SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Ceiling Air Conditioning Elegant
|
|
- Noah Booker
- 5 years ago
- Views:
Transcription
1 Air Conditioning Ceiling Air Conditioning Elegant ISO 00 - Cert. n 0/ Unit heaters Radiant panels Fan coils Air handling units Flues SABIANA ENVIRONMENTAL COMFORT
2 Air Conditioning SABIANA ENVIRONMENTAL COMFORT
3 Introduction The Elegant Sabiana air conditioners allow, at very economical cost, to heat and cool small and medium size environments, like shops, show rooms, workshops, supermarkets. The range is made up of models: models, for heating only and models, for heating and cooling. All models are for ceiling installation and for hot/chilled supply. The air conditioners are supplied with a speed motor. On request motors with integrated electronic circuit are avaible, they allow to control the air from 0 to 0%. The intake of the air is from the bottom side of the unit and the air supply is from the lateral grids which have individually controllable louvres for the best distribution of the air. The connection to the battery can be made either from the upper or from the lateral side, in accordance to the installation with or without false ceiling. The condensate drain is made through an electronically controlled micro-pump, supplied on every standard model. Different remote controls of the air and of the room temperature are available and it is possible to control up to units with only remote control. Beside the low installation and running cost, the Elegant air conditioners offer the following advantages: they take a low amount of the valuable space in the room, there is not any ducting system and the walls are free. they are versatile and provide flexibility of installation: also where there is no false ceiling it is possible to distribute the air evenly. they provide easy control and are easily installed.
4 CASING The casing is made of steel on both top and bottom sections and it is designed to give greater strength and quieter operation. The casing is then phosphatised and finished with an epoxy-polyester powder coating dried at 0, in white RAL 0. The lower casing is also the condensate collection tray. The casing is fitted with galvanized steel screws and so it is possible to quickly dismantle it for inspection when needed. OUTLET GRIDS The discharge of the air is obtained through grids on the lateral sides. The grids are made of steel, painted with epoxy-polyester powder. They are made by a frame in which the louvres are individually adjustable. It is very easy to take off these grids, allowing for easy maintenance of the battery and of the condensate tray. ELECTRIC MOTOR Standard motors are with closed frame, IP protection, F class isolation, speeds, for 0V-PH-0HZ supply. The motor is fitted on its support by the means of anti-vibrating mounting. HELICOIDAL FAN The fan is with aluminium blades statically and dynamically balanced. Its rational high-capacity profile provides the maximum air volume with the minimum energy consumption. The fan hub is secured onto the motor shaft and it is protected by a finger proof guard. HEAT EXCHANGER The heat exchanger of the Elegant SABIANA has a circular shape and is constructed of copper tubes with aluminium fins and steel headers. The supply and return connections have a female threading, diameter, and they allow the connection either vertically from above or horizontally from a side. The battery is supplied in two versions: with row and with rows. The heat exchanger is not suitable for use in corrosive atmosphere or in environments where aluminium may be subject to corrosion. PACKAGING Every Elegant air conditioner is supplied in a robust cardboard box with the relevant installation and maintenance manual. CONDENSATE MICRO-PUMP The model for cooling is always supplied with an integral micropump (discharge head m, ). The pump is installed in the condensate collected tray. This pump controls the level of the condensate collected in the tray and eliminate it when necessary. To prevent the pump from blocking and malfunctions in the condensate detection system, check that there are no significant quantities of oil in suspension and/or dust in the room being treated.
5 Installation Installation without false ceiling Installation with false ceiling Model only heating Model heating and cooling WARNING In cooling systems - always install the unit with a small inclination towards the hydraulic connections side, in order to allow a good suction of the condensate micro-pump. - you are recommended to shut off the supply to the coil using the /-way valves, electrically connected to the control with thermostat, to avoid condensation forming on the outside of the unit.
