mini-compacta Type Series Booklet

Similar documents
Automatic Waste Water Lifting Unit. Ama-Drainer-Box Mini. Type Series Booklet

Submersible Waste Water Pump. Ama-Drainer N 301/302/ Hz. Type Series Booklet

Submersible Waste Water Pump. Ama-Drainer N 301/302/303/358. Type Series Booklet

Automatic Waste Water Lifting Unit

Cleaning System. Amajet. Type Series Booklet

Calio-Therm S NC/NCV Type Series Booklet

50 Hz. Submersible Waste Water Pumps

Vertical Ring-section Pump WKTB. Type Series Booklet

Sekamatik series PREFABRICATED LIFTING STATIONS FOR RESIDENTIAL, COMMERCIAL OR INDUSTRIAL APPLICATIONS

Lifting Plants Product Overview

Building Services. KSB Building Services. A Real Welcome Home.

MULTISAN Fully automatic sewage and waste water pump

TYPE POS Oil Shield Sump Pump

Trusted Expertise in Domestic and Commercial Wastewater

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

SL EX.4.51D

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz

SL S.S.N.51D

FEATURES. Other Fed-Flush Arrangements

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz

JUNG PUMPEN LIFTING STATIONS

aquaconcept Cold water

Data sheet: Wilo-RainSystem AF Comfort MC 304

Instruction manual. Submersible sump pump. Safety instructions Application Electrical connection Installation Maintenance Technical data

Lifting Station Type ABS Sanimax

Comfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W

V80-H Multistage Pump Instruction Manual

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with two or three CM, CMV or CR pumps. 50 Hz

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz

NEWS 2017 SANIFLO. Pumps and pumping stations

CRU-S Series Stainless Steel Condensate Recovery Unit

VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

X1 series Submersible Drainage Pump

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

Sanitary Drainage Systems

Choosing the Right Pump

Technical data. Unilift KP. CRUNDFOS "~ ozpump.com.au Drainage pumps. Unilift KP

Block Macerators Series ABM-2-S

2016 Plumbing Supplemental Plan Review List

GRUNDFOS PRODUCT GUIDE. Unilift CC, KP, AP. Submersible wastewater pumps 60 Hz

ECONOBOOST EB II & EB III Compact Water Booster

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

GIANT. Little. Guidelines for Sizing. Pump Company. Sewage Pumps & Systems. Sewage Pumps & Systems

EW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS

aquaconcept Cold water

Type VSA Suspended Wet Pit Sewage Pumps BULLETIN 228E-1 September 2014

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

OPTISENS TUR 2000 Technical Datasheet

Company name: Created by: Phone:

SUPPLEMENTARY INSTRUCTIONS

Electric Submersible Pumps

Wastewater. Guidelines for Sizing mscdirect.com. Call MSC today to learn about the latest LittleGiant products.

Washing machine PW 6055 AV/LP PW 6065 AV/LP. en - GB. Installation plan

Protecting you and your home

GRUNDFOS. Multilift PRODUCTS. MSS, M, MOG, MD, MLD, MDG and MD1/V

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC

TP /4-A-F-A-BQQE 400D 50HZ

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with 2 or 3 CM, CMV or CR pumps 50 Hz

UPZ PUMP POWER FOR TOP PERFORMANCE UNDER

UV Flame Supervision System

NON-SUBMERSIBLE WATER PUMP

Submersible Grinder Pump Type ABS Piranha S10 - PE125

Installation, Operating and Maintenance Instructions

Building Utilities 1 Plumbing and Sanitary Systems

CAP SERIES SEWAGE AND WASTE WATER PUMPS

LS Condensate Removal Pump INSTRUCTION MANUAL REVISION A

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

POWER and INTELLIGENCE

Heat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min

RQE Series Temperature Controllers

Technical information for installation and operation

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Alarm Switchgear AS1-M

Interface and EOL Modules 8

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

VRD. Sump pump for polluted liquids

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Washing machine PW 5064 MOPSTAR 60. en - GB. Installation plan

Condensing Heat Exchanger Suitable Gas Fired Ideal GT & GTE boiler ranges

INSTALLATION AND OPERATING INSTRUCTIONS

DRAINAGE AND SEWAGE. DRENA-LINE Residential Technology

Operating Instructions Edition 11/2005. Process monitoring Ex-barrier for Diagnostics Unit SITRANS DA400 7MJ2010-1AA. sitrans

GRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions

Process engineering. Collection and disposal of commercial food waste ACO Waste-Jet Wet refuse collection system

Friwa Compact. Operating instructions EN

CLEAN WATER PUMP. MODEL No: Hippo4A OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

