WRF04 CO 2 RS485 Modbus

Similar documents
WRF04 CO2. Application. Types Available. Security Advice Caution. Combined room sensor CO 2 / temperature / humidity. Datasheet

FTW04. Application. Types Available. Security Advice Caution. Surface mounting room sensor for relative humidity and temperature.

FTK+ Application. Types Available. Duct sensor for humidity and temperature. Datasheet

LCF Touch (from firmware version 1.7)

LCF Touch Modbus Datasheet Application Security Advice Caution

LCF Touch. Electronic Fan Coil Thermostat with Touch Display (Flush mounting) Datasheet. Application. Security Advice Caution.

Air Quality. Sample applications 243 CO2 VOC CO2+VOC. Air Quality

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date:

Room air quality sensors

Technical Instructions Document No. CE1N1961 March 17, Room CO 2 and Air Quality Sensors. Description. Features. Application

RSMFM-2R MULTIFUNCTIONAL

Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature

Wallace & Tiernan Controllers & Analysers ChemTrim Disinfection Controller

esense CO2 Transmitter and Alarm

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

DMFPM-2R MULTIFUNCTIONAL

Multifunction IAQ Monitor

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

The product can be worked together with our wireless controller to control a ventilator, air cleaning device, or

Recalibrate the way you look at gas detection

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

PROCESS ANALYSERS. SERVOFLEX MiniMP (5200) Gas Analyser. Operator Manual. Part Number: A Revision: 8 Language: UK English

CO2 transmitters TRANSMITTERS TO DETECT CARBON DIOXIDE (CO 2 )

User's Guide. CO 2 Monitor. Model CO200

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

KANE-ALERT-CO 2 Monitor with Temperature

CHILLGARD M-100. Refrigerant Sensor. Operating Manual. Order No.: /02

Datasheet: K-22 LO Sensor

Room Air Quality Sensors

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

Minimal maintenance requirements - No consumables and low cost of ownership. Rapid, accurate results - for safe operation of coal handling systems

Controllers, Indicators & Set Point Programmers

Model D12-IR. Digital Gas Transmitter...

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

CDL 210. Operating manual. CO2 Logger. Best.-Nr

Duct and Rough Service Carbon Monoxide Sensor

SENTRY-MS Mono-static Multi-gas Open Path Analyzer

DiMM Unit. LST Digital Interface Monitor Module (LST-DiMM) MAN3109

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

HPLC Column Ovens and Temperature Controllers

Ventostat Wall Mount. Amphenol. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Advanced Sensors. Features:

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

Duct Air Quality Sensors

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

WALLACE & TIERNAN CONTROLLERS & ANALYSERS CHEMTRIM DISINFECTION CONTROLLER PRODUCT SHEET

Light & Motion. Sample applications 259. Ceiling sensors. Wall sensors. Outdoor sensors. Motion. Light &

QPM21 Series Duct CO 2 and Air Quality Sensors

Danfoss gas detection units

Sensor unit MC2 with analog output for Freon gases and refrigerants

R9900. Model. Instruction Manual. Indoor Air Quality Meter. reedinstruments. www. com

SIL 2. Ultima X Series Gas Monitors CERTIFIED

User Manual R1.0 CO2Meter, Inc. Personal CO2 Monitor SAN-10

Instruction Manual CHHC-1

Semi flush-mount room thermostats

TDU Series LCD Thermostat For EFCB and EVCB Controllers. Models. Features. Functions. Onboard Sensors. Model # Temp RH CO2 Color.

EL-USB-1-LCD Temperature Data Logger with LCD

M-Sens 2. Online-Moisture Meter for Solids. Operating Instructions. SWR engineering Messtechnik GmbH

EC 350 PTZ Gas Volume Correctors Enabling Precision Gas Measurement

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

Installation and user manual

Two-Channel Gas Controller

Allure EC-Smart-Air Series Communicating sensors

Installation Manual. esense Duct (Disp) Figure 1 The esense Duct with and without display

M-Sens 2. Online moisture measurement for solids. Operating Instructions. SWR engineering Messtechnik GmbH PART OF THE ENVEA GROUP

EL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface

Connected Industrial. EC 350 PTZ GAS VOLUME CORRECTORS ENABLING PRECISION GAS MEASUREMENT Proven Technology. Superior Performance.

TLS 500. Installation and Operation Manual. English Pages CEDES AG is certified according to ISO 9001: V 1.1.

