Floor sensor (NTC) Temp (C o ) Value (kohm) 10 o C 19,9 kohm 15 o C 15,7 kohm 20 o C 12,5 kohm 25 o C 10,0 kohm 30 o C 8,0 kohm

Similar documents
EB-Therm 300 E / SSTL MONTERINGSANVISNING / INSTALLATION INSTRUCTIONS LEGGEANVISNING / ASSENNUSOHJEET

Instruction FH-CWP Thermostat

INSTALLATION INSTRUCTIONS

danfoss Heating Solutions 5

WS WEATHER STATION

Operating Instructions

installation guide digital timer thermostat

RET2000 MD Electronic digital thermostat with LCD, delayed start. Danfoss Heating. Installation Guide

EUROSTER 2510 USER MANUAL 1 EUROSTER 2510

Easy-Stat. Wireless Programmable Room Thermostat Pt No

Operating your heating system with the Prefect PRE5701 Programable Thermostat

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

SOLO User Guide. Description. Installation. Programmable Dual Voltage Thermostat 240 V (120 V)

Original instructions. Thermoplus PL RU

Owner s Manual. Part Number 33CSSP2-FC BACK LIT LIQUID CRYSTAL DISPLAY MODE BUTTON

FanJu FJ3373 NO RCC Weather Station

QuickStat-TC Installation & Operation Manual

WEATHER STATION (RC-DCF) USER MANUAL

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

Digital Thermostat Models: VS30W and VS30B

Owner s Manual. Part Number 33CS250-FS and 33CS220-FS

TH232-AF-230 Installation Instructions

TP-PHP01-A,TP-PAC01-A &TP- PRH01- B Performance Series Programmable Thermostat. Owner s Manual

VERSO-P, VERSO-R Series Air Handling Units with C3 Control System Electrical Installation and Operation Manual

Rotex Underfloor Heating User Guide

MAKING MODERN LIVING POSSIBLE. Danfoss Heating. RET2000 B/M/MS Electronic digital thermostat with LCD Installation Guide

Installation and Programming Instructions for. Deluxe Programmable Thermostats

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

ELECTRONIC THERMOSTAT

User s guide. Multiple programming Electronic thermostat

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

For the owner and the heating engineer. Operating and Installation Manual VRC 400. Programmable weather compensator with separat HW time control

Installation Guide. DEVIreg 535. Electronic Thermostat.

Operating instructions. For the operator. Operating instructions VRT 350. Room temperature-controlled controller GB, IE

EUROSTER 2510TX USER MANUAL EUROSTER 2510TX

stock code 5265 FIXING GUIDE Thermonet underfloor heating programmable thermostat kit

DEVIreg Opti Electronic Timer Thermostat fulfilling Eco Design Directive

Type UDG, UCG, UTN, USG

Operation manual. Daikin Altherma Low temperature split EHBH04CBV EHBH08CBV EHBH11CBV EHBH16CBV

SAT-3 Room Temperature Controller

User Guide. Color Touchscreen Programmable Residential Thermostat. ComfortSense Model: 13H /2015 Supersedes 7/2015

Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3

Instruction manual. Aluminium radiator with ceramic heart. Smart Electric Heaters

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

CEM-24 Series. Owner's Manual - Installation and Operating Instructions

USER MANUAL Comfort System4 TM

Operating instructions Clock thermostat

OWNER S MANUAL. Part Number P RF

THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE.

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

C-Stat 17-ZW User Instructions

Operation manual. Daikin Altherma Low temperature split EHBH04CB EHBH08CB EHBH11CB EHBH16CB EHBX04CB EHBX08CB EHBX11CB EHBX16CB

TH146-P-2H1C. 1. Introduction. 2. Installation. 1.1 Applications. 2.1 Control Module (CT280-2H1C) 1.2 Supplied Parts. 1.

Please read this manual carefully before installation and use.

CS027 User Instructions

Installation & User s Instructions

AUS. Devireg TM 535 Installation and user manual

MAKING MODERN LIVING POSSIBLE. User Guide. ECtemp 550. Electronic Intelligent Thermostat.

