sealed. Laser-welded seams. Smooth joint connections. 360 Lock-Tab secure rotation

200i. Vent/air manual. Installation instructions for vent and air piping. Also read and follow: 200i Boiler manual 200i Control manual

Light oil / kerosene burner

Combustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641.

Flues and chimney systems

ULC S636 System. PolyPro. PolyPro Flex. Terminations

DURAVENT POLYPRO VENTING PRODUCTS

Technical Specification

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

Vertical Termination Part No: 3CGRVT 16 7/8" 18 Vent Pipe Extension Part No: 3CG18 9 7/8" Wall Hanger Part No: 3CGWH 7 7/8" 7 3/8"

Why our flame is so natural... Our Technology & Engineering Excellence. Efficiency. Safety & Reliability. Fully Remote Controlled

Extraction systems for the electronic industry. Soldering workstations Soldering smoke extraction systems

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

PolyPro: For Venting Condensing Appliances Environmentally Safe Alternative Lower Over-All Cost Than PVC Engineered Terminations Fast, Easy To Install

Light oil - kerosene burner

Type BK 20 BK 30 BK 50

INSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS IMPORTANT

ENERVEX RSV CHIMNEY FAN

Gas Stoves. C34-10 Direct Vent Gas Stove. Side wall E F. Back wall F E. Model C34-NG10 C34-LP10

CANOPY RANGEHOOD ONBOARD INSTALLATION INSTRUCTIONS

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

COMBINATION SOLUTION FOR COLLECTIVE FLUE, AIR VENTILATION AND EXHAUST

PUCCI S.r.l. COMPONENTS AND ACCESSORIES FOR GAS BOILERS 0051 CPD 0080

CHIMNEY INSTALLATION. Technical Bulletin #1

For latest prices and delivery to your door visit MyTub Ltd

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

The New Remeha Quinta Pro Selection, Design and Installation of Flue Systems

Cooker Hood User Manual

CG60/ 70/ 80/ 90/ 100 SS/BK

SB Range Universal Oil Heaters with Automatic Ignition

THE TINY LIGHTWEIGHT

Installation Instructions for use by heating contractor

PUCCI S.r.l. COMPONENTS AND ACCESSORIES FOR GAS BOILERS 0051 CPD CPD 0081

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)

Vent and air piped through a side wall (concentric termination)

Centrometal d.o.o. - Glavna 12, Macinec, Hrvatska, tel: , fax: THE BOILER PelTec 12 WITH SPARE PARTS LIST

Flue & Flue Kits for NVx, VPC & NVS

Hennecke description of day tanks and metering equipment used in conjunction with Rotamats supplied to Trane (Vidalia, GA)

Installation Instructions

HeatMaster. Assembling and installation instructions. 201 Booster. HeatMaster. HeatMaster. 200N (Gas) Booster ENGLISH FRANCAIS NEDERLANDS ESPAÑOL

DuraPlus HTC. All-fuel, double-wall chimney system. ULC S629.

B.C.S. Shop Heaters 26, 30 & 36 (36 shown)

MJ35 Parts List. Accessories. Burner Components. Cabinetry. Thermostats. Filtration. Frypots. Basket Lift. Square Drain Components

TECHNICAL DATA. F.H. Biddle B.V. P. O. Box 15, NL-9288 ZG Kootstertille,The Netherlands. Tel: Fax:

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Condensing Gas Boilers SUGGESTED LIST PRICE (U.S.)

Gas-fired unit heaters for indoor installation

Solar Thermal Energy

By Bernard Dalsin Mfg. Co. Installation and Operating Instructions Read these instructions and keep them for future reference

RS Chimney Fan For Gas & Oil Applications. Installation & Operating Manual USA CAN

CANOPY RANGEHOOD OFFBOARD INSTALLATION INSTRUCTIONS

ASSEMBLY INSTRUCTIONS - NXS SERIES. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

CVS. Venting System for Category II, III, and IV gas appliances. Listed to UL-1738 and ULC S636.

NL Installatievoorschriften p. 3. FR Instructions d installation p. 5. DE Montageanleitung p. 7. EN Operating and installation Instructions p.

OPTIMUM 700 PASTA COOKER ELECTRIC BUILDER S SPECIFICATIONS. Part A: Technical characteristics Part B: Technical instructions for the installer

MINI BENCH TOP CHAMBER MODEL: MI-80-A-H

JEREMIAS GROUP. CE MARK according to EN / 2.

