BALAJI FIRE PROTECTION SYSTEMS:

Similar documents
Hiren Industrial Corporation


FIRE SUPPRESSION SYSTEM

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009

TRIMAX ASIA ENGINEERING & CONSTRUCTION (PG U )

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle. TM TM


Fire protection for buildings

CHAPTER 8 OCCUPATIONAL HEALTH AND SAFETY

Fire. IMO fire control signs - according to IMO Resolution A.654 (16) (mm) 150x x200

Enclosure 4- RISK ASSESSMENT

DRY POWDER FIRE EXTINGUISHER (Stored Pressure) ABC TYPE - PORTABLE

International Safety Guide Chapter 30 for Inland Navigation Tank-barges and Terminals. Chapter 30 FIRE-FIGHTING

Exploration and extraction can be on land or on offshore platforms. Once extracted, ground transportation is done by means of oil or gas pipelines,

IMO INTERPRETATIONS OF FIRE PROTECTION-RELATED PROVISIONS OF THE HSC CODE

School of Fire & Safety, GSFC University

Design and Supply of Fire Equipments. External Fire Fighting Systems.

CO2 COCO GAS FLOODING SYSTEM

An Overview of Extinguishing Systems for Computer Equipment

Fire Suppression. Water-Mist : A Revolutionary Green Technology in. - by Nimit Sheth TALL, SMART, SAFE BUILDINGS FOR SMART CITIES.

Our Mission. About Us. To create awareness of the essentiality attached to a firefighting system, as an important requisite in everyday life and loss

Government of Bermuda Bermuda Shipping and Maritime Authority BERMUDA SHIPPING NOTICE

STORED PRESSURE YES TEST STANDARDS: CAN/ULC S504 & ANSI/UL 229 CAN/ULC S508 & ANSI/UL 711. Available Options: Stationary Design Tow Loop

PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems

WATER MIST CONVENTION AND EXHIBITION

ENGINEERING STANDARDA FOR FIRE FIGHTING HOSE BOX AND SHELTER FIRST EDITION APRIL 2015

Technical write-up on Fire safety services

Institute for Plasma Research Welcomes you all on

Reliance Fire Protection Systems

& Fire Extinguisher Training

MAINTENANCE AND INPSECTION OF FIRE PROTECTION SYSTEMS AND APPLIANCES

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle.

Checklist For Life Safety

The Next Generation of Foam Fire Suppression. Automatic CAF Fire hose reel system FEATURES

The Combustion Process THE FIRE TETRAHEDRON FUEL TEMPERATURE

In the year 1988, Amit Industrial Corporation is a reputed name in the industry for Manufacturing and

Element C3.4 Fire Fighting Equipment

CO 2 EXTINGUISHING SYSTEMS

ODS & SGG Alternatives for the Fire Protection Industry 2018

Chapter 12 HOT WORK OPERATIONS. Purpose:

White Paper. The Victaulic Vortex Fire Suppression System Fire Suppression for Electrical and Electronic Applications

Application of BS 8489 to the Protection of Generator Enclosures. IWMA, BRE 22 nd March 2017 Dr Tim Nichols CPhys FIFireE

RULES 1978 UNDERGROUND COAL MINES FIRE PRECAUTIONS

SAFETY THE BEST FOR YOUR EQUIPMENT

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS PART 8. PORTABLE FIRE EXTINGUISHERS

WAS STARTED BY CARLOS BAHAMONDES MASAFIERRO

Gulf Industrial Systems Co. Fire, Safety & Security Systems

GAS EXTINGUISHING SYSTEMS INERT GAS. Argon Extinguishing Systems. Fire Protection Systems

