GRUNDFOS ALLDOS DISINFECTION. ALLDOS DISINFECTION SYSTEMS with Chlorine Gas 1 GRUNDFOS ALLDOS DISINFECTION

Size: px
Start display at page:

Download "GRUNDFOS ALLDOS DISINFECTION. ALLDOS DISINFECTION SYSTEMS with Chlorine Gas 1 GRUNDFOS ALLDOS DISINFECTION"

Transcription

1 GRUNDFOS ALLDOS DISINFECTION ALLDOS DISINFECTION SYSTEMS with Chlorine Gas 1 GRUNDFOS ALLDOS DISINFECTION

2 Content Applications 4-5 Page Geco compact dosing unit 1 Vacuum regulator and dosing unit in one device for direct mounting on a chlorine gas cylinder Complete with injector, vacuum line and spare sealings C 111/C 113 dosing system Continuous chlorine gas dosing without interrupting the process for manual or automatic control vacuum regulators for mounting on chlorine gas cylinders Dosing unit for separate wall mounting The first cylinder being empty, the U 189 device changes immediately over to the next vacuum regulator at the full chlorine cylinder C 117/GS 146 dosing system 8 Continuous gas dosing without interrupting the process for manual or automatic control 8b 8a 2 vacuum regulators for mounting 8 on gas drums, liquid traps avoid the penetration of liquefied gas Separate installation of several dosing units 7 7 If the first drum is empty, the device changes immediately over to the 13 next vacuum regulator at the full gas drum The safety valve avoids excess pressure in the vacuum lines leaving the dosing system Display unit for empty signal / Gas sensor Gas warning unit Gasdetect 4 Injector Flowmeter with current signal output 5 Vacuum change-over unit U Compact measuring system Conex Compact 6 Chlorine gas absorption cylinder Vacuum regulator with liquid trap 8 Dosing unit with manual rate valve 8a 8b Dosing unit with electric servomotor Dosing untit with electric servomotor and current input

3 GS 140 Series High capacity disinfection system These innovative disinfection sytems dispose of modern sensors and microprocessor electronics for the measurement of the chlorine concentration and the control of the dosing flow. A multitude of sensors offer in connection with PLC extensive possibilities of monitoring and early detection of faults in automated systems, and thus provide the utmost process safety. Structure Vacuum regulator with gas inlet valve and safety valve for installation in a gas tank room Dosing unit with flowmeter, linear adjustment valve and differential pressure controller for installation on the floor or at the wall Modern optional equipment for control, regulation, full-automatic operation and control Injectors especially developed for the new dosing system with utmost efficiency b 3b 3c 3c a 1a Accessories Change-over devices Chlorine header line Pressure reducing valve Injection Units Chlorine gas absorption cylinder Injectors Combined liquid chlorine trap Chlorine gas filter Drum support 1 Chlorine drum 5 Nitrogen flushing device 14 Chlorine gas sensor 1a Chlorine drum balance 6 Chlorine evaporator (Alldos safety system Gasdetect) 2 Control for the pneumatic chlorine 7 Pressure reducing valve and filter 15 Optical and acoustic alarm device drum quick-action stop valves 8 GS vacuum regulator 16 Suction nozzle to the chlorine gas 3 Chlorine drum lifting device 9 GS gas dosing system neutralization sytem 3a Lifting beam 10 High-capacity injector 17 Central control panel with computer 3b Spring balance for cranes 11 Motive water booster pump interface 3c Chain hoist 12 Flowmeter with 4-20 ma output 18 Sprinkling system 4 Automatic change-over device 13 Injection unit 3 GRUNDFOS ALLDOS DISINFECTION

4 Chlorine gas disinfection systems are used for drinking water treatment.

5 Applications Chlorine gas disinfection systems can be used for various purposes: Drinking water The most important application area for gas disinfection systems is in the drinking water sector, including the disinfection of raw water as well as the final disinfection after treatment process. Pool water disinfection Every swimmer adds to microorganisms to the water. The water itself contains microorganisms, as well. Chlorine gas is the effective and economic means for the disinfection of swimming pool water. Process water disinfection Chlorine gas can also be used for disinfection of process water to ensure that microbial contamination transmission from water is minimized. Cooling water treatment By disinfecting the cooling water you remove microorganisms that can affect the system. Waste water disinfection Waste water disinfection includes disinfection of industrial waste water and municipal waste water. It protects the public from potential exposure to pathogenic microorganisms that would otherwise be present in wastewater. 5 GRUNDFOS ALLDOS DISINFECTION

6 GECO compact dosing unit max ca Technical data Medium Chlorine gas Capacity range g/h, g/h, g/h, g/h, g/h, g/h, g/h Adjustment ratio 1 : 20 Accuracy +/- 4 % Measuring device According to the floater principle, measuring tube 70 mm Empty indication Optical signal for lack of chlorine, automatic Materials Enclosure PVC Inlet valve Silver/PTFE, special alloy Springs Hastelloy C coated Diaphragm FEP Rate valve PVC O-rings Viton B Yoke Cast, nickel plated Connections Pressure gas USA yoke, option: union nut Vacuum safety line PE hose 8/11 Injector water connections ¾ hose / ¾ NPT up to 1000 g/h 1 hose / 1 NPT up to 2000 g/h 1 ¼ hose / 1 ¼ NPT up to 4000 g/h P max (water) Motive water pressure at the injector: 16 bar Backpressure at the injector outlet: 5 bar Weight 1,3 up to 2 kg Geco variants Capacity Injector connection g/h ¾ hose / ¾ NPT g/h g/h g/h g/h 1 hose / 1 NPT g/h 1 ¼ hose / 1 ¼ NPT g/h Optional connections Union nut 1 Union nut G 5/8 Union nut G ¾ Optional accessories Manometer 0-16 bar, NG 63 Residual pressure control 2 bar Liquid trap, heating 230 V, cable with Euro plug Measurements in mm

7 C 111/C 113 dosing system This systems consists of Vacuum regulator C Single dosing regulator C or 390 Vacuum regulator C Connection Capacity union nut 1 max. 4 kg/h 31.4 C with manometer With inlet valve and safety overpressure valve Prepared for manometer Optical empty indication 25 m of vacuum line (PE hose 8/11) with connections With gaskets for cylinder connection Optional connections Union nut G 5/8 Union nut G 3/4 Union nut 1,03-14 Union nut 1 ¼ USA yoke Optional accessories Manometer 0-16 bar, NG 63 with or without Min contact output Residual pressure control 2 bar Liquid trap, heating 230 V, cable with Euro plug Liquid trap, heating 115 V, cable with USA plug Vacuum regulator for serial installation Testing agents for tightness check C with liquid trap Single dosing regulator C /390 Capacity 2-40 g/h g/h g/h g/h g/h g/h g/h g/h 400 For operation with vacuum regulator With compensation regulator and measuring device 10 m of vacuum line (PE hose 8/11) Fixing material included Dosing regulator C with electric servomotor C C Synchronous motor with limit switches, IP 55 enclosure Actuating time (0-100%): 109 s at 50 Hz, 87 s at 60 Hz Power consumption: 3 VA Standard: mains voltage of servomotor 230 V (50/60 Hz) Option: mains voltage 115 V - please indicate separately Option : different measuring range (please see tabel below) with servomotor with 4-20 ma input for proption control, manual/automatic switch, trimmer for zero point/limit value, keys for manual control open/close Measurements in mm 7 GRUNDFOS ALLDOS DISINFECTION

