169MHz Telecare Devices Gas & Carbon Monoxide Detector

Similar documents
169MHz Telecare Devices. Gas Detector

169MHz Telecare Devices Carbon Monoxide Detector

169MHz Telecare Devices Heat Detector

169MHz Telecare Devices Deaf Smoke Alarm Kit

Carbon Monoxide Detector

169MHz Telecare Devices Enuresis Sensor & Plastic Bed Mat

169MHz Telecare Devices Touch Personal Pendant

169MHz Telecare Devices Companion Epilepsy Monitor

169MHz Telecare Devices Universal Transmitter

169MHz Telecare Devices Sensor Controller

USER & INSTALLATION GUIDE

Operators Guide ENGENIUS EP800 CORDLESS TELEPHONE

Door Monitor V3.00a Installation Guide

Pendant V3.00a Installation Guide

NG-9B NATURAL GAS ALARM

WIRELESS GAS DETECTION & SHUT OFF SYSTEM INSTRUCTION MANUAL. Wireless Gas Detection & Shut Off System - User Manual & Instructions

ADVENT xt WARDEN CALL SYSTEM V2.0 OPERATORS MANUAL

USER & INSTALLATION GUIDE

CO-9X User Manual 6 YEAR LIFE CARBON MONOXIDE POISONOUS GAS ALARM

CO-808S User Manual. Carbon Monoxide Poisonous Gas Alarm With Sealed 6 Year Power Pack

Carbon Monoxide Room Alarm Installation and User Guide Part No:

WARNING FIRE DOOR CLOSING

Programming the Vi+ using a Series Telephone. Tunstall Vi+

Installation and User Guide

60cm Chimney Extractor

7 YEAR LIFE CARBON MONOXIDE POISONOUS GAS ALARM

TS400 & TS410. Intruder Alarm Control Panels. Operating Instructions

COSTER. Code Internal Alarm Pre-alarm Suitable sensor threshold threshold external sensor

0 4 / 0 4 / 1 4. GE Concord 4 Quick User Guide. GE Concord 4 Quick User Guide Page 1

Total Connect Box. User manual

OPEARATING GUIDELINES FOR AERO-252 (Pages 1 to 3 contain general information on CO Guardian. Pages 4 to 6 contain information specific to Aero 252)

SAFETY & SECURITY SAFETY & SECURITY

Safety Siren. Owner's Manual. Family Safety Products Inc. Carbon Monoxide, Propane & Methane. Model Number HS80004 HS80104 HS80204 HS80504 DETECTOR

BWT6.3GL Cooker Hood 60 cm Glass chimney hood

Introduction Carbon monoxide (CO) is a colorless, odorless and tasteless gas which is toxic and can quickly become a mortal danger. Amongst others, ca

Model No: Little Devil II (inc ss)

CERAMIC HEATER MODEL NO: DEVIL 350B 230V/110V OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS GC ISS 1

Firehawk Fire Alarms Battery Powered. Information, Installation and Maintenance

Comhshaol, Pobal agus Rialtas Áitiúil Environment, Community and Local Government. Fire safety at home

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

U S E R M A N U A L UBH1RF HEAT ALARM

Control Panel User Guide

BWTC6510GL Cooker Hood 60 cm Glass cooker hood in stainless steel. BWTC9510GL Cooker Hood 90 cm Glass cooker hood in stainless steel

Ultra-8D. ControlPanel. Operators Manual. Advanced DigitalControls CP108-0M-V1

DIGITAL 7 YEAR LIFE CARBON MONOXIDE ALARM

B16351-R0-Ei2100 SERIES-USE.qxd 18/9/08 3:47 PM Page 1 230V~ MULTI-SENSOR FIRE ALARM with Rechargeable Lithium Cell Back-up.