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

Owner/Operator Guide for Successful Sprinkler and Fire Pump Systems

3. Low location lighting system. 4. Illuminated emergency units. 5. Cabin escape route plans

Foam Systems U.S. Quick Reference Guide

COGEN CONSULT. Page 1 of 23

RULES FOR STATUTORY SURVEY OF SEA-GOING SHIPS. FIRE-FIGHTING EQUIPMENT AND ESCAPE EQUIPMENT 2017 January

Self Expanding Foam Fire Suppression System SPECIFICATION SHEET Rev

FIREFIGHTER II: FIRE DEPARTMENT COMMUNICATIONS COMMUNICATIONS: SKILL SHEET #2 Define and Demonstrate Fire Department Radio Procedure

Fire suppression systems for server rooms and data centres

Fixed Fire Extinguishing Equipment and Systems

Following are the systems proposed as per NBC & Local Fire Authority:

Transforming Challenges with Expertise. Total Protection. from concept to commissioning

What is HI-FOG? The natural enemy of fire

HI-FOG for buildings. Technical introduction. Protecting people, property and business continuity. Jussi Tiainen

TECHNICAL AND USER REQUIREMENTS FOR PERSONAL ALERT SAFETY SYSTEMS

STEPP SRM 10x120(Asphalt Recycler) SPECIFICATIONS. SRM 10x120 Self Loading

FIRE AND FIRE FITTING By Mr. Prashant Sansare

DARB AL SALAMAH SAFETY SYSTEMS YOU ARE SAFE IN OUR HANDS

Carbon Dioxide Fire Suppression Systems

PROFILE. industrial services rental trading

MASTER COURSE OUTLINE

FIRE EXTINGUISHERS. Chapter 2. - Co2 Fire Extinguisher - Dry Foam Fire Extinguisher - Foam Fire Extinguisher - Portable Foam Applicator

Radiator Additive. ZetaLube. Description

Product Supply, Hire & Service. Complete Safety Solutions for the Oil, Gas, Marine & Energy Industries. Safer.Smarter.Tyco.

contents iii Drilling Tools 27 Adjustable Choke 27 Automatic Drillers 29 MWD and LWD Tools 30 How They Work 30 Uses 30

Winnipeg Fire Department Fire Prevention Branch

TECHNICAL AND USER REQUIREMENTS FOR FIRE-FIGHTING PRESSURE HOSES FOR FIRE-FIGHTING PUMPS

Vaults 5/03/2015. Introduction. Vault Types. Stand alone building Free standing structure VAULTS

BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 6

Foam Products ENGLISH

Firefighting Monitors Tunnels Fire Protection Systems. Integrated Fire Safety and Security Solutions

Unit 5: Fire Safety Installations

Explosion Protection Engineering Principles

DMP & RISK MANAGEMENT PLAN

Creating a safer world!

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS

HIGH PERFORMANCE & QUALITY INFRASTRUCTURE PROJECTS

FOAM CHAMBER MODEL - FCA & FCA-S TECHNICAL DATA FEATURES APPLICATION. Carbon Steel Construction FCA-65, FCA-80 & FCA-100. Stainless Steel Construction

(Material correct at 1/11/2011)

PRODUCT LISTING DATA SHEET (Active Fire Protection Equipment)

(2) Various fire sections enclosed by various classes of fire divisions; (3) Arrangement of fire detectors and manual fire alarm stations;

BOC FS125 The Fire Extinguishing Solution

MSC Guidelines for Foam Fire Suppression Systems

'Safety, Signs and Signals' Results For JOE BLOGGS. Safety, Signs and Signals. Summary

FAS INTERNATIONAL COMPANY PROFILE. Thank you very much for giving us opportunity to introduce ourselves.