Submersible Grinder Pump Type ABS Piranha S10 - PE125

Bedpan washer-disinfectors CT 100 Compact CT 100 Compact PERLAVO

Full-line Product Overview

Level Electrode NRG NRG Original Installation Instructions English

VacCalc. Help and Operating Instructions. Overview

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

LS Condensate Removal Pump Installation, Operation and Service Instructions

The easy solution for waste water removal

INSTALLATION, OPERATION & MAINTENANCE MANUAL

AirUnit. Installation instructions. mfh systems modern floor heating. Decentralised domestic ventilation

Macerator Pumps & Lifting Station. Technical presentation Part 1

Transcription:

Floodable Sewage Lifting Unit 60 Hz Type Series Booklet

Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed for any other purpose, nor otherwise transmitted, published or made available to a third party without the manufacturer's express written consent. Subject to technical modification without prior notice. KSB Aktiengesellschaft, Frankenthal 08/01/2018

Contents Contents Building Services: Drainage... 4... 4... 4 Main applications... 4 Fluids handled... 4 Operating data... 4 Duty cycles... 4 Designation... 4 Design details... 4 Configuration and function... 5 Materials... 6 Product benefits... 6 Certification... 6 Overview of product features... 7 Selection information... 8 Selection aid for drainage applications... 9 Special design on request... 9... 10 Characteristic curves... 11 Dimensions and connections... 12 Scope of supply... 18 Connection nozzles... 19 Control units and switchgear... 20 LevelControl Basic 1 product description... 20 LevelControl Basic 2 product description... 20 Combination of lifting and control units... 21 Accessories... 22 3

Building Services: Drainage Designation Example: UZ 2.150 D Key to the designation Code mini Compacta UZ Description Small package unit Type series Type of lifting unit U = single-pump lifting unit UZ = dual-pump lifting unit 2 Hydraulics code 150 Total volume of collecting tank [litres] 60 100 150 D D = three-phase motor Design details Design Floodable sewage lifting unit 1) to EN 12050-1 Gas-tight and water-tight plastic collecting tank, pump unit, sensors and control unit Ready-to-connect sewage lifting unit Main applications Disposal of waste water occurring below the flood level Waste water management Fluids handled Standard design: Waste water with faeces Waste water without faeces Grey water Variant C: Aggressive fluids Operating data Operating properties Characteristic Value Flow rate Q [m 3 /h] 36 Q [l/s] 10 Head H [m] 16 Fluid temperature T [ C] 40 (up to 65 C for max. 5 minutes) Drive Surface-cooled Three-phase motor Thermal overload protection To VDE 0530, Part 1/IEC 34-1 Enclosure IP68 (permanently submerged) to EN 60529 / IEC 529 Thermal class F Voltage 380 V Frequency 60 Hz DOL starting Impeller type Free-flow impeller Bearings Grease-packed, maintenance-free rolling element bearings Shaft seal Duty cycles Operation Intermittent duty Duty cycle S3 50 % to VDE U, UZ Impeller end: shaft seal ring Drive end: shaft seal ring A grease fill is provided between the impeller-end and drive-end shaft seals. 1) Maximum flooding height: 2 metres, maximum flooding period: 7 days (does not apply to control unit). The lifting unit must be cleaned and serviced after it has been flooded. 4

Variant C Impeller end: mechanical seal Drive end: shaft seal ring An oil reservoir, which is supplied filled with ecologically acceptable white oil, is fitted between the impeller-end mechanical seal and the drive-end shaft seal. Configuration and function 1 2 1 3 4 6 7 8 9 10 Fig. 1: LevelControl Basic 1 LevelControl Basic 2 Type BasicCompact (BC) Pump control and monitoring unit in compact plastic housing For either one or two pumps With display Level detection via: Level sensor 0-5 V DOL starting 5 1 Inlet 2 Level sensor 3 Motor with pump 4 Drain connection 5 Transport and float 6 Hand hole cover protection 7 Vent connection 8 Discharge outlet 9 Integrated check valve 10 Tank 3 1 Design The lifting unit is provided with a variety of horizontal/vertical inlet nozzles (1). The hydraulic system (3) pumps the fluid handled into the vertical discharge line (8). Function The fluid to be handled flows into the lifting unit through horizontal/vertical inlet nozzles (1) and is collected in a gas, odour and water-tight plastic tank (10). Controlled by a level sensor (2) and control unit, either one or two pumps (3) are started up automatically as soon as the defined fill level is reached. The fluid is pumped off to a level above the flood level, towards the public sewer. Control unit DANGER Flooding of control unit Danger of death from electric shock! Ø Operate the control unit in flood-proof rooms only. 2 Fig. 2: Type Basic Compact (BC) 1 Control panel 2 Master switch (optional) 3 Manual-0-automatic switch LevelControl Basic 2 Type Basic Control Cabinet (BS) Pump control and monitoring unit in sheet steel housing For either one or two pumps With display Level detection via: Level sensor 0-5 V DOL starting or star/delta starting LevelControl Basic 1 Pump control and monitoring unit in compact plastic housing For one pump Level detection via level sensor 0-5 V DOL starting 5

