Product data sheet AIRWIN BO-FK-120J Humidity sensors

Similar documents
Product data sheet AIRWIN BO-120 Hygrostats

D Series Sensors for Humidity and Temperature Measurement With calibrated dmodul

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

Duct Humidity and Temperature Sensors 0-10 Vdc or 4-20 ma Outputs Passive sensor PT1000, PT100 NTC, NI1000 etc. Features. IP65 protection.

Hygro and hygrothermo transducers (capacitive) for HVAC monitoring

Duct Humidity and Temperature Transmitter. Features. IP65 protection. Ordering

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

PM100V PM80V PM15V. Ex works. Depending on the specific range of application a regular ecalibration of the sensor head (PMU-V) has to be effected.

for relative humidity and temperature with calibration certificates

Hygrostats (hygrometric)

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

Beck. The differential pressure transmitter for air

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

Specifications: ACCURACY: RH: ±1% Temperature: ±0.5 C. Dew point: Typically, +/-2.0C above 0C; +/-3.0C 0 to -60C OPERATING RANGE:

for relative humidity and temperature

Relative Humidity Transmitters

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

Sensor unit MC2 with analog output for Freon gases and refrigerants

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

Technical data Humidity Temperatur General data Electrical data Two designs duct version (LK) wall mounting

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

DMFPM-2R MULTIFUNCTIONAL

QFM21... Duct sensors. Symaro. for relative humidity and temperature

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

Sitron s CF Line of Flow Switch Monitors

FTK+ Application. Types Available. Duct sensor for humidity and temperature. Datasheet

Snifter. User Manual. Distributor

Snifter ATEX22 VERSION. User Manual. Distributor

HSD Dry Cabinet

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

HSD Dry Cabinet. Outstanding performance

Content. Heating. Ventilating. Regulating and Monitoring. Lighting. Accessories

ELECTRONIC HUMIDISTAT: H200

Line Smoke Detector LRMX

SD Storage Cabinet. Outstanding performance

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

RH & T Sensors & Humidistats. RH-DT Duct Mount RH & T Sensors. Description

Hygro/hygrothermal transducers (hygrometric)

for relative humidity and temperature

HSD Dry Cabinet. Outstanding performance

Sensors Product Overview. Reliable And Accurate Honeywell Sensors

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

METAL SHARK COMBI Flat metal detector for textile and non-woven products. Metal sensitivity from Fe 0,3 mm

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

TER Active Room Temperature Sensor (Controller),

MF-PFA ver 3.x. Micaflex PFA ver 3. Pressure- and Flow transmitter with alarmfunction. Installation- & Operation manual [Dok. id: mi-303gb_180528]

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

Accessories, interfaces, sensors and complete solutions.

Bionics Instrument. Alarm Handling. Gas Alarm Systems

DTA. Motor thermistor relay. Benefits. Description

PolyGard 2-channel Gas Controller MGC-03

APM110 LOW AIR VELOCITY ALARM

Humidity Meters. hygrometers & therma-hygrometers. what is a hygrometer? applications. monitor humidity levels for better health. Humidity.

ELECTRONIC HUMIDISTAT: H270

A and B Series Sensors for humidity and temperature for digital transfer RS485 / MODBUS-RTU or RS232

FA compressed air plants (refrigeration/adsorption driers) - granulate driers - medical gases - non-corrosive gases, e. g.

0-10 V Wall & Duct Humidistat Installation Instructions

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

Active Infrared Sensor OA-EDGE1/EDGE2. to the sensor module d4 = Distance from the pivot edge to the sensor module n = Number of sensor modules h

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

Product data sheet AIRWIN additional modules Accessories AIRWIN

AIRFLOW MEASUREMENT AND CONTROL PRODUCT CATALOG. Phone: 877-4GNTROL ( ) - Internet: GreenTrol.com. r1f

WRF04 CO2. Application. Types Available. Security Advice Caution. Combined room sensor CO 2 / temperature / humidity. Datasheet

Guide Specification - MasterFormat 2017 Style SECTION FLOW INSTRUMENTS PART 2 PRODUCTS 2.1 SECTION INCLUDES 2.2 ACCEPTABLE MANUFACTURERS

DTA04. Motor thermistor relay. Benefits. Description

ORION-FWS. Computer for feed weighing

Topscan G3 Presence detector for automatic doors

VERSO-P, VERSO-R Series Air Handling Units with C3 Control System Electrical Installation and Operation Manual

CO2 transmitters TRANSMITTERS TO DETECT CARBON DIOXIDE (CO 2 )

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Resistance heaters. Ventilation systems. Air-air exchangers. Air-water exchangers. Cooling units. Control devices. Calculation and selection

WRF04 CO 2 RS485 Modbus

Operating instructions DVC-P / Bedienungsanleitung Druckregler DVC-P

Using the DewTrak II Dew Point/ Humidity Transmitter

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Infrared Moisture Balance (FD-660)

Air Quality Sensors. Particle Matter, CO 2, Humidity, Temperature and Dust Products. OEM Sensor Components for Air Quality and Environmental Control

