O3TH. Ozone Detector c/w Indicator for Temperature/Humidity. Automatikprodukter. Features. Technical Data. Description. Ordering Codes. Dec.

Similar documents
Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

Nitrogen Dioxide Stand-Alone Detector - Analog, ModBus

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

Analog Room Pressure Monitor RPC Series

Carbon Monoxide Transmitter

Toxic Gas Detection. Model F12. Toxic Gas Detection

Carbon Monoxide (CO) Gas Detector, 4-20mA or 2-10Vdc

Two-Channel Gas Controller

CO2 & Oxygen Monitor Operating Instructions Model: RAD

User Manual R1.0 CO2Meter, Inc. Personal CO2 Monitor SAN-10

Oxygen Monitor Operating Manual

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

Operating Instructions XWA11V XWA11V. Walk-In Temp / Door /Alarm / Light Module

Warranty Registration

Danfoss gas detection unit Type GD Heavy Duty

Model D12-IR. Digital Gas Transmitter...

Operating Instructions XWA11V. XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

Danfoss gas detection units

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

User's Guide. CO 2 Monitor. Model CO200

ELECTRONIC COMMUNICATING THERMOSTAT

XWA11V. Walk-In Temp / Door /Alarm / Light Module

ETNC24-FC-BAC-PIR-01 Owner s manual & Technician Settings

02/11/2015

Touch Screen Thermostat. MTSC/SUPER/CO2, MTSC24/SUPER/CO2 Series. MTS/SUPER/CO2, MTS24/SUPER/CO2 Series. Owner s manual and technician settings

Product Manual SZ1145

LCF Touch Modbus Datasheet Application Security Advice Caution

0-10 V Wall & Duct Humidistat Installation Instructions

CO2 Monitor Operating Instructions

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

RSMFM-2R MULTIFUNCTIONAL

Product Manual SZ1144

GLD-30 Gas Leak Detector

Thermostats. Digital Programmable. GEAppliances.com

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System

Ammonia Leak Detector Manual

02/11/2015

INSTALLATION & USER MANUAL

OPERATION MANUAL. ComfortSense 3000 Series Model No. L3011C Non-Programmable Thermostat. Table of Contents. L3011C Thermostat

RS Pro Infrared Temperature Sensor

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

Model D12. Digital Gas Transmitter

SC Installation, Operation & Application Guide

TER Active Room Temperature Sensor (Controller),

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

Carbon Monoxide CO Transmitter ADT-X3-1110

INSTALLATION AND OPERATING INSTRUCTIONS

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

RC-90 / RC-90B Single Stage Heat/Cool Thermostat for Zone Control Systems Installation Instructions

Model : PRT-EN Model: PRT-EN1

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Oxygen (O2) Single-Point Gas Detection System

Danfoss gas detection units

I/A Series 716C 1/16 DIN Temperature Controller

Series Temperature Controller Instruction Sheet

Duct and Rough Service Carbon Monoxide Sensor

RC-101 Heat Pump Real Time Pricing System 2 Stage Heat / 1 Stage Cool

Technicians Manual Single Compressor

User Manual. PolyGard Gas Controller MGC3. Two-Channel Analog Gas Controller Serial Number _E _0907. September 2007

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications

SAT- 3 Installation Setup Guide

Model: PRT-TS / PRT-NTS

DIGITAL INDICATOR JIR-301-M

Model: Slimline-N. 1 Slimline Series

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Thermostats. Digital Non-Programmable. GEAppliances.com. Owner s Manual & Installation Instructions RAK148D2 RAK164D2

Underfloor Heating Programmable Thermostat

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

Inc Series Digital Gas Detector/Controller. Operation Manual

CLEANROOM MONITOR CR3A Network - Installation Instructions

RTD TEMPERATURE SENSING SYSTEM

S304 and S305 Dust Emission Monitors. User Manual. Distributor

QD6310. Fixed Gas Detector Operation Manual

WARNING Important Safety Information

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

RCS Residential Control Systems Inc.

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Carbon Monoxide (CO) Gas Detector, 4-20mA GCO. Automatikprodukter. Oct. 15. Features. Technical Data. Design Features. Application.

