1 SPCIFICTIOS Model HWP 192RKT Item o. (Standard / Opposite Hand) / Cooling capacity (net) to S/ZS 3823 T kw Heating capacity H kw lectrical input - cooling 4.8 kw lectrical input - heating 4.5 kw R / R (cooling) 4.11 / 4.09 COP / COP (heating) 4.17 / 4.15 Unit Controller Refrigerant R410 Refrigerant charge 2.7 kg Compressor type scroll connections 1" male SP ominal WT on cooling 30 C ominal WT on heating 21 C ominal WT LWT = 5k 1.26 l/s ntering system pressure nominal flow 34 kpa (5 psi) Min. water temp. Heat cycle at nominal flow 10 C Min. water temp. Cool cycle at nominal flow 15 C Min. water temp. Cool cycle with water flow control valve 5 C Max. WT Heat cycle at nominal flow 30 C Max. WT Cool cycle at nominal flow 50 C Min. water nominal WT 0.35 l/s Max. water pressure excluding hoses 3200 kpa (464psi) Power supply 3 ph. 40 ac 50Hz Compressor run amps at rating cond. 7 Indoor fan motor size 750 W Indoor fan motor (1ph.) - full load 6.0 Control circuit breaker (internal) 10 Running amps (total system) / 7 / 7 Max. running amps (total system) 16 / 10.8 / 10.8 et weight 177 kg ccessories: Spring mounts supplied hoses 800mm long, rated 300psi 1" female SP, supplied Replacement filter U2 rated x405x13 Condensate lift-pump Optional: ST-3 Room temperature controller TZT-100 Room temperature controller Refer to temperzone for other options, eg remote sensors Tested in accordance with S/ZS
2 IMSIOS (mm) PROJCTIO HWP 192RKT Standard ot to Scale W LCTRICL OX X POIT LOS (kg) W X Y Z ote: Fan motor can be accessed from panel above, below or sides; no more than two panels at once. Z Y HWP 192RKT Opposite Hand POIT LOS (kg) W X Y Z W LCTRICL OX X ote: Fan motor can be accessed from panel above, below or sides; no more than two panels at once. Z Y OT Specifications are subject to change without notice due to the manufacturer's ongoing research and development programme.
3 LCTRICL TL2W1 xternal Protection & Isolation Pump Verification ry Contacts If Pump Verification Option fitted remove this link L1 L2 L3 T1 T2 T3 T4 T5 T6 T7 Flow 1 Flow CC TH3 TH2 CM PRC Condensate Pump Flow Control Valve 2R /O Relay 2 /O /C Relay 1 FR /C /O T8 Pump 1 Pump 2 ctive C 7-7- CP LU WHT (LOW) R (M) 1 M R (HIGH) IFM IP switch settings JUMPR settings IP switch On/Off 1,7,10,13,14 On ll Others Off Off Position Jumper RV SCRIPTIO C T PPROV Initial Release FR & SR now fitted as standard Sensors (S) / Transducers (T) ame Type Colour L ischarge Temp S R SL Suction Temp S WHIT IC Indoor Coil S YLLOW LPT Low Pressure T HPT High Pressure T temperzone Ltd 2015 O OT SCL - SK Client Wiring rawn: pprvd:... ate: SR /C /O 24VC/VC Optional 0-1 Sensors and Transducer *Refer Table Temp Sensors (Refer to table) 1 1 Modbus slave port for MS (monitoring or control option) FLT UX HI M LO C1 L SL 2 2 Modbus master port for optional T/stat (TZT100/ST-3) HPT LPT M Pressure sensors I OC IC V1 V SC O CP4W1 CP2W1 0-1 to Regulating Valve If Condensate Float Switch Option fitted remove this link Condensate Float Switch (ormally closed) Remote On/Off ry Contact C If Remote On/Off option fitted remove this link RV CP CPCITOR CC COTROL CIRCUIT RKR CM PRSSOR MOTOR PRSSOR COTCTOR CP2W COCTOR PLUG 2 WY CP4W COCTOR PLUG 4 WY V LCTROIC XPSIO VLV 2R XV2 RLY OR FR FULT RLY OR TH RTH Title: rawing o: Rev: HWP 172 & 192RKT Wiring Schematic IFM IOOR F MOTOR PRC PHS ROTTIO COTROLLR PFCC POWR FCTOR CORRCTIO CPCITOR PHS ROTTIO RLY RV RVRSIG VLV SR STTUS RLY OR T TRMIL LOCK TL2W TRMIL LOCK LIK 2 WY UIT COTROLLR 8 SHT 1 OF 1 XV1 XV2 I#1 I#1 C2 HT CP I#2 I#2 HIGH M LOW C3 C4 L 5 VF VC V P1 Refer to IP S/W settings isplay SW1 SW2 SW3
4 /17 temperzone limited 2017