8 2 vom Vakuumregler from vacuum regulator du règulateur de dèpression zum Injektor to injector vers hydro-ejecteur C117/GS 146 dosing system Ø 6 Ø 6 This systems consists of Vacuum regulator GS Single dosing regulator C or 190 Dosing regulator C Capacity 0,5-10 g/h g/h g/h g/h g/h g/h g/h Dosing regulator C Ø Dosing regulator with servomotor For the operation with vacuum regulator Mounted on a plate for wall mounting With manual rate valve and measuring device Vacuum connection for PE hose or PVC pipe Dosing regulator C Capacity 0,5-10 g/h B Synchronous motor with limit switches, enclosure IP 55 Actuating time (0-100%): 108 s at 50 Hz, 87 s at 60 Hz Power consumption: 3 VA Standard: mains voltage servomotor 230 V (50/60 Hz) Options: mains voltage 115 V please indicate separately Option: different measuring range with servomotor 4-20 ma input for proportional control, manual/automatic switch, trimmer for zero point/limit value, keys for manual open/close Cl 20 C bar abs ALLDOS A Vacuum regulator GS Connection Capacity Dosing regulator C Ø PE 10/ union nut 1 max. 10 kg/h With inlet valve and safety overpressure valve Overpressure connection for PE hose 8/11 Optional connection Union nut 1 Union nut G 5/8 Union nut G ¾ Union nut 1,03-14 Union nut 1 ¼ USA yoke Ø Optional accessories Plate for wall mounting, incl. fixing material Manometer 0-16 bar, NG 63 Manometer 0-16 bar, NG 63, with Min contact output Liquid trap, heating 230 V, cable with Euro plug Liquid trap, heating 115 V, cable with USA plug GS Different vacuum connection for the dosing unit - optional Connection for PE hose 10/14 Connection for PE hose 12/16 Connection for PVC pipe 12/16 Connection for PVC pipe 15/20 Measurements in mm

9 GS 140 Series This systems consists of Vacuum regulator GS 146, 147 or 148 Dosing regulator GS 141, 143 or 145 Additional accessories / /50 Ø 175 GS DN DN 40=730 DN 20= GS with foot for floor mounting Ø / GS 148 DN 25 Vacuum regulator GS 146 and 148 GS for wall mounting Technical data for line installation, with integrated safety valve, with grooved flange 1 DN 25 (G1 ), without liquid trap Chlorine gas Ammonia Sulphur dioxide Flow rate Vacuum connection Order No. Flow rate Vacuum connection Order No. Flow rate Vacuum connection Type No. max. 40 kg/h PVC pipe 20/ max. 20 kg/h PVC pipe 20/ N max. 38 kg/h PVC pipe 20/ S max. 70 kg/h PVC pipe 40/ max. 35 kg/h PVC pipe 40/ N max. 65 kg/h PVC pipe 40/ S max. 120 kg/h PVC pipe 40/ max. 60 kg/h PVC pipe 40/ N max. 115 kg/h PVC pipe 40/ S max. 200 kg/h PVC pipe 40/ max. 100 kg/h PVC pipe 40/ N max. 190 kg/h PVC pipe 40/ S Manometer for Cl 2, 0-16 bar, NG 63, optionally with MIN contact (N.O./N.C.) without manometer, optionally prepared for pressure sensor Testing agents bottle with ammonia for tightness check (Cl 2, SO 2 ) sulphur strips for tightness check (NH 3 ) System types Vacuum dosing system with rate valve Gas flowmeter according to floater principle Vacuum meter NG 100 mm Manual adjustment of the dosing flow Differential pressure regulator Floor mounting unit, covered Measurements in mm 9 GRUNDFOS ALLDOS DISINFECTION

10 Dosing regulator GS 141/143/145 Chlorine gas (Cl 2 ) Dosing capacity Vacuum connections Type No g/h g/h g/h g/h g/h g/h 0,5-10 kg/h 1-20 kg/h 2-40 kg/h 3,5-70 kg/h kg/h kg/h PE hose 10/ PVC pipe 20/ PVC pipe 40/ Gas dosing system GS Optional servomotor synchronous motor 3VA, IP 55, actuating time 0-100%: 90s at 50 Hz, 75 s at 60 Hz, installed on the rate valve 230 V (50/60 Hz), input/output 4-20 ma 115 V (50/60 Hz), input/output 4-20 ma Vacuum meter for injector vacuum NG 100 with 2 limit contact outputs Dosing system without vacuum meter Pressure sensors For injector vacuum For operating vacuum 2 pressure sensors (for injector and operating vacuum), signal evaluation via external PLC, required control voltage 24 V Enclosure versions Floor mounting unit with hood, open foot wall mounting unit with hood Optional vacuum connections (only GS 141) for PE hose 8/11, PE hose 12/16, PE hose ½, PVC pipe 12/16, PVC pipe 15/20 Chlorine gas disinfection systems ensure constant quality of your swimming pool water.

11 Accessories Vacuum change-over device U Change-over device U D Vacuum change-over device U H Ø 6.5 D1 262 Vacuum change-over device U 189 L D1 For combining 2 vacuum regulators with dosing regulators, vacuum connection PE hose 8/11 up to 4 kg/h, 10/14 up to 10 kg/h. 493 Option Additionally with 2 Reed contacts for remote transmission of the empty signal, max. 50 V/1 A/50 W Accessories empty signal Description Order No. Display unit for empty signal, 115 V Display unit for empty signal, 230 V Wall mounting enclosure for display unit Change-over device U Technical data Connection PVC tube 32/40 Maximum flow up to 120 kg/h for Cl 2 up to 60 kg/h for NH 3 up to 115 kg/h for SO 2 Connections PVC tube 32/40 PVC tube 40/50, extensions PVC tube 20/25, reductions Mains voltage control panel 115 V or 230 V (50/60 Hz) Fastening material for wall mounting Labelling of the control panel German, English, French or Spanish Servomotor protection: IP 65 actuating time 0-100%: 4 seconds adm. ambient temperature: 0 to +40 C adm. storage temperature: -10 to +50 C weight: 2 kg Control panel protection: IP 54 weight: 8,5 kg Technical data Nominal pressure Testing pressure 1170 Vacuum change-over device U bar 23 bar Connection inlet groove flange DN 25 (G1 )/PN 16, to DIN 2527/2512 Connection outlet tongue flange DN 25 (G1 )/PN 16, to DIN 2527/2512 Material valve body and flanges: steel valve balls: stainless steel gaskets: PTFE, glass-fiber reinforced lines: seamless drawn steel tube to DIN 2448 Protection IP 65 Actuating time 0-100% Outputs Power consumption Weight Admiss. ambient temperature 11 sec. at 50 Hz 9 sec. at 60 Hz 3 potential-free outputs; max. charge: 250 V AC, 10 A / 250 V DC, 1 A 0,1 kw 185-1: approx. 20 kg 185-2: approx. 30 kg 0 to + 40 C (Cl 2 + NH 2 ) + 10 to + 40 C (SO 2 ) Measurements in mm 11 GRUNDFOS ALLDOS DISINFECTION

