Item No. (Standard / Opposite Hand) /

Similar documents
Item No. (Standard / Opposite Hand) /

Item No. (Standard/Opposite Hand) /

Item No. (Standard/Opposite Hand) /

Unit Controller (UC8) Quick Reference Operation and Fault Diagnosis

DUCTED WATER COOLED PACKAGED AIR CONDITIONERS HWP models (c/w UC8) Installation & Maintenance

S D HWP 77, 96. Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance. Fig. 1 Nomenclature. Fig.

OPA RKTG-P (ECO) c/w UC8 Air Cooled Packaged Units - Reverse Cycle - R410A Installation & Maintenance

Water Cooled Units HWP 370, 445. Cooling Capacity 36.6kW kW. Heating Capacity 34.9kW kW

OPTIONAL SPRING MTG HANGING CENTRES WATER CONN'S: TWO BSP MALE. 19 mm (3/4") ELECTRICAL CONDUIT HOLES ACCESS PANEL OUT (WATER) IN 485 MOUNTING

REVERSE CYCLE DUCTED SPLIT SYSTEMS (ISDL/OSA c/w UC8/IUC) Installation & Maintenance

S Y D. HWP 35, 47, 58 (c/w EC Motor & UC7 Controller) Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance

Water Cooled Air Conditioners Applications Manual

UNIT CONTROLLER 8 (UC8) Troubleshooting guide

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

ENGINEERING SPECIFICATIONS

ENGINEERING SPECIFICATIONS

R 407 C. > in industrial application. Always very much appreciated for special installations these units shown their powers :

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

Refrigerant Cycle. Performance Data 1) Electric. Acoustic Pressure Level. Compressor. Connections, Dimensions

Technical Data Ducted Three Phase Split System Air Conditioner

AQUASNAP JUNIOR 30RHV

Technical Data ISU Series. Underceiling/Console Split System Air Conditioners kw 15 kw

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

Technical Data OPA RKTBG-P. Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

HT V2 HT Split

EC Motor Fan Coil Units. IMDL-Y Series l/s

R4H4. Product Specifications

Cooling Capacity 3.5kW kW. Heating Capacity 4.4kW kW. Air Conditioning. Giving you complete control

Technical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS

E1 Electrical Fundamentals. # 4 - Symbols and Wiring Diagrams

R4H4. Product Specifications

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

SINGLE-PACKAGE ROOFTOP HEAT PUMP UNITS INDEX. VOLTAGE (3 Ph, 60 Hz) ACCESSORIES

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

Application and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A ), 120/208/240/1/60, R404A, LT/MT APPS

EC Motor Fan Coil Units. IMDL-Y Series l/s

GUIDE SPECIFICATIONS AQUARIUS ii

Technical data DHP-R. A brine-to-water building heat pump in power outputs

... RTU. Packaged Air to Air Heat Pump...

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Air Cooled Scroll Chiller / Heat Pump

Technical Manual. Multi Split Trio Quattro DCI REFRIGERANT R410A HEAT PUMP

Ducted Split System Air Conditioners Technical Data

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

Ducted Split System Air Conditioners Technical Data

Self-Contained & Split System Reverse Cycle Air Conditioners Models

Duct Free Systems Product Data Digest ¾ to 5 Nominal Tons

RSMV Technical Guide

50VZ (40PZ/38VZ) Vertical Air-Cooled Split-System Cooling Units. Nominal cooling capacity kw

WDH WDH. Ground source heat pumps OTHER VERSIONS ACCESSORIES

Commercial High-Efficiency Condensing Units

DANFOSS OPTYMA PLUS INVERTER UNITS

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

GENERAL NOTES SYMBOLS LEGEND SALES PERSON MASON LASTER PROJECT MANAGER REVISIONS DALLAS, TX ALDI #000 MAIN STREET NEW R1.

N4H4. Product Specifications

Installation, Start-Up and Service Instructions

RTHE Series R Helical Rotary Liquid Chiller Tons 60Hz

RBR Relay Boxes. Installation Manual. Industrial & Commercial Heating Systems. Doc Ref: M406 Issue 1.