5 SPCIFICTIOS Model HWP 192CKT HWP 192CKT Item o. - Standard Item o. - Opposite Hand Cooling capacity (net) to S/ZS 3823 T kw Heating capacity - lectric heat n/a 9.0 kw lectrical input - cooling 4.8 kw lectrical input - heating n/a 10.3 kw R / R (cooling) 4.11 / 4.09 Unit Controller Refrigerant Refrigerant charge Compressor type connections R kg scroll 1" male SP ominal WT on cooling 30 C ominal WT LWT = 5k ntering system pressure nominal flow 1.26 l/s 34 kpa (5 psi) Min. water temp. Cool cycle at nominal flow 15 C Min. water temp. Cool cycle with water flow control valve 5 C Max. WT Cool cycle at nominal flow 50 C Min. water nominal WT Max. water pressure excluding hoses Power supply Compressor run amps at rating cond. Indoor fan motor size Indoor fan motor (1ph.) - full load Control circuit breaker (internal) 0.35 l/s 3200 kpa (464 psi) 3 ph. 40 ac 50Hz W 6 10 Running amps (total system) / 7 / / 13 / 13 Max. running amps (total system) 16 / 10.8 / / 13 / 13 et weight 177 kg 177 kg ccessories: Spring mounts hoses 800mm long, rated 300psi Replacement filter - rated U2/G2 supplied 1" female SP, supplied x405x13 Condensate lift-pump Optional: ST-3 Room temperature controller TZT-100 Room temperature controller Refer to temperzone for other options, eg remote sensors Tested in accordance with S/ZS
6 IMSIOS (mm) PROJCTIO HWP 192 CKT/CKT Standard ot to Scale W LCTRICL OX X POIT LOS (kg) W X Y Z ote: Fan motor can be accessed from panel above, below or sides; no more than two panels at once. Z Y HWP 192 CKT/CKT Opposite Hand POIT LOS (kg) W X Y Z W LCTRICL OX X ote: Fan motor can be accessed from panel above, below or sides; no more than two panels at once. Z Y OT Specifications are subject to change without notice due to the manufacturer's ongoing research and development programme.
7 LCTRICL TL2W1 xternal Protection & Isolation Pump Verification ry Contacts If Pump Verification Option fitted remove this link L1 L2 L3 T1 T2 T3 T4 T5 T6 T7 Flow 1 Flow CC TH3 TH2 CM PRC Condensate Pump Flow Control Valve 2R /O Relay 2 /O /C Relay 1 FR /C /O T8 Pump 1 Pump 2 ctive C 7-7- CP LU WHT (LOW) R (M) 1 M R (HIGH) IFM IP switch settings JUMPR settings IP switch On/Off 1,7,10,13,14 On ll Others Off Off Position Jumper RV SCRIPTIO C T PPROV Initial Release FR & SR now fitted as standard Sensors (S) / Transducers (T) ame Type Colour L ischarge Temp S R SL Suction Temp S WHIT IC Indoor Coil S YLLOW LPT Low Pressure T HPT High Pressure T temperzone Ltd 2017 O OT SCL - SK Client Wiring rawn: pprvd:... ate: SR /C /O 24VC/VC Optional 0-1 Sensors and Transducer *Refer Table Temp Sensors (Refer to table) 1 1 Modbus slave port for MS (monitoring or control option) FLT UX HI M LO C1 L SL 2 2 Modbus master port for optional T/stat (TZT100/ST-3) HPT LPT M Pressure sensors I OC IC V1 V SC O CP4W1 CP2W1 0-1 to Regulating Valve If Condensate Float Switch Option fitted remove this link Condensate Float Switch (ormally closed) Remote On/Off ry Contact C If Remote On/Off option fitted remove this link CP CPCITOR CC COTROL CIRCUIT RKR CM PRSSOR MOTOR PRSSOR COTCTOR CP2W COCTOR PLUG 2 WY CP4W COCTOR PLUG 4 WY V LCTROIC XPSIO VLV 2R XV2 RLY OR FR FULT RLY OR TH RTH IFM IOOR F MOTOR PRC PHS ROTTIO COTROLLR PFCC POWR FCTOR CORRCTIO CPCITOR PHS ROTTIO RLY SR STTUS RLY OR T TRMIL LOCK TL2W TRMIL LOCK LIK 2 WY UIT COTROLLR 8 Title: rawing o: Rev: HWP 172 & 192CKT Wiring Schematic SHT 1 OF 1 XV1 XV2 I#1 I#1 C2 HT CP I#2 I#2 HIGH M LOW C3 C4 L 5 VF VC V P1 Refer to IP S/W settings isplay SW1 SW2 SW3