12 Chlorine header line 542 Lacquered steel header line acc. to DIN 2441, flexible copper lines and connection valves Connection threads 1 (standard cylinder ) G 3/4 G 5/8 1,03-14 M 26x3 1 ¼ (standard drums ) for closed yoke (USA, 1,03-14) for open yoke (France, M 26x3) 15/16-8RH For cylinders 1 C B Pressure reducing valve 544 Technical data Nomin. pressure Backpressure Max. flow/ Medium Nominal diameter 16 bar adjustable at 2-3 bar (Cl 2 ); at 3-4 bar (NH 3 ) No. of cylinders Connections Servomotor Order No. 40 kg/h Cl 2 DN 15 G ½ kg/h NH 3 DN 15 G ½ kg/h Cl 2 DN 25 G kg/h NH 3 DN 25 G kg/h Cl 2 DN 15 G ½ x kg/h NH 3 DN 15 G ½ x kg/h Cl 2 DN 25 G 1 x kg/h NH 3 DN 25 G 1 x H Header line 542 for cylinders Part No. 111 without liquid 111 with liquid trap trap ~35 D L 1 T 1 T 2 L 2 For drums L G 1": L=160 ½ G ": L= H 162 Pressure reducing valves 544 Accessories for pressure reducing valves No. of drums Header line 542 for drums Collector pipe G ½ Collector pipe G 1 Cl 2 NH 3 + SO 2 Cl Description Order No. Manometer 0 to 16 bar, G ¼ (for Cl 2 ) Manometer 0 to 16 bar, G ¼ (for NH 3 ) Wall mounting bracket, steel Connection set for copper pipe 6/8 (G ½ Cl 2 ) Connection set for st. steel pipe 6/8 (G ½ NH 3 ) Pair of threaded flanges (connection flange), groove and tongue, DN 15 Pair of threaded flanges (counterflange), groove and tongue, DN 15 Pair of threaded flanges (connection flange), groove and tongue, DN 25 Pair of threaded flanges (counterflange), groove and tongue, DN Measurements in mm

13 Injection units /-252 Injectors for C 111/C 113 Material / Shut-off valve PVC / ball valve steel / diaphragm valve Connection chlorine solution line Installation connection Order No. PVC pipe 20/25 G PVC pipe 25/32 G 1 ¼ PVC pip 32/40 G flange DN 25 G 1 ½ flange DN 32 G 1 ½ flange DN 50 flange DN flange DN 65 flange DN flange DN 80 flange DN flange DN 100 flange DN flange DN 125 flange DN With non-return diaphragm FEP diaphragm PTFE piston PFFE coated spring Water connections for PVC pipe 20/25 Vacuum connection for PE hose 8/11 Technical data / Order data Max. capacity (g/h) Water flow (l/h) Adm. press. (bar) Backpress. (bar) Order No. Cl R D d D l L Injection unit /-252 Injector 3/ / / Injector / / A Chlorine gas absorption cylinder PVC, connection for PE tube 8/11, 5l content, filled with 4 kg absorbent, absorption capacity 450 g Cl 2, including fixing accessories The refilling granulate has the order no Measurements in mm 13 GRUNDFOS ALLDOS DISINFECTION

14 Injectors for C 117/GS 146 Variant: different vacuum connection Connection for PE hose 10/14 Connection for PE hose 12/16 Connection for PVC pipe 12/16 Connection for PVC pipe 15/20 A d D DN 20 Injector 1 ¼ / Technical data / Order data Max. capacity (g/h) Water quantity (l/h) Adm. pressure (bar) Backpressure (bar) Part Number Measurements d D A Water connections ¾ hose / ¾ NPT, vacuum connection 8/ ¾ hose ¾ NPT 400 Water connections 1 hose / 1 NPT, vacuum connection 8/ hose 1 NPT , Water connections 1 ¼ hose / 1 ¼ NPT, vacuum connection 8/ ,5-6, , , , , ¼ hose 1 ¼ NPT , , , , Injectors for GS Systems Technical data / Order data for Cl 2 max. operating pressure: 6 bar injectors for NH 3 and SO 2 on request Dosing capacity Cl 2 Counter pressure bar Length L (mm) Height H (mm) Connection motive water D1 Vacuum connection D2 Connection chlorine solution D1 Order No. 10 kg/h 0, PVC pipe 25/32 PE hose 10/14 PVC pipe 25/ kg/h 0, hose NPT 1 ¼ PE hose ½ hose NPT 1 ¼ kg/h PVC pipe 25/32 PE hose 10/14 PVC pipe 25/ kg/h hose NPT 1 ¼ PE hose ½ hose NPT 1 ¼ kg/h 0, PVC pipe 32/40 PVC pipe 20/25 PVC pipe 32/ kg/h PVC pipe 32/40 PVC pipe 20/25 PVC pipe 32/ kg/h 0, PVC pipe 50/63 PVC pipe 20/25 PVC pipe 50/ kg/h PVC pipe 50/63 PVC pipe 20/25 PVC pipe 50/ kg/h 0, PVC pipe 65/75 PVC pipe 40/50 PVC pipe 65/ kg/h PVC pipe 65/75 PVC pipe 40/50 PVC pipe 65/ kg/h 0, PVC pipe 80/90 PVC pipe 40/50 PVC pipe 80/ kg/h PVC pipe 80/90 PVC pipe 40/50 PVC pipe 80/ kg/h 0, PVC pipe 90/110 PVC pipe 40/50 PVC pipe 90/ kg/h PVC pipe 90/110 PVC pipe 40/50 PVC pipe 90/

15 Combined liquid chlorine trap and chlorine gas filter LiquFilt 524 steel vessel filled with chlorineproof rock-wool heater strip Separates the liquid chlorine parts from the chlorine gas flow and cleans the gas from impurities 490 ~ Drum support Order data Drum support set of two units for storate of one drum material: drum size: load: weight: accessories: Chlorine cylinder balance mounting plate: steel, laquered rollers, axles: steel, nickel-plated min. 0.7 m, max m max kg 2 x 23 kg fastening screws, heavy-load dowels Type No. 1 cylinder Type No Type No. 2 cylinders without empty indication with Reed contact for empty indication without output signal 4-20 ma Ø 96 Technical data Max. flow Nominal pressure Test pressure Material Input 200 kg/h Cl 2 (gaseous) 16 bar 23 bar high-grade seamless steel, Rockwool gasket material asbestos-free groove flange DN 25 (G 1 ), DIN 2527/2512 min M16 Ø Output tongue flange DN 25 (G 1 ), DIN 2527/ Weight 22 kg 650 Order data Description Type No. LiquFilt trap and filter, heater strip 115 V (50/60 Hz) Drum support Neutralisation Plant 15 GRUNDFOS ALLDOS DISINFECTION

16 Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence Being responsible is our foundation. We know that we have a responsibilty towards the people who are Grundfos, towards the innovation soul of Grundfos as well as towards the surrounding world. Whatever we do, we make sure that we have a firm and sustainable basis for doing it. Thinking ahead makes the innovations possible. We encourage a certain Grundfos way of thinking which is founded upon the belief that everyone must contribute by using his or her judgement and foresight. We are looking for commitment and ideas in everything we do in order to make the best solutions. We think - and we act. Innovation is the essence. It is the innovations that make Grundfos unique. We stand out because of our ability to constantly create new solutions to the ever-changing demands of the pump business. We meet every challenge and we are never afraid of taking the initiative - remainin gtrue to our ideals calls for renewal. Innovation is the soul of Grundfos.

