Who we are? - Nº 1 Spanish fire alarm systems manufacturer years experience in the fire detection field countries worldwide.

Similar documents
Who we are? Spanish fire alarm systems manufacturer. Engineering team with more than 20 years of experience in the fire detection field.

Our technology, your peace-of-mind. Product list

Intelligent addressable fire alarm control panel

Solution F2. Fire Alarm Control Panels one step ahead.

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Different types of Fire Alarm System

System 800 Addressable Fire Detection & Alarm System

Touch Screen 1 loop Addressable Fire Alarm Panel

Advanced FireAlarm Panel 1-4Loop

Intelligent Security & Fire Ltd

Intelligent Addressable Fire Alarm System

Reliably Advanced Extinguishing Control

HART XL High Sensitivity Smoke Detection

HART XL High Sensitivity Smoke Detection

Fire control panels FC360

Installation, Operating and Maintenance Manual

Reliably Advanced Extinguishing Control

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

FC724 Fire control panel

IMQ SPA scope as CertAlarm CCB and RTL. Last update: 12th June 2017

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

DATAssure. Laboratory wireless alarm & monitoring system

(68.52) X. June 2000 supersedes February vigilon ADVANCED FIRE DETECTION & ALARM SYSTEMS

Industrial Grade Gas Detection Detecting The Difference

For Complete Fire and Gas Solutions

Consultant Specification AGILE Wireless Fire Detection System

CODESEC FIRE ALARM SYSTEMS. security technologies

APPLICATION DATA SHEET

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

FC724 Fire control panel

Addressable and Conventional Fire Protection

FEC400 Series. Installation Manual

Fire control panels FC726 FC726-XA

FC722 Fire control panel

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

FC722 Fire control panel

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

FC723 Fire control panel

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

SISTEMAS DE SEGURIDAD MIRA, S.L. COMPANY & PRODUCT GUIDE

APPLICATION DATA SHEET

D3 Wireless temperature alarm & monitoring system family. tek-troniks

IntesisBox BACnet/IP Server - Notifier ID3000 series

Modular Fire Panel 5000 Series Just as flexible as your plans

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Sita200plus. 200detectors. Single loop analogue addressable System

SUPREMATouch. Modular Fire & Gas Detection System

ACTIVE INFRARED BARRIER

FC2020 Fire control panel

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

ZXSe Range Data Sheet

Control Panels and Fire Detection Equipment

intelligent fire alarm ID60series panels

GST Headquarters. GST Production Base

YOUR PARTNER IN FIRE & GAS DETECTION

MULTIFUNCTIONAL SYSTEM

Fire Product Catalog

Evolution Analogue Addressable Fire System

Engineer Paging. Staff Paging. Deaf Alert.

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

SAFETY/ SECURITY - FIRE FIGHTING INTEGRATED SYSTEMS

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

Aspir A ation spir P R O D U C T S

Wireless Fire & Security Solutions. Fire Product Showcase

SUPREMATouch Modular Fire & Gas Detection System

Basic Fire Alarm SystemTraining. Arman Alnasar

Products and performance

C E R T I F I C AT LPCB I O N B O A R D P R E V E N T L O S S. Cooper Fire Systems

IGD.CO.UK

WIRELESS SOLUTIONS FOR RESIDENCES. A Group brand

General Routing Interface

Security Alarm Systems

All the control in the palm of your hand. hardware software support

intelligent solutions

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2

WW Ability to connect standalone minives units. Integrated mini PA/VA unit. We make everyday life safer. (incl. fireman and zone microphones)

Conventional & Twin-wire Fire System

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

ADR Analog Addressable Fire Alarm Control Panel. Technical Manual. Control Panels. 3000En. En pdf

ID50series. intelligent fire alarm panels

Process Alarm Solutions

Quick Selection Guide Fire Systems LSN Periphery

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

The new detector from Rafiki

FlexPS. Architectural & Engineering. Specification for FlexPS. Architectural/Engineering Specification for a

Fire alarm system EBL512 G3

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

Fire control panel for modernization

Integrated Security Solutions

FIRE ALARM SOLUTIONS THAT FIT YOUR NEEDS

ID3000 intelligent. fire alarm panel

FiberSystem. Fiber Optic Linear Heat Detection for Special Hazard Applications

P R O D U C T D ATA S H E E T

IQ8Control C Fire Alarm Panel

The Kentec driver connects to the Kentec Syncro range of fire detection panels. Available for Commander and ObSys.

