Getting Started StyliCleaner v Getting started:

Similar documents
QIAcube HT Unpacking and Installation Instructions

QTFX-LF900 Low-Level Fog Machine User Manual

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

FQ30-T FRYER COMMISSION AND DEMONSTRATION FORM 8700 LINE AVENUE SHREVEPORT, LA (800) Date

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Cleaning the internal optics surfaces

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Installing ProSeries software for stand-alone use

FULLY AUTOMATIC A/C SERVICE UNIT USE AND INSTRUCTION MANUAL

Installation & Calibration Guide

Advanced Laundry Chemical Dosing System for Single and Multi-Washers

SCAN200E USER S MANUAL

Installing ProSeries 2005

Manual. Snow machine S-2

rvm4c Installation Guide Remote Video Module

Manual v1 Page 1 of 19. Manual. Laboratory autoclave

PumpLab TM Operator s Manual

AUTOMATIC TROLLEY UNIT FOR RECOVERY, RECYCLING, VACUUM AND CHARGE

Routine Outdoor Helium Compressor Maintenance Instructions

73 Series Spectrophotometer. Accessory fitting and operation manual

KHM800 Professional 800w haze machine

SERVICE MANUAL REFRIGERATED AIR DRYER DIGI-PRO CONTROLLER WARRANTY NOTICE

Alarm System Example

AIR CONDITIONER PERFORMANCE RATING

Programat EP Operating Instructions

COOKBOOK for. > A reference guide for all GTX Series users >>> <<<

Digital Marine Exhaust Temperature Alarm

, '0''/).''$ /*'( 1'%* 00) ',))% *)) $ 3:36;$ !"## $%& '()*+,,,( '()*

Service instructions. Combi Steamer ASDE-B. energy. FlexiCombi MagicPilot

AIR-CONDITIONING SERVICE COMPRESSOR REPLACEMENT AND FLUSHING THE AIRCONDITIONING SYSTEM

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Avigilon Control Center 5 System Integration Guide

AUTOMATIC TROLLEY UNIT FOR RECOVERY, RECYCLING, VACUUM AND CHARGE

Marcus Schütte (Product Management) Sebastian Prühl (R&D) Competitive Analysis Sterisart Universal Pump Symbio

Guide to the Art Robbins Gryphon (and Phoenix) Crystallization Robot at UAB (CBSE)

MacDonald Steel Limited

flexibility programmed settings.

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger

Fully automatic air conditioning service! Bosch ACS 600, 601 and 650 for the workshop

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Ambient Temperature/ Relative Humidity & Dew Point Temperature Sensors to USB Output. Model LFS108B

STEMSEL Beginners Project 1: Alarm System

Manual. Fazer DFZ-800

Solar Cascade Solar Duo Cascade Solar Fish

INSTALLATION MANUAL. FlexFuison PLATINUM ELECTRIC COMBI FPE-615 FPE-621 FPE-115 FPE-121 FPE-215 FPE-221

MXT ROTARY RACK OVEN SET UP AND OPERATION INSTRUCTIONS (With programming instructions)

Instruction Manual Machine P/N: # & #

N-Wissen GmbH. Top Loading Autoclaves (95, 120, 135 L) Available top loading models: The Top Loading Autoclave range features:

Installation & operating manual. Swimming pool water. UV disinfection device UV10+

Standard Operating Manual

Davis Soil Moisture and Temperature Station Protocol

Millennium Xtra. Millennium ATMA setup and configuration guide. May Millennium Group, Inc.

TV2 Room Pressure Monitor Quick Start Guide

Jetstream Series HPLC - PELTIER COLUMN-THERMOSTATS 1. GENERALITIES

BRS Mechanically-Agitated BioReactor MA 100. Quick Reference Guide Ver2.0

MIX Boiler & Font Range Service Manual

Before you install ProSeries Express Edition software for network use

User Manual. GPD 3000 e. gas detector

THERMOSYS 4.3. Getting Started Guide

Combi Steamer Read this manual before using. Convotherm 4 easytouch. Operating Instructions USA Original, ENG. Your meal. Our mission.