Wallace & Tiernan Gas Feed Systems V2000 Chlorinator

Wallace & Tiernan Gas Feed Systems V2000 Chlorinator Wallace & Tiernan Gas Feed Systems V2000 Chlorinator Introduction Siemens Water Technologies chlorination equipment has the benefit of 100 years of experience in gas feed technology. V2000 chlorinators

More information

Oxiperm C 164 Fully automatic chlorine dioxide processing plant C, -6000C, -7500C, C. Service manual. Oxiperm 164C 4-10 kg Service en

Oxiperm C 164 Fully automatic chlorine dioxide processing plant C, -6000C, -7500C, C. Service manual. Oxiperm 164C 4-10 kg Service en Oxiperm 164C 4-10 kg Service en Oxiperm C 164 Fully automatic chlorine dioxide processing plant 164-4000C, -6000C, -7500C, -10000C Service manual 15.710138-V2.0 1 Imprint Oxiperm C 164 Fully automatic

More information

in/out connections outer Ø 25 bar (363 psi) 200 kg/h SS '000 (2.12 HP) 300 kg/h CU (661 lb/h) (3.18 HP) 300 kg/h SS (661 lb)

in/out connections outer Ø 25 bar (363 psi) 200 kg/h SS '000 (2.12 HP) 300 kg/h CU (661 lb/h) (3.18 HP) 300 kg/h SS (661 lb) CO 2 Vaporising Atmospheric ASCO CO 2 Vaporiser The atmospheric ASCO CO 2 Vaporiser has been developed to drastically reduce CO 2 vaporisation costs. Ambient air, which is available at no cost, is used

More information

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet CBU144 Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717 Product specification sheet Version The Compact Booster Unit consists of the following modules, that

More information

Capital Controls SERIES 70CV3000 CHLOROMATIC VALVE

Capital Controls SERIES 70CV3000 CHLOROMATIC VALVE Capital Controls SERIES 70CV3000 CHLOROMATIC VALVE Integrated Gas Control Valve with Integral Controller The Series 70CV3000 Chloromatic Intelligent Gas Flow Control Valve is designed to control chemical

More information

Safety vacuum drying oven for flammable solvents

Safety vacuum drying oven for flammable solvents VDL series 53 Vacuum drying ovens Safety vacuum drying oven for flammable solvents A BINDER safety vacuum drying oven of the VDL series ensures maximum safety when drying organic solvents standard with

More information

Advanced Technology for Superior Protection

Advanced Technology for Superior Protection Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence Grundfos FIRE SYSTEMS > BE Being responsible is our foundation. We know that we have a responsibility towards

More information

CAPITAL CONTROLS SERIES WP70CV3 GAS FEEDERS

CAPITAL CONTROLS SERIES WP70CV3 GAS FEEDERS CAPITAL CONTROLS SERIES WP70CV3 GAS FEEDERS The Capital Controls Series WP70CV3 gas feeders are wall panel mounted and vacuum operated. Easy to install, each Series WP70CV3 wall panel feeder is factory

More information

GLUE PUMPS. for Labelling Machines NEW MODEL ADVANTAGES: hoseproof IP66 programmable NFC-enabled

GLUE PUMPS. for Labelling Machines NEW MODEL ADVANTAGES: hoseproof IP66 programmable NFC-enabled 2015 GLUE PUMPS for Labelling Machines NEW MODEL 2015 ADVANTAGES: hoseproof IP66 programmable NFC-enabled Timmer GmbH Dieselstraße 37 D-48485 Neuenkirchen Tel.: +49 5973 9493-0 Fax: +49 5973 9493-90 www.timmer.de

More information

www.severntrentservices.com CAPITAL CONTROLS Series 70CV3000 Chloromatic TM Intelligent Gas Flow Control Valve The Series 70CV3000 Chloromatic TM Intelligent Gas Flow Control Valve is designed to control

More information

System Components and Accessories for Sample Gas Conditioning. Data Sheet 10/ EN June 2004

System Components and Accessories for Sample Gas Conditioning. Data Sheet 10/ EN June 2004 System Components and Accessories for Sample Gas Conditioning Data Sheet 0/3-5.0 EN June 004 Vol.% A gas analysis system usually consists of two groups of devices: The gas analyzer measures the concentrations

More information

Vacuum drying oven for non-flammable solvents

Vacuum drying oven for non-flammable solvents VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.

More information

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 The XB is a brazed plate heat exchanger designed for use with district heating systems (i.e. air conditioning,

More information

Table of contents: Chapter V. V. Disinfection systems DOSADes

Table of contents: Chapter V. V. Disinfection systems DOSADes Table of contents: Chapter V V. Disinfection systems DOSADes 5.1 Chlorine dioxide systems... 439 5.1.1 DOSADes Chlorine Dioxide Unit DOSAiX 8... 441 5.1.2 DOSADes Chlorine Dioxide Unit DOSAiXD 5 30...

More information

Heat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min

Heat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min Heat on Air heaters from 400 Watt to 17 400 Watt Blowers from 1,45 m 3 /min to 16,5 m 3 /min BAK Thermoplastic Need-to-know Calculation of air heaters 1. Heat requirement calculation Formula: Q = m * c

More information

Oil burners fuel unit with solenoid valve

Oil burners fuel unit with solenoid valve Oil burners fuel unit with solenoid valve Type VM www.deltapumps.com VM1 - VM4U flanged Certified Quality System Printed in Germany VM_e.pdf - 18.05.08 Page 1/6 Oil burners fuel unit with solenoid valve

More information

9.0 Systems For Domestic Water Installations

9.0 Systems For Domestic Water Installations 9.0 Systems For Domestic Water Installations 9.0.1Equipment Catalogue 2009 9.0.1 Proportional Flow Dosing System For Liquid Dosing turbodos, DULCODOS metering systems protect pipework, fittings, and devices

More information

Wallace & Tiernan Controllers & Analysers ChemTrim Disinfection Controller

Wallace & Tiernan Controllers & Analysers ChemTrim Disinfection Controller Wallace & Tiernan s & Analysers ChemTrim Disinfection Introduction The ChemTrim Disinfection is a modern, dedicated controller incorporating the latest advanced electronics and process control application