Certification Overview 3 Label Effective in: Comment Europe - 2 1 Fig. 3: Basic Control Cabinet (BS) 1 Master switch 2 Control panel 3 Manual-0-automatic switch NOTE The control units are not explosion-proof, and therefore must only be operated outside potentially explosive atmospheres. The control unit is always located outside the potentially explosive atmosphere and may only be installed in a floodproof room. Materials Overview of available materials Component Tank Pump casing Impeller Motor shaft Standard Variant C Polyethylene Polyethylene Ultradur Stainless steel (1.4021) Stainless steel (1.4462) Casing cover Grey cast iron Stainless steel (1.4408) Check valve Grey cast iron Stainless steel (1.4408) Float Polypropylene Screws, bolts and Stainless steel (A4) nuts Product benefits Safe and reliable operation ensured by control system (LevelControl Basic 1 / LevelControl Basic 2) Check valve ensures low-noise pump operation and normal, uninterrupted operation during maintenance work. Various positioning options and diameters make it easy to adapt the unit to the most complicated of site conditions. Collecting tank with optimum volume/footprint ratio for effective space utilisation Integrated, ergonomically designed grips for safe handling during transport and installation Ready-to-connect, easy installation and commissioning Low noise level 6

Overview of product features Overview of product features of single-pump units U60 Hydraulics code 2 H max. 16.0 m Q max. 36.0 m³/h Free passage of 40 mm Tank volume Installation examples Type 60 l Single-family houses, toilets, wash-basins and showers, secondary toilets and party rooms in the basement, toilets subsequently installed in refurbished buildings Small plug-in lifting unit in compact design, fully floodable, with gas and water-proof plastic collecting tank with integrated check valve, centrifugal pump with free-flow impeller for automatic operation via electronic control unit. Overview of product features of single-pump and dual-pump units Single-pump unit U100 Dual-pump unit UZ150 Hydraulics code 2 H max. 16 m Q max. 36 m³/h Free passage of 40 mm Tank volume 100 l 150 l Installation examples Single-family and two-family houses, building extensions, converted cellars, bathroom and sauna facilities for private use Basement flats, single-family and twofamily houses, sanitary facilities in cinemas, theatres, restaurants and bars as well as public swimming pools and sauna facilities Type Plug-in single-pump unit, fully floodable, with gas and water-proof plastic collecting tank with integrated check valve, centrifugal pump with free-flow impeller for automatic operation via electronic control unit. Plug-in, micro-processor controlled dualpump lifting unit, fully floodable, gas- and water-proof plastic collecting tank with two integrated check valves and Y-pipe, two centrifugal pumps with free-flow impeller for automatic alternate, stand-by and peak-load operation. 7

Selection information Requirements on installation at site (to EN 12056-4 or EN 12050-1,...) Domestic waste water which occurs below the flood level must be discharged into the public sewer by means of a lifting unit. Surface water which occurs below the flood level outside the building must be discharged into the public sewer separately from the domestic waste water by means of a lifting unit which is positioned outside the building. If the responsible authorities have not specified a flood level, the flood level is taken to be at least the street level (including footways) at the connection point. The flow velocity in the discharge line must equal between 0.7 m/s and 2.3 m/s. Lifting units must not be installed in outdoor pits. Install all electrical connections (e.g. sockets, CEE plugs) and alarm switchgears in dry rooms protected against flooding. The effective volume of the lifting unit must be greater than the volumetric content of the discharge line up to the backflow loop. Installation room: Sufficiently lit Well ventilated The rooms must be dimensioned so as to ensure that there is a working area of at least 60 cm width and height around and above all parts to be operated and serviced. Installation in suitable installation rooms only; unprotected outdoor installation is impermissible! Collecting tank: Not integrated into the structure of the building Separately installed within the building Pipe connections and piping layout: Flexible, with sound-proof insulation If changes of direction are unavoidable, the pipe should be laid with a gradient of at least 1:50. Minimum nominal diameter of the vent pipe connection DN 70 (DN 50 permissible up to an effective volume of 20 litres). Install a gate valve on the inlet side as well as on the discharge side downstream of the check valve (see accessories). Lay the discharge line with a backflow loop whose invert level is above the flood level. Lead the vent pipe out of the roof. Additional requirements on sewage lifting units: If sewage disposal must not be interrupted, install a dual-pump lifting unit. For drainage of rooms provide a pump sump. If a failure of any system functions could lead to flooding damage, additional measures must be taken to prevent any such damage (pump for drainage of rooms, humidity sensor next to the system close to the floor, etc). After any flooding, clean and service the lifting unit. All electrical equipment such as sockets, CEE plugs, control units and alarm switchgears must be installed in dry, floodproof rooms. Static head H geo UG1081456 Fig. 4: Static head H geo if installed correctly (1) Flood level Calculation of head: H Lifting unit = H Static + H Losses (discharge line) Application limits for S3 operation (1) The units are designed for S3 operation (intermittent operation). The max. permissible inflow must always be smaller than the capacity of one pump. Intermittent operation S3 50 % to VDE Max. number of start-ups: 60/hour For continuous discharge or repeated discharge over longer periods of time the maximum permissible frequency of starts must be observed! Flooding The lifting unit is protected against flooding. Max. submersion depth: 2 metres Max. flooding period: 7 days 8

