Energy. The Energy ducted units have been designed. Heat Recovery Unit

Similar documents
Heating / Air Conditioning Energy Heat Recovery Units ENVIRONMENTAL COMFORT

Helios. Unit Heater. Thickness 1 mm. Diameter 22 mm. Pitch 2,5 mm. Fin 0,12 mm

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Ceiling Air Conditioning Elegant

SkyStar SK. Cassette Fan Coil Unit with Asynchronous Motor

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

SkyStar SK-ECM. Cassette Fan Coil Unit with EC Brushless Electronic Motor and Inverter Board

Comfort. COMFORT Sabiana circular unit heaters, for ceiling installation only,

Carisma Fly. Made in. Italy. Wall-mounted Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT.

NEW. Wall Controls. Air Conditioning Ceiling Air Conditioning Elegant. Cert. n 0545

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS

HEAT RECOVERY UNITS Energy Plus INSTALLATION, USE AND MAINTENANCE MANUAL

Cert. n Air Conditioning Vulcan Pro Air Handling Units

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

AIR DESIGN WATER ITALIA CARISMA COLLECTION

Type PWX HORIZONTAL CHASSIS TYPE WATERSIDE FANCOILS FOR CONCEALED OR EXPOSED INSTALLATIONS

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

with UE 1253/14 Regulation Compliant Air Conditioning Titan Air Handling Units Cert. n 0545

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

REKO heat recovery units REKO HEAT RECOVERY UNITS TYPE A TYPE D

UniTrane Ductable Units D-line and B-Line

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Futura Fan Coil Units ICIM

UniTrane Terminals. High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line Blower coil: B-Line. Product Presentation September 2016

DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

Precision air handling cabinets Ciatronic MICRO/EXPAIR

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

Blower-YEFB-020-3R-1maxVel

The technical and dimensional data reported in this manual may be modified in view of any product improvement.

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

CLIMACIAT AIR COMPACT

GHE Dehumidifiers for radiant cooling systems with heat recovery

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.


290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

NEW GREEN TECHNOLOGY

FAN COIL UNITS. The optimal solution for limited space

COMPACT AIR HANDLING UNIT

ATC Heating Devices. P. 1 ATC Heating Devices

The Sabiana. of Fan Coil

IGH FX / IGH FX EC. Heat Recovery Ventilation Unit

VERSO Air Handling Units

Air Conditioning Carisma CRS High Pressure Fan Coil Units.

VERSO Air Handling Units

NEW. MB control board. communication protocol. for Modbus. Air Conditioning Carisma CRSO High Pressure Fan Coil Units

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION

ART-U 1-4 kw. Design fan coil unit with a minimum depth of 10 cm only and BLDC motor. Fan coil ART-U PLUS. Design-driven innovation NEW

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

Technical Manual. New Water Cassette. Series BREZZA DOUBLE

FHE. Dehumidifiers for radiant cooling systems with heat recovery. Display. Versions

NEXT DL NEXT DL. rcgroupairconditioning

Conditioning your ambient, maximising your comfort.

TECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

CAW Ceiling-mounted fan heaters for hot water

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

FH - GH FH - GH. Dehumidifiers for radiant cooling systems. Versions

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

Компрессорно-конденсаторные агрегаты. Chiller. AQH DCI 20 to 30. Air Cooled Water Inverter Heat Pump Engineering Data Manual. 20 to 30 kw.

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

condenciat cl Condensing units Outdoor condensing unit Variable speed propeller fan Use Description for direct expansion applications

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

consumption ECM motors NEW Low energy Cassette Fan Coil Units YHK ECM YHK

CLIMACIAT AIRTOP. Air handling units. Very short delivery time Double wall with 50 mm insulation. Complete range meeting all the tertiary requirements

Galletti IWC THE HYDRONIC CASSETTE UNIT PAR EXCELLENCE A guide to choosing Create value to design better

APPLICATION GUIDE DUCTABLE FANCOIL ARIA 2. 1,3-6,6 kw ARIA2-AGU-1610-E.

ECOCIAT. Domestic hot water heat recovery unit. Use. Range

pyxis u pyxis ua NEW rcgroupairconditioning

FRAL SRL via dell industria e dell artigianato, 22/C Carmignano di Brenta - PADOVA - ITALY

TopMaster Air Handling unit. Technical data

GHE. Dehumidifiers for radiant cooling systems with heat recovery. Display

IN LINE MIXED FLOW DUCT FANS AND ELECTRIC HEATER TD-MIXVENT HEATING System

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

Remote Air Cooled Condensers C2 Series

SELECTION, INSTALLATION AND MANUTENTION MANUAL HEAT RECOVERY UNITS.

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

Small Room Heat Recovery Ventilation

INDEX. Main components 3. General features and description of the components 4

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

NKW. Heater series HEATERS

Your Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED

Transcription:

Energy Heat Recovery Unit The Energy ducted units have been designed to allow energy savings in the ventilation systems of public and private environments, such as bars, restaurants, offices, shops, etc., by recovering the heat from the air discharged and transferring it to the fresh air introduced into the environment. The heat exchange between the discharged air and the fresh air introduced occurs via a static cross-flow coil, designed to recover over 50 of the heat. The Energy range features 6 sizes suitable for horizontal installation (1 to 6) and 5 sizes for vertical installation (2 to 6), covering a range of air flows from 400 to.500 m /h. In the following pages the horizontal version is shown. 1

