TDEVCDP02 April 2009 EVCDP Conventional Dual Optical Detector NITTAN EVCDP Conventional Evolution Dual Optical Detector. F02J82205 Technical Specifications:Sensor Method Sensor Element Operating Voltage System Voltage Quiescent Current Alarm Current Current for external remote LED indicator Operating Temperature Storage Temperature Charging Time Relative Humidity I.P. Protection Rating Material Dimensions Mass Light Scatter 2 x Light Emitting Diode 12V d.c. to 32V d.c. 40µA at 24v 50mA at 24v 5mA 20 C to + 60 C 1 minute in Clean Air RH95% noncondensing. IP42 /PC alloy 104mm x 33mm (Sensor head) 104mm x 48mm (Sensor head and STB4) 118g (Sensor head) 183g (Sensor head and STB4 base) EN547: 2000 EN547: 2000 From Control Panel 104 Negative Positive 1 3 6 Base : STB4 STB4SD 5 RIL Refer the connection manual 48 + To Next Device
TDEVCP06 April 2009 EVCP Conventional Optical Sensor EVCP Conventional Evolution Optical Sensor. F03C82200 Technical Specifications:Sensor Method Sensor Element Operating Voltage System Voltage Quiescent Current Alarm Current Current for external remote LED indicator Operating Temperature Storage Temperature Charging Time Relative Humidity I.P. Protection Rating Material Dimensions Mass Light Scatter 1 x Light Emitting Diode 12V d.c. to 32V d.c. 50µA 50mA 2mA 20 C to + 60 C 20 Seconds RH95% noncondensing. IP40 104mm x 33mm (Sensor head) 104mm x 48mm (Sensor head and UB4) 118g (Sensor head) 183g (Sensor head and UB4 base) EN547 : 2000 EN547: 2000 From Control Panel 104 Negative Positive 1 3 6 Base : STB4 STB4SE UB4 UB4SD 5 RIL Vdd 48 + To Next Device
TDEVCPYIS03 EVCPYIS Conventional Intrinsically Safe Optical Detector December 2009 EVCPYIS Evolution Conventional Intrinsically Safe Optical Detector F02N83300 Technical Specifications:Sensor Method Sensor Element Operating Voltage System Voltage Quiescent Current Alarm Current Current for external remote LED indicator Operating Temperature Storage Temperature Charging Time Relative Humidity I.P. Protection Rating Material Dimensions Mass Light Scatter 1 x Light Emitting Diode 10V d.c. to 32V d.c. 50µA at 24v 50mA at 24v limited by barrier to 0.66W in I.S. zone 2mA 20 C to + 50 C (Limited by ATEX Certification) 1 Minute RH95% noncondensing. IP42 104mm x 33mm (Sensor head) 104mm x 48mm (Sensor head and UB4IS base) 110g (Sensor head) 170g (Sensor head and UB4IS base) BSEN501304 EN547 0786CPD20883 Class 1G (Gas), T4 (Temperature) ITS09ATEX26418X CPD Number ATEX Certification ATEX Cert Number From Control Panel 104 Negative Positive 1 2 6 5 Base : UB4IS RIL Vdd 48 + To Next Device
TDEVCH03 April 2009 EVCH Conventional Heat Detector EVCH Conventional Heat Detector. Class A2S F04N82505 Class CS F04N82507 Technical Specifications:Sensor Element Operating Voltage System Voltage Quiescent Current Alarm Current Current for external remote LED indicator Typical Application Temperature Maximum Application Temperature Min. and Max. Static Response Temperature Minimum Ambient Temperature Storage Temperature Charging Time Relative Humidity I.P. Protection Rating Material Dimensions Mass Thermister 11V d.c. to 32V d.c. 30µA 50mA@ 24v Limit to 20mA max A2S: 25 C, CS: 55 C A2S: 50 C, CS: 80 C A2S: 54 C / 70 C, CS: 84 C / 100 C Both 10 C 25 C to + 90 C 30 Seconds RH95% noncondensing. IP40 105mm x 42.5mm (Sensor head) 105mm x 57.5mm (Sensor head and UB4) 118g (Sensor head) 183g (Sensor head and UB4 base) EN545 including EMC conformance to BSEN501304. EN545 Base : STB4 STB4SE UB4 UB4SD