DIVISION 21 FIRE SUPPRESSION

Performance Based Fire Protection With Water Mist

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

Notice on the implementation of the amendments to the FSS Code in resolution MSC.339(91)

PHIREX AUSTRALIA. FOGEX & MISTEX WATER MIST FIRE PROTECTION

-SAMPLE- Safety Inspection Checklist: Manufacturing

Highly Protected Risks in Power Generation Stewart Kidd outlines the issues to consider when installing active fire suppression in power stations THE

Transcription:

BALAJI FIRE PROTECTION SYSTEMS: Automatic Water Sprinkler System: One of the oldest & traditional ways of fire protection, which is water based protection system, is in the form of automatic sprinklers. BFS India can provide you with complete designing of sprinkler system for any kind of hazard. Our design facility also has the provision for calculation of water demand using latest licensed hydraulic calculation software s which will accurately determine the water demand as per the standards. Various sprinkler system network designing can be done to cater the specific needs of the customers varying from residential to commercial and industrial. Manual Fire Hydrant Systems: Depending on the type of hazard, different varieties and sizes of fire extinguishers are located per standards which form typical manual fire protection systems. Also semi automatic water based systems are classified as manual fire protection systems. In this case the water under pressure will be available in the pipe line. The valves (normally with 1.5 outlets within the building) have to be opened & hoses pulled down to fight the fire. The landing valves & fire hose cabinets are provided for the use of occupants to fight small fires. Hydrants (normally with 2.5 outlets located outside the building) & fire hose houses are provided for the usage of trained fire fighters. These are the most common but effective systems which we design on daily basis per standards & using hydraulic calculations. Ph:09619235585, 09324245687 Email: info@balajifire.com, balajifire101@gmail.com, Website: www.balajifire.com Page 1

Fire Pumps & Water Tanks: For all water based & foam based, automatic or semi automatic fire protection systems the water will be available under pressure at all times. This is achieved by providing fire pump set and water tank, all inter connected. Generally there will be an electric motor driven main fire pump, the size (flow & pressure) of which is based on the highest demand from hydraulic calculations. There will be a stand by Diesel engine driven fire pump of same capacity for emergency purpose. Additionally there will be a pressure maintaining device also called as a Jockey pump whose pressure rating will be equal to that of the main pump but with a very low flow rate. Other mandatory accessories will all be fitted together & the inlet connected to a dedicated fire water tank. The capacity of the tank depends on the hazard nature which defines the time period required multiplied with the flow of the main fire water pump. All of these again needs experienced engineers to design an optimum package meeting the standards, yet economically viable. The team at BFS India has this in abundance with right tools to execute in a very quick time. FIRE ALARM SYSTEMS Today the fire alarm system has evolved a long way. Hence the designing of Advanced Intelligent Fire Alarm Systems as per International standards is a challenge which BFS India can easily accept & successfully accomplish. The designing of Fir e Alarm System is not only limited to providing a conceptual design, but we also provide actual design drawings which includes Shop Drawings, Installation drawings, Wiring Diagram, Input/Output Configuration which will help the installer to install the system accurately. Our design will be customized as per the various manufactures of the systems. Digital Voice Evacuation is an extension of fire alarm system which is integrated with fire alarm system to provide occupants with digitally pre recorded messages to help them evacuate in case of emergency. In a huge facility one system may not be sufficient, hence it is required to use many fire alarm systems, all of which can be networked as an integrated system with inf ormation available at single window. Our design team of BFS India has designed & successf ully delivered many such complex proj ects. BFS India of f ers designs for Network Integrated Systems using traditional wired technology, Optic fiber technology, IP based Networking using CAT 5 W ire or Wireless technology. Ph:09619235585, 09324245687 Email: info@balajifire.com, balajifire101@gmail.com, Website: www.balajifire.com Page 2

