POWER and INTELLIGENCE
|
|
- Virginia O’Connor’
- 6 years ago
- Views:
Transcription
1 POWER and INTELLIGENCE Lifting stations The new lifting station Aqualift F Compact - Sewage lifting station complete basement drainage installation in a slab/floor and free-standing installation Leading in drainage
2 Lifting station Aqualift F Compact installation in a slab/floor and free-standing installation wastewater with and without sewage Chamber ready underground installation Compact design makes installation particularly easy! The telescopic upper section makes flexible adaptation to the required installation depth possible available with extension section if required (Art # ). Upper section can be turned, tilted and freely height-adjusted. The pump seat is sound decoupled from the collecting tank. Integrated drain function The drain contained in the cover drains all surface water. Even in the event of a pipe burst or flooding, the pump discharges water out of the house and into the sewer. Installation in - gasket set protection from water load The compression seal flange in connection with the gasket set (art. no ) guarantees safe sealing against groundwater when the Aqualift F Compact is installed in. Aqualift F Compact slab/floor installation Aqualift F Compact free-standing installatio Installation in basement slab Install lifting station, connect supply pipes and pressure pipe. Set in, incl. gasket set Once the flooring has been completed R lifting station is invisible
3 n Maximum safety thanks to control unit with SDS The intelligent control unit with integrated self-diagnosis system SDS and battery buffering continually monitors all electric functions and keeps an electronic operating log which can be read out. If the pump is at a standstill longer periods, it is even put into operation briefly once a week. Max. pumping quantity Q (m 3 /h) Pumping height H (m) Tool free pump removal The backwater flap prevents the wastewater from backing up into the system renovation Thanks to its installation area of only 700 x 700 mm, the Aqualift F Compact can also be used in an existing pump sump. An acoustic insulation mat is included in the scope of supply. The free-standing model is delivered ready connection. Permance diagram underground and above-ground systems [m] [Qm 3 /h] powerful compact & reliable Wastewater station Aqualift F Compact Functions Lifting station underground and above-ground installation wastewater with and without sewage Draining function underground installation, including use after a pipe burst or flooding Chamber ready installation underground installation, also suitable installation in Application Can be used as a lifting station according to DIN EN wastewater with sewage. Cost advantage about 500 Aqualift F Compact underground installation is a complete ready-to-install system including chamber and height-adjustable cover. Being able to do without a pump chamber not only saves homeowners about 500, it is also a hygienic alternative to the conventional pump sump. Also suitable rooms used accommodation in the basement: Aqualift F Compact underground installation is equipped with a cover plate a selection of finishes. In combination with the drain grid that can be tiled over, the result is an almost invisible lifting station. Type of current Alternating current Voltage 230 V Curr - ent 4.9 A Motor capacity P1 / P W / 620 W Speed 2800 rpm Motor protection thermal in motor Operating mode S3-30% better like this......than like this!
4 Lifting station Aqualift F Compact installation in a slab/floor and free-standing installation Pressure Illustration and dimensional drawing Description Art. # conn. Units/ Box/Pack Installation set installation in slab/floor from von 70 to 180 bis 180 D T DN fl Ø Installation area 800 x 800 mm DA Ø Lifting station Aqualift F Compact Mono / Duo Lifting station wastewater with and without sewage underground installation / in a slab/floor, with tilable cover and drain With odour trap, water seal head 50 mm Single lifting station Twin lifting station Installation depth (D) from 486 to 600 mm With lateral inlet fl 110. With telescopic upper section free height and level adjustment, recessed cover on-site tiling, made of polymer class A15, with moisture protective sealing flange. With one or two removable pumps, with integrated backwater flap. With SDS control unit (self-diagnosis system) fully automatic pump control, splashwaterprotected (IP 54), wall mounted. Rated input: 1.0 kw. Pressure connection: 1 1/2" outer thread, pressure pipe fl 40 mm PVC glued connection or pressure pipe set (accessories, Art. # ) Pumping height: max. 9,5 m, Qmax = 10.9 m 3 /h Operating voltage: 230 V ~ 50 Hz. Electric supply cable: 5 m. A ventilation pipe must be provided on site. Approval pending / /- 207 DN fl 100 For free-standing installation 80 Ø DA fl