Veria Control T45. Installation guide. Installationsanleitung. Installasjonsveiledning. Installationsguide. Asennusopas. Installationsvejledning

SAS908WHB-3-RF/B WIRELESS THERMOSTAT

SAS803WHL-7 Thermostat for floor heating

COMF RT SYSTEM. T-32-TS Touchscreen Thermostat. User Manual

Drayton Digistat +3RF

Energy Plannersm Programmable Thermostat Customer Guide. Take control of your comfort and energy savings

Control solutions Biofloor

Wireless thermostat SI-3 Installation and user guide

Clima Infrared Radiant & Convection Panel

Digital Thermostat. Models: VS35W and VS35B INSTALLER / USER MANUAL

Owner s Manual. Part Number 33CS250-RC

HEAT HEAT HEAT COOL COOL PUMP OWNER S MANUAL 7-DAY TOTALINE

Elektros montavimo ir eksploatavimo instrukcija 2 Electrical installation and Operation Manual 18 Инструкция по электромонтажу и эксплуатации 34

ETN-24-SUPER-PROG (US Program - Celsius)

LONG-RANGE WIRELESS WEATHER STATION WITH IN-OUT THERMO-HYGROMETER AND RF CLOCK

Operating instructions

ET4 heat/cool day RF programmable room thermostat. ET4 Receiver

For the owner and the heating engineer. Operating and Installation Manual. timeswitch 140. Two-channel 5/2 or 7-day full programmer

ComfortSense 7500 Thermostat. User Guide

MAKING MODERN LIVING POSSIBLE. Installation Guide. ECtemp 550. Electronic Intelligent Thermostat.

OWNER S MANUAL Venstar Inc. 08/07

1F97-51 OPERATION GUIDE WHITE-RODGERS. Operator: Save this booklet for future use! 7-Day Programmable Electronic Digital Thermostat

Model: Slimline-RF. 1 Slimline Series

Programmable Towel Radiator Manual

User s Manual

FUNCTION AND CONTROLS

Instruction manual for models:

Installation Guide. DEVIreg 534. Electronic Thermostat.

Owner s Manual ENERGY EFFICIENT, AT A TOUCH OF A BUTTON TSTPRH01, CÔRR 7 TSTWRH01 CÔRR 7C RESIDENTIAL THERMOSTATS. Côrr 7 Series

1. COMMISSIONING OF THE BOILER en DESCRIPTION FUNCTION BUTTON DESCRIPTION SYMBOL DISPLAY

5230IG. Thermotouch 3.2aP Wireless Heating Thermostat

Underfloor Heating. undertile heating

Evolution Control. Zone Control Homeowner s Guide

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

Designer TT Programme Set Up

CONTENTS. Backup Batteries

DIGISTAT PROGRAMMABLE 24 HOUR ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat.

HEAT COOL. Meets Commercial California Title 24

Model: C87207 / C87061 Instruction Manual DC: DUAL ALARM CLOCK

Table of Contents. SLIMLINE Series MODEL: SLIMLINE

OPERATING MANUAL. Need Help? This manual covers the following models: T805. Table of Contents

ERV-24. Technician Settings & Operating Manual. Protected by one or more of the following patents: US 5,547,017; 5,881,806; 6,431,268; CA 2,245,135

Transcription:

FENIX THERM 350

a) b) Fig 1 c) L N Load Load SG - Not in use Sensor Sensor Fig 2 Fig 3 Fig 4 1 9 8 [ 6 [ 7 5 Fig 5 2 4 3 Floor sensor (NTC) Temp (C o ) Value (kohm) 10 o C 19,9 kohm 15 o C 15,7 kohm 20 o C 12,5 kohm 25 o C 10,0 kohm 30 o C 8,0 kohm

Termostat musí být trvale napájen. Zapojení pro instalace s blokováním ve vysokém tarifu signálem HDO (např. sazba D45d)

