Multilux 4-Eclipse-Set

Similar documents
Thermostatic valves with radiator connection systems

Eclipse F. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

Eclipse. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting

Design-Edition. Design-Edition Thermostatic valves and lockshields, sets

IMI Heimeier Kit Hydroca ble

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

Thermostatic three-way valve body. Thermostatic Radiator Valves without presetting, with automatic bypass control

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

V-exact II. Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting

Vekotrim. Valves for radiators with integrated valve Double connection fitting with shut-off ball valves for radiators with integrated valves

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Mikrotherm. Manual Radiator Valves With presetting

Calypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting

Control valves for floor heating systems. Floor Heating Manifolds

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off

Thermostatic valve bodies

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

thermostatic valve body with stepless precision presetting

Standard. thermostatic valve body without presetting

Multibox. Floor Heating Controller Flush individual room control for floor heating systems

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold

Flush individual room control for floor heating systems

Regulux. Return Lockshield Radiator lockshield with consistent presetting and drain-off facility

Floor Control Set. Floor Heating Controller For constant control of the supply temperature

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge

Thermostatic valve bodies

Three-way reversing valve

Regulux. Radiator lockshield with drain-off facility. To be precise.

Thermostatic head K. with contact or immersion sensor. Thermostat-Köpfe For medium temperature control

Multibox. Flush Individual Room Control for Floor Heating Systems. To be precise.

Art-Line. Absolutely Brilliant Temperature control was never so good

FLOWRETT, TA-UNI. Thermostatic valves with radiator connection system One-pipe

Halo. Thermostatic heads with built-in sensor

Thermostatic head B. Thermostatic heads Secured model designed for public buildings

Thermostatic head K. Thermostatic heads with built-in sensor and remote sensor

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

thermostatic inserts for radiators with integrated valves

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

Globo H. Ball valves Gunmetal ball valve

HERZ Regulating valve 4002

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

HERZ Differential Pressure Control Valve 4002

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

TA-MATIC. Mixing valves Thermostatic mixing valve for domestic hot water

Thermostatic heads. Thermostatic Heads For all thermostatic valve bodies and radiators with integrated valves

Connection set. Radiator connection set for thermostatic and manual operation Ø 12

Convertible radiator valve for one-pipe systems, centre distance 35 mm

Thermostatic heads. For all thermostatic valve bodies and radiators with integrated valves

manifold, for radiators

TS RD 7761 RD, 7761 RD

Meet Max. Unique AFC technology

Automatic balancing valves ASV-PV (new generation) DN 32-50

Zeparo Cyclone. Automatic air vents and separators Dirt and magnetite separator with Cyclonic technology

Unibox Individual room temperature control and limitation of return temperature in surface heating systems

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

Energy Saving Series RADICAL

Brawa-Mix Thermostatic mixing valves

THERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE PRODUCTION RANGE IRON PIPE CODE CONNECTION

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Radical CPD BIM.

HERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22

HERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien

Installation and operating instructions

Aquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes

THERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES

VHX Valve Sets with RAX Thermostatic Sensor for Designer Radiators & Bathroom Towel Rails

V2075, V2077 Flowshare Valve THERMOSTATIC TWO-WAY FLOWSHARE VALVE

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Problem-solvers The Radiator Solution Range

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Thermostatic heads. for all thermostatic valve bodies and radiators with integrated valves. To be precise.

Dynacon Eclipse. Floor Heating Manifolds Floor heating manifold with automatic flow control

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

teide termo plus+ HEATING SERIES SCOPE THERMOSTATIC VALVES SERVICE CONDITIONS COMPONENTS TECHNICAL SHEET 07/2017 IP20060 PAG. 1/9

Function series Thermo-electric actuator electric supply 230 V (ac) or 24 V (ac/dc)

Radiator Trap Radiator Valve

Systems for central heating

Say heating. Say Herz. HERZ-Supply Engineering

CONNECTION OPTIONS FOR MANIFOLDS & CONTROL UNITS

TRV & Lockshield Pack Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting with (367 CPLS) matching lockshield

Radiator Valve Program

4-way valve with thermostatic option with variable centre distance and pre-adjustment for Single pipe and Dual pipe systems.

caleffi hydronic valves page 1 of 12

SOLUTIONS GUIDE. For total efficiency

AVTI Multifunctional self - acting controller

Straight pattern thermostatic radiator valve vertical or horizontal mounting with (368T CPDLS) matching drain off lockshield

RA2000 Commercial TRVs

RA15/6T & TB Conversion Valve

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

RA 2000 Series RA 15/6T & TB Conversion Valve

2 DESCRIPTION OF SYSTEM COMPONENTS

For more information on Pegler Yorkshire visit Heating Controls. Radiator valves with new integral push-fit inlet

Tuzio Milano Towel Warmer

Thermostatic Actuators

Transcription:

Multilux -Eclipse-Set Design-Edition with two-point connection, angle and straight type, for R / and connection, with automatic flow limitation