TOXIC GAS AND OXYGEN DETECTOR DTX 420 INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS DTX420_MAN01_EN_V1R2

AIRFLOW MEASUREMENT AND CONTROL PRODUCT CATALOG. Phone: 877-4GNTROL ( ) - Internet: GreenTrol.com. r1f

DGS - Danfoss Gas Sensor Check / Calibration Procedure

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

Air Quality Sensors. Particle Matter, CO 2, Humidity, Temperature and Dust Products. OEM Sensor Components for Air Quality and Environmental Control

Instruction Sheet. Press & Hold: Item, to view settings, to test. 24 V ±10% 50/60 Hz 3 VA 120 V (ac) 5 A 1/6 hp pilot 240 VA 20 to 260 V (ac) 2 VA

Toxic Gas Detection. Model F12. Toxic Gas Detection

Danfoss gas detection units

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

Carbon Monoxide CO Transmitter ADT-X3-1110

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

TLS 600. Installation and Operation Manual. English Pages CEDES AG is certified according to ISO 9001: V 1.0.

Dräger Polytron Pulsar 2 Open Path Gas Detector

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

Key Features. General Description

Contents. Outline of Product. Features of Product. Specifications of Product. Name and central function of section. Illustration of Terminal

Water Technologies. V600 Disinfection Controller

Constant climate chamber with ICH-compliant illumination

LC1350 Level Controller

85 Uncompensated SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage

Installation Manual Tracker 221

BC3250. Blowdown Controller

Bacnet Room Setpoint & Temp Display. Descriptions. Specifications

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

Transcription:

WRF04 CO 2 RS485 Modbus Combined room sensor CO 2 / temperature / humidity Datasheet Subject to technical alteration Issue date: 26.02.2016 Application Surface mounted sensor for detection of CO2, temperature and optional relative humidity in room and office spaces. For direct connection to a DDC or a monitoring system, using 0..10 V outputs. Also available with traffic light LED and LCD display. Types Available WRF04 CO2 RS485 Modbus CO2, temperature WRF04 CO2 rh RS485 Modbus CO2, temperature, relative humidity Optional WRF04 CO2 xx LCD LCD for displaying measuring values TLF 3 LEDs for displaying level of CO 2 concentration Security Advice Caution The installation and assembly of electrical equipment should only be performed by authorized personnel. The product should only be used for the intended application. Unauthorised modifications are prohibited! The product must not be used in relation with any equipment that in case of a failure may threaten, directly or indirectly, human health or life or result in danger to human beings, animals or assets. Ensure all power is disconnected before installing. Do not connect to live/operating equipment. Please comply with Local laws, health & safety regulations, technical standards and regulations Condition of the device at the time of installation, to ensure safe installation This data sheet and installation manual

Page 2 / 6 Issue date: 26.02.2016 Notes on Disposal As a component of a large-scale fixed installation, Thermokon products are intended to be used permanently as part of a building or a structure at a pre-defined and dedicated location, hence the Waste Electrical and Electronic Act (WEEE) is not applicable. However, most of the products may contain valuable materials that should be recycled and not disposed of as domestic waste. Please note the relevant regulations for local disposal. Remarks to Room Sensors Location and Accuracy of Room Sensors The room sensor should be mounted in a suitable location for measuring accurate room temperature. The accuracy of the temperature measurement also depends directly on the temperature dynamics of the wall. It is important, that the back plate is completely flush to the wall so that the circulation of air occurs through the vents in the cover. Otherwise, deviations in temperature measurement will occur due to uncontrolled air circulation. Also the temperature sensor should not be covered by furniture or similar devices. Mounting next to doors (due to draught) or windows (due to colder outside wall) should be avoided. The temperature dynamics of the wall will influence the temperature measurement. Various wall types (brick, concrete, dividing and hollow brickwork) all have different behaviours with regards to thermal variations. Surface and Flush Mounting The temperature dynamics of the wall influence the measurement result of the sensor. Various wall types (brick, concrete, dividing and hollow brickwork) have different behaviours with regard to thermal variations. A solid concrete wall responds to thermal fluctuations within a room in a much slower way than a light-weight structure wall. Room temperature sensors installed in flush boxes have a longer response time to thermal variations. In extreme cases they detect the radiant heat of the wall even if the air temperature in the room is lower for example. The quicker the dynamics of the wall (temperature acceptance of the wall) or the longer the selected inquiry interval of the temperature sensor is the smaller the deviations limited in time are. Build-up of Self-Heating by Electrical Dissipative Power Temperature sensors with electronic components always have a dissipative power, which affects the temperature measurement of the ambient air. The dissipation in active temperature sensors shows a linear increase with rising operating voltage. This dissipative power has to be considered when measuring temperature. In case of a fixed operating voltage (±0,2 V) this is normally done by adding or reducing a constant offset value. As Thermokon transducers work with a variable operating voltage, only one operating voltage can be taken into consideration, for reasons of production engineering. Transducers 0..10 V / 4..20 ma have a standard setting at an operating voltage of 24 V =. That means, that at this voltage, the expected measuring error of the output signal will be the least. For other operating voltages, the offset error will be increased by a changing power loss of the sensor electronics. If a re-calibration should become necessary later directly on the sensor, this can be done by means of a trimming potentiometer on the sensor board. Remark: Occurring draft leads to a better carrying-off of dissipative power at the sensor. Thus temporally limited fluctuations might occur upon temperature measurement. Application Notice for Humidity Sensors Refrain from touching the sensitive humidity sensor/element. Touching the sensitive surface will void warranty. For standard environmental conditions re-calibration is recommended once a year to maintain the specified accuracy. When exposed to high ambient temperature and/or high levels of humidity or presence of aggressive gases (i.e. chlorine, ozone, and ammonia) the sensor element may be affected and re-calibration may be required sooner than specified. Re-calibration and deterioration of the humidity sensor due to environmental conditions are not subject of the general warranty. Information about Indoor Air Quality CO 2 EN 13779 defines several classes for indoor air quality: Category CO 2 content above the content in outdoor air in ppm Description Typical range Standard value IDA1 <400 ppm 350 ppm Good indoor air quality IDA2 400.. 600 ppm 500 ppm Standard indoor air quality IDA3 600..1.000 ppm 800 ppm Moderate indoor air quality IDA4 >1.000 ppm 1.200 ppm Poor indoor air quality Information about Self-Calibration Feature CO 2

