PRODUCT GUIDE & INFORMATION. Professional Fire & Carbon Monoxide Solutions
|
|
- Blaze Harvey
- 6 years ago
- Views:
Transcription
1 PRODUCT GUIDE & INFORMATION Professional Fire & Carbon Monoxide Solutions 1
2 Nearly 50 years experience of designing, manufacturing and supplying home safety products, makes BRK an industry leader. We believe it is our responsibility to provide superior performing products at cost effective prices; with ranges designed for professionals, by professionals. 2
3 Contents BRK Product Guide BRK Introduction 2 Contents 3 700MRL Series Range Pages MBX Series Range Pages 6-7 Product Range MRL/MBX Mains Powered Smoke Alarm MRL/MBX Mains Powered Mains Smoke Alarm MRL/MBX Mains Powered Mains Heat Alarm DS700RF Wireless Interlink Base RF Base 14 CO850MRLi/MBXi Mains Powered Carbon Monoxide Alarm 15 CO850MRLi/MBXi Mains Powered Carbon Monoxide Alarm Product Specification 16 General Guidance Siting of Smoke Alarms 18 Siting of Heat Alarms 19 Siting of Carbon Monoxide Alarms 20 System Grades & Categories Explained 21 Minimum Grade & Category of Detection 22 Notes 23 3
4 700MRL Series Mains powered alarms with rechargeable Lithium battery back-up MRL BACK-UP Long life rechargeable lithium battery removes the need to replace the batteries THERMALLY ENHANCED OPTICAL 760MRL Thermally enhanced optical sensor for fast detection of all fire types Supplied with PUSH-FIT base Hardwire interconnect with up to 12 units See page 8-9 EN14604:2005 Licence No: 14LHK CPR EN14604: 2005 DoP: 14/11 IONISATION SMOKE 770MRL Dual ionisation sensing chamber Supplied with PUSH-FIT base Hardwire interconnect with up to 12 units See page BSEN14604:2005 Licence No: KM CPR EN14604: 2005 DoP 13/05 HEAT 790MRL Advanced Class A2 thermistor Supplied with PUSH-FIT base Hardwire interconnect with up to 12 units See page BS5446-2:20035 Licence No: 14LHK0079 4
5 WIRELESS INTERLINK BASE DS700RF RF base provides a wireless interlink between mains powered smoke and heat alarms in the 700 series Quick to install and quick to link Interlink up to 50 smoke and heat alarms See page 14 CARBON MONOXIDE CO850MRLi Advanced electrochemical sensor Mains powered with battery back-up Hardwire interconnect with up to 12 CO alarms See page 15 BSEN :2010 Licence No: KM
6 700MBX Series Mains powered alarms with Alkaline battery back-up MBX BACK-UP 9V alkaline battery is ideal where cost saving is a priority THERMALLY ENHANCED OPTICAL 760MBX Thermally enhanced optical sensor for fast detection of all fire types Supplied with PUSH-FIT base Hardwire interconnect with up to 12 units See page 8-9 EN14604:2005 Licence No: 14LHK CPR EN14604: 2005 DoP: 14/11 IONISATION SMOKE 770MBX Dual ionisation sensing chamber Supplied with PUSH-FIT base Hardwire interconnect with up to 12 units See page BSEN14604:2005 Licence No: KM CPR EN14604: 2005 DoP 13/05 HEAT 790MBX Advanced Class A2 thermistor Supplied with PUSH-FIT base Hardwire interconnect with up to 12 units See page BS5446-2:20035 Licence No: 14LHK0079 6
7 WIRELESS INTERLINK BASE DS700RF RF base provides a wireless interlink between mains powered smoke and heat alarms in the 700 series Quick to install and quick to link Interlink up to 50 smoke and heat alarms See page 14 CARBON MONOXIDE CO850MBXi Advanced electrochemical sensor Mains powered with battery back-up Hardwire interconnect with up to 12 CO alarms See page 15 BSEN :2010 Licence No: KM
8 760MRL & 760MBX Mains Powered Smoke Alarm Grade Sensor type Battery back-up type Key Features D - Mains Powered with battery back-up Thermally enhanced optical MRL - Rechargeable lithium / MBX - 9V alkaline Thermally enhanced optical sensing technology for fast detection of all fire types. 230V mains powered. Battery back-up: MRL - 10 year sealed for life rechargeable lithium battery. MBX- 9V alkaline battery. Hardwire interconnect with up to 12 smoke/heat alarms. Compatible with DS700RF wireless interlink base. Supplied with PUSH-FIT base. Central test and silence button. Technical Specification EN14604:2005 Licence No: 14LHK CPR EN14604: 2005 DoP: 14/11 140mm 53mm 140mm 53mm Dimensions 8 140mm (diameter) x 53mm (depth) 140mm (diameter) x 53mm (depth) Product Code 760 MRL 760 MBX Supply voltage 230V AC, 50Hz 230V AC, 50Hz Battery back-up Rechargeable lithium battery 9V alkaline battery Technology Thermally enhanced optical Thermally enhanced optical Alarm sound level 85dB(A) at 3m (minimum) 85dB(A) at 3m (minimum) Installation positions Ceiling / Wall Ceiling / Wall Operating temperature +5 C to +38 C +5 C to +38 C Operating humidity 10% to 85% relative 10% to 85% relative Storage temperature +5 C to +38 C +5 C to +38 C Storage humidity 10% to 85% relative 10% to 85% relative Plastic material ABS, UL94 VO fire retardant ABS, UL94 VO fire retardant Warranty 5 years 5 years Master pack quantity Weight 340g 377g Certified to BS EN 14604: 2005 BS EN 14604: 2005 Independently tested to N/A N/A Maximum number of connected units 12 hardwired units 12 hardwired units Operating Frequency N/A N/A Range N/A N/A