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1

Static Pressure Control

User Manual. Melting Point Excellence System MP70/MP80/MP90

Step 1 - Install ProSeries Basic software

D-TECT 3 IP. GJD260 IP Motion Detector

Setting up Homebase, Exporting and Importing time clock files into OptRight Online

SINGLE SERVING AUTOMATIC POD MACHINE FKP-4T NEWCO ENTERPRISES INC, 3650 NEW TOWN BLVD SAINT CHARLES, MO FAX

Alarm Client. Installation and User Guide. NEC NEC Corporation. May 2009 NDA-30364, Revision 9

IMBALLAGGI P.K. s.a.s. Via Campegi, 87/89, I VIGEVANO PV tel telefax

CIRCO 6 Solar Circulation Unit

UF424 and UN324. Technical Service

INSTALLATION, OPERATION and MAINTENANCE MANUAL for Cres Cor RADIANT OVENS

Wacker Neuson Instruction Guide: Revision 6

IMR 5000 IMR 400. CEMS Operating Manual IMR USA S/N: Sample IMR Sensors Inside IMR 400. Gas Dryer Inside. IMR Environmental Equipment Inc.

Technical Information. Kröber O2

Driven by CLIMATISATION. Excellence for professionals. Bosch air conditioning service units for R-134a and R-1234yf

AIR OPERATED CLUTCH & BRAKE BLEEDING KIT. MODEL NO: CHT637 Part No: OPERATING & MAINTENANCE INSTRUCTIONS GC01/12

Evans Waterless Engine Coolant. General Installation Instructions.

1. Lenel Job Aid: Logging into Lenel RDS. Logging into the Lenel RDS webpage

Moisture Induced Sensitivity Test. MIST Operation Guide. Innovators In Instrumentation Technology

Oakton TEMP 9500 Advanced Multiparameter Controller

Model: LD5 Dual Mode Refrigerant Gas Leak Detector. Operating Instructions

Welcome to ProSeries Express Edition tax software

MultiSite Manager. Setup Guide

INSTRUCTIONS. Family 4 N 4062 Issue C Date 01/2011. CMV Certification reference NF205.

Bravo. Troubleshooting Guide

YELLOW JACKET. H 2 Tracer Gas Leak Detector. Operations Manual. Detects 5% H 2 in 95% Nitrogen Tracer Gas. Model 69341

Installing ProSeries 2004

JOVY SYSTEMS RE User Manual Rev. 1.00

WL User Manual. Innovative Technology for a Connected World. global solutions: local support TM

GLOBAL. InstallatIon & operation manual

Chapter 6. Alarm History Screen. Otasuke GP-EX! Chapter 6 Alarm History Screen 6-0. Alarm History Screen 6-1. Display Alarm History in List 6-2

JOVY SYSTEMS RE-7500 User Manual Rev Index

ASWRB100 ASWRB300 USE & CARE GUIDE

SW-2 SNOW MACHINE. Item ref: UK User Manual

ALLERGEN MIXING ASSISTANT

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

THERMO BUTTON HYGRO BUTTON The smallest temperature and humidity loggers in the world!

HX-900 Recirculating Chiller

USER MANUAL USB Multi-Function Datalogger Model RHT35

Transcription:

Getting started:

Introduction This presentation describes how a StyliCleaner should be put into use. Follow all future instructions. All these instructions are also described in the manuals supplied.

Contents of the packaging The following parts are included in the plastic box of the StyliCleaner: 1) Control unit 2) Cleaning unit 3) Manuals 4) CE-Declaration 5) Power supply 6) T-piece for compressed air supply 7) Spare O-rings 8) Socket screw 9) Compresses air hose

Control unit Place the control unit on the back of the measuring machine. Attention!!! Make sure that the compressed air hose between the control unit and the cleaning unit is as short as possible. As a result, there is a little chance that there is still cleaning liquid in the hose after performing a cleaning.

Installation control unit using "plateholder" A special "plateholder" is also available for a Crysta-CMM with which the control unit can be hung underneath the flat plate. This holder is not suitable for other measuring machines such as the STRATO and a Euro-C.

Installation cleaning unit Place the control unit on the back of the measuring machine. This is "usually" placed under the parking position of the measuring machine. This allows the compressed air hose Ø4mm between control unit and cleaning unit to be as short as possible.

Connection cleaning unit Connect the cleaning unit to the control unit. 1) Connect the black cable to the cleaning unit 2) Compressed air hose Ø4mm cleaning unit 3) Compressed air hose Ø4mm control unit

Connection power supply Connect the power supply to the control unit Pay attention!!! Do not plug the power supply into an outlet. We will only do this when the entire StyliCleaner is connected. There are also 2 additional connection adapters for the power supply. Use this if necessary.

