Now In Production JULY 2008

Similar documents
DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

Multi-Path RTU-TYPE 2

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

VariCool VAV Engineering Guide

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

Advance Release September 2009

VertiCool Aurora Engineering Guide

C13-Series Engineering Guide

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

RSG16**S1M. Split System Air Conditioner 16 SEER

High Heat COP. High/Low Stage

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

Air-Cooled Split System Condensing Units for Remote DX Coils and Air Handlers. Models RCS 015D to 140D R-410A Refrigerant.

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

36,000-62,000 BTUH Nominal Capacity

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT MBtuh

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

technical guide Water-Cooled Self-Contained Units

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

4YCC3048A3096A /3/ /

2YCC3060A1120A /1/ / YCC3060A1096A /1/ /

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Water-Cooled Self-Contained Units

CoolSpot Engineering Guide

Roof Top Packaged Unit (RTU-1) Specification

PRODUCT SPECIFICATIONS 2YCC3036A1096A /1/ /

Split System Heat Pumps

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

STANDARD EFFICIENCY PACKAGE A/C UNIT to 216 MBtuh

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps

SKYPAK II, 3 Ton Series, gives you a

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

Portable Vertical Air-Conditioning and Heating Systems

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

MACH N-407 Heat Pump Air-Cooled Chiller

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

Product Data /4WCC3018A through 2/4WCC3060A Single Package Convertible Heat Pump 13 SEER 1½ - 5 Ton R-22/R-410A

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

DCG Commercial. Submittal Data Form

Submittal Summary Page

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

R4H4. Product Specifications

ADDENDUM 1. Southeast High School Auditorium & Gymnasium HVAC Improvements

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers

WALL-MOUNT HEAT PUMPS - (60HZ)

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

PAR5. Product Specifications

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

ELECTRICAL QUANTITY WEIGHT (LB)

SKYPAK II, 3 Ton Series, gives you a

MAC N-407 Air-Cooled Chiller

General Description. Operation

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Condensing Units & Air Handlers

THE WALL-MOUNT TM SIX TON AIR CONDITIONER

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers

SUBMITTAL. Project. CLU Swenson Center. Date 01/07/2010. Mechanical Contractor. West Coast Air Conditioning. Mechanical Engineer

SUBMITTAL DATA SHEET FEATURES. SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15 & 20 TONS MODELS: NH-07 thru -20, 2-PIPE NJ-10 thru -20, 4-PIPE

50TM TFF COMBINATION HEATING/COOLING UNITS


EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

50TM COMBINATION HEATING/COOLING UNITS

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

48TM GAS HEATING/ELECTRIC COOLING UNITS

Worksheet for Small Commercial Air System Design

Product Data. GEMINI SELECT 09DPS ,09DPM Air-Cooled Condensers with PURON Refrigerant (R-410A) 50/60 Hz

Call us today! (800)

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

DSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER

48TF GAS HEATING/ ELECTRIC COOLING UNITS

SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG:

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

4YCC3036A1075B /1/ / YCC3036A1064B /1/ /

EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, Standard CFM / Ls EER

Transcription:

Now In Production JULY 2008 OptiSolar, McClellan, CA Nine (9) Custom new single-zone units with 135 tons of DX cooling, air cooled condensing sections and direct drive supply air blowers. Ambient design 102 deg F, total unit EER 11.5 Representative : EI Systems/Tempco, 555 Twin Dolphin Plaza S 630, Redwood City, CA 94065 Brain Mazur / Wais Jalali ; P 650-596-1700 ; F 650-596-1701 OptiSolar manufactures photovoltaic (PV) modules and products power from their own large-scale solar farms. OptiSolar engineers are require reliability, performance, and efficiency; and Seasons-4 is the manufacturer of their choice. Units consist of formed, welded and coated galvanized steel base, HCFC- free R-410A refrigerant, six (6) scroll compressors piped independently to 6 intertwined DX coils. Isolation dampers and walking grating are provided on supply and return air openings. Direct drive supply air blowers with shaft grounding kits, premium efficiency motors, 2 spring isolators with Zone-4 seismic tie downs, and direct drive propeller exhaust fans are some of the requirements of the project. 1

Now In Production JULY 2008 OptiSolar, McClellan, CA Nine (9) Custom new single-zone units with 135 tons of DX cooling, air cooled condensing sections and direct drive supply air blowers. Ambient design 102 deg F, total unit EER 11.5 Representative : EI Systems/Tempco, 555 Twin Dolphin Plaza S 630, Redwood City, CA 94065 Brain Mazur / Wais Jalali ; P 650-596-1700 ; F 650-596-1701 Painted interior liner, 12 cartridge filters, filter rack for future HEPA filters, magnehelic filter gauges with sun shields, photoelectric supply and return smoke detectors and ABB variable frequency drives on supply and exhaust fan motors are some of features provided for the units. Separate high voltage and low voltage conditioned control panels are required. Kynar painted aluminum exterior panels with single handle, multiple latches doors are additional features. The units are build in two sections to be rigged with a helicopter. 2