Lifting station Aqualift F Compact Mono / Duo Lifting station wastewater with and without sewage free-standing installation For free-standing installation Single lifting station Twin lifting station With one or two removable pumps, with integrated backwater flap. With SDS control unit (self-diagnosis system) fully automatic pump control, splashwaterprotected (IP 54), wall mounted. Rated input: 1.0 kw. Pressure connection: 1 1/2" outer thread, pressure pipe fl 40 mm PVC glued connection or pressure pipe set (accessories, Art. # ) Pumping height: max. 9,5 m, Qmax = 10.9 m 3 /h Operating voltage: 230 V ~ 50 Hz. Electric supply cable: 5 m. Without non-return valve, with vertical pressure outlet A ventilation pipe must be provided on site. Approval pending DA /- DA /- Installation area 700 x 700 mm
5 Straightward installation, safe function, sophisticated look Installation example Backwater level Rückstaueben For complete basement drainage: KESSEL lifting station Aqualift F Compact Art. # Control unit Gasket set Art. # Pressure pipe set with flexible pressure hose Art. # Ventilation via roof * * Please note installation and operating instructions Accessories Illustration Description Ø Art. # Transition piece Ø 110 / 75 fl 110 socket / fl 75 spigot, can be used as connection piece, incl. seal Units/ Box/Pack 75/ /- Covers, resistant to surface water, Class A 15 with drain Ø 75 incl. Multistop recessed on-site tiling, grey, tile thickness up to 18 mm with integrated drain grate, black / /- Pressure pipe set incl. 5 m pressure hose Ø 40, adapter with pipe clamp Ø /- Extension section with flange made of polymer incl. seal, max. extension: 180 mm, to fit gasket set, Art # /14 Gasket set installation in Comprising: Counterflange made of polymer, incl. screws Elastomer membrane made of NK/SBR Ø 800 mm Audible alarm 20 m cable length suitable all control units with SDS function / /- Potential-free contact /-
6 For optimum protection: KESSEL premium backwater valves and lifting stations Rückstauebene Backwater level Do your drains have a gradient to the sewer? Rückstauebene Backwater level Are your drains below sewer level? then use KESSEL premium backwater valves then use KESSEL lifting stations 1 Do you have a toilet in the basement? Ecolift as cheap as a backwater valve, as safe as a lifting station. Ecolift uses the natural gradient to the sewer! Minimum energy consumption No pumping noises increased living comt No interruption in operation in the event of a power failure Integrated drain function...or secure your basement with the automatic backwater valve Staufix FKA or the backwater pumping station Pumpfix F. Ecolift Extra tip Sink, shower, washing machine: Dispose of your wastewater using the lifting station Aqualift S installed in a conrete slab/floor or the lifting station Minilift. Minilift free standing Minilift underground Do you have a toilet in the basement?...then pump your wastewater out using the lifting station Aqualift F, or the wastewater station Aqualift F Compact Aqualift S Especially suitable use in Staufix FKA Lifting station Aqualift F lifting station Aqualift F Compact 2 If all the pipes in the basement are routed into one collecting pipe and from there to the sewer......you can protect several draining elements in the basement centrally against backwater using the Staufix SWA. Staufix SWA Extra tip Outside buildings, you can use a KESSEL backwater chamber or a chamber with an Aqualift F lifting station as a single or twin system backwater protection 3 Sink, shower, washing machine, heating overflow: Secure the individual draining elements using Staufix fl 50 or fl 75 or Staufix Siphon fl 50. Staufix fl 50 and fl 75 Staufix Siphon fl 50 4 Floor drain: Use Drehfix or Universal protection. Water comes through the basement window: Extra tip Pumpfix S pumps the basement dry! Backwater chamber EN DIN EN Konmitätszertifikat Lifting station / pumping station in the Comt chamber system Find out about other KESSEL backwater protection products from your specialist dealer or visit Drehfix Universal Pumpfix S Rights reserved technical changes KA /CS 03/12 KESSEL AG Bahnhofstraße Lenting Germany export@kessel.de
74 Catalogue 3.1. Wastewater lifting stations
7 Catalogue. Wastewater lifting stations Wastewater lifting stations for wastewater containing raw sewage for free standing installation and for installation in a concrete floor Page 80 97 for underground
More information3 Wastewater lifting stations
Wastewater lifting stations for wastewater containing raw sewage for free standing installation and for installation in a concrete floor Page 66 8 for underground installation Page 9 0 for wastewater without
More informationKESSEL-Staufix FKA Backwater Valve
INSTALLATION AND USER S MANUAL NETZ SIGNAL RÜCKSTAU KLAPPE PRÜFEN KESSEL-Staufix FKA Backwater Valve Double flap backwater valve with motorized flap and manual closure lever Optical probe for backwater
