UL TEST REPORT AND PROCEDURE

Similar documents
UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

IEC60601_1K. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

UL TEST REPORT AND PROCEDURE

REVISION HISTORY Rev Description Author. Approved by Date A Initial release per ECO Dean King Dean King November 16, 2012

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

File E Project 05ME Issued: November 1, 2005 Revised: February 27, 2009 REPORT

UL TEST REPORT AND PROCEDURE

COVER PAGE FOR TEST REPORT

File E Project 97SC January 21, 1998 REPORT

Certificate of Compliance

UL TEST REPORT AND PROCEDURE

STANDARDS UPDATE NOTICE (SUN) ISSUED: August 23, 2017

EU Declaration of Conformity

Certificate of Compliance

INTERNATIONAL STANDARD

File S789 Project 04ME December 20, 2005 REPORT CONTROL UNIT (UOJZ) * * * * * * * * * * * * * * * * * * * * *

C E R T I F I C A T E O F C O M P L I A N C E

Certificate of Compliance

File E Project 08ME October 7, 2008 REPORT. UNLISTED COMPONENT - Attachment Plugs, Fuseless. For Use Only In

Declaration of Conformity

Certificate of Compliance

Field Certification Certificate of Compliance

Listing Constructional Data Report (CDR)

HISTORICAL OF SAMPLE RECEIVED EXAMINED SECTIONS

INTERNATIONAL STANDARD

CLASSIFICATION Constructional Data Report (CDR)

Regulatory Compliance Training for Non-Safety Engineers

Performer Cuspidor. Installation Instructions. (For Performer III Chair & International Performer I Chair) You Will Need. About This Install

TECHNICAL REPORT IEC TR General testing procedures for medical electrical equipment. Edition

INTERNATIONAL STANDARD

Certificate of Compliance

38-SDMS-03 SPECIFICATIONS FOR LV DIGITAL PANEL METERS

Australian/New Zealand Standard

SPECIFICATION AND PERFORMANCE MDP CONNECTOR SERIES

EU Declaration of Conformity

Technical evaluation of the Ningbo Longmax Electronic Co., Ltd LM-201A battery operated carbon monoxide (CO) Detector Type B to EN :2010.

TEST REPORT IEC Safety of household and similar electrical appliances Part 2: Particular requirements for massage appliance

This is a preview - click here to buy the full publication

GETTING STARTED GUIDE NI DIO, 5 V/TTL, Bidirectional, 7 μs

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

INTERNATIONAL STANDARD NORME INTERNATIONALE

This is a preview - click here to buy the full publication

Part 2-55: Medical electrical equipment. Particular requirements for the basic safety and essential performance of respiratory gas monitors

Certification Supplement Manual

FLAME ITEM PART NO CLIENT REF. NO. DESCRIPTION DESIGNATION MANUFACTURER CLASS UL FILE NO.

Table of Contents FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS...

INTERNATIONAL STANDARD

Regulatory Information and Specifications

PAKISTAN STANDARD LED MODULES FOR GENERAL LIGHTING (SAFETY SPECIFICATIONS) PS: _5211/2017 ICS:

AC/DC Power Supply and Battery Charger Installation and Maintenance

FEB. 17 Rev. A1

K-SQ13, KA-SQ13, K-SQ14, KA-SQ14, KO-SQ13, KOA-SQ13, KO-SQ14, KOA-SQ14, K-SQ13C, KA-SQ13C, K-SQ14C, KA- SQ14C, KO-SQ13C, KOA-SQ13C, KO-SQ14C,

INTERNATIONAL STANDARD

AS/NZS :2003 Luminaires - Part 1: General requirements and tests

This is a preview - click here to buy the full publication. High-voltage switchgear and controlgear

RECOGNIZED COMPONENT Constructional Data Report (CDR)

MDA Series. DC Axial Flow Fans with Low-Speed Alarm. $$ The Low-Speed Alarm: "Features

GASTEC QA. Approval Requirements 31-2

INTERNATIONAL STANDARD

GASTEC QA. Approval Requirements 31-1

This document is a preview generated by EVS

Demystifying Power Tap Use in Healthcare Settings John Garbarino Sr. Marketing Manager, Commercial/Industrial Leviton Manufacturing Co.

