NITTAN. EVOLUTION April 2009 EVC-DP Conventional Dual Optical Detector TECHNICAL DATASHEET. Part Numbers and Product Order Codes:Part Number

Similar documents
evolution EV-H ANALOGUE ADDRESSABLE HEAT SENSOR INSTRUCTION MANUAL LPCB REF: 041h/01&02 and 842c/03&04

EVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR. instruction manual. evolution EVC-P Conventional Photoelectric Smoke Detector

Evolution Product Range

NAM-AS3 LOOP POWERED INPUT MODULE INSTALLATION & TECHNICAL MANUAL

SOUNDER CONTROL MODULE SCM-AS4

Conventional Smoke Detectors KFAPO

SERIES 65 ENGINEERING PRODUCT GUIDE

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

SERIES 65 ENGINEERING PRODUCT GUIDE

Series 65 Product Guide MAN 3036

Evolution Analogue Addressable Fire System

DUR 40Ex Intrinsically Safe SMOKE DETECTOR

Analogue addressable devices

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

Emergi-Lite Orbis detectors

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

Orbis IS Product Guide MAN 3041

MULTISENSOR SMOKE AND HEAT DETECTOR DMP-100 OPTICAL SMOKE DETECTOR DRP-100 FIXED TEMPERATURE / RATE-OF-RISE HEAT DETECTOR DCP-100

ORBIS PRODUCT GUIDE. Optical Detector. Multisensor Detector. Heat Detector. Mounting Bases

SAL 4001 ADDRESSABLE ACCOUSTIC SIGNALLING DEVICE

FDOOT241-A9-Ex Multisensor fire detector

Standard detectors. General information. Product Sheet Detec on

Touch Screen 1 loop Addressable Fire Alarm Panel

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

optical detector multisensor detector heat detector mounting bases product guide

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

CONTENTS NBM-06 Bell (6") Page 1

Fire & Security Products. Siemens Building Technologies Group

XP95 Intrinsically Safe Product Guide MAN 3054

Salsmästaregatan 21 P.O. Box 8763 SE Gothenburg

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

DICTATOR Hold-Open Systems for Hazardous Areas

LOW POWER VERSION DUAL HYDROCARBONS AND CARBON DIOXIDE SENSOR Exd Certified VERSIONS *** Available in EN50271 / SIL1 Certified versions ***

PREMIER PLATINUM INFRARED GAS SENSOR

General Routing Interface

EFBW series - BiWire Ultra control panel

Interbases. Sinteso FDSB221, FDSB228, FDSB229

PREMIER PLATINUM INFRARED TRIPLE RANGE HYDROCARBON SENSOR Exd Certified versions *** Available in EN50271 / SIL1 Certified versions ***

OH110, OP110, HI110 Automatic fire detectors

MR300 OPTICAL SMOKE DETECTOR RANGE PRODUCT APPLICATION & DESIGN INFORMATION

Reflective Optical Beam Smoke Detector User Guide

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION

OOH740-A9-Ex Multi-sensor fire detector

OOH740-A9-Ex Multisensor fire detector

Product Overview. Ordering Information DM-LK-D10 DM-LK-D10-C. Dust & Opacity Meter Complete Set Controller Unit. Sender Receiver SDS-V5 SDR-V4 HPB-82S

Engineering Product Guide Ionisation Smoke Detectors Optical Smoke Detectors Resettable Heat Detectors

Room controller. RC is a room controller from the Regio Mini series intended to control heating and cooling in a single zone.

XP95 ENGINEERING PRODUCT GUIDE

OH720, OP720, HI720, HI722

System 800 Addressable Fire Detection & Alarm System

Gas cylinder scale Model GCS-1

Installation and Operating Instruction

FIRE DETECTOR TYPE ED816 ZONE 5 ZONE 4 ZONE 6 ZONE 7 FIRE FIRE FIRE FIRE FAULT FAULT FAULT FAULT DISABLED DISABLED DISABLED DISABLED OFF OFF OFF OFF

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

Technical data sheet TDS0034

Technical Data. General specifications. Rated operating distance s n 5 mm

Room controllers with manual forced ventilation function

Flame Safeguards LFE10. Building Technologies HVAC Products

OPERATION AND INSTALLATION MANUAL

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

ALARMLINE ANALOGUE Linear Heat Detection System

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops...

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data Sheet 5mm Infrared LED, T-1

VL18LL-M/40a/118/128. VL18LL-M/40a/118/128. Fibre optic sensor for glass fibre optics. with M12, 4-pin metal connector

Input/Output Modules Data Sheet

Instruction Manual EVA-STB-RL

HOA0880-T51. Representative photograph, actual product appearance may vary.