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

General Description. Operation

2009 Panasonic Marketing Europe GmbH / All rights reserved

Applied Packaged Terminal Air Conditioner with Catalog Top-Mounted Hydronic Heat

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

Компрессорно-конденсаторные агрегаты. Chiller. AQH DCI 20 to 30. Air Cooled Water Inverter Heat Pump Engineering Data Manual. 20 to 30 kw.

Technical Data ISD 184KY / OSA 184RKTV. Ducted Split System Air Conditioner kw

Figure 1: Schematic of internal heat exchanger vapor-injection cycle

OPA RKTG-P (ECO) Air Cooled Packaged Units - Reverse Cycle - R410A Installation & Maintenance

HIGH TEMPERATURE AIR SOURCE HEAT PUMP WATER HEATER

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

WAHL A Product Specifications

ROOFTOP PACKAGED AIR CONDITIONERS

TEST REPORT #14. System Drop-In Test of Refrigerant Blend ARM-42a in an Air-Cooled Screw Chiller

PLC / HMI Modbus (Slave) Addressing

GUIDE SPECIFICATIONS AQUARIUS ii

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

Installation Manual BCS2000/3000

Product Data. Features/Benefits. 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes. 2to4NominalTons

Technical data. Danfoss DHP-H. Extra and hotter hot water. Extra large integrated hot water tank. Can reduce heating costs by more than 50 percent.

Digital Inverter 4 series 8 & 10HP

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)

MEPS COMPLIANT. Product Review OPA-RK Series. Ducted Packaged Roof Top Air Conditioners kw 137 kw. Extra Long Life Epoxy Coated Outdoor Coil

designed for air conditioning australian living

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG +

Modular Air Cooled Scroll Chillers

WXC R134a. Nominal Cooling Capacity from 224 to 692kW

Technical Data VPA 120, 160. Ducted Vertical Packaged Air Conditioner/Heat Pump kw 16.1 kw. Wide Ambient Capabilities

Brise speed speed control 2. BRIC ceiling model 3. BRIW wall model 4. BRBW wall build-in model 5. grille from ABS 6.

CAUTION. All safety information must be followed as provided in Service Manual RS ! WARNING

Call us today! (800)

Call us today! (800)

Transcription:

SPCIFICTIOS Model HWP 255RKT Item o. (Standard / Opposite Hand) 509-255-001 / 509-255-011 Cooling capacity (net) to S/ZS 3823 T1 24.7 kw Heating capacity H1 23.0 kw lectrical input - cooling 5.8 kw lectrical input - heating 5.4 kw R / R (cooling) 4.29 / 4.28 COP / COP (heating) 4.31 / 4.30 Unit Controller Refrigerant R410 Refrigerant charge 3.4 kg Compressor type scroll connections 1" male SP ominal WT on cooling 30 C ominal WT on heating 21 C ominal Flow @ WT LWT = 5k 1.53 l/s ntering system pressure drop @ nominal flow 48 kpa (7 psi) Min. water temp. Heat cycle at nominal flow 10 C Min. water temp. Cool cycle at nominal flow 15 C Min. water temp. Cool cycle with water flow control valve 5 C Max. WT Heat cycle at nominal flow 30 C Max. WT Cool cycle at nominal flow 50 C Min. water flow @ nominal WT 0.42 l/s Max. water pressure excluding hoses 3200 kpa (464 psi) Power supply 3 ph. 40 ac 50Hz Compressor run amps at rating cond. 8.5 /ph. Indoor fan motor size 750 W Indoor fan motor (1ph.) - full load 6.5 Control circuit breaker (internal) 10 Running amps (total system) 13.5 / 8 / 8 Max. running amps (total system) 18.5 / 13 / 13 et weight 190 kg ccessories: Spring mounts supplied hoses 800mm long, rated 2070 kpa (300 psi) 1" female SP, supplied Replacement filter U2 rated 119-000-104 1398x405x13 Condensate lift-pump 507-003-010 Optional: ST-3 Room temperature controller 201-000-146 TZT-100 Room temperature controller 201-000-350 Refer to temperzone for other options, eg remote sensors 17013

