Your reference Your message dated Our reference Braunschweig, Mat / Bön 8 April 2016

Similar documents
Assessment Report Construction Product Regulation* * CPR - REGULATION (EU) No 305/2011

Frequently Asked Questions on the Construction Products Regulation (CPR) - Enterprise and Industry

TFI Report Classification

1. Terms defined in the Construction Products Regulation (CPR)

Guidance from the Group of Notified Bodies for the Construction Products Directive 89/106/EEC

TFI Report Classification

DECLARATION OF PERFORMANCE. No EN. Post-installed fastening in cracked or uncracked concrete, see appendix, especially Annexes B 1 to B 6

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

Guidance from the Group of Notified Bodies for the Construction Products Regulation 305/2011/EU

The New EU-Regulation on Construction Products

DECLARATION OF PERFORMANCE. No EN

Implementing the Construction Products Regulation (EU) 305/2011

DECLARATION OF PERFORMANCE. No EN

DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE. DoP: 0094 for Injection System fischer FIS V (Bonded anchor for use in concrete) EN

DECLARATION OF PERFORMANCE. No EN

DECLARATION OF PERFORMANCE. DoP: 0124 for fischer Ceiling Anchor FDZ (Metal anchors for use in concrete (light-duty type)) EN

DECLARATION OF PERFORMANCE. No EN

The Danish Energy Agency will carry out inspections in June 2013

Stanley Black & Decker Deutschland GmbH Richard-Klinger-Straße Idstein DEUTSCHLAND. Manufacturing plant Manufacturing Plant 4 and Plant 9

For structural use in all types of construction works according to EN

DECLARATION OF PERFORMANCE. No EN. Annexes B 1 to B 4

DECLARATION OF PERFORMANCE. No EN. Post-installed fastening in cracked or uncracked concrete, see appendix, especially Annexes B 1 to B 4

CE marking of noise barriers and foundations

Declaration of Conformity Declaration of Performance Notes

Co-ordination of the Group of Notified Bodies for the Construction Products /Regulation 305/2011/EU

DECLARATION OF PERFORMANCE. DoP: 0135 for fischer injection system FIS EM Plus (Bonded anchor for use in concrete) EN

Technical Bulletin CE marking: from 1st July 2013

DECLARATION OF PERFORMANCE. No EN

CERTIFICATE. Conformity of the Factory Production Control CPR TÜVRh

CE marking of fire-resistant doors the right way!

CE marking of industrial doors under the CPR Michael Skelding, Secretary and General Manager Door and Hardware Federation

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

Regulation 574_2014: Annex III CPR. and. Regulation 568_2014: Annex V CPR

DECLARATION OF PERFORMANCE. No EN

CE Marking for Fire Resistant doors. The future EN Agustín Garzón Cabrerizo Technical Director Fire Resistance Lab.

DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE. No EN. Post-installed fastening in cracked or uncracked concrete, see appendix, especially Annexes B 1 to B 9

DECLARATION OF PERFORMANCE 1 N. For structural use in all types of construction works according to EN

CE MARKING OF WOOD-BASED PANELS

Belcom Cable excellence engineered through quality. CPR Construction Products Regulation

CONSTRUCTION PRODUCTS REGULATION MOLEX CES COPPER AND FIBRE CABLE

Council Directive 93/68/EEC of 22 July 1993 amending Directives

GNB-CPR Position Paper: Issuance of certificates under CPR

DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE

CERTIFICATE. AXITEC GmbH Otto-Lilienthal-Str. 5 D Böblingen ISO 9001:2008

COMMISSION DELEGATED REGULATION (EU)

The New Generationn of Firedoors

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034

COMMISSION DELEGATED REGULATION (EU) /... of

in accordance with Annex 111 of Regulation (EU) No. 305/2011 ( Construction Products Regulation ) ULTRA PROFLEX SP+ES GREY

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

Test Report No

DID YOU GET USED TO THE NEW CPR? HERE S A QUICK REVIEW!

COMMISSION DELEGATED DECISION (EU) / of XXX

ETICS and the EU Internal Market The European framework. G. Katsarakis European Commission, DG GROWTH Unit C-1: Clean technologies and products

CPR Guide: EU Rules Practical Impact

Construction Products Directive

Council of the European Union Brussels, 21 March 2017 (OR. en) Mr Jeppe TRANHOLM-MIKKELSEN, Secretary-General of the Council of the European Union

Approved Sound Proofed Systems

CPR Guide: EU Rules Practical Impact

Üntel is ready for CPR

EUROPEAN TECHNICAL ASSESSMENT

Reaction to fire classification report No B

RADAR REFLECTOR STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

Guideline Construction Products Regulation (EU) 305/20122

54. IWK Internationales Wissenschaftliches Kolloquium International Scientific Colloquium

YOUR GUIDE TO UNDERSTANDING CPR

European Technical Assessment. ETA-18/0213 of 17 May English translation prepared by DIBt - Original version in German language.