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

SECTION ISOLATED POWER SYSTEMS

What does doesn t a power supply have to comply with these days!

An Urgent Bulletin from CSA Group

Descriptive Report and Test Results

GETTING STARTED GUIDE NI DI, 30 V, Sourcing, 7 μs

AUGUST 2016 CONTENTS:

Dansereau Dental. P r e - C o n s t r u c t i o n G u i d e

INTERNATIONAL STANDARD

HYTEK ATEX APPROVED TANK ALARM

INTERNATIONAL STANDARD

MODEL B2 INSTALLATION MANUAL

Listing Constructional Data Report (CDR)

Test Report. Appliance EMF Testing

Test Report issued under the responsibility of:

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

INTERNATIONAL STANDARD

HARMONY LED385 EXAMINATION LIGHTING SYSTEM

AS/NZS IEC :2013

INTERNATIONAL STANDARD

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

INTERNATIONAL STANDARD

File Ex643 Project 03NK31930 Project 04NK24425 Project 05NK25712 Project 06NK15719 Project 06NK06003 Project 06NK24531

ISO INTERNATIONAL STANDARD

Standards Update Notice (SUN) Issued: February 2, 2017

Certificate of Compliance

UL Electrical Equipment for Measurement, Control, and Laboratory Use; Part 1: General Requirements, Second Edition

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

GETTING STARTED GUIDE NI AI, ±29.4 mv/v, 24 Bit, 10 ks/s/ch Simultaneous, 350 Ω Quarter-Bridge Completion

Transcription:

Issue Date: 2016-01-22 Page 1 of 9 Report Reference # E182560-V4-S48 UL TEST REPORT AND PROCEDURE Standard: ANSI/AAMI ES60601-1 (2005/(R)2012 + A1:2012, C1:2009/(R)2012 + A2:2010/(R)2012) - Amendment 1 - Revision Date 2012/08/21 CAN/CSA-C22.2 No. 60601-1:14 - Edition 3 - Revision Date 2014/03 Certification Type: Component Recognition CCN: QQHM2, QQHM8 (Power Supplies, Medical and Dental) Product: Switching Power Supply Model: LPS54-M Rating: Rated Input: 100-240 V, 50/60 Hz, 2 A; Rated Output: 15 Vdc, 4 A Applicant Name and Address: ASTEC INTERNATIONAL LTD - PHILIPPINE BRANCH 16TH FL LU PLAZA 2 WING YIP ST KWUN TONG KOWLOON HONG KONG This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the above referenced Standards. The products have been found to comply with the requirements covering the category and the products are judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable requirements of UL LLC ('UL') in accordance with the Follow- Up Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow-Up Service under the indicated Test Procedure. The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety. UL authorizes the applicant to reproduce the latest pages of the referenced Test Report consisting of the first page of the Specific Technical Criteria through to the end of the Conditions of Acceptability. Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. Prepared by: Cary Hu Reviewed by: Sammi Liang

Issue Date: 2016-01-22 Page 2 of 9 Report Reference # E182560-V4-S48 Supporting Documentation The following documents located at the beginning of this Procedure supplement the requirements of this Test Report: A. Authorization - The Authorization page may include additional Factory Identification Code markings. B. Generic Inspection Instructions - i. Part AC details important information which may be applicable to products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of this Test Report. ii. Part AE details any requirements which may be applicable to all products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of each Test Report. iii. Part AF details the requirements for the UL Certification Mark which is not controlled by the technical standard used to investigate these products. Products are permitted to bear only the Certification Mark(s) corresponding to the countries for which it is certified, as indicated in each Test Report.