IMSIOS (mm) PROJCTIO HWP 255RKT Standard ot to Scale 500 MI. CLRC W lectrical ox X POIT LOS (kg) W X Y Z 500 MI. CLRC 39 55 63 33 ote: Fan motor can be accessed from panel above, below or sides; no more than two panels at once. Z 67 Y 79 78 HWP 255RKT Opposite Hand 500 MI. CLRC POIT LOS (kg) W X Y Z 63 39 33 55 ote: Fan motor can be accessed from panel above, below or sides; no more than two panels at once. 500 MI. CLRC W lectrical ox X Z Y 79 67 78 OT Specifications are subject to change without notice due to the manufacturer's ongoing research and development programme.

LCTRICL TL2W1 xternal Protection & Isolation Pump Verification ry Contacts If Pump Verification Option fitted remove this link L1 L2 L3 T1 T2 T3 T4 T5 T6 T7 Flow 1 Flow 2 1 6-6- CC TH3 TH2 CM PRC Condensate Pump Flow Control Valve 2R /O Relay 2 /O Relay 1 FR /O T8 Pump 1 Pump 2 ctive C 7-7- CP LU WHT (LOW) R (M) 1 M R (HIGH) IFM IP switch settings JUMPR settings IP switch On/Off 1,7,9,13,14 On ll Others Off Off RV SCRIPTIO Initial Release C temperzone Ltd 2017 Position Jumper T O OT SCL - SK PPROV PFCC removed from legend 19-04-17... C FR & SR now fitted as standard 3941 25-05-17... ow renamed to HWP 255 19-06-17... Client Wiring Sensors (S) / Transducers (T) ame Type Colour L ischarge Temp S R SL Suction Temp S WHIT IC Indoor Coil S YLLOW LPT Low Pressure T HPT High Pressure T rawn: pprvd:... ate: 04-01-17 SR /O 24VC/VC Optional 0-1 Sensors and Transducer *Refer Table Temp Sensors (Refer to table) 1 1 Modbus slave port for MS (monitoring or control option) FLT UX HI M LO C1 L SL 2 2 Modbus master port for optional T/stat (TZT100/ST-3) HPT LPT M Pressure sensors I OC IC V1 V2 1 2 3 SC O CP4W1 CP2W1 0-1 to Regulating Valve If Condensate Float Switch Option fitted remove this link Condensate Float Switch (ormally closed) Remote On/Off ry Contact C 1- If Remote On/Off option fitted remove this link RV 1- CP CPCITOR CC COTROL CIRCUIT RKR CM PRSSOR MOTOR PRSSOR COTCTOR CP2W COCTOR PLUG 2 WY CP4W COCTOR PLUG 4 WY V LCTROIC XPSIO VLV 2R XV2 RLY OR FR FULT RLY OR Title: rawing o: Rev: 291-002-186 HWP 255RKT Wiring Schematic TH RTH IFM IOOR F MOTOR PRC PHS ROTTIO COTROLLR PHS ROTTIO RLY RV RVRSIG VLV SR STTUS RLY OR T TRMIL LOCK TL2W TRMIL LOCK LIK 2 WY UIT COTROLLR 8 SHT 1 OF 1 XV1 XV2 I#1 I#1 C2 HT CP I#2 I#2 HIGH M LOW C3 C4 L 5 VF VC V (Sanhua) P1 Refer to IP S/W settings isplay SW1 SW2 SW3