UPON COMMENCMENT OF INSTALLATION IT IS OF PARAMOUNT IMPORTANCE THAT THE STEP BY STEP GUIDE (INCLUDED) IS FOLLOWED COMPLETELY

Smoke Alarm User s Manual

SMOKE DETECTOR USERS GUIDE SMOKE DETECTOR SETUP GUIDE

BT16.4SS-HK BT19.4SS-HK Cooker Hood

Digital Electronic Thermostat With RF

Installation and user guide

UBS1RF OPTICAL SMOKE ALARM EN 14604:2005/AC:2008 DOP:UBS1RF-001-V1

U ser's Guide PC6010

PARAFFIN/DIESEL HEATER

Digital Electronic Thermostat With RF

USER INSTRUCTIONS MULTI-SENSOR FIRE ALARM 230V~ with Rechargeable Lithium Cell Back-up. Model: Ei2110

Resident Maintenance Manual

B16008-R0-160RC SERIES-U&C 17/1/07 11:13 AM Page Installation Guide

CARBON MONOXIDE DETECTOR, i4h-co-m330

USER GUIDE WIRE-FREE HOME PROTECTION SYSTEM AG100+ CONTENTS

USER MANUAL 10 YEAR LIFE SMOKE ALARM

TYNETEC. Telecare for independent living THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES MOBILE NETWORK

Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System

DIGITAL 7 YEAR LIFE CARBON MONOXIDE ALARM (Includes all colour variants)

Quick Installation Manual LED 99-Zone Autodial Wireless Alarm System

NetworX NX-8V2. LED Keypad User Manual

Lifeline 400 user guide q6 18/2/04 10:56 am Page 2. Lifeline 400. installation and user guide. Part Number D B

L900 series USER MANUAL

Universal Sensor. Installation Guide. t: f: e: w: uk.tunstall.com Version: V2.97 (421V0R1.

DIESEL/PARAFFIN HEATERS

Macurco HD-11 Hydrogen Gas Detector

User's Instructions. Alpha CD24C/32C. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

Macurco HD-11 Hydrogen Gas Detector User Instructions. Important: Keep these User Instructions for reference

Model LP USER S MANUAL AND INSTALLATION INSTRUCTIONS

Wireless Interlink Smoke Alarm + 10 Year Life

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

TYDOM 315. * _Rev.2* GSM domotics transmitter. 1. Presentation

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time

Gas Leak Detection Alarm

HILLS Series LED Code Pad User Manual

PLAN NOW!! Plan your escape today Your life may depend on it tomorrow HOME ESCAPE PLAN EXERCISE

NX-148 LCD CODE PAD TABLE OF CONTENTS

NextGen Home Security. Quick Reference Guide

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

CSP-204 CSP-208 CSP-104 CSP-108

Electronic Smoke Detector m-rmf150

GUH52SD 52 cm GUH75 75 cm Canopy Hood

RadioLINK Alarm Base. Instructions. Model: Ei168RC

Wireless Security System

Datasheet CALYPSO II R. Interlinkable smoke alarm device

Control/Communicator Installation Manual

ABORT Light flashes during an abort delay time; is on during or after an alarm report to the central station. EMERGENCY ACTIVATION KEYS

ASHDOWN STOVE SUITE

PRODUCT GUIDE & INFORMATION. Professional Fire & Carbon Monoxide Solutions

Smoke Alarm User Manual

Heat Alarm User s Manual

Gas Safety. Information for homeowners. orbit.org.uk

Control Panel. Operators Manual TO SUIT AS216 KEYPAD. AS216-OM-6.2. Advanced Digital Controls

WLS900 Wireless Security System. Table of Contents. Your installing company is, Name: Address: Phone: Your monitoring station is, Name: Phone:

Transcription:

169MHz Telecare Devices Gas & Carbon Monoxide Detector Compatible with Reach at-home alarms, Advent xt warden call, Altec Response and Touchsafe Pro Nursecall systems Gas alarm activates at 10% of Lower Explosive Limit alarm activates on Time Weighted Average; 30ppm 2hrs, 50ppm 1hr, 100ppm 10mins or 300ppm 0-3mins 85dB @ 3m sounder Indicator lights: green power, yellow fault & red alarm Requires connection to 240V AC mains supply via a fused spur Transmitter low battery warning Complies with EN50194 (Gas) & EN50291 () Backplate dimensions: 175 x 140mm (depth = 55mm) Weight: 640 grams Product Code: ZXT427 Where should Gas & Carbon Monoxide Detectors be fitted? Combined Gas & Carbon Monoxide () detectors should be fitted in all rooms with a fuel burning appliance such as a boiler or gas cooker and where a lot of time is spent e.g. the kitchen or living room. They should not be fitted in the bathroom or areas subject to steam, damp or humidity. Choosing a Location The combined gas & detector should be wall mounted in the highest part of the room, approx 300mm from the ceiling and between 1 and 5 metres from the appliance. The combined gas & detector should not be located inside a cupboard, behind a curtain, directly above the cooker or sink, next to a door or window or near an extractor fan. The combined gas & detector should be within 5 metres of a mains supply otherwise the cable provided will need extending. Typical Tools Required Be careful when using step ladders always face the direction you are working. Always make sure the correct drill bits and screwdrivers are used. Installation 1. IMPORTANT: BS EN50244:2016 Electrical apparatus for the detection of combustible gases in domestic premises states that detectors should be permanently installed and it should not be possible to switch off power to the device, unless for maintenance. A plug and socket type connection should not be used, due to the ease with which the detector may be disconnected from the power supply. 2. Fix the mounting plate complete with detector to the wall using the screws and plugs provided through the 4 fixing holes. 3. The detector should be wired to the mains supply by a qualified Electrician using the flexible cable provided to a fused spur outlet fitted with a 3A fuse to BS1363-4 and BS1362 respectively, or according to local regulations. 4. Apply the mains power and the GREEN ON light will FLASH for about 2 minutes during the sensor warm-up period. The unit is operating when the GREEN ON light is lit steady. Mains Connection 4 x FIXING HOLES INDICATOR LIGHTS Colour Brown Blue Grn/Yel Terminal Live Neutral Earth Doc No. FM0471 issue G Page 1 Tynetec and Aidcall are business units of Legrand Electric Ltd Unit 10 Cowley Road, Blyth Riverside Business Park, Blyth Northumberland, NE24 5TF. Tel: 01670 352 371 Fax: 01670 362 807 Email: sales@tynetec.co.uk Web: www.tynetec.co.uk

Testing & Registering the Gas & Detector The and pushbuttons on the lid are used when registering the combined Gas & detector onto the warden call system, at-home alarm or Nursecall system. See the following pages for how to put each of these products into registration mode. The range of all radio devices can be affected by the working environment, always take care during installation and perform several test calls. Important Note on Sensor Testing The gas and detector should be functionally tested every 6-12 months (depending on location). The gas sensor can only be tested with calibrated test gas, never test using neat gas as this will poison the sensor. The sensor can only be tested with calibrated test, this will take less than 1 minute to trigger. For test gas supplies please contact Duomo. In Case of Gas Alarm If gas is detected the RED ALARM light will illuminate, and the audible alarm will sound. Put out all naked flames. Don t smoke. Don t use naked flames. Don t turn electrical switches on or off. Turn the gas off at the supply. Open windows and doors to ventilate the area. The alarm will silence when the gas is cleared. If the alarm continues to sound and the leak cannot be found, vacate the premises and inform the Gas Emergency Service immediately. In Case of Carbon Monoxide Alarm If carbon monoxide is detected the RED ALARM light will illuminate, and the audible alarm will sound. Open windows and doors to ventilate the area. If the alarm stops it is safe for a qualified person to find the cause of the alarm. If the alarm continues turn the appliance off and do not use until it has been checked by a qualified person. Get medical help for anyone suffering headaches or nausea, advise that carbon monoxide poisoning is suspected. In Case of Fault If the YELLOW FAULT light illuminates the self test feature has detected a fault with the sensor. The unit is probably defective and must be replaced. After 6 years the YELLOW light will blink continuously, and the unit will emit a beep every hour. The sensor has exceeded its useful life and must be replaced. False Alarms It is possible aerosol sprays, alcohol used in cooking, cigarette, cigar or pipe smoke, gas from a cigarette lighter, strong household cleaning agents, polishes or solvents may cause false alarms. Cleaning and Care It is recommended to clean the gas & detector periodically using the nozzle attachment on a vacuum cleaner to remove dust, insects and cobwebs from the cover slots. The detector can be wiped clean with a damp cloth, never use detergents or polish etc. Avoid spraying any aerosols near the detector. Decorating Never paint the gas & detector itself. Unplug the mains supply and cover the detector when decorating to avoid contamination from water or dust. Battery Life The transmitter battery is checked once a day, if the voltage falls and stays below a preset level for 7 consecutive days a low battery alert is automatically transmitted. Once a low battery call is received the gas & detector should be replaced within 7 days. The gas & detector must be returned to Tynetec/Aidcall for battery replacement. Detailed information on battery management for all Tynetec/Aidcall products is available - request Doc No. FM0630. Doc No. FM0471 issue G Page 2