TDEVCH03 April 2009 EVCH Conventional Heat Detector EVCH Conventional Heat Detector. Class A2S F04N82505 Class CS F04N82507 Technical Specifications:Sensor Element Operating Voltage System Voltage Quiescent Current Alarm Current Current for external remote LED indicator Typical Application Temperature Maximum Application Temperature Min. and Max. Static Response Temperature Minimum Ambient Temperature Storage Temperature Charging Time Relative Humidity I.P. Protection Rating Material Dimensions Mass Thermister 11V d.c. to 32V d.c. 30µA 50mA@ 24v Limit to 20mA max A2S: 25 C, CS: 55 C A2S: 50 C, CS: 80 C A2S: 54 C / 70 C, CS: 84 C / 100 C Both 10 C 25 C to + 90 C 30 Seconds RH95% noncondensing. IP40 105mm x 42.5mm (Sensor head) 105mm x 57.5mm (Sensor head and UB4) 118g (Sensor head) 183g (Sensor head and UB4 base) EN545 including EMC conformance to BSEN501304. EN545 Base : STB4 STB4SE UB4 UB4SD
UB4 Mounting Base Nittan Standard UB4 Mounting base for Detectors Indoor mounting base F03_83500 Operating Temperature Storage Temperature Relative Humidity Material Dimensions Mass RH95% noncondensing. 104.50mm x 15.00mm 52g EMC conformance to BSEN501304 Complies with EN545,7 Addressable Termination 1 = +VE 3 = RIL VE 2mA 5 = Screen 6 = VE Conventional Termination 1 = VE in 3 = + VE in/out 5 = RIL VE 2mA 6 = VE out TDUB4 01 May 2012
UB4SD Base Nittan Standard UB4SD Mounting base for Detectors Indoor mounting base F03_83510 Operating Temperature Storage Temperature Relative Humidity Material Dimensions Mass RH95% noncondensing. 104.50mm x 15.00mm 52g EMC conformance to BSEN501304 Complies with EN545,7 Conventional Termination 1 = VE in 3 = + VE in/out 5 = RIL VE 20mA 6 = VE out TDUB4SD 01 June 2012
UB4SDR470 Mounting Base Nittan Standard UB4SDR470 Mounting base for Detectors Indoor mounting base F03_83512 Operating Temperature Storage Temperature Relative Humidity Material Dimensions Mass RH95% noncondensing. 104.50mm x 15.00mm 54g EMC conformance to BSEN501304 Complies with EN545,7 Conventional Termination 1 VE in 4 + VE in/out 5 RIL VE 6 VE out TDUB4SDR470 01 June 2012
UB4R470 Mounting Base Nittan Standard UB4R470 Mounting base for Detectors Indoor mounting base F03_83503 Operating Temperature Storage Temperature Relative Humidity Material Dimensions Mass RH95% noncondensing. 104.50mm x 15.00mm 54g EMC conformance to BSEN501304 Complies with EN545,7 Conventional Termination 1 VE in 4 + VE in/out 5 RIL VE 6 VE out TDUB4R470 01 June 2012
TDSTB4SESWEV 01 STB4SESWEV Savwire Base Nittan Standard STB4SESWEV Savwire base for EV Detectors Indoor savwire base F03_84010 Operating Temperature Storage Temperature Relative Humidity Material Dimensions Mass RH95% noncondensing. 104.50mm x 23.00mm 78g EMC conformance to BSEN501304 Complies with EN545,7 Terminations: 2 = +VE 1 = VE 5 = RIL VE May 2012
SENSORTEC TDSTB4SE01 STB4SE Standard Deep Base Nittan Standard STB4SE Standard Deep Base Indoor mounting base F03_82300 Operating Temperature Storage Temperature Relative Humidity Material Dimensions Mass 12 to 38V d.c. RH95% noncondensing. 104.50mm x 23.00mm 78g EMC conformance to BSEN501304 Complies with EN545,7 Conventional Termination Analogue Termination 1 VE in 3 +VE In/Out 5 RIL VE 20mA Max 6 VE Out 1 +VE 6 VE 3 RIL VE 2mA 5 Earth May 2012
SENSORTEC STB4SESD Base Nittan Standard STB4SESD Diode Deep Base Indoor mounting base F03_82302 Operating Temperature Storage Temperature Relative Humidity Material Dimensions Mass RH95% noncondensing. 104.50mm x 23.00mm 78g EMC conformance to BSEN501304 Complies with EN545,7 Conventional Termination 1 VE in 3 +VE In/Out 5 RIL VE 20mA Max 6 VE Out TDSTB4SESD 01 May 2012