Selection aid for drainage applications The table below for your guidance is based on KSB's long-standing experience. The data are standard values and are not to be considered as generally binding recommendations. They shall not be the basis for warranty claims. Please contact your nearest KSB sales branch and/or our technical departments for in depth advice. Selection aid for drainage applications Fluid handled Domestic waste water and faeces from bathtubs, showers, washbasins, bidets, toilets, urinals, sinks, floor drains, dishwashers and washing machines Waste water from commercial premises produced in kitchens, shower and toilet facilities, hospitals, hotels, sports facilities and swimming pools Condensate from condensing boiler equipment (DIN 1986-3) Waste water from kitchens For drainage of greasy water, a grease separator must be fitted. (DIN 4040-1) Waste water from laboratories (Permission under water and waterways legislation or discharge permit required, DIN 1986-3) Flushing water containing salt (seawater <15 C) Swimming pool water containing chlorine (DIN 19643) Aggressive waste water in low concentrations, ph 5 to 12, cleaning, disinfecting, washing-up and washing agents (DIN 1986-3) Waste water from garages, containing road salt Standard Variant C 2) Special design on request Systems for improved fire protection / halogen-free cables 2) Contact KSB with the relevant analysis, temperature and mode of operation. 9

Standard design with integrated check valve, UZ dual-pump units with Y-pipe, free passage of 40 mm Hydraulics code Dualpump units Singlepump units Total volume Effective volume 3) P 1 P 2 H = 180 mm H = 250 mm Vertical Speed 60 Hz 3~380 V Cable length Mat. No. No. [l] [l] [l] [l] [kw] [kw] [min -1 ] [A] [m] 2 - U2.60 D 60 20-30 1,75 1,5 3500 3,15 4+1 29131718 42 2 - U2.100 D 100 30 44 62 1,75 1,5 3500 3,15 4+1 29131719 49 2 UZ2.150 D - 150 57 83 91 1,75 1,5 3500 3,15 4+1 29131720 102 [kg] Variant C for aggressive fluids, with integrated check valve, free passage of 40 mm Hydraulics code Dualpump units Singlepump units Total volume Effective volume 3) P 1 P 2 H = 180 mm H = 250 mm Vertical Speed 60 Hz 3~380 V Cable length Mat. No. No. [l] [l] [l] [l] [kw] [kw] [min -1 ] [A] [m] 2 - U2.60 D/C 60 20-30 1,75 1,5 3500 3,15 4+1 29131721 42 2 - U2.100 D/C 100 30 44 62 1,75 1,5 3500 3,15 4+1 29131722 49 2 UZ2.150 D/C - 150 57 83 91 1,75 1,5 3500 3,15 4+1 29131723 102 [kg] 3) Effective volume as a function of inlet nozzle level H [mm] 10

Characteristic curves n = 3500 rpm, 60 Hz U60, U100, UZ150 17 16 0 50 US.gpm 100 150 0 20 IM.gpm 40 60 80 100 120 140 Qmin DN 80 Qmin 2 U2.60, U2.100, UZ2.150 14 12 H m 10 40 ft 8 6 20 4 2 1 0 5 Q m 3 /h 10 15 20 25 30 35 0 2 Q l/s 4 6 8 10 2 11

Dimensions and connections U (60 litres) DN 50 DN 50 DN 80/100 225 745* 455 3 450 180 100 50 20 340 2 C DN 50 DN 40 130 510 65 80 230 65 155 B 510 85 315 540 D A 1 85 Fig. 5: U (60 litres) connections and dimensions A Inlet B Inlet C Inlet /50 D Inlet DN 50 4) 1 Drain DN 40 2 Vent DN 50 3 Discharge line DN 80/100 * Length including gate valve 4) To prevent backflow, all sanitary appliances must be connected to the lifting unit with their pipe invert at least 180 mm above the tank floor. This connection is not suitable for discharge from shower basins. 12