6 Dimension, weight, content ROW BATTERY (only heating) Dimension mm Dimension mm Weight Kg content l ROW BATTERY (heating and cooling) Female Weight Kg content l
7 Main technical figures MOD. Emission speed speed Heating speed Total emission Tot. Sens. Tot. Sens. Tot. Sens. Tot. Sens. Tot. Sens. speed speed Cooling Air speed speed m /h speed m /h speed m /h Noise pressure level at m. speed speed speed db(a) db(a) db(a) Electric motor IP 0V - Ph 0Hz W A μf.... Maximun working pressure: bar HEATING COOLING Battery test pressure: bar Air temperature: +0 C temperature: 0/0 C Air temperature: + C d.b./ + C w.b./ % R.H. temperature: / C speed speed Maximum Height m. Surface R=m Maximum Height m. Surface R=m
8 row battery, heating emission ( model) Entering air temperature + 0 C temperature C temperature C temperature C Mod. Speed Air m /h E.W.T. 0 L.W.T. 0 Emission L.A.T. E.W.T. 0 L.W.T. 0 Emission L.A.T. E.W.T. L.W.T. Emission L.A.T. C C C Entering air temperature C temperature C 0/0 0/0 / Correction factors for different conditions
9 row battery, heating emission ( model) Entering air temperature + 0 C temperature C temperature C temperature C Mod. Speed Air m /h E.W.T. 0 L.W.T. 0 Emission L.A.T. E.W.T. 0 L.W.T. 0 Emission L.A.T. E.W.T. L.W.T. Emission L.A.T. C C C Enteringair temperature C temperature C 0/0 0/0 / Correction factors for different conditions
10 Cooling emission ( model) Entering air temperature + C; relative humidity % Mod. Speed Air m /h Emission L.A.T. Total Sensible C temperature / C Emission L.A.T. Total Sensible C temperature / C temperature / C temperature / C A sensible heat figure higher than a total heat figure shows that the cooling is obtained without dehumidification, therefore the emission to refer to is the sensible one.
11 Cooling emission ( model) Entering air temperature + C; relative humidity % Mod. Speed Air m /h Elission L.A.T. Total Sensible C temperature / C Elission L.A.T. Total Sensible C temperature / C temperature / C temperature / C A sensible heat figure higher than a total heat figure shows that the cooling is obtained without dehumidification, therefore the emission to refer to is the sensible one.
12 Cooling emission ( model) Entering air temperature + C; relative humidity % Mod. Speed Air m /h Emission L.A.T. Total Sensible C temperature / C Emission L.A.T. Total Sensible C temperature / C temperature / C temperature / C A sensible heat figure higher than a total heat figure shows that the cooling is obtained without dehumidification, therefore the emission to refer to is the sensible one.
13 Cooling emission ( model) Entering air temperature + C; relative humidity % Mod. Speed Air m /h Emission L.A.T. Total Sensible C temperature / C Emission L.A.T. Total Sensible C temperature / C temperature / C temperature / C A sensible heat figure higher than a total heat figure shows that the cooling is obtained without dehumidification, therefore the emission to refer to is the sensible one.
14 Electronic controls and electric wirings TMO-T electronic room thermostat - ON-OFF switch. - speed switch. - Manual or remote Winter/Summer switch. - Room thermostat. TMO-T Code 00 0 C Respect the electric wirings below ( model with TMO-T) The thermostat controls the fan, ON-OFF. The thermostat controls the valve. The fan runs continuously at the selected speed. Respect the electric wirings below ( model with TMO-T) The thermostat controls the valve. The fan runs continuously at the selected speed. Model - - A Grey Green Green B C Orange Orange D Arancio
15 Slave speed switch Up to units can be controlled by one central control, model TMO-T (code 00). Speed switch Code 0 On each unit the slave speed switch (code 0) must be fitted on board. Wiring diagram (Slave with TMO-T) Mod. - - A Grey Green Green B C Orange Orange D Orange - E F G MFC US CM EL Blue Brown Yellow / Green Fan-Coil Terminal Board Safety switch Condensate Micro-pump valve speed switch MO-V remote manual speed switch - ON-OFF switch. - speed switch. MO-V Code 00 Electric wiring ( with MO-V) Model - - A Grey Green Green B C Orange Orange D Arancio
16 Electric wiring with TMO-DI Automatic Identification Version electronic thermostat TMO-DI NON FITTED To be installed on the wall TMO - DI FITTED or in the electric switch box. - Manual or automatic speed switch. - Manual or automatic Summer/Winter switch. - Electronic thermostat for fan control (ON-OFF). - Electronic thermostat for valve(s) control (ON-OFF). - Simultaneus thermostatic control of the valves and fan (ON-OFF). - It allows to control the low temperature cut-out thermostat TME. - It allows to control the chilled valve (ON-OFF). - It allows to control up to units with SEL-DI speed switch. Code 00 0 Electric wiring of slave switches for TMO-DI Identification Version Code SEL - DI NON FITTED FITTED 00 0 Attention: for TMO-DI must be used the repeater for TMO-DI code 00 only. Model - - A B C D Grey Orange Green Orange Green Orange E F G MFC CM E Dark Blue Brown Yellow / Green Fan-coil terminal board Condensate micropump Electro-valve
17 Accessories Fan motor with 0/0% speed control On demand, a special motor is available for the progressive control of the fan speed from 0 to 0% in order to obtain the desired performance. Condensate alarm sensor This alarm sensor has to be installed by the mechanical engeneer and it stops the supply in case the micro-pump is not working. The sensor has to be fitted at the internal vertical part of the lower casing, close to the connections and at mm. from the bottom. In case of need the control stops the fan and the valve and the alarm led is switched on. The use of the valve is suggested in order to stop the supply.