Issue date: 26.02.2016 Page 3 / 6 All gas sensors are subject to drift caused by components. This fact results generally in the need to recalibrate the sensors regularly. With dual channel technology Thermokon integrates automatic self-calibration for different fields of operation. In contrast to common used ABC-Logic sensors with self-calibration dual channel are suitable for applications operating 24 hours, 7 days a week as for example hospitals. Manual calibration is not necessary! Technical Data Measuring values CO2, temperature, humidity Network technology RS485 Modbus, RTU orr ASCII, half duplex baudrate 9.600, 19.200, 38.400 or 57.600 Power supply 15..24 V = (±10%) or 24 V~ (±10%) Power consumption max. 1,5 W (24 V = 3 VA (24 V =) Measuring range temperature 0..+50 C Measuring range humidity 0..100% rh non-condensing Measuring range CO2 0..2000 ppm Accuracy temperature ±1% of measuring range (typ. at 21 C) Accuracy humidity ±2% between 10..90% rh (typ. at 21 C) Accuracy CO2 ±75 ppm or 10% of measuring range (typ. at 21 C), whatever is greater Calibration self-calibration, dual channel Sensor NDIR (non-dispersive, infrared) Display LCD 29x12 mm, monochrome (optional) 3 LEDs showing air quality (traffic light function TLF ) (optional) Enclosure ASA, pure white Protection IP30 according to EN 60529 Cable entry breaking points top/bottom, entry on rear Connection electrical terminal block max. 1,5mm² Ambient condition 0..+50 C, max. 85% rh non-condensing Weight 90 g Mounting to be mounted flat onto the surface using adhesive foil or screws

Page 4 / 6 Issue date: 26.02.2016 Mounting Advices Make sure that the device is power-off, if you install it! The device can be installed on a smooth wall surface or a flush box. A representative location for room temperature without direct insolation should be selected for the device. The use of deep installation boxes is recommended due to increased storage capacity for the wires. Empty tubes have to be sealed to avoid air draught from the installation tube. (1) For wiring, the upper part of the base plate has to be removed. Base plate and upper part are connected via snap tab located in the middle of the enclosure bottom. (2) The installation of the base plate to the smooth wall surface can be done either by sticking using the enclosed adhesive film (A) as well as using plugs and screws. (3) Finally the device is clicked into the base plate. Connection plan

Issue date: 26.02.2016 Page 5 / 6 Note: Avoid laying the cable on the CO2 sensor, because this may damage the device and influence the measuring values. Clamp Function 9 Modbus B (-) 10 Modbus A (+) 11 GND/AC2 12 +Uv/AC1 Functions description Traffic light function (optional) The LEDs visualize the air quality 0..33% 0..750 ppm green LED flashing 34..66% 751..1250 ppm yellow LED flashing 67..100% 1251..2000 ppm red LED flashing Configuration RS485 Modbus Register Information about RS485 Modbus registers and the software documentation can be downloaded on our homepage: http://www.thermokon.de/en/products/air-quality/co2/wrf04-co2.html

Page 6 / 6 Issue date: 26.02.2016 Dimensions (mm) Accessories Raw plugs and screws (2 pcs. each) Item No.: 102209 Frame for surface mounting WRF04 Item No.: 111584 Ball stroke protection BS100 Item No.: 103312