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

T-32-TS Touchscreen Thermostat. Installation Manual

B-40/B-41 Modulating Temperature Controller

HEAT HEAT HEAT COOL COOL

DGS - Danfoss Gas Sensor Check / Calibration Procedure

XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

MF-PFA ver 3.x. Micaflex PFA ver 3. Pressure- and Flow transmitter with alarmfunction. Installation- & Operation manual [Dok. id: mi-303gb_180528]

Model: Edge-HC. 1 edge-hc

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

WARNING Important Safety Information

Warranty Registration

BST-MG01 Single Gas Detecting Alarm Manual Instruction

Water Detection Controllers

Transcription:

Indicator for Temperature/Humidity Dec.11 Features - Real time detection of ambient ozone gas level - Full time indicate O3 level - Wall mount with LCD display - Temperature & humidity detection - The on/off output for control a fan, O3 generator or an alarm - Provide an analogue output with linearover full range output - Adressing for RS485 mode. eg. Modbus Technical Data Gas Ozone O3 Detection principle Semiconductor ozone gas senso Warm up time First time 96 hours Operational 1 hour Mounting height 300mm above floor O3 Measuring range 10-1000ppb Description O3 detector including digital measurement value processing and temperature compensation for the continuous monotoring of ozone concentration in the ambient air. For the detection of ozone within a wide range of industrial and commercial applications. Relay output Current Ranges Analogue output Output resolution One dry contact output 2A switching (resistance load) Four to be selected to control the relay turn-on/ turn-off 0-10Vdc linearzed 10Bit Temperature measurement 0-+50C settings 5-+45C Humidity measurement 0-99% RH settings 5-+95%RH Serial Interface RS485 Rate 9600/14400/19200 (default) 28800, 38400bps programmable selection Base address 3 indepedent Nodes Max 31 in a network Power supply 24Vac/dc Display resolution 1 ppb Accuracy +/- 10 ppb + 20% of reading Expected lifetime More than 5 years normal opera ting environmontal Humidity range 5-95% rh non-condensing Operating range 5 up to +45C Protection Class IP30 Fire proof ABS material Ordering Codes 2 2M 12 12M Alarm Units AAW 24 AAW 230 OA 24 OAW 24 OAW 230 Ozone Detector 10-1000ppb (0,01 -- 1ppm) c/w one relay output Ozone Detector 10-1000ppb (0,01 -- 1ppm) c/w one relay output and Modbus Ozone Detector 10-1000ppb (0,01 -- 1ppm) c/w one relay and analogue output Ozone Detector 10-1000ppb (0,01 -- 1ppm) c/w one relay and analogue output, Modbus Warning Siren 24Vdc 98-108dB Warning Siren 230Vac 98-108dB Flash Light 24Vdc red Combined Warning Siren and Flash Light 24Vdc Combined Warning Siren and Flash Light 230V Warning Sign Gasalarm Warning Sign GASALARM 24Vac/dc

Important information Ozone Detector c/w Indicator for Temperature/Humidity Dec.11 1. Always cut off power before mounting, removing and cleaning the monitor. 2. Read all of the information in this datasheet before mounting the detector. 3. Notice the supply power voltage of the transmitter: 24Vac/dc. Do not install the transmitter on voltages higher than marked on the transmitter Mounting and Wire Connection 1. Cut off power first. Simualtaneously depress the 2 clips on either of the sides of the detector gently with your nails or other unsharp tools, then move off the face part. 2. Mount the detector on the place where you want to detect O3 level 0,3m above floor. Do not behind a door, in a corner, in direct sunlight and near any heat or steam sources. Do not mount the detector in the direction of the outlet of the Ozone generator or in places where wind pass through. 3. Mount the wall plate first. Place the detector against the wall at desired location; make sure wires can be passed through the holes of the wall plate. 4. Connect wires to terminal strips, (see the label attached on the wall plate and fig.3). Make sure wiring connection correct and scure. 5. Cover the face part to the wall plate We reserve the right to make changes and improvements in our products which may effect the accuracy of the information contained in this leaflet.