9 Product Specification The smoke alarm shall carry the BSI Kitemark to indicate type testing to BS EN14604: 2005 and will meet the requirements of Grade D as defined in BS 5839 Pt.6: The alarm shall carry the CE mark to indicate conformance to all of the applicable EC directives including Low Voltage and Electromagnetic Compatibility Directives. The alarm shall utilise thermally enhanced optical technology which incorporates an optical sensing chamber and thermal enhancement components which make adjustments to the sensitivity settings of the alarm dependent upon background temperature. Providing a quicker response time to both slow smouldering, and fast flaming fires. MRL The alarm shall operate on a 230V mains power supply and have a built-in, sealed for life, rechargeable lithium battery back-up to power the alarm in the event of a mains failure. MBX - The alarm shall operate on a 230V mains power supply and shall be supplied with 9V PP3 alkaline battery back-up to power the alarm in the event of a mains failure. The alarm is supplied with a PUSH-FIT mounting base for ease of installation. The alarm shall automatically connect to the mains as it locks onto the mounting base without the need to use a separate wired connector. The alarm shall disconnect from the mains supply as it s removed from the mounting base with the use of a tool. The alarm shall have the ability to hardwire or interconnect with up to 12 other smoke or heat alarms of a similar type on a single network. The alarm shall have wireless interconnect capability with the DS700RF wireless interlink base, allowing up to 50 alarms of a similar type to be wirelessly interlinked on a single network. The alarm shall have a green LED mains indicator to confirm mains power supply is on. The alarm shall have a separate red LED that will flash approximately every 45 seconds to confirm circuitry integrity. The alarm shall have an integral test / silence button in order to test circuitry, sensor and sounder and activate all interconnected alarms in the system. The alarm shall have a silence feature which allows the alarm to be silenced for up to 10 minutes in the event of a known false alarm. A red LED shall flash every 10 seconds to indicate that the alarm is in silence mode and will automatically reset after approximately 10 minutes. The alarm shall have a low battery warning signal, which will chirp approximately every 45 seconds. This will continue until the alarm which has the low battery condition is removed. The alarm shall be supplied with a dust cover that can be fitted to protect it from contamination during installation. The alarm has a built in sounder giving a minimum sound output of 85dB(A) at 3m. The alarm shall be supplied with installation / user instructions. The alarm and base shall have the following combined dimensions: 140mm dia. x 53mm depth. MRL - The alarm and base shall have the following combined weight: 304g. MBX - The alarm and base shall have the following combined weight: 332g. The alarm shall have a 5 year warranty. Key Technology PUSH-FIT base Two sensors provide heat readings, to enable early warning of fire Test and alarm silence button MRL - Rechargeable lithium battery back-up MBX - 9V alkaline battery back-up Thermally enhanced optical sensing chamber 9
10 770MRL & 770MBX Mains Powered Smoke Alarm Grade Sensor type Battery back-up type Key Features D - Mains powered with battery back-up Ionisation MRL - Rechargeable lithium / MBX - 9V alkaline Ionisation sensing technology. 230V mains powered. Battery back-up: MRL - 10 year sealed for life rechargeable lithium battery. MBX- 9V alkaline battery. Hardwire interconnect with up to 12 smoke/heat alarms. Compatible with DS700RF wireless interlink base. Supplied with PUSH-FIT base. Central test and silence button. Technical Specification BSEN14604:2005 Licence No: KM CPR EN14604: 2005 DoP 13/05 140mm 53mm 140mm 53mm Dimensions mm (diameter) x 53mm (depth) 140mm (diameter) x 53mm (depth) Product Code 770 MRL 770 MBX Supply voltage 230V AC, 50Hz 230V AC, 50Hz Battery back-up Rechargeable lithium battery 9V alkaline battery Technology Ionisation Ionisation Alarm sound level 85dB(A) at 3m (minimum) 85dB(A) at 3m (minimum) Installation positions Ceiling / Wall Ceiling / Wall Operating temperature +5 C to +38 C +5 C to +38 C Operating humidity 10% to 85% relative 10% to 85% relative Storage temperature +5 C to +38 C +5 C to +38 C Storage humidity 10% to 85% relative 10% to 85% relative Plastic material ABS, UL94 VO fire retardant ABS, UL94 VO fire retardant Warranty 5 years 5 years Master pack quantity Weight 262g 316g Certified to BS EN 14604: 2005 BS EN 14604: 2005 Independently tested to N/A N/A Maximum number of connected units 12 hardwired units 12 hardwired units Operating Frequency N/A N/A Range N/A N/A