Issue Date: 2016-01-22 Page 3 of 9 Report Reference # E182560-V4-S48 Product Description This is a switching mode power supply, open frame type, all electronic components are mounted on V-0 PWB, classified as Class I power supply.. Model Differences N/A Technical Considerations Classification of installation and use : For built-in Device type (component/sub-assembly/ equipment/ system) : Component Intended use (Including type of patient, application location) : Switching type power supply for general use with medical electrical equipment. Mode of operation : Continuous Supply connection : To be evaluated in end product. Accessories and detachable parts included : None Other options include : None The product was investigated to the following additional standards: N/A The product was not investigated to the following standards or clauses: Biocompatibility (ISO 10993-1), Clause 14, Programmable Electronic Systems, Electromagnetic Compatibility (IEC 60601-1-2) The degree of protection against harmful ingress of water is: Ordinary The mode of operation is: Continuous The product is suitable for use in the presence of a flammable anesthetics mixture with air or oxygen or with nitrous oxide: No Engineering Conditions of Acceptability For use only in or with complete equipment where the acceptability of the combination is determined by UL LLC. When installed in an end-product, consideration must be given to the following: The power supply is a built-in device as parts of medical equipment. The date of manufacture & S/N marked needs to be evaluated in the end-product. This power supply has been judged on the basis of the required creepage and clearances in the First Edition of the Standard for Medical Electrical Equipment, ANSI/AAMI ES 60601-1, Sub clause 8.9. This power supply has been evaluated as a Class I, continuous operation, ordinary Equipment and has not been evaluated for use in the presence of a flammable anesthetic mixture with air, oxygen, or nitrous oxide. An additional evaluation shall be made if the power supply is intended for use in other than Class I equipment. This power supply was tested on a 20A branch circuit. If used on a branch circuit greater than this, additional testing may be necessary. The power supply was evaluated as 2 MOOP between Primary to Secondary, 1 MOOP provided between the polarity of mains parts and 1 MOOP from Primary to Earth see insulation diagram for details. Consideration shall be given to measuring the temperatures on power electronic components and transformer windings when the power supply is installed in/with the end-use equipment. All transformers employ a Class F (155 C) insulation system. The secondary output circuit of the product is SELV.

Issue Date: 2016-01-22 Page 4 of 9 Report Reference # E182560-V4-S48 The following tests shall be performed in the end-product evaluation: Earthing and Potential Equalization Test, Temperature Test, Dielectric Voltage Withstand Tests, and Leakage Current Test The reference voltage for Dielectric Voltage Test in End Product: 310.7 Vrms, 514 Vpk for T1 This power supply shall be installed in compliance with the enclosure, mounting, spacing, casualty, markings and segregation requirements of the end use application. "Voltage or charge limitation" may need to reconsider if additional EMC filter is provided between appliance inlet/ power cord to the product. A suitable Mechanical, Electrical and Fire enclosure shall be provided in the end-use product. This power supply is operated up to 3050m above sea level as declared by manufacturer. Separation from secondary to earth need to evaluated in end product. End product Risk Management Process to include consideration of requirements specific to the Power Supply The input and output connectors are not suitable for field connection Proper bonding to the end-product main protective earthing termination is required End product Risk Management Process to consider the need for simultaneous fault condition testing End product Risk Management Process to consider the need for different orientations of installation during testing End product to determine the acceptability of risk in conjunction to insulation to resistance to heat, moisture, and dielectric strength End product to determine the acceptability of risk in conjunction to the movement of components and conductors as part of the power supply End product to determine the acceptability of risk in conjunction to the routing of wires away from moving parts and sharp edges as part of the power supply Temperature Test was conducted without Test Corner. End product to determine the acceptability of risk in conjunction to temperature testing without test corner as part of the power supply End product to determine the acceptability of risk in conjunction to the Cleaning and Disinfection Methods as part of the power supply End product to determine the acceptability of risk in conjunction to the Leakage of Liquids as part of the power supply End product to determine the acceptability of risk in conjunction to the Arrangement of Indicators as part of the power supply End product to determine the acceptability of risk in conjunction to the results of Mechanical Testing conducted as part of the power supply End product to determine the acceptability of risk in conjunction to the selection of components as it pertains to the intended use, essential performance, transport, storage conditions as part of the power supply The end-product evaluation shall ensure that the requirements related to Accompanying Documents, Clause 7.9 are met Fuse of Littelfuse, Type 392 does not have adequate breaking capacity 100A; Overcurrent releases of adequate breaking capacity must be employed in the end product. Additional Information Original 4787022260: upgrade standard to ANSI/AAMI ES60601-1 (2005 + C1:09 + A2:10 + A1:12) and CAN/CSA-C22.2 No. 60601-1 (2014). The product is certified previously by ANSI/AAMI ES60601-1: 2005 and CAN/CSA-C22.2 No.60601-1:08, 2 nd Edition, Refer to E182560-A101 for details. The risk management requirements of the standard were not addressed. Comparison previous report, Just modification to some minor information below : a. Changed all various to interchangeable in CCL. b. Changed all Astec or Artesyn or Emerson to Astec or Artesyn in CCL.

