INSTALLATION INSTRUCTIONS

Similar documents
REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

REPLACEMENT PARTS MANUAL

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

REPLACEMENT PARTS MANUAL

THE WALL-MOUNT TM SIX TON AIR CONDITIONER

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS ELECTRIC HEAT PACKAGES

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

THE WALL-MOUNT QUIET CLIMATE HEAT PUMPS

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST. For Use with Bard 3-1/2 thru 5 Ton Wall Mount Air Conditioners and Heat Pumps

Installation Instructions

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST

Q-TEC QC-Series Chilled Water Air Conditioner

REPLACEMENT PARTS MANUAL

INSTALLATION INSTRUCTIONS ELECTRIC HEAT PACKAGES

THE WALL-MOUNT Quiet Climate A/C 10.0 EER

Q-Tec TM QC-Series Chilled Water Air Conditioner

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

INSTALLATION INSTRUCTIONS ERVR-A3D-X ERVR-C3D-X RETROFIT ENERGY RECOVERY VENTILATOR

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

INSTALLATION INSTRUCTIONS

Green Refrigerant. THE WALL-MOUNT STEP CAPACITY AIR CONDITIONERS Integrated Part Load Value (IPLV) Efficiency Up To 15.3 BTU/WATT. Engineered Features

REPLACEMENT PARTS MANUAL

Models: Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage List Control Panel. Blower Assembly

THE WALL-MOUNT AIR CONDITIONERS (50HZ)

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WGERV-A3A WGERV-C3A WGERV-A5A WGERV-C5A WGSERV-A5 WGSERV-C5

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS W12A2-A W12A1-K

INSTALLATION INSTRUCTIONS TEC40 ELECTRONIC CONTROLLER

Product Guide. Wallmount. Air Conditioners & Heat Pumps

OPERATION AND MAINTENANCE MANUAL. Vertical Fan Coil

GREEN REFRIGERANT R-410A

INSTALLATION INSTRUCTIONS

WALL-MOUNT HEAT PUMPS - (60HZ)

INSTALLATION INSTRUCTIONS HIGH EFFICIENCY PACKAGED AIR CONDITIONER

E3EH-xxx-H Series E3EB-xxx-H Series

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Q-TEC Q24A-Q60A Air Conditioners

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS MODELS W18H1 W24H1 W30H1 W36H1 W42H1 W48H1 W60H1

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WFERV. Bard Manufacturing Company, Inc.

Installation Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions

QW SERIES WALL SLEEVE (THROUGH WINDOW OPENING) INSTALLATION INSTRUCTIONS. Bard Manufacturing Company, Inc. Bryan, Ohio 43506

INSTALLATION, OPERATION & QUICK START GUIDE

MODEL 1830/1850/1870 DEHUMIDIFIER APPLICATION QUICK START GUIDE

RE9X Series Downflow, Upflow Electric Furnaces

INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL LIST OF SECTIONS. 1 General 1 3 Louvered Door Frame Assembly Installation 3 2 Safety 2 4 Coil Cabinet Installation 5

LOW VOLTAGE CONTROL CIRCUIT WIRING

Installation Instructions

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS WH421 WH483 WH602

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMP WH184 WH242

E2 Series. Downflow, Upflow Electric Furnaces TECHNICAL SPECIFICATIONS. Features and Benefits

INSTALLATION INSTRUCTIONS MASTER CONTROLLERS MC91AE MC92AE MC93AE MC94AE MC94AEH MC96AEH

ACCESSORY INSTALLATION INSTRUCTION ELECTRIC HEAT ACCESSORY 10, 16, 26, 36 & 72

Heatrix Electric Duct Heater HXOB Installation Instructions

Installation Instructions

The Wall-Mount Variable Capacity Environmental Control Units. Green Refrigerant

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS WH381 WH431 WH491

Installation Instructions

INSTALLATION INSTRUCTIONS

Q-TEC Q24H3-Q60H3 Air-to-Air Heat Pump 10 EER Units

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMP WH184 WH242

INSTALLATION INSTRUCTIONS

E3EB-xxx-H Series Downflow, Upflow Electric Furnaces

INSTALLATION INSTRUCTIONS MASTER CONTROLLERS MC91AE MC92AE MC93AE MC94AE MC94AEH MC96AEH MC97AE-1

INSTALLATION INSTRUCTIONS

THE WALL-MOUNT GAS/ELECTRIC Low NOx Certified Models

Installation Instructions Remote Blowers

E4EB-xxx-H Series Downflow, Upflow Electric Furnaces

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

HRV Vertical Unit Ventilators

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Types SDRA and SDRA-RG RENEWAL PARTS IDENTIFICATION

