SPCIFICTIOS Model HWP 255RKT Item o. (Standard / Opposite Hand) 509-255-001 / 509-255-011 Cooling capacity (net) to S/ZS 3823 T1 24.7 kw Heating capacity H1 23.0 kw lectrical input - cooling 5.8 kw lectrical input - heating 5.4 kw R / R (cooling) 4.29 / 4.28 COP / COP (heating) 4.31 / 4.30 Unit Controller Refrigerant R410 Refrigerant charge 3.4 kg Compressor type scroll connections 1" male SP ominal WT on cooling 30 C ominal WT on heating 21 C ominal Flow @ WT LWT = 5k 1.53 l/s ntering system pressure drop @ nominal flow 48 kpa (7 psi) Min. water temp. Heat cycle at nominal flow 10 C Min. water temp. Cool cycle at nominal flow 15 C Min. water temp. Cool cycle with water flow control valve 5 C Max. WT Heat cycle at nominal flow 30 C Max. WT Cool cycle at nominal flow 50 C Min. water flow @ nominal WT 0.42 l/s Max. water pressure excluding hoses 3200 kpa (464 psi) Power supply 3 ph. 40 ac 50Hz Compressor run amps at rating cond. 8.5 /ph. Indoor fan motor size 750 W Indoor fan motor (1ph.) - full load 6.5 Control circuit breaker (internal) 10 Running amps (total system) 13.5 / 8 / 8 Max. running amps (total system) 18.5 / 13 / 13 et weight 190 kg ccessories: Spring mounts supplied hoses 800mm long, rated 2070 kpa (300 psi) 1" female SP, supplied Replacement filter U2 rated 119-000-104 1398x405x13 Condensate lift-pump 507-003-010 Optional: ST-3 Room temperature controller 201-000-146 TZT-100 Room temperature controller 201-000-350 Refer to temperzone for other options, eg remote sensors 17013
IMSIOS (mm) PROJCTIO HWP 255RKT Standard ot to Scale 500 MI. CLRC W lectrical ox X POIT LOS (kg) W X Y Z 500 MI. CLRC 39 55 63 33 ote: Fan motor can be accessed from panel above, below or sides; no more than two panels at once. Z 67 Y 79 78 HWP 255RKT Opposite Hand 500 MI. CLRC POIT LOS (kg) W X Y Z 63 39 33 55 ote: Fan motor can be accessed from panel above, below or sides; no more than two panels at once. 500 MI. CLRC W lectrical ox X Z Y 79 67 78 OT Specifications are subject to change without notice due to the manufacturer's ongoing research and development programme.
LCTRICL TL2W1 xternal Protection & Isolation Pump Verification ry Contacts If Pump Verification Option fitted remove this link L1 L2 L3 T1 T2 T3 T4 T5 T6 T7 Flow 1 Flow 2 1 6-6- CC TH3 TH2 CM PRC Condensate Pump Flow Control Valve 2R /O Relay 2 /O Relay 1 FR /O T8 Pump 1 Pump 2 ctive C 7-7- CP LU WHT (LOW) R (M) 1 M R (HIGH) IFM IP switch settings JUMPR settings IP switch On/Off 1,7,9,13,14 On ll Others Off Off RV SCRIPTIO Initial Release C temperzone Ltd 2017 Position Jumper T O OT SCL - SK PPROV PFCC removed from legend 19-04-17... C FR & SR now fitted as standard 3941 25-05-17... ow renamed to HWP 255 19-06-17... Client Wiring Sensors (S) / Transducers (T) ame Type Colour L ischarge Temp S R SL Suction Temp S WHIT IC Indoor Coil S YLLOW LPT Low Pressure T HPT High Pressure T rawn: pprvd:... ate: 04-01-17 SR /O 24VC/VC Optional 0-1 Sensors and Transducer *Refer Table Temp Sensors (Refer to table) 1 1 Modbus slave