Submittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18

Similar documents
Thank you for selecting LENNOX air conditioners.

Change for Life. Service Manual

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Change for Life. Service Manual GREE ELECTRIC APPLIANCES,INC.OF ZHUHAI

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

Specifications. (Model) KSIB009-H /2500 (W) 10600/9000(Btu/h) 13000/9500(Btu/h) 1250/ / SEER 16 HSPF 9.

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

AIR CONDITIONING SYSTEMS WALL MOUNTED UNIT

Klimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE

Part Ⅰ : Technical Information

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

TECHNICAL GUIDE MODELS: DCPM/DHPM PREMIUM SERIES DUCTLESS SINGLE-SPLIT AIR CONDITIONERS AND HEAT PUMPS 22 SEER 1 PHASE 3/4 THRU 3 NOMINAL TONS

Service Manual "P" SERIES 30K - 36K 220V INVERTER-DRIVEN AIR CONDITIONING UNITS IMPORTANT:

Service Manual. Models WAH48115MB WAH412230MB WH48YMB WH412ZMB

Samsung 360 Cassette, Single Zone, Split System

13 SEER CONDENSING UNITS & AIR HANDLERS

CASSETTE, FLOOR&CEILING, DUCT UNITS OUTDOOR UNITS

SERVICE MANUAL. Split Air Conditioner Arctic Series mod. A

Service Manual. Model: ACZEM4C4R18/ACZCI4C4R18 ACZEM4H4R18/ACZCI4H4R18 ACZEM4C4R24/ACZCI4C4R24 ACZEM4H4R24/ACZCI4H4R24 (Refrigerant:R410A)

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

GWH09QB-K3DNC6D GWH12QB-K3DNA1D GWH12QB-K3DNA2D GWH12QB-K3DNA3D GWH12QB-K3DNA6D GWH12QB-K3DNB2D GWH12QB-K3DNB4D GWH12QB-K3DNB6D GWH12QB-K3DNB8D

UCV CONDENSING UNITS SPECIFICATIONS 1. Specifications

Service Manual. Models WAH418230MB WH418ZMB WAH424230MB WH424ZMB

Product Data Split System (R-410A) Air Handler for Multi Split Inverter System 9,000 to 24,000 BTU/Hr

2017 LINE UP MINI SPLITS CATALOG

[U] Serie MOV. Manual de Ingeniería


Ductless Split Systems Concealed Duct Heat Pumps

InverterFlex SerIeS InverterFlex Systems condition up to five rooms

2014 Equipment Catalog

InverterFlex SERIES InverterFlex Systems condition up to five rooms

Mini-Split Single-Zone and Multi-Zone Air Conditioners and Heat Pumps. Residential Catalog 2018

MHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet

ductless mini-splits light commercial and multi-zone systems product catalog ALEGRIA ALEGRIA

Ductless Split Systems Ceiling Cassette Heat Pumps

DUCTLESS MINI-SPLITS LIGHT COMMERCIAL AND MULTI-ZONE SYSTEMS PRODUCT CATALOG ALEGRIA ALEGRIA SERIES ALEGRIA

DC Inverter Multi-split System Technical Manual - 50Hz/R410a

Submittal Data Sheet

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Service Manual & Installation Manual

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

SERVICE MANUAL. Room Air Conditioner Split Wall-Mounted Type. Models:

Residential and Light Commercial Ductless Systems Catalog

Market District Commons. Black Oak Engineering. Daikin Ductless Heat Pump Split Systems N/A N/A M001. Plans. Fujitsu ductless heat pump systems

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

DESIGN & TECHNICAL MANUAL

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

Technical Guide. Split Air-Conditioners Equipment Residential COS Series

Multi Inverter Air Conditioning Condensing Units - Summary

Change for life. Service Manual GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI

TECHNICAL GUIDE MODELS: DCMF/DHMF LX SERIES DUCTLESS SINGLE-SPLIT AIR CONDITIONERS AND HEAT PUMPS 16 SEER 1 PHASE 3/4 THRU 2 NOMINAL TONS DESCRIPTION

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

DUCTLESS MINI-SPLITS SINGLE-ZONE HYPERTEK MULTI-ZONE

THE WORLD S MOST EFFICIENT HEAT PUMP

Project ID: 9217 Project name: Fuller Lake Arena Address: Fuller Lake, BC V0R 1K5 Project Type: Sports Complex / Civic Center

2017 LINE UP MINI SPLITS CATALOG

Service Manual "X" SERIES 18K - 24K - 208/230V INVERTER-DRIVEN AIR CONDITIONING UNITS PLEASE READ AND UNDERSTAND THIS MANUAL BEFORE USING THIS

PERFORMANCE SERIES Single Zone & Multi-Zone Ductless Systems

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

DESHUMIDIFIER MH-V5 Service manual

Change for Life. Service Manual. Models: MULTI18HP230V1BO MULTI24HP230V1BO GREE ELECTRIC APPLIANCES,INC.OF ZHUHAI

Air Conditioner Service Manual

GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI

GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

Product Data INDUSTRY LEADING FEATURES / BENEFITS

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

2018 Equipment Catalog

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Specifications and Performance S2H

Mini-Split and Multi-Zone Air Conditioners and Heat Pumps. Residential/Light Commercial Catalog 2016

MINI-SPLITS SINGLE-ZONE HYPERTEK MULTI-ZONE

Commercial High-Efficiency Condensing Units

DESIGN & TECHNICAL MANUAL

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

A single answer for multiple zones.