The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT NOx Certified Models

INSTALLATION INSTRUCTIONS

SPXR-A / SPXR-HP-A Series Single Package Vertical Unit Straight Cool and Heat Pump 3/4 through 2 tons, up to 10 kw Electric Heat

I-TEC ERV Economizer Ventilator System (Vent Code "E")

Installation and Maintenance Manual IM 1102

Dexter Industrial On Premise Dryer. Troubleshooting, Fault Codes, And Schematics. Starting serial number Part # /13

SEQUENCE OF OPERATION GUIDELINE. AIR TERMINAL UNITS SINGLE DUCT VARIABLE AIR VOLUME with HOT WATER REHEAT or ELECTRIC HEAT

SECTION AIR HANDLING UNIT

FCI500/600/FVI500/FCL/FVL600/FCQ-700 Installation and Maintenance Manual

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

INSTALLATION INSTRUCTION

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

SUBMITTAL SCHEDULE & DATA

CLe-series Dishwashers

Installation Instructions

Installation. Professional Built-in Hoods

Transcription:

INSTALLATION INSTRUCTIONS MOTORIZED FRESH AIR DAMPER Models: WMFADP2 WMFADP3 WMFADP5 Bard Manufacturing Company, Inc. Bryan, Ohio 43506 www.bardhvac.com Manual: 2100-650 Supersedes: NEW Date: 3-18-16 Page 1 of 6

Contents MFAD General Information... 3 Description... 3 Application... 3 Installation... 5 Figures Figure 1... 5 Figure 2... 5 Figure 3A... 6 Figure 3B... 6 Tables Table 1A MFAD-2, MFAD-3... 3 Table 1B MFAD-5... 3 Table 2 MFAD-2 Vent. Air Supplied at Static Pressures... 3 Table 3 MFAD-3 Vent. Air Supplied at Static Table 4 MFAD-3 Vent. Air Supplied at Static Table 5 MFAD-5 Vent. Air Supplied at Static Table 6 MFAD-5 Vent. Air Supplied at Static Page 2 of 6

GENERAL INFORMATION DESCRIPTION The motorized fresh air damper WMFADP2, WMFADP3 and WMFADP5 are internally mounted dampers designed to bring up to 25% fresh air. The damper blade is powered by a 24 VAC motor with spring return on power loss. The damper is powered open anytime the unit blower motor is energized, unless wired to A terminal and using demand ventilation (see Step 8 on page 5). APPLICATION The amount of outside fresh air brought into the structure is dependent on the supply and return duct static pressure present in the duct system. Refer to Tables 2 5 for ventilation air that will be supplied at different duct static pressures. For duct free applications with return air filter grille and supply grille use supply air static pressure and 0.1 return air static pressure. TABLE 1A WMFADP2, WMFADP3 Suitable for These Units TABLE 1B WMFADP5 Suitable for These Units WMFADP2 W18A*-A W18A*-D W24A*-A W24A*-B W24A*-D W24A*-F W18H*-A W24H*-A W24H*-B W24H*-C W24H*LA * Latest Revision Level W30A*-A W30A*-B W30A*-C W30A*-D W30A*-F W30H*-A W30H*-B W30H*-C W30H*LA W30H*LB S31H*-A S31H*-B S31H*-C WMFADP3 W36A*-A W36A*-B W36A*-C W36A*-D W36A*-E W36A*-F W36H*-A W36H*-B W36H*-C W36H*LA W36H*LB S38H*-A S38H*-B S38H*-C W42A*-A W42A*-B W42A*-C W42A*-E W42A*-F W42H*-A W42H*-B W42H*-C W42H*LA W42H*LB W42H*LC W48A*-A W48A*-B W48A*-C W48A*-E W48A*-F W48H*-A W48H*-B W48H*-C W48H*LA W48H*LB W48H*LC * Latest Revision Level WMFADP5 W60A*-A W60A*-B W60A*-C W60A*-E W60A*-F W72A*-A W72A*-B W72A*-C W72A*-F W60H*-A W60H*-B W60H*-C W60H*LA W60H*LB W60H*LC S43A*-A S43A*-B S43A*-C S49H*-A S49H*-B S49H*-C S61H*-A S61H*-B S61H*-C TABLE 2 WMFADP2 Ventilation Air Supplied at Static Pressures Ventilation Air (CFM) Return Air Static Pressure 85 135 190 240 295.00.05.10.15.20 Page 3 of 6