003-000-101 06/17 www.temperzone.biz temperzone limited 2017

SPCIFICTIOS Model HWP 255CKT HWP 255CKT Item o. - Standard 509-255-101 509-255-102 Item o. - Opposite Hand 509-255-111 509-255-1 Cooling capacity (net) to S/ZS 3823 T1 24.7 kw Heating capacity - lectric heat n/a.0 kw lectrical input - cooling 5.5 kw lectrical input - heating n/a 13.2 kw R / R (cooling) 4.48 / 4.46 Unit Controller Refrigerant Refrigerant charge Compressor type connections R410 3.0 kg scroll 1" male SP ominal WT on cooling 30 C ominal Flow @ WT LWT = 5k ntering system pressure drop @ nominal flow 1.53 l/s 48 kpa (7 psi) Min. water temp. Cool cycle at nominal flow 15 C Min. water temp. Cool cycle with water flow control valve 5 C Max. WT Cool cycle at nominal flow 50 C Min. water flow @ nominal WT Max. water pressure excluding hoses Power supply Compressor run amps at rating cond. Indoor fan motor size Indoor fan motor (1ph.) - full load Control circuit breaker (internal) 0.42 l/s 3200 kpa (464 psi) 3 ph. 40 ac 50Hz 8 750 W 6.5 10 Running amps (total system) 13 / 8 / 8 23 / 17.5 / 17.5 Max. running amps (total system) 19 / 13 / 13 24 / 17.5 / 17.5 et weight 190 kg 190 kg ccessories: Spring mounts hoses 800mm long, rated 2070kPa (300psi) Replacement filter supplied 1" female SP, supplied 119-000-104 1398x405x13 Condensate lift-pump 507-003-010 Optional: ST-3 Room temperature controller 201-000-146 TZT-100 Room temperature controller 201-000-350 Refer to temperzone for other options, eg remote sensors Tested in accordance with S/ZS 3823 17013

IMSIOS (mm) PROJCTIO HWP 255 CKT/CKT Standard ot to Scale 500 MI. CLRC W lectrical ox X POIT LOS (kg) W X Y Z 500 MI. CLRC 39 55 63 33 ote: Fan motor can be accessed from panel above, below or sides; no more than two panels at once. Z 67 Y 79 78 HWP 255 CKT/CKT Opposite Hand 500 MI. CLRC POIT LOS (kg) W X Y Z 63 39 33 55 ote: Fan motor can be accessed from panel above, below or sides; no more than two panels at once. W lectrical ox X Z Y 79 500 MI. CLRC 78 67 OT Specifications are subject to change without notice due to the manufacturer's ongoing research and development programme.

LCTRICL TL2W1 xternal Protection & Isolation Pump Verification ry Contacts If Pump Verification Option fitted remove this link L1 L2 L3 T1 T2 T3 T4 T5 T6 T7 Flow 1 Flow 2 1 6-6- CC TH3 TH2 CM PRC Condensate Pump Flow Control Valve 2R /O Relay 2 /O Relay 1 FR /O T8 Pump 1 Pump 2 ctive C 7-7- CP LU WHT (LOW) R (M) 1 M R (HIGH) IFM IP switch settings JUMPR settings IP switch On/Off 1,7,9,13,14 On ll Others Off Off RV SCRIPTIO Initial Release C temperzone Ltd 2017 Position Jumper T O OT SCL - SK PPROV PFCC removed from legend 19-04-17... C FR & SR now fitted as standard 3941 25-05-17... ow renamed to HWP 255 19-06-17... Client Wiring Sensors (S) / Transducers (T) ame Type Colour L ischarge Temp S R SL Suction Temp S WHIT IC Indoor Coil S YLLOW LPT Low Pressure T HPT High Pressure T rawn: pprvd:... ate: 09-02-17 SR /O 24VC/VC Optional 0-1 Sensors and Transducer *Refer Table Temp Sensors (Refer to table) 1 1 Modbus slave port for MS (monitoring or control option) FLT UX HI M LO C1 L SL 2 2 Modbus master port for optional T/stat (TZT100/ST-3) HPT LPT M Pressure sensors I OC IC V1 V2 1 2 3 SC O CP4W1 CP2W1 0-1 to Regulating Valve If Condensate Float Switch Option fitted remove this link Condensate Float Switch (ormally closed) Remote On/Off ry Contact C 1- If Remote On/Off option fitted remove this link 1- CP CPCITOR CC COTROL CIRCUIT RKR CM PRSSOR MOTOR PRSSOR COTCTOR CP2W COCTOR PLUG 2 WY CP4W COCTOR PLUG 4 WY V LCTROIC XPSIO VLV 2R XV2 RLY OR FR FULT RLY OR Title: rawing o: Rev: 291-002-209 HWP 255CKT Wiring Schematic TH RTH IFM IOOR F MOTOR PRC PHS ROTTIO COTROLLR PHS ROTTIO RLY SR STTUS RLY OR T TRMIL LOCK TL2W TRMIL LOCK LIK 2 WY UIT COTROLLR 8 SHT 1 OF 1 XV1 XV2 I#1 I#1 C2 HT CP I#2 I#2 HIGH M LOW C3 C4 L 5 VF VC V (Sanhua) P1 Refer to IP S/W settings isplay SW1 SW2 SW3