Lawnmowers, pedestrian controlled (combustion engine powered)

European Technical ETA-07/0332 Assessment of 30 January 2015 General Part

THE IMPORTANCE OF THE RESPONSIBLE WELDING COORDINATOR IN STRUCTURAL METALWORKS ACCORDING TO THE REQUIREMENTS OF EN CE MARKING

Your Key to achieving C.E Marking Compliance

English translation prepared by DIBt - Original version in German language. Nails

Solar Keymark in Europe. DI (FH) Gundula Tschernigg AIT Austrian Institute of Technology

Implementation of Harmonized Standards - A Member State Perspective. Norway

Construction Products Directive

Additional reaction to fire classification report No H

Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

EUROPEAN TECHNICAL ASSESSMENT

Centexbel. General certification regulations. Construction products

Construction Products Regulation (CPR) and BS 6701

European Technical ETA-12/0607 Assessment of 18 January 2018 General Part

BRL-K21030/02 5 August Certification of Alarm Communication. Certification Alarm Transmission Systems (ATS) Alarm Transmission Systems

European Technical ETA-10/0305 Assessment of 6 December 2017 General Part

European Technical Assessment. ETA-17/0624 of 8 September English translation prepared by DIBt - Original version in German language

DECLARATION OF PERFORMANCE ref. no

Lawnmowers (pedestrian controlled electric mains-powered)

See product BS EN :2010

Declaration of Performance

Classification Report Reaction to fire of building elements DIN EN :2007. Class E

CE marking: implications for timber products

CONSTRUCTION PRODUCTS REGULATION 2011 DECLARATION OF PERFORMANCE

Cylinder Mortice Dead lock Lockcase(mm) A=87 Backset (mm) B=55. Follower (mm) 8 Latch Bolt

Europacable FAQ on CPR Status: 26/01/17

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

The Danish Energy Authority to carry out inspections in June and July 2012

Declaration of performance ( DoP ) :

Transcription:

Fraunhofer WilhelmKlauditzInstitut Bienroder Weg 54 E 38108 Braunschweig Germany LV1016 Riga Fraunhofer Institute for Wood Research WilhelmKlauditzInstitut WKI Director Prof. Dr.Ing. Bohumil Kasal Head of the Testing, Supervision and Certifying Body Dipl.Ing. Harald Schwab Bienroder Weg 54 E 38108 Braunschweig Germany Dipl.Ing. (FH) Maik Matolin Project manager Quality Assessment Phone +49 (0) 531 2155 263 Fax maik.matolin@wki.fraunhofer.de www.wki.fraunhofer.de Your reference Your message dated Our reference Braunschweig, Mat / Bön 8 April 2016 Report No. QA 2016 0935 Type of report: Manufacturer: Inspection report of continuous inspection of factory and factory production control according EN 3262 of woodbased panels for use in construction in compliance with EN 13986 in first halfyear 2016, of the certifications noted under 1. Task LV1016 Riga Content of report: 1. Task 2. Execution 3. Results 4. Assessment page 2 page 4 page 4 page 5 The report comprises 5 pages. This report is not permitted to be published incompletely. A publication in extracts is in any case subject to the previous consent of Fraunhofer Institute for Wood Research, Wilhelm KlauditzInstitut (WKI), Bienroder Weg 54E in 38108 Braunschweig (Germany). FraunhoferGesellschaft zur Förderung der angewandten Forschung e.v., München Executive Board Prof. Dr.Ing. habil. Prof. E.h. Dr.Ing. E.h. mult. Dr. h.c. Reimund Neugebauer, President Prof. (Univ. Stellenbosch) Dr. rer. pol. Alfred Gossner Prof. Dr. rer. publ. ass. iur. Alexander Kurz Cheques and transfers payable to: Deutsche Bank, München Account 752193300 BLZ 700 700 10 IBAN DE86 7007 0010 0752 1933 00 BIC (SWIFTCode) DEUTDEMM V.A.T. Ident No. DE129515865 Tax Number 143/215/20392