IMI HEIMEIER / Design-Edition / Multilux -Eclipse-Set Multilux -Eclipse-Set The Multilux -Eclipse-Set is connected in -pipe systems to radiators with a lower -point connection such as bathroom radiators, design radiators, universal radiators or radiators with integrated valves. The valve has a unique integrated flow limiter that eliminates over flows. The required flow rate can be adjusted with one twist directly at the valve. The adjusted flow will not be exceed even if there are load changes in the system, due to other valves closing or during morning start up. The valve controls the flow rate independently from differential pressure. Therefore, complicated calculations to determine settings are not necessary. Centre-to-centre distance of connections 0 mm. The Multilux -Eclipse-Set is suitable for installation as angle or straight form. Thermostatic insert and shut-off insert are interchangeable. Therefore the valve is suitable for installation both left and right side of the radiator. Key features > > Integrated flow limiter eliminates over flows > > Suitable for installation as angle or straight form for pipe connection to the wall or vertical to the floor > > Thermostatic insert and shut-off insert are interchangeable the valve is suitable for installation both left and right side of the radiator > > Sets with white or chrome cover easy to install Technical description Applications area: -pipe heating systems Function: Control Flow limitation Shut-off Dimensions: DN Pressure class: PN 0 Temperature: Max. working temperature: 0 C, with cover 90 C. Min. working temperature: 0 C Flow range: The flow can be stepless pre-set within the range: 0-0 l/h. Delivery setting 0 l/h. Differential pressure (ΔpV): Max. differential pressure: 60 kpa (<0 db(a)) Min. differential pressure: 0 00 l/h = 0 kpa 00 0 l/h = kpa Materials: Valve body: Corrosion resistant Gunmetal. O-rings: EPDM rubber Valve disc: EPDM rubber Return spring: Stainless steel Valve insert: Brass, PPS (polyphenylsulphide) Spindle: Niro-steel spindle with double O-ring sealing. Cover: ABS Surface treatment: Valve body gunmetal, fittings are nickelplated. Marking: THE and II+ Designation. Protection cap orange. Radiator connection: Adapters for R/ and G/, for radiator connections. Tolerance compensation ±,0 mm with special union nuts and flexible flat seal system for installation free of tension. Pipe connection: G/ male thread for compression fittings for plastic, copper, precision steel or multilayer pipe. Connection to thermostatic head and actuator: HEIMEIER M0x. Thermostatic head DX: Thermostatic head DX with closed graduation cap and liquidfilled thermostat. High actuating force, minimum hysteresis, optimum closing time. Stable control response even with minor calculated p-band variations (< K). Conforming to German EnEV and/or DIN V 70-0. Setting numbers. Frost protection. Temperature range 6 C to 8 C.

Construction Multilux -Eclipse Installation as angle type / Installation as straight type. R/ Radiator connection. G/ Radiator connection. G/ end caps. Thermostatic insert with automatic flow limiter. Return shut-off Function Eclipse flow limiter A regulating part is set to the calculated control rate by turning the digit cap with the setting key or an mm end wrench. If the flow rate increases at the valve the rising pressure moves the sleeve, thus constantly limiting the flow to the set value. The set flow rate is therefore never exceeded. If the flow rate drops below the set value a spring presses the sleeve back to its original position. Application The Multilux -Eclipse-Set is connected in -pipe systems to radiators with a lower -point connection such as bathroom radiators, design radiators, universal radiators or radiators with integrated valves etc.. The Multilux -Eclipse-Set is suitable for installation as angle or straight form. The required design flow for each radiator is set directly on the Multilux -Eclipse valve. This automatic flow limitation is done with a twist and the adjusted flow will then not be exceeded. Even if there is an oversupply of pressure, due to load changes in the system, for example other valves closing or during morning start up, Eclipse will guarantee the requested flow. The valve controls the flow rate independently from differential pressure. Therefore, complicated calculations to determine settings are not necessary. The pressure loss of pipings in old systems does not have to be determined in renovation projects. Only the heating capacity and the resulting max. flow rate have to be determined (see setting chart). The min. differential pressure has to be at the most unfavourable valve. If necessary, it can be measured in order to optimize pump settings. Thermostatic insert and shut-off insert are interchangeable. Therefore the valve is suitable for installation both left and right side of the radiator. The Multilux -Eclipse-Set is suitable for universal applications thanks to its connection options for Rp / and G/ radiator connections. Note the flow direction! See also the installation and operating instruction. Noise behaviour To ensure low-noise performance, the following conditions must be met: The differential pressure above Eclipse should not exceed 60 kpa = 600 mbar = 0,6 bar (<0 db(a)). Flow must be correctly adjusted. The system must be completely deaerated.