11 Product Specification The smoke alarm shall carry the BSI Kitemark to indicate type testing to BS EN14604: 2005 and will meet the requirements of Grade D as defined in BS 5839 Pt.6: The alarm shall carry the CE mark to indicate conformance to all of the applicable EC directives including Low Voltage and Electromagnetic Compatibility Directives. The alarm shall have a dual ionisation chamber sensor, with corrosion resistant electrodes and an insect resistant cover. MRL - The alarm shall operate on a 230V mains power supply and shall be supplied with a built-in, sealed for life, rechargeable lithium battery back-up to power the alarm in the event of a mains failure. MBX - The alarm shall operate on a 230V mains power supply and shall be supplied with 9V PP3 alkaline battery back-up to power the alarm in the event of a mains failure. The alarm is supplied with a PUSH-FIT mounting base for ease of installation. The alarm shall automatically connect to the mains as it lock onto the mounting base without the need to use a separate wired connector. The alarm shall disconnect from the mains supply as it s removed from the mounting base with the use of a tool. The alarm shall have the ability to hardwire or interconnect with up to 12 other smoke and heat alarms of a similar type on a single network. The alarm shall have wireless interconnect capability with the DS700RF wireless interlink base, increasing the number of connected alarms to a maximum of 50. The alarm shall have a green LED mains indicator to confirm mains power supply is on. The alarm shall have a separate red LED that will flash approximately every 45 seconds to confirm circuitry integrity. The alarm shall have an integral test / silence button in order to test circuitry, sensor and sounder and activate all interconnected alarms in the system. The alarm shall have a silence feature which allows the alarm to be silenced for up to 10 minutes in the event of a known false alarm. A red LED shall flash every 10 seconds to indicate that the alarm is in silence mode and will automatically reset after approximately 10 minutes. The alarm shall have a low battery warning signal, which will chirp approximately every 45 seconds. This will continue until the alarm which has the low battery condition is removed. The alarm shall be supplied with a dust cover fitted to protect it from contamination during installation. The alarm has a built in sounder giving a minimum sound output of 85dB(A) at 3m. The alarm shall be supplied with installation / user instructions. The alarm and base shall have the following combined dimensions: 140mm dia. x 53mm depth. MRL The alarm and base shall have the following combined weight: 262g. MBX - The alarm and base shall have the following combined weight: 316g. Key Technology PUSH-FIT base Test and alarm silence button MRL - Rechargeable lithium battery back-up MBX - 9V alkaline battery back-up Dual ionisation chamber 11
12 790MRL & 790MBX Mains Powered Heat Alarm Grade Sensor type Battery back-up type Key Features D - Mains powered with battery back-up Thermistor MRL - Rechargeable lithium / MBX - 9V alkaline Advanced Class A2 thermistor sensing technology. 230V mains powered. Battery back-up: MRL - 10 year sealed for life rechargeable lithium battery. MBX- 9V alkaline battery. Hardwire interconnect with up to 12 smoke/heat alarms. Compatible with DS700RF wireless interlink base. Supplied with PUSH-FIT base. Central test and silence button. Technical Specification BS5446-2:20035 Licence No: 14LHK mm 68mm 140mm 68mm Dimensions mm (diameter) x 68mm (depth) 140mm (diameter) x 68mm (depth) Product Code 790 MRL 790 MBX Supply voltage 230V AC, 50Hz 230V AC, 50Hz Battery back-up Rechargeable lithium battery 9V alkaline battery Technology Advanced Thermistor Advanced Thermistor Alarm sound level 85dB(A) at 3m (minimum) 85dB(A) at 3m (minimum) Installation positions Ceiling Ceiling Alarms at temperature range +54 C to +70 C +54 C to +70 C Operating temperature +5 C to +38 C +5 C to +38 C Operating humidity 10% to 85% relative 10% to 85% relative Storage temperature +5 C to +38 C +5 C to +38 C Storage humidity 10% to 85% relative 10% to 85% relative Plastic material ABS, UL94 VO fire retardant ABS, UL94 VO fire retardant Warranty 5 years 5 years Master pack quantity Weight 340g 377g Certified to BS : 2003 BS : 2003 Independently tested to N/A N/A Maximum number of connected units 12 hardwired units 12 hardwired units Operating Frequency N/A N/A Range N/A N/A