Interface Modules for SENTRI

Flame Safeguards LFE10. Building Technologies HVAC Products

The new detector from Rafiki

QRA4.U. Flame Detector. Siemens Building Technologies HVAC Products

XP95 Product Guide MAN 3037

Technical data sheet TDS0060

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

RFM Series RFM-ISR Barrier. Installation Manual

Flame detector. The QRA4.U is for use with the following types of burner control:

BKA-EN Fire Damper. Additional operating instructions according to

On the job around the clock 24/7: Fire detection systems

Flame detector. The QRA4.U is for use with the following types of burner control:

Pyroelectric Infrared Radial Sensor

INSTRUCTION MANUAL (ATEX / IECEx)

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Class 1 laser beam sensor safe for your eyes

Conventional Fire Alarm System 2014 V1.2

LAE10 LFE10. Use. Series 02

BSK-RPR Fire Damper. Additional operating instructions according to

FIRE ALARM CONTROL PANEL. COMPLIES WITH EN54 part 2 & part 4 MEETS THE FUNCTIONAL REQUIREMENT OF BS:EN 5839 part 1 INSTALLATION MANUAL

MXD75 Multi Channel Suspended Solids and Turbidity Transmitter

Rules for Intruder Alarm Systems

Surveyor Envoy-MINI 4

Sita200plus. 200detectors. Single loop analogue addressable System

INPUT / OUTPUT MINI MODULES

Quadruple-beam photoelectric detector

Topscan G3 Presence detector for automatic doors

Flame detector. Building Technologies Division Infrastructure & Cities Sector

909e Series 2/4 Zone Panel. Operating and Configuration. Manual Version V01

FDCL221 Line separator

Fire Signalling. Signalling Solutions

Transcription:

TDEVCDP02 April 2009 EVCDP Conventional Dual Optical Detector NITTAN EVCDP Conventional Evolution Dual Optical Detector. F02J82205 Technical Specifications:Sensor Method Sensor Element Operating Voltage System Voltage Quiescent Current Alarm Current Current for external remote LED indicator Operating Temperature Storage Temperature Charging Time Relative Humidity I.P. Protection Rating Material Dimensions Mass Light Scatter 2 x Light Emitting Diode 12V d.c. to 32V d.c. 40µA at 24v 50mA at 24v 5mA 20 C to + 60 C 1 minute in Clean Air RH95% noncondensing. IP42 /PC alloy 104mm x 33mm (Sensor head) 104mm x 48mm (Sensor head and STB4) 118g (Sensor head) 183g (Sensor head and STB4 base) EN547: 2000 EN547: 2000 From Control Panel 104 Negative Positive 1 3 6 Base : STB4 STB4SD 5 RIL Refer the connection manual 48 + To Next Device

TDEVCP06 April 2009 EVCP Conventional Optical Sensor EVCP Conventional Evolution Optical Sensor. F03C82200 Technical Specifications:Sensor Method Sensor Element Operating Voltage System Voltage Quiescent Current Alarm Current Current for external remote LED indicator Operating Temperature Storage Temperature Charging Time Relative Humidity I.P. Protection Rating Material Dimensions Mass Light Scatter 1 x Light Emitting Diode 12V d.c. to 32V d.c. 50µA 50mA 2mA 20 C to + 60 C 20 Seconds RH95% noncondensing. IP40 104mm x 33mm (Sensor head) 104mm x 48mm (Sensor head and UB4) 118g (Sensor head) 183g (Sensor head and UB4 base) EN547 : 2000 EN547: 2000 From Control Panel 104 Negative Positive 1 3 6 Base : STB4 STB4SE UB4 UB4SD 5 RIL Vdd 48 + To Next Device

TDEVCPYIS03 EVCPYIS Conventional Intrinsically Safe Optical Detector December 2009 EVCPYIS Evolution Conventional Intrinsically Safe Optical Detector F02N83300 Technical Specifications:Sensor Method Sensor Element Operating Voltage System Voltage Quiescent Current Alarm Current Current for external remote LED indicator Operating Temperature Storage Temperature Charging Time Relative Humidity I.P. Protection Rating Material Dimensions Mass Light Scatter 1 x Light Emitting Diode 10V d.c. to 32V d.c. 50µA at 24v 50mA at 24v limited by barrier to 0.66W in I.S. zone 2mA 20 C to + 50 C (Limited by ATEX Certification) 1 Minute RH95% noncondensing. IP42 104mm x 33mm (Sensor head) 104mm x 48mm (Sensor head and UB4IS base) 110g (Sensor head) 170g (Sensor head and UB4IS base) BSEN501304 EN547 0786CPD20883 Class 1G (Gas), T4 (Temperature) ITS09ATEX26418X CPD Number ATEX Certification ATEX Cert Number From Control Panel 104 Negative Positive 1 2 6 5 Base : UB4IS RIL Vdd 48 + To Next Device

TDEVCH03 April 2009 EVCH Conventional Heat Detector EVCH Conventional Heat Detector. Class A2S F04N82505 Class CS F04N82507 Technical Specifications:Sensor Element Operating Voltage System Voltage Quiescent Current Alarm Current Current for external remote LED indicator Typical Application Temperature Maximum Application Temperature Min. and Max. Static Response Temperature Minimum Ambient Temperature Storage Temperature Charging Time Relative Humidity I.P. Protection Rating Material Dimensions Mass Thermister 11V d.c. to 32V d.c. 30µA 50mA@ 24v Limit to 20mA max A2S: 25 C, CS: 55 C A2S: 50 C, CS: 80 C A2S: 54 C / 70 C, CS: 84 C / 100 C Both 10 C 25 C to + 90 C 30 Seconds RH95% noncondensing. IP40 105mm x 42.5mm (Sensor head) 105mm x 57.5mm (Sensor head and UB4) 118g (Sensor head) 183g (Sensor head and UB4 base) EN545 including EMC conformance to BSEN501304. EN545 Base : STB4 STB4SE UB4 UB4SD