A single answer for multiple zones.

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

AIR CONDITIONERS SPLIT TROPICAL RANGE. FLAT SPLIT - Heat & Cool T1 R410a AMD K BTU EAN: AMD K BTU EAN:

1. Product Lineup. 2. External Appearance. 3. Nomenclature M R C 36 H W N1 - R. Power supply R: 380~415V 3Ph~ 50Hz. Refrigerant type N1: R410A

Commercial High-Efficiency Condensing Units

1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA...

SKM. Air Conditioners TROPICAL

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

Transcription:

Submittal Sheet Submitted for: Approval Record Job Name: Contractor: Engineer: Date: Location: Tag: AIR-CON MULTI-SPLIT II Indoor Units Outdoor Unit High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18 A16EW4H4R09 AMTCM4H4R24 A16EW4H4R12 A16EC4H4R12 A16EK4H4R12 A16EL4H4R12 AMTCM4H4R30 A16EW4H4R18 A16EC4H4R18 A16EK4H4R18 A16EL4H4R18 AMTCM4H4R36 A16EC4H4R24 A16EK4H4R24 A16EL4H4R24 AMTCM4H4R42 Notes:

Summary, Features, and Construction Views Indoor Units A16EW4H4R09 A16EW4H4R12 A16EW4H4R18 09 & 12K Indoor Units Wall Bracket: 18K Indoor Unit Wall Bracket: Unit: mm Model W H D Q R S A16EW4H4R09 848 275 180 135 540 173 A16EW4H4R12 A16EW4H4R18 940 298 200 108 694 138 Unit: Inches A16EW4H4R09 33-3/8 10-7/8 7-3/32 5-5/16 21-1/4 6-13/16 A16EW4H4R12 A16EW4H4R18 37 11-3/4 7-7/8 4-1/4 27-11/32 5-7/16 *True dimensions in mm, dimensions in inches have been approximated to the nearest 32th of an inch

Summary, Features, and Construction Views Remote Controller YB1FAF(XFAN) 1 ON/OFF-Press to Start/Stop Operation 2 MODE-Press to select operation mode (AUTO/COOL/DRY/FAN/HEAT) 3 + Press to increase temperature setting 4 - Press to decrease temperature setting 5 FAN-Press to set fan speed 6 Press to set swing angle 7 TIMER ON-Press to set timer on 10 11 1 2 4 3 5 6 9 7 8 8 TIMER OFF-Press to set timer off 9 CLOCK-Press to set clock 10 X-FAN-(X-FAN is the alternative expression of BLOW for the purpose of understanding) 11 TEMP 12 TURBO 13 SLEEP 14 LIGHT-Press to turn on or off controller backlight 12 13 14

Specifications Specifications Indoor Unit High-Wall Type Parameter Unit Value Model A16EW4H4R09 A16EW4H4R12 A16EW4H4R18 Product Type High-Wall High-Wall High-Wall Rated Voltage V~ 208/230 208/230 208/230 Rated Frequency Hz 60 60 60 Power Supply Mode Outdoor Outdoor Outdoor Cooling Capacity Btu/h 9000 12000 18000 Heating Capacity Btu/h 9800 13000 19800 Air Flow Volume m 3 /h 560/500/430/370/- 580/470/430/370/- 850/780/650/550/- (SH/H/M/L/SL) CFM 329/294/253/217/- 341/276/253/217/- 500/459/382/323/- Dehumidifying L/h 0.8 1.4 1.8 Volume Application Area m 2 12-18 16-24 23-24 ft 2 129-193 172-258 247-258 Fan Type Cross-flow Cross-flow Cross-flow Diameter Length mm Φ92X645 Φ92X645 Φ98X710 (DXL) in Φ3.6X25.4 Φ3.6X25.4 Φ 3.8X27.9 Fan Motor Cooling r/min 1260/1100/950/750/- 1280/1100/950/750/- 1350/1200/1050/900/- Speed (SH/H/M/L/SL) Fan Motor Heating r/min 1320/1200/1100/950/- 1300/1170/1050/950/- 1420/1250/1150/1050/- Speed (SH/H/M/L/SL) Output of Fan Motor W 20 20 20 Fan Motor RLA A 0.2 0.2 0.25 Evaporator Form Aluminum Fin-copper Tube Aluminum Fin-copper Tube Aluminum Fin-copper Tube Pipe Diameter mm Φ7 Φ7 Φ7 in Φ0.27 Φ0.27 Φ0.27 Row-fin Gap mm 2-1.4 2-1.4 2-1.4 in 0.078-0.055 0.078-0.055 0.078-0.055 Coil Length (LXDXW) mm 645X25.4X267 645X25.4X267 715X25.4X304.8 in 25.4X1.0X10.5 25.4X1.0X10.5 28.1X1X12 Swing Motor Model MP24AA MP24AA MP28VB Output of Swing W 2.4 2.4 2 Motor Fuse A 3.15 3.15 3.15 Sound Pressure db(a) 41/37/35/26/- 42/38/36/26/- 46/44/40/35/- Level (SH/H/M/L/SL) Sound Power Level (SH/H/M/L/SL) db(a) 51/47/45/36/- 52/48/46/36/- 56/54/50/45/-