More information

PRODUCT LINE. Highest Quality, Best Service

PRODUCT LINE. Highest Quality, Best Service PRODUCT LINE Highest Quality, Best Service Manufacturing chlorination equipment and related products since 1978 PROUDLY MADE IN USA 600 Emlen Way, Telford, PA 18969 Telephone: (215) 799-0980 Fax: (215)

More information

VACUUM HEATING AND DRYING OVENS Gentle and safe

VACUUM HEATING AND DRYING OVENS Gentle and safe VACUUM HEATING AND DRYING OVENS Gentle and safe Quality Products Lifetime Care VACUTHERM 6000 USER FRIENDLY AS NEVER BEFORE The intelligent, modular system: three sizes and two types of heating Series

More information

Water temperature LBX 3 LBX 33: recommended range 5-25 C (41 77 F) LBX 90e LBX 1500e: recommended range 5-45 C ( F)

Water temperature LBX 3 LBX 33: recommended range 5-25 C (41 77 F) LBX 90e LBX 1500e: recommended range 5-45 C ( F) Main Applications Disinfection of effluents with low or highly variable UV transmittance: Biologically treated waste water Process water for industrial use Specific drinking water qualities Water temperature

More information

2 OZONFILT And Bono Zon Ozone Plants

2 OZONFILT And Bono Zon Ozone Plants 2.3.1 OZONFILT Ozone Production Plants OZVa 1-4 (Operating Gas - Air) Under nominal conditions, the OZVa 1-4 range produces up to 40 g/h of ozone from oxygen in the surrounding air at a concentration of

More information

HYGROPHIL H process hygrometer

HYGROPHIL H process hygrometer HYGROPHIL H 4230-10 process hygrometer Continuous humidity measurement in industrial processes. For very high demands in terms of being resistant to corrosion and dirt. Particularly suitable for cases

More information

Instruction Manual - Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity

Instruction Manual - Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity - Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity 100 PPD (2 kg/h) Chlorine or Sulfur Dioxide 250 & 500 PPD (5 & 10 kg/h) Chlorine or Sulfur Dioxide Anti-Siphon Ejector

More information

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25) Data sheet Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25) Description STW871 The controllers are: - Type-tested acc. to EN 14597 and protect against exceeding temperatures:

More information

Manual. Above-counter dispenser for hot drinks OTHG /12

Manual. Above-counter dispenser for hot drinks OTHG /12 Manual Above-counter dispenser for hot drinks OTHG 105 1 It is in your own interests to observe all the hazard and safety information. This helps you to prevent accidents and technical malfunctions. Only

More information

CAPITAL CONTROLS SERIES 480

CAPITAL CONTROLS SERIES 480 CAPITAL CONTROLS SERIES 480 All vacuum gas feeders designed for manual or semi-automatic gas regulation. The Capital Controls Series 480 all-vacuum gas feeder is designed for direct mounting to a 150 pound

More information

Capital Controls Series 480 All vacuum gas feeders designed for manual or semi-automatic gas regulation.

Capital Controls Series 480 All vacuum gas feeders designed for manual or semi-automatic gas regulation. Capital Controls Series 480 All vacuum gas feeders designed for manual or semi-automatic gas regulation. The Capital Controls Series 480 all-vacuum gas feeder is designed for direct mounting to a 150 pound

More information

Oil burners fuel unit with solenoid valve

Oil burners fuel unit with solenoid valve Oil burners fuel unit with solenoid valve Type VM www.deltapumps.com VM1 - VM4U flanged Certified Quality System Printed in Italy - DE112/0404 Oil burners fuel unit with solenoid valve Type VM The DELTA

More information

VD 53 - Vacuum drying oven for non-flammable solvents

VD 53 - Vacuum drying oven for non-flammable solvents Vacuum drying ovens VD 53 - Vacuum drying oven for non-flammable solvents The VD series offers safe drying with homogenous temperature distribution, thanks to its APT.line air jacket system. ptimum heat

More information

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Data sheet Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 IHPT The XB is a brazed plate heat exchanger designed for use with district heating systems

More information

WDT Service Instruction GRANUDOS 45/100 (V62PB-04-06) page 1 of 1. Series No...Customer...Date of delivery. Operating instructions GRANUDOS 45/100-PB

WDT Service Instruction GRANUDOS 45/100 (V62PB-04-06) page 1 of 1. Series No...Customer...Date of delivery. Operating instructions GRANUDOS 45/100-PB WDT Service Instruction GRANUDOS 45/100 (V62PB-04-06) page 1 of 1 Series No...Customer...Date of delivery. Operating instructions GRANUDOS 45/100-PB Safety Devices 1. Chlorine and acid may not be mixed

More information

NEOTeCHA Reactor Sampling Type PV

NEOTeCHA Reactor Sampling Type PV A safe and reliable sampling device to meet the demands of the chemical and pharmaceutical industry Features General applications To take a sample from reactors or vessels containing: poisoned media s

More information

Wallace & Tiernan Liquid Feed System LVN-2000 Liquid V-Notch

Wallace & Tiernan Liquid Feed System LVN-2000 Liquid V-Notch Wallace & Tiernan Liquid Feed System LVN-2000 Liquid V-Notch Overview continues to be the leader in the chemical feed and disinfection of potable water, wastewater and industrial process applications.

More information

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Catalog. Self-operated Regulators Volume 2 Temperature Regulators Catalog Self-operated Regulators Volume 2 Temperature Regulators Self-operated Regulators Temperature Regulators Volume 2 Catalog 2012 Overview Self-operated Temperature Regulators 5 Self-operated Pressure

More information

Technology for life. Unit heater LH

Technology for life. Unit heater LH Technology for life. Unit heater 1 2 Contents Contents... Page Basic unit: casing, fan, motors... 4 Basic unit: heat exchanger... 5 Performance tables 25...6-7 Performance tables 40...8-9 Performance tables

More information

WALLACE & TIERNAN CONTROLLERS & ANALYSERS CHEMTRIM DISINFECTION CONTROLLER PRODUCT SHEET

WALLACE & TIERNAN CONTROLLERS & ANALYSERS CHEMTRIM DISINFECTION CONTROLLER PRODUCT SHEET WALLACE & TIERNAN CONTROLLERS & ANALYSERS CHEMTRIM DISINFECTION CONTROLLER PRODUCT SHEET INTRODUCTION The ChemTrim Disinfection Controller is a modern, dedicated controller incorporating the latest advanced

More information

OEM Sensors for HVAC manufacturers Heat recovery Chiller

OEM Sensors for HVAC manufacturers Heat recovery Chiller OEM Sensors for HVAC manufacturers Heat recovery Chiller 2 Heat recovery / Chiller Typical magnetic-inductive flow sensor application Product features For determining the energy balance Measurement signal

More information

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A cod. 6272262A GENERAL DATA Heating Data Heat Output Input (Adjustable) (Adjustable) Format 34i 11.2 34KW 45 145MJ/hr Format 34e 11.2 34KW 45 145MJ/hr General Specifications FORMAT 34i 34e Main burner injectors