More informationINSTALLATION AND OPERATING INSTRUCTIONS
INSTALLATION AND OPERATING INSTRUCTIONS KESSEL Grease Separator G, D and D+S versions Certified under Euro-Norm EN 1825-1 For free standing installation in frost free areas KESSEL Grease separators G,
More informationMULTISAN Fully automatic sewage and waste water pump
MULTISAN Fully automatic sewage and waste water pump Multisan is suitable for pumping waste water from toilets, bidets, showers and basins from rooms which are below the sewer level, or conditions where
More informationSekamatik series PREFABRICATED LIFTING STATIONS FOR RESIDENTIAL, COMMERCIAL OR INDUSTRIAL APPLICATIONS
Sekamatik series PREFABRICATED LIFTING STATIONS FOR RESIDENTIAL, COMMERCIAL OR INDUSTRIAL APPLICATIONS Wastewater is a demanding process, performance, day in day out. Xylem challenges, providing trusted
More informationLifting Plants Product Overview
Wilo-DrainLift Con Duty chart (-pole, 5 Hz) 5 Wilo-DrainLift Con Lifting Plants Product Overview Wilo-DrainLift Lifting Plants Condensate lifting plants Removal of condensate, can be used in Condensing
More informationKESSEL Grease separator M NG 2, 4, 7 and 10 For installation in frost free areas With manually automated disposal program
INSTALLATION AND OPERATING INSTRUCTIONS KESSEL Grease separator M NG 2, 4, 7 and 10 For installation in frost free areas With manually automated disposal program Version according to DIN 4040-1 or Version
More informationKESSEL Grease separator EasyClean free Standard, Direct - oval in NS 2, 4, 7, 10, 15, 20, 25, 30 for set-up in frost-free rooms
INSTRUCTIONS FOR INSTALLATION, OPERATION AND MAINTENANCE KESSEL Grease separator EasyClean free Standard, Direct - oval in NS 2, 4, 7, 10, 15, 20, 25, 30 for set-up in frost-free rooms GB Page 1-18 Product
More informationStainless Steel Sanitaryware
Stainless Steel Sanitaryware www.purusinternational.com Stainless Steel Sanitaryware At Purus you can find stainless steel sanitary products for your home as well as for public buildings. You can choose
More informationAutomatic Waste Water Lifting Unit. Ama-Drainer-Box Mini. Type Series Booklet
Automatic Waste Water Lifting Unit Type Series Booklet Legal information/copyright Type Series Booklet KSB Aktiengesellschaft Pegnitz All rights reserved. Contents provided herein must neither be distributed,
More informationDRAINAGE AND SEWAGE. DRENA-LINE Residential Technology
DRAINAGE AND SEWAGE DRENA-LINE Residential Technology 1 HIGH QUALITY IS OUR MISSION The Pentair Group is one of the world leaders in the design and manufacture of innovative products and systems used
More informationKESSEL Grease Separator Euro G NG 1, 2 and 4 For underground installation
INSTALLATION AND OPERATING INSTRUCTIONS KESSEL Grease Separator Euro G NG 1, 2 and 4 For underground installation KESSEL Grease Separator G according to EN 1825-1 NG 1,2, 4 - for underground installation
More informationAutomatic Waste Water Lifting Unit
Type Series Booklet 2331.55/4-EN Ama r -Drainer-Box 021 Automatic Waste Water Lifting Unit Above-floor-Box 021 Fields of Application Single Lifting Unit - Above-floor Box 021 F Automatic drainage of wash-basins,
More informationREMKO HYBRID HEAT PUMPS
REMKO HYBRID HEAT PUMPS Switch over to more efficiency even in old buildings HBW series 1-2014 Quality with systems THE HYBRID TECHNOLOGY Two technologies combined into one innovation "Hybrid comes from
More informationProcess engineering. Collection and disposal of commercial food waste ACO Waste-Jet Wet refuse collection system
Collection and disposal of commercial food waste ACO Waste-Jet Wet refuse collection system ACO. The future of drainage. The ACO system chain provides drainage solutions to meet tomorrow s environmental
More informationSafety vacuum drying oven for flammable solvents
VDL series 53 Vacuum drying ovens Safety vacuum drying oven for flammable solvents A BINDER safety vacuum drying oven of the VDL series ensures maximum safety when drying organic solvents standard with
More informationREMKO Comfort-WP The versatile heat pump
REMKO Comfort-WP The versatile heat pump Issue 2012 Independent from oil and gas Cosy heat in the winter A pleasant climate in the summer CMF Series 1-2014 Quality with systems REMKO THE CUSTOMER-ORIENTED
More informationmini-compacta Type Series Booklet
Floodable Sewage Lifting Unit 60 Hz Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,
More informationAirUnit. Installation instructions. mfh systems modern floor heating. Decentralised domestic ventilation
mfh systems modern floor heating AirUnit Decentralised domestic ventilation Installation instructions List of contents, Installation instructions Page 1. General information... 03 2. Function / planning
More informationTrusted Expertise in Domestic and Commercial Wastewater