13 Product Specification The heat alarm shall carry the BSI Kitemark to indicate type testing to BS : It will meet the requirements of Grade D as defined in BS 5839 Pt.6: 2013 for a Class A2 device. The alarm shall carry the CE mark to indicate conformance to all of the applicable EC directives including; Low Voltage and Electromagnetic Compatibility Directives. The alarm shall be a fixed point heat alarm, with a temperature range of 54 C to 70 C. MRL The alarm shall operate on a 230V mains power supply and have a built-in, sealed for life, rechargeable lithium battery back-up to power the alarm in the event of a mains failure. MBX The alarm shall operate on a 230V mains power supply and shall be supplied with 9V PP3 alkaline battery back-up to power the alarm in the event of a mains failure. The alarm is supplied with a PUSH-FIT mounting base for ease of installation. The alarm shall automatically connect to the mains as it locks onto the mounting base without the need to use a separate wired connector. The alarm shall disconnect from the mains supply as it s removed from the mounting base with the use of a tool. The alarm shall have the ability to hardwire or interconnect with up to 12 other smoke and heat alarms of a similar type on a single network. The alarm shall have wireless interconnect capability with the DS700RF wireless interlink base, allowing up to 50 alarms of a similar type to be wirelessly interlinked on a single network. The alarm shall have a green LED mains indicator to confirm mains power supply is on. The alarm shall have a separate red LED that will flash approximately every 45 seconds to confirm circuitry integrity. The alarm shall have an integral test / silence button in order to test circuitry, sensor and sounder and activate all interconnected alarms in the system. The alarm shall have a silence feature which allows the alarm to be silenced for up to 10 minutes in the event of a known false alarm. A red LED shall flash every 10 seconds to indicate that the alarm is in silence mode and will automatically reset after approximately 10 minutes. The alarm shall have a low battery warning signal, which will chirp approximately every 45 seconds. This will continue until the alarm which has the low battery condition is removed. The alarm shall be supplied with a dust cover that can be fitted to protect it from contamination during installation. The alarm has a built in sounder giving a minimum sound output of 85dB(A) at 3m. The alarm shall be supplied with installation / user instructions. The alarm and base shall have the following combined dimensions: 140mm dia. x 68mm depth. MRL The alarm and base shall have the following combined weight: 286g. MBX The alarm and base shall have the following combined weight: 304g. The alarm shall have a 5 year warranty. Key Technology PUSH-FIT base Central test button and robust sensor shield MRL - Rechargeable lithium battery back-up High performance thermistor MBX - 9V alkaline battery back-up 13
14 DS700RF Wireless Interlink Base Key Features 10 year sealed for life lithium battery. PUSH-FIT base. Automatic ID coding. Wirelessly interlink up to 50 smoke and heat alarms of a similar type. Base has both side and rear entry knock outs Visual LED and audible fault warnings. 5 year guarantee. Technical Specification 140mm 30mm Dimensions 140mm (diameter) x 30mm (depth) 14 Supply voltage 3V DC Battery back-up 10 year sealed for life lithium battery Technology Wireless technology Alarm sound level N/A Installation positions Ceiling / Wall Operating temperature +5 C to +38 C Operating humidity 10% to 85% RH non-condensing Storage temperature -20 C to 60 C Storage humidity 10% to 85% RH non condensing Plastic material ABS, UL94 VO fire retardant Warranty 5 years Master pack quantity 10 Weight 145g Certified to N/A Independently tested to ETSI EN V2.3.2 ( ), EN &-3, EN , EN60065 Maximum number of connected units 50 wireless units Operating Frequency 868 MHz Range 35m (over 200m in clear air)
15 CO850 (MRLi/ MBXi) Mains Powered CO Alarm Sensor type Battery back-up type Key Features Electrochemical MRLi - Rechargeable lithium / MBXi - 9V alkaline Advanced electrochemical sensor - calibrated and tested in CO gas. 230V mains powered. Battery back-up: MRL - 10 year sealed for life rechargeable lithium battery. MBX- 9V alkaline battery. Hardwire interconnect with up to 12 units of a similar type. Power, alarm and fault indicators. Instant test / reset feature. BSEN :2010 Licence No: KM Technical Specification 69mm 60mm 69mm 60mm Dimensions 134mm (height) x 69mm (width) x 60mm (depth) 134mm 134mm (height) x 69mm (width) x 60mm (depth) 134mm Product code CO850 MRLi CO850 MBXi Supply voltage 230V AC, 50Hz 230V AC, 50Hz Battery back-up Rechargeable lithium battery 9V alkaline battery Technology Electrochemical Electrochemical Alarm sound level 85dB(A) at 1m (minimum) 85dB(A) at 1m (minimum) Installation positions Wall Wall Operating temperature -10 C to +40 C -10 C to +40 C Operating humidity 30% to 90% RH non-condensing 30% to 90% RH non-condensing Storage temperature 0 C to +40 C 0 C to +40 C Storage humidity 30% to 90% RH non-condensing 30% to 90% RH non-condensing Plastic material ABS, UL94 VO fire retardant ABS, UL94 VO fire retardant Warranty 5 years 5 years Master pack quantity Weight 226g 226g Certified to BS EN :2010 BS EN :2010 Independently tested to N/A N/A Maximum number of connected units 12 hardwired units 12 hardwired units Operating Frequency N/A N/A Range N/A N/A 15