port for MS (monitoring or control option) FLT UX HI M LO C1 L SL 2 2 Modbus master port for optional T/stat (TZT100/ST-3) HPT LPT M Pressure sensors I OC IC V1 V2 1 2 3 SC O CP4W1 CP2W1 0-1 to Regulating Valve If Condensate Float Switch Option fitted remove this link Condensate Float Switch (ormally closed) Remote On/Off ry Contact C 1- If Remote On/Off option fitted remove this link RV 1- CP CPCITOR CC COTROL CIRCUIT RKR CM PRSSOR MOTOR PRSSOR COTCTOR CP2W COCTOR PLUG 2 WY CP4W COCTOR PLUG 4 WY V LCTROIC XPSIO VLV 2R XV2 RLY OR FR FULT RLY OR Title: rawing o: Rev: 291-002-186 HWP 255RKT Wiring Schematic TH RTH IFM IOOR F MOTOR PRC PHS ROTTIO COTROLLR PHS ROTTIO RLY RV RVRSIG VLV SR STTUS RLY OR T TRMIL LOCK TL2W TRMIL LOCK LIK 2 WY UIT COTROLLR 8 SHT 1 OF 1 XV1 XV2 I#1 I#1 C2 HT CP I#2 I#2 HIGH M LOW C3 C4 L 5 VF VC V (Sanhua) P1 Refer to IP S/W settings isplay SW1 SW2 SW3
003-000-101 06/17 www.temperzone.biz temperzone limited 2017
SPCIFICTIOS Model HWP 255CKT HWP 255CKT Item o. - Standard 509-255-101 509-255-102 Item o. - Opposite Hand 509-255-111 509-255-1 Cooling capacity (net) to S/ZS 3823 T1 24.7 kw Heating capacity - lectric heat n/a.0 kw lectrical input - cooling 5.5 kw lectrical input - heating n/a 13.2 kw R / R (cooling) 4.48 / 4.46 Unit Controller Refrigerant Refrigerant charge Compressor type connections R410 3.0 kg scroll 1" male SP ominal WT on cooling 30 C ominal Flow @ WT LWT = 5k ntering system pressure drop @ nominal flow 1.53 l/s 48 kpa (7 psi) Min. water temp. Cool cycle at nominal flow 15 C Min. water temp. Cool cycle with water flow control valve 5 C Max. WT Cool cycle at nominal flow 50 C Min. water flow @ nominal WT Max. water pressure excluding hoses Power supply Compressor run amps at rating cond. Indoor fan motor size Indoor fan motor (1ph.) - full load Control circuit breaker (internal) 0.42 l/s 3200 kpa (464 psi) 3 ph. 40 ac 50Hz 8 750 W 6.5 10 Running amps (total system) 13 / 8 / 8 23 / 17.5 / 17.5 Max. running amps (total system) 19 / 13 / 13 24 / 17.5 / 17.5 et weight 190 kg 190 kg ccessories: Spring mounts hoses 800mm long, rated 2070kPa (300psi) Replacement filter supplied 1" female SP, supplied 119-000-104 1398x405x13 Condensate lift-pump 507-003-010 Optional: ST-3 Room temperature controller 201-000-146 TZT-100 Room temperature controller 201-000-350 Refer to temperzone for other options, eg remote sensors Tested in accordance with S/ZS 3823 17013
IMSIOS (mm) PROJCTIO HWP 255 CKT/CKT Standard ot to Scale 500 MI. CLRC W lectrical ox X POIT LOS (kg) W X Y Z 500 MI. CLRC 39 55 63 33 ote: Fan motor can be accessed from panel above, below or sides; no more than two panels at once. Z 67 Y 79 78 HWP 255 CKT/CKT Opposite Hand 500 MI. CLRC POIT LOS (kg) W X Y Z 63 39 33 55 ote: Fan motor can be accessed from panel above, below or sides; no more than two panels at once. W lectrical ox X Z Y 79 500 MI. CLRC 78 67 OT Specifications are subject to change without notice due to the manufacturer's ongoing research and development programme.