8 TH2 TH3 T1 T2 T3 TL2W1 SR V HC1 HC2 Optional 0-1 T4 L1 T5 Sensors and Transducer *Refer Table 24VC/VC /C /O H1 H2 H3 L2 T6 L3 VC VF HI M LO C1 5 xternal Protection & Isolation I#2 I#2 I#1 I#1 C2 HT CP Modbus slave port for MS (monitoring or control option) 1 1 UX XV2 XV1 FR PRC CC Refer to IP S/W settings FLT /C /O Modbus master port for optional T/stat (TZT100/ST-3) 2 2 SW1 SW2 2R Temp Sensors (Refer to table) P1 Condensate Pump L SL isplay /O Relay to Regulating Valve Pump Verification ry Contacts If Condensate Float Switch Option fitted remove this link V1 V2 I M SW3 Relay 1 OC IC /O /C Flow Control Valve CM 6- CP4W1 1 2 Pressure sensors HPT LPT 6- T7 Flow 1 Flow 2 Condensate Float Switch (ormally closed) 3 SC C3 F -0 F -0 G -1 LOW M HIGH 1 CP2W1 If Pump Verification Option fitted remove this link Remote On/Off ry Contact O L C4 C 6- If Remote On/Off option fitted remove this link HST C 6- T8 Pump 1 Pump 2 t ctive HC2 MST t T9 HC1 CP G WHT (LOW) R (M) LU 1 M R (HIGH) IFM TH RTH HST HIGH TMPRTUR SFTY THRMOSTT IFM IOOR F MOTOR PRC PHS ROTTIO COTROLLR PFCC POWR FCTOR CORRCTIO CPCITOR PHS ROTTIO RLY SR STTUS RLY OR T TRMIL LOCK TL2W TRMIL LOCK LIK 2 WY UIT COTROLLR 8 CP CPCITOR CC COTROL CIRCUIT RKR CM PRSSOR MOTOR PRSSOR COTCTOR CP2W COCTOR PLUG 2 WY CP4W COCTOR PLUG 4 WY V LCTROIC XPSIO VLV 2R XV2 RLY OR H LCTRIC HT HC LCTRIC HT COTCTOR FR FULT RLY OR JUMPR settings IP switch settings Sensors (S) / Transducers (T) ame Type Colour M Fast Temp Sensor S LCK L ischarge Temp S R SL Suction Temp S WHIT Position Jumper IP switch On/Off 1,3,4,7,10,13,14 On ll Others Off Off IC Indoor Coil S YLLOW LPT Low Pressure T RV SCRIPTIO C T PPROV Initial Release FR & SR now fitted as standard HPT High Pressure T Title: rawing o: Rev: ate: rawn: temperzone Ltd 2015 Client Wiring SHT 1 OF 1 HWP 172 & 192CKT Wiring Schematic pprvd: O OT SCL - SK /17 temperzone limited 2017
Item No. (Standard / Opposite Hand) /
SPCIFICTIOS Model HWP 255RKT Item o. (Standard / Opposite Hand) 509-255-001 / 509-255-011 Cooling capacity (net) to S/ZS 3823 T1 24.7 kw Heating capacity H1 23.0 kw lectrical input - cooling 5.8 kw lectrical
More informationItem No. (Standard/Opposite Hand) /
SPCIICATIOS Model HWP 118RKTY Item o. (Standard/Opposite Hand) 510-118-001 / 510-118-011 Cooling capacity (net) to AS/ZS 3823 T1 11.9 kw Heating capacity H1 11.6 kw lectrical input - cooling 2.9 kw lectrical
More informationItem No. (Standard/Opposite Hand) /
SPECIFICATIONS Model HWP 59RKS Item No. (Standard/Opposite Hand) 509-059-001 / 509-059-011 Cooling capacity (net) to AS/NZS 3823 T1 5.7 kw Heating capacity H1 5.4 kw Electrical input - cooling 1.6 kw Electrical
More informationUnit Controller (UC8) Quick Reference Operation and Fault Diagnosis
Unit Controller (UC8) Quick Reference Operation and Fault Diagnosis (To be read in conjunction with labels TZ243 (Air-to-Air) & TZ245 (Water-to-Air) Date: 20 October 2015 Issue: 1 Index 1. Introduction...
More informationDUCTED WATER COOLED PACKAGED AIR CONDITIONERS HWP models (c/w UC8) Installation & Maintenance
DUCTED WATER COOLED PACKAGED AIR CONDITIONERS HWP models (c/w ) Installation & Maintenance 1. GENERAL 1.1 Introduction Follow these instructions to ensure the optimum performance, reliability and durability.
More informationS D HWP 77, 96. Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance. Fig. 1 Nomenclature. Fig.
HWP 77, 96 Ducted Water Cooled R410A Packaged Air Conditioner Installation & Maintenance Fig. 1 Nomenclature Nomenclature e.g. H W P 7 7 C K Series Size Type S D GENERAL HWP - A general designation which
More informationOPA RKTG-P (ECO) c/w UC8 Air Cooled Packaged Units - Reverse Cycle - R410A Installation & Maintenance
OPA 465 960 RKTG-P (ECO) c/w UC8 Air Cooled Packaged Units - Reverse Cycle - R410A Installation & Maintenance CONTENTS Page 1. General... 1 2. Installation...1 3. Refrigeration System... 2 4. Wiring...