Trusted Expertise in Domestic and Commercial Wastewater Any Project, Any Wastewater Application Wastewater poses a complex challenge, no matter whether it originates in a single house or a multifamily
More informationGRUNDFOS. Multilift PRODUCTS. MSS, M, MOG, MD, MLD, MDG and MD1/V
GRUNDFOS Multilift PRODUCTS MSS, M, MOG, MD, MLD, MDG and MD/V GRUNDFOS The Grundfos MULTILIFT is a compact, powerful lifting station that offers a complete wastewater solution for commercial buildings
More informationBoiling water heater HBE
Application areas Boiling water supply: > Offices > Canteens / Bistros > Restaurants / Hotels > Hospitals Product information 1 / 6 Product information boiling > 6-003 6-005 6-007 Part number [case painted
More informationOperation Manual. Time controlled condensate drain unit UFZ. 000_H_uf_UFZ_GB_R00_D011002
Time controlled condensate drain unit UFZ 000_H_uf_UFZ_GB_R00_D011002 ultramatic UFZ Angular plug Time control unit Valve Control panel Pressure side connection Screw-type conduit fitting with strain relief
More informationProduct Catalogue WB Engineering Containers. fast inexpensive safe flexible certified
Product Catalogue WB Engineering Containers fast inexpensive safe flexible certified Table of Content Product Catalogue Key data WBEC - Standard & Premium Key data WBEC - Standard model Key data WBEC Premium
More informationVacuum drying oven for non-flammable solvents
VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.
More informationBasement Pump & Drainage Catalogue
November 2016 Basement Pump & Drainage Catalogue The Waterproofing People [BPD-B-V1-11.16] 2016 Delta Membrane Systems Ltd. All rights reserved. Subject to modification without prior notice. CONTENTS 2
More informationLifting Station Type ABS Sanimax
1051-00 15970278EN (11/2015) EN Installation and Operating Instructions www.sulzer.com 2 Installation and Operating Instructions (Original Instructions) : R 202 MF 154 R 202/C MF 154HW MF 324 Contents
More informationLyovapor L-300 Technical data sheet
Lyovapor L-300 Technical data sheet With Infinite-Technology the Lyovapor L-300 offers continuous sublimation for the first time with two alternate working and automatically hygienically cleaned condensers
More informationRight-hand connection. 1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm
Hose and cable lengths depending on model Scope of delivery depending on model AquaäStop AquaäSecure or Left-hand connection ~ 100 cm ~ 145 cm ~ 145 cm ~ 95 cm Moisture inside the drum is due to final
More informationFlues and chimney systems
Flues and chimney systems Complete systems overview Table of content About us 02 Portfolio overview 03 Timeline 04 Gas flue systems 06 Chimney systems rigid single-wall 08 Chimney systems flexible single-wall
More information290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING
Fresh air boxes ALB Comfortable climate with pre-heated, filtered supply air. Ingeniously practical: Supply air, heating and filter in a single unit. For direct in-duct mounting. The fresh air boxes ALB
More informationDPU110. DPU110: Uncompromisingly functional
DPU110 Reversible Vibratory Plates DPU110: Uncompromisingly functional The most powerful vibratory plate with center pole on the market comes from Wacker Neuson - the specialist in matters of compaction.
More informationVD 53 - Vacuum drying oven for non-flammable solvents
Vacuum drying ovens VD 53 - Vacuum drying oven for non-flammable solvents The VD series offers safe drying with homogenous temperature distribution, thanks to its APT.line air jacket system. ptimum heat
More informationplumbing for greywater
plumbing for greywater october 2015 christina bertea ~union trained journeywoman plumber (1978) ~plumbing contractor (1996) ~greywater action singingwater@jps.net plumbing for greywater basic parts of
More informationPlugging Home Drains to Prevent Sewage Backup
NDSU EXTENSION SERVICE EXTENDING KNOWLEDGE CHANGING LIVES AE1476 (Reviewed May 2018) Plugging Home Drains to Prevent Sewage Backup Why plug drains For homes in areas of the country prone to flooding or
More informationGAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS. Spare parts suitable for GRANDIMPIANTI
GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS Spare parts suitable for GRANDIMPIANTI GRANDIMPIANTI heating elements/thermostats heating elements heater battery No. 4522
More informationcatalogue made in Germany Sanitary Installations Water Sewage Industry
catalogue made in Germany Sanitary Installations Water Sewage Industry move water. waste disposal companies Entsorgungsbetriebe Grease Seperators from PE NG 1-10 (even for surface installation) Page 35
More informationVentilation and extraction systems. A fresh breeze. with Marley ventilators, ventilation grilles and flat ductwork systems. Do it with Marley.