Indicator for Temperature/Humidity Dec.11 LCD and Buttons humidity temperature Locked Relay on O3 value Operation 1. If you use the monitor for the first time or it hasn t been used for a long time, then it should be energized for more than 48 hours before it come into normal use. If you have placed it in the direction of the outlet of the Ozone monitor or in places where wind pass through, then the measurement of the Ozone monitor will be incorrect. In this situation, please place the Ozone monitor in normal environment and keep it energized for at least 24 hours, and then calibrate its zero point following step 10. Then the monitor will return to normal use again. When the ozone measurement range overstep the maximum measurement, the ozone sensor can be resumed after a long time rest, and then it will return to normal use again. 2. Temperature measurement range is 0~50!, accuracy 0.5!, temperature setting range is 5~45!. Humidity measurement range is 5~99%RH, accuracy 1%RH, humidity setting range is 5~95%RH. Ozone measurement range is 10~1000ppb, accuracy 1ppb and setting range is 40~1000ppb, its maximum measurement limited is 2000ppb. 3. Turn on: Turn on the monitor by press power for 2 seconds. Temperature measurement displays on the right of upper line of LCD, the humidity measurement displays on the left of upper line of LCD. The preheating time of ozone sensor displays on the below line and the time is set to 300 seconds(default). The preheating time can be changed in parameter setup. After it is counted down to 0, ozone level will be displayed. 4. Switch setting value: press switch key to exchange setting value from between ozone and temperature/humidity. But for the model, temperature setting is un-effective. 5. Setting O3 value: Once switching to ozone setting, the ozone number is blinking, it indicates that the O3 value can be set by (tangent down) and (tangent up)key. Increase or decrease 1ppb each time by pressing and rapid increase or decrease by pressing key for more than 2 seconds. 6. Lock setting value: Simultaneously depress the (tangent down and tangent up)key more than 5 seconds up to the symbol (lock) appearing on the LCD. Then the setting value is locked to avoid wrong operation. 7. Unlock: Under the locked mode, simultaneously depress (tangent down) and (tangent up) up to (lock) disappear.

Indicator for Temperature/Humidity Dec.11 8. When DIP4 is set to OFF(details see below Parameter Setup): The relay will turn on when O3 measurement < O3 setting with ON symbol appearing on the right of LCD. When O3 measurement <O3 setting, the relay will turn off with ON disappearing. When DIP4 is set to ON(details see below Parameter Setup): The relay will turn on when O3 measurement > O3 setting with ON symbol appearing on the right of LCD. When O3 measurement < O3 setting, the relay will turn off with ON disappearing. The differential of ozone setting, please refer to Parameter Setup. 9. The scale bards on the right of LCD indicates the analog output. It is un-effective to this model. 10. Calibration of the zero of ozone sensor: after using the ozone sensor for more than one year, the sensor need to be calibrated again. Put the monitor into the space of zero ozone and preheating it, press switch key for about 20 seconds until X10 symbol appearing on the right of ozone number, then loosen switch key, the monitor starts auto zero calibration. After 210 seconds until X10 symbol disappearing, it indicates the zero calibration finished. Cancel the zero calibration: press switch key for about 20 seconds until X10 symbol appearing and then keep on press switch key for about 20 seconds until X10 symbol disappearing. It indicates the zero has no any calibration, it s still 0. Note: Auto zero calibration can be done only when ozone measurement is above 5ppb. And keep the controller in the zero ozone environment before X10 symbol disappears. Parameter Setup ( Service Manual V.O3_210) Cut off power and simultaneously depress the 2 clips on either of the sides of the monitor gently with your nails or other unship tools. Move the face cover, there is a set of 4 Dipswitches on the right of the circuit board. DIP1 ON - set parameter OFF- normal use Leaving factory: OFF DIP2 ON - Fahrenheit OFF- Celsius Leaving factory: OFF DIP3 Un-effective for the model Leaving factory: OFF DIP4 ON- For decrease ozone (to control ventilation system) OFF- For increase ozone (to control an ozone generator) Leaving factory: OFF Please put DIP1 to ON, press power key to turn it on, and set the following parameters. Press switch for switching parameters, ( tangent down,tangent up) for adjusting values. LCD Display Parameter Setting Range Default -00 Temperature modification +/-3.0C 0.0C -01 Humidity modification +/-9%RH 0-02 Ozone value correction +/-30ppb 0.0-03 Warm up time of the ozone detector 1-900sec 300 ( no output use, neither 0-10vdc nor on/off, is recommended before ozone measurement becomes stable or warm up is finished) -04 Un-effective for the model 0.0