More information

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Data sheet Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 IHPT The XB is a brazed plate heat exchanger designed for use with district heating systems

More information

BINDER Scientific Product Catalog

BINDER Scientific Product Catalog BINDER Scientific Product Catalog 36 Vacuum drying ovens Vacuum drying ovens 37 VD VDL VDL EX-Zone 2 Absolutely reliable drying Drying with no residues, no danger of incrustation, no oxidation all under

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS KESSEL Grease Separator G, D and D+S versions Certified under Euro-Norm EN 1825-1 For free standing installation in frost free areas KESSEL Grease separators G,

More information

Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40

Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40 Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40 Application Instrument designed to measure and indicate differential pressure or measured variables derived from it For gases or liquids

More information

Thermostatic expansion valves for ammonia Type TEA

Thermostatic expansion valves for ammonia Type TEA Data sheet Thermostatic expansion valves for ammonia Type TEA Thermostatic expansion valves regulate the injection of refrigerant liquid into evaporators. Injection is controlled by the refrigerant superheat.

More information

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids Instrumentation for fluids Target Flowmeter Series DP-65 DP-500 Flow measurement of Gases and Liquids Metallic construction. Operates horizontally or vertically DN-80 to DN-500 Flow rate: - Water: 1.5

More information

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids UK / Europe Office Tel: +44 (0)8700 434040 Fax: +44 (0)8700 434045 info@omniinstruments.co.uk www.omniinstruments.co.uk Australia / Asia Pacific Office Tel +61 (0)282 442 363 Fax +61 (0)294 751 278 info@omniinstruments.com.au

More information

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50 Differential Pressure and Flow Meter Media 5 Indicator 160 Ø PN 50 Application Transmitter for measuring and indicating the differential pressure or measured variables derived from it Suitable for gases

More information

Micro/Ultra Filtration System StamoClean CAT 430

Micro/Ultra Filtration System StamoClean CAT 430 Technical Information TI 338C/07/en/10.03 No. 51508729 Micro/Ultra Filtration System StamoClean CAT 430 Long-term Stable Membrane Filter for Immersion Operation in Activated Sludge Basins or Wastewater

More information

Suction Controller SDR

Suction Controller SDR MB 00 / Constant suction pressure and leakage stop The suction controllers SDR 0 and SDR 00 have been developed because the flow rate of diaphragm metering pumps can be affected - among other factors -

More information

TECHNICAL SPECIFICATIONS FOR PLUSHER WDC 8 SERIES INSTRUMENT WASHER DISINFECTORS

TECHNICAL SPECIFICATIONS FOR PLUSHER WDC 8 SERIES INSTRUMENT WASHER DISINFECTORS TECHNICAL SPECIFICATIONS FOR PLUSHER WDC 8 SERIES INSTRUMENT WASHER DISINFECTORS PRODUCT PLUSHER WDC 8 series instrument washer disinfectors are offered in single door formation with manual horizontal

More information

~256. Ventilator. Float valve. Plugged end (INLET) Straight connection DN kpa: 1.20 l/s (instantaneous value)

~256. Ventilator. Float valve. Plugged end (INLET) Straight connection DN kpa: 1.20 l/s (instantaneous value) Date: 05 May 2009 Doc. 002190-2 TECHNICAL DATA 6543521 UNIT 2L, CONNECTION UPWARDS Mini-check Straight connection DN50 Rubber bend DN40 Connection DN40 83 ~195 35 Max. 3m ~256 Ø90 Evac Noback OUTLET Discharge

More information

TECHNICAL SPECIFICATIONS FOR PLUSHER WDS 18 SERIES INSTRUMENT WASHER DISINFECTORS

TECHNICAL SPECIFICATIONS FOR PLUSHER WDS 18 SERIES INSTRUMENT WASHER DISINFECTORS TECHNICAL SPECIFICATIONS FOR PLUSHER WDS 18 SERIES INSTRUMENT WASHER DISINFECTORS PRODUCT PLUSHER WDS 18 series instrument washer disinfectors are offered with single or double door formation with vertical

More information

WDT Operating Instruction GRANUDOS 45/100-S41 (11/05) page 1 of 1. Series No...Customer...Date of delivery. Operating instructions GRANUDOS 45/100-S4

WDT Operating Instruction GRANUDOS 45/100-S41 (11/05) page 1 of 1. Series No...Customer...Date of delivery. Operating instructions GRANUDOS 45/100-S4 WDT Operating Instruction GRANUDOS 45/100-S41 (11/05) page 1 of 1 Series No...Customer...Date of delivery. Operating instructions GRANUDOS 45/100-S4 Safety Devices 1. Chlorine and acid may not be mixed

More information

TARGET GROUPS MANUFACTURERS OF RUBBER AND PLASTIC MOULDED PARTS. Cryogenic media-blast deflashing Cryogenic drum deflashing Washing and drying systems

TARGET GROUPS MANUFACTURERS OF RUBBER AND PLASTIC MOULDED PARTS. Cryogenic media-blast deflashing Cryogenic drum deflashing Washing and drying systems TARGET GROUPS MANUFACTURERS OF RUBBER AND PLASTIC MOULDED PARTS www.awtechnik.de YOU KNOW THE REQUIREMENTS You yourself know best what you need in order to optimise your production processes as well as

More information

Short Path Distillation Unit. KDL 1 BASIC Version 2015

Short Path Distillation Unit. KDL 1 BASIC Version 2015 Short Path Distillation Unit KDL 1 BASIC Version 2015 Example Picture of KDL 1 BASIC with Option B, C, D and E 1/5 1. General This specification decribes the scope of delivery regarding a single stage

More information

TECHNICAL SPECIFICATIONS FOR PLUSHER WDS 12 SERIES INSTRUMENT WASHER DISINFECTORS

TECHNICAL SPECIFICATIONS FOR PLUSHER WDS 12 SERIES INSTRUMENT WASHER DISINFECTORS TECHNICAL SPECIFICATIONS FOR PLUSHER WDS 12 SERIES INSTRUMENT WASHER DISINFECTORS PRODUCT PLUSHER WDS 12 series instrument washer disinfectors are offered with single or double door formation with manual

More information

Control unit PPT/RS,, Controls the functions of the conveyor. Fully pneumatic. The maximum recommended distance between the conveyor and contr

Control unit PPT/RS,, Controls the functions of the conveyor. Fully pneumatic. The maximum recommended distance between the conveyor and contr Control unit PPT/RS,, 0111636 Controls the functions of the conveyor. Fully pneumatic. The maximum recommended distance between the conveyor and control unit is 10 metres when feed pressure is 0.6 MPa.