Deluge Systems: As the name indicates, flooding the entire hazard area with huge quantity of water (could be foam too) is known as deluge systems. These systems are sometimes used for extinguishment, sometimes for control of fast spreading fires & sometimes as surface cooling. Applications are wide & mechanism of operation are also multiple like wet pilot actuation, dry pilot actuation, electrical actuation, manual actuation & these sometime combine with single pre action & double pre action thus making it again the need of skilled & experienced Engineers to understand, engineer & design the specifically required system for water or foam again by running multiple hydraulic calculations. BFS India again is proud to have a team of people who have designed, installed & successfully commissioned hundreds of such systems. GAS FLOODING SYSTEM: These systems also known as clean agent systems are widely used where the environment needs no tedious cleaning after the extinguishment of fire like computer rooms, control rooms, record rooms, libraries, electrical hazards such as switchgear rooms, substations, battery rooms etc. Carbon dioxide systems are generally used for unmanned areas since it could be lethal for human beings though it is economical & one of the best agent for extinguishing the fire. Low pressure CO 2 systems (360 psi) are used where the quantity of the gas required is high as it is available with tanks from 1 tonne to 10 tonnes & comes with its own refrigeration unit to store CO 2 in its liquid form. High pressure CO 2 systems (850 psi) are used where the quantity of gas required is small as they are available in standard bottles of 50, 75 & 100 lbs capacity wherein the gas is stored under high pressure at normal ambient temperature. Inergen systems are the evolution of new clean agent systems after the ban on Halon systems. It kills the fire by inerting the hazard with huge quantity of inert gas like Nitrogen. The initial fill & refill of gas is very economical though the storage cylinders & their maintenance might be an expensive affair. Ph:09619235585, 09324245687 Email: info@balajifire.com, balajifire101@gmail.com, Website: www.balajifire.com Page 3

FM200 (trade name) is one of the most successful replacement of Halon systems where it is human friendly & not having the ozone depletion potential. It is stored under pressure of Nitrogen at about 360 psi. Sapphire/Novec is one of the new replacements for Halon systems which is again human friendly, zero ozone potential & no global warming. Easier to handle as it is in its liquid form at normal ambient temperature & flows easily as compared to FM200. Designing of above mentioned gaseous fire protection systems needs highly skilled, competent & preferably factory trained personnel as they involve high tech equipment with high pressures & involves flow calculations on special software which are generally provided by the manufacturers. At BFS India we have the team with above qualification & who have the experience of designing, erecting & successfully commissioning, hundreds of such systems. We have the necessary software too for running the calculations. FOAM PROTECTION SYSTEM: One and the only economical & viable fire extinguishing mechanism with liquid fuel fires is the Foam fire protection system. With the growing demand of these fuels in the modern age the storage, handling & transportation of these fuels need to be protected thoroughly as they are highly flammable. Elimination of Oxygen from the fuel surface by an effective blanket formation of foam is the mechanism of killing a fire in this system. However getting the right mixture(concentrate, water & air), quantity & quality of this foam again needs thorough understanding, engineering and selection of the correct, tested & approved combination of equipment & foam concentrate(available in different types and different percentage concentrates, etc,) lies in the hands of experienced engineers. Multiple hydraulic calculations & many a times reverse calculations will have to be performed to ensure the foam quantity remain for the desired period of operation. Yet again at BFS India, we have such experience with many such systems designed, erected & tested successfully. We do have the software for running such complicated hydraulic calculations. Ph:09619235585, 09324245687 Email: info@balajifire.com, balajifire101@gmail.com, Website: www.balajifire.com Page 4

Other Fire & Safety Euipments: FIRE EXTINGUISHERS FIRE FIGHTING CHEMICALS FIRE PROTECTION SYSTEMS FIRE HYDRANT ACCESSORIES OTHER FIRE FIGHTING ACCESSORIES COUPLINGS AND ADAPTERS NOZZLES AND BRANCH PIPES AUTOMATIC FIRE SPRINKLER SYSTEM Ph:09619235585, 09324245687 Email: info@balajifire.com, balajifire101@gmail.com, Website: www.balajifire.com Page 5

WATER/FOAM MONITORS FOAM MAKING EQUIPMENT S FIRE ALARM AND SMOKE DETECTION SYSTEM FIRE PUMPS FIRE DOORS FIRE SUPPRESSION SYSTEM SAFETY PRODUCTS Ph:09619235585, 09324245687 Email: info@balajifire.com, balajifire101@gmail.com, Website: www.balajifire.com Page 6