Technical characteristics of the main components: Support frame: is made of galvanized plate sandwich panels, 24 mm thick, filled with high-density polyurethane that combine thermal and acoustic insulating features. Size, on the other hand, uses both sandwich panels and self-supporting panels insulated with foam material. The side panels are easily removable, allowing the position of the air inlet and outlet to be modified, even on site. Heat recovery: the heat recovery units are static plate coils that transfer heat between two flows of air due to the temperature difference. Being static, there are no moving parts. This is a guarantee of very high reliability and operating safety. The two flows of hot and cold air entering the heat recovery unit are sub-divided into sections that run between two plates, which carry hot air and cold air alternatively. These sections are sealed to prevent any possible contamination between the air flows. The heat is exchanged by the plates that make up the walls of the sections, with that reaches values between 50 and 75. To increase the efficiency of the coil, the surfaces of the plates are fitted with special swirlers. Condensate collection tray: with drain connection on the side (external dia. 14 mm). Fan assembly: the discharge and intake air fans are double intake with forward blades. The rotor is directly coupled to the electric motor, reducing the overall size. Single-phase motor, 20 V power supply with built-in motor protection, three speeds on all models. Air pleated cell filters, 48 mm thick, efficiency G, with filtering media made from regenerable synthetic material, class F1. The filters can be removed from below after having removed the bottom panel of the unit. Post-Heating coil (optional): built on a special galvanised plate frame, expanded /8 copper pipes, aluminium fins with 2.1 mm fin spacing, brass manifolds. 2

Dimensions and Weight X M C 60 A 80 B 80 K W 150 Z Y Z D H N W Z 85 C C 85 D D C H SIZE 1 2 4 5 6 DIMENSIONS mm A B H C D M N W X Y Z P K 100 1480 1480 1480 1750 1750 80 1000 1000 1000 285 420 480 480 540 540 27 16 16 16 470 470 201 204 264 264 25 25 97 208 208 262 262 290 22 22 22 22 298 1 207 45 45 207 244 244 244 21 21 98 161 161 188 188 202 14 200 27 27 585 585 585 740 740 WEIGHT Kg 41 85 9 105 140 155 NOTE = is only available in horizontal model.

ENERGY TECHNICAL SPECIFICATIONS without Post-heating coil Working static pressure = 50 Pa MODEL ENY High speed Sound pressure ( * ) m /h db(a) 620 54 1200 56 1450 58 2150 62 2500 60 800 64 Medium speed Sound pressure ( * ) m /h db(a) 55 52 940 52 1080 5 1690 58 160 58 2800 60 Low speed Sound pressure ( * ) m /h db(a) 65 49 780 49 840 48 1040 51 1270 48 220 56 HEAT RECOVERY ENY High speed Efficiency (-5 / 20) 54.6 8.6 54.2 8.5 54.5 8.6 51.9 7.9 58.2 9.5 51.1 7.8 Medium speed Efficiency (-5 / 20) 55. 8.8 55.6 8.9 56.4 9.1 5.5 8.4 60.8 10.2 5.5 8.4 Low speed Efficiency (-5 / 20) 57.1 9. 56.6 9.2 58.0 9.5 56.6 9.2 62. 10.6 55. 8.8 ( ) = Sound pressure measured in an open field at a distance of 1 metre from the fan outlet. * NOTE = is only available in horizontal model. with Post-heating coil Operation at high speed Working static pressure = 50 Pa MODEL ENY m /h 580 1080 170 2020 2400 600 HEAT RECOVERY ENY Efficiency (-5 / 20) 54.9 54.8 54.9 52.4 58.4 51.5 8.7 8.7 8.7 8.1 9.6 7.9 POST-HEATING WATER COIL ENY Rows N Emission (air 8 water 70/60) kw 5.92 11.7 15.9 20.4 25.5 4.9 7.1 8.8 41.2 6.8 8.2 5.6 Air side pressure drop (coil) Pa 45 6 28 5 42 64.7 Water side pressure drop kpa 6 7 14 22 19 5,5 Diameter of threaded male connections Ø NOTE = is only available in horizontal model. 4

Accessories CCS Connecting duct for cooling section Made from galvanized steel with closed cell insulation. SB4 Cooling section with 4 row coil (for horizontal units only) SFE Auxiliary electrostatic filter section BCR Condensate tray for cooling section BER Electric post-heating coil (for 6 only) To be installed inside the unit, downstream the recovery unit on the fresh air flow. The coil is provided with an automatic reset safety thermostat and a manual reset safety thermostat. PMR Flanges with spigots The accessory is made of a flange to be coupled to the rectangular inlets and outlets so as to allow the coupling with round ducts. The kit provides no. 4 flanges per unit. 5

Accessories SFR Kit with F6 filters (for -6 only) Special F6 filters in micro-pleated fibreglass. Controls COM Speed switch Remote manual speed control. Switch with 4 positions: - OFF - low speed - medium speed - high speed CIF Speed switch and switch for the electrostatic filter 6

The descriptions and illustrations provided in this publication are not binding: Sabiana reserves the right, whilst maintaining the essential characteristics of the types described and illustrated, to make, at any time, without the requirement to promptly update this piece of literature, any changes that it considers useful for the purpose of improvement or for any other manufacturing or commercial requirements. Sabiana s.p.a. via Piave, 5 20011 Corbetta Milano Italy phone +9.02.9720.1 r.a. / +9.02.97270429 /+9.02.97270576 fax +9.02.9777282 / +9.02.9772820 www.sabiana.it info@sabiana.it EN-LT-EN-07-14 7