TABLE 3 WMFADP3 for Models W30A*, W36A*, W30H* and W36H* 75 235 410 545 615 50 225 405 510 N/A TABLE 4 WMFADP3 for Models S31H* and S38H* 40 235 380 460 N/A 30 225 370 450 N/A TABLE 5 WMFADP5 for Models W42A*, W48A*, W60A*, W42H*, W48H* and W60H* 285 305 390 455 545 240 280 360 435 525 TABLE 6 WMFADP5 for Models S43H*, S49H* and S61H* 195 260 365 450 540 Blower Speed Medium 170 250 355 440 530 145 240 345 430 520 With supply grille installed Page 4 of 6

INSTALLATION 1. Disconnect all power to wall mount unit before installing WMFAD. 2. Remove service door (see Figure 1). Remove fresh air damper or blank-off plate if installed on service door. Remove one (1) screw from top of front condenser grille (see Figure 3A on page 6). 3. The exhaust cover plate must be in place when an WMFAD-2, -3 or -5 is installed (see Figure 2). 4. Install WMFAD with hole in front lip of WMFAD centered over hole in condenser partition (see Figure 3A). 5. Position WMFAD with front lip over condenser partition and under front grille as shown in Figure 3B on page 6. This is important to insure proper drainage of any water entering damper assembly. 6. Use a self-drilling screw through hole provided in left mounting flange to secure WMFAD in position (see Figure 3A). 7. Route wires as shown in Figure 3A into unit low voltage terminal strip area. For left hand units unclip two wire ties on right half of the WMFAD. Reroute wire down the left side. Route wires into low voltage terminal strip area. 8. Connect black wire to C terminal of low voltage terminal block. Connect red wire to A terminal on air conditioners and O1 on heat pumps when the thermostat or control system has dedicated ventilation control output capability. Otherwise, connect the red wire to G in which case the motorized fresh air damper will open whenever the indoor blower is operating. 9. Check WMFAD for proper operation. The blower needs to energize whenever the WMFAD is energized. 10. Replace four (4) screws in front condenser grille and replace service door. Plug four holes in service door with plastic plugs provided. FIGURE 1 FIGURE 2 SERVICE DOOR EXHAUST COVER PLATE MIS-356 Page 5 of 6

FIGURE 3A LEFT HAND UNITS LEFT HAND UNITS RIGHT HAND UNITS RIGHT HAND UNITS USE A SELF- DRILLING SCREW USE MFADA TO SELF- THE COND. DRILLING PART. SCREW MFAD TO THE COND. PART. ROUTE WIRE PLUG ROUTE WIRE PLUG REMOVE (1) SCREW FROM FRONT OF CONTROL CONDENSER GRILL WHEN USE A SELF- FRONT OF CONTROL PANEL ROUTEAND WIRE PLUG PLUG IN INSTALLING MFAD, MAKE DRILLING SCREW ROUTE PANEL AND WIRE PLUGIN REMOVE SURE (1) SCREW THAT HOLE FROM IN FRONT OF CONTROL FRONT CONDENSER LIP IS POSITIONED GRILL WHEN USE MFADA TO SELF- THE FRONT OF CONTROL PANEL AND PLUG IN OVER INSTALLING HOLE CONDENSER MFAD, MAKE COND. DRILLING PART. SCREW PANEL AND PLUG IN GRILLESURE TO INSERT THAT HOLE A SELF- IN FRONT LIP DRILLING IS POSITIONED SCREW. CAUTION: HOLE IN MFAD MFAD MUST TO THE OVER HOLE IN CONDENSER BE USED TO ENSURECOND. CLEARANCE PART. GRILLE TO INSERT A SELF- FROM CONDENSER COIL TUBING. DRILLING SCREW. CAUTION: HOLE IN MFAD MUST BE USED TO ENSURE CLEARANCE FROM CONDENSER COIL TUBING. FIGURE 3B MOTORIZED FRESH SIDE SECTION SERVICE DOOR AIR DAMPER (SOME COMPONENTS REMOVED FOR CLARITY) MOTORIZED FRESH SIDE SECTION SERVICE DOOR AIR DAMPER (SOME COMPONENTS REMOVED FOR CLARITY) LIP OF MFAD IS TO BE BETWEEN THE CONDENSER GRILLE AND SERVICE DOOR LIP OF MFAD IS TO BE BETWEEN THE CONDENSER FRONT GRILLE GRILLE AND SERVICE DOOR FRONT GRILLE CONDENSER PARTITION CONDENSER PARTITION MIS-424 A MIS-424 A Page 6 of 6