Importance of Auditing/Reviewing Your Company s GADS Events

Similar documents
Annex A-8 CONCENTRATED SOLAR POWER UNITS INDEX TO SYSTEM/COMPONENT CAUSE CODES

Annex A-7 FOSSIL STEAM UNITS INDEX TO SYSTEM/COMPONENT CAUSE CODES

Appendix B Index to System/Component Cause Codes

Annex A-6 FLUIDIZED BED COMBUSTION UNITS INDEX TO SYSTEM/COMPONENT CAUSE CODES

ANNEX A-1 GEOTHERMAL UNITS INDEX TO SYSTEM/COMPONENT CAUSE CODES BOILER BALANCE OF PLANT STEAM TURBINE GENERATOR MISCELLANEOUS - GEOTHERMAL EXTERNAL

Appendix B3 System/Component Cause Codes

Appendix B9 Geothermal Unit Cause Codes

Appendix B2 System/Component Cause Codes

When you complete this module you will be able to: Describe various watertube boiler designs, including large generating units.

We are involved in the manufacturing of Magnetic Separators, Gravity Separator, Magnetic Equipment, Suspension Magnet, Ball Mill etc.

MILL IN SERVICE FIRST COAL FIRES AT MEDUPI

CONSIDERATIONS IN CONVERTING A DUAL SHELL OR A DUAL PRESSURE COAL FIRED PLANT CONDENSER INTO A COMBINED CYCLE PLANT CONDENSER

Document Code: 1 (13) Issuing date: Status:

COILS / INDUSTRIAL HEAT EXCHANGERS / NUCLEAR PRODUCTS

CHP-turbine room. CHP can capture almost EXTRACTED STEAM 20 PSI HIGH-PRESSURE STEAM 1250 PSI HEAT EXCHANGER HOT WATER SUPPLY F

Boiler Light-up. Kumar Rupesh Date: 03-Sep-13

CASE HISTORY#1 BAD COOLING TOWER GEARBOX? Barry T. Cease Cease Industrial Consulting (843)

Brown Hills College of Engineering & Technology

Turbine, Generator and Auxiliaries - Course 134 TURBINE START-UP

Boiler Basics. Design and operation

Renovation, Modernization and Life Time Extension Measures on Steam Turbines Sustainable Growth - Strategies for efficiency Increase

Plant Closure Workshop

MECHANICAL SCIENCE Module 2 Heat Exchangers

Kube Engineering. Industry Guide. Power Industry

Tuesday, 18 November Video Links. Oil Blow Through 13 November BLOW THROUGH ON BOILER UNIT 6 BEGINS.

Cold Weather Preparedness Plant Winterization Lessons Learned & Best Practices

Seabrook Station Condenser Tube Leaks. Jim Johnson Seabrook Station FSRUG 2017

Power Generation Application Guide

Unit Design Data. Fossil Steam

2x58 MW Coal Fired Power Plant at Mauritius

What to Expect from Your EtaPRO Investment

POWER Selecting Shell Side Design Temperature for Feedwater Heaters

Document Code: 1 (15) Issuing date: Status:

High-Quality Manufacturing The Flowserve Flow Control Division has manufacturing facilities around the globe, ensuring an efficient supply chain no ma

Steam Power Cycles Part II

Power Generation. Application Guide

Locations Include: Food & Beverage. Chemical. Waste Water Treatment. Pulp & Paper. Energy, Oil & Gas

WATER TUBE SOLID FUEL SERIES YOSHIMINE CO., LTD

Unit Design Data. Fossil Steam (Voluntary Reporting) Unit name: Location of unit (State): Energy Information Administration (EIA) Number:

Green Energy Engineering, Inc.

Experience In Motion. WXH and WXM Utility-Grade Multistage Ring Section Pumps

Analysis the effect of condenser pressure (vacuum) on efficiency and heat rate of steam turbine

CHAPTER 3 BASIC STEAM CYCLE

Chapter 11. Design of Other BOP

POWERENERGY

CHAPTER 2: PROPERTIES OF STEAM AND STEAM POWER

Chapter 10 VAPOR AND COMBINED POWER CYCLES

Understanding Site Hazards

Optimizing Strategy for Boiler Drum Level Control

Solution of I Mid Term Steam Engineering 6ME5A

Stavros Chrysanthou Madrid DynAMo Alarm Management Secrets to unlocking complete Operational Integrity

Silhouette. Feedwater Heater. Boiler Feedwater

Household devices, <-<>al breaker rolls, stone crusher, four early types of power devices.