SAFETY AND PHOTOLUMINESCENT SIGNAGES FIRE FIGHTING EQUIPMENT'S: ALL TYPES OF PORTABLE/TROLLEY MOUNTED FIRE EXTINGUISHERS LIKE WATER CO2, DCP, ABC, CO2, MECHANICAL FOAM & CLEAN AGENT. NEW CO2/ N2 GAS CARTRIDGES AND REFILLS. WATER MONITORS WITH DIFFERENT TYPES OF NOZZLES (STAND POST/TROLLEY MOUNTED) FOAM WATER MONITORS WITH DIFFERENT TYPES OF NOZZLES (STAND POST/TROLLEY /TRAILER MOUNTED) JUMBO JET NOZZLES AQUA FOAM EQUIVALENT NOZZLES FOR WATER/FOAM/DCP/ABC MONITORS. MEDIUM EXPANTION FOAM GENERATORS HIGH VOLUME FOAM POURERS. FOAM MAKERS WITH VAPOUR SEAL CHAMBER MOBILE FOAM UNITS SMOKE EXHAUSTER'S-ELECTRICALLY/WATER TURBINE OPERATED SMOKE GENERATORS-ELECTRICALLY OPERATED (NON TOXIC) WATER CURTAIN & WATER FAN NOZZLES (WATER BEATER) MFG- 5 & MFG- 10 FB-2X, FB-5X, FB-10X, INLINE INDUCTOR'S WITH AND WITHOUT VARIABLE FLOW Ph:09619235585, 09324245687 Email: info@balajifire.com, balajifire101@gmail.com, Website: www.balajifire.com Page 7

CONTROL VALVES. PORTABLE GROUND WATER MONITORS. HALON/ABC MODULAR TYPE FIRE EXTINGUISHERS IN M.S./S.S. WATER NOZZLES & BRANCHES LIKE FOG, REFINERY, TRIPLE PURPOSE, NAVY, REVOLVING, MULTIPURPOSE, DIFFUSER, OIL FIRE, FLAT SPRAY, LONDON HAND CONTROLLED ELKHART TYPE, KUGELITE TYPE FIREMAN S FAVORITE THE WORKHORSE PISTOL GRIP, NO-BACK-PRESSURE NOZZLE. GUNMETAL COUPLINGS, ADAPTERS, DOUBLE MALE/ FEMALE ETC. SUCTION FITTING, NRV, STRAINERS ETC. RUBBER/ PVC SUCTION HOSES WITH END COUPLINGS WATER EJECTOR PUMPS DRY RISER & AIR VENT VALVES. COLLECTING/ DIVIDING BESEECHING, CONTROLLED BREACHING APPLICATORS FOR DCP, CO2 (TWIN TROLLEY) AND METAL FIRE EXTINGUISHERS. FIREMAN S AXE (CERTIFIED UP-TO 20,000 VOLTS) AND FIREMAN S HOOK WITH POLE, RESCUE TOOLS HYDRAULIC TESTING MACHINE WITH ADAPTERS FOR EXTINGUISHER TESTING HOSES, HOSE BOXES, HOSE REELS, HOSE NOZZLES, HOSE BINDING MACHINES, HOSE WASHING MACHINES ETC. CO2/ HALON/ FM 200 SYSTEM MANIFOLDS, SPRAYERS, NOZZLES, SPRINKLERS FIBERGLASS (FRP) BOXES FOR FIRE HOSE/FIRE EXTINGUISHER/ BREATHING APPARATUS SPARK ARRESTOR'S FOR ALL TYPES OF VEHICLES CORROSION PROOF STAINLESS STEEL FIRE EXTINGUISHERS. UL LISTED MEDIUM VELOCITY SPRAY NOZZLES, DELUGE VALVES & HOSE HOSE RAMPS, FIRE TENDER WHEEL BLOCKS Ph:09619235585, 09324245687 Email: info@balajifire.com, balajifire101@gmail.com, Website: www.balajifire.com Page 8