TH2 TH3 T1 T2 T3 TL2W1 SR V (Sanhua) HC1 HC2 Optional 0-1 T4 L1 T5 Sensors and Transducer *Refer Table 24VC/VC /O H1 H2 H3 L2 T6 L3 VC VF HI M LO C1 5 xternal Protection & Isolation I#2 I#2 I#1 I#1 C2 HT CP Modbus slave port for MS (monitoring or control option) 1 1 UX XV2 XV1 FR PRC CC Refer to IP S/W settings FLT /O Modbus master port for optional T/stat (TZT100/ST-3) 2 2 SW1 SW2 2R Temp Sensors (Refer to table) P1 Condensate Pump L SL isplay /O Relay 2 0-1 to Regulating Valve Pump Verification ry Contacts If Condensate Float Switch Option fitted remove this link V1 V2 I M SW3 Relay 1 OC IC /O Flow Control Valve CM 6- CP4W1 1 2 Pressure sensors HPT LPT 6- T7 Flow 1 Flow 2 Condensate Float Switch (ormally closed) 3 SC C3 LOW M F -0 F -0 G -1 HIGH 1 CP2W1 If Pump Verification Option fitted remove this link Remote On/Off ry Contact O L C4 C 6- If Remote On/Off option fitted remove this link HST C 6-1- T8 Pump 1 Pump 2 t ctive HC2 1- MST t T9 HC1 CP G -4 4-4- WHT (LOW) R (M) LU 1 M R (HIGH) IFM JUMPR settings IP switch settings FR FULT RLY OR TH RTH HST HIGH TMPRTUR SFTY THRMOSTT IFM IOOR F MOTOR PRC PHS ROTTIO COTROLLR PHS ROTTIO RLY SR STTUS RLY OR T TRMIL LOCK TL2W TRMIL LOCK LIK 2 WY UIT COTROLLR 8 CP CPCITOR CC COTROL CIRCUIT RKR CM PRSSOR MOTOR PRSSOR COTCTOR CP2W COCTOR PLUG 2 WY CP4W COCTOR PLUG 4 WY V LCTROIC XPSIO VLV 2R XV2 RLY OR H LCTRIC HT HC LCTRIC HT COTCTOR Sensors (S) / Transducers (T) ame Type Colour M Fast Temp Sensor S LCK L ischarge Temp S R SL Suction Temp S WHIT Position Jumper IP switch On/Off 1,3,4,7,9,13,14 On ll Others Off Off PPROV T C IC Indoor Coil S YLLOW RV SCRIPTIO Initial Release LPT Low Pressure T HPT High Pressure T PFCC removed from legend 19-04-17... C FR & SR now fitted as standard 3941 25-05-17... ow renamed to HWP 255 19-06-17... Title: rawing o: Rev: 291-002-187... ate: 04-01-17 rawn: temperzone Ltd 2017 Client Wiring SHT 1 OF 1 HWP 255CKT Wiring Schematic pprvd: O OT SCL - SK 003-000-100 06/17 www.temperzone.biz temperzone limited 2017