U100 2 3 Example of U100 connections C D DN 70 A Fig. 6: Connections of U60/U100 A Inlet /100 B Inlet /100 C Inlet /100 D Inlet /100 1 Drain DN 40 2 Vent DN 70 3 Discharge pipe DN 80/100 B 1 500 DN 40 DN 80/ DN 80 UG1082118/Bl.1 Dimensions of U100 [mm] DN 70 DN 80/100 55 225 300 500 545 455 745 245 180 60 340 DN 40 180 705 60 115 305 95 760 110 345 215 50 240 35 115 690 UG1082118/Bl.2 685 For lifting units a working area of at least 600 mm width and height must be provided around and above all parts to be operated and serviced. UG1064780 745 = length including gate valve [mm] 13

U60, U100 Discharge pipe DN 80 Ø 83 - Ø 90 Ø 108 - Ø 115 180 200 X min. 30 max. 60 DN 80 Ø 83 Ø 108 X DN 80 U60, U100 Inlet pipe Gate valve made of grey cast iron Tank connection / 130 190 210 90 Gate valve made of PVC Tank connection / 60 70 180 225 60 70 14

UZ150 Connections of UZ150 3 2 D C A 1 Fig. 7: Connections of UZ150 A Inlet /100 B Inlet /50 C Inlet /100 D Inlet /100 1 Drain DN 40 2 Vent DN 70 3 Discharge pipe DN 80/100 B 500 DN 50 DN 40 DN 70 DN 80/ DN 80 UG1090423/Bl.1 Dimensions of UZ150 [mm] 550 20 DN 70 DN 80 DN 80 225 260 1005 300 500 455 55 340 DN 40 240 800 270 375 260 195 215 250 180 240 9 195 540 540 1080 1155 1075 UG1090423/Bl.2 215 For lifting units a working area of at least 600 mm width and height must be provided around and above all parts to be operated and serviced. DN 50 UG1074788 1005 = length including gate valve [mm] 15

UZ150 Discharge pipe DN 80 Ø 83 - Ø 90 Ø 108 - Ø 115 180 260 200 X min. 30 max. 60 DN 80 Ø 83 Ø 108 X DN 80 UZ150 Inlet pipe Gate valve made of grey cast iron Tank connection / 130 190 210 90 Gate valve made of PVC Tank connection / 60 70 180 225 60 70 16

Types of connection to a toilet U2.60 Connection to wall-mounted toilet bowl U2.100 Connection to wall-mounted toilet bowl 250 70 250 UG1081796 UG1081406 U2.60, U2.100 Connection to floor-mounted toilet bowl U2.60, U2.100 Pit installation 180 250 1) 2) 750 1) a 1000 2) UG1081297 UG1083681 17

Scope of supply example P14 P9.1/.2 P15 P8 P11 P3 P2 E1 (P8) P5 P4 P11 P10 P1 P14 P9.1/.2 P15 P18 P16 (P8) P5 P13 P2 P3 P11 P8 P6 P11 P4 E1 P10 P1 UG1078781 P18 P16 P6 UG1090407 mini-compactza UZ150 U60, U100 Inlet line Discharge line Variant 1 Variant 2 Variant 3 P3 P12 P11 P12 P8 P3 P3 Tank connection Tank connection /150 DN 80 Ø90 Variant 1 Variant 2 Ø108-114,3 P5 DN 80/80 P12 P5 DN 80/100 P13 UZ150 P12 DN 80 P12 P8 DN 80/100 P5 DN 80/100 P12 P8 /100 P9.1/.2 Variant 4 Tank connection /150 P11 DN 80 P12 P10 Supplied by operator P11 P3 P3 2317:401/2 UG1095524 Check valve Connections of U60, U100, UZ150 Connections of U60, U100, UZ150 Scope of supply of units Size Included in the scope of supply U60 U100 UZ150 P 1 P 1 P 1 Gas-tight, odour-tight, water-tight collecting tank made of impact-resistant plastic P 2 P 2 P 2 Fully floodable submersible motor pump P 3 P 3 P 3 Flexible hose connection and hose clips (inlet) P 4 P 4 P 4 Flexible hose connection and hose clips (venting) P 5 P 5 P 5 Flexible hose connection and hose clips for discharge line, consisting of stub flange DN 80/100, fabricreinforced rubber hose and adapter hose for outside pipe diameter of 108-114.3 mm 18