18 Accessories way valve + connection kit Composed by: - one -way valve / KVS, - one actuator - pipe connections Hanging brackets Composed by eye bolts and screws Washer for screw M Screw M x Eye bolt female M Cover panel To be fitted on the fan guard The descriptions and illustrations provided in this publication are not binding: we reserve the right, whilst maintaining the essential characteristics of the types described and illustrated, to make, at any time, without the requirement to promptly update this piece of literature, any changes that it considers useful for the purpose of improvement or for any other manufacturing or commercial requirements.
19
20 Air Conditioning Ceiling Air Conditioning Elegant EL - EX - 0/0 COD. A0 C/0/0 SABIANA ENVIRONMENTAL COMFORT Sabiana s.p.a. via Piave, 00 Corbetta Milano Italy phone r.a. / / fax +.0. / info@sabiana.it
NEW. Wall Controls. Air Conditioning Ceiling Air Conditioning Elegant. Cert. n 0545
NEW Wall Controls Cert. n 0545 Air Conditioning Ceiling Air Conditioning Elegant CONTENTS Page Introduction 3 Main components 4 Dimension, Weight, Water content 5 Main technical figures 6 Working conditions
More informationCarisma Fly. Made in. Italy. Wall-mounted Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT.
Made in Italy Air Conditioning Wall-mounted Fan Coil QUALITY MANAGEMENT SYSTEMS ISO 9001 - Cert. n 0545/5 www.eurovent-certification.com www.certiflash.com ENVIRONMENTAL COMFORT CONTENTS Introduction Version
More informationSABIANA ENVIRONMENTAL COMFORT. Air Conditioning Futura Fan Coil Units ICIM
Air Conditioning Fan Coil Units ICIM ISO 900 - Cert. n 0545/2 Unit heaters Radiant panels Fan coils Air handling units Flues SABIANA ENVIRONMENTAL COMFORT Sabiana is the fan coil that continues the Sabiana
More informationSkyStar SK. Cassette Fan Coil Unit with Asynchronous Motor
SkyStar SK Cassette Fan Coil Unit with Asynchronous Motor Innovating and beautiful design, seven different sizes, high control flexibility, easy maintenance: the SkyStar chilled water Cassette is the result
More informationProduct is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue
cert. n. 0545 Product is subject to and complies with Regulation (UE) N.327/2011 Fan Coil Unit Cassette SkyStar Jumbo ECM technical catalogue SkyStar Jumbo ECM Table of contents SkyStar Jumbo ECM TABLE
More informationEnergy. The Energy ducted units have been designed. Heat Recovery Unit
Energy Heat Recovery Unit The Energy ducted units have been designed to allow energy savings in the ventilation systems of public and private environments, such as bars, restaurants, offices, shops, etc.,
More informationSkyStar SK-ECM. Cassette Fan Coil Unit with EC Brushless Electronic Motor and Inverter Board
SkyStar SK-ECM Cassette Fan Coil Unit with EC Brushless Electronic Motor and Inverter Board The SkyStar SK-ECM series, available in 5 models, uses an innovative brushless synchronous permanent magnet electronic
More informationCarisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT
Made in Italy Air Conditioning High Wall Fan Coil -ECM QUALITY MANAGEMENT SYSTEMS ISO 9001 - Cert. n 0545/5 www.eurovent-certification.com www.certiflash.com ENVIRONMENTAL COMFORT CONTENTS Introduction
More informationHeating / Air Conditioning Energy Heat Recovery Units ENVIRONMENTAL COMFORT
Heating / Air Conditioning Energy Heat Recovery Units ISO 9001 - Cert. n 0545/4 Unit heaters Radiant panels Fan coils Air handling units Flues ENVIRONENTAL COFORT Heating Air Conditioning ENVIRONENTAL
More informationComfort. COMFORT Sabiana circular unit heaters, for ceiling installation only,
Cofort Circular Unit Heater COMFORT Sabiana circular unit heaters, for ceiling installation only, are especially suitable for high roos, even if the optiu ratio between the air flow-rate and the heat output
More informationHelios. Unit Heater. Thickness 1 mm. Diameter 22 mm. Pitch 2,5 mm. Fin 0,12 mm
Thickness 1 mm Diameter 22 mm Pitch 2, mm Helios Unit Heater Fin 0,12 mm The HELIOS Sabiana unit heaters, built with the same criteria of sturdiness and safety that define all Sabiana products, stand out
More informationHigh wall fan coils Climmy FHW/FHW-ECM. Technical Catalogue
High wall fan coils Climmy FHW/FHW-ECM Technical Catalogue Versions and Main components MODELS WITHOUT ELECTRIC HEATER All versions are available without valves, with 2 way valve or with 3 way valve fitted
More informationNEW. MB control board. communication protocol. for Modbus. Air Conditioning Carisma CRSO High Pressure Fan Coil Units
NEW MB control board for Modbus communication protocol Compliant with ERP 0 Regulation (EU) No. 7/0 Quality management systems ISO 900 Cert. n 0/ www.eurovent-certification.com www.certiflash.com Air Conditioning
More informationTECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT
1. GENERAL INFORMATION 1.1 Applications page 2 1.2 Operation» 2 1.3 Performances» 2 1.4 Product range» 2 1.5 Selection software» 2 2. DIMENSIONS AND WEIGHTS» 3 3. COMPONENTS 3.1 Structure» 4 3.2 Coils»
More informationAir Conditioning Carisma CRS High Pressure Fan Coil Units.
Air Conditioning Carisma CRS High Pressure Fan Coil Units Quality management systems ISO 900 Cert. n 0/ www.euroventcertification.com www.certiflash.com INTRODUCTION In line with innovative trends and
More informationNEW. SkyStar SkyStar ECM. Cassette Fan Coil Units. consumption ECM motors. Low energy. Air Conditioning ENVIRONMENTAL COMFORT
NEW energy consumption ECM motors Air Conditioning ECM Cassette Fan Coil Units ISO 9001 - Cert. n 0545/4 Unit heaters Radiant panels Fan coils Air handling units Flues ENVIRONMENTAL COMFORT CONTENTS Introduction
More informationconsumption ECM motors NEW Low energy Cassette Fan Coil Units YHK ECM YHK
NEW energy consumption ECM motors ECM Cassette Fan Coil Units www.eurovent-certification.com www.certiflash.com CONTENTS Introduction Page 3 Main components Page 4 EUROVENT Certifications Page 5 Emissions
More informationThe Sabiana. of Fan Coil
The Sabiana family of Fan Coil Range Basics A complete range of fan coils for use with Hot water for heating and chilled water for cooling Eurovent Certified Typical Applications Schools Hotels Commercial
More informationTHIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM
THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM 0,7 kw 5,2 kw 1,6 kw 10,2 kw 130 m 3 /h 830 m 3 /h SLIM SLIMxx0 vertical with cabinet bottom vertical Available also with feet SLIMxx8 SLIMxx5 SLIMxx4 SLIMxx9
More informationDUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS
EN DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS EBH EDS EBH EDS HIGH PRESSURE UNITS EBH high pressure ducted units and EDS Double Skin units, thanks to their high pressure fan decks, permit to satisfy
More informationDUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX
Duct unit DUCTIMAX Medium available static pressure ducted hydronic units DUCTIMAX - 8 kw NEW PRODUCT JUNE 05 Performance and compactness in recessed ceiling installations ERGO Supervision Plus -pipe system
More informationBlower-YEFB-020-3R-1maxVel
YEFB DUCTED UNIT GENERAL FEATURES Structure It is made of 1,0 mm thick galvanised steel. Despite this thickness, a special tool for production allowed to keep a good stiffness, in order to reduce the risk
More informationWATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED
EQV R-407C WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED Size Cooling Heating [kw] [kw] 5 1,9 2,2 7 2,4 2,5 9 2,6 2,5 15 3,3 3,2 17 3,7 3,7 REPLACE: BT02E008GB-01 The Versatemp EQV units
More informationBRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01
b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a
More informationWATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ
WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ SERIES: EWCBZ - Heat pump MODELS: 70, 80, 00, 0, 60, 00, 40, 00, 50 COOLING CAPACITIES from 5,9 kw to 78,5
More informationNEW. communication protocol. Control board with Modbus. Air Conditioning SkyStar SkyStar ECM Cassette Fan Coil Units
NEW Control board with Modbus communication protocol Air Conditioning ECM Cassette Fan Coil Units Quality management systems ISO 9001 Cert. n 0545/5 www.eurovent-certification.com www.certiflash.com MD-600
More informationSIGMA PRISMA LOW BODY CONCEALED
EN SIGMA PRISMA LOW BODY CONCEALED EST EST (Energy Saving Technology) is applied to the EURAPO fan coil units and cassette units. It permits to obtain extremely low electrical absorption and a continuous
More informationDERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E
DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E INTRODUCTION DERV/ERV Introduction Dehumidification & Energy Recovery Ventilator DERV units
More informationKälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10
Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW Compressors Scroll Serie: Series: Emissione: Issue: SCAEY Catalogo: Leaflet: Sostituisce: Supersedes: DE 88 04/11 12/10 Index
More informationFAN COIL UNITS LASER / LOW BODY / CONCEALED
SAPHIR TECHNICAL LITERATURE FAN COIL UNITS LASER / LOW BODY / CONCEALED Energy Saving Technology EST (Energy Saving Technology) is applied to the Johnson Controls fan coil units and cassette units. It
More informationCWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling
TECHNICAL INSTRUCTIONS CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT Cooling Heating CWX 3 pipes.60 3.9 pipes + electric heating.08.96 +.5 pipes.08.5 CWX 5 pipes.70 5.70 pipes + electric heating.3 5.3 +.50