More informationWater Cooled Units HWP 370, 445. Cooling Capacity 36.6kW kW. Heating Capacity 34.9kW kW
Water Cooled Units Technical Data HWP 370, 445 Cooling Capacity 36.6kW - 44.5kW Heating Capacity 34.9kW - 42.2kW Contents HWP 370, 445 General 3 Applications 4 Introduction 4 Features 5 Refrigerant 5 Efficient
More informationOPTIONAL SPRING MTG HANGING CENTRES WATER CONN'S: TWO BSP MALE. 19 mm (3/4") ELECTRICAL CONDUIT HOLES ACCESS PANEL OUT (WATER) IN 485 MOUNTING
HWP 117 225 Ducted Water Cooled R410A Packaged Air Conditioner Dimensions (mm) Fig. 1 HWP 117 60 1210 SPRING MOUNTING CENTRES 690 (HEIGHT = 370) FILTER BOX PROJECTION Net Weight 105 kg Installation & Maintenance
More informationREVERSE CYCLE DUCTED SPLIT SYSTEMS (ISDL/OSA c/w UC8/IUC) Installation & Maintenance
REVERSE CYCLE DUCTED SPLIT SYSTEMS (ISDL/OSA c/w UC8/IUC) Installation & Maintenance 1.GENERAL Temperzone ISDL Indoor units are designed to be coupled to the matching OSA outdoor unit. Follow these instructions
More informationS Y D. HWP 35, 47, 58 (c/w EC Motor & UC7 Controller) Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance
HWP 35, 47, 58 (c/w EC Motor & UC7 Controller) Ducted Water Cooled R410A Packaged Air Conditioner Installation & Maintenance Fig. 1 Nomenclature Nomenclature e.g. H W P 3 5 C K Series Size Type S Y D GENERAL
More informationWater Cooled Air Conditioners Applications Manual
s Manual HWP-K UC8 Series Contents HWP-K UC8 SERIES Location & Acccess 3 Noise Considerations 4 Water Treatment for Systems using 5 Cooling Towers Water Loop & Unit Control 6 Selection of Balancing Valves
More informationUP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM
EFFICIENT UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase REFRIGERATION CIRCUIT S 2- stage scroll compressors
More informationR 407 C. > in industrial application. Always very much appreciated for special installations these units shown their powers :
SINGLEPACKAGE CONSOLE UNITS, MONOSPLIT, AIR CONDENSING UNITS APPLICATIONS COMMERCIAL SECTOR CONSOLE UNITS AIR CONDENSING UNITS Always very much appreciated for special installations these units shown their
More informationUNIT CONTROLLER 8 (UC8) Troubleshooting guide
UNIT CONTROLLER 8 (UC8) Troubleshooting guide Date: 27 July 2015 Issue: 2 Page 1 of 18 Contents 1. Cautions... 3 2. Recommended service tool set... 3 3. Recommended set of spare parts... 3 4. Items to
More informationRefrigerant Cycle. Performance Data 1) Electric. Acoustic Pressure Level. Compressor. Connections, Dimensions
TECHNICAL DATA SHEET HP08L-M-WEB Performance Data 1) A-7W35 A2W35 A10W35 A2W50 Heating capacity 8,67 kw 11,14 kw 14,91 kw 9,87 kw Cooling capacity 6,16 kw 8,58 kw 12,33 kw 6,43 kw Input 2,51 kw 2,56 kw
More informationTechnical Data Ducted Three Phase Split System Air Conditioner
ENERGY EFFICIENT ISD / OSA 2 Technical Data Ducted Three Phase Split System Air Conditioner EXTRA LONG LIFE EPOXY COATED OUTDOOR COIL Nominal Cooling Capacity 26.5 kw (Total) JUNE 4 ISD / OSA 2 DUCTED
More informationTechnical Data ISU Series. Underceiling/Console Split System Air Conditioners kw 15 kw
Underceiling/Console Split System Air Conditioners Technical Data ISU Series Featuring SAT- Controller & Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 13. kw 15 kw NOVEMBER 0 ISU SERIES
More informationENGINEERING SPECIFICATIONS
ENGINEERING SPECIFICATIONS RH-24-HAC-P-1L-C-SDE*F Horizontal Single Stage R410a Model Size 24 Reversing (Heating AND Cooling) 208/230-1-60VAC Liquid to Air Geothermal Heat Pumps Maritime Geothermal Ltd.
More informationENGINEERING SPECIFICATIONS
ENGINEERING SPECIFICATIONS RH-12-HAC-P-1L-C-SDE*F Horizontal Single Stage R410a Model Size 12 Reversing (Heating AND Cooling) 208/230-1-60VAC Liquid to Air Geothermal Heat Pumps Maritime Geothermal Ltd.