Version 3 Controls for smoke and natural ventilation. WLS xxm Smoke control panel LON MotorLink

CATALOGUE 2017 ELECTRICAL BOARDS FOR REFRIGERATION

R A D I O N I C S. READYKEY K2015A Alarm Event Manager. Installation Data Sheet. Description

XSD Dry Cabinet

Hygro/hygrothermal transducers (hygrometric)

Ventostat Wall Mount. Amphenol. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Advanced Sensors. Features:

T7984 A,B,C Electronic Modulating Control Thermostats

Series SHR-5620 Digital Display Volumetric Meter Operation Instruction

THERMASREG TR 040 THERMASREG TR 060

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

ORION-PL Poultry computer for cage houses

Specification , July 2015

GB Art. Nr

Advantages / Characteristics

Version 4 Controls for smoke and natural ventilation. CompactSmoke WSC 310 / WSC 320 PLUS Smoke control panel 10-20A

Transcription:

Product data sheet AIRWIN BO-FK-120J The room humidity sensor BO-FK-120-J is used in offices and computer rooms to measure the relative air humidity. Other fields of application for BO-FK-120J are the storage of food and beverages, cold stores for fruit and vegetables, greenhouses in horticulture, the textile, paper and printing industry, the film industry and hospitals. Room humidity sensor Capacitive measuring element Installation-friendly housing made of impact-resistant plastic, light grey To be used up to 60 C Work range 10...95 %RH ± 3.5 %RH Temperature ± 0.05 %RH/K Output 0... 10 V Auto-consumption 15 ma Built-in dimensions housing Height x width x depth 70 x 115 x 43 mm Weight 0.2 kg Supply voltage 15... 24 VDC 24 VAC Max. operating temperature -10...+60 C IP20, non-condensing Max. air speed 15 m/s BO-FK-120J room humidity sensor Type BO-FK-120J Item no. 6100098

Product data sheet AIRWIN BO-FWL The room humidity sensor BO-FWL is especially suitable for applications in the ventilation and air-conditioning industry. It can be mounted directly on the wall. Room humidity sensor Assembly-friendly housing made of ABC, light grey To be used up to 60 C Measuring range 0... 100 %RH Work range 15... 90 %RH Measurement uncertainty at 40 60 %RH ± 3 %RH at < 40 or > 60 %RH ± 5 %RH Influence of temperature ± 0.2 %RH/K Output 0... 10 V Auto-consumption < 6 ma Built-in dimensions Height x width x depth 75 x 75 x 27 mm Weight 0.08 kg Supply voltage 15...30 VDC Operating temperature - 20..+60 C IP20 BO-FWL room humidity sensor Type BO-FWL Item no. 6100106

Product data sheet AIRWIN BO-LIF The room humidity sensor BO-LIF is especially suitable for applications in the ventilation and air-conditioning industry. It can be mounted directly on the wall. Room humidity sensor Calibrated sensor chip Installation-friendly housing from ABC, white To be used up to 60 C calibrated sensor chip Output area 0... 100 %RH Masuring accuracy at 30 80 %RH ± 3 %RH at < 30 or > 80 %RH ± 5 %RH Influence of temperature at <10 C or >40 C ± 0.06 %RH/K Output 0... 10 V Auto-consumption <1 ma Built-in dimensions Height x width x depth 81 x 81 x 26 mm Weight 0.1 kg Supply voltage 12... 30 VDC Operating emperature - 20 +60 C IP30, non-condensing BO-LIF room humidity sensor Type BO-LIF Item no. 6100107

Product data sheet AIRWIN BO-DIK The room humidity and temperature sensor BO-DIK is used in offices and computer rooms for the measurement of the relative air humidity depending on the temperature. Other fields of application for BO-DIK are the storage of food and beverages, cold stores for fruit and vegetables, greenhouses in horticulture, the textile, paper and printing industry, the film industry and hospitals. Room humidity and temperature sensor with display Dynamic humidity sensor element Calibrated module for the measurement of temperature and humidity Integrated measuring chamber Installation-friendly housing made of ABS, colour RAL 9003 (signal white) To be used up to 50 C Digital display: 2 lines, 3 digits + 1 decimal place, display approx. 21 mm x 40 mm, digit height ca. 8 mm Humidity Meausrement element Output range 0...100 %RH at 10 40 %RH ± 3 %RH at 40 60 %RH ± 2.5 %RH at 60 90 %RH ± 3 %RH Influence on temperature at 23 C ± 0.05 %RH/K Temperature PTC thermistor at 10... 40 C ± 0.25 K Influence on temperature < 10 or > 40 C ± 0.01 K/K Output 2 x 0...10 V Auto-consumption 7 ma Installation dimensions height x width x depth 81 x 81 x 28 mm Weight 0.07 kg Supply voltage 15...30 VDC 13 26 VAC Operating temperature 0... +50 C IP30D air, pressure less, non-aggressive BO-DIK room humidity and temperature sensor with display Model BO-DIK Item no. 6100110

