Energy Division

Similar documents
Section 8: Switchgear Connections (Straight & Elbows)

Heat-Shrinkable Termination System for Cables up to 36 kv

RICS. Insulated adapter termination system for SF 6 -insulated switchgear up to 24 kv

RICS. Insulated adapter termination system for SF 6 -insulated switchgear up to 24 kv

Terminations. Energy Division. Return to Contents

Section 4: Medium Voltage Terminations - up to 42kV.

Energy Division Heat-shrinkable joints for halogen-free, flame-retardant and fire-resistand cables up to 1 kv

Raychem heat-shrinkable medium voltage terminations IXSU-F/OXSU-F for indoor and out door applications for polymeric cables up to 42 kv

Section 7: Cable Glands & Duct Seals.

MXSU - Selection table 3-core Kits / X-section

Energy Division. CSJT MV cold shrinkable joint for 3-core cables with resin encapsulation

Energy Division. CSJR / CSJH Cold shrinkable straight joints for polymeric insulated cables up to 36 kv

Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series. Energy Division

Raychem Elastomeric Medium Voltage Push-on and Cold-shrink Applicable Terminations TFTI/TFTO

ATUM: General Purpose Thin Wall Tubing - with Adhesive (Black) Medium Wall: MWTM: General Purpose Medium Wall Tubing

Connecting the World of Power ENERGY DIVISION

Section 4: Medium Voltage Terminations - up to 42kV

Reliable solutions for electrified railway systems

PolyGarde Metal-Oxide Surge Arresters

BISG II. Bus Insulator Squirrel Guard. This new and improved isolation guard prevents animal-caused outages in electrical substation equipment.

Energy Division. Raychem Insulation Enhancement Systems

Section 5: Medium Voltage Joints - up to 42kV

ENERGY /// ENERGY ACCESSORIES ENERGY ACCESSORIES

Insulation and Protection Enhancing the Reliability of Overhead Power Systems

RELIABLE SOLUTIONS FOR ELECTRIFIED RAILWAY SYSTEMS

Energy Division. Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series

Energy Division. DAH series (IEEE) Distribution metal oxide surge arrester

Bowthorpe EMP surge arrester Distribution metal oxide surge arrester DA1 Series, (IEC)

Bowthorpe EMP surge arrester Distribution metal oxide surge arrester DA0 Series, (IEC)

Raychem Saudi Arabia Ltd.

ENERGY PRODUCTS DIVISION. Polymeric Surge Arresters Reliable protection for power equipment upto 800kV

Energy Division. Raychem Raysulate Insulation Enhancement Systems

INDUSTRY /// RAIL T-CONNECTOR RSTI-68R-HT RSTI-CC-68R-HT RAIL APPROVED T-CONNECTORS FOR ROLLING STOCK- TYPE C INTERFACE

ENERGY PRODUCTS DIVISION. Enhancing the Reliability of Cable Networks. Cable Accessories for upto 245 kv

Energy Division. Accessories for the Installation of Low Voltage & Medium Voltage heat-shrinkable products for the Electrical Power Industry

Raychem Raysulate Insulation Enhancement Systems

PETROCHEMICAL SOLUTIONS

RAYCHEM MEDIUM VOLTAGE

HVS S 15kV Class

NPS/003/030 Technical Specification for Transformer and Switchgear Cable Boxes and their associated Bushing Assemblies

Total Fire Solutions. Includes BS 8519 and the updated BS :

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

Raychem Link Boxes. Cable Services Limited. Powering the UK

HVS S Splice Series

TE S RAYCHEM PLUG-IN TERMINATIONS (RPIT) INNER CONE SYSTEMS FOR SWITCHGEARS AND TRANSFORMERS UP TO 52 kv

TECK-40 Series 1000V Class Splice for 4/C Armored Teck Power Cables

LOW VOLTAGE HEAT SHRINK JOINTS TECHNOLOGY CONNECTING YOUR NEEDS TO TOMORROW S NETWORKS

Annex "Connection systems" to the manufacturer's declaration no /06/E

Catalogue Power Cables

INTER PLANT STANDARD STEEL INDUSTRY

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

RF one-step BNC/TNC connectors for coaxial cable termination

TECHNOLOGY WEDGE PRESSURE HV JUICE PAGES 2 & 3. Pop-N-Work Pop-Up Tents PAGE 5. June/July This Issue.

Traction Cable Radox 3 GKW

RAYCHEM SCREENED SEPARABLE CONNECTORS RSTI FOR SWITCHGEARS AND TRANSFORMERS IN MEDIUM VOLTAGE DISTRIBUTION NETWORKS

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

Catalogue. Instrumentation & Control Cables

SolderSleeve Insulated Electrical Termination Devices

SPECIFICATION FOR GAPLESS METAL OXIDE DISTRIBUTION TYPE SURGE ARRESTERS WITH POLYMERIC HOUSING

LOW VOLTAGE SPLICES & TAPS

Transportation. Distribution

DNVGL-CP-0399 Edition March 2016

Lloyd s Register Type Approval System Test Specification Number 3

WILDLIFE AND ASSET PROTECTION

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

DNVGL-CP-0401 Edition February 2016

JGK-MS-2/3 Jacketed Concentric Neutral Cable Mid-Span Grounding Kit

Data Sheet. Self regulating heating tapes. RS stock numbers

C Electrical Connection Kit

Cable technology for highest safety requirements

XAGA 550/550-L. Aerial Splice Closure. 1. General Description. 2. Warnings. 3. Cautions

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

Side Entry Insulation Damage Repair Sleeve (SEIDRS) Raychem Devices Products

Qualification Test Report 1/Jul/2005 Rev. A

Cartridge Heaters. Metric FIREROD Cartridge. Applications and Technical Data

Qualification Testing of Nuclear High Voltage Splice (NHVS) Title Pages: 49. Report Number: EDR-5391 Rev. 0 06/15/05. Approved by: Signature: Date:

GMA Panels with double busbar

HV JUICE. RAYCHEM RAYSULATE Asset & Outage Protection. ECOLight Solar LED Streetlight Kit. June/July This Issue PAGE 4-5 ECO.

energy.te.com ONE CLEAR SOLUTION FOR BOTH ROUGH ENVIRONMENTS AND TOUGH SPECS.

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Heavy Head Hand Crimping Tools (HHHT) [ ]

SAFE, FAST PROFESSIONAL WIRING SOLUTIONS STANDARDISED & INDIVIDUAL COMPLEX SMART SOLUTIONS. 25 years: You name it. We have it. DANNEWITZ GmbH & Co

Always ahead of the game with the Klauke product range for utility companies

IECEx Certificate of Conformity

FOSC. Fiber Optic System Technology. Fiber Optic Splice Closures (FOSC-400)

Author Owner Issue Authority Name: Gordon MacKenzie Title: Senior Engineer Engineering Design and Standards

HEAT SHRINK CABLE ACCESSORIES: A 40 YEARS PROVEN TECHNOLOGY FOR APPLICATIONS IN HARSH ENVIRONMENTS

GENERAL SPECIFICATION ELECTRICAL

SWITCHING SWITCHING. Overhead Electric Distribution Standards INTRODUCTION

Band Heaters W A T L O W. Special Mica Barrel and Nozzle

REGISTER OF NEW NATIONAL STANDARDIZATION INITIATIVES NOTIFIED UNDER SUBSECTORS IN THE SCOPE OF CENELEC. November 2016

Band Heaters. Rectangular Band Heaters, Strip, Ring and Flat Heaters. Contact Accessories, Connection Boxes, Clamping Devices

Frost Protection Thermostat

DESIGN GUIDELINES. THERMAL building SOLUTIONS

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

SECTION ELECTRICAL IDENTIFICATION

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

PRODUCT CATALOGUE Norröna

INSTALLATION INSTRUCTIONS FOR 7330*5511 OR 7330*5512 MOUNTING KIT 7330B751 CONTROL BOX KIT (12 VDC COOL ONLY)

Transcription:

Energy Division http://energy.tycoelectronics.com Terminations for polymeric and MIND paper insulated cables from 7.2 kv up to 36 kv System Designer R

Termination systems designer This worksheet enables you to arrive at a part number for an EPKT termination. Choose one figure from the left-hand column of each table. Typical part number: EPKT- 17C3MOH3 B21 G43 Voltage (U max ) Cable size Number of cores Dielectric Location Length (3-core-cables) Accessories Voltage in kv 7 for 7.2 kv 17 for 12 kv & 17.5 kv 24 for 24 kv 36 for 36 kv Size in mm 2 7.2 kv 12 kv & 17.5 kv 24 kv 36 kv A 16-50 16-25 - - B 70-120 35-70 25-50 - C 150-240 95-240 70-185 50-95 D 300-500 300-400 240-300 120-185 E 630-1000 500-800 400-630 240-500 F - 1000 800-1000 630-1000 No. of Cores 1 for single (1) core 3 for three (3) core Dielectric X M of insulation type for PLASTIC eg. XLPE, EPDM, EPR, etc. for MIND non-draining paper (not applicable for draining paper cables) Location I O of the termination for INDOOR for OUTDOOR Length (only 3-core) H1 H2 H3 H4 of the terminated portion (tail) for 450 mm long for 650 mm long (min for 17.5 kv outdoor & 36 kv indoor) for 800 mm long (min for 24 kv outdoor & 36 kv outdoor) for 1200 mm long

Armour Earthing Wire armour in paper or plastic cables can be effectively terminated to earth by means of mechanical clamping rings. Heat-shrinkable tubing for corrosion protection and an insulated copper conductor for earth connection are also included. The kits can be ordered separately or with the termination by adding the mod code to the end of the part number. 1-core cables Diameter Application Range (mm 2 ) Part Number Mod Code Range (mm) 7.2 kv 12 kv 17.5 kv 24 kv 36 kv 21-32 16-70 16-70 16-50 16-50 - EAKT 1636 G 36 33-50 95-400 95-400 70-400 70-300 16-185 EAKT 1637 G 37 51-67 500-800 500-800 500-800 400-800 240-630 EAKT 1638 G 38 3-core cables Diameter Application Range (mm 2 ) Part Number Mod Code Range (mm) 7.2 kv 12 kv 17.5 kv 24 kv 36 kv 40-67 16-120 16-120 16-95 16-35 16-25 EAKT 1642 G 42 50-86 150-240 150-240 120-185 50-120 35-95 EAKT 1643 G 43 60-94 300-400 300-400 240-300 150-185 120-185 EAKT 1644 G 44 70-110 - - - 240-300 240-300 EAKT 1645 G 45 Cable Preparation Kit Two types of cable preparation kits are also available. The one for paper cable contains cleaning solvent, solder and binding wire. The one for plastic cable contains abrasive paper, string, cleaning tissues and plastic gloves. These can only be ordered along with terminations by adding the mod code to the end of the part number. Application Mod Code Paper cable E 01 Plastic cable E 02

Cable Glands The Raychem cable gland is used with a wide range of cable boxes designed for compound filling where the distance from bushing to baseplate is al limiting factor. The gland is made to match stud spacings to BS 2562. It is also available with an insulating plate for separate earthing and of aluminium for single core applications. These can be ordered separately as complete kits or along with the termination by adding the mod code at the end of the part number. Application Part Number Mod Code Steel/Small/X-Type/cables up to 95 mm 2 EAKT 1605 G 05 Steel/Large/Y-Type/cables up to 300 mm 2 EAKT 1606 G 06 Steel/Large/Y-Type/with insulating plate EAKT 1607 G 07 Aluminium/Small/X-Type/1-core application EAKT 1608 G 08 Note: The stud hole spacing in the small gland is 66 mm x 66 mm and in the large gland is 86 mm x 95 mm. Solderless Earth Connection Copper tape screens on plastic cables can be earthed mechanically by using Raychem's solderless earth connection system. The kit comes complete with a tinned copper earthing braid and a mechanical roll spring for each phase. These can be ordered separately as kits or with the termination by adding the mod code to the end of the part number. Diameter over Application Range (mm 2 ) Part Number Mod Code Screen (mm) 7.2 kv 12 kv 17.5 kv 24 kv 36 kv 12-18 16-50 16-50 16-25 - - EAKT 1655 G 55 19-24 70-150 70-150 35-95 25-70 25-35 EAKT 1656 G 56 25-30 185-300 185-240 120-185 95-150 50-70 EAKT 1657 G 57 31-44 400-630 300-630 240-500 185-500 95-300 EAKT 1658 G 58 41-65 800-1000 800-1000 630-1000 630-1000 400-1000 EAKT 1659 G 59 Note: Solderless earth connections are also available for lead sheaths on paper cables. For such requirements please contact your local sales representative.

Boots Insulating boots are moulded parts which are shrunk over the connection between the cable lug and bushing to insulate them. They are used in switchgear and transformers with compound filled boxes where the clearances are insufficient for operation in air or to protect against flash over due to rodents or extreme humidity. A full range of insulating boots are available up to 17.5 kv. These can be ordered separately by quoting the part number or with the termination by adding a mod code to the end. Example: EPKT-17C3MOH3-B07 This kit comes complete with straight boots. Application range Straight boots Right angle boots - long Right angle boots - short Mod Code Part Number Mod Code Part Number Mod Code Part Number 10-35 mm 2 B05 RSRB 4022 B08 RSRB 4042 B15 RSRB 4062 50-95 mm 2 B06 RSRB 4024 B09 RSRB 4044 B16 RSRB 4064 120-300 mm 2 B07 RSRB 4026 B10 RSRB 4046 B17 RSRB 4066 Note: 1. Long boots are 110 mm long over the bushing. The short boots are 90 mm long. 2. Insulating boot kits are also available for up to 36 kv applications. For such requirements please refer to your local sales representative. Support Insulators and Bracket Raychem also manufactures a range of hybrid insulators. The sheds of red, non tracking, flexible polymeric material are mounted on a porcelain core. Sets of three, along with a galvanised steel T-bracket, can be ordered for applications up to 36 kv either as separate kits by quoting the part number or with the termination by adding the mod code to the end. Reference standard IEC 60815, IEC 60071 Part Number Mod Code Description EAKT 1521 B 21 Insulator Kits 12 kv to 24 kv (light pollution) EAKT 1521 B 21 Insulator Kits 12 kv (heavy pollution) EAKT 1523 B 23 Insulator Kits 36 kv (light pollution) EAKT 1523 B 23 Insulator Kits 17.5 kv to 24 kv (heavy pollution) EAKT 1524 B 24 Insulator Kits 36 kv (heavy pollution) Note: The voltage is the highest phase-to-phase voltage U max.

RICS Insulated adapter termination system for SF 6 -insulated switchgear up to 24 kv T-adapter for perpendicular connection of the termination to SF 6 -insulated switchgear T-adapter for perpendicular connection of termination and surge arrester to SF 6 -insulated switchgear Straight adapter for vertical connection of the termination to SF 6 -insulated switchgear T-adapter The insulated adapter termination system provides perfect sealing, electrical insulation and an electrical connection between Raychem terminations and SF 6 -insulated switchgear up to 24 kv. Its lead-in insulator (630 A) conforms to DIN 47636 and ANSI IEEE 386. The cable box of the switchgear must be provided with suitable protection against electric shock. The insulating adapter is compatible with all Raychem terminations. Details of the terminations can be found in the cable accessories catalogue. The insulating body, fixing bolts, terminal stud and backplug are supplied in a 3-phase set complete with installation instruction. Cable lugs and terminations are not included. For double T-connections, the second adapter is of special design and includes connection plug, insulating body, fixing bolts, terminal stud and backplug. It can be combined with first adapters of type RICS-57x3-CU with M16 lugs, but not with adapter for surge arresters type RICS-51x9 T-adapter with surge arrester Thick walled insulator made of high quality elastomer with sealing face over the termination, bushing cone and plug. The electrical connection is made with a terminal stud and the cable lug of the termination. Two cable connection is possible. A special plug which allows cable testing without disconnecting the adapter is also offered. The design of the adapter for connecting the surge arrester is basically identical. The elastomer insulator has an additional lead-in duct for the surge arrester. Details of the surge arresters can be found in the brochure EPP 0533. Scope of supply (for three phases) Insulator, plug, terminal stud, small accessories and installation instructions. Straight adapter A thick walled, heat-shrinkable insulating sleeve provides a hermetic seal over the cone of the bushing and the termination. The adapter area is smoothed with a meltable filler strip. Scope of supply (for three phases) Heat-shrinkable insulating sleeving, filler strip, small accessories and installation instructions. Terminal stud and lug must be enclosed.

RICS Insulated adapter termination system for SF 6 -insulated switchgear up to 24 kv RICS T-adapter Voltage class Cable type Application range Type of indoor Part Number (U 0 / U (Um)kV (mm 2 ) termination 6.35 / 11 (12)kV Polymeric 1C & 3C 25 to 50 IXSU-F, POLT, EPKT, TFTI RICS 5113 70 to 150 RICS 5123 185 to 240 RICS 5133 300 RICS 5143 8.7 / 15 (17,5)kV Polymeric 1C & 3C 25 to 35 IXSU-F, POLT, EPKT, TFTI RICS 5113 50 to 95 RICS 5123 120 to 185 RICS 5133 240 to 300 RICS 5143 12.7 / 22 (24)kV Polymeric 1C & 3C 10 to 70 IXSU-F, POLT, EPKT, TFTI RICS 5123 95 to 185 RICS 5133 240 to 300 RICS 5143 6.35 / 11 (12)kV Paper (MI and MIND) 35 EPKT-45xx RICS 5113 Belted 50 to 95 RICS 5123 120 to 185 RICS 5133 240 RICS 5143 6.35 / 11 (12)kV Paper (MI and MIND) 35 to 70 EPKT RICS 5113 Screened or belted 95 to 150 RICS 5123 185 to 240 RICS 5133 300 RICS 5143 RICS T-adapter with Surge Arrester Voltage class Cable type Application range Type of indoor Part Number (U 0 / U (Um)kV (mm 2 ) termination 6.35 / 11 (12)kV Polymeric 1C & 3C NA IXSU-F, POLT, EPKT, TFTI NA 185 to 240 RICS 5139 300 RICS 5149 8.7 / 15 (17,5)kV Polymeric 1C & 3C NA IXSU-F, POLT, EPKT, TFTI NA 120 to 185 RICS 5139 240 to 300 RICS 5149 12.7 / 22 (24)kV Polymeric 1C & 3C NA IXSU-F, POLT, EPKT, TFTI 95 to 185 RICS 5139 240 to 300 RICS 5149 6.35 / 11 (12)kV Paper (MI and MIND) NA EPKT-45xx Belted NA 120 to 185 RICS 5139 240 RICS 5149 6.35 / 11 (12)kV Paper (MI and MIND) NA EPKT Screened or belted NA 185 to 240 RICS 5139 300 RICS 5149 Tests The adapters meet Cenelec HD629.1S1, IEC 540, VDE 0278 and ANSI IEEE 386 standards, as well as the Raychem specification PPS 3013, in addition they were type tested together with most switchgear. The test requirements and results are summarised in Raychem test reports, which are available on request.

RCAB Elastomeric insulating bushing boot for bushings up to 17.5 kv and 24 kv RCAB right angle or inline application up to 17.5 kv RCAB inline application up to 24 kv Raychem elastomeric insulating boots are moulded parts which fit over the connection between the cable lug and the inline or rightangled equipment bushing to improve phase-to-phase and phaseto-ground insulation. They are used in switchgear and transformer cable boxes where the air clearances are insufficient for normal operation, or to protect against flashover due to rodents or high humidity. The non-tracking elastomeric housing has excellent erosion resistance, dielectric properties and environmental resistance, giving superb per-formance in areas of high humidity and electrical stress. RCAB adapter RCAB boots works in combination with all Raychem termination product lines including both elastomeric and traditional heatshrink technology. RCAB boots are quick and easy to install and do not require any taping of the bushing or the termination. The boot can easily be removed and reinstalled without the need for additional material or tooling, allowing access to the bushing connection for test purposes. The universal screw EXRM-1366 is available on request. Each kit contains elastomeric insulating boots, collars (if required) for three phases and installation instructions. The insulating body is supplied in a 3-phase set complete with installation instruction. Fixing bolts, terminal stud and cable lugs are not included. Terminal studs with a M16 thread can be ordered separately as EXRM-1366. The adapter is to be used in combination Raychem teminations. Voltage class Cable type Application range Type of indoor Part Number (U 0 / U (Um)kV (mm 2 ) termination 6.35 / 11 (12)kV Polymeric 1C & 3C 35 to 300 IXSU-F, POLT, EPKT, TFTI RCAB 4120 12.7 / 22 (24)kV Polymeric 1C & 3C 50 to 300 IXSU-F, POLT, EPKT, TFTI RACB 5120 Tests The adapters meet Cenelec HD629.1S1, IEC 540, VDE 0278 and ANSI IEEE 386 standards, as well as the Raychem specification PPS 3013, in addition they were type tested together with most switchgear. The test requirements and results are summarised in Raychem test reports, which are available on request. All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale. ALR, AMP, AXICOM, B&H, BOWTHORPE EMP, DORMAN SMITH, DULMISON, GURO, HELLSTERN, LA PRAIRIE, MORLYNN, RAYCHEM, and SIMEL are trademarks. CROMPTON is a trademark of Crompton Parkinson Ltd. and is used by Tyco Electronics under licence. Energy Division a pioneer in the development of economical solutions for the electrical power industry. Our product range includes: cable accessories, connectors & fittings, electrical equipment, instruments, lighting controls, insulators & insulation enhancement and surge arresters. Tyco Electronics EPP 0282/2 2/05 For more information and your country contact person, please visit us at: http://energy.tycoelectronics.com Tyco Electronics Raychem GmbH, Energy Division Finsinger Feld 1, 85521 Ottobrunn/Munich, Germany Phone: +49-89-6089-0, Fax: +49-89-6096345