Kompakt HRE eco 12 Solo 18 Solo 30 Solo 40 Solo. Installation instructions. ACV International 1

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings

Gas Storage Water Heaters CONVENTIONAL FLUE FAN FLUED BALANCED FLUE DIRECT STORAGE TANKS

NAVIEN AMERICA INC FITCH AVENUE IRVINE, CALIFORNIA, USA

CHAPTER 8 CHIMNEYS AND VENTS

Transcription:

CFS-NV Communal Flue System - Naturally Vented negative pressure CFS-FA Communal Flue System - Fan-Assisted positive pressure CFSeo-FA Communal Flue System exhaust only - Fan-Assisted NEW * for buildings 2-24 floors

CFS-NV A complete communal flue system, providing air supply to and exhaust gas and condensate removal from, multiple heating and hot water gas fired appliance installations via concentric pipes, all operating under a fully naturally vented negative pressure. CFS-NV is Cox Geelens complete flue system which combines a communal air supply and a communal flue outlet for use with gas fired condensing (HE) and non condensing (SE) boilers. The system operates with negative pressure and fits perfectly with the latest generation gas fired heating appliances, with flue/air connection Ø 80/80, 60/100 and 80/125 mm. The system conforms to the rigorous Gaskeur Test no 138 and is certified by Gastec Qa, cert. no- 96/006 01, report no 175466. It is also CE Marked in accordance with European Standards EN 1856-1. Special features: 3 RooF MoUnTinG plate 1 2 4 RooF TeRMinaL storm collar FLooR bracket The outer aluminium pipe has a fully welded longitudinal seam and is roll grooved for maximum rigidity. The CoxSafe seal applied to the male o/d circumference ensures an airtight male/ female joint at installation assembly. The aluminium inner pipe has a 1.5mm wall thickness, has a longitudinal TIG-welded seam with its female end fitted with the latest Fix-Safe seal(fs) for a gas-tight and condensate-tight push fit joint. 6 T-piece FiX - safe 5 FLUe and air pipe The elasticity of the Fix-Safe seal combined with its unique design ensures optimum sealing performance. The system can sustain an average of 20-35 kw for condensing (HE) boilers and 24-42 kw for non-condensing (SE) boilers. Each CFS-NV system is supplied as a complete kit of parts to build the complete assembly installation comprising: roof terminal, roof mounting plate or flat flashing with storm collar, concentric T-pieces with appropriate number of connections per storey, concentric twin sections, condensate collector base unit, floor brackets and floor supports. As an aid to section assembly we recommend applying soapy film to the joint seal surfaces prior to push fit connection (obtainable from Cox Geelen). FLooR 4 6 7 FLooR bracket T-piece condensate collector base UniT WiTH adjustable FLooR support

RooF TeRMinaL T-piece 2 connections D1 D2 D4 0 M L H MIN 140 280 400 220 315 200 1035 160 315 450 248 315 225 1088 180 355 507 279 315 254 1148 200 400 570 314 315 286 1215 225 450 643 353 315 321 1289 250 500 714 393 315 357 1365 280 560 800 440 315 400 1455 315 630 900 495 315 450 1560 355 710 1014 558 315 507 1680 400 800 1143 628 315 571 1814 FLUe and air pipe H FLOOR L 2700 MM 1300 MM 2750 MM 1350 MM 2800 MM 1400 MM 2850 MM 1450 MM 2900 MM 1500 MM 2950 MM 1550 MM detail connection (WiTH GUide plate) Ø 80/80 Ø 60/100 Ø 80/125 FiX - safe FLAT ROOF SLOPING ROOF condensate collector base UniT WiTH adjustable FLooR support Fix the height from the roof top till the middle of the last T-piece Fix the right roof angle