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

SUPREMATouch. Modular Fire & Gas Detection System

Transcription:

Who we are? - Nº 1 Spanish fire alarm systems manufacturer. - 25 years experience in the fire detection field. - 40 countries worldwide. Own engineering, design and factories. Total control of production and quality. 100% products approved and tested before delivery. 100% raw material & components used made in Barcelona. 2

European Group Finsecur: Nº 1 Wireless Fire detection manufacturer (France) TheFireBeam: Nº 1 advanced Fire beam detector manufacturer (UK) Detnov: Nº 1 fire alarm systems manufacturer (Spain) 3

BCB Factories in BARCELONA Clean laboratories (1/2) Automatic PCB samsung machines factory in Barcelona. Control panel PCB manufactury capacity : 1 MILION units/ year 0% errors after automatic software and visual quality control.

BCB Factories in BARCELONA Clean laboratories (2/2) Detectors PCB manufactury capacity : 2 MILION units/ year Nordon Controled PCB Welding chamber. Acurate Manual PCB mounting process for big components by specialised and high qualified engineers.

TESTING facilities 100% of DETNOV products Tested in FACTORY: Detectors calibration in Barcelona. Products tested 24 hours before delivery. Raw material quality test.

R&D engineering and innovation PCB Design and Engineering Owned by DETNOV engineers highly qualified 2-3 innovative new product launched each year

ADDRESSABLE CONVENTIONAL EXTINGUISHING CO DETECTION 8

DETNOV strength Smartest commisioning configuration system in the market. European Approvals for all product. 24 hours Service 365 days year. Design Criteria: Minimum Visual impact Competitive price 9

Market References Hotel Industrial Commercial Universities Banks Sports 10

Reference of the year DETNOV Project reference 2016-2017 Whole KozaPark SMART CITY equiped with DETNOV fire alarm system: In Turkey 110,000 square meters, consisting 7 blocks and 105 elite shops. 11

Addressable system 12

Loop Power 250 addresses/loop, in any combination of devices. Conventional and Extinguishing panels in the loop Sounder loop capacity (max. 50) 2Kms loop lenght Non polarity * *For devices without isolator 13

Addressable Control Panels Models CAD-150-1 Mini: 1 loop (100 addresses) CAD-150-1: CAD-150-2: 1 loop (250 addresses) 2 loops (500 addresses) CAD-150-4: 4 loops (1000 addresses) CAD-150-8: 4 loops expandable to 6 and 8 8 loops (2000 addresses) CAD-150-8 Plus: Big battery capacity 14

Addressable Control Panels Connectivity TRED-150: RS485 board TFID-150: Fiber optic board 32 control panels network 1 Km distance 15

Modbus integration RS485 communication output BMS integration Integration with other security systems 100% open communication protocol 16

Addressable detectors DOD-220A: Optical smoke detector DTD-210A: Heat detector (58ºC/8ºC min.) DTD-215A: High heat detector (78ºC) DOTD-230A: Smoke and heat detector Elegant design Connection base Z-200 or Z-200-H 2 wire connection without polarity With or Without built in isolator 17

Addressable Modules Features Full range DIN rail installation With or without isolator Safe box for modules Connections through removable terminal blocks 18

Addressable call points and sounders Manual call point MAD-450 without isolator MAD-450-I built-in isolator Addressable sounders MAD-464-I sounder & isolator MAD-465-I sounder beacon & isolator MAD-472 sounder base MAD-473 sounder base w/ beacon Maximum sounders per loop: 1Km up to 30 sounders 2Kms up to 15 sounders * Use loop calculator 19

Configuration software (Free) Intuitive and user friendly (Windows) Drag and drop Logical maneuvers programmation Download for free in our website: www.detnov.com/en/new 20

Conventional systems 21

Conventional control panels Full range: 2 up to 12 zones CCD-102 / CCD-104 / CCD-108 / CCD-112 Easy installation (ABS plastic case) 32 devices per zone Differentiation between the MCP and detector alarm Test mode per zone Non polarity Connection into the addressable loop PC programmable 22

Conventional detectors DOD-220: Smoke detector DTD-210: Heat detector DTD-215: High heat detector DOTD-230: Smoke and heat detector Elegant design Connection base Z-200 or Z-200-H Available in color 23