Registering a Gas & Detector onto a Reach at-home alarm unit 1. Put the Reach unit into radio device learn mode Trigger Radio Device Press and HOLD the GREEN button on the Reach unit. When the front light FLASHES FAST GREEN release the button and the Reach will announce Trigger Radio Device. You now have 1 minute to activate the gas & detector. 2. Activate the gas & detector Press the button once and the Reach will announce Gas. Wait for about 10 seconds then Press the button once and the Reach will announce Carbon Monoxide. 3. Exit radio device learn mode Press the GREEN button on the Reach unit. The front light will return to STEADY GREEN and the Reach is back in normal operating mode. 4. Check with the Control Centre that it is convenient to perform a test call, first activate a gas test call and confirm they receive a gas alarm call, then activate a test call and confirm they receive a carbon monoxide alarm call. Deleting a Gas & Detector from a Reach at-home alarm unit Enter 1 6 7 0 using the keypad on the rear of the Reach unit the front light will FLASH FAST GREEN and the unit will announce Program Mode - Ready. Enter # 0 4 1 and the Reach will announce Delete Radio Device followed by a Beep. Enter the 8 digit gas detector ID to be deleted and wait for the Beep Enter the 8 digit detector ID to be deleted, after the Beep press # to exit. Press the key to exit Program Mode; the unit will sound a Double-Beep and the front light will return to STEADY GREEN. Both 8 digit ID s can be found on a label on the back of the gas & detector they will always start with 44xxxxxx and 49xxxxxx. The instructions given above for the standard Reach product also applies to the Reach Plus, Reach Plus GSM and Reach Ultra models. Refer to the instruction booklets provided with these products for more information on programming and testing radio devices. Doc No. FM0471 issue G Page 3

Registering a Gas & Detector onto an Advent xt warden call system 1. Put the Advent xt system into radio device learn mode Ready Using the Manager s DECT telephone; Press the LINE key and wait for the Ready prompt. Enter 5 0 0 0 followed by the key. Enter the flat number the gas & detector is being installed in followed by the key. You now have 1 minute to activate the gas & detector. 2. Activate the gas & detector Press the button once. Wait for the Enter Location Code prompt then press 0 (no location) followed by the key. Wait for the Pendant Enabled Enter Flat prompt. Press the button once. Wait for the Enter Location Code prompt then press 0 (no location) followed by the key. Wait for the Pendant Enabled Enter Flat prompt. 3. Exit the Advent xt system radio device learn mode Ready Using the Manager s DECT telephone; Press the # key and wait for the Ready prompt. Press the LINE key to clear the connection and the warden call system is now back in normal operating mode. 4. First activate a gas test call and check a gas alarm call is reported on the warden call system, then activate a test call and check a carbon monoxide alarm call is reported. Deleting a Gas & Detector from an Advent xt warden call system Press the LINE key and wait for the Ready prompt. Enter 5 0 0 1 followed by the key. Enter the flat number the gas detector is being deleted from followed by the key. Press the button on the gas & detector to be deleted. Wait for the Pendant Disabled Enter Flat prompt. Press the button on the gas & detector to be deleted. Wait for the Pendant Disabled Enter Flat prompt. Press the # key and wait for the Ready prompt, then press the LINE key to clear the connection. Refer to the Advent xt operators manual (Doc No. FM0420) provided with the warden call system for more information on programming and testing radio devices. Doc No. FM0471 issue G Page 4