AUTOMATION OF BOILERS USING LABVIEW

Derating of 75 MWe Pulverised Coal Fired Power Plant without HP Heaters in Service A Case Study

Foster Wheeler Condensers and Feedwater Heaters. High Quality Steam Components

Steam and Power Conversion System


Unit Design Data FLUIDIZED BED COMBUSTION (VOLUNTARY REPORTING)

Standard Maintenance Task List Sample

Week 13 Chapter 10 Vapor & Combined Power Cycles

LONGEVITY SOLUTIONS FEEDWATER HEATERS CONDENSERS HEAT EXCHANGERS PRESSURE VESSELS AIR PREHEATERS ISOLATION DAMPERS AFTERMARKET SERVICES AND PARTS

Technical instructions

SHELL AND TUBE HEAT EXCHANGERS FOR INDUSTRIAL ONCE-THROUGH COOLING SYSTEMS AND THE OCCURRENCE OF LEAKAGE

HP-M/HP-P Automatic pulverizing mill and pellet press

A FREAK INCIDENT OF A BED SUPERHEATER FAILURE

2017 FSRUG Thermal Performance Feedwater Heater Troubleshooting FSRUG FWH Troubleshooting 1

A Study of the Condenser in Nuclear Power Plants

CONTENTS. B. System Design and Performance Requirements

Protective Chemistry for Steam Boiler Wet Layup posted to DPS client area on:

DELOMATIC 400, DM-400 HYDRO

Find Condenser Tube Leaks with Ultrasound

Boiler Draft Equipment

Document Code: 1 (5) Issuing date: Status:

By: Prof K. M. Joshi,

LIQUID RING PUMPS FOR THE POWER INDUSTRY

Your Concentrated Solar Power Generation Partner

The equipment and materials shall be designed and constructed in accordance with the ASME code section I 2001 ED A02 and Chinese Standards.

Feed Water Heaters Performance Indicators and Characteristics on the 405MW Coal-Thermal Power Plant

NLR ELECTRIC MURRAY HYDRO PLANT NORTH LITTLE ROCK, ARKANSAS

31.05/ Unit-1

SECTION HEATING AND AIR CONDITIONING PIPING SYSTEMS. A. Provisions of Division 01 apply to this section. 1. Chilled Water System.

Name : Roll no. : Division : Date of commencement : Date of completion :

Custom Design TYPE CS

FLUIDIZED BED BOILERS

ECO-ANT21 Corporation

Heater Assembly replacement - A pictorial guide

Installation and Operation Manual

Boiler Steam Supply Piping Basics November 18, ) Q: What kind of condensate traps should be used on vacuum condensate return systems?

BASIL 6000 TUNNEL CAGE WASHER

Burner Management and Combustion Control. Copyright 2014 Rockwell Automation, Inc. All Rights Reserved.

MODULATING CONTROL OF LOW NO X BURNERS

SURGING AND BLOW OUT OF LOOP SEALS IN A CFBC BOILER. By K.K.Parthiban Venus energy audit system

PLACE FOR TITLE. Continuous Control of Lube Oil Water. Contamination Never get Surprised Again. Steve Locke. The Chemours Co.

GPPS-2017-Put 4 digit paper number here

Installation, Operation and Maintenance of Central Boiler Plants

BENSON Boilers Experience in Nearly 1000 Plants and Innovative Design Promise Continuing Success Manfred Klein, Rudolf Kral, Eberhard Wittchow

Thank You for Attending Today s Webinar:

Refrigerated Compressed Air Dryer

A Newsletter published by ESI. The Steam and Power SPECIAL FORCES

Transcription:

Importance of Auditing/Reviewing Your Company s GADS Events Leeth DePriest Chairman GADS Working Group (GADSWG) 1

Why Audit/Review Your Company s Events To meet the mandatory GADS reporting requirements To provide for consistent reporting in your company and throughout the industry To provide reliable data to compare your own units and to benchmark against the industry 2

This presentation addresses the importance of good descriptions and cause code choices 3

Many events in the industry are reported without descriptions, so How do I know the event type is correct? How do I know the cause code is correct? How do I know that my benchmarking results are correct if I compare my units to the industry? Most events (except RS) need a good description. A good GADS reporter should feel obligated to include the description. 4

What does a good, accurate description provide? Insight to know if the correct event type is selected (planned, maintenance, forced) Verification that the cause code is correct 5