More information

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw The RL/1 burners series covers a firing range from 107 to 398 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Optimisation

More information

Condensate Monitor CGKW. Operator s Manual 42/23-36 EN Rev. 2

Condensate Monitor CGKW. Operator s Manual 42/23-36 EN Rev. 2 Condensate Monitor CGKW Operator s Manual 42/23-36 EN Rev. 2 Parts Supplied with the Unit Qty. Description 1 Mounting bracket 2 Nozzles G1/4 2 O-rings for nozzles 25 Filter membranes (of glass fibre) Examples

More information

Temperature controller for steam (PN 25) AVT / VGS - external thread

Temperature controller for steam (PN 25) AVT / VGS - external thread Data sheet Temperature controller for steam (PN 25) AVT / VGS - external thread Description The controller has a control valve VGS, thermostatic actuator and handle for temperature setting. Thermostatic

More information

Gas cooler series TC-Standard+ X2

Gas cooler series TC-Standard+ X2 Gas Analysis Gas cooler series In emission measurement, process control relies on prompt and exact determination of the operating parameters. Here, gas analysis is the key for safe and efficient control

More information

Constant climate chambers

Constant climate chambers Constant climate chambers KBF 115 (E2) - Constant climate chamber The KBF series was particularly designed for absolutely reliable stability tests and precise maintenance of constant climatic conditions.

More information

WOLF VENTILATION SYSTEM PRICE LIST

WOLF VENTILATION SYSTEM PRICE LIST VENTILATION SYSTEM PRICE LIST JANUARY 2018 30m 3 /h THE EXTENSIVE EQUIPMENT RANGE from system supplier WOLF offers the ideal solution for commercial and industrial buildings, new build and modernisation

More information

Hand pump JP-02. Hand pump JP-02 for acids, alkalies and water-based chemicals. depending on lever position. The telescopic suction tube is adjustable

Hand pump JP-02. Hand pump JP-02 for acids, alkalies and water-based chemicals. depending on lever position. The telescopic suction tube is adjustable Hand pump JP-02 Hand pump JP-02 for acids, alkalies and water-based chemicals Shaft: Stainless steel 316 Ti Seals: Viton Flow rate: 0,3, 0,37 or 0,45 l/stroke* depending on lever position from 340 to 900

More information

All All kin kin ds of Co t n r t ol V ol V v al es v Self-Actu Act a u ti a ng ng e Pr ss e ur ss e R egu e R

All All kin kin ds of Co t n r t ol V ol V v al es v Self-Actu Act a u ti a ng ng e Pr ss e ur ss e R egu e R All kinds of Control Valves Self-Actuating Pressure Regulators Pneumatic Actuators, Desuperheaters Smart Valves Welcome to the Art of Control Valves Technology International West Technology Transfer Co.

More information

CIRCO 6 Solar Circulation Unit

CIRCO 6 Solar Circulation Unit TECHNICAL INFORMATION / INSTALLATION INSTRUCTIONS CIRCO Solar Circulation Unit CIRCO Solar Circulation Unit in combination with the intelligent SUNGO controllers, it is the safe and reliable heart of a

More information

Gas cooler series TC-Standard+

Gas cooler series TC-Standard+ Gas Analysis Gas cooler series In emission measurement, process control relies on prompt and exact determination of the operating parameters. Here, gas analysis is the key for safe and efficient control

More information

Enraf Servo Gauge 854 XTG

Enraf Servo Gauge 854 XTG Enraf Servo Gauge 854 XTG Cut costs, not repeatability. Honeywell s 854 XTG servo gauge is a high performance alternative to other tank level measurement technologies such as radar tank level gauges. It

More information

Operating instructions

Operating instructions Operating instructions This handbook assumes that the reader and/ or operator is competent in the operation of chemical dosing systems and fully understands the inherent risks associated with the handling

More information

HERZ Differential Pressure Control Valve 4002

HERZ Differential Pressure Control Valve 4002 HERZ Differential Pressure Control Valve 4002 Data sheet 4002, Issue 0118 Dimensions in mm B1 B2 1 4002 41 1 4002 61 1 4002 71 1 4002 42 1 4002 62 1 4002 72 1 4002 43 1 4002 63 1 4002 73 1 4002 44 1 4002

More information

Vibratory and Centrifugal Surface Finishing Machinery and Systems

Vibratory and Centrifugal Surface Finishing Machinery and Systems Finishing For The World Vibratory and Centrifugal Surface Finishing Machinery and Systems Round and Trough Vibratory Machines Continuous and Linked Automation Systems Centrifugal Disc Finishing Machines

More information

SILOXA FAKA Gas Cleaning System

SILOXA FAKA Gas Cleaning System 1/6 Activated carbon adsorber for removing siloxanes and, if required, hydrogen sulphide (H 2 S) from sewage gas SILOXA s FAKA gas cleaning systems are highly efficient systems that are available in different

More information

The Meibes concept for the specialist: Easier. Quicker. More successful.

The Meibes concept for the specialist: Easier. Quicker. More successful. P R I C E L I S T 3 5 V A L I D F R O M 0 1. 0 1. 2 0 1 0...for the professional installer The Meibes concept for the specialist: Easier. Quicker. More successful. Easier Complete pre-assembled modules

More information

Cold water HD 9/18-4 ST

Cold water HD 9/18-4 ST Cold water HD 9/18-4 ST The space-saving stationary high-pressure cleaners from Kärcher with up to 6 supply points can be individually configured according to requirements and impress with low wear and

More information

Air. Pressure. Motion. nnnnnnnn

Air. Pressure. Motion. nnnnnnnn Air. Pressure. Motion. nnnnnnnn AIRTEC classic ejectors Page 10.001 AIRTEC column ejectors Vacuum generators with 1, 4, 6 and 8 independent vacuum circuits. Series HV and HF Page 10.010 MI and MIF Page

More information

Karlsruher Glastechnisches Werk KGW-ISOTHERM

Karlsruher Glastechnisches Werk KGW-ISOTHERM Karlsruher Glastechnisches Werk KGW-ISOTHERM Germany 76185 Karlsruhe Gablonzer Straße 6 Tel. 0049 / 721 / 95897-0 Fax. 0049 / 721 / 95897-77 E-Mail: info@kgw-isotherm.de Internet: kgw-isotherm.com Operating

More information

MagMaster MFE flowmeters feature an innovative multifrequency

MagMaster MFE flowmeters feature an innovative multifrequency INDUSTRIAL INSTRUMENTS AND CONTROLS SPECIALIST Kent-Taylor MagMaster MFE Series Flowmeters Electromagnetic Sensors Features Include Unrivalled flow performance- ±0.2% accuracy. Pulsed DC Technology Incorporates

More information

SIMRAD GD10 IR GAS DETECTOR

SIMRAD GD10 IR GAS DETECTOR 1 SIMRAD GD10 IR GAS DETECTOR Operating Manual 5th Edition P3359E October 1999 1 CONTENTS Section Page 1. PRODUCT DESCRIPTION 3 1.1 General description 3 1.2 Construction 3 1.3 Application areas 4 1.4

More information

541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P.

541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P. 541D19 SERIES Technical Manual A Division of Aquion Partners L.P. Table of Contents Introduction... Page 1 Technical Specifications... Page 2 Flow Diagrams... Page 3 Injector & Flow Control Selection Injector...