16 CO Alarm Product Specification CO850 (MRLi/MBXi) The carbon monoxide alarm shall carry the BSI Kitemark to indicate type testing to BS EN : The alarm shall carry the CE mark to indicate conformance to all of the applicable EC directives including Low Voltage and Electromagnetic Compatibility Directives. The alarm shall have an advanced electrochemical sensor. Each sensor shall be calibrated and tested in CO gas to ensure accuracy. The alarm shall operate on a 230V mains power supply with a battery back-up. CO850MRLi- The alarm shall operate on a 230V mains power supply and have a built-in, sealed for life, rechargeable lithium battery back-up to power the alarm in the event of a mains failure. CO850MBXi- The alarm shall operate on a 230V mains power supply and shall be supplied with 9V PP3 alkaline battery back-up to power the alarm in the event of a mains failure. The alarm shall have the ability to hardwire interconnect with up to 12 CO alarms of a similar type on a single network. The alarm shall have a green LED mains indicator to confirm mains power supply is on. In the event of a mains failure the green LED will flash approximately once every 60 seconds, to indicate that the back-up battery is in use. The alarm shall have a low battery warning signal, which will chirp approximately once every 60 seconds. A yellow LED shall also flash approximately once every 60 seconds. The alarm shall have a fault warning, which will emit 2 short chirps approximately once every 60 seconds. A yellow LED shall also light up and remain lit. The alarm shall have an end of life warning, which will emit 3 short chirps approximately once every 60 seconds. The alarm shall have an integral test / reset button in order to test circuitry, sensor and sounder and activate all interconnected alarms in the system. The alarm has a built in sounder giving a minimum sound output of 85dB(A) at 1m. The alarm shall be supplied with installation / user instructions. The alarm and base shall have the following combined dimensions: 134mm height x 69 width x 71mm depth. The alarm and base shall have the following combined weight: 262g. The alarm shall have a 5 year warranty. 16
17 General Guidance 17
18 Siting of Smoke Alarms* Flat ceiling Site at least from walls. Site at least from any light fittings. Site as centrally as possible. Flat ceilings with beams Site at least twice the depth of the beam away e.g. 150mm beam depth: site the alarm at least away from the beam. 150mm If depth of beam is greater than 10% of the ceiling height, the beam should be treated as a wall (alarms need to be on either side of the beam). >10% ceiling height Pitched roof Site at no more than 600mm vertically below apex. 600mm Wall mounted The top of the detection element is between 150mm and below the ceiling. Site at least from a perpendicular wall * For full guidance on what type of alarm to install and where consult BS 5839 Pt.6:
19 Siting of Heat Alarms* Flat ceiling Site at least from walls. Site at least from any light fittings. Site as centrally as possible. Flat ceilings with beams Site at least twice the depth of the beam away e.g. 150mm beam depth: site the alarm at least away from the beam. 150mm If depth of beam is greater than 10% of the ceiling height, the beam should be treated as a wall (alarms need to be on either side of the beam). >10% ceiling height Pitched roof Site at no more than 600mm vertically below apex. 600mm * For full guidance on what type of alarm to install and where consult BS 5839 Pt.6:
20 Siting of CO Alarms* When installing a CO alarm in a room where there is an appliance fitted Ceiling mounted Site at least from walls. Site at least from any light fittings. Site between 1 to 3 metres from the fuel burning appliance. 1-3m If the room has a partition, site the alarm on the side of the appliance. Wall mounted in a bedroom Site close to the ceiling but at least 150mm down. 1-3m 150mm Site at least from a perpendicular wall. Site between 1 to 3 metres from the fuel burning appliance. When installing a CO alarm in a room where there is no appliance fitted Wall mounted Site at the breathing height of the occupants (bed height). Site at the breathing height of the occupants (seated height). 20 * The guidance is taken from BS , for further advice please refer to the standard.