Ventilation and extraction systems A fresh breeze with Marley ventilators, ventilation grilles and flat ductwork systems Do it with Marley. So that it doesn t take our breath away Moisture-loving mildew
More informationContent. 1 Basics. 2 Detailed Information on different types of Vacuum technologies. Vacuum sanitary installations. Vacuum sewer systems
Vacuum Technology - collection and transport of sewage by means of low pressure Christine Werner, Florian Klingel, Ulrike Mosel, Sebastian Hass Deutsche Gesellschaft für Technische Zusammenarbeit (GTZ)
More informationHeated Gas Sampling Probe PSG Basic
Heated Gas Sampling Probe PSG Basic Application The heated gas sampling probes series PSG Basic are used for continuous extractive gas analysis. They enable troublefree representative sampling of hot predominantly
More informationOPERATION, INSTALLATION AND MAINTENANCE INSTRUCTIONS SERIES INTERCEPTORS
OPERATION, INSTALLATION AND MAINTENANCE INSTRUCTIONS 5400-5500 SERIES INTERCEPTORS 5401 75 4NH 5500 50 3IPS INSTALLATION Place the Wade interceptor downstream of the drain which will supply the oil laden
More informationSOLOLIFT2. Grundfos bring you a macerator that is the most powerful, reliable and service friendly on the market, delivered by a name you can trust
Grundfos bring you a macerator that is the most powerful, reliable and service friendly on the market, delivered by a name you can trust - GET INTRODUCED TO A NEW GENERATION Up until now, macerators have
More informationSanitary Drainage Systems
11.1 MATERIALS See Section 3.1. Sanitary Drainage Systems 11.2 BUILDING SEWERS AND BUILDING DRAINS 11.2.1 Sewer or Drain in Filled Ground Chapter 11 Building sewers or building drains that are installed
More informationCleaning System. Amajet. Type Series Booklet
Amajet Type Series Booklet Legal information/copyright Type Series Booklet Amajet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed
More informationBoiling water heater KA
Application areas Boiling water supply: > Offices > Canteens / Bistros > Restaurants / Hotels > Hospitals > Catering services Product information 1 / 7 Product information boiling > 15 25 40 Part number
More informationJUNG PUMPEN LIFTING STATIONS
JUNG PUMPEN LIFTING STATIONS POWERFUL AND DEPENDABLE RESIDENTIAL TECHNOLOGY LIFTING STATIONS Product overview: Lifting stations the full range: Lifting stations are designed to dispose of wastewater in
More informationSL EX.4.51D
GRUNDFOS DATA BOOKLET SL1.1.1.75.EX.4.51D Grundfos pump 962669 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/sl1/962669/sl1-1-1-75-ex-4-51d-c.html
More informationin/out connections outer Ø 25 bar (363 psi) 200 kg/h SS '000 (2.12 HP) 300 kg/h CU (661 lb/h) (3.18 HP) 300 kg/h SS (661 lb)
CO 2 Vaporising Atmospheric ASCO CO 2 Vaporiser The atmospheric ASCO CO 2 Vaporiser has been developed to drastically reduce CO 2 vaporisation costs. Ambient air, which is available at no cost, is used
More informationGrease separator. Chapter contents. Grease separator for freestanding. Separator. Grease separator
Chapter contents Separator for freestanding installation With complete disposal Mobile separator for food stall or marquee Basic design for disposal via the cover Extension stage 1 for disposal via direct
More informationGreenleaf 100 Toilet Macerator Waste Pump Instruction Manual
Greenleaf 100 Toilet Macerator Waste Pump Instruction Manual Website: Contact: www. greenleaftrade.co.nz Greenleaf 100 Macerator Toilet Pump System Grey Water Capable Introduction The Greenleaf 100 toilet
More informationData sheet: Wilo-RainSystem AF Comfort MC 304
Data sheet: Wilo-RainSystem AF Comfort MC 304 Pump curves Wilo-RainSystem AF Comfort H/m 50 Wilo-RainSystem AF Comfort Approved fluids (other fluids on request) Pure water without settling sediment Rainwater
More informationTechnical information SB 4 10/11 Prefabricated swimming pools -English-
Technical information SB 0/ Prefabricated swimming pools -English- M o u n t i n g o f e q u i p m e n t P r e fa b r i c at e d S w i m m i n g p o o l s. W h i r l p o o l s Content. Skimmer RG 6. Skimmer
More informationMicro/Ultra Filtration System StamoClean CAT 430
Technical Information TI 338C/07/en/10.03 No. 51508729 Micro/Ultra Filtration System StamoClean CAT 430 Long-term Stable Membrane Filter for Immersion Operation in Activated Sludge Basins or Wastewater
More informationProduct news 2018/19. Heat pump system WIKOSOL HPS. Tank for wall boiler WBO TN. Vacuum tube collector WIKOSUN HP 2340 / 1240