CFS-NV CFS-FA D1 / D2 20 kw HE 24 kw SE 140/280 2 2 T-piece WiTH 1-2-3-4 connections T-piece 2 connections FLooR bracket detail assembly of FLUe/aiR pipe and T-piece PIPE DIAMETER IN RELATION WITH THE NUMBER OF APPLIANCES 25 kw HE 30 kw SE 160/315 3/4/5 3 2 30 kw HE 36 kw SE 180/355 6/7 4/5 3/4 2/3 200/400 8/9/10 6/7 5/6 4/5 225/450 11/12/13 8/9/10 7/8 6/7 250/500 14/15/16 11/12/13 9/10/11 8/9 35 kw HE 42 kw SE 280/560 17/18/19/20 14/15/16 13/13/14 10/11/12 315/630 17/18/19/20 15/16/17 13/14/15 355/710 18/19/20 16/17/18 400/800 19/20 A complete communal flue system, providing air supply to and exhaust gas and condensate removal from, multiple heating and hot water gas fired appliance installations via concentric pipes. Fan assisted, positive pressure operation allows the system to become more space saving for an extra compact installation. CFS-FA is Cox Geelens complete flue system which combines a communal air supply and a communal flue outlet for use with gas fired condensing (HE) and non condensing (SE) boilers with flue/air connection Ø 80/80, 60/100 and 80/125 mm, that are fitted with non-return valves. The system operates with positive pressure and the non-return valve arrangement on each boiler connection is essential to prevent recirculation of exhaust gases to non operational appliances. This system is also CE Marked in accordance with European Standards EN 1856-1. Special features: The outer aluminium pipe has a fully welded longitudinal seam and is roll grooved for maximum rigidity. The CoxSafe seal applied to the male o/d circumference ensures an airtight male/female joint at installation assembly. The aluminium inner pipe has a 1.5 mm wall thickness, has a longitudinal TIG-welded seam with its female end fitted with the latest Fix-Safe seal (FS) for a gas-tight and condensate-tight push fit joint. The elasticity of the Fix-Safe seal combined with its unique design ensures optimum sealing performance. Each CFS-FA system is supplied as a complete kit of parts to build the complete assembly installation comprising: roof terminal with storm collar, tile with lead flashing or flat flashing, concentric T-piece with appropriate number of connections per storey, concentric twin sections, condensate collector base unit, floor brackets and floor supports. As an aid to section assembly we recommend applying soapy film to the joint seal surfaces prior to push fit connection (obtainable from Cox Geelen). condensate collector base UniT detail connection (WiTHoUT GUide plate) Concentric diameter data is specific to the number of appliances connected and is available upon request. For other CFS-FA parts, please refer to the CFS-NV section in this brochure.

CFSeo-FA A complete communal flue system, providing exhaust gas and condensate removal only from multiple heating and hot water gas fired appliance installations. Fan assisted positive pressure operation allows the system to become more space saving where local room sealed air supply is preferred. CFSeo-FA is Cox Geelens single pipe complete flue exhaust system for use with room sealed gas fired condensing (HE) and non condensing (SE) boilers and fits perfectly with the latest generation gas fired heating appliances with flue connection Ø 60 and 80 mm. This system is also CE Marked in accordance with European Standards EN 1856-1. Special features: The aluminium pipe has a 1.5mm wall thickness, has a longitudinal TIG-welded seam with its female end fitted with the latest Fix- Safe seal (FS) for a gas-tight and condensate-tight push fit joint. The elasticity of the Fix-Safe seal combined with its unique design ensures optimum sealing performance. The system can sustain an average of 20-35 kw for condensing (HE) boilers and 24-42 kw for non-condensing (SE) boilers. CFSeo-FA system is supplied as a complete kit of parts to build the complete assembly installation comprising: Trega terminal with storm collar tile with lead flashing or flat flashing single pipe T-pieces with appropriate number of connections per storey, single pipe parallel sections, condensate collector base unit, floor brackets and floor supports. As an aid to section assembly we recommend applying soapy film to the joint seal surfaces prior to push fit connection (obtainable from Cox Geelen).

CFSeo-FA Ø 80 Ø 130 L=1550 PIPE DIAMETER IN RELATION WITH THE NUMBER OF APPLIANCES D1 20 KW HE 24 KW SE 25 KW HE 30 KW SE 30 KW HE 36 KW SE 35 KW HE 42 KW SE 130 2 2 150 3/4/5 3 2 180 6/7 4/5 3/4 2/3 200 8/9/10 6/7 5/6 4/5 225 11/12/13 8/9/10 7/8 6/7 250 14/15/16 11/12/13 9/10/11 8/9 280 17/18/19/20 14/15/16 12/13/14 10/11/12 300 17/18/19/20 15/16/17 13/14/15 350 18/19/20 16/17/18 400 19/20 For > 20 appliances, the applicable pipe diameters are available on request. FLUe pipe H FLOOR L 2700 MM 1300 MM 2750 MM 1350 MM 2800 MM 1400 MM 2850 MM 1450 MM 2900 MM 1500 MM 2950 MM 1550 MM For other CFSeo-FA parts, please refer to the CFS-NV section in this brochure. condensate base UniT WiTH adjustable FLooR support BK-CG-002 01-2016-500 Cox Geelen Emmastraat 92 6245 HZ Eijsden PO-Box 6 6245 ZG Eijsden The Netherlands T +31 (0)43 40 99 500 F +31 (0)43 40 91 987 sales@coxgeelen.com www.coxgeelen.com KvK Zuid-Limburg 14608324