Size Included in the scope of supply U60 U100 UZ150 P 6 P 6 P 6 Flexible hose connection and hose clips (hand diaphragm pump) P 10 P 10 P 10 Check valve with full port and lifting screw - - P 13 5) Y-pipe DN 80 with 2 sets of installation accessories E 1 E 1 - Analog level sensor for pump and alarm buzzer - - E 1 Analog level sensor for pump 1, pump 2 and alarm buzzer; stand-by pump automatically starts up during peak loads E 3 6) E 3 6) E 3 6) Electronic control unit with integrated alarm circuit and charging circuit, with high-quality rechargeable battery and alarm buzzer Accessories Size Available as accessory U60 U100 UZ150 P 3 - P 3 Flexible hose connection and hose clips DN 50 - P 3 P 3 Flexible hose connection and hose clips P 5 P 5 P 5 Flexible hose connection and hose clips for discharge line, consisting of stub flange DN 80/80, fabricreinforced rubber hose and adapter hose for outside pipe diameter of 83-90 mm P 8 P 8 P 8 Stub flange Flanged socket (for connecting pipes made of ductile cast iron) P 9.1 P 9.1 P 9.1 for outside pipe diameter of 118 mm - P 9.1 P 9.1 for outside pipe diameter of 170 mm Flange adapter (for connecting pipes of different materials) P 9.2 P 9.2 P 9.2 for outside pipe diameter of 107.2-127.8 mm, L 105 mm - P 9.2 P 9.2 for outside pipe diameter of 158.2-181.6 mm, L 105 mm P 11 P 11 P 11 Gate valve P 12 P 12 P 12 Set of installation accessories - - P 13 Y-pipe DN 80, material variant C, with 2 sets of installation accessories P 14 P 14 P 14 Hand diaphragm pump ISO 7/l-Rp 1 1 / 2 P 15 P 15 P 15 Three-way plug valve ISO 7/l-Rp 1 1 / 2 P 16 P 16 P 16 Fully automatic drainage pump Ama-Drainer... with swing check valve SE/SD P 18 P 18 P 18 Cover plate A, 560 for 500 x 500 mm pits (for Ama-Drainer) E 50 6) E 50 6) E 50 6) AS 0 alarm switchgear E 51 6) E 51 6) E 51 6) AS 2 alarm switchgear E 52 6) E 52 6) E 52 6) AS 4 alarm switchgear E 53 6) E 53 6) E 53 6) AS 5 alarm switchgear E 64 6) E 64 6) E 64 6) F1 leakage sensor Connection nozzles Connection nozzles by model Inlet side Discharge side Vent Connection for hand diaphragm pump U2.60 Horizontal: 2 x, offset by 90, inlet nozzle level 180 mm, 1 x DN 50 vertical: 1 x /50, graded U2.100 Horizontal: 1 x /100, graded, inlet nozzle level 180 mm, 2 x /100, graded, inlet nozzle level 250 mm vertical: 1 x /100, graded UZ2.150 Horizontal: 1 x /100, graded, inlet nozzle level 180 mm, 1 x /50, graded, inlet nozzle level 250 mm, 1 x /100, graded, inlet nozzle level 250 mm vertical: 1 x /100, graded DN 80/100 Optionally DN 80/80 DN 80/100 Optionally DN 80/80 DN 80/100 (discharge line to Y-pipe ) Optionally: DN 80 DN 50 DN 40 (Rp 1 1 / 2 ) DN 70 DN 40 (Rp 1 1 / 2 ) DN 70 DN 40 (Rp 1 1 / 2 ) 5) Not for variant C 6) Not shown in drawing 19

Building Services: Drainage Control units and switchgear All switchgears and control units required for operation of the unit are included in the scope of supply. They feature an integrated acoustic alarm and volt-free signalling contact for transmitting fault messages to an alarm switchgear or directly to a control room. All switchgears and control units are supplied in enclosure IP54 and must be installed in a well-ventilated, floodproof room. LevelControl Basic 1 product description LevelControl Basic 2 product description Description Description Ready to be plugged in, with 1-metre power cable Ready to be plugged in, with 1-metre power cable Analog level detection with sensor monitoring Integrated master switch (LevelControl Basic 2 BS only) Manual-0-automatic selector switch Numerical display with status indication (traffic light) and navigation keys Acknowledgement button Indicator lamp for pump status Indicator lamp for high water Indicator lamp for rotary field (three-phase current only) Pump protection by thermal circuit breaker Input for external fault message General fault message or volt-free in operation message Integrated alarm buzzer Battery-backed mains-independent alarm Straightforward parameterisation of inlet nozzle levels via DIL switch during commissioning Fill level indication Indication of operating data Analog level detection with sensor monitoring Manual-0-automatic selector switch Indicator lamps Indicator lamp for high water Pump protection by thermal circuit breaker Integrated alarm buzzer Battery-backed mains-independent alarm Two inputs for external fault message and remote acknowledgement General fault message or volt-free "system operational" message Even distribution of pump operating hours due to automatic pump changeover Parameterisable service intervals Diagnostic and signalling/message functions Straightforward system configuration using parameterisation assistant (Wizard) Numerous additional functions (e.g. monitoring of supply voltage, measuring effective power, determining the power factor, intelligent system monitoring, and many more) 20

