Issued to: Videl S.r.l. Località Ponti di Pievescola Casole d Elsa (SI)

Similar documents
AS/NZS IEC 62560:2014

What You Need to Know About UL rd Edition

AS/NZS 62560:2017. Self-ballasted LED-lamps for general lighting services by voltage 50 V Safety specifications AS/NZS 62560:2017

Australian Standard. Degrees of protection provided by enclosures (IP Code) AS IEC Ed 2.1:2001 AS 60529

SOUTH AFRICAN NATIONAL STANDARD

TEST REPORT Reliability Laboratory Report No.: HCD0203/2008

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

CERTIFICATE of QUALITY TEST

EXNBG CLARIFICATION/DECISION SHEETS NOTED BY THE ATEX STANDING COMMITTEE STATUS ON DECEMBER 2009

TEST REPORT Report No.: HN80013/2011 Page: 1 of 7 Date: August 30, 2011

Initial Test Typing Leak test

AS/NZS IEC :2013

275HVD NON-CONTACT, HIGH VOLTAGE DETECTOR DETECTOR DE ALTA TENSIÓN SIN CONTACTO

Draft for Comment Please comments to Part A(i)

Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming)

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

DRYTEK 1 - User Manual ELECTRICAL PANEL FOR 1 MOTOR WITH POWER FACTOR CONTROL

MARINE GYRO COMPASS STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

This document is a preview generated by EVS

TEST REPORT IEC60529 Edition TD990426C02

ISO INTERNATIONAL STANDARD. Oscillation-type density meters Part 1: Laboratory instruments

Test Report. Appliance EMF Testing

Additional deviations may possibly be found if a complete type test is carried out on the product.

SAR Technical Requirement

Preface. This guide proposes a procedure for assembling the Prisma Plus System G.

Equipment specifications (D6)

Test procedure/ method name. method identification. Testing of industrial and explosion isolation valves and tank lining

Verification & Testing for Conformity Assessment / EC Verification. NB-Rail (ERTMS Group)

Hazardous Area Zirconia Oxygen Systems

AUGUST 2016 CONTENTS:

Environment Test Report

WASTEWATER Online UV%Transmission Analyzer

EN 60529:1991+A1:2000+A2:2013 Measurement and Test Report

COMITÉ EUROPÉEN DES ASSURANCES

RADAR REFLECTOR STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

AS/NZS :2014

Guidance from the Group of Notified Bodies for the Construction Products Directive 89/106/EEC

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

QA16 Addressable Panel Programming Manual V3.07.3

VS LD series vertical steam sterilizers

Lighting Measurement Solutions

ENVIRONMENTAL TEST REPORT

EU RO Mutual Recognition Technical Requirements

INTERNATIONAL STANDARD NORME INTERNATIONALE

Arrow Instruments Calibration

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

AS/NZS :2008

Report No 288/ Part 1 of 2 This report consists of 22 pages. Maxitone ZAMT Type A Addressable Sounder. See Assessment Summary for details

AS/NZS :2003 Luminaires - Part 1: General requirements and tests

PQS Independent type-testing protocol

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Ultrasonic Clamp-On Flow Meter Testing

Kälte Klima. Water cooled water chillers from 200 kw to 1550 kw. Screw Compressor LCWX DE 56 01/16 12/13

Test Report. Shenzhen Longsin Intelligence Technology Co.Ltd.

LOVAG TEST INSTRUCTION IEC/EN

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

PQS performance specification

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

VDE-QT-PV001:2012/01

10057 S. Ambrogio Di Torino. Piacentino

BUS ENGINE COMPARTMENT FIRE PROTECTION SYSTEM FIREPRO TEST REPORT PEER REVIEW

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Southern California Gas Company Customer Programs Department

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

RF TEST REPORT. ZTE Corporation SRQ-VFD510 ZTE LTE/WCDMA/GSM GPRS RXC RF07

Test report. ifesesws^ Date: Number: T /17 Project file: C Pages: Product: Fixed general purpose LED luminaire

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

INTERNATIONAL STANDARD

Prisma Plus Assembly Guide. System G

Fibre (TIA) Field Test Specification

TECHNICAL REPORT IEC TR General testing procedures for medical electrical equipment. Edition

Provläsningsexemplar / Preview TECHNICAL REPORT. Part 3-1: Conformity verification report for IEC :2001 General requirements

TEST REPORT No /9943/CPR

Procedure for the Approval of New Fire Detection and Alarm Technologies

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Copy of marking plate:

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly

INTERNATIONAL STANDARD

A measured step forward

Compliance with EN : 2006 Electrical apparatus for explosive atmospheres Type of Protection «n» for Zone 2

Australian/New Zealand Standard

RADIOCOMMUNICATIONS (EMC STANDARDS) NOTICE 2004 No. 2

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

Installation instructions

NVLAP LAB CODE In Situ Temperature Measurement Test Report. For. AOK LED Light Company Limited. (Brand Name: AOK)

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

DESIGN MANUAL MODEL GIR900 INFRARED COMBUSTIBLE GAS SENSOR

Fire detection and alarm systems. Part 4: Power supply equipment (ISO :2003, MOD) AS (Incorporating Amendment No.