Issue Date: 2016-01-22 Page 5 of 9 Report Reference # E182560-V4-S48 Additional Standards The product fulfills the requirements of: N/A Clause Title Company identification Model Supply Connection Alternating current Marking or Instruction Details Classified or Recognized company's name, Trade name, Trademark or File Model number Voltage range, ac/dc, phases if more than single phase Supply Frequency Power Input Output Fuses Protective earth ground Rated frequency range in hertz Amps, VA, or Watts Rated output voltage, power, frequency. Ratings (current and voltage) and type. (located adjacent to fuse OR as a diagram inside enclosure) Special Instructions to UL Representative N/A Production-Line Testing Requirements Test Exemptions - The following models are exempt from the indicated test Model Grounding Continuity Dielectric Voltage Withstand LPS54-M N/A No exemption (refer to E182560-A101 for test voltage) Patient Circuit Dielectric Voltage Withstand Solid-State Component Test Exemptions - The following solid-state components may be disconnected from the remainder of the circuitry during either Dielectric Voltage Withstand Test: Component Sample and Test Specifics for Follow-Up Tests at UL The following tests shall be conducted in accordance with the Generic Inspection Instructions Plastic Enclosure or Part Test Sample(s) Test Specifics -- -- N/A

Issue Date: 2016-01-22 Page 6 of 9 Report Reference # E182560-V4-S48 TABLE: List of Critical Components Object/part or Description Manufacturer/ trademark type/model technical data CCN /Standard Marks of Conformity Marking plate 3M (MH16411) 7815 100 C, for application to Polycarbonate. PGJI2/8 UL969 UL/cUL Label Supplier Interchangeable Interchangeable Various PGAA UL PWB Interchangeable Interchangeable V-0 or Better, 130 C ZPMV2 / UL 796, UL UL94 Connector (SK1) MOLEX 5414 (Marked 7A, 250V ECBT2 UL 41791) UL1977 Alternate - Connector WECO A396-T-DS 10A, 300V ECBT2 UL (SK1) UL1977 Connector (SK2) Interchangeable Interchangeable 6 pins provided. QMFZ2 UL Plastic minimum V-1 or better. UL746C, UL94 Fuse (F1, F2) LITTELFUSE WICKMANN WERKE (E67006) 392 T3.15 AL, 250 V. Marked "F1 T3.15AL 250V" and "F2 T3.15AL 250V" on PWB respectively.50a breaking capacity JDYX2/8 UL248-14 UL/cUL Fuse (F1, F2)-Alternate Interchangeable Interchangeable Listed, T3.15 AL, 250 V ac. Marked "F1 T3.15AL 250V" and "F2 T3.15AL 250V" on PWB. Min. 100A breaking capacity. X-Cap. (C1) (optional) Interchangeable Interchangeable Min. 250 V, Max. 0.33 µf, Class X1 or Class X2, provided with VDE or SEV marking. Y-Cap (C2, C3) Interchangeable Interchangeable Max. 220 pf, Min. 250 V, Class Y1, provided with VDE or SEV marking. Electrolytic Capacitor (C5, C32) Bridge capacitor (C17) (Optional) Interchangeable Interchangeable 68 µf, minimum 400 V, minimum 105 C, provided with pressure relief. Interchangeable Interchangeable Max. 1000 pf, Min. 250 V, Class Y1, provided with VDE or SEV marking. JDYX/7 UL248-14 UL/cUL FOKY2/8, UL/cUL FOWX2/8 UL60384-14, IEC60384-14 FOKY2/8, UL/cUL FOWX2/8 UL60384-14, IEC60384-14 FOKY2/8, FOWX2/8 UL60384-14, IEC60384-14 Bridge Diode (DB1) Interchangeable Interchangeable Min 600 V, 4 A. UL/cUL

