TEST REPORT N. TRP_297_12 CETACE Laboratory in collaboration with Electronic and Telecommunication Department of the University of Florence Title: IP23 test Reports consists of no. 16 pages Result: Pass Issued to: Videl S.r.l. Località Ponti di Pievescola 53031 Casole d Elsa (SI) Date: 2012/12/24 Page 1/ 16 Notified Body for Low Voltage Directive NB 2047 The test results refer exclusively to the described test piece and to the specified measuring conditions. Any extension of the results to other samples and measuring conditions is beyond the terms of reference of this document. 1. Object under test: - Equipment under test: Fixed luminaire - Manufacturer: Videl S.r.l. Località Ponti di Pievescola 53031 Casole d Elsa (SI) - Model: Modular 12 - Rated voltage: 230 V - Rated frequency: 50 Hz - Class of protection against electric shock: Class I - Lamp: Incandescent lamp with G4 cap - Rated wattage: 2 x 20 W - IP code: IP23 - Mobility: fixed apparatus - Supply connection: terminal block 2. Identification data: Laboratory Address: Via dei Cadolingi 6, int.6/7 50018 Scandicci (FI) - Italy Tel. 0039-055 7350530 Fax. 0039-055 756473 E-mail: cetace@analytical.it Registered Office: Via dell Industria, 24 36071 Arzignano (VI) Italy Tel. 0039-0444-452022 Fax. 0039-0444-671432 E-mail: info@analytical.it - Test sample: 1 - Identification number: 294/12 C - Receipt date: 2012/11/27 - Test performance date: 2012/12/07 3. Testing scope: In the attached documents are described the technical evaluations carried out on the fixed luminaire model Modular 12 manufactured by Videl S.r.l. Località Ponti di Pievescola 53031 Casole d Elsa (SI), as indicated at point 1 tested equipment data. Scope of the testing activity is to verify the compliance of the equipment to the technical specification listed at point 4 Test specification and all ones recalled. Scientific Manager (Prof. A. Liberatore)
Test Report n TRP_297_12 issued on: 12/12/24 pag. 2/16 4. Reference standards and documents: CEI EN 60598-2-1 (CEI 34-23) Luminaires. Part 2: Particular requirements. Section 1: Fixed general purpose luminaires, Technical file 3769 R (October 1997); CEI EN 60598-1 (CEI 34-21) Luminaires, Part 1: General requirements and tests, 9 th Edition, Technical File 9950 C (August 2009); CEI EN 60529 (CEI 70-1) Degrees of protection provided by enclosures (IP Code), 2 nd Edition, Technical File 3227 C (June 1997) with Amendment A1 (CEI 70-1;V1), Technical File 5682 (June 2000). 5. Procedures: The tests have been conducted, according to the internal procedure, in the laboratory CETACE on n. 1 sample identified by the number 294/12 C, new and in the conditions in which it has been delivered by the customer. The temperature and the damp environment of laboratory they are maintained within (23±3) C, (50±15)% RH. The measures and the tests carried out in the present document have been performed with instrumentation that have a degree of uncertainty into in the suitable limits in the document CTL251B and declared inside the procedures of test. 6. Results: Clause Test Standard Result Environment 6.1 IP2X test CEI EN 60598-2-1, CEI EN 60598-1, CEI EN 60529, PASS CETACE Laboratory CEI EN 60529/A1 6.2 IPX3 test CEI EN 60598-2-1, CEI EN 60598-1, CEI EN 60529, CEI EN 60529/A1 PASS CETACE Laboratory Tester (Eng. L. Signorini) Lab Manager (Eng. M. Pignotti) Scientific manager (Prof. A. Liberatore)
Test Report n TRP_297_12 issued on: 12/12/24 pag. 3/16 6.1 IP2X test Basic standard: CEI EN 60598-2-1,CEI EN 60598-1,CEI EN 60529,CEI EN 60529/A1 Tested in: CETACE Laboratory Performed by: Eng. Lorenzo Signorini (CETACE Laboratory Tester) Assisted by: - Test equipment: Internal Equipment Manufacturer Model Calibration date Calibration expire Number Jointed test finger PTL P. 10.14 422 2011/08/01 2014/08/01 Test setup: Accidental contacts detector ATE = 60 = = The EUT has been mounted and wired as in normal use. The test has been executed using the jointed test finger (showed in the following picture), connected to the detector of accidental contact, with a force of 10 N ± 10%.