21 BS 5839 Pt. 6: System Grades & Categories System Grades GRADE A A fire detection and fire alarm system which incorporates control and indicating equipment installed to BS 5839: Part 1. GRADE B A fire detection and fire alarm system comprising of fire detectors other than smoke alarms and heat alarms, fire alarm sounders and control and indicating equipment. GRADE C A system of fire detection and alarm sounders (which may be combined in the form of smoke alarms) connected to a common mains power supply with back-up and indicating equipment. GRADE D Mains powered alarms with an integral stand-by power supply(battery back up). GRADE E Mains powered alarms with no stand-by power supply. GRADE F Battery powered alarms. Categories LD1 MAXIMUM PROTECTION Alarms in all circulation spaces that form part of escape routes and all areas where a fire might start, but not bathrooms, shower rooms or toilets. LD2 ADDITIONAL PROTECTION In all circulation spaces that form part of escape routes and rooms or areas that present a high fire risk. LD3 MINIMUM PROTECTION Alarms in all circulation spaces that form part of escape routes. 21
22 Minimum Grade and Category of Detection* BS 5839 Pt.6:2013 Fire detection and fire alarm system for protection of life in typical premises Class of premises New or materially altered premises conforming to guidance that supports national building regulations Existing premises conforming to current guidance that supports national building regulations Existing premises where structural fire precautions are of a lower standard than those recommended in current guidance that supports national building regulations Grade Category Grade Category Grade Category Single-family dwellings and shared houses with no floor greater than 200m 2 in area Owner-occupied bungalow, flat or other single-storey unit Rented bungalow, flat or other single-storey unit Owner-occupied maisonette, or owner-occupied two-story house Rented maisonette or rented two-storey house D LD2 F LD3 D LD2 D LD2 D LD3 D LD2 D LD2 F LD3 D LD2 D LD2 D LD3 D LD2 Three-storey house D LD2 D LD3 D LD2 Four (or more) storey house A LD2 D LD2 A LD2 Single-family dwellings and shared houses with one or more floors greater than 200m 2 in area Bungalow, flat or other single-storey unit D LD2 D LD3 D LD2 Maisonette or two-storey house A LD2 A LD2 A LD2 Three (or more) storey house Grade A, Category LD2, with detectors sited in accordance with the recommendations of BS for Category L2 system Houses in multiple occupation HMOs of one or two-storeys with no floor greater than 200m 2 in area Other HMOs: Individual dwelling units, within the HMO, comprising two or more rooms Communal areas of the HMO D LD2 D LD3 D LD2 D LD2 D LD3 D LD2 Grade A, Category LD2, with detectors sited in accordance with the recommendations of BS for Category L2 system Sheltered housing Individual dwelling units Communal area D LD2 D LD3 D LD2 Housing provided NHS supported living in the community All premises Grade A, Category LD1, with detectors sited in accordance with the recommendations of BS for Category L1 system 22 *The above guidance is taken from BS 5839 Pt.6: 2013, for further advice please refer to the standard. However other relevant standards and guidance exist, for example the Local Authority Co-ordinators of Regulatory Services (LACoRS).
23 Notes 23
24 HEAD OFFICE Sprue Safety Products Ltd. Vanguard Centre, Sir William Lyons Road, Coventry, CV4 7EZ UK. TRADE SALES Sprue Safety Products Ltd. Unit 6, Carter Court, Davy Way, Waterwells Business Park, Quedgeley, Gloucester, GL2 2DE UK. MAIN SWITCHBOARD CUSTOMER SERVICE / TECHNICAL ENQUIRIES brk.co.uk GN3770/R2 24
Datasheet for Models: 1SFWR 1SFW. NEW range. capability. 230V Mains Fast-Fit Ionisation Smoke Alarms. Key Features. Applications
Datasheet for Models: 1SFWR 1SFW NEW range Developed specifically for social and private housing, Slick is the only range of fast-fit rechargeable ionisation and optical smoke alarms, and heat alarms guaranteed
More informationUSER MANUAL 10 YEAR LIFE SMOKE ALARM
USER MANUAL 10 YEAR LIFE SMOKE ALARM 17 0086 EN 14604:2005+AC: 2008 Smoke alarm devices DOP: SADOPST-750-01 BS EN 14604: 2005+AC: 2008 Licence No: KM557789 GN4681R1 ST-750 Sprue Safety Products Ltd. Vanguard
More informationWireless Interlink Smoke Alarm + 10 Year Life
User Manual Wireless Interlink Smoke Alarm + 10 Year Life WST-630 Please retain this user manual for future reference 1 CONTENTS Introduction 3 Sensor technology 3 Application 3 Positioning 4 How to install
More informationSpecification and Electrical Contractor Guide
Specification and Electrical Contractor Guide Driven by passionate people and a common goal to save lives! Europe s leading provider of domestic safety products. Our comprehensive range of products offer
More informationB16008-R0-160RC SERIES-U&C 17/1/07 11:13 AM Page Installation Guide
B16008-R0-160RC SERIES-U&C 17/1/07 11:13 AM Page 1 1.1 Installation Guide 2 SCREWDRIVER INTO S & PUSH COVER AWAY B16008-R0-160RC SERIES-U&C 17/1/07 11:13 AM Page 2 2. ALARM REMOVAL LOCATE REMOVAL SLOT
More informationBristol City Council Private Rented Sector Fire Safety Standards
Bristol City Council Private Rented Sector Fire Safety Standards Introduction The purpose of this document is to provide a basic guide to the fire precautions that are required in privately rented properties
More informationEurope s Leading Manufacturer of Fire + Carbon Monoxide Alarms
Europe s Leading Manufacturer of Fire + Carbon Monoxide Alarms Need more info? Call us on +353 (0)61 471277 Ei Electronics e-mail: sales@eielectronics.ie web:www.eielectronics.com Ei Electronics, is an
More informationUBS1RF OPTICAL SMOKE ALARM EN 14604:2005/AC:2008 DOP:UBS1RF-001-V1
U S E R M A N U A L UBS1RF OPTICAL SMOKE ALARM EN 14604:2005/AC:2008 DOP:UBS1RF-001-V1 0359 18 UBS1RF Optical Smoke Alarm OverView This optical smoke alarm is a fire detection and alarm device which gives
More informationfrom the world leaders manufacturing over 35 million smoke, heat and carbon monoxide alarms every year
Cl/SfB (68.52) Uniclass L7625 September 2012 A UTC Fire & Security Company Your one-stop solution for hard-wired and sealed-in battery smoke and CO alarms from the world leaders manufacturing over 35 million
More informationEi160e Series 230V~ SMOKE & HEAT ALARMS. with Rechargeable Battery Backup. Instruction Manual. User Section
Ei160e Series 230V~ SMOKE & HEAT ALARMS with Rechargeable Battery Backup Instruction Manual User Section Introduction to Ei160e Smoke/Heat Alarms The Ei160e series is supplied with an Easi-Fit base that
More informationWIRELESS INTERLINK SMOKE ALARM + 10 YEAR LIFE WST-630
User Manual WIRELESS INTERLINK SMOKE ALARM + 10 YEAR LIFE WST-630 Please read me as I could save your life. Please retain this user manual for future reference Are you protected from deadly carbon monoxide?