LCTRICL TL2W1 xternal Protection & Isolation Pump Verification ry Contacts If Pump Verification Option fitted remove this link L1 L2 L3 T1 T2 T3 T4 T5 T6 T7 Flow 1 Flow 2 1 6-6- CC TH3 TH2 CM PRC Condensate Pump Flow Control Valve 2R /O Relay 2 /O Relay 1 FR /O T8 Pump 1 Pump 2 ctive C 7-7- CP LU WHT (LOW) R (M) 1 M R (HIGH) IFM IP switch settings JUMPR settings IP switch On/Off 1,7,9,13,14 On ll Others Off Off RV SCRIPTIO Initial Release C temperzone Ltd 2017 Position Jumper T O OT SCL - SK PPROV PFCC removed from legend 19-04-17... C FR & SR now fitted as standard 3941 25-05-17... ow renamed to HWP 255 19-06-17... Client Wiring Sensors (S) / Transducers (T) ame Type Colour L ischarge Temp S R SL Suction Temp S WHIT IC Indoor Coil S YLLOW LPT Low Pressure T HPT High Pressure T rawn: pprvd:... ate: 09-02-17 SR /O 24VC/VC Optional 0-1 Sensors and Transducer *Refer Table Temp Sensors (Refer to table) 1 1 Modbus slave port for MS (monitoring or control option) FLT UX HI M LO C1 L SL 2 2 Modbus master port for optional T/stat (TZT100/ST-3) HPT LPT M Pressure sensors I OC IC V1 V2 1 2 3 SC O CP4W1 CP2W1 0-1 to Regulating Valve If Condensate Float Switch Option fitted remove this link Condensate Float Switch (ormally closed) Remote On/Off ry Contact C 1- If Remote On/Off option fitted remove this link 1- CP CPCITOR CC COTROL CIRCUIT RKR CM PRSSOR MOTOR PRSSOR COTCTOR CP2W COCTOR PLUG 2 WY CP4W COCTOR PLUG 4 WY V LCTROIC XPSIO VLV 2R XV2 RLY OR FR FULT RLY OR Title: rawing o: Rev: 291-002-209 HWP 255CKT Wiring Schematic TH RTH IFM IOOR F MOTOR PRC PHS ROTTIO COTROLLR PHS ROTTIO RLY SR STTUS RLY OR T TRMIL LOCK TL2W TRMIL LOCK LIK 2 WY UIT COTROLLR 8 SHT 1 OF 1 XV1 XV2 I#1 I#1 C2 HT CP I#2 I#2 HIGH M LOW C3 C4 L 5 VF VC V (Sanhua) P1 Refer to IP S/W settings isplay SW1 SW2 SW3
TH2 TH3 T1 T2 T3 TL2W1 SR V (Sanhua) HC1 HC2 Optional 0-1 T4 L1 T5 Sensors and Transducer *Refer Table 24VC/VC /O H1 H2 H3 L2 T6 L3 VC VF HI M LO C1 5 xternal Protection & Isolation I#2 I#2 I#1 I#1 C2 HT CP Modbus slave port for MS (monitoring or control option) 1 1 UX XV2 XV1 FR PRC CC Refer to IP S/W settings FLT /O Modbus master port for optional T/stat (TZT100/ST-3) 2 2 SW1 SW2 2R Temp Sensors (Refer to table) P1 Condensate Pump L SL isplay /O Relay 2 0-1 to Regulating Valve Pump Verification ry Contacts If Condensate Float Switch Option fitted remove this link V1 V2 I M SW3 Relay 1 OC IC /O Flow Control Valve CM 6- CP4W1 1 2 Pressure sensors HPT LPT 6- T7 Flow 1 Flow 2 Condensate Float Switch (ormally closed) 3 SC C3 LOW M F -0 F -0 G -1 HIGH 1 CP2W1 If Pump Verification Option fitted remove this link Remote On/Off ry Contact O L C4 C 6- If Remote On/Off option fitted remove this link HST C 6-1- T8 Pump 1 Pump 2 t ctive HC2 1- MST t T9 HC1 CP G -4 4-4- WHT (LOW) R (M) LU 1 M R (HIGH) IFM JUMPR settings IP switch settings FR FULT RLY OR TH RTH HST HIGH TMPRTUR SFTY THRMOSTT IFM IOOR F MOTOR PRC PHS ROTTIO COTROLLR PHS ROTTIO RLY SR STTUS RLY OR T TRMIL LOCK TL2W TRMIL LOCK LIK 2 WY UIT COTROLLR 8 CP CPCITOR CC COTROL CIRCUIT RKR CM PRSSOR MOTOR PRSSOR COTCTOR CP2W COCTOR PLUG 2 WY CP4W COCTOR PLUG 4 WY V LCTROIC XPSIO VLV 2R XV2 RLY OR H LCTRIC HT HC LCTRIC HT COTCTOR Sensors (S) / Transducers (T) ame Type Colour M Fast Temp Sensor S LCK L ischarge Temp S R SL Suction Temp S WHIT Position Jumper IP switch On/Off 1,3,4,7,9,13,14 On ll Others Off Off PPROV T C IC Indoor Coil S YLLOW RV SCRIPTIO Initial Release LPT Low Pressure T HPT High Pressure T PFCC removed from legend 19-04-17... C FR & SR now fitted as standard 3941 25-05-17... ow renamed to HWP 255 19-06-17... Title: rawing o: Rev: 291-002-187... ate: 04-01-17 rawn: temperzone Ltd 2017 Client Wiring SHT 1 OF 1 HWP 255CKT Wiring Schematic pprvd: O OT SCL - SK 003-000-100 06/17 www.temperzone.biz temperzone limited 2017