More informationTechnical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil
Ducted Three Phase Packaged Air Conditioner Technical Data, 0, 180 Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 10.0 kw 18.5 kw JUNE 5 , 0, 180 DUCTED PACKAGED ROOF TOP AIR CONDITIONERS
More informationTechnical Data OPA RKTBG-P. Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw
Ducted Three Phase Packaged Air Conditioners Technical Data 96 RKTBG-P Plug Fan with High Efficiency EC Motor and High External Static Economiser Option TZT Controller & Digital Scroll Compressor for close
More informationSLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual
u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications
More informationLSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES
LS ir cooled water chillers with axial fans + LS The LS water chiller range has been designed for small and medium residential and commercial applications. They are suitable for generating chilled water
More informationN4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz
ENVIRONMENTALLY SOUND REFRIGERANT N4H4 Performance Series Product Specifications 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION
More informationHT V2 HT Split
Scroll compressor Refrigerant R07C Aqu@Scop HT V Aqu@Scop HT Split High Temperature Air-to-Water Heat Pumps Models -, -7 and 8-9.0 to 7.9kW Aqu@Scop HT V / Aqu@Scop HT Split Installation examples - Single
More informationCompact, Self-Contained unit that offer low installation cost plus dependable performance.
0 Compact, Self-Contained unit that offer low installation cost plus dependable performance. From carrier s excellence in engineering come a new, compact of single package horizontal and vertical water
More informationR4H4. Product Specifications
R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Scroll compressors on
More informationCooling Capacity 3.5kW kW. Heating Capacity 4.4kW kW. Air Conditioning. Giving you complete control
Cooling Capacity 3.5kW - 101.6kW Heating Capacity 4.4kW - 98.6kW Water-Cooled Air Conditioning Giving you complete control More than just another air conditioning company. We re dedicated to pioneering
More informationTechnical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging
Ducted Three Phase Packaged Air Conditioners Technical Data, 340, 370 Twin System Enables Staging Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 29.5 kw 34.0 kw 39.1 kw OCTOBER 2013
More informationTECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS
TC SERIES OPTIONS TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15,, 5 AIR COOLED PACKAGED WATER CHILLERS CONTENTS EQUIPMENT AND COMPONENT DETAILS PERFORMANCE AND TECHNICAL DATA SCHEMATIC FLOW & SYSTEM
More informationR4H4. Product Specifications
ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION
More informationTECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA
TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA ARGO 245C / 3SC Cooling only model ARGO 235H / 3HP Heat pump model 0.8180.405.2 09/2006 Table of contents Page A SPECIFICATIONS 1) Unit specifications 3
More informationDYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers
High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 35 to 700 kw 410A Cooling Operation DYNACIAT - DYNACIAT POWER
More informationAQUASNAP JUNIOR 30RHV
High-Efficiency Air-To-Water Heat Pumps Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. AQUASNAP JUNIOR 3RHV 6-11
More informationApplication and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A ), 120/208/240/1/60, R404A, LT/MT APPS
Application and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A900-22007), 120/208/240/1/60, R404A, LT/MT APPS Introduction The superheat controller is designed
More informationCATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42
SELF CONTAINED HORIZONTAL UNITS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER ) HEAT PUMP. WCHBZ COOLING ONLY. WCHZ SERIES: WCHBZ - Heat Pump MODELS: 201, 251, 271, 351, 401, 501 COOLING
More informationEC Motor Fan Coil Units. IMDL-Y Series l/s
C Motor Fan Coil Units IMDL-Y Series 00 700 l/s Temperzone s Fan Coil History Company Profile Temperzone Limited is a leading manufacturer and distributor of quality air conditioning and ventilation products
More informationEC Motor Fan Coil Units. IMDL-Y Series l/s
C Motor Fan Coil Units IMD-Y Series 7 l/s IMD-Y Fan Coil Units Company Profile Temperzone imited is a leading manufacturer and distributor of quality air conditioning and ventilation products throughout
More informationGUIDE SPECIFICATIONS AQUARIUS ii
Catalog (AP Technical Data Sheet) GUIDE SPECIFICATIONS AQUARIUS ii AP Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Heat Pump, Ground Water
More information... RTU. Packaged Air to Air Heat Pump...
... RU Packaged ir to ir Heat Pump... RU... Packaged ir to ir Heat Pump... Reznor's RU range is composed of air to air heat pumps in packaged rooftop configurations, with various heat recovery options
More informationRefrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA
Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA 99336 www.jmcvr.com 1-509-586-9893 Table of Contents TABLE OF FIGURES...1 OVERVIEW OF THE HRC CAPABILITIES...2 INSTALLATION AND
More informationRBR Relay Boxes. Installation Manual. Industrial & Commercial Heating Systems. Doc Ref: M406 Issue 1.