FLANGE x MALE/ FEMALE INSTANTANEOUS OUTLET CONNECTIONS DESIGNING & INSTALLATION OF SPRINKLER & WATER WALL SYSTEM DESIGN, SUPPLY, INSTALLATION, TESTING, COMMISSIONING OF FIRE FIGHTING AND DETECTION SYSTEMS ON TURNKEY BASIS: FIRE HYDRANT SYSTEM WATER SPRAY SYSTEM AUTOMATIC SPRINKLER SYSTEM WATEAR MIST SYSTEM FIRE ALARM SYSTEM SMOKE DETECTION SYSTEM GAS DETECTION SYSTEM CO2 FLOODING SYSTEM FM 200 FLOODING SYSTEM AND OTHER CUSTOM MADE SYSTEM TO SUIT THE CLIENTS REQUIREMENT OCCUPATIONAL HEALTH & SAFETY PRODUCTS: EXPLOTION PROOF TORCHES. DETECTION METERS AND SENSING ELEMENTS EXPLOTION METERS, COMBUSTIBLE GAS AND OXYGEN INDICATORS ETC. HALF/FULL MASK RESPIRATORS RESPIRATORS WITH CARTRIDGES FOR DIFFERENT GASES/FUMES/VAPOURS FACE MASKS B. A. SETS AND SPARES EYE/ FACE WASH ASSEMBLY & SHOWERS. Ph:09619235585, 09324245687 Email: info@balajifire.com, balajifire101@gmail.com, Website: www.balajifire.com Page 9

GLOVES, BLANKETS, FIRE SUITS, GOGGLES ETC. EARPLUGS, MUFFS AND GUARDS FIRST AID KITS. HELMELTS WITH & WITHOUT SHIELDS SAFETY BELTS, HOOKS, HARNESS, LANYARD, BODY BELTS, CARAQBINEERS, RAIL RIDERS, LIFELINES, ROPES, ROPE GRABS ETC. HAND/ ELECTRICALLY OPERATED SIRENS UNDERTAKES MAINTENANCE CONTRACT FOR FIRE FIGHTING EQUIPMENTS AND SYSTEMS, SPARES: SPARES FOR ALL TYPES OF FIRE FIGHTING EQUIPMENT'S AND SYSTEMS ANNUAL MAINTENANCE CONTRACT FOR FIRE EXTINGUISHERS REFILLING OF ALL TYPES OF FIRE EXTINGUISHERS REFILLING OF CO2 SYSTEM CYLINDERS AND REPAIRING OF VALVES REFILLING OF CO2/ N2 GAS CARTRIDGES RUBBER PARTS LIKE O RINGS, GASKETS, BUSH, WASHERS ETC. HAND GRIP/ NOZZLES/ APPLICATORS OF VARIOUS TYPES FOR HIGHER CAPACITY FIRE EXTINGUISHERS LIKE 25/50/70 Kgs. OF DCP TYPE AND 50/150 Liters of MECHANICAL FOAM ANY IMPORT SUBSTITUTE NOZZLE AS PER CLIENT SPECIFICATION ANNUAL MAINTENANCE CONTRACTS FOR FIRE HYDRANT/ AUTOMATIC SPRINKLER/ WATER MIST/ WATER SPRAY SYSTEM ANNUAL MAINTENANCE CONTRACTS FOR FIRE ALARM AND SMOKE DETECTION SYSTEM ANNUAL MAINTENANCE CONTRACTS FOR CO2/FM 200 FLOODING SYSTEM SPARES FOR FIRE ALARM/ SMOKE DETECTION/CO2 AND FM 200 FLOODING SYSTEM Ph:09619235585, 09324245687 Email: info@balajifire.com, balajifire101@gmail.com, Website: www.balajifire.com Page 10

ALL TYPES OF SPARES FOR HYDRANT/SPRINKLER AND OTHER SYSTEMS Ph:09619235585, 09324245687 Email: info@balajifire.com, balajifire101@gmail.com, Website: www.balajifire.com Page 11