Product data sheet AIRWIN BO-DWF The BO-DWF room humidity sensor is used in offices and computer rooms to measure the relative air humidity. Other fields of application for BO-DWF are the storage of food and beverages, cold stores for fruit and vegetables, greenhouses in horticulture, the textile, paper and printing industry, the film industry and hospitals. Room humidity sensor Dynamic measuring element Output for all hx sizes possible Calibrated module for humidity measurement On-site adjustment Installation-friendly housing made of impact-resistant plastic, light grey To be used up to 80 C Output range 0... 100 %RH at 10 90 %RH ± 2 %RH at < 10 or > 90 %RH ± 2.5 %RH Influence of temperature at <10 C or >40 C ± 0.05 %RH/K Output 1 x 0... 10 V Auto-consumption 7 ma Built-in dimensions of housing Height x width x depth 133 x 83 x 40 mm Weight 0.14 kg Supply voltage 15... 30 VDC 13 26 VAC Operating temperature -30... +80 C housing IP65 measuring head IP30 Min. air speed > 0.5 m/s Max. air speed 10 m/s BO-DWF room humidity sensor Model BO-DWF Item no. 6100109

Product data sheet AIRWIN BO-FK-80J The duct humidity sensor BO-FK-80-J is used in air conditioning systems and climate cabinets to measure the relative air humidity. Other fields of application for BO-FK-80-J are the storage of food and beverages, cold stores for fruit and vegetables, greenhouses in horticulture, the textile, paper and printing industry, the film industry and hospitals. Duct humidity sensor Capacitive measuring element Voltage output 0... 10 VDC Assembly-friendly housing made of ABS, light grey To be used up to 60 C Measuring range 0... 100 %RH Work range 5... 95 %RH at 40 60 %RH ± 2 %RH at < 40 or > 60 %RH ± 2.5 %RH Influence of temperature <0.15 %RH/K Output 0... 10 V Auto-consumption < 5 ma Built-in dimensions housing Height x width x depth 120 x 80 x 48 mm Sensor length 200 mm Weight 0.3 kg Supply voltage 15... 30 VDC Max. operating temperature sensor -40...+80 C Max. usage temperature housing -10...+60 C IP64 Max. air speed 15 m/s BO-FK-80J duct humidity sensor Type BO-FK-80J Item no. 6100099

Product data sheet AIRWIN BO-DKF The duct humidity sensor BO-DKF is used in air conditioning systems and climate cabinets to measure the relative air humidity. Other fields of application for BO-DKF are the storage of food and beverages, cold stores for fruit and vegetables, greenhouses in horticulture, the textile, paper and printing industry, the film industry and hospitals. Duct humidity sensor Dynamic humidity sensor element Output for all hx sizes possible Calibrated module for humidity measurement On-site adjustment Assembly-friendly housing made of PC To be used up to 80 C Output range 0... 100 %RH at 10 90 %RH ± 2 %RH at < 10 or > 90 %RH ± 2.5 %RH Influence of temperature <10 C or >40 C ± 0.05 %RH/K Output 1 x 0... 10 V Auto-consumption 7 ma Built in dimensions of housing Height x width x depth 83 x 83 x 40 mm Sensor pipe length 220 mm Weight 0.16 kg Supply voltage 15... 30 VDC 13 26 VAC Operating temperature -40... +80 C housing IP65 measuring head IP30 Min. air speed 0.5 m/s Max. air speed 10 m/s BO-DKF duct humidity sensor Model BO-DKF Item no. 6100112

Product data sheet AIRWIN BO-DKK The duct humidity and temperature sensor BO-DKK with display is used in air conditioning systems and climate cabinets to measure the relative room humidity depending on the temperature. Other fields of application for BO-DKK are the storage of food and beverages, cold stores for fruit and vegetables, greenhouses in horticulture, the textile, paper and printing industry, the film industry and hospitals. Duct humidity and temperature sensor with display Dynamic humidity sensor element Output for all hx sizes possible Calibrated module for humidity and temperature measurement On-site adjustment Assembly-friendly housing made of PC To be used up to 80 C Digital display: 2 lines, 3 digits + 1 decimal place, display approx. 21 mm x 40 mm, digit height ca. 8 mm Humidity Measurement element Output area 0... 100 %RH at 10 90 %RH ± 2 %RH at < 10 or > 90 %RH ± 2.5 %RH Influence of temperature at <10 C or >40 C ± 0.05 %RH/K Temperature PTC thermistor at 10... 40 C ± 0.25 K Influence of temperature < 10 or > 40 C ± 0.01 K/K Output 2 x 0... 10 V Auto-consumption 7 ma Built-in dimensions of housing Height x width x depth 83 x 83 x 40 mm Sensor pipe length 220 mm Weight 0.17 kg Supply voltage 15... 30 VDC 13 26 VAC Operating temperature -30... +80 C housing IP65 measuring head IP30 Min. air speed 0.5 m/s Max. air speed 10 m/s BO-DKK duct humidity and temperature sensor with display Model BO-DKK Artikel-Nr. 6100111