Product catalog 2019 Valid from 1st of April 2019 1 Product news 2018/19 Heat pump system WIKOSOL HPS Page 5 For the replacement and modernization of heaters in existing buildings Most powerful heat pump
More informationdp pumps the dynamics of water HVAC centrifugal (norm) pumps
dp pumps the dynamics of water HVAC centrifugal (norm) pumps 2 HVAC centrifugal (norm) pumps HVAC efficient solutions for comfortable living conditions To be comfortable in a building, both at home and
More informationcondensate pumps For air conditioning and refrigeration technology eckerle.com
condensate pumps For air conditioning and refrigeration technology eckerle.com Condensate pumps in air conditioning technology Condensation is the change of state of the physical state of matter from gas
More information1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm
Safety instructions The washing machine is heavy - take care when lifting. Caution: frozen hoses may rip/burst. Do not install the washing machine in areas exposed to frost or outdoors. The washing machine
More informationConnection parts and accessories
Kunststofftechnik GmbH Am Wingert 1-3 D-35428 Langgöns Telefon +49(0) 64 03 916-0 Telefax +49(0) 64 03 916-200 e-mail: info@truplast.com www.truplast.de www.truplast.com Kunststoff technik GmbH e r u s
More informationHL Anti-flooding valves 5/4" DN40 = DN32 = DN32 = DN40 = 280 DN32 DN32 = 350 DN40 DN40 = 350 DN32 = 90 DN40 = 95
5/4" DN40 = 80-315 DN32 = 80-315 DN40 = 350 DN32 = 350 DN40 = 280 DN32 = 285 29 DN40 DN32 HL Anti-flooding valves DN40 = 50-250 DN32 = 50-220 Basement and backflooding DN40 = 95 DN32 = 90 HL Hutterer &
More informationMinor Home Repairs. November 4, County of Henrico Department of Community Revitalization
Minor Home Repairs 1 November 4, 2017 County of Henrico Department of Community Revitalization Educate homeowners on basic technical skills that will help the homeowner understand daily operations of different
More informationControl unit PPT/RS,, Controls the functions of the conveyor. Fully pneumatic. The maximum recommended distance between the conveyor and contr
Control unit PPT/RS,, 0111636 Controls the functions of the conveyor. Fully pneumatic. The maximum recommended distance between the conveyor and control unit is 10 metres when feed pressure is 0.6 MPa.
More informationwww
HettCube INCubatORS AND COOLED INCubatORS sustainable. ERGONOMIC. HIGH QUALITY. www.hettichlab.com THE HettCube RANGE GET THE MOST OUT OF YOUR INCubatORS. ENVIRONMENTALLY FRIENDLY, ECONOMICAL AND WELL
More informationGRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions
GRUNDFOS INSTRUCTIONS Sololift2 C-3 Installation and operating instructions English (US) English (US) Installation and operating instructions Original installation and operating instructions. CONTENTS
More information1 Exam Prep Plumber s Handbook Tabs and Highlights
1 Exam Prep Plumber s Handbook Tabs and Highlights These 1 Exam Prep Tabs are based on the Plumber s Handbook Revised 2006. Each Tabs sheet has five rows of tabs. Start with the first tab at the first
More informationVacuum mixers Wamix-Classic and Wamix-Injector
Novelties 2012 Vacuum mixers Wamix-Classic and Wamix-Injector It s all in the mixing! Model production Wamix-Classic with accessory table stand Technical information Powerful, compact and innovative: The
More informationCompressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture
meas. according to ISO 8573 Residual oil content - particles - moisture DS 500 - the intelligent chart recorder of the next generation. The centerpiece of compressed air quality measurement is the chart
More informationGRUNDFOS ALLDOS DISINFECTION. ALLDOS DISINFECTION SYSTEMS with Chlorine Gas 1 GRUNDFOS ALLDOS DISINFECTION
GRUNDFOS ALLDOS DISINFECTION ALLDOS DISINFECTION SYSTEMS with Chlorine Gas 1 GRUNDFOS ALLDOS DISINFECTION Content Applications 4-5 Page Geco 103-100 compact dosing unit 1 Vacuum regulator and dosing unit
More informationSanitary & Hospital Equipment
Sanitary & Hospital Equipment Introduction With 40 years experience, M&G Olympic Products has maintained its position as a leading specialist in the design, manufacture and installation of custom built
More informationMODEL INSTALLATION INSTRUCTIONS GRINDER PUMP
www.burcam.com 2190 Dagenais Blvd. West LAVAL (QUEBEC) CANADA H7L 5X9 TEL: 514.337.4415 FAX: 514.337.4029 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping.