Connection example RELAY OUTPUT ALARM & FAULT EOL R. 4K7 OUTDOOR SOUNDER OUTPUT EOL R. 4K7 EOL R. 4K7 EOL R. 4K7 CONFIGURABLE EXTERNAL INPUT 24V RESETTEABLE OUTPUT 24V AUXILIARY OUTPUT SOUNDERS DELAY 24

Modbus Communication Card Expansion Card TMD-100 RS485 network output Integration with BMS Integration with other security systems Management and control in zone level Communications protocol 100% open 25

Extinguishing control panel 26

Extinguishing system CCD-103 3 detection zones and one extinguishing risk Certified EN12094/1, EN54-2 y EN54-4 One output for the activation of the bottle and one for the warning sign. 2 inputs for the bottle surveillance: pressure and one for the flow Working modes for the extinguishing block: Manual, automatic and y abort. Two sounder outputs for the indication of the extinguishing states.: Pre-activated y activated. Configurable extinguishing delay on board. Two inputs for the area s surveillance: one for the door and one for the fan. Event and configuration history register. Three MCP inputs: start, stop and hold. Optional communication card that allows the integration in an analog loop. Configuration Software. 27

Connection 28

CO detection 29

CO detection panels Expandable up to 3 zones 32 detectors per zone 2 wires without polarity 2 kms cable lenght Working modes: Instantaneous / Media / Intelligent Battery use 24V and 24V Aux 30

Voice evacuation EN54-16 certification for voice evacuation systems 31

Linear smoke detection Motorised barrier DBD-DL40: from 40 to 100 metres* Separated controller and detector Transmitter and receiver in the same case Self configuring and self aligning Avoids false alarms and misalignments caused by vibrations IP65 protection Wet areas Easy maintenance *Expansion sets for 80m and 100m 32

Independent detectors Certificate CPR EN15604:2005 + AC 2008 (domestic use) 10 year battery life Battery and sounder incorporated Self resetting Calypso-II Calypso-II-R ACCTA043 Universal via radio receiver 33

Independent detectors Accessories Connectables for the Calypso-II-R detectors ACC0015 Optical acoustic sounder via radio Iroise TP4+R Manual call point with sounder via radio ACC0014 Pillow vibrator vía radio Nemo +R Manual call point via radio 34

CO Detectors Figaro Electrochemical cell for high accuracy Time response less than 10 seconds 10 years of useful life time Anti vandalism IP65 Standard DMD-500 Compact DMDP-500 35

Smart fan regulation Energy Saving Inverter 1 Fan 1 Scada Software CO Panel Inverter 2 Fan 2 36

New Developments 37

Graphical repetear RS-485 RTD-150T RTD-150E Intuitive Elegant and discreet Graphic management Sending emails Maintenance Security Multiple users HDMI Ethernet RTD-150W RTD-150W 38

Detnov Explorer TED-151WS Customer request for telemantenance & remote control Same card for both systems (conventional & addressable) IP Connection via Ethernet card Web Server Full control remotely On time information Sending e-mail for communication 39

Detnov Cloud TED-151-CL A new concept of fire alarm system Each control panel is connected to the cloud Each customer (installer) manager their installations Tele mantenance & remote control 40

Detnov Cloud - mobile App TED-151-CL Management of critical situations: Real time full information Cost effective solution Secured cloud 41

New Network card 1 Network panel RS-485 port 2 Modbus RS-485 outputs 1 RS-232 serial port 1 Ethernet port Up to 64 network panels 42

New Fire Control panel CAD-250 Touch screen 10 inches for graphical interface Intuitive information Maps and drawings Up to 32 loops and 64 control panel network 43

LPCB product range Complete new detector New design & technology Last generation microprocessor Sensitivity amplifier in the processor High sensitivity detection Multicriterial detector (smoke & heat) Now in LPCB laboratories Sales Estimated Q2 2018 44

New gas detector DGD-600 & 620 Full range of versions: For standalone or addressable solution LPG or City gas 24V or 220V Figaro sensor technology inside Alarm & fault relay outputs Test button Elegant desing for residential & industrial applications 45

Thank you for your Time www.detnov.com Sant Boi De Llobregat Barcelona. Spain. Mob.: 0034 664 658 623 Tel.: 0034 933 716 025 m.elmerouani@detnov.com www.linkedin.com/in/m-merouani 46