More informationNEW GREEN TECHNOLOGY
NEW GREEN TECHNOLOGY - suitable for all heating systems Magnetic Boiler installed in all fan coils - no need for external devices! A c t i v e G r e e n S w e d e n A B ACTI VE Operation limits This technology
More informationNew Industrial Dual Flow Unit Coolers
New Industrial Dual Flow Unit Coolers One single smart platform offering a wide range of solutions 01 Applications Thanks to a considerable air flow and an optimal air distribution, the new Dual Flow Units
More informationFH - GH FH - GH. Dehumidifiers for radiant cooling systems. Versions
Dehumidifiers for radiant cooling systems FH GH 138 The dehumidifiers FH and GH series are high performance units, equipped with robust galvanised steel frame, properly designed to operate in combination
More informationtechnical data Fan coil unit FWB small duct unit
technical data Fan coil unit FWB small duct unit TABLE OF CONTENTS FWB 1. Nomenclature ---------------------------------------------------------------------- 2 2. Features -----------------------------------------------------------------------------
More informationAll side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.
All outdoor units are designed to perform satisfactorily at 52 C, with the option of either top discharge condensing units, with Copeland reciprocating scroll compressors. All top discharge condensing
More informationUniTrane Terminals. High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line Blower coil: B-Line. Product Presentation September 2016
UniTrane Terminals High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line Blower coil: B-Line Product Presentation September 2016 Agenda Product overview Key features Product range Controls Emissions Accessories
More informationAIR DESIGN WATER ITALIA CARISMA COLLECTION
AIR DESIGN CARISMA COLLECTION ITALIA WATER The air that you breathe is pure Design Maybe you are looking for an air-conditioner. In truth you are looking for beauty. This is why the Carisma Fan Coil Units
More informationAir cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw
Air cooled chillers with brushless oil-free compressors R-134a RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw External installation with very low sound level Cooling circuit with
More informationWATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP
EVH R-407C WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP Size Cooling Heating [kw] [kw] 7 2.0 1.9 11 2.6 2.5 15 3.9 3.3 5.2 5.5 25 7.3 6.7 31 8.9 8.4 41 10.7 9.8 REPLACE: BT02E009GB-01 The Versatemp
More informationCOOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw
COOLROW Close control air conditioners for In-Row installation Cooling Capacity: 14 61 Available in versions equipped with: - BLDC inverter scroll compressor on board of the unit - Chilled water feeding
More informationFHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions
Dehumidifiers for radiant cooling systems with heat recovery 50 The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area
More informationQTS SELECTION TECHNICAL BOOKLET
EN QTS SELECTION TECHNICAL BOOKLET Bi2 FAN RADIATORS AND FAN COILS Italian company established in 1956 2 Bi2 Bi2 TABLE OF CONTENTS 1 Range of system terminals... 6 1.1 Cabinet system terminals... 6 1.2
More informationAIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES
AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES COOLING CAPACITY FROM 76 TO 612 Kw 1 AND 2 COOLING CIRCUITS RAE 1702 F Kc + P2 28 Above picture is only indicative
More informationMHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH
MHNCCW-04-01 (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled and Hot Water Fan Coil 4-Pipe Nominal Size: 12,000
More informationSELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)
SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER) SERIES: WCHZ MODELS: 201, 251, 271, 351, 401, 501, 701, 721, 751 COOLING CAPACITIES OF: 6,4
More informationGHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES
Dehumidifiers for radiant cooling systems with heat recovery The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area
More informationApplication guide. ARMONIA ARMONIA EC 1,3-11 kw. Chilled water cassette Chilled water cassette - EC motor ARMONIA-AGU-1010-E
Application guide ARMONIA ARMONIA EC 1,3-11 kw Chilled water cassette Chilled water cassette - EC motor ARMONIA-AGU-1010-E TABLE OF CONTENTS APPLICATION GUIDE Ref : ARMONIA-AGU-1010-E ARMONIA Introduction
More informationNext P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB
Next P 6 112 kw COOLING 5 93 kw HEATING Heat pump air conditioners with upflow air delivery technicalcatalogue T_NXTP_0411_GB INDEX GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 4 MODEL IDENTIFICATION...