Dimension (WXHXD) mm 848X275X180 848X275X180 940X298X200 in 33.4X10.8X7.0 33.4X10.8X7.0 37.0X11.7X7.8 Dimension of Carton mm 915X255X355 915X255X355 1010X285X380 Box (LXWXH) in 36.0X10.0X13.9 36.0X10.0X13.9 39.8X11.2X14.9 Dimension of mm 918X258X370 918X258X370 1013X288X395 Package (LXWXH) In 36.1X10.1X14.5 36.1X10.1X14.5 39.9X11.3X15.5 Net Weight kg 10 10 13 Lbs 22 22 28.7 Gross Weight kg 13 13 17 Lbs 28.7 28.7 37.5

Indoor Units Cassette A16EC4H4R12 A16EC4H4R18 A16EC4H4R24 Unit: mm Model W H A A16EC4H4R12 570 230 650 A16EC4H4R18 570 230 650 A16EC4H4R24 840 240 950 Unit: Inches A16EC4H4R12 10.6 9.1 25.6 A16EC4H4R18 10.6 9.1 25.6 A16EC4H4R24 33.1 9.45 37.4

Indoor Unit Cassette Type Parameter Unit Value Model A16EC4H4R12 A16EC4H4R18 A16EC4H4R24 Product Type Cassette Cassette Cassette Rated Voltage V~ 208/230 208/230 208/230 Rated Frequency Hz 60 60 60 Phases 1 1 1 Cross-sectional Power AWG18 AWG18 AWG18 Cable Recommended Power Cable 4-Core Stranded Copper Wire 4-Core Stranded Copper Wire 4-Core Stranded Copper Wire Fuse Current A 3.15 3.15 3.15 Cooling Capacity Btu/h 12000 14400 22800 Heating Capacity Btu/h 13000 16000 27400 Air Flow Volume (SH/H/M/L/SL) m 3 /h 600/500/450 600/500/450 /1180//950/850/ CFM 353/294/265 353/294/265 /694//559/500/ Dehumidifying Volume L/h 1.4 1.80 2.50 Pint/h 2.96 3.80 5.28 Application Area m 2 16-24 19-29 30-46 ft 2 172-258 206-310 326-490 Fan Type Centrifugal Centrifugal Centrifugal Fan Quantity 1 1 1 Diameter-Height (DXL) mm Φ283-148 Φ283-148 Φ450-112 in Φ11.14-5.83 Φ11.14-5.83 Φ17.7-4.4 Fan Motor Model FN11T-2 FN11T-2 FN35B-1 Fan Motor Drive Type Direct Drive Direct Drive Direct Drive Fan Motor Speed (SH/H/M/L/SL) r/min 845/700/600 845/700/600 620/570/520 Standard Static Pressure InWg 0.00 0.00 0.00 psig 0.00 0.00 0.00 Output of Fan Motor W 11 11 50 Input of Fan Motor W 50 50 100 Fan Motor RLA A 0.23 0.23 0.43 Fan Motor Capacitor μf 1 1 3 Motor Full Load Amp A 0.18 0.18 0.43 (FLA) Evaporator Material Inner Groove Copper-Aluminum Inner Groove Copper-Aluminum Inner Groove Copper- Aluminum Pipe Diameter mm Φ9.52 Φ9.52 Φ7 in Φ3/8 Φ3/8 Φ0.2756 Evaporator Face Area m 2 0.19 0.19 0.35 in 2 294 294 543 Evaporator Number of Rows 2 2 3