Installation instructions FENIX Therm 350 English Page 1/3, 071217 Abbreviations in the installation instructions LEd L LEd H Contrast Lock Settings Low light intensity in control lamp High light intensity in control lamp Time Date On Off R F R&F Display 12 hours display 24 hours display Room Floor Room and floor Setting function Programming Programme for home environment OH AF Programme for office environment User settings Frost protection programme 4 events Activating time in % Daylight Saving Time (DST) Overheat protection Adaptive function MD Monday TU Tuesday WE Wednesday TH Thursday FR Friday SA Saturday SU Sunday Description FENIX Therm 350 is a microprocessor-controlled thermostat with LCDdisplay. The front is fitted with an LED with dual function (Fig 1a) and three control buttons (Fig 1b). Fuzzy-technology Temperature control is done with help of an algorithm, which uses fuzzy technology. The technology involves the thermostat testing and collecting data from start-up, and based on this compute when to switch on and off. This technology reduces the temperature variations and thus provides a more constant temperature and lower energy consumption. The floor temperature varies less than +/- 0.3 degrees. See figure below. TEMP TIME Installation Flushing mounting - FENIX Therm 350 is fitted in a standard appliance box 65 mm. The thermostat shall be placed in a location protected from sunlight and draught. The floor sensor must be fitted in a flexible conduit laid in the floor, where the conduit endings are sealed so that the floor sensor can be easily replaced. All tubes leading into the appliance box must be sealed so that the air temperature sensor cannot be affected by draught. 1. Make sure the box is level with the wall. 2. Press the latch, at the right, (Fig 1c) and take off the front and frame. 3. Connect power, voltage 230 VAC, load and floor sensor cable. Any extension of the floor sensor cable must be by means of high voltage current. Protective conductor for incoming feed and heating cable is connected with a connection clip in the box (Fig 2). 4. Insert the thermostat into the mounting box and screw tight with supplied screws. 5. Fit the frame and front. 6. If the thermostat will be installed in double frame, innercorner must be removed. Fitting with extension frame Attach the extension frame E 85 816 68 (Fig 3) to the wall with screws. Then fit the thermostat according to the instructions above. Fitting with Backplate If the supplied frame does not cover the hole, Backplate is used (Fig 4). Settings Thermostat with fuzzy-technology Thermostat without fuzzy-technology Display description The thermostat s LCD-display has a blue background light, which is activated when a button is pressed and shines for 30 seconds after the last push of a button. The LCD-display (Fig 5) shows the following items: 1 Day of the week 2 Time & date 3 Temperature 4 Menu 5 Functions 6 Preset programmes 7 Own settings 8 Programme is running 9 Lock MD TU WE TH FR SA SU Shows current day of the week (Mo-Su) Shows time in 12- or 24 hours format. Date is shown as MM:DD and years are shown as 20YY. Shows set point in C. R&F Shows actual temperature /selected menu. Shows the thermostat s selected function. Shows whether any programme is running (office, home environment, own settings, frost protection). Shows whether any event functions are selected (wakeup, out, back or night). Shows that a programme is running. Shows that the thermostat is locked. The first time the thermostat is switched on it is set to normal mode. The display shows: 1. Day of the week 2. Time 3. Set point (set temperature) 22 C 4. Thermostat setting (F if floor sensor exists, otherwise R) 5. Adaptive function on Menu The menu is accessed by pressing when the thermostat is set to normal. Then press or to move around the submenues and to select a setting. To exit a menu without selecting a submenu, either press or until the display shows END. Then press or wait 30 seconds and it will return by itself. Power on/off This function puts the thermostat into hibernate mode, as long as it is in this mode it is not controlling the heating. The clock functions as normal and the times and temperatures that have been programmed remain in the memory. To access standby mode, press and hold for 4 seconds. By pressing and holding for 4 seconds, you return to normal settings. Lock indicates that the thermostat is locked. To lock the thermostat: 2. Press repeatedly untils the display shows. Confirm with. 3. Unlock the thermostat by pressing and simultaneously. Hold them down until disappeares. LED The thermostat is fitted with an LED with dual function (Fig 1a). 1. Green light the thermostat is on and the underfloor heating is switched off. 2. Red light the thermostat is on and the underfloor heating is activated. 3. Flashing green and red light error indication. The thermostat shows error messages until it is switched off. Continue reading under troubleshooting. 4. No light the thermostat is switched off or is not getting any current.