ENGINEERING SPECIFICATIONS JOB NAME LOCATION OPTI SOLAR MCCLELLAN, CA DATE PREPARED Revised: 07/29/08 SEASONS-4 REFERENCE # A167-01 UNIT MODEL # 3SST45-1356-XXXXX-45SE 14 UNIT DESIGNATION 03-HVAC-ACU-01C TO 03-HVAC-ACU-09C SYSTEM VOLTAGE 460/3/60 18 DESIGN DATA TOTAL COOLING CAPACITY (BTUH): 1,626,066 SENSIBLE CAPACITY (BTUH): 1,308,149 TOTAL AIRFLOW (CFM) 44,500 OUTDOOR AIR (CFM) 10,000-44,500 ESTIMATED REFRIGERANT CHARGE (LBS. R410A) 575 E.E.R @ DESIGN CONDITIONS (AS SHIPPED) 9.5 E.E.R @ ARI 360 CONDITIONS 11.5 54 COMPRESSOR SECTION COMPRESSOR: COPELAND SCROLL NUMBER 6 58 STAGES OF CAPACITY 6 ### AIR COOLED CONDENSER SECTION 61 CONDENSER COIL: COIL FACE AREA/ROWS/FPI 275.0/6/11 64 DESIGN AMBIENT TEMPERATURE (FDB): 102.0 65 CONDENSER FANS: PROPELLER DIA/RPM 30/1,140 QTY/HP 12/1.0 90 COOLING COIL SECTION FACE AREA (SQ-FT) 90.6 ROWS/FPI 6/9 COIL CIRCUITS (NUMBER) 6 TOTAL CAPACITY (BTUH) 1,626,066 #### SENSIBLE CAPACITY (BTUH) 1,308,149 ENTERING AIR TEMP (FDB/FWB) 85.0/67.5 COIL LEAVING AIR TEMP (FDB/FWB) 58.3/55.8 CONDITIONED AIR (CFM) 44,500 324 SUPPLY AIR BLOWER SECTION AF SWSI PLENUM NUMBER/SIZE 1/44.5" AIRFLOW (CFM) 44,500 TOTAL STATIC PRESSURE (TSP) IN WC 5.08 EXTERNAL STATIC (ESP) IN WC 2.50 DESIGN FAN SPEED (RPM) 1,078 FAN BHP (INCLUDING DRIVE LOSSES) 50.8 MOTOR HP 75.0 MOTOR DRIVE DIRECT DRIVE SEASONS 4 Inc. 4500 Ind. Access Rd. Page 1 Douglasville, GA 30134

358 EXHAUST AIR FAN SECTION ENGINEERING SPECIFICATIONS PROPELLER NUMBER/SIZE 1/48" AIRFLOW (CFM) 34,500 TOTAL STATIC PRESSURE (TSP) IN WC 1.35 EXTERNAL STATIC (ESP) IN WC 1.00 DESIGN FAN SPEED (RPM) 1,080 FAN BHP (INCLUDING DRIVE LOSSES) 16.3 MOTOR HP 20.0 MOTOR DRIVE DIRECT DRIVE 379 PRE-FILTER SECTION 2" PLEATED NUMBER/SIZE 20/24x24, 5/12x24 TOTAL FACE AREA (SQ-FT) 90.0 FACE VELOCITY (FPM) 494 #### AIR PRESSURE DROP 0.25" CLEAN / 0.50" (DIRTY) 386 CARTRIDGE FILTER SECTION 12" CARTRIDGE (95% EFFICIENCY) NUMBER/SIZE 20/24x24, 5/12x24 TOTAL FACE AREA (SQ-FT) 90.0 FACE VELOCITY (FPM) 494 #### AIR PRESSURE DROP 0.58" (CLEAN) / 1.0" (DIRTY) 393 HEPA FILTER SECTION (FUTURE) 12" HEPA (HIGH CAPACITY) NUMBER/SIZE 20/24x24, 5/12x24 TOTAL FACE AREA (SQ-FT) 90.0 FACE VELOCITY (FPM) 494 #### AIR PRESSURE DROP 1.4" ### UNIT SPLIT WEIGHT SECTION SECTION 1 (CONDENSER, COMPRESSOR & ECONOMIZER SECTION) 14,200 SECTION 2 (SA FAN, FILTERS & DX-COIL SECTION) 13,850 808 UNIT WEIGHT (LBS) 29,950 SEASONS 4 Inc. 4500 Ind. Access Rd. Page 2 Douglasville, GA 30134

ENGINEERING SPECIFICATIONS ELECTRICAL DATA JOB NAME LOCATION OPTI SOLAR MCCLELLAN, CA DATE PREPARED Revised: 07/29/08 SEASONS-4 REF NUMBER A167-01 UNIT MODEL 3SST45-1356-XXXXX-45SE 13 UNIT DESIGNATION 03-HVAC-ACU-01C TO 03-HVAC-ACU-09C SYSTEM VOLTAGE 460 CONTROL VOLTAGE 120 EXT. VOLTAGE 24 ITEM QTY HP FLA LRA KW 18 COMPRESSOR 1 6 *** 33.9 225.0 18.7 ZP235KCE COND FAN(1) 12 1.0 2.0 12.0 1.0 SA FAN 1 75.0 85.0 522.0 39.9 Bald EXH FAN 1 20.0 23.5 160.8 13.1 Bald CONTROL CKT 3.3 CONVENIENCE OUTLET 3.3 10 Amps 72 ------ ----------- ----------- ----------- ----------- TOTALS (COOL) 20 *** 342.4 177.1 TOTALS (HEAT) 2 95.0 115.0 52.9 M.C.A. 364 (MINIMUM CIRCUIT AMPACITY) M.O.P. 400 (MAXIMUM OVERLOAD PROTECTION) S.C.C.R. 65,000 (SHORT CIRCUIT CURRENT RATING) 83 SEASONS 4 Inc. 4500 Ind. Access Rd. Page 3 Douglasville, GA 30134