Registering a Gas & Detector onto an Altec Response local carer alarm unit 1. Put the Altec Response unit into radio device learn mode tynetec Press ENTER to activate the wake-up display then ENTER again to display the main menu. Press ENTER to select Radio Devices Press ENTER to select Learn Device The display will prompt you to Trigger the Sensor. You now have 20 seconds to activate the gas & detector. 2. Activate the gas & detector Press the button once. The display will show Gas Alarm and the gas detector 8 digit ID number. Check the ID is correct, press the key to select Accept then press ENTER. Note: if another device has been picked-up press ENTER to Reject and try again. The display will show Flat, use the & keys to choose the dwelling type. Press the key to select No: 000000 then press the ENTER key. Use the & keys to select each digit of the flat number and the & keys to move between digits then press the ENTER key. Press key several times to select Exit then press the ENTER key. The display will prompt you to Trigger the Sensor again. Press the button and repeat as above. 3. Exit the Altec Response radio device learn mode tynetec From the Learn Device menu select Exit then press ENTER. From the Radio Devices menu select Exit then press ENTER. The display will return to the wake-up screen and go blank after 10 seconds. The Altec Response is now back in normal operating mode. 4. Activate the gas detector and check a gas alarm call is displayed on the Altec Response unit. Deleting a Gas & Detector from an Altec Response local carer alarm unit Press ENTER to activate the wake-up display then ENTER again to display the main menu Press ENTER to select Radio Devices Press the key to select Delete Device then press ENTER The display will prompt you to Trigger the Sensor Press the button on the gas & detector to be deleted - the display will show the device type and its 8 digit ID If this is the device you activated press the key to select Delete then press ENTER Press the button on the gas & detector to be deleted - the display will show the device type and its 8 digit ID If this is the device you activated press the key to select Delete then press ENTER Note: if the ID is NOT the device you activated press the ENTER key to select Reject then try again To exit the mode select Exit then press the ENTER key. Refer to the Altec Response installation guide (Doc No. FM0548) provided with the portable alarm unit for more information on programming and testing radio devices. Doc No. FM0471 issue G Page 5

Registering a Gas & Detector onto a Touchsafe Pro Nursecall system 1. Put the Touchsafe Pro Master Panel into Telecare registration mode; touch the screen and Logon as an Engineer or a Manager (password required), then from the main menu page touch the Telecare button to open the screen shown below On-screen keypad Use keypad to enter 8 digit ID s* here Select the relevant Call Point ID here Close to exit mode Save when done *Note: both gas and ID s must be entered; Prefix 44 = Gas and Prefix 49 = 2. Enter the gas and detector ID s ZXT427 W66283 Ser: 10151313 ID: 44037640 MC ID: 49040302 EE0775 V1.01A Both 8 digit ID s are printed on a label on the rear of the gas & detector. Note: the ID s will always start with 44xxxxxx (gas) and 49xxxxxx (). Touch the Add Telecare Device box then use the on-screen keypad to enter the gas ID. Hint: enter a zone in the Filter box to narrow the search for the room (see below). Select the users Call Point ID from the Room pull-down list box then press Save. Note: this is the room unit that will be will be used to cancel the call. Touch the Add Telecare Device box again and repeat as above for the ID. 3. Press the Close button to exit Telecare mode and the Nursecall panel is now back in normal operating mode. 4. Activate both gas and test calls and check they are displayed on the Nursecall panel like this CALLING CANCEL HC 345 ID 001 The screen banner is red for a gas and alarm call (Touch the banner to display notes). A gas or alarm call cannot be accepted or silenced from the screen. You must visit the appropriate Nursecall Call Point to cancel the call. Press the LIGHT GREY button to cancel the call Deleting a Gas & Detector from a Touchsafe Pro Nursecall system Select the gas detector ID to be deleted from the Delete Telecare Device pull-down list box (prefixed T44 ). Details of the gas detector selected will be displayed in the Room, House Code and ID boxes below. If the details shown are correct press the Delete button. Select the detector ID to be deleted from the Delete Telecare Device pull-down list box (prefixed T49 ) and repeat as above. Press the Close button to exit. Refer to the Touchsafe Pro Display Panel user guide (Doc No. FM5505) provided with the Nursecall system for more information. Tynetec and Aidcall operate a policy of continuous improvement and reserve the right to change product specifications without notice. If any variation to the details contained in this document are suspected please contact Tynetec s customer support dept on 01670 352371. Doc No. FM0471 issue G Page 6