More informationCOMBINED STROBE & VIBRATING PAD
User Manual COMBINED STROBE & VIBRATING PAD W2-SVP-630L BS 5446-3: 2005 Licence No: KM594270 W2-SVP-630L GN3621R1 A Sprue Safety Products Brand Sprue Safety Products Ltd. Vanguard Centre, Sir William Lyons
More information230V~ SMOKE & HEAT ALARMS. with Rechargeable Battery Backup. Instruction Manual. Contact Us
Ei160e Series 230V~ SMOKE & HEAT ALARMS with Rechargeable Battery Backup Instruction Manual Contact Us Aico Ltd Mile End Business Park, Maesbury Rd, Oswestry, Shropshire SY10 8NN, U.K. Tel: 01691 664100
More informationFIRE ALARMS. IN DWELLINGS By John Ware FIRE ALARMS
WM_Winter 05_part1_EW.qxd 17/11/05 6:55 am Page 1 1 IN DWELLINGS By John Ware IN THE UK around 80% of all fire deaths and injuries occur in dwellings, a total of 450 to 500 deaths and 14,000 injuries per
More information10 YEAR LIFE SMOKE ALARM 10 YEAR LIFE TOAST PROOF SMOKE ALARM
User Manual 10 YEAR LIFE SMOKE ALARM SI-610 10 YEAR LIFE TOAST PROOF SMOKE ALARM SO-610 Please read me as I could save your life. Please retain this user manual for future reference CONTENTS INTRODUCTION
More informationESCAPE LIGHT SMOKE ALARM LSI-601 ESCAPE LIGHT TOAST PROOF SMOKE ALARM LSO-601
User Manual ESCAPE LIGHT SMOKE ALARM LSI-601 ESCAPE LIGHT TOAST PROOF SMOKE ALARM LSO-601 Please read me as I could save your life. Please retain this user manual for future reference INTRODUCTION CONTENTS
More information230V~ MULTI-SENSOR FIRE ALARM. with Rechargeable Lithium Cell Back-up. P/N B18397 Rev2. Ei2110e Series. Instruction Manual.
230V~ MULTI-SENSOR FIRE ALARM with Rechargeable Lithium Cell Back-up P/N B18397 Rev2 Ei2110e Series Instruction Manual INSTALLER Section CONTENTS 1. QUICK GUIDE 1.1 INSTALLATION GUIDE 1.2 ALARM REMOVAL
More informationInstallation and User Guide
Installation and User Guide Carbon Monoxide Alarm 10 Year Life Model W2-CO-10X EN 50291-1:2010 EN 50291-2:2010 KM 551504 GN3231R3 W2-CO-10X Carbon Monoxide Alarm W2 module contained within product independently
More informationEi3024 / 3016 / 3014 Alarms Instruction Manual
Mains Powered Ei3024 / 3016 / 3014 Alarms Instruction Manual Read and retain carefully for as long as the product is being used. It contains vital information on the operation and installation of your
More informationFire Alarm Systems Design. incorporating Amendment No.2. a guide to BS5839. Part1:2002
a guide to Fire Alarm Systems Design BS5839 Part1:2002 incorporating Amendment No.2 The Regulatory Reform (Fire Safety) Order (RRO) became law on 1 October 2006 Legally you must comply! What is the RRO?
More informationLOW FREQUENCY SOUNDER
User Manual LOW FREQUENCY SOUNDER W2-LFS-630 Keeping the hard of hearing and high risk safe from fire and carbon monoxide For a full range of carbon monoxide alarms visit www.fireangel.co.uk CONTENTS INTRODUCTION.....................