More informationACO Marine Advanced wastewater solutions for the marine and offshore market
ACO Marine Advanced wastewater solutions for the marine and offshore market ACO Marine environmental solutions for the marine and offshore market ACO Marine is a member of the international ACO Group
More informationdp pumps the dynamics of water HVAC centrifugal (norm) pumps
dp pumps the dynamics of water HVAC centrifugal (norm) pumps 2 HVAC centrifugal (norm) pumps HVAC efficient solutions for comfortable living conditions To be comfortable in a building, both at home and
More informationConstant climate chamber with humidity
KBF series (E5.2) Constant climate chambers Constant climate chamber with humidity The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climate
More informationPiggyback Mechanical Float Switch. Piggyback Vertical Mechanical Float Switch. Piggyback Diaphragm Switch. Accessories
Piggyback Mechanical Float Switch Piggyback Vertical Mechanical Float Switch Residential sewage waste transfer RFSN-6, RFSN-9 and RFSN-10 any manual pump, up through 3/4 convert any manual pump, up hp
More informationXpert HD Xpert HD 7140, ,
Xpert HD 7140 Cold-water pressure washer for daily commercial use. With its compact dimensions, robust construction and greatest possible manoeuvrability, this unit is a credit to the compact class. TECHNICAL
More informationSilvento concealed variant clamped-ventilator - Replaces Skalar-; Skalar-V...; Skalar-2V... - Installation directions - Please pass on to the user -
Silvento concealed variant clamped-ventilator - Replaces Skalar-; Skalar-V...; Skalar-2V... - Installation directions - Please pass on to the user - Contents: Notes on these installation instructions Safety
More informationPRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h
PRODUCT DATA COMFORT 40 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 40 m /h COMFORT 40 Product description The Comfort 40 is an energy-efficient ventilation
More informationThe right temperature worldwide NEW. Excellent price-performance ratio Compact design Simple to use. LAUDA Microcool. Circulation chillers
The right temperature worldwide Excellent price-performance ratio Compact design Simple to use NEW LAUDA Microcool Circulation chillers LAUDA Microcool Circulation chillers for reliable continuous operation
More informationGRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz
GRUNDFOS DATA BOOKLET Unilift CC, KP, AP Submersible drainage and effluent pumps 50 Hz Contents Product overview Unilift CC, KP, AP 3 General data Performance range 4 Applications 5 Examples of applications
More informationMicro/Ultra Filtration System StamoClean CAT 430
Technical Information TI 338C/07/en/11.01 No. 51508729 Micro/Ultra Filtration System StamoClean CAT 430 Long-term stable membrane filter for immersion operation in activated sludge basins or wastewater
More informationPLEXUS. Marine HVAC Components for Boats and Yachts CATALOGUE
PLEXUS Marine HVAC Components for Boats and Yachts CATALOGUE 08/2017 1 PLEXUS CATALOGUE 08/2017 Self Contained ASC MAP Series...2 Split ASP System ASP Series... 4 Water Chiller AWC Series - Single Chiller...