Evap. Tube Pitch (a) X mm 25.4X19.05 25.4X19.05 19.05X12.07 Row Pitch (b) in 1X3/4 1X3/4 3/4X0.475 Evaporator Fin Type Hydrophilic filmlouver fin Hydrophilic filmlouver fin Hydrophilic film-louver fin Evaporator Fin Color Blue Blue Blue Evap. Dimensions mm 956.1X203.2X38.1 956.1X203.2X38.1 2040.8X171.5X30 (LXHXW) in 37.6X8X1.5 37.6X8X1.5 80.35X6.75X1.18 Evap. Max Allowable MPa 4.0 4.0 4.3 Pressure PSI 580 580 623 Air Filter Size mm 344.5X333.5/1 344.5X333.5/1 543X542/1 (LXW/No.) in 13-5/16 X13-1/8 /1 13-5/16 X13-1/8 /1 21.38X21.34/1 Drain Connection mm Φ31 Φ31 Φ31 (Outer Diameter) in Φ1.22 Φ1.22 Φ1.22 Sound Pressure Level db(a) //46/44/42 //46/44/42 /39//37//35/ (SH/H/M/L/SL) Sound Power Level db(a) //56/54/52 //56/54/52 /49//47//45/ (SH/H/M/L/SL) Gas Pipe (to IDU) mm Φ9.52 Φ12.7 Φ15.9 in Φ3/8 Φ1/2 Φ5/8 Liquid Pipe (to IDU) mm Φ6.35 Φ6.35 Φ9.52 in Φ1/4 Φ1/4 Φ3/8 Connection Method Flare Connection Flare Connection Flare Connection Dimension (WXDXH) mm 570X570X230 570X570X230 840X840X240 in 10.6X10.6X9.1 10.6X10.6X9.1 33.1X33.1X9.45 Dimension of Carton mm 848X728X310 848X728X310 960X960X310 Box (LXWXH) in 33.4X28.7X12.2 33.4X28.7X12.2 37.8X37.8X12.2 Dimension of Package mm 851X731X325 851X731X325 963X963X325 (LXWXH) In 33.5X28.8X12.8 33.5X28.8X12.8 37.1X37.1X12.8 Net Weight kg 18 18 28 Lbs 40 40 62 Gross Weight kg 23 23 35 Lbs 51 51 77 Panel Outline mm 650X650X50 650X650X50 950X950X60 Dimension (WXDXH) in 25.6X25.6X2 25.6X25.6X2 37.4X37.4X2.4 Panel Dimensions of mm 730X670X102 730X670X102 1040X1025X115 Carton (WxDxH) in 28.7X26.4X4 28.7X26.4X4 40.9X40.4X4.5 Panel Package Dimension (LXWXH) mm 733X673X117 733X673X117 1043X1028X130 In 28.9X26.5X4.6 28.9X26.5X4.6 41.1X40.5X5.1 Panel Net Weight kg 2.50 2.50 6.5 Lbs 5.5 5.5 14.3 Panel Gross Weight kg 3.65 3.65 10 Lbs 8.1 8.1 22.1

Duct Type A16EK4H4R12 A16EK4H4R18 A16EK4H4R24 Unit: mm Model W D H A16EK4H4R12 700 615 200 A16EK4H4R18 900 615 200 A16EK4H4R24 1100 615 200 Unit: Inches A16EK4H4R12 27.56 24.21 7.87 A16EK4H4R18 35.4 24.21 7.87 A16EK4H4R24 43.3 24.21 7.87

Indoor Unit Duct Type Parameter Unit Value Model A16EK4H4R12 A16EK4H4R18 A16EK4H4R24 Product Type Duct Type Duct Type Duct Type Rated Voltage V~ 208/230 208/230 208/230 Rated Frequency Hz 60 60 60 Phases 1 1 1 Cross-sectional Power Cable AWG18 AWG18 AWG18 Recommended Power Cable 4-Core Stranded Copper Wire 4-Core Stranded Copper Wire Fuse Current A 3.15 3.15 3.15 Cooling Capacity Btu/h 11900 15300 23800 Heating Capacity Btu/h 13100 18700 27400 Air Flow Volume (SH/H/M/L/SL) 4-Core Stranded Copper Wire m 3 /h /550/400/300/ /700/600/500/ /1000/750/550/ CFM /324/235.4/177/ /411.95/353.1/294.25/ /588.5/441.4/323.7 Dehumidifying Volume L/h 1.4 1.80 2.5 Pint/h 2.96 3.80 5.28 Application Area m 2 15.9-23.8 23.9-35.7 31.8-47.6 ft 2 171-256 257-384 342-512 Fan Type Centrifugal Centrifugal Centrifugal Fan Quantity 2 3 4 Diameter-Height (DXL) mm Φ139.45- Φ139.45-134.62 Φ139.45-134.62 134.62 in Φ5.5-5.3 Φ5.5-5.3 Φ5.5-5.3 Fan Motor Model FG40A FG60A FG20E Fan Motor Drive Type Direct Drive Direct Drive Direct Drive Fan Motor Speed r/min 960/830/700 920/780/720 985/800/680 (SH/H/M/L/SL) Output of Fan Motor W 49 75 22.5 Input of Fan Motor W 80 100 124 Fan Motor RLA A 0.35 0.43 0.54 Fan Motor Capacitor μf 3 3 3 Motor Full Load Amp (FLA) A 0.31 0.41 0.50 Evaporator Material Inner Groove Copper- Aluminum Inner Groove Copper- Aluminum Pipe Diameter mm Φ7 Φ7 Φ7 in Φ0.275 Φ0.275 Φ0.275 Evaporator Face Area m 2 0.11 0.15 0.19 in 2 170 232 295 Evaporator Number of Rows 3 3 3 Evap. Tube Pitch (a) X Row Pitch (b) Inner Groove Copper-Aluminum mm 19.05X12.7 19.05X12.7 19.05X12.7 in 3/4X1/2 3/4X1/2 3/4X1/2