More informationFire precautions in dwellings
NORWICH City Council Fire precautions in dwellings Private sector housing Providing homes building communities Version 2 Published by Norwich City Council June 2010 Contents Page Introduction 1 2 Types
More informationConnevans. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at
Connevans Solutions to improve the quality of life This product may be purchased from Connevans Limited secure online store at www.deafequipment.co.uk DeafEquipment.co.uk Solutions to improve the quality
More informationCarbon Monoxide Alarms for Boats
Carbon Monoxide Alarms for Boats Carbon Monoxide Alarms for Boats The BSS/CoGDEM brochure Carbon Monoxide Safety on Boats gives full advice on how to stay safe from carbon monoxide (CO) poisoning aboard
More information230V~ SMOKE & HEAT ALARMS. with Alkaline Battery Backup. Instruction Manual. Contact Us
Ei140RC Series 230V~ SMOKE & HEAT ALARMS with Alkaline Battery Backup Instruction Manual Contact Us Aico Ltd Mile End Business Park, Maesbury Rd, Oswestry, Shropshire SY10 8NN, U.K. Tel: 01691 664100 www.aico.co.uk
More informationNG-9B NATURAL GAS ALARM
User Manual NG-9B NATURAL GAS ALARM Detects gas from household appliances NG-9B 1 Do not ignore any warning from your Natural Gas Alarm! Vacate the property and immediately call the UK Gas Emergency Service
More informationU S E R M A N U A L UBH1RF HEAT ALARM
U S E R M A N U A L UBH1RF HEAT ALARM OverView This heat alarm is a fire detection and alarm device which gives off an audible and visual warning when the ambient temperature reaches 54 C to 70 C. These
More informationAVAILABLE TO DOWNLOAD ON THE APOLLO APP. Pocket guide to. Fire Alarm Systems Design BS Standard
Pocket guide to Fire Alarm Systems Design BS 5839-1 Standard AVAILABLE TO DOWNLOAD ON THE APOLLO APP The Regulatory Reform (Fire Safety) Order (FSO) became law on 1 October 2006 Legally you must comply!
More informationSMOKE/CARBON MONOXIDE DETECTOR REQUIREMENTS
HOMES BUILT PRIOR TO JANUARY 1, 1975 WITH NO RENOVATIONS As of December 1, 2016, upon sale or transfer Must be located on every level of the residence Must be located on the ceiling at the base of each
More informationA Guide To BS Understanding the selection, spacing and siting of detectors
World Class Leaders in Fire Detection Since 1918 A Guide To BS5839-12017 Understanding the selection, spacing and siting of detectors Welcome to A Guide to BS5839 Part 1 : 2017 from HOCHIKI EUROPE (UK)
More informationSI-610 / SO-610 User Manual. 10 Year Smoke Alarm Standard / Toast Proof with Smart Silence
SI-610 / SO-610 User Manual 10 Year Smoke Alarm Standard / Toast Proof with Smart Silence INTRODUCTION 2 AUTOMATIC POWER ENGAGE 2 SENSOR TECHNOLOGY 3 APPLICATION 4 POSITIONING 7 LIMITATIONS 9 HOW TO INSTALL
More informationLSI-601 / LSO-601 User Manual. Smoke Alarm Standard / Toast Proof with Ultra Bright Escape Light
LSI-601 / LSO-601 User Manual Smoke Alarm Standard / Toast Proof with Ultra Bright Escape Light INTRODUCTION 2 BLUESCAPE ULTRA BRIGHT TECHNOLOGY 2 SENSOR TECHNOLOGY 3 APPLICATION 3 POSITIONING 6 LIMITATIONS
More informationBS 5839 Part 6 : 2013 Changes. By Don Scott
BS 5839 Part 6 : 2013 Changes By Don Scott BS 5839 Part 6 : 2013 This new edition of the CoP is not a full revision but contains technical changes It is recognized that a full revision is required and
More informationSmartLINK Module Ei3000MRF for Mains Powered Multi-Sensor Fire / Smoke / Heat / CO Alarms - Ei3000 Series
SmartLINK Module Ei3000MRF for Mains Powered Multi-Sensor Fire / Smoke / Heat / CO Alarms - Ei3000 Series Instruction Manual Read and retain carefully for as long as the product is being used. It contains
More informationLOW VOLTAGE PANEL SMOKE & HEAT ALARMS
LOW VOLTAGE PANEL SMOKE & HEAT ALARMS Ei181 Ei184 Ei186 P/N B14090 Rev4 Ei Electronics 2014 READ THIS FIRST CHECK OPERATION OF SYSTEM TEST BUTTONS OPERATE ON ALL ALARMS. ALL INTERCONNECTED ALARMS OPERATE
More information169MHz Telecare Devices Carbon Monoxide Detector
169MHz Telecare Devices Carbon Monoxide Detector Compatible with Reach at home alarms, Advent xt warden call, Altec Response and Touchsafe Pro Nursecall systems CO alarm activates on Time Weighted Average;
More informationFireTek : Easier installation. Superior performance.
1/