Issue Date: 2016-01-22 Page 7 of 9 Report Reference # E182560-V4-S48 Object/part or Description Manufacturer/ trademark type/model technical data CCN /Standard Marks of Conformity Transistor (Q5) Interchangeable Interchangeable Rated 500 V, 9 A. Discharging resistor (R4, Interchangeable Interchangeable Max 470 kohm, Min 1/4 W respectively. R5) Opto-coupler (IC2, IC3) Lite-On Technology LTV-817 Double Protection, Viso; 5300 V ac. FPQU2, FPQU8 UL/cUL Corp.(E113898) UL1577 Opto-coupler (IC2, IC3) - Vishay Infrared System code H Double Protection, Viso; 4420 Vac. FPQU2, FPQU8 UL/cUL Alternate Components or J UL1577 Transformer (T1) Astec or Artesyn Part No. 8527200060 or 801-004176- XXXX Class F(OBJY2), Astec, type 155-10C (E94225). See enclosure attachment for T1 spec. XORU3/9 UL/cUL Common Mode Choke (L1) Alternate-Common Mode Choke (L1) Astec or Artesyn Astec or Artesyn Part No. 85272000100 or 801-001965- XXXX Part No. 85272000380 Output Choke (L2) Astec or Artesyn Part No. 85220101330 or 801-004191- XXXX Common Mode Choke (L3) Alternate-Common Mode Choke (L3) Astec or Artesyn Astec or Artesyn Part No. 85272000110 or 801-001966- XXXX Part No. 85272000090 130 C, Consists of (OBMW2), copper magnet wire wound toroidal ferrite core and bobbin, (QMFZ2), Chang Chun Plastic, type T375J, V-0, min. 0.79 mm thick. Secured on PWB by soldering. 130 C, Consists of (OBMW2), copper magnet wire wound toroidal ferrite core and bobbin, (QMFZ2), Chang Chun Plastic, type T375J, V-0, min. 0.79 mm thick. Secured on PWB by soldering. 130 C, Secondary location. Enameled copper wire wound on cylindrical ferrite core. 130 C, Consists of (OBMW2), copper magnet wire wound toroidal ferrite core and stand-base, (QMFZ2), Chang Chun Plastic, type T375J, V-0, min.0.79 mm thick. Secured on PWB by soldering. 130 C, Consists of (OBMW2), copper magnet wire wound toroidal ferrite core and stand-base, (QMFZ2), Chang Chun Plastic, type T375J, V-0, min.0.79 mm thick. Secured on PWB by soldering. Primary heat sink (Q5) Interchangeable Interchangeable Metal, L-shaped, overall approximately 55.5 by 8.5 mm by 20.5 mm, 1.0 mm thick Secondary heat sink Interchangeable Interchangeable Metal, L-shaped, overall approximately 65.0 mm

Issue Date: 2016-01-22 Page 8 of 9 Report Reference # E182560-V4-S48 Object/part or Description (D2) Manufacturer/ trademark type/model technical data CCN /Standard Marks of Conformity by 32.5 by 22.0 by 32.5 mm., 1.0 mm thick.

Issue Date: 2016-01-22 Page 9 of 9 Report Reference # E182560-V4-S48 Enclosures Type Supplement Id Description Photographs Fig.3-01 Overall View 01 Photographs Fig.3-02 Bottom View Photographs Fig.3-03 Overall View 02 (Label shown) Diagrams ILL.4-01 T1 Spec Diagrams ILL.4-02 L1 Spec Diagrams ILL.4-03 L2 Spec Diagrams ILL.4-04 L3 Spec Diagrams ILL.4-05 L1 Spec (852-7200380) Diagrams ILL.4-06 L3 Spec (852-7200090) Schematics+PWB ILL.5-01 PCB layout of main board Manuals ILL.6-01 Operating Instruction Miscellaneous ILL.7-01 Label Artwork Miscellaneous ILL.7-02 Client Declaration