More informationMini fans MiniVent M1/100
Mini fans MiniVent M1/100 M1/100 Mini fans of highest quality. Design and performance of the MiniVent M1/100 sets the standard for the mini fans range. M1/100 Performance curve high speed The excellent
More informationK 5 Premium Home T 350
K 5 Premium Home T 350 The "K5 Home" with water-cooled motor and hose reel for ease of use. A high-pressure cleaner for moderate dirt. Including Home Kit (T 350, stone and facade cleaner). 1 2 3 4 1 2
More informationABS lifting station Sanimax
105100 15970278GB (09/2011) GB Installation and Operating Instructions www.absgroup.com Installation and Operating Instructions (Original Instructions) R202 R202/C MF154 MF324 Contents 1 General... 3 1.1
More informationCBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet
CBU144 Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717 Product specification sheet Version The Compact Booster Unit consists of the following modules, that
More informationConstant climate chambers
KBF series (E5.2) Constant climate chambers Constant climate chambers The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climatic conditions.
More informationConstant climate chambers
KBF series (E5.2) Constant climate chambers Constant climate chambers The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climatic conditions.
More informationDomestic fans. Circular duct fans 1. Rectangular duct fans 2. Roof fans 3. Axial fans 4. Smoke evacuation fans 5.
Domestic fans Circular duct fans Rectangular duct fans Roof fans xial fans Smoke evacuation fans TEX rated fans Corrosion resistant fans Domestic fans ccessories Wiring diagrams 0 Index Content Centrifugal
More informationUSING YOUR PRESSURE SEWER SYSTEM
USING YOUR PRESSURE SEWER SYSTEM A homeowner s manual About this manual This manual will assist you with the operation and maintenance of the pressure sewer system installed on your property. We strongly
More informationMultiplex drain/overflow Visign M5. Instructions for Use from 06/2015. en_int
Multiplex drain/overflow Visign M5 Instructions for Use Model Year built: 6162 from 06/2015 en_int Multiplex drain/overflow Visign M5 2 from 16 Table of contents Table of contents 1 About these instructions
More informationSheet Formers "Rapid Koethen" System
1/6 Sheet Formers "Rapid Koethen" System Type BB Sheet Former for Manual Operation The low-cost alternative with 1 to 4 Vacuum Dryer units. Provides manual control of the sheet forming and drying processes
More informationGAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS. Spare parts suitable for LA CIMBALI
GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS Spare parts suitable for LA CIMBALI LA CIMBALI heating elements heating elements heating elements for coffee machine No.
More informationProtected with TechCoat finish. For Ceramic Tile Showers Cast iron Threaded for test nipple Extra heavy (.050) strainer DRAIN CONNECTION
QUICK CONNECT SHOWER DRAIN Protected with TechCoat finish Quick Clamping Gasket And Collar For Ceramic Tile Showers Cast Iron Clamping collar securely attaches drain to drain line Speeds installation Extra
More informationSignal anodes and sacrificial anodes. Rainwater harvesting. Domestic water system centre. Water filters
Signal anodes and sacrificial anodes Rainwater harvesting Domestic water system centre Water filters CHAPTER Equipment for drinking water supply and rainwater harvesting OVERVIEW Equipment for drinking
More informationVersaFlow Coriolis 100 Mass Flow Sensor Technical Datasheet. Specification
VersaFlow Coriolis 100 Mass Flow Sensor Technical Datasheet 34-VF-03-09 29 TH May, 2009 Specification The universal solution for the process industry VERSAFLOW is the only sensor for mass flow in its class
More informationUser manual. Washing Machine ZWG K
EN User manual Washing Machine ZWG 71202 K Contents Safety information 2 Safety instructions 3 Environment concerns 4 Product description _ 5 Control panel _ 6 Washing programmes 7 Consumption values _
More informationWashing machine PW 6055 AV/LP PW 6065 AV/LP. en - GB. Installation plan
Installation plan Washing machine PW 6055 AV/LP PW 6065 AV/LP To avoid the risk of accidents or damage to the machine, it is essential to read operating and installation instructions before installation
More information2. All necessary storm and sanitary pumps shall be tied into emergency power, and sump levels shall be monitored electronically through the B.A.S.
DIVISION 22 00 00 22 30 00 EQUIPMENT Page 1 of 10 22 30 00 EQUIPMENT 22 01 01 GENERAL REQUIREMENTS General 1. All plumbing shall comply with the B.C. Plumbing Code. 1. Avoid the use of storm pumps and
More informationThe new SOLOLIFT2 means goodbye to dirty hands
The new means goodbye to dirty hands The new is generations ahead Compact lifting stations have suffered a bad reputation, but the new generation is here! Combining innovation with modern comfort, Grundfos
More informationGeberit Assisted Toilet Pre-Installation Instructions
140mm Geberit Assisted Toilet Pre-Installation Instructions Pre-Install Instructions Please see the below for instructions to prepare site for installation. All electrical connections are to be carried
More information