Combination of lifting and control units Combination of lifting units with LevelControl Basic 1 / Basic 2 Lifting unit Control unit Single-pump units U2.60 D LevelControl Basic 1 D U2.100 D LevelControl Basic 1 D Dual-pump units UZ2.150 D LevelControl Basic 2 ZD Special features of LevelControl Basic 1 Control unit LevelControl Basic D (CU 1 10 V T45 1 0 0 A D) Description Standard single-pump control unit for three-phase motor Three-phase connection Special features of LevelControl Basic 2 Control unit LevelControl Basic 2 ZD (BC2 400 DVNA 100 B0) Description Standard dual-pump control unit Three-phase connection 21

Accessories Lifting unit accessories Item Description Mat. No. [kg] P3 P5 Flexible hose connection (inlet) for inlet line, with fabric-reinforced hose and two hose clips ( included in the scope of supply) Flexible hose connection (discharge side) U60 U100 UZ150 DN 50-18040370 0,2 - - - 18040203 0,4-18040338 0,7 DN 80/65 19074057 7) 4,8 for discharge pipe, comprises fabric-reinforced hose, reducing nipple, connecting pipe, threaded flange DN 80 and hose clips Flexible hose connection DN 80/80 19070679 5,2 P8 for discharge line, with fabric-reinforced hose, adapter hose, stub flange made of steel, and hose clips Stub flange DN 65/65 19074058 7) 3,8 With hosetail, flanges drilled to PN 10/16, to EN 1092-1/2, plastic with spacer discs (DN 80/100), steel (DN 65/65, /100, /150) DN 80/100 18040303 0,4 DN 100/100 DN 150/150 19902512 4,5-19901562 9,1 P9.1 Flanged socket DIN 28 622, grey cast iron, flange drilled to PN 10/16, to EN 1092-1/2 for connecting pipes made of ductile cast iron for outside pipe diameter of 118 mm, for outside pipe diameter of 170 mm P9.2 Flange adapter Grey cast iron, for connecting pipes made of different materials 00262135 9,5-01020844 14,5 01070642 4,45-01070641 7,5 for outside pipe diameter of 107.2-127.8 mm, L = 105 mm P11 PVC gate valve PN 1 For inlet line with connection nozzle 01121715 3,5-01121714 9,2 P11 Gate valve to KSB's choice, PN 10 Grey cast iron, flanges drilled to PN 10/16, to EN 1092-1/2 DN 80 01056708 18,9 01056709 22,5-01056710 42,7 7) For the UK only 22

Item Description Mat. No. [kg] P12 Set of installation accessories for one flange connection made of steel or grey cast iron, with 8 hexagon head bolts with nuts and 1 gasket U60 U100 UZ150 DN 80 18072644 1 18060163 1,4-18076348 2 P13 Y-pipe grey cast iron (GG) with high-quality coating (Rilsan ), with 16 hexagon head bolts, nuts and 2 sealing elements DN 80 - - 8) 18041115 8 P14 Hand diaphragm pump, grey cast iron Rp 1 1/2 00520485 12 P15 Three-way plug valve Rp 1 1/2 19053063 1,5 Brass, with wrench WAF 22 P16/ P18 P20 For pumps that can be used in pump sumps, please refer to type series booklet Ama-Drainer N (reference number 2337.51) and/or Ama-Drainer. Blind flange Steel, for closing the tank when the pump assembly has been removed Blind flange Steel, for closing the pump casing when the rotating assembly has been removed - - 18040964 3,8 - - - 18040965 3,8 8) Only for material variant C 23

