R A D I O N I C S. READYKEY K2015A Alarm Event Manager. Installation Data Sheet. Description

Similar documents
Flair 500 Series Annunciators

Independent Zone Control (I.Z.C.)

LDM Series Lamp Driver Modules For Graphic Annunciation and Control

21-light Remote Annunciator. Owner s Manual

UNC100 Integra Manual

ANNUNCIATOR FIXED MODULE

SP-1000X. Panic Device Power Controller Installation Guide. Rev

KT-100 Door Controller

Duct smoke housings, 4-wire D341/D341P and D342/D342P

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

SCR100 User Manual. Version:1.1 Date:Dec 2009

LifeAlarm Fire Alarm Controls

Fire Control/Communicator

DS7465i. Installation Instructions. Input/Output Module

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector

Duct smoke housing, 2-wire D340/D340P

Interface Modules for SENTRI

Installation Guide for models:

Oxygen (O2) Single-Point Gas Detection System

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

Interface and EOL Modules 8

Product Data Sheet. Remote Terminals. Features:

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

Notification Appliance Circuit Module

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

Carbon Monoxide Transmitter

Remote Chexit Module (RCM) System. General Information

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Macurco DVP-120 / DVP-120M Detection and Ventilation Control Panel User Instructions

DE5300 Delayed Egress System. General Information

Ethernet General Purpose

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

General Purpose IO Technical Manual

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

NetworX NX-548E Receiver Installation Instructions

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

HRX Technical Manual. Version 1.2

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

D8125MUX. Operation and Installation Guide. Multiplex Bus Interface

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

FIRERAY 5000 range USER GUIDE

D9210B Access Control Interface Module Operation and Installation Manual

B-40/B-41 Modulating Temperature Controller

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

SINGLE CHANNEL SYSTEM TWO CHANNEL SYSTEM

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

D326A/D334A/D339A. Installation Instructions. Point Contact Modules

APPLICATION NOTES. Stone Technologies Corporation Westrock Dr. #4 Austin, Texas OUT + + IN - + IN - + IN - + IN -

DS7400Xi Addressable Control/ Communicator

Installation Guide for models:

D2071A. Operation & Installation Guide Fire Alarm Control Panel

2200 and 2200L ALARM CONTROL SYSTEMS

4100U City and Relay Cards Installation Instructions

General Routing Interface

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

Installation, Operating and Maintenance Manual

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Duct and Rough Service Carbon Monoxide Sensor

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

Easy Series ICP-EZM2. System Reference Guide

ECO N DATE DESCRIPTION OF CHANGE CHG

Networked Access Control Panel. Installation Guide

Public Safety DAS Annunciator Panel

QA16 Addressable System

Multiple Input and Output Modules

Easikey 1000 / 1000 Plus

Touchpoint 4. The Touchpoint 4 controller provides protection of personnel and plant from flammable, toxic and Oxygen gas hazards

INSTALLATION MANUAL & PROGRAM RECORD SHEET

Addressable NAC Output Module D327A

Model 17A00 Expansion Enclosure

Booster Power Supply Manual

SIGA-CC1 Single Input Signal Module Installation Sheet

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

FIRE STROBE 2000 INSTALLATION INSTRUCTIONS

TrueAlarm Analog Sensing

Product Manual SZ1145

Analog Room Pressure Monitor RPC Series

MBUV-100D, MBUVS-100D MBIR-100D, MBFR-100D DIN RAIL MOUNT FLAMEWORX MODULES

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

AU MX Digital Loop Card Installation Instructions

HRX3000. Technical Manual

These instructions detail procedures to follow in order to avoid damage to equipment.

TruPortal Wireless Locks Quick Reference

Control Relay Modules

ELT-KLED EliteSuite LED Keypad Installation Manual

Model 4880 Status Output Display Module Manual

Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions

Remote NAC Power Supply D7038

AA11 - A SMART SHOCK SENSOR

D2412 Control / Communicator Installation Manual

Transcription:

R A D I O N I C S READYKEY K2015A Alarm Event Manager Installation Data Sheet READER CONTROLLER INPUTS INPUTS RLY 8 RLY 7 RLY 6 RLY 5 RLY 4 RLY 3 RLY 2 RLY 1 8 Supervised Inputs (Normally Open or Normally Closed) 8 Latched Relay Outputs (Readykey for Windows systems only) 8 Relay Outputs when used with Readykey for Windows Steel Case with Tamper Protection Description Diagnostic Display The K2015A Alarm Event Manager is an optional device that can be connected in between a Readykey Door Controller and a Readykey Reader. It can monitor up to 8 inputs and provides 8 relay outputs. The response to the inputs and the control of the relay outputs is determined by the type of door controller and the type of administration system. To take full advantage of all its features, the device should be connected to a K2100 or K1100 door controller administered by Readykey for Windows. When not being administered by Readykey for Windows, the K2015A Alarm Event Manager behaves in the same way as the Readykey K2015 Alarm Module, for which it is a complete replacement. Inputs All eight inputs are fully supervised. By using an end of line resistor and a resistor across the detector contacts, four different input states can be detected. These states are Normal, Active, Open (Tamper) and Short (Trouble). A set of switches determines whether an input is Normally Open or Normally Closed. K2015A Installation Data Sheet 17137 v1.0 74-07213-000-A 4/94 Page 1 1994 Radionics, Inc

Specification Compatibility Specification The K2015A can be used on any of the following Readykey controllers: K6100-16 and 32 Office Admin. Kit K6100-SS and K6100-MS K2100 multi-function 4 door controller K1100 multi-function 2 door controller K2000-AM master 4 door controller K2000 -N slave 4 door controller When the access control system is administered by any of the methods described below, then the K2015A is programmed, and responds, in exactly the same way as a Readykey K2015 Alarm Module. K2000-AM Front Panel K2100 Front Panel K1100 Front Panel K6000-AM Office Administration Kit K6000, K6000-MS Enclosure Environmental Power Supply Cable Inputs Material Dimensions Temperature Humidity 1.2mm Epoxy coated mild steel 184mm x 148mm x 38mm, 7.2in x 5.8in x 1.8in -10ºC to +55ºC 0% to 90% RH (non-condensing) Power for the K2015A is provided by the door controller reader channel. Voltage 10.2-18 VDC Current 30mA maximum Type 6 conductor, multi-stranded, unshielded cable *Distance/Gauge Up to 250m: 0.22mm² Up to 750ft: 24 AWG Up to 500m: 0.50mm² Up to 1500ft: 20 AWG Up to 1000m: 1.00mm² Up to 3000ft: 18 AWG * Total Door Controller to Reader distance. Relay Contacts Number Number 8 Type 4 state, supervised. Normal, Active, Open, Short Current Rating Relay Type Relay Current 8 - when using Readykey for Windows 4 - when using other systems 2A at 30VDC Latching, with Common, Normally Open and Normally Closed terminals. Each relay only draws a momentary pulse of current as it changes over. 1994 Radionics, Inc. Page 2 74-07213-000-A 4/94

Installation Installation Location The K2015A may be located at any point between the Readykey Door Controller and Reader. However the cable distance between the Door Controller and K2015A must be less than 500m/1500ft. The diagram below shows mounting holes and cable entry facilities. Cable entry may be through the rear of the enclosure or surface mounted using trunking or conduit. Use 3 screws suitable for the mounting surface. Use the top screw to attach the unit first, and then use the bottom two holes as a template. Holes for cable tie-wrap Cover secured by self-tapping screws 92 / 3.6 20 / 0.75 42 / 1.6 148 / 5.8 130 / 5.1 20 / 0.8 25 / 1.0 Tamper Switch 18 / 0.7 35 / 1.35 140 / 5.5 184 / 7.2 3 / 0.13 Surface Entry: Circular knockout on each side, 20mm/0.8in diam. Rectangular cover on each side, 42mm/1.6in x 20mm/0.75in Rear Entry: Four Rectangular holes, 40mm/1.5in x 20mm/0.75in Note: The K2015A may be connected to any Door Controller reader channel, with or without a Reader. 74-07213-000-A 4/94 Page 3 1994 Radionics, Inc.

Installation Max. Total Distance: 1000m / 3000ft Max. Distance: 500m / 1500ft K2015A with Reader Reader Alone Readykey Door Controller K2015A without Reader K2015A Alarm Event Manager Configuration Options Connections to Door Controller and Reader All connections are made to removable terminal blocks. Note: ensure that the Door Controller cable is disconnected at the Door Controller before carrying out work on the K2015A. Cable Specification Type 6 conductor, multi-stranded, unshielded cable *Distance/Gauge Up to 250m: 0.22mm² Up to 750ft: 24 AWG Up to 500m: 0.50mm² Up to 1500ft: 20 AWG Up to 1000m: 1.00mm² Up to 3000ft: 18 AWG * Total Door Controller to Reader distance. The Reader may be any type of Readykey Reader. This includes K2001-P PIN Readers which previously were not compatible with the K2015A Alarm Module. See the Door Controller Installation Manual for full details of the Reader wiring options. Door Controller -V SIG DR1 DR2 LED +V Door Contact N/C N/O Request to Exit -V VCA SIG +V Reader Tamper Switch -V SIG DR1 DR2 VCA+V -V SIG DR1 DR2 VCA+V CONTROLLER READER K2015A Alarm Event Manager Two options for enclosure tamper detection are provided. -V SIG DR1 DR2 VCA+V A spring switch that opens when the cover is removed. READER If NO Reader connected, join DR1 and SIG to -V to ensure Tamper Protection A pair of terminals that may be taken to an external, normally closed tamper switch. If both of these contacts are open then the K2015A will indicate a Tamper Alarm. To inhibit tamper reporting completely, connect the TAMP terminals together. 1994 Radionics, Inc. Page 4 74-07213-000-A 4/94