Evaporator Fin Type Hydrophilic filmlouver fin Hydrophilic film-louver fin Hydrophilic filmlouver fin Evaporator Fin Color Blue Blue Blue Evap. Dimensions (LXHXW) mm 527X209.55X25 725X209.55X38.1 925X209.55X38.1.4 in 20.75X8.25X1 28.5X8.25X1.5 36.4X8.25X1.5 Evap. Max Allowable MPa 4.3 4.3 4.3 Pressure PSI 623 623 623 Air Filter Size (LXW/No.) mm 601.5X197.4/1 802X193/1 1002.6X196.5/1 in 23.7X7.77/1 31.57X7.6/1 39.5X7.75/1 Drain Connection (Outer mm 26 26 26 Diameter) in 1.02 1.02 1.02 Sound Pressure Level db(a) /39/35/32/ /47/37/33/ /42/38/34/ (SH/H/M/L/SL) Sound Power Level db(a) /49/45/42/ /51/47/43/ /52/48/44/ (SH/H/M/L/SL) Gas Pipe (to IDU) mm Φ9.52 Φ12.7 Φ15.9 in Φ3/8 Φ1/2 Φ5/8 Liquid Pipe (to IDU) mm Φ6.35 Φ6.35 Φ9.52 in Φ1/4 Φ1/4 Φ3/8 Connection Method Flare Flare Connection Flare Connection Connection Dimension (WXDXH) mm 700X615X200 900X615X200 1100X615X200 in 27.56X24.21X7. 35.4X24.2X7.9 43.3X24.2X7.9 87 Dimension of Carton Box mm 890X740X290 1120X740X290 1320X740X290 (LXWXH) in 35X30X11.8 44X29.1X11.4 51.9X29.1X11.4 Dimension of Package (LXWXH) mm 893X743X305 1123X743X305 1323X743X305 in 37X31X12.6 44.2X29.25X12 52X29.25X12 Net Weight kg 23 27 31 Lbs 51 60 68 Gross Weight kg 29 36 41 Lbs 64 79 90

Floor and Ceiling Type A16EL4H4R12 A16EL4H4R18 A16EL4H4R24 Unit: mm Model W D H A16EL4H4R12 1220 225 700 A16EL4H4R18 1220 225 700 A16EL4H4R24 1220 225 700 Unit: Inches A16EL4H4R12 48 8.9 27.6 A16EL4H4R18 48 8.9 27.6 A16EL4H4R24 48 8.9 27.6

Indoor Unit Floor and Ceiling Type Parameter Unit Value Model A16EL4H4R12 A16EL4H4R18 A16EL4H4R24 Product Type Floor and Ceiling Floor and Ceiling Floor and Ceiling Rated Voltage V~ 208/230 208/230 208/230 Rated Frequency Hz 60 60 60 Phases 1 1 1 Cross-sectional Power Cable AWG18 AWG18 AWG18 Recommended Power Cable 4-Core Stranded Copper Wire 4-Core Stranded Copper Wire 4-Core Stranded Copper Wire Fuse Current A 3.15 3.15 3.15 Cooling Capacity Btu/h 11900 17000 22800 Heating Capacity Btu/h 13100 18700 27400 Air Flow Volume (SH/H/M/L/SL) m 3 /h /650/550/450/ /950/700/500/ /1250/900/700/ CFM /383/324/265 /559/412/294 /736/530/412/ Dehumidifying Volume L/h 1.40 1.80 2.50 Pint/h 2.96 3.80 5.28 Application Area m 2 15.9-23.8 23.9-35.7 31.8-47.6 ft 2 171-256 257-384 342-512 Fan Type Centrifugal Centrifugal Centrifugal Fan Quantity 4 4 4 Diameter-Height (DXL) mm Φ139.5-104.8 Φ139.5-104.8 Φ139.5-104.8 in Φ5.5-4.125 Φ5.5-4.125 Φ5.5-4.125 Fan Motor Model FG10A FG20E FG50A Fan Motor Drive Type Direct Drive Direct Drive Direct Drive Fan Motor Speed (SH/H/M/L/SL) r/min /690/610/480/ /985/800/680/ /985/800/680/ Output of Fan Motor W 15 20 40 Input of Fan Motor W 55 110 145 Fan Motor RLA A 0.28 0.56 0.63 Fan Motor Capacitor μf 1 2.5 2 Motor Full Load Amp (FLA) A 0.3 0.5 0.5 Evaporator Material Inner Groove Copper-Aluminum Inner Groove Copper-Aluminum Inner Groove Copper-Aluminum Pipe Diameter mm Φ7 Φ7 Φ7 in Φ0.275 Φ0.275 Φ0.275 Evaporator Face Area m 2 0.24 0.28 0.28 in 2 372 434 434 Evaporator Number of Rows 2 3 3 Evap. Tube Pitch (a) X Row Pitch (b) mm 19.05X12.7 19.05X12.7 19.05X12.7 in 3/4X1/2 3/4X1/2 3/4X1/2