More information

Priming Aids ASH and AHP

Priming Aids ASH and AHP MB 1 33 01 / 1 What happens during priming? All types of metering pumps with low flow rates per stroke often haven priming problems which grow as the suction lift and the liquid density increase. Low flow

More information

Chlorine gas leak detector

Chlorine gas leak detector INSTRUCTION MANUAL FOR Chlorine gas leak detector with battery back up series M 4510 C 2007 Controlmatik ABW d.o.o. 1 CONTENT 1.0 General description:... 3 2.0 The Unit... 4 3.0 Controls and Displays...

More information

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature 1 882 1882P01 Symaro Duct Sensors for relative humitidy (high accuracy) and temperature QFM31 Use Examples Operating voltage AC 24 V / DC 1353 Signal output DC 010 V / 4 20 ma for relative humidity and

More information

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature 1 858 1858P01 1858P02 1859P02 Symaro Room Sensors for relative humidity (high accuracy) and temperature AQF3150 QFA31 Use Operating voltage AC 24 V / DC 1353 Signal output DC 010 V / 4 20 ma for r h and

More information

OPTISENS TUR 2000 Technical Datasheet

OPTISENS TUR 2000 Technical Datasheet OPTISENS TUR 2000 Technical Datasheet Sensor for turbidity measurement in water and wastewater Rugged design for harsh applications Integrated transmitter with direct 4...20 ma output Near infrared light

More information

Operation manual SOL-TEC - SL

Operation manual SOL-TEC - SL Operation manual SOL-TEC-SL (02-12) page 1 of 18 Operation manual SOL-TEC - SL Dosing station for the fine nebulisation of brine solution for dry rooms, e.g. Tepidariums to create a salty sea climate in

More information

Section K CHLORINATION EQUIPMENT

Section K CHLORINATION EQUIPMENT Section K CHLORINATION EQUIPMENT PART 1 GENERAL 1.01 SECTION INCLUDES A. Furnish and install chlorination equipment and appurtenances necessary to complete work shown or specified. The equipment is to

More information

Beck. The differential pressure transmitter for air

Beck. The differential pressure transmitter for air Beck. The differential pressure transmitter for air Differential pressure transmitter 984 General description The differential pressure transmitters of the 984 series are used to measure differential pressure,

More information

Electronic flushing and pressure testing unit with oil-free compressor. REMS Multi-Push EN ZVSHK 1) DVGW 2) for Professionals

Electronic flushing and pressure testing unit with oil-free compressor. REMS Multi-Push EN ZVSHK 1) DVGW 2) for Professionals Electronic flushing and pressure testing unit with oil-free compressor. REMS Multi-Push EN 806-4 ZVSHK 1) DVGW 2) for Professionals Only one device with more than 10 automatic programs for flushing, disinfection,

More information

PolyRex polymer make-up unit, vacuum conveyor support Technical specification

PolyRex polymer make-up unit, vacuum conveyor support Technical specification PolyRex polymer make-up unit, vacuum conveyor support Technical specification BASIC MACHINE DESIGN: Machine capacity: Max. preparation capacity at 0,5 % or 0,25% stock solution concentration and 60-45

More information

SIMRAD GD10PE IR GAS DETECTOR

SIMRAD GD10PE IR GAS DETECTOR SIMRAD GD10PE IR GAS DETECTOR Operating Manual P3404E 1st edition Jan. 2004 www.simrad-optronics.com CONTENTS 1. PRODUCT DESCRIPTION... 5 1.1 General description... 5 1.2 Construction... 5 1.3 Application

More information

4.Metering Pumps CONSTRUCTIONS. CR-N Series CRA-N Series: servo control model. CRP-N Series

4.Metering Pumps CONSTRUCTIONS. CR-N Series CRA-N Series: servo control model. CRP-N Series 4.Metering Pumps ELEPON FEEDER CR-N and CRM Series are designed as the direct-motion diaphragm injection pumps as safe and multipurpose pumps and also low-cast pumps. These pumps are used as the injection

More information

Constant climate chambers

Constant climate chambers Constant climate chambers KBF P 240 (E2) - Constant climate chamber for photostability tests Specialized equipment for photostability tests. Integrated cooling of fans consistently compensates for the

More information

Concise catalogue Water-Industry

Concise catalogue Water-Industry 2008 Concise catalogue Water-Industry One-channel instruments to measure ph, EC, DO and free chlorine, panel and wall-mounting version. Transmitters - controllers very easy to utilize, the customer does

More information

VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 500 l capacity

VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 500 l capacity VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 0 l capacity Datasheet Part no. and prices: see pricelist VITOCELL 300-V Type EVA and EVI Vertical DHW cylinder made from stainless steel 5/2012 Product

More information

Excellent performance with low operating costs, Energy saving and environmentally friendly

Excellent performance with low operating costs, Energy saving and environmentally friendly BOGE compressed air centre C 20 LDR 350 air cooled Screw compressor with BOGE energy saving refrigerant compressed air dryer on horizontal compressed air receivers Complete and ready to connect, fully

More information

Safety Laboratory Gas Burner. - A step ahead! Technical Data: The range of delivery:

Safety Laboratory Gas Burner. - A step ahead! Technical Data: The range of delivery: - A step ahead! The innovative SCS - Series provides maximum safety and highest convenience for all flame-related applications in the laboratory. Quality down to the smallest detail The unique quality

More information

Krypton K CL2. Measuring and control system for free chlorine. applications. description. Low maintenance by automatic sensor cleaning

Krypton K CL2. Measuring and control system for free chlorine. applications. description. Low maintenance by automatic sensor cleaning Low maintenance by automatic sensor cleaning Pressure-proof up to 6 bar at 20 C Higher safety by integrated flow monitoring applications Drinking Water / Beverages Food Industry Disinfection Cooling And

More information

rml Retractable CIP Spray Nozzles Manual Manual Installation, Operating and Commissioning ORIGINAL FILE

rml Retractable CIP Spray Nozzles Manual Manual Installation, Operating and Commissioning ORIGINAL FILE rml Retractable CIP Spray Nozzles Manual Manual Installation, Operating and Commissioning Date : 17 December 2013 Author : VJD Approval : VJD 1 ORIGINAL FILE Contents rml Retractable Spray Nozzle 1 Introduction...

More information

Hennecke description of day tanks and metering equipment used in conjunction with Rotamats supplied to Trane (Vidalia, GA)

Hennecke description of day tanks and metering equipment used in conjunction with Rotamats supplied to Trane (Vidalia, GA) Hennecke description of day tanks and metering equipment used in conjunction with Rotamats supplied to Trane (Vidalia, GA) 2013-09-16 Tank Station for Coil and Fan Door Production Item B ITEM NO. DESCRIPTION

More information

SULLAIR DESICCANT DRYERS

SULLAIR DESICCANT DRYERS SULLAIR DESICCANT DRYERS Sullair An industry leader Leadership Since 1965, Sullair has been recognized worldwide as an innovator and leader in rotary screw compression and vacuum technology. Sullair designs

More information