Cleaning liquid Fill the reservoir of the nebuliser with a cleaning liquid. Never use heptane for this (this will eventually damage various parts). Use (if possible) refill bottles with pipette (if possible). Unscrew the gray screw and fill the liquid through the opening. Fill the tank maximum by 75% and screw the gray screw back on.

Spare parts O-rings 2 spare O-rings are supplied with the StyliCleaner. You can use these O-rings if the O-ring breaks when the cleaning liquid is being refilled.

Connecting compressed air The supply of compressed air must be connected to "clean" compressed air. Therefore place the T-piece behind the air filters that are placed near the measuring machine. 1) First shut off the compressed air supply 2) Place the T-piece behind the air filters 3) Place the compressed air hose Ø6mm on the T-piece 4) Place the compressed air hose Ø6mm on the control unit 5) Put compressed air on the system

Insert power supply into the socket Finally, plug the power supply into a power outlet. We now have successively: a) The control unit is placed on the CMM b) The cleaning unit is placed on the CMM and connected c) Reservoir filled with the cleaning fluid d) Compressed air on the system The last thing to do now is to install the programs to use the StyliCleaner in practice.

Installation program_1 1) Insert the USB-Stick into the computer 2) Start the explorer 3) Start the file in the map..\manual Mitutoyo\. 4) After pressing the button, all necessary files are extracted in the map C:\MCOSMOS\DATA\. 5) Enter the password Mako for unpacking.

Installation program_2 6) Go with the explorer to the folder C:\MCOSMOS\DATA\. We see that in this folder a map of StyliCleaner has now been placed Do not change the C:\MOSMOS\DATA\ folder. 7) Start the PartManager. 8) Make use of the button Change part directory to activate the folder to C:\MCOSMOS\DATA\StyliCleaner\.

Installation program_3 9) Start the measurement program 1 Setup StyliCleaner and follow all the steps described in the "Mitutoyo Handbook". 10) The next step is to measure the cleaning unit. Start program "2 Align StyliCleaner". The cleaning unit is always measured with the tree 1. 11) Measure 1 measuring point on the top of the cleaning unit.

Installation program_4 12) Measure a circle with 4 measuring points on the inside of the cleaning unit. 13) A message appears that when the probe is too close to the photocell, air is blown through the StyliCleaner. Press

Installation program_5 14) Finally measure a line at the front of the cleaning unit. 15) Subsequently, the inside diameter of the cleaning unit is automatically measured once again. At the end of the survey, the measuring machine moves to the parking position. The cleaning unit is now measured and can be used by Sub Programs. Leave the repeat function.

SubProgram Cleaning Performing the probe cleaning can be performed using a Sub Program. The SubProgram Cleaning to be used is located in the library of the parts list "C: \ MCOSMOS \ DATA \ StyliCleaner \". To start this Subprogram from all folders, we need to copy this Subprogram to the LibDir of MCOSMOS. Follow the steps in the "Manual Mitutoyo". SubProgram manager PartDir SubProgram manager LibDir

Perform a probe cleaning A probe cleaning can only be performed from the Repeat function. A probe cleaning can be programmed in the learning function. There is however the chance that a collision takes place during cleaning. This error message of the collision will be automatically canceled in the repetition function. How do we start a probe cleaning: Start a SubProgram "Cleaning" from the PartDirectory (preferably from the Library).

Extra action concerning settings long part names When using part lists with long names, the part list of the StyliCleaner has to be converted to long names. Start from menu the option and follow all steps. Then we see, that the layout changes for long names. Now we can start the SubProgram Cleaning from the LibDir.

Sample program cleaning tree 1234 Could be an example for cleaning tree 1+2+3+4:

Example program calibration Tree 1 + 2 including cleaning An example for calibrating and cleaning Tree1 + 2 could be:

Finaly By using the StyliCleaner we can fully automatically remove "light pollution" from the probe. Stubborn dirt is not removed. We therefore always have to carry out the removal of stubborn dirt manually. Never use heptane as a cleaning liquid. Heptane affects the parts of the StyliCleaner. Only when starting the probe cleaning in the repeat function, any "collisions" are automatically removed. When starting cleaning in the learning function, errors can occur.