Indicator for Temperature/Humidity Dec.11 LCD Display Parameter Setting Range Default -05 Un-effective for the model 0-06 Minus differential of ozone 5-30 20 of control the delay e.g. the setting value is 10 and O3 is 50ppb, if measured O3<50-10ppb, the relay will be on (DIP4=OFF) or will be off (DIP4=ON). -07 Positive differential of ozone of 5-100 50 control the delay e.g. the setting value is 20 and O3 setting is 50ppb, if measured O3>50+20ppb, the relay will be off (DIP4=OFF) or will be on (DIP4=ON). -08 The state of the detector electrify 0: turn off after electrify 2 after power broken 1: turn on after electrify 2: keep on the last state -09 Setting RS485 address 0-250 0-10 RS485 communication rate selection 1: 9600bps 2: 14400bps 3 3: 19200bps 4: 28800bps 5: 38400bps RESET: Put the DIP1 to ON and press switch key for about 25 seconds until the detector is off, then all the setting return to the default. Annex: Ozone Measurement Emendation Put the four DIPs to the upper position to be ON and then start ozone emendation. 1) The digit displayed on the upper left of the LCD indicates the demarcation point that is right now being emended. Display range: 01, 02, 03, 04, 05, 06, 07, 08, 09, 10 2) The digit displayed on the upper right of the LCD indicates the ozone measurement at the current demarcation point. Display range: Y1, Y2, Y3, Y4, Y5, Y6, Y7, Y8, Y9, Y10 3) The digit displayed on the bottom line corresponds to the A/D transition level of X axial. 4) The non-twinkling figure indicates the real-time ozone measurement detected by the sensor. 5) The twinkling figure indicates the demarcation point that needs to be set Display range: X1, X2, X3, X4, X5, X6, X7, X8, X9, X10

Indicator for Temperature/Humidity Dec.11 Y ( ozone measurement) 1000PPB 7 6 5 4 3 2 1 1023 X (A/D transition) Steps: 1) Energize the controller 2) Put the four DIPs to the upper position to be ON and wait until the digits displayed on the LCD to be stable 3) Demarcate demarcation point 1 (0), write down the un-twinkling point of X1 4) Press switch to the first demarcation point (N=1) 5) Press (tangent down) or (tangent up) to adjust the twinkling figure until it equals to X1. Then the demarcation of X1 is finished 6) Now go to demarcation point 2, put the controller in sample gas 7) Write down the un-twinkling point of X2 and Y2 8) Press switch to the second demarcation point (N=2) 9) Press (tangent down) or to (tangent up) adjust the twinkling figure until it equals to Y2 10) Press switch, then the following figure starts twinkling 11) Press (tangent down) or (tangent up) to adjust the twinkling figure until it equals to X2. Then the demarcation of X2 is finished 12) Repeat steps 6-11 to finish the emendation of demarcation point 3 to 10 13) After the emendation to all demarcation points, put the four DIPs to OFF.

Indicator for Temperature/Humidity Dec.11 Table: Ozone measurement in normal air Y1=0 Ozone measurement in sample gas1 Y2 Ozone measurement in sample gas2 Y3 Ozone measurement in sample gas3 Y4 Ozone measurement in sample gas4 Y5 Sensor output in normal air X1 (zero point) Sensor output in gas1 X2 Sensor output in gas2 X3 Sensor output in gas3 X4 Sensor output in gas4 X5 Press switch key for about 25 seconds until the monitor is off, then all the settings return to the default. If warm-up time is less than 3 months before leaving factory, then do emendation as the second row of the following table. If warm-up time is more than 3 months before leaving factory, then put four DIPs to ON and press switch key for about 25 seconds until the detector is off, then do emendation as the third row of the following table. Warm-up time 0ppb 40ppb 80ppb 200ppb 300ppb 500ppb 600ppb 700ppb 900ppb 999ppb Less than 3 months 1000 847 717 500 420 338 315 291 264 254 More than 3 months 870 720 580 500 420 338 315 291 264 254

Indicator for Temperature/Humidity Dec.11 Guidelines on How to Measure Ozone The following information is presented to help users operate their Ozone Detector in the most effective and efficient manner. General Ozone is heavier than air and tends to sink. Thus detection of leaks from ozone generating equipment should be performed at the most appropriate position. Ozone will react and decompose on surfaces such as walls, furniture etc. Smell is not a reliable test for the presence or concentration of ozone as the odour threshold varies widely between people and is affected by local ambient conditions. Permanent Controller Placement The Ozone Detector has been designed to measure the ambient concentration of ozone. The controller must not be placed directly in an ozone stream. For indoor local area monitoring attach the controller to an inert surface with the inlet unobstructed. For leak detection mount the unit near the ozone equipment. Ensure that the controller is protected from excessive water splashing, dust, vibration, excessive heat or cold, high concentrations of ozone and excessive swings in humidity. False Readings The Ozone Detector has been designed to respond selectively to ozone, however other oxidizing gases such as chlorine and nitrogen dioxide can generate false readings if they are at high concentrations. High concentrations of hydrocarbon gases such as vapours of alcohol, oils and solvents can reduce and mask the concentration of ozone.