Test Report n TRP_297_12 issued on: 12/12/24 pag. 4/16 Acceptance conditions: 6.1 (follow) No contact permitted with live parts by the relevant test probe for first characteristic IP numeral 2. Results: The jointed test finger did not touch live parts of luminaire. The equipment is in compliance with the present clause. Actions used for passing the test: =
Test Report n TRP_297_12 issued on: 12/12/24 pag. 5/16 6.2 IPX3 test Basic standard: CEI EN 60598-2-1,CEI EN 60598-1,CEI EN 60529,CEI EN 60529/A1 Tested in: CETACE Laboratory Performed by: Eng. Lorenzo Signorini (CETACE Laboratory Tester) Assisted by: - Test equipment: Test setup: Equipment Manufacturer Model IPX3 IPX4 test apparatus A.T.S. Galbusera Internal Number Calibration date Calibration expire 03-30-C 223 2012/02/25 2015/02/25 Timer Hanhart Prisma 400 433 2011/07/12 2013/01/12 Multimeter Fluke 867B 279 2012/09/05 2013/09/05 Thermocouple module Electric strength equipment Dynamometric Screwdriver Digital caliper Dial pressure gauge Fluke 80-TK 309 2011/07/06 2013/07/06 Elektrotechn Laboratorium Korntal D- 7015 Stahville Mitutoyo = UH28M 406 2012/12/06 2013/12/06 Torsiometer 760/30 Absolute Digimatic A quadrante ø = 95 mm 370 2010/09/08 2013/09/08 308 2011/07/22 2013/07/22 300 2011/11/30 2013/11/30 The device under test has been mounted and wired as in normal use and placed on the turning plate of the IPX3 IPX4 test apparatus. The screws fixing the plastic cover have been tightened with a torque equal to 0,33 Nm. The test equipment has been regulated to obtain an arc oscillation of about 120 (60 on either side of the vertical). The time of one complete oscillation (2x120 ) has been 4 s and the EUT has been turned about its vertical axis at a rate of 1r/min (see the following picture).the device under test has been sprayed from every direction with water for 10 min by means of the spray apparatus described in Test equipment.
Test Report n TRP_297_12 issued on: 12/12/24 pag. 6/16 6.2 (follow) After the 10min period, the luminaire has been switched off and allowed to cool naturally whilst the water spray is continued for a further 10 min. Before the test has been verified that the water was at a temperature of 15 C ± 10 C and the water pressure at the inlet of the apparatus was approximately 80 kn/m 2. Acceptance conditions: After completion of the test, the luminaire shall withstand the electric strength test specified in Section 10 of standard CEI EN 60598-1. Moreover, for luminaire without drain holes, there shall be no water entry. Results: After the test, no traces of water inside the enclosure have been found. After the test has been performed the electric strength test applying 1460 V @ 50 Hz between live parts and mounting surface and between live parts and metal parts of the luminaire. The equipment is in compliance with the present clause. Actions used for passing the test: =
Test Report n TRP_297_12 issued on: 12/12/24 pag. 7/16 Annex 1: Picture of Equipment Under Test
Test Report n TRP_297_12 issued on: 12/12/24 pag. 8/16 Annex 1(follow)
Test Report n TRP_297_12 issued on: 12/12/24 pag. 9/16 Annex 2: Pictures of IP2X test
Test Report n TRP_297_12 issued on: 12/12/24 pag. 10/16 Annex 2 (follow)
Test Report n TRP_297_12 issued on: 12/12/24 pag. 11/16 Annex 3: Pictures of IPX3 test
Test Report n TRP_297_12 issued on: 12/12/24 pag. 12/16 Annex 3 (follow)
Test Report n TRP_297_12 issued on: 12/12/24 pag. 13/16 Annex 3 (follow)
Test Report n TRP_297_12 issued on: 12/12/24 pag. 14/16 Annex 3 (follow)
Test Report n TRP_297_12 issued on: 12/12/24 pag. 15/16 Annex 3 (follow)
Test Report n TRP_297_12 issued on: 12/12/24 pag. 16/16