Installation instructions FENIX Therm 350 English Page 2/3, 071217 The LED s light intensity has two settings, low and high. The standard setting is low. To set the desired level. 3. Press repeatedly until the menu shows LEd. Press. 4. Press or to select setting. the menu shows LEd L or LEd H. Confirm with. Time, date and temperature The thermostat shows time and date. The calendar switches over automatically in leap years and automatically adapts to DST. To be able to use the programme for temperature reduction, time and date must be set. The thermostat automatically computes which day of the week it is. Set time 3. The menu in the display shows. Press. Hours now flash. 4. Press or repeatedly to set the hours. Confirm with. 5. Repeat the previous step to set the minutes. 6. Repeat the previous step to set month and year. Set date 4. Press or repeatedly to set the date. Confirm with. Deactivate DST 4. The display shows the current setting. Press to change. Confirm with. Temperature For every push on or the desired temperature increases or decreases by 0.5 º C. How the thermostat shows the time is set as follows 4. The display shows the current setting. Press to change. Confirm with. Thermostat settings FENIX Therm 350 can work with three separate functions: R&F - Room - and floor-thermostat A built-in sensor regulates the room temperature. The external floor sensor functions as a floor temperature limiter. The limitation can be set between 5 C and 45 C. The factory setting is 35 C, which gives a surface temperature of approx. 27 C. To adjust overheat protection temperature: 2. Press repeatedly until the display shows. Press. 3. Press repeatedly until the display shows OH. Press. 4. Actual temperature is now flashing. Press or to change. Confirm with. In rooms with large windows which are exposed for sunlight, we recommend this setting. F - Floor thermostat - The external floor sensor regulates the floor temperature. Preset value is 22 C. If the floor sensor is engaged the first time the thermostat is switched on, the thermostat selects this function automatically. To select any of these settings: 4. One of the icons R, F or R&F flash, depending on which is the current setting. 5. Press or to change selected setting. Confirm with. NOTE! R can not be selected if the floor sensor is connected. Preset programme The thermostat has two preset programmes for temperature reduction which are adapted for home- or office environments. Programme for home environment. The temperature is automatically reduced by 5 º C during Mo Fr 08:30 15:00 Mo Su 23:00 05:00 Programme for office environment. The temperatur is automatically reduced 5 º C the whole time except for: Mo Fr 06:00 18:00 To select any of these programmes: One of the icons for preset programmes will flash, depending on the current setting. (If no icon flashes, no preset programme is selected). 3. Press or to select between,,, or no programme. Confirm with. If a preset programme is selected the programme starts up. is shown together with actual icon and indicates that a programme is running. User settings FENIX Therm 350 has programmes for own settings. You can set four events Monday to Sunday. The four events Mo-Su are WAKEUP OUT, BACK and NIGHT. 2. Press repeatedly until the display shows 3. Press repeatedly until the display shows. Press.. Press. 4. The MASTER set, MD TU WE TH FR SA SU, all 7 days are now displayed. Press. 5., actual time and temperature is shown in the display. 6. The hours digits are flashing. Press or to set the hours. Confirm with. 7. Press or to set the minutes. Confirm with. 8. Press or to set the temperature. Confirm with. 9. is shown, repeat steps 6-8 to set the time and temperature for this event. 10. is shown, repeat steps 6-8 to set the time and temperature for this event. 11. is shown, repeat steps 6-8 to set the time and temperature for this event. If any of the days of the week are divergent, do as follows: 3. Press repeatedly until the display shows. Press. 4. Now actual MASTER set is shown, MD TU WE TH FR SA SU. Press or repeatedly until the divergent day is shown. Confirm with. 5. Program the 4 events of the day, according to step 6-11 above. Is there any more divergent days, repeat steps above. Display of actual value (current temperature) When the key set is locked, press. The light comes on and the current temperature is displayed for 30 seconds as small digits above the set value (the temperature required). R - Room thermostat - A built-in sensor regulates the room temperature. The function cannot be selected when the floor sensor is connected. If the floor sensor is not connected at the first switch-on, the thermostat automatically selects this function.