Doc Ref: M0 Issue. Mar 0 RBR Relay Boxes Industrial & Commercial Heating Systems Installation Manual www.powmatic.co.uk + (0) 0 info@powrmatic.co.uk Certificate of Guarantee Dear Customer This is to certify
More informationAir Cooled Scroll Chiller / Heat Pump
Air Cooled Scroll Chiller / Heat Pump SRA 145 Nominal Capacity 67.5 to 1080 kw Refrigerant: R407C and R134a Contents Features 1 MV7 Control 3 Physical Data R407c 5 Physical Data R134a 6 Unit Performance
More informationE1 Electrical Fundamentals. # 4 - Symbols and Wiring Diagrams
E1 Electrical Fundamentals # 4 - Symbols and Wiring Diagrams Loads Electrical Loads onsume electricity Do work Examples: Motors Solenoids Heaters Lights 2005 Refrigeration Training Services - E1#4 Symbols
More informationSINGLE-PACKAGE ROOFTOP HEAT PUMP UNITS INDEX. VOLTAGE (3 Ph, 60 Hz) ACCESSORIES
wiring diagrams SINGLE-PACKAGE ROOFTOP HEAT PUMP UNITS Cancels: New 542J Sizes 150, 180 12-1/2 and 15 Tons WD 542J.150.1 7/15/96 UNIT 542J 150 180 LABEL DIAGRAM TYPE Component Arrangement Schematic Component
More informationDucted Split System Air Conditioners Technical Data
Technical Data ISD 294, ISD 324 Cooling Capacity 27.9kW - 34kW Heating Capacity 28.2kW -32.2kW Contents ISD 294, 324 KYX SERIES General 3 Applications 4 Air Flow Selection 4 Features 4 Refrigerant R410A
More informationDucted Split System Air Conditioners Technical Data
Technical Data ISDL 66, ISDL 87, ISDL 116 Cooling Capacity 6.7kW - 11.2kW Heating Capacity 6.2kW - 11.1kW Contents ISDL 66 116 KYX SERIES 3 General 3 Applications 4 Air Flow Selection 4 Features 4 Refrigerant
More informationSelf-Contained & Split System Reverse Cycle Air Conditioners Models
Self-Contained & Split System Reverse Cycle Air Conditioners s 05-07-10-12-16-18-24 General Description Marvair's water source self-contained and split system reverse cycle air conditioners are designed
More informationRSMV Technical Guide
RSMV Technical Guide TABLE OF CONTENTS OVERVIEW... 4 Features and Applications... 4 Module Dimensions... 5 INSTALLATION & WIRING... 6 Input Wiring... 6 Suction Pressure Sensor...6 Head Pressure Sensor...6
More informationCommercial High-Efficiency Condensing Units
FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON
More informationWDH WDH. Ground source heat pumps OTHER VERSIONS ACCESSORIES
Ground source heat pumps +60 C C.O.P. 5,1 heat pumps are particularly suitable for applications that utilise ground source probes.these units have been designed for use with radiant floor heating systems
More informationDANFOSS OPTYMA PLUS INVERTER UNITS
Optyma Plus Inverter Condensing Units Danfoss Optyma Plus Inverter Units are designed with the unique benefits of stepless inverter scroll technology resulting in a 20-30% higher energy efficiency in a
More informationEKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata
EKS/HE Refrigerant R410A GWP=2.088 Scroll Compressor Shell & Tube exchanger Axial fan Brazed plate heat exchanger MultiScroll Air-cooled liquid chillers High efficiency Solution B - Base I - Integrata
More informationN4H4. Product Specifications
14 SEER HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208/230 Volt 1- phase, 208/230 Volt 3- phase, 460 Volt 3- phase; 60 Hz REFRIGERATION CIRCUIT S Scroll compressors
More informationGeneral Description. Operation
ECUA12ACA & ECUA18ACA SlimPac (1 & 1.5 Ton) Environmental Control Units General Description The Industrial Climate Engineering SlimPac line of Environmental Control Units (ECU) are designed for the telecommunication
More information2009 Panasonic Marketing Europe GmbH / All rights reserved
quarea 2W heat pump PNSONIC PRODUCT OFFER usiness development basic points : To have always the best efficiency of the industry To offer always the easy to install / easy to use / easy to maintain Energy
More informationTechnical data DHP-R. A brine-to-water building heat pump in power outputs
brine-to-water building heat pump in power outputs from to 42 kw. illed with R47 (6 ) or 134a (7 ) refrigerant dvanced control with integrated web monitoring Main components...2 Space requirements...3
More informationNH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT
ENVIRONMENTALLY SOUND REFRIGERANT NH4H4 Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS, 208/230
More informationTechnical Data ISD 184KY / OSA 184RKTV. Ducted Split System Air Conditioner kw
Ducted Split System Air Conditioner Technical Data ISD 184KY / OSA 184RKTV SEPARABLE INDOOR UNIT OPTION Optional SAT Controller High Efficiency EC Motor Extra Long Life Epoxy Coated Outdoor Coil Nominal
More informationGTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts
GTIP60 ISO GT Series, Inch Pounds 60 Hz GT010070 (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts Rev: 903 Rev 1 Revisions: 31103 Changed HZ dwg to field convertible 5902 changed Unit
More informationFigure 1: Schematic of internal heat exchanger vapor-injection cycle
Vapor-injection technique Development Guideline 1. Introduction This guideline shows the advantage and characteristics of Mitsubishi vapor injected-scroll compressor. The vapor injected-scroll compressor
More informationOPA RKTG-P (ECO) Air Cooled Packaged Units - Reverse Cycle - R410A Installation & Maintenance
OPA 465 960 RKTG-P (ECO) Air Cooled Packaged Units - Reverse Cycle - R410A Installation & Maintenance 1. GENERAL Temperzone OPA Outdoor Air Cooled Packaged units. Follow these instructions to ensure the
More informationTechnical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler
Technical Development Program COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Introduction System
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02
More informationWAHL A Product Specifications
ENVIRONMENTALLY SOUND REFRIGERANT FAN COILS Number Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products,
More informationROOFTOP PACKAGED AIR CONDITIONERS
ROOFTOP PACKAGED AIR CONDITIONERS Rooftop Packaged Air Conditioners Hitachi has long been a world leader in the design and manufacture of quality air conditioning systems. With models ranging from room
More informationTEST REPORT #14. System Drop-In Test of Refrigerant Blend ARM-42a in an Air-Cooled Screw Chiller
Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Low-GWP Alternative Refrigerants Evaluation Program (Low-GWP AREP) TEST REPORT #14 System Drop-In Test of Refrigerant Blend ARM-42a in an Air-Cooled
More informationPLC / HMI Modbus (Slave) Addressing
Made in the USA PLC / HMI Modbus (Slave) Addressing Legacy - HMI touch screen with built in Legacy - Pentra PLC with Expandable I/O Legacy Chiller Systems, Inc. General Information IMPORTANT READ BEFORE
More informationTechnical Manual. Multi Split Trio Quattro DCI REFRIGERANT R410A HEAT PUMP
Technical Manual Multi Split Trio Quattro DCI Indoor Units WNG 9 DCI INV WNG 12 DCI INV WNG 18 DCI INV ECF 9 DCI INV ECF 12 DCI INV ECF 18 DCI INV PXD 9 DCI INV PXD 12 DCI INV PXD 18 DCI INV LS 35 DCI
More information30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw
Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The
More informationGUIDE SPECIFICATIONS AQUARIUS ii
Catalog (AP Technical Data Sheet) GUIDE SPECIFICATIONS AQUARIUS ii AP Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Pump, Ground Water Pump
More informationi-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:
ABOUT THE i-chiller RANGE The fully packaged, EcoDesign compliant, air-cooled i-chiller range is designed specifically for reliable and efficient process cooling. The unique evaporator is immersed within
More informationDuct Free Systems Product Data Digest ¾ to 5 Nominal Tons
Duct Free Systems Product Data Digest ¾ to 5 Nominal Tons Console Console Condenser & Mulit-Zone Satellite HDC, HDL, HDS & QR Condensers High Wall AN/BK Condensers Under Ceiling Cassette Copyright 2001
More informationInstallation Manual BCS2000/3000
Installation Manual BCS2000/3000 Supplies Needed for Installation 1. 3/8 and 5/8 copper tubing. 2. 1/4 copper water supply 3. 1/4 condensate vinyl drain tube/tube clamps 4. Provide 120v 15A circuit for
More informationGENERAL NOTES SYMBOLS LEGEND SALES PERSON MASON LASTER PROJECT MANAGER REVISIONS DALLAS, TX ALDI #000 MAIN STREET NEW R1.
GENERAL NOTES R1.0 STORE DESIGN CONDITIONS PAGE: 1 ATLANTA REFRIGERATION ATLANTA REFRIGERATION DATE: 2/10/2015 COD/Buyout Selection PROTOCOL UNIT LEGEND PROTOCOL UNIT LEGEND AMBIENT TEMP: 105 BY: GB STORE:
More informationSELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)
SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER) SERIES: WCHZ MODELS: 201, 251, 271, 351, 401, 501, 701, 721, 751 COOLING CAPACITIES OF: 6,4
More informationMEPS COMPLIANT. Product Review OPA-RK Series. Ducted Packaged Roof Top Air Conditioners kw 137 kw. Extra Long Life Epoxy Coated Outdoor Coil
Ducted Packaged Roof Top Air Conditioners Product Review OPA-RK Series Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 10.6 kw 137 kw MEPS COMPLIANT INVERTER MODEL MODELS MARCH 2014
More informationTechnical data. Danfoss DHP-H. Extra and hotter hot water. Extra large integrated hot water tank. Can reduce heating costs by more than 50 percent.
anfoss HP-H xtra and hotter hot water. xtra large integrated hot water tank. an reduce heating costs by more than 50 percent. Main parts.......................................................................