What is necessary to properly review the events? Familiarity with the GADS cause codes and how they are organized Plant experience and high level of plant knowledge Ability to use plant historian to review events Willingness to challenge what is reported Support of your management 6

Examples of Poor Reporting The examples you are about to see are real. The names have been removed to protect the guilty. 7

Example 1 Original cause code: Air heater fouling (tubular) 1492 Description: Washing air heater New cause code: Air heater fouling (regenerative) 1493 Comments: Plant does not have tubular air heaters 8

Example 2 Original cause code: Transmission line (Powerhouse switchyard to 1 st substation) 3710 Description: Doble and power factor testing of GSU transformer New cause code: Main transformer 3620 Comments: Description describes transformer test 9

Example 3 Original cause code: Other combined cycle problems 6299 Description: Gas turbine tripped due to swing in IP drum level New cause code: Operator Error 9900 Comments: Many errors are reported as equipment problems 10

Example 4 Original cause code: Other high pressure turbine problems 4099 Description: Changed out a cracked expansion joint New cause code: Crossover and under piping 4270 Comments: Joint was on crossover from IP to LP turbine Question events listed as other 11

Example 5 Original cause code: Bearings HP turbine 4040 Description: Turbine vibration on #11 and #12 bearings New cause code: Generator vibration 4560 Comments: These bearings are on the generator 12

Example 6 Original cause code: Pulverizer inert system 0342 Description: A mill out to replace pyrite gate New cause code: Pulverizer pyrite removal system 0346 Comments: Description says it is a pyrite system problem 13

Example 7 Original cause code: Other main steam valves 0520 Description: Reduced load to repack superheat automatic spray water valve New cause code: Desuperheater/attemperator valves 0590 Comments: Need to be familiar with codes on minor equipment 14

Example 8 Original cause code: Other generator problems 4899 Description: Black start testing New cause code: Black start testing 9998 Comments: There is a specific code for the event 15

Example 9 Original cause code: Other hydro problems 7299 Description: Replacement of all wicket gate positioners New cause code: Wicket gate operating mechanism or positioner 7141 Comments: A diligent look at the codes would have found 7141 16

Example 10 Original cause code: Feedwater pump/drive lube oil system 3415 Description: F mill off to repair lube oil pump New cause code: Pulverizer lube oil system 0335 Comments: Both codes say lube oil. Oops! 17

Example 11 Original cause code: Primary air fan 0260 Description: Changed out 2A PA fan motor due to a bad bearing New cause code: Primary air fan drives 0263 Comments: Description clearly says motor 18

Example 12 Original cause code: First reheater slagging and fouling 1160 Description: Pinhole leak in panel 40 and panel 1 New cause code: First reheater tube leaks 1060 Comments: Both cause codes say first reheater 19

Example 13 Original cause code: Motors for low pressure pumps 2621 Description: Added oil to A reactor coolant pump motor New cause code: Reactor coolant/recirculating pump motor 2210 Comments: Description clearly defines the correct code 20

Example 14 Original cause code: Coal conveyors and feeders 0030 Description: B mill out to clean out conveyor New cause code: Pulverizer feeders 0250 Comments: Need good knowledge of plant equipment 21

Example 15 Original cause code: Pulverizer feeders 0250 Description: A mill out to inspect mill ball charge depth New cause code: Pulverizer mills 0310 Comments: This is obviously not a feeder problem 22

Example 16 Original cause code: Loss of vacuum not attributable to a particular component 3149 Description: Condenser vacuum was lost due to loss of seal water on vacuum pump (hole in seal water line) New cause code: Vacuum pump 3133 Comments: Component issue was clearly known 23

Example 17 Original cause code: Windbox expansion joints 0845 Description: Repair oil leak on B boiler feedwater pump New cause code: Feedwater pump/drive lube oil system 3415 Comments: What were they thinking? 24

Example 18 Original cause code: Loss of vacuum not attributable to a particular component 3149 Description: A crack developed in the hotwell allowing air in leakage New cause code: Hotwell 3123 Comments: Component issue was clearly known 25

Example 19 Original cause code: Other air heater fouling (heat pipe) 1495 Description: Air heater magnetic coupling failed New cause code: Air heater (regenerative) 1488 Comments: This plant does not have heat pipe air heaters and fouling was not the issue 26

What can we do to improve? Call your reporter when the description and cause code do not match. You may be surprised at what really happened. Familiarize your reporters with the codes Have plant knowledgeable reporters Have experienced reporters. Do not make GADS an after thought for your newest employee. 27