Evaporator Fin Type Hydrophilic filmlouver fin Hydrophilic filmlouver fin Hydrophilic filmlouver fin Evaporator Fin Color Blue Blue Blue Evap. Dimensions (LXHXW) mm 804.9X304.8X25.4 920X304.8X50.8 920X304.8X50.8 in 31.7X12X1 36.2X12X2 36.2X12X2 Evap. Max Allowable Pressure MPa 4.3 4.3 4.3 PSI 623 623 623 Air Filter Size (LXW/No.) mm 554X220.5/2 554X220.5/2 554X220.5/2 in 21.8X8.7/2 21.8X8.7/2 21.8X8.7/2 Drain Connection (Outer mm Φ17 Φ17 Φ17 Diameter) in Φ0.67 Φ0.67 Φ0.67 Sound Pressure Level db(a) /40/38/36/ /45/42/40/ /48/46/44/ (SH/H/M/L/SL) Sound Power Level db(a) /50/48/46/ /55/52/50/ /58/56/54/ (SH/H/M/L/SL) Gas Pipe (to IDU) mm Φ9.52 Φ12.7 Φ15.9 in Φ3/8 Φ1/2 Φ5/8 Liquid Pipe (to IDU) mm Φ6.35 Φ6.35 Φ9.52 in Φ1/4 Φ1/4 Φ3/8 Connection Method Flare Connection Flare Connection Flare Connection Dimension (WXHXD) mm 1220X700X225 1220X700X225 1220X700X225 in 48X27.6X8.9 48X27.6X8.9 48X27.6X8.9 Dimension of Carton Box (LXHXW) mm 1340X820X300 1340X820X300 1340X820X300 in 52.75X32.3X11.8 52.75X32.3X11.8 52.75X32.3X11.8 Dimension of Package (LXHXW) mm 1343X823X315 1343X823X315 1343X823X315 in 52.9X32.4X12.4 52.9X32.4X12.4 52.9X32.4X12.4 Net Weight kg 40 40 45 Lbs 88 88 99 Gross Weight kg 50 50 54 Lbs 110 110 119

Summary, Features, and Construction Views Outdoor Unit AMTCM4H4R18, AMTCM4H4R24, AMTCM4H4R30 AMTCM4H4R30 & AMTCM4H4R36 AMTCM4H4R42

Unit: mm Model W H D O P R S AMTCM4H4R18 965 700 498 341 892 559 368 AMTCM4H4R24 980 790 440 341 892 559 368 AMTCM4H4R30 976 787 440 370 920 559 400 AMTCM4H4R36 1080 1103 440 362 1016 630 376 AMTCM4H4R42 1068 1093 432 356 1016 611 383 Unit: Inches AMTCM4H4R18 38 27-9/16 19-39/64 13-27/64 35-1/8 22 14-1/2 AMTCM4H4R24 38-37/64 31-7/64 17-21/64 13-27/64 35-1/8 22 14-1/2 AMTCM4H4R30 38-27/64 31 17-21/64 14-37/64 36-7/32 24 15-23/32 AMTCM4H4R36 42-1/2 43-27/64 17-21/64 14-1/4 40 24-13/16 14-51/64 AMTCM4H4R42 42-1/32 43-1/64 17-1/64 14-1/64 40 24-1/16 15-1/16 *True dimensions in mm, dimensions in inches have been approximated to the nearest 32th of an inch

Outdoor Unit Parameter Unit Value Model AMTCM4H4R18 AMTCM4H4R24 Product Code CB228W07700 CB228W07800 Power Supply Rated Voltage V~ 208/230 208/230 Rated Frequency Hz 60 60 Phases 1 1 Power Supply Mode Outdoor Outdoor Power Cable AWG14 3 Core AWG12 3 Core Circuit Breaker A 25 30 Cooling Capacity (Min~Max) Btu/h 18000(6998~21001) 24000(7500~33000) Heating Capacity (Min~Max) Btu/h 19000(7000~22600) 26000(7500~35000) Cooling Power Input W 1440 1920 Heating Power Input W 1520 2050 Rate Power Input W 2800 4550 Cooling Current Input A 6.26 8.35 Heating Current Input A 6.61 8.90 Rated Current Input A 12.42 20.19 Starting Current A 5 5 EER W/W 3.66 3.66 (Btu/h)/W 12.50 12.50 COP W/W 3.66 3.72 (Btu/h)/W 12.50 12.70 SEER 22 21 HSPF 10.5 10.50 Outdoor Unit Compressor Manufacturer Zhuhai Landa Compressor Co. Zhuhai Landa Compressor Co. Compressor Model QXA-B141zF030A QXAS-D23zX090B Compressor Oil RB68EP RB68EP Compressor Oil Charge L 0.39 0.95 Compressor Type Inverter Rotary Inverter Rotary L.R.A. A / / Compressor RLA A 10.82 15.82 Compressor Power Input W 1440 2550 Overload Protector 1NT11L-6233 1NT11L-6233 Electrical Heater Power W 96+/-5% 160+/-5% Input Throttling Method Electronic Expansion Valve Electronic Expansion Valve Ambient Temperature C -18~48-18~48 (Cooling) F 0~118 0~118 Ambient Temperature C -20~24-20~24 (Heating) F -4~75-4~75 Condenser Form Aluminum Fincopper Tube Aluminum Fincopper Tube Max Drive IDU 2 3