More informationdesigned for air conditioning australian living
designed for air conditioning australian living ActronAir is Australian made for Australian conditions There s nowhere else in the world that s quite like Australia, and it takes an Australian air conditioning
More informationInstallation, Start-Up and Service Instructions
Installation, Start-Up and Service Instructions GEMINI 38ARZ007-012, 38ARS008-012 38ARD012-024, 38AKS014-024 Air-Cooled Condensing Units 50/60 Hz CONTENTS Page SAFETY CONSIDERATIONS...1 INSTALLATION...
More information50VZ (40PZ/38VZ) Vertical Air-Cooled Split-System Cooling Units. Nominal cooling capacity kw
Vertical Air-Cooled Split-System Cooling Units Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. 50VZ (40PZ/38VZ)
More informationCZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES
High efficiency air to water heat pumps with E.V.I. compressors -15 C +63 C E.V.I. The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems or
More informationTechnical Data VPA 120, 160. Ducted Vertical Packaged Air Conditioner/Heat Pump kw 16.1 kw. Wide Ambient Capabilities
Ducted Vertical Packaged Air Conditioner/Heat Pump Technical Data, 1 Wide Ambient Capabilities Variable Capacity 2kW 12/16kW High Efficiency EC Plug Fan Versatile Configuration Including Controller & Digital
More informationRTHE Series R Helical Rotary Liquid Chiller Tons 60Hz
Features Product and Benefits Catalog RTHE Series R Helical Rotary Liquid Chiller 75-255 Tons 60Hz January 2015 RTHE-PRC002-EN Introduction To meet a wide range of applications in the 75~255 ton water-cooled
More informationModular Air Cooled Scroll Chillers
Modular Air Cooled Scroll Chillers 65 80 130 Find out more at www.greeonline.com 160 249 High Efficiency Shell and Tube Heat Exchanger The Gree D Series Chillers utilise high efficiency shell and tube
More informationWXC R134a. Nominal Cooling Capacity from 224 to 692kW
WXC R134a Nominal Cooling Capacity from 224 to 692kW FEATURES AND BENEFITS Range of 12 models. Higher capacity and higher EER from the same compressor. High EER, low sound power level and high reliability.
More informationCAUTION. All safety information must be followed as provided in Service Manual RS ! WARNING
Amana Technical Information³Refrigerator P1303511W Due to a possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this refrigerator. Refer
More informationКомпрессорно-конденсаторные агрегаты. Chiller. AQH DCI 20 to 30. Air Cooled Water Inverter Heat Pump Engineering Data Manual. 20 to 30 kw.
1 Компрессорно-конденсаторные агрегаты Chiller AQH DCI 20 to 30 Air Cooled Water Inverter Heat ump Engineering Data Manual 20 to 30 kw 20 to 30 kw Specifications 3 AQH DCI Finned coil optimized in ing
More informationProduct Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons
0TJ06-03S Side Discharge Single-Package Rooftop Units 0/ Hz to 30 Nominal Tons Product Data The 0TJ-S series is a special side discharge version packaged unit with capacities of -30 Tons. This unit can
More informationApplied Packaged Terminal Air Conditioner with Catalog Top-Mounted Hydronic Heat
Applied Packaged Terminal Air Conditioner with Catalog 1355-9 Top-Mounted Hydronic Heat 16" 42" Model PDAN Unit Sizes 007 017 R-410A Refrigerant Engineered for flexibility and performance Unit Features
More informationCall us today! (800)
500 TON AIR-COOLED CHILLER PA-ACCTR-500 Call us today! (800)341-4297 The 500-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,
More informationCall us today! (800)
PA-ACCTR-200 Call us today! (800)341-4297 The 200-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable, efficient and quiet chiller
More informationSplit inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45
Plug & Heat heat pump Quick and easy to install For new homes or boiler backup operation 50 HFC R410A CERTIFIED BY CERTITA Heating capacity: 5.5 to 22 kw option CERTIFIED BY CERTITA 30/35-40/45 USE The
More informationVariCool VAV Engineering Guide
Engineering Guide Effective September 2017 Water-Cooled and Chilled Water, Variable Air Volume Contents Product Features... 3 UNIT FEATURES... 3 Product Features... 4 Marvel Plus Microprocessor Control
More informationFALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)
FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz
More informationWATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ
WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ SERIES: EWCBZ - Heat pump MODELS: 70, 80, 00, 0, 60, 00, 40, 00, 50 COOLING CAPACITIES from 5,9 kw to 78,5
More informationRSMSD Technical Guide
RSMSD Technical Guide www.aaon.com AAON/WattMaster Controls Inc. 8500 NW River Park Drive Parkville, MO 64152 Toll Free Phone: 866-918-1100 PH: (816) 505-1100 FAX: (816) 505-1101 E-mail: mail@wattmaster.com
More informationModels: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems
Models: ACC 75D/DR ACC 100D/DR ACC - D2-2007 (Draft) Ceiling Concealed Split Systems CONTENTS 1. NOMENECLATURE... 2 2. FEATURES... 4 3. PRODUCT LINE UP... 5 4. SPECIFICATIONS... 8 5. OPERATING RANGE...
More information