Installation Note: In order to detect enclosure tamper, door monitoring must be set from the administration system. This will require a Door Open Time to be entered for the reader channel. To avoid alarm conditions when no reader is connected to the K2015A, the DR1 and SIG terminal of the reader connector must be connected to -V at the reader connector of the K2015A. Inputs There are 8 supervised inputs available on the K2015A. The detectors may be either Normally Closed or Normally Open. The type of detector is set using the switch bank on the left of the circuit board, below the tamper switch. If the switch is to the left (factory setting) then the detector is Normally Closed, if to the right, Normally Open. N/C N/O 8 7 6 5 4 3 2 1 Input Number Two resistors are used to enable 4 different states to be detected, depending on the position of the detector and/or tamper switches. A 4.7K resistor is connected across the detector contacts, a 2.2K resistor is connected in-line. This gives a resistance (and voltage) on the detector loop corresponding to the various possible states as follows: State Resistance (Ω) Voltage (VDC) Short 0-1.5K 0-1.25 Normal * 1.5-3.1K 1.2-2.0 Active * 3.1-18.6K 2.0-4.0 Open over 18.6K over 4.0 * When using Normally Closed detectors. For Normally Open detectors these states are reversed. Note: It is possible to put up to Three Normally Closed detectors in series. This will produce an Active condition if any one, or more, detectors are activated. A Normal state will return when all the detectors close. However, only One Normally Open detector may be used on each input. The diagrams below show the two types of resistor supplied with the K2015A, the detector circuit diagram and a typical detector such as a PIR. 74-07213-000-A 4/94 Page 5 1994 Radionics, Inc.

Installation 2.2K Resistor Red Brown Red Red Normally Closed Detector Circuit Tamper 2.2K Detector 4.7K Typical Detector, e.g. PIR Tamper Alarm 2.2K 4.7K 4.7K Resistor COM 1-8 Yellow Violet Red Brown Tamper Normally Open Detector Circuit 2.2K Detector 4.7K To COM To 1-8 Relay Outputs COM 1-8 When using detectors that require power, a separate power supply should be used. The only power available at the K2015A is the 18v DC supply from the Door Controller reader channel. The power available from this output is limited and should not be used for providing power to detectors. Note: Any unused inputs should have a 2.2K resistor across the COM and Input number. This will mean that the input will always report as 'normal'. This is useful when diagnosing faults. Note: Relays 5 to 8 are only available to systems administered by Readykey for Windows. Each relay (note that they are numbered from the right) has a Common (COM), Normally Closed (NC) and a Normally Open (NO) contact. When a relay is activated the contact changes over from NC to NO. For how long the relay stays activated, or if there is any delay or time limit depends entirely on the type of Door Controller and Administration System being used. COM NC NO You should consult the documentation for the Door Controller and Administration System being used for full details of available Relay functions. 1994 Radionics, Inc. Page 6 74-07213-000-A 4/94

Testing Testing A diagnostic facility is built in to the K2015A. This is used by pusing the button viewing the 2 digit display. The status of each input, the tamper switch and each relay can be determined. Normal Display: Both decimal points should flash once per second. To Test the Input Status: Press test button. The display will show an input number (1-9) with its status (0-3), press button again to display the next input number. Input 9 is the Tamper status. Input Status codes are: 0 Normal, 1 Active, 2 Short, 3 Open. Tamper (Input 9) Status Codes are: 0 No Tamper, 1 Reader Tamper, 2 Case Tamper, 3 Both Tampered Examples (left) show: 10 - Input 1: Normal 41 - Input 4: Active 92 - Tamper: Case Using the test button you can check each input in turn. A correctly wired detector should show a status of 0. When activated the status should change immediately to 1 - and return to 0 when the detector returns to its normal state. A state of 2 (short) means the input is short-circuited, a state of 3 means the input is open circuit. Software Features The functions available from the K2015A depend entirely on the combination of Door Controller and Administration System. The combinations break down into 3 Groups: 1 K2000-N Door Controllers Administration System 2 K2100/K1100 - without Readykey for Windows Administration System All, excluding Readykey for Windows 3 K2100/K1100 with Readykey for Windows Administration System Readykey for Windows only K2000-AM, K2000-N Door Controllers K2000-AM All The K2015A behaves exactly as the previous K2015 Alarm Module. However please note the following: Detectors should still be wired as described here using the two resistors. In this case any change of state from Normal will be treated as an alarm condition. Only the first 4 relays are available. Use the MR (responses) and MS (sensors) commands to program the K2015A either on the Master (K2000-AM) or Slave (K2000-N) Door Controllers. 74-07213-000-A 4/94 Page 7 1994 Radionics, Inc.

Software Features K6000-AM, Office Administration Kit Select 3 Alarm Functions from the Main Menu. Use 2 Monitoring Responses and 3 Monitoring Sensors to program the K2015A either on the Master (K2000-AM) or Slave (K2000-N) Door Controllers. K6000-SS, K6000-MS w/k2000-n If using version 2.6 or above you should first ensure that the Alarm Sensor Record type is set. This is found from the Main Menu in 8 System Configuration, 8 Installation Configuration, 1 PC Configuration, 9 Set Alarm Sensor Type. This should be set to K2000-N Sensor Records. Select Alarm Functions from the Main Menu. Use 2 Monitoring Responses and 3 Monitoring Sensors to program the K2015A on the Slave (K2000-N) Door Controllers. If you have a mixture of K2000-N and K2100/K1100 Door Controllers on the system,. then make sure you have upgraded the K6000 PC software to Version 2.5 or above. For programming K2100/K1100 Door Controllers see the section below. Readykey for Windows Readykey for Windows allows you to state the type of each Door Controller and Alarm Module (K2015 or K2015A). Provided this is done correctly then only the facilities appropriate to that combination of devices will be allowed. K2100, K1100 - non Readykey for Windows When the K2015A is connected to a K2100 or K1100 Door Controller it behaves as if a K2015 Alarm Module. However note the following points: Only the first 4 relays are available. An input can activate a relay on any K2015A on the same Door Controller (except Relay 4 on the 4th channel) Each relay can be programmed to respond to a System Event, or to operate according to a Time Profile. K2100 - Master Controller Use the MR (responses) and MS (sensors) commands to program the K2015A inputs either on the Master or Slave (K2100/K1100 Slave or K2000-N) Door Controllers. Use the RE command to program the relays to operate according to System Events or Time Profiles. K6000-AM, Office Administration Kit Note: It is not recommended that a K2100 or K1100 is used as part of a K6000-AM Office Administration System, if you intend to attach K2015 Alarm Modules or K2015As. See: Using Binary Programming Tech Note K6000-SS, K6000-MS If you are using K2100 Door Controllers on a K6000 system and wish to use K2015 Alarm Modules or K2015As, then you should upgrade to Version 2.6 or above. You should first ensure that the Alarm Sensor Record type is set. This is found from the Main Menu in 8 System Configuration, 8 Installation Configuration, 1 PC Configuration, 9 Set Alarm Sensor Type. This should be set to K2100 Sensor Records. Select Alarm Functions from the Main Menu. Use 2 Monitoring Responses and 3 Monitoring Sensors to program the K2015A on the Slave (K2100) Door Controllers. Relay programming is included in the Monitoring Sensors screen. 1994 Radionics, Inc. Page 8 74-07213-000-A 4/94

K2100/K1100 Door Controllers with Readykey for Windows The full potential of the K2015A Alarm Event Manager is realized when used with Readykey for Windows. This includes: All 8 Relays are available for programming. Software Features Tamper (Open Circuit) and Trouble (Short Circuit) states are reported, along with Restorals. A wide range of system events can be used to activate Relays, as well as Time Profiles. Ensure that the type of each Door Controller is properly defined in Installer:Door Controllers, and the type of each Alarm Module is defined in Installer:Alarm Modules. Only if this is done will all the correct features be available. Note: as Readykey for Windows establishes all the inputs for a K2015 Alarm Module or K2015A when the record is added, you should ensure that all the K2015A inputs are terminated. This is described in the section above on Inputs. 74-07213-000-A 4/94 Page 9 1994 Radionics, Inc.

Software Features Radionics, Inc. 1800 Abbott Street Salinas, CA, 93901, USA Customer Service: (800) 538-5807