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02
More informationMHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH
MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -
More informationMHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH
MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH
More informationTransformer oil coolers BETA & CETA
2012.1 Transformer oil coolers BETA & CETA Transformer oil coolers BETA & CETA Luvata is pleased to present to the market its renewed transformer oil coolers. The BETA and CETA series of transformer oil
More informationRAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS
AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS RAH 602 Ka + CF + GP 62 Above picture is only indicative and is not binding.
More informationCOMFORT APPLICATION HYDRONIC TERMINALS ELEGANCE AND DESIGN FOR YOUR RESIDENTIAL COMFORT
COMFORT APPLICATION HYDRONIC TERMINALS ELEGANCE AND DESIGN FOR YOUR RESIDENTIAL COMFORT climaveneta.com COMFORT APPLICATION HYDRONIC TERMINALS between elegance, comfort and energy savings Conceived to
More informationCOMPACT AIR HANDLING UNIT
COMFORT AIR HANDLING UNITS COMPACT AIR HANDLING UNIT climaveneta.com COMFORT AIR HANDLING UNITS AIR TREATMENT ENHANCING QUALITY OF LIFE. Compact air handling unit for indoor and outdoor installation. Air
More informationVMA-VMB NOVA AIR HEATERS. NoVa air heaters
VMA-VMB NOVA AIR HEATERS NoVa air heaters PRODUCT FACTS PRODUCT The Novenco NoVa air heaters are water-based units with hot-water heating coils and axial flow fans fitted in cabinets. VMA for 10-20 C cooling
More informationTechnical Data Ducted Three Phase Split System Air Conditioner
ENERGY EFFICIENT ISD / OSA 2 Technical Data Ducted Three Phase Split System Air Conditioner EXTRA LONG LIFE EPOXY COATED OUTDOOR COIL Nominal Cooling Capacity 26.5 kw (Total) JUNE 4 ISD / OSA 2 DUCTED
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING
More informationHigh Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)
High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year
More informationVA G 052 S
763.576.3200 SPEC-00746 D763.422.2211 COOLING SEALED ENCLOSURE COOLING AIR CONDITIONERS Sealed Enclosure Cooling Air Conditioners V-SERIES COMPACT AIR CONDITIONERS VA06 Indoor Model 400 and 600 Watts INDUSTRY
More informationMAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.
MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient
More informationMAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.
MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient
More informationRAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR
AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 46 Above picture is only indicative and is not binding AIR FC The packaged air cooled chillers of RAS Kp series are suitable
More informationREKO heat recovery units REKO HEAT RECOVERY UNITS TYPE A TYPE D
REKO HEAT RECOVERY UNITS The heat recovery units making up the series REKO have been designed and built to solve the problems tied to the high energy consumption of systems that use outdoor air. A high-efficiency
More informationCLIMA CANAL HYBRID CLIMA CANAL. Low Water Temperature system LOW TEMPERATURE SYSTEM / HEATING AND COOLING LOW TEMPERATURE SYSTEM / HEATING
Low Water Temperature system CLIMA CANAL HYBRID: Build-in height of 3.94 > 5.71 CLIMA CANAL: Build-in height of 3.35 > 5.43 fan speed modulation via 0-10V signal CLIMA CANAL HYBRID LOW TEMPERATURE SYSTEM
More informationSLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual
u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications
More informationVA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners
V-Series Mid-Size Air Conditioners (Now done by MGDC) VA08 Indoor Model 1200, 1500 and 2000 Watts INDUSTRY STANDARDS IP 56 Internal Air Loop IP 34 External Air Loop APPLICATION Industrial drive enclosures
More informationMAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.
MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.2 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient
More informationAIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS
RAE 1402 C O K AIR R-407C Series RAE... C K Cooling capacity from 81 to 250 kw - 2 circuits The air cooled chillers of RAE C K series, with centrifugal fans, are designed for indoor installation and are
More informationMAC-120HE-03 Air-Cooled Chiller
MAC-120HE-03 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 380/415/460-3-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-03
More informationEHH SERIES DRAW THROUGH FAN COILS CFM
EHH SERIES DRAW THROUGH FAN COILS 400-5000 CFM TABLE OF CONTENTS TABLE OF CONTENTS 2 INTRODUCTION 3 GUIDE SPECIFICATIONS 4 UNIT OVERVIEW 6 TECHNICAL DATA 8 DIMENSIONS 10 COMPUTER SELECTION 11 GEMCOOL PROFILE
More informationSPECIFICATIONS CWC - 2P / 4P CWC 020 CWC 030 CWC 040 CWC 050 CWC 070 CWC
APPLICATION GUIDE CHILLED WATER CASSETTE CWC - P/4P English/03-005 INDEX Index AGU CWC-P/4P General Description Specifications Performances tables Sound levels Options Dimensions Unit installation Electrical
More informationGHE Dehumidifiers for radiant cooling systems with heat recovery
Dehumidifiers for radiant cooling systems with heat recovery The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area
More informationConditioning your ambient, maximising your comfort.
Centrifugal fancoils for surface mounting or recessed installation. Cooling capacity from 0,6 to 7,6 kw and heating capacity from 0,8 to 9 kw. Air flow from 100 to 1500 m3/h. Cassette with radial fan.
More informationTechnical Data ISU Series. Underceiling/Console Split System Air Conditioners kw 15 kw
Underceiling/Console Split System Air Conditioners Technical Data ISU Series Featuring SAT- Controller & Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 13. kw 15 kw NOVEMBER 0 ISU SERIES
More informationCDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.
DEHUMIDIFICATION 9 CDS 80 FUNCTION The CDS 80 works in accordance with the condensation principle. A fan draws the humid air into the dehumidifier and through an evaporator coil. When passing through the
More informationLOW STATIC HYDRONIC DUCTED UNIT
LOW STATIC HYDRONIC DUCTED UNIT PDWA-~AC SERIES PDWA(4R)-~-V-MEDC PDWA(4R)-~-V-MEEU PDWA(R)-~-V PDWA(R+1)-~-P Model cooling capacity( KW) at Medium Speed cooling capacity (KW) at Medium Speed cooling capacity
More informationTopVent Design Handbook
TopVent Design Handbook Recirculation Units and Supply Air Units for Heating and Cooling High Spaces TopVent Content TopVent DHV Recirculation unit for heating high spaces TopVent NHV Recirculation unit
More informationAerslim Fancoil unit. Technical information manual. Western Airconditioning B.V. Tel. +31 (0)
Aerslim Fancoil unit Technical information manual Western Airconditioning B.V. Tel. +31 (0) 33 247 78 00 www.western.nl INDEX 1-INTRODUCTION... 2 2-OPERATING RANGE... 2 3-RADIANT PLATE... 2 4-CODE COMPORISION
More informationVA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners
763.576.3200 SPEC-00747 D763.422.2211 COOLING SEALED ENCLOSURE COOLING AIR CONDITIONERS Sealed Enclosure Cooling Air Conditioners V-SERIES MID-SIZE AIR CONDITIONERS VA08 Indoor Model 1200, 1500 and 2000
More informationApplication guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort
Application guide FLATAIR - FLCK/FLHK Providing indoor climate comfort MSL60E-0701 12-2006 Congratulations you have made a wise choice and we feel sure that it will meet your expectation INDEX CONTENTS
More informationFAN COIL UNITS. The optimal solution for limited space
FAN COIL UNITS The optimal solution for limited space CLEAN AIR SINCE 1963 Euroclima is a company with extensive international operations with four manufacturing facilities in Italy, Austria and India
More informationCASSETTE UNIT. Comfort Circle
CASSETTE UNIT Comfort Circle Comfort Circle cassette unit All-round comfort With today's energy prices, building owners are increasingly aware of the need for an efficient climate system to heat or cool
More informationCondensing Units CUS 15-60
Condensing Units CUS 15-60 General Description UNIT IDENTIFICATION AIR COOLED CONDENSING UNIT CUS... Condensing Unit with Propeller Fan and Scroll Compressor 15-60... Model Size D... Double Circuit e.g....
More informationGHE. Dehumidifiers for radiant cooling systems with heat recovery. Display
GHE Dehumidifiers for radiant cooling systems with heat recovery Display The dehumidifiers with heat recovery of high efficiency series GHE were designed to provide dehumidification and fresh air in a
More informationTopVent. Recirculation Units and Supply Air Units for Heating and Cooling High Spaces.
TopVent. Recirculation Units and Supply Air Units for Heating and Cooling High Spaces. Safety A 3 TopVent DHV B Recirculation unit for heating high spaces 7 TopVent DKV C Recirculation unit for heating
More informationBRIZA EC 12 HYBRID. Low Water-Temperature system LOW TEMPERATURE SYSTEM / HEATING AND COOLING
Low Water-Temperature system wall and ceiling mounting 2-or 4-Pipe system heating and /or cooling with or without casing easy installation EC motor silent, powerful, economical, sustainable 2-PIPE 4-PIPE
More informationFRAL SRL via dell industria e dell artigianato, 22/C Carmignano di Brenta - PADOVA - ITALY
FRAL SRL via dell industria e dell artigianato, 22/C - 35010 Carmignano di Brenta - PADOVA - ITALY TELPHONE: +39 049 9455839 FAX: +39 049 5991129 E-MAIL: info@fral.it WEB: www.fral.it DEHUMIDIFIERS FD
More informationEvaporators 60HZ version
Innovative Engineering Catalogue Evaporators 60HZ version Heat Exchangers Application areas Freezer rooms Cold rooms Packaging rooms Processing rooms Humidity controled cold rooms Air conditioning Refrigerated
More informationELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems
Technical Bulletin BT13F002GB-04 ELFODuct MP New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems ELFODUCT MP 15-71 SERIES SERIES RECOMMENDED FOR
More informationECM Technology. Technology. Features. Advantages (compared to traditional brushed motors) Power consumption: YFCN versus YFCN-ECM (W/kW)
york air-conditioning products ECM Technology Running costs. Energy consumption. Life cycle. These are 3 issues that are becoming more and more important in the choice of Fan Coil Units. With these criteria
More informationTechnical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil
Ducted Three Phase Packaged Air Conditioner Technical Data, 0, 180 Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 10.0 kw 18.5 kw JUNE 5 , 0, 180 DUCTED PACKAGED ROOF TOP AIR CONDITIONERS
More informationGPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1
UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS GPE 802 Kc + CF + GP + MV + P1 130 Above picture is only indicative and is not binding. AIR R-410A
More informationCATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42
SELF CONTAINED HORIZONTAL UNITS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER ) HEAT PUMP. WCHBZ COOLING ONLY. WCHZ SERIES: WCHBZ - Heat Pump MODELS: 201, 251, 271, 351, 401, 501 COOLING
More informationCONDENCIAT CD. Condensing units. Quiet operation Low speed fans All year round operation USE. Cooling capacity : 25 to 165 kw.
Quiet operation Low speed fans All year round operation Cooling capacity : 25 to 165 kw Cooling only USE The offers a solution to both heating and cooling applications encountered in the public, tertiary
More informationFH - GH Dehumidifiers for radiant cooling systems
Dehumidifiers for radiant cooling systems FH GH The dehumidifiers FH and GH series are high performance units, equipped with robust galvanised steel frame, properly designed to operate in combination with
More informationTechnical Manual. New Water Cassette. Series BREZZA DOUBLE
Technical Manual New Water Cassette Series BREZZA DOUBLE AERTESI srl Cassetta BREZZA DOUBLE Tecnical manual AER.MT.I.BREDOPPIA.000.02.15 Pag.2 INDEX 1-INTRODUCTION 4 2- WORKING CONDITION LIMITS..4 3- COANDA
More informationSMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB
T_SMT_0609_GB 4,9 49,5 kw Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans INDEX SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3 CE CONFORMITY... 3 WORKING
More information