SOUTH AFRICAN NATIONAL STANDARD

CE marking & your legal obligations

INTERNATIONAL STANDARD

Survey of electrical equipment installed in hazardous areas on tankers

IAS Accreditation Number UL International Germany GmbH Address Admiral Rosendahl Strasse 23 Neu Isenburg Germany

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

CVS 4 TEMPLATE CUTOUT SIZE: 180mm CVS 6 TEMPLATE CUTOUT SIZE: 250mm

UL TEST REPORT AND PROCEDURE

ISO INTERNATIONAL STANDARD. Hydrogen generators using fuel processing technologies Part 1: Safety

Transcription:

TEST REPORT N. TRP_297_12 CETACE Laboratory in collaboration with Electronic and Telecommunication Department of the University of Florence Title: IP23 test Reports consists of no. 16 pages Result: Pass Issued to: Videl S.r.l. Località Ponti di Pievescola 53031 Casole d Elsa (SI) Date: 2012/12/24 Page 1/ 16 Notified Body for Low Voltage Directive NB 2047 The test results refer exclusively to the described test piece and to the specified measuring conditions. Any extension of the results to other samples and measuring conditions is beyond the terms of reference of this document. 1. Object under test: - Equipment under test: Fixed luminaire - Manufacturer: Videl S.r.l. Località Ponti di Pievescola 53031 Casole d Elsa (SI) - Model: Modular 12 - Rated voltage: 230 V - Rated frequency: 50 Hz - Class of protection against electric shock: Class I - Lamp: Incandescent lamp with G4 cap - Rated wattage: 2 x 20 W - IP code: IP23 - Mobility: fixed apparatus - Supply connection: terminal block 2. Identification data: Laboratory Address: Via dei Cadolingi 6, int.6/7 50018 Scandicci (FI) - Italy Tel. 0039-055 7350530 Fax. 0039-055 756473 E-mail: cetace@analytical.it Registered Office: Via dell Industria, 24 36071 Arzignano (VI) Italy Tel. 0039-0444-452022 Fax. 0039-0444-671432 E-mail: info@analytical.it - Test sample: 1 - Identification number: 294/12 C - Receipt date: 2012/11/27 - Test performance date: 2012/12/07 3. Testing scope: In the attached documents are described the technical evaluations carried out on the fixed luminaire model Modular 12 manufactured by Videl S.r.l. Località Ponti di Pievescola 53031 Casole d Elsa (SI), as indicated at point 1 tested equipment data. Scope of the testing activity is to verify the compliance of the equipment to the technical specification listed at point 4 Test specification and all ones recalled. Scientific Manager (Prof. A. Liberatore)

Test Report n TRP_297_12 issued on: 12/12/24 pag. 2/16 4. Reference standards and documents: CEI EN 60598-2-1 (CEI 34-23) Luminaires. Part 2: Particular requirements. Section 1: Fixed general purpose luminaires, Technical file 3769 R (October 1997); CEI EN 60598-1 (CEI 34-21) Luminaires, Part 1: General requirements and tests, 9 th Edition, Technical File 9950 C (August 2009); CEI EN 60529 (CEI 70-1) Degrees of protection provided by enclosures (IP Code), 2 nd Edition, Technical File 3227 C (June 1997) with Amendment A1 (CEI 70-1;V1), Technical File 5682 (June 2000). 5. Procedures: The tests have been conducted, according to the internal procedure, in the laboratory CETACE on n. 1 sample identified by the number 294/12 C, new and in the conditions in which it has been delivered by the customer. The temperature and the damp environment of laboratory they are maintained within (23±3) C, (50±15)% RH. The measures and the tests carried out in the present document have been performed with instrumentation that have a degree of uncertainty into in the suitable limits in the document CTL251B and declared inside the procedures of test. 6. Results: Clause Test Standard Result Environment 6.1 IP2X test CEI EN 60598-2-1, CEI EN 60598-1, CEI EN 60529, PASS CETACE Laboratory CEI EN 60529/A1 6.2 IPX3 test CEI EN 60598-2-1, CEI EN 60598-1, CEI EN 60529, CEI EN 60529/A1 PASS CETACE Laboratory Tester (Eng. L. Signorini) Lab Manager (Eng. M. Pignotti) Scientific manager (Prof. A. Liberatore)