Pipe diameter (Gas) IU 1 mm Φ9.52 Φ9.52 in Φ3/8 Φ3/8 Pipe diameter (Gas) IU 2 mm Φ9.52 Φ9.52 in Φ3/8 Φ3/8 Pipe diameter (Gas) IU 3 mm - Φ9.52 in - Φ3/8 Pipe diameter (Liquid) IU mm Φ6.35 Φ6.35 1 in Φ1/4 Φ1/4 Pipe diameter (Liquid) IU mm Φ6.35 Φ6.35 2 in Φ1/4 Φ1/4 Pipe diameter (Liquid) IU 3 mm - Φ6.35 in - Φ1/4 Fan Motor Model LW60M-ZL LW92K-ZL Fan Motor Speed RPM 630 800 Output of Fan Motor W 60 90 Fan Motor Capacitor μf / 3.5 Air Flow Volume of Outdoor Unit m 3 /h 3200 4000 CFM 1883 2354 Fan Type Axial-Flow Axial-flow Fan Diameter-height mm Φ520-58 Φ550-66 in Φ20.5-2 ¼ Φ21.7-2.62 Defrosting Method Automatic Defrosting Automatic Defrosting Climate Type T1 T1 Isolation I I Moisture Protection IPX4 IPX4 Permissible Excessive Operating Pressure for the Discharge Side Permissible Excessive Operating Pressure for the Suction Side Sound Pressure Level (H/M/L) Sound Power Level (H/M/L) MPa 4.3 4.3 PSI 623 625 MPa 2.5 2.5 PSI 362 365 db(a) 56/-/- 59/-/- db(a) 63/-/- 69/-/- Dimension (WXHXD) mm 955X700X396 980X790X427 in 37.6X27.6X15.6 38.6X31.1X16.8 Dimension of Carton Box mm 1026X455X735 1080X485X840 (L/W/H) in 40.4X17.9X28.9 42.5X19.1X33.1 Dimension of Package mm 1029X458X750 1083X488X855 (L/W/H) in 40.5X18.0X29.5 42.6X19.2X33.7 Net Weight kg 52 69.5 Lbs 115 153 Gross Weight kg 56.5 74.5 Lbs 125 164 Refrigerant R410A R410A

Connection Pipe Refrigerant Charge kg 1.6 2.2 Lbs 3.5 4.85 Not Additional Gas m 10 30 Length ft 32.8 98 Gas Additional Charge g/m 20 20 Oz/ft 0.215 0.215 Max Distance Height m 10 10 (indoor to indoor) ft 32.8 33 Max Distance Height m 10 10 (indoor to outdoor with indoor up) ft 32.8 32.8 Max Distance Height m 10 10 (indoor to outdoor with outdoor up) ft 32.8 32.8 Max. Equivalent pipe m 10 20 length (outdoor to last indoor) ft 32.8 65 Max Distance Length (total) m 20 60 ft 65.6 197 Parameter Unit Value Model AMTCM4H4R30 AMTCM4H4R36 AMTCM4H4R42 Product Code CB228W07900 CB228W08000 CN860W0180 Power Supply Rated Voltage V~ 208/230 208/230 208/230 Rated Frequency Hz 60 60 60 Phases 1 1 1 Power Supply Mode Outdoor Outdoor Outdoor Power Cable AWG12 3 Core AWG12 3 Core AWG10 3 Core Circuit Breaker A 30 35 40 Cooling Capacity (Min~Max) Btu/h 28400(8189~33438) 34000(8871~35826) 39000(8871~40944) Heating Capacity (Min~Max) Btu/h 30000(8189~32414) 42500(8871~44356) 45004(8871~46062) Cooling Power Input W 2270 2720 3740 Heating Power Input W 2350 3370 3650 Rate Power Input W 3800 3800 4000 Cooling Current Input A 9.87 11.84 16.5 Heating Current Input A 10.22 14.64 16 Rated Current Input A 16.86 16.86 / Starting Current A / / / EER W/W 3.66 3.66 3.06 (Btu/h)/W 12.50 12.50 10.43 COP W/W 3.74 3.70 3.61 (Btu/h)/W 12.76 12.62 12.33 SEER 21 21 21 HSPF 10.5 10.50 10.2

Outdoor Unit Compressor Manufacturer Zhuhai Landa Compressor Co. Zhuhai Landa Compressor Co. Zhuhai Landa Compressor Co. Compressor QXAS-D32zX090A QXAS-D32zX090A QXAS-D32zX090A Model Compressor FV50S FV50S FV50S Oil Compressor L 1 1 1 Oil Charge Compressor Inverter Rotary Inverter Rotary Inverter Rotary Type L.R.A. A / / / Compressor A 13.9 15.6 17.8 RLA Compressor W 4150 4150 4150 Power Input Overload 1NT11L-6233 1NT11L-6233 1NT11L-6233 Protector Electrical W 96+/-5% 96+/-5% 96+/-5% Heater Power Input Throttling Method Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve Ambient C -18~48-18~48-18~48 Temperature (Cooling) F 0~118 0~118 0~118 Ambient Temperature (Heating) Condenser Form C -20~30-20~30-20~30 F -4~86-4~86-4~86 Aluminum Fincopper Tube Aluminum Fincopper Tube Max Drive IDU 4 5 5 Pipe diameter mm Φ9.52 Φ9.52 Φ9.52 (Gas) IU 1 in Φ3/8 Φ3/8 Φ3/8 Pipe diameter mm Φ9.52 Φ9.52 Φ9.52 (Gas) IU 2 in Φ3/8 Φ3/8 Φ3/8 Pipe diameter mm Φ9.52 Φ9.52 Φ9.52 (Gas) IU 3 in Φ3/8 Φ3/8 Φ3/8 Pipe diameter mm Φ9.52 Φ9.52 Φ9.52 (Gas) IU 4 in Φ3/8 Φ3/8 Φ3/8 Pipe diameter mm - Φ9.52 Φ9.52 (Gas) IU 5 in - Φ3/8 Φ3/8 Pipe diameter mm Φ6.35 Φ6.35 Φ6.35 (Liquid) IU 1 in Φ1/4 Φ1/4 Φ1/4 Pipe diameter mm Φ6.35 Φ6.35 Φ6.35 (Liquid) IU 2 in Φ1/4 Φ1/4 Φ1/4 Pipe diameter mm Φ6.35 Φ6.35 Φ6.35 (Liquid) IU 3 in Φ1/4 Φ1/4 Φ1/4 Aluminum Fincopper Tube

Pipe diameter (Liquid) IU 4 Pipe diameter (Liquid) IU 5 Fan Motor Model Fan Motor Speed Output of Fan Motor Fan Motor Capacitor Air Flow Volume of Outdoor Unit mm Φ6.35 Φ6.35 Φ6.35 in Φ1/4 Φ1/4 Φ1/4 mm - Φ6.35 Φ6.35 in - Φ1/4 Φ1/4 SWZ150A SWZ150B SWZ150B RPM 850 880 880 W 100 170 170 μf / / / m 3 /h 4000 7700 7700 CFM 2354 4531 4531 Fan Type Axial-Flow Axial-flow Axial-flow Fan Diameterheight mm Φ550-120 Φ570-152 Φ570-152 in Φ21.7-4.75 Φ22.4-6 Φ22.4-6 Defrosting Method Automatic Defrosting Automatic Defrosting Automatic Defrosting Climate Type T1 T1 T1 Isolation I I I Moisture IPX4 IPX4 IP44 Protection Permissible MPa 4.2 4.2 4.2 Excessive Operating Pressure for the Discharge Side PSI 609 609 609 Permissible Excessive Operating Pressure for the Suction Side Sound Pressure Level (H/M/L) Sound Power Level (H/M/L) Dimension (WXHXD) Dimension of Carton Box (L/W/H) Dimension of Package MPa 2.5 2.5 2.5 PSI 363 363 363 db(a) 59/-/- 61/-/- 61/-/- db(a) 69/-/- 71/-/- 71/-/- mm 980X790X427 1087X1103X440 1087X1103X440 in 38.6X31.1X16.8 42.8X43.4X17.3 42.8X43.4X17.3 mm 1080X485X840 1155X480X1115 1155X480X1115 in 42.5X19.1X33.1 45.5X18.9X43.9 45.5X18.9X43.9 mm 1083X488X855 1158X493X1235 1158X493X1235 in 42.6X19.2X33.7 45.6X19.4X48.6 45.6X19.4X48.6

Connection Pipe (L/W/H) Net Weight kg 70 90 90 Lbs 154 198 198 Gross Weight kg 77 98 98 Lbs 170 216 216 Refrigerant R410A R410A R410A Refrigerant kg 2.8 3.65 3.65 Charge Lbs 6.2 8 8 Not Additional m 40 40 40 Gas Length ft 131 131 131 Gas Additional g/m 20 20 20 Charge Oz/ft 0.215 0.215 0.215 Max Distance Height (indoor to indoor) Max Distance Height (indoor to outdoor with indoor up) Max Distance Height (indoor to outdoor with outdoor up) Max. Equivalent pipe length (outdoor to last indoor) Max Distance Length (total) m 7.5 7.5 7.5 ft 24.6 24.6 24.6 m 15 15 15 ft 49.2 49.2 49.2 m 15 15 15 ft 49.2 49.2 49.2 m 25 25 25 ft 82 82 82 m 70 75 75 ft 230 246 246

Certified Units Combinations Outdoor Unit AHRI Certified Ref. Indoor Unit Cooling Capacity Heating Capacity (Btuh @ 47 F) EER SEER HSPF 10149864 Non-Ducted Indoor Units 18000 19000 12.5 22 11 AMTCM4H4R18 10149865 Ducted Indoor Units 18000 19000 11.5 16 8.5 10149866 Mixed (Ducted & Non-Ducted) 18000 19000 12 19 9.75 10149867 Non-Ducted Indoor Units 24000 26000 12.5 21 11 AMTCM4H4R24 10149868 Ducted Indoor Units 24000 26000 10.5 16 8.5 10149869 Mixed (Ducted & Non-Ducted) 24000 26000 11.5 18.5 9.75 10149870 Non-Ducted Indoor Units 28400 30000 12.5 21 11.5 AMTCM4H4R30 10149871 Ducted Indoor Units 28400 30000 10.5 16 8.5 10149872 Mixed (Ducted & Non-Ducted) 28400 30000 11.5 18.5 10 10149873 Non-Ducted Indoor Units 34000 42500 12.5 21 11.5 AMTCM4H4R36 10149874 Ducted Indoor Units 34000 42500 11.5 16 8.5 10149875 Mixed (Ducted & Non-Ducted) 34000 42500 12 18.5 10 10149876 Non-Ducted Indoor Units 39000 45000 10.4 21 10.2 AMTCM4H4R42 10149877 Ducted Indoor Units 39500 46500 9.8 14.7 9.6 10149878 Mixed (Ducted & Non-Ducted) 39250 45750 10.1 17.85 9.9