Page 2 to 5 Report No. QA20160935 1. Task For construction products according to EN 13986 woodbased panels for use in construction characteristics, evaluation of conformity and marking a system of assessment and verification of constancy of performance according to Regulation 305/2011/EU of the European Parliament and of the Council of 9 March 2011 (the Construction Products Regulation or CPR) shall be applied. The Regulation 305/2011/EU differentiates several systems of assessment and verification of constancy of performance. According to system 1 a notified body shall carry out an initial type testing, an initial inspection of the manufacturing plant and of factory production control as well as a continuous surveillance, assessment and evaluation of factory production control. According to system 2+ a notified body shall carry out an initial inspection of the manufacturing plant and of factory production control as well as a continuous surveillance, assessment and evaluation of factory production control. According to system 4 there are no tasks for the notified body. In individual cases a continuous surveillance, assessment and evaluation of factory production control was ordered by manufacturers on voluntary basis. According to the certification and supervision contracts: Nr. 0777 dated 10 February 2010; Nr. 0778 dated 10 February 2010; Nr. 0779 dated 10 February 2010; Nr. 0790 dated 17 May 2010; Nr. 0797 dated 4 June 2010; Nr. 0945 dated 13 May 2013; Nr. 0960 dated 9 January 2014 between the manufacturer and the FraunhoferInstitute for Wood Research, WilhelmKlauditzInstitut (WKI), as notified body no. NB 0765, the inspection of the factory and of the factory production control for the following product types was carried out: Product 1: EN 300, OSB/2; DIBt 100, E1 OSB 2 ECO 0765CPD777 Product 2: EN 300, OSB/3; DIBt 100, E1 OSB 3 ECO 0765CPD778 Product 3: EN 300, OSB/4; DIBt 100, E1 OSB 4 ECO 0765CPD779 * current version

Page 3 to 5 Report No. QA20160935 Product 4: particleboard, melamineureaformaldehyde (MUF), unfaced EN 312, P4/P6 > 12 mm 25 mm Particleboard type P4/P6 0765CPD790 Product 5: particleboard, melamineureaformaldehyde (MUF), unfaced EN 312, P5; DIBt 100, E1 25 mm Particleboard type P5 0765CPD797 Product 6: particleboard, melamineureaformaldehyde (MUF), unfaced EN 312, P6 22 mm Fast Floor P6 4TG 0765CPR0945 Product 7: particleboard, melamine urea formaldehyde (MUF), unfaced EN 312, P5 22 mm Fast Floor P5 4TG 0765CPR0960 The manufacturer shall establish, document and maintain a factory production control system to ensure that the products placed on the market are conform to the stated performance characteristics. The continuous surveillance of the factory production control shall cover all the performance characteristics relevant to the intended application (see EN 13986, Tables 1 to 7).

Page 4 to 5 Report No. QA20160935 2. Execution The inspection of the factory and of the factory production control took place on 16 February 2016 on the manufacturer's production site: LV1016 Riga As representative of the manufacturer was present: Ms. Shanna Sirokvasha Laboratory Manager The inspection was carried out by the WKI employee Dipl.Ing. (FH) Oliver Meistring. The manufacturer made available the latest minutes of the factory production control. 3. Results The manufacturer runs a quality management system. The manufacturer has introduced relevant quality control systems according to technical specifications. The manufacturer possesses all relevant standards, process descriptions and working instructions which are accessible for the personnel. The manufacturer has specified the raw materials and checks their ability for the production. The manufacturer has adequate production facilities to produce the supervised products. The manufacturer records relevant production parameters, which allow tracing of production errors. Samples are taken according to statistical aspects and in required quantity. Tests are performed within the specified period of time after production. The manufacturer proves that tests become carried out separately for each product type and production line. Test results of the factory production control can be evaluated separately for each product type and production line. The manufacturer calculates the average value and 5% respectively 95% quantile values of the last 30 results of the factory production control tests. The testing equipment is complete and regularly maintained and calibrated. Reagents and additives are complete, checked for their durability and stored safely. The laboratory personnel are trained and have relevant experience for performing quality control tests. A procedure for handling nonconform products is implemented and followed by responsible personnel. The manufacturer marks the products correctly and keeps necessary product documentation. The manufacturer has issued a declaration of performance for each CE marked product.

Page 5 to 5 Report No. QA20160935 Deviation: The fire reaction class for 8 mm OSB shall be corrected in the DoP. Furthermore the minimum density requirements shall be respected in the product specification. Additional information: A training plan for new personnel shall be issued. In present case V. Galaks joined a new postition (OSB supervisor) without having a training plan shall be issued. 4. Assessment The factory production control for the products mentioned in section 1 fulfils the requirements of EN 326 2:2000 "woodbased panels sampling, cutting and inspection: quality control in the factory". According to the indented use of the products the performance characteristics specified in EN 13986 "woodbased panels for use in construction characteristics, evaluation of conformity and marking" are under control. The factory laboratory carrying out the factory production control meets the requirements. Dipl.Ing. (FH) Maik Matolin Official in charge Dipl.Ing. Harald Schwab Head of Testing, Supervision and Certifying Body