Test Report n TRP_297_12 issued on: 12/12/24 pag. 3/16 6.1 IP2X test Basic standard: CEI EN 60598-2-1,CEI EN 60598-1,CEI EN 60529,CEI EN 60529/A1 Tested in: CETACE Laboratory Performed by: Eng. Lorenzo Signorini (CETACE Laboratory Tester) Assisted by: - Test equipment: Internal Equipment Manufacturer Model Calibration date Calibration expire Number Jointed test finger PTL P. 10.14 422 2011/08/01 2014/08/01 Test setup: Accidental contacts detector ATE = 60 = = The EUT has been mounted and wired as in normal use. The test has been executed using the jointed test finger (showed in the following picture), connected to the detector of accidental contact, with a force of 10 N ± 10%.

Test Report n TRP_297_12 issued on: 12/12/24 pag. 4/16 Acceptance conditions: 6.1 (follow) No contact permitted with live parts by the relevant test probe for first characteristic IP numeral 2. Results: The jointed test finger did not touch live parts of luminaire. The equipment is in compliance with the present clause. Actions used for passing the test: =

Test Report n TRP_297_12 issued on: 12/12/24 pag. 5/16 6.2 IPX3 test Basic standard: CEI EN 60598-2-1,CEI EN 60598-1,CEI EN 60529,CEI EN 60529/A1 Tested in: CETACE Laboratory Performed by: Eng. Lorenzo Signorini (CETACE Laboratory Tester) Assisted by: - Test equipment: Test setup: Equipment Manufacturer Model IPX3 IPX4 test apparatus A.T.S. Galbusera Internal Number Calibration date Calibration expire 03-30-C 223 2012/02/25 2015/02/25 Timer Hanhart Prisma 400 433 2011/07/12 2013/01/12 Multimeter Fluke 867B 279 2012/09/05 2013/09/05 Thermocouple module Electric strength equipment Dynamometric Screwdriver Digital caliper Dial pressure gauge Fluke 80-TK 309 2011/07/06 2013/07/06 Elektrotechn Laboratorium Korntal D- 7015 Stahville Mitutoyo = UH28M 406 2012/12/06 2013/12/06 Torsiometer 760/30 Absolute Digimatic A quadrante ø = 95 mm 370 2010/09/08 2013/09/08 308 2011/07/22 2013/07/22 300 2011/11/30 2013/11/30 The device under test has been mounted and wired as in normal use and placed on the turning plate of the IPX3 IPX4 test apparatus. The screws fixing the plastic cover have been tightened with a torque equal to 0,33 Nm. The test equipment has been regulated to obtain an arc oscillation of about 120 (60 on either side of the vertical). The time of one complete oscillation (2x120 ) has been 4 s and the EUT has been turned about its vertical axis at a rate of 1r/min (see the following picture).the device under test has been sprayed from every direction with water for 10 min by means of the spray apparatus described in Test equipment.

Test Report n TRP_297_12 issued on: 12/12/24 pag. 6/16 6.2 (follow) After the 10min period, the luminaire has been switched off and allowed to cool naturally whilst the water spray is continued for a further 10 min. Before the test has been verified that the water was at a temperature of 15 C ± 10 C and the water pressure at the inlet of the apparatus was approximately 80 kn/m 2. Acceptance conditions: After completion of the test, the luminaire shall withstand the electric strength test specified in Section 10 of standard CEI EN 60598-1. Moreover, for luminaire without drain holes, there shall be no water entry. Results: After the test, no traces of water inside the enclosure have been found. After the test has been performed the electric strength test applying 1460 V @ 50 Hz between live parts and mounting surface and between live parts and metal parts of the luminaire. The equipment is in compliance with the present clause. Actions used for passing the test: =

Test Report n TRP_297_12 issued on: 12/12/24 pag. 7/16 Annex 1: Picture of Equipment Under Test

Test Report n TRP_297_12 issued on: 12/12/24 pag. 8/16 Annex 1(follow)

Test Report n TRP_297_12 issued on: 12/12/24 pag. 9/16 Annex 2: Pictures of IP2X test

Test Report n TRP_297_12 issued on: 12/12/24 pag. 10/16 Annex 2 (follow)

Test Report n TRP_297_12 issued on: 12/12/24 pag. 11/16 Annex 3: Pictures of IPX3 test

Test Report n TRP_297_12 issued on: 12/12/24 pag. 12/16 Annex 3 (follow)

Test Report n TRP_297_12 issued on: 12/12/24 pag. 13/16 Annex 3 (follow)

Test Report n TRP_297_12 issued on: 12/12/24 pag. 14/16 Annex 3 (follow)

Test Report n TRP_297_12 issued on: 12/12/24 pag. 15/16 Annex 3 (follow)

Test Report n TRP_297_12 issued on: 12/12/24 pag. 16/16