IMI HEIMEIER / Design-Edition / Multilux -Eclipse-Set Sample application Multilux -Eclipse with bathroom radiator Multilux -Eclipse-Set, white RAL 906 Multilux -Eclipse-Set, chrome Notes To avoid damage and the formation of scale deposit in the hot water heating system, the composition of the heat transfer medium should be in accordance with the VDI guideline 0. For industrial and long-distance energy systems, see the applicable codes VdTÜV and 66/AGFW FW 0. A heat transfer medium containing mineral oils, or any type of lubricant containing mineral oil can have extremely negative effects and usually lead to the disintegration of EPDM seals. When using nitrite-free frost and corrosion resistance solutions with an ethylene glycol base, pay close attention to the details outlined in the manufacturers documentation, particularly concerning concentration and specific additives. The thermostatic valve bodies can be used with all IMI Hydronic Engineering thermostatic heads and thermal or motorized actuators. The optimal tuning of the components guarantees maximum safety. When using actuators from other manufacturers, make sure that the pressure power is appropriate for thermostatic valve bodies with soft sealing valve discs.

Operation Flow setting Stepless setting between to (0 to 0 l/h). The setting is changed using a special setting key (article No. 90-0.) or an mm end wrench, to ensure tamper proof setting. Place the setting key on the valve insert. Turn the setting tool so that desired setting value is pointing at the index* of the valve body (see fig.). Remove the key or mm end wrench. The valve is now set. Front-end and lateral visibility *) mm *) Index Setting l l l l l l l 0 l l l l l/h 0 0 0 0 0 60 70 80 90 00 0 0 0 0 0 P-band [xp] max. K. P-band [xp] max. K up to 90 l/h. Diagram l/h 60 db(a)* ) 0 db(a)* ) max. Lowest flow tolerances 0 0 00 80 60 0 0 min. 0 0 0 0 0 0 0 60 kpa 0 0 0 70 90 0 0 0 l/h 0-00 l/h: 0 kpa 00-0 l/h: kpa *) P-band [xp] max. K.

IMI HEIMEIER / Design-Edition / Multilux -Eclipse-Set Setting table Setting values with different radiator performances and system differential temperatures 0 6 7 8 9 0 6 7 8 9 0 0 6 7 8 9 0 0 0 6 6 7 8 8 9 9 00 0 6 6 7 7 7 8 8 9 0 p min. 0-00 l/h = 0 kpa p min. 00-0 l/h = kpa Q = Radiator performance Δt = System differential temperature Δp = Differential pressure Sample: Q = 000 W, Δt = K Setting value: 6 ( 60 l/h) Articles Multilux -Eclipse-Set Multilux -Eclipse-Set consists of: Multilux Eclipse thermostatic valve body R / radiator connections radiator connections End caps for pipe connection Cover Thermostatic head DX EAN Article No White RAL 906 0098 9690-8.000 Chrome-plated 0098 9690-9.000 6

Accessories Setting key for Eclipse. Color orange. EAN Article No 00977 90-0. Compression fitting for copper or precision steel pipe according to DIN EN 07/00-/. Connection male thread according to DIN EN 6 (Eurocone). Metal-to-metal joint. Brass nickel-plated. With a pipe wall thickness of 0.8- mm insert supporting sleeves. Heed pipe manufacturer s technical advice. Ø Pipe EAN Article No 00 8-. 0067 8-. 6 009 8-6. 8 008 8-8. Supporting sleeves for copper or precision steel pipe with a wall thickness of mm. Ø Pipe L EAN Article No,0 00706 00-.70 6,0 00797 00-.70 6 6, 0089 00-6.70 8 6,8 0088 00-8.70 Compression fitting for copper or precision steel pipe according to DIN EN 07/00-/. Connection male thread according to DIN EN 6 (Eurocone). Soft sealed, max. 9 C. Nickel-plated brass. Ø Pipe EAN Article No 008 -. 8 00606-8. Compression fitting for Alu/PEX multi-layer pipe according to DIN 686. Connection male thread according to DIN EN 6 (Eurocone). Nickel-plated brass. Ø Pipe EAN Article No 6x 007-6. Compression fitting for plastic pipe according to DIN 76, ISO 008. PE-X: DIN 689/689, EN ISO 87; PB: DIN 6968/6969. Connection male thread according to DIN EN 6 (Eurocone). Nickel plated brass. Ø Pipe EAN Article No x 0068 -. 6x 0086-6. 7x 009-7. 8x 000-8. 0x 008-0. Double rosette Dividable in the middle, made of plastic, white, for various pipe diameters. Centre distance 0 mm. Overall height max. mm. EAN Article No 00070 00-00.09 Replacement thermostatic insert with automatic flow limiter for Eclipse. EAN Article No 00909 90-0.00 7

IMI HEIMEIER / Design-Edition / Multilux -Eclipse-Set Dimensions R/ radiator connection R / R / SW 0 9 SW 6, 0,, G/ radiator connection. SW 0 0 SW, 0,,. Contact surface, upper edge seal 8,, 0, 7 *) setting at mm = 0,09 inch The products, texts, photographs, graphics and diagrams in this document may be subject to alteration by IMI Hydronic Engineering without prior notice or reasons being given. For the most up to date information about our products and specifications, please visit www.imi-hydronic.com. -8.8 EN Multilux -Eclipse-Set 06.06