Installation instructions FENIX Therm 350 English Page 3/3, 071217 If the thermostat is set as a floor thermostat (F), it displays the current temperature in the floor. If the thermostat is set as a room thermostat (R), it displays the current temperature in the room. If the thermostat is set as a room and floor thermostat, (R&F) it displays the current temperature in the room. Frost protection programme This programme is designed for long absence. When this program is selected, the thermostat will regulate by this set value. All other set values and settings will remain in memory and the thermostat will go back to them when this program will be deactivated. The temperature can be between 5 C and 15 C. Factory set temperature is 10 C. 3. Press repeatedly until the display shows. Press. 4. Now the selected temperature is flashing. 5. Press or to select the set value. Confirm with. To activate this programme: One of the icons for preset programmes will flash, depending on the current setting. (If no icon flashes, no preset programme is selected). 3. Press to select. Confirm with. If a preset programme is selected the programme starts up. is shown together with and indicates that the programme is running. Technical specifications Voltage 230 VAC-50 Hz Air temperature range 5-37 º C Floor temperature range 5-37 º C Temperatur limiter 5-45 º C Breaking capacity 3600W / 16A / 230 VAC Connection cable max 2,5 mm 2 Load cos φ = 0,3 Hysteresis +- 0,3 º C Protection class IP21 Run reserve 36 hours Colour Polar white as standard, aluminium and bronze as option Background lighting Shines 30 seconds after the last button is pushed Max length sensor cable 45 m, 2 x 1,5mm 2 The LED s indication: Green Red Flashing green and red light 230 VAC supply connected Floor heating cable operating Error indication Adapted for Eljo Trend, Elko RS, Strömfors and Merten frame-systems. EMC-certified and can handle an overvoltage of 2 500 VAC. Safety standard: CE Fulfils the RoHS and WEEE-directive Display contrast 2. Press. The display shows 1,2, 3...8 depending on actual setting. 3. Press or, to change the contrast. Confirm with. Adaptive function The thermostat is equipped with a so-called adaptive function, which means that if you have programmed the thermostat to keep a certain temperature at a certain time, the thermostat will calculate itself when to start heating so that the floor surface will keep the set temperature at the preset time. Factory set is ON. To deactivate the adaptive function: 1. Press.The display shows. 2. Press repeatedly until the display shows. Press. 3. Press repeatedly until the display shows AF. Press. 4. The display shows the actual settings. Press to change. Confirm with. FENIX Therm 350 with accessories Article FENIX Therm 350 Extension frame Sensor cable 3 m (included in the pack) Back plate, polar white Model no. 66 210 84 Type IB Degree of pollution 2 Rated impulse voltage = 4000V Size of terminal 2,5 mm 2 Dimensions (mm) 81x81x40 81x81x18 86x86x6 Operation time The thermostat can show the operation time in percent for the last 24 hours, 7 days, 30 days or 365 days. To see the percentage operation time: The display shows operation time in percent for the last 24 hours. 3. Press. The display shows and operation time in percent for the last 7 days. 4. Repeat the steps above to show the operation time for the last 30 days or 365 days, respectively. Ventilation mode If the measured temperature is reduced by more than 3 C during one minute, the thermostat is automatically put in ventilation mode. The thermostat stops heating for 15 minutes. When 15 minutes have passed, the thermostat returns to normal mode. The ventilation mode is always active, regardless of which programme is running. Troubleshooting When an error occurs, the thermostat will switch off the heating. The LED flashes alternately in red and green. The LCD-display shows a flashing error code, the display shows according to below: Error 1: Short circuit room sensor. Error 2: Interruption room sensor. Error 3: Short circuit floor sensor. Error 4: Interruption floor sensor. Start / Stop set back programme This will not erase settings, will only start and stop set back programme. Start programme: 1. Press. Display shows. 2. Press repeatedly until display shows. Press. If a programme is active one icon is flashing,,,. 3. Press or repeatedly to choose icon, chosen icon must flash. Confirm with. Stop programme: 1. Press. Display shows. 2. Press repeatedly until display shows. Press. If a programme is active one icon is flashing,,,. 3. Press or repeatedly until no icon flash. Confirm with. The supply cord of this control can be replaced only by the manufacturer or his accredited service agent.