TDEVCH03 April 2009 EVCH Conventional Heat Detector EVCH Conventional Heat Detector. Class A2S F04N82505 Class CS F04N82507 Technical Specifications:Sensor Element Operating Voltage System Voltage Quiescent Current Alarm Current Current for external remote LED indicator Typical Application Temperature Maximum Application Temperature Min. and Max. Static Response Temperature Minimum Ambient Temperature Storage Temperature Charging Time Relative Humidity I.P. Protection Rating Material Dimensions Mass Thermister 11V d.c. to 32V d.c. 30µA 50mA@ 24v Limit to 20mA max A2S: 25 C, CS: 55 C A2S: 50 C, CS: 80 C A2S: 54 C / 70 C, CS: 84 C / 100 C Both 10 C 25 C to + 90 C 30 Seconds RH95% noncondensing. IP40 105mm x 42.5mm (Sensor head) 105mm x 57.5mm (Sensor head and UB4) 118g (Sensor head) 183g (Sensor head and UB4 base) EN545 including EMC conformance to BSEN501304. EN545 Base : STB4 STB4SE UB4 UB4SD

UB4 Mounting Base Nittan Standard UB4 Mounting base for Detectors Indoor mounting base F03_83500 Operating Temperature Storage Temperature Relative Humidity Material Dimensions Mass RH95% noncondensing. 104.50mm x 15.00mm 52g EMC conformance to BSEN501304 Complies with EN545,7 Addressable Termination 1 = +VE 3 = RIL VE 2mA 5 = Screen 6 = VE Conventional Termination 1 = VE in 3 = + VE in/out 5 = RIL VE 2mA 6 = VE out TDUB4 01 May 2012

UB4SD Base Nittan Standard UB4SD Mounting base for Detectors Indoor mounting base F03_83510 Operating Temperature Storage Temperature Relative Humidity Material Dimensions Mass RH95% noncondensing. 104.50mm x 15.00mm 52g EMC conformance to BSEN501304 Complies with EN545,7 Conventional Termination 1 = VE in 3 = + VE in/out 5 = RIL VE 20mA 6 = VE out TDUB4SD 01 June 2012

UB4SDR470 Mounting Base Nittan Standard UB4SDR470 Mounting base for Detectors Indoor mounting base F03_83512 Operating Temperature Storage Temperature Relative Humidity Material Dimensions Mass RH95% noncondensing. 104.50mm x 15.00mm 54g EMC conformance to BSEN501304 Complies with EN545,7 Conventional Termination 1 VE in 4 + VE in/out 5 RIL VE 6 VE out TDUB4SDR470 01 June 2012

UB4R470 Mounting Base Nittan Standard UB4R470 Mounting base for Detectors Indoor mounting base F03_83503 Operating Temperature Storage Temperature Relative Humidity Material Dimensions Mass RH95% noncondensing. 104.50mm x 15.00mm 54g EMC conformance to BSEN501304 Complies with EN545,7 Conventional Termination 1 VE in 4 + VE in/out 5 RIL VE 6 VE out TDUB4R470 01 June 2012

TDSTB4SESWEV 01 STB4SESWEV Savwire Base Nittan Standard STB4SESWEV Savwire base for EV Detectors Indoor savwire base F03_84010 Operating Temperature Storage Temperature Relative Humidity Material Dimensions Mass RH95% noncondensing. 104.50mm x 23.00mm 78g EMC conformance to BSEN501304 Complies with EN545,7 Terminations: 2 = +VE 1 = VE 5 = RIL VE May 2012

SENSORTEC TDSTB4SE01 STB4SE Standard Deep Base Nittan Standard STB4SE Standard Deep Base Indoor mounting base F03_82300 Operating Temperature Storage Temperature Relative Humidity Material Dimensions Mass 12 to 38V d.c. RH95% noncondensing. 104.50mm x 23.00mm 78g EMC conformance to BSEN501304 Complies with EN545,7 Conventional Termination Analogue Termination 1 VE in 3 +VE In/Out 5 RIL VE 20mA Max 6 VE Out 1 +VE 6 VE 3 RIL VE 2mA 5 Earth May 2012

SENSORTEC STB4SESD Base Nittan Standard STB4SESD Diode Deep Base Indoor mounting base F03_82302 Operating Temperature Storage Temperature Relative Humidity Material Dimensions Mass RH95% noncondensing. 104.50mm x 23.00mm 78g EMC conformance to BSEN501304 Complies with EN545,7 Conventional Termination 1 VE in 3 +VE In/Out 5 RIL VE 20mA Max 6 VE Out TDSTB4SESD 01 May 2012