Building Services: Drainage Alarm switchgears for pumps without ATEX AS 0/AS 1/AS 2/AS 4/AS 5 Item E50 Description Alarm switchgearas 0 Mat. No. 29128401 [kg] 0,5 With circuit breaker, acoustic signal transmitter with 85 db(a), green equipment-on lamp E51 Plastic housing, IP20, H W D = 140 80 57 [mm]. Use float switch, F1 leakage sensor (item E64), M1 alarm contactor or signal relay of control unit as contactor. Alarm switchgearas 2 29128422 0,5 With circuit breaker, acoustic signal transmitter with 85 db(a), green equipment-on lamp, volt-free contact for hook-up to a control station E52 Plastic housing, IP20, H W D = 140 80 57 [mm]. Use float switch, F1 leakage sensor (item E64) or signal relay of control unit as contactor. Alarm switchgearas 4 29128442 0,5 With circuit breaker, acoustic signal transmitter with 85 db(a), green equipment-on lamp, volt-free contact for hook-up to a control station, self-charging power supply unit for 5 hours of operation in the event of a power failure E53 Plastic housing, IP20, H W D = 140 80 57 [mm]. Use float switch (E60), F1 leakage sensor (item E64) or signal relay of control unit as contactor. Alarm switchgearas 5 00530561 1,7 00533740 0,9 Mains-independent, with self-charging power supply unit for 10 hours of operation in the event of a power failure, mains pilot LED, fault indicator light, horn-off pushbutton, voltfree contact for hook-up to a control station, ready for connection with 1.8 m connection cable and plug. E55 ISO housing, IP41, H W D = 190 165 75 [mm]. Use float switch (E60) or signal relay of control unit as contactor. Alarm switchgearas 1 In IP30 ISO plug housing, mains-independent, with self-charging power supply unit for 5 hours of operation in the event of a power failure, acoustic signal transmitter 70 db(a) with circuit breaker and integrated signal transmitter with 3-metre connection cable, max. 60 C, not suitable for steam and condensate. 1. High water alert by suspending the moisture sensor in a (pump) sump above the pump start-up point. 2. Water alarm signal at a water level of only 1 mm (!), by placing the contactor on the floor of rooms at risk of flooding, e.g. the cellar or next to the washing machine in the kitchen or bathroom. 9) 10) 24 In combination with alarm switchgears AS 0, AS 2, AS 4 or LevelControl In combination with AS 5 or Level Control Basic 2

Control unit/switchgear accessories Item Description Mat. No. [kg] E64 F1 leakage sensor 9) 19072366 0,2 As contactor for alarm switchgears AS 0, AS 2, AS 4 or as alarm transmitter for LevelControl, with 3-metre power cable, max. 40 C, not suitable for steam and condensate Possible applications for alarm transmission: 1. High water alert by suspending the leakage sensor in a (pump) sump above the pump start-up point. 2. Water alarm signal at a water level of 1 mm (!) in areas at a leakage risk in the cellar or next to the washing machine in the kitchen or bathroom. H W D = 52 21 20 [mm] E70 Horn, 12 V DC, 105 db, 150 ma, IP54, with 0.45 m connection cable 10) 01086547 0,1 For indoor installation and outdoor installation, to be mounted in a position where it is protected from direct rain E71 Alarm combination (yellow alarm strobe light and piezo buzzer 92 db), 12 V DC, 120 ma, 01139930 0,1 IP65 10) E72 Yellow alarm strobe light, 12 V DC, 195 ma, IP65 10) 01056355 0,3 O45 Plastic housing, IP65, H W D = 55 82 106.5 [mm], for easier installation of alarm strobe light, for wall mounting 01061067 0,2 E73 PC service tool 47121210 0,2 E300 CD-ROM with instructions, dongle for authorisation, RS 232 parameterisation cable and USB/RS 232 adapter (for laptops without serial interface) to prevent parameterisation of the equipment by untrained personnel. The service software can also be used without a dongle. However, some parameters will be locked in this case. The dongle can only be used after it has been enabled by KSB. To this effect, follow the instructions included. Master switch, 32 A, external 01118354 0,4 E301 Plastic housing, IP65, H W D = 90 90 145 [mm] for LevelControl Master switch, 16 A, external 01212348 0,4 Plastic housing, IP65, H W D = 90 90 145 [mm] for LevelControl O200 Signalling module for LevelControl Basic 2, type BC 19075182 0,2 O203 Signalling module for LevelControl Basic 2, type BS 19075185 1,1 The control units LevelControl Basic 1 and LevelControl Basic 2 are fitted with a mains-independent acoustic alarm (buzzer) and a volt-free signalling contact for transmitting alarm signals in the case of a fault (e.g. to the control room). For this reason, alarm switchgear is not absolutely necessary, however, it can be used for setting off an acoustic alarm in building parts at a distance from the lifting unit in the case of a fault (e.g. lifting unit in the cellar, additional alarm switchgear in the hallway). 25

KSB Aktiengesellschaft Johann-Klein-Straße 9 67227 Frankenthal (Germany) Tel. +49 6233 86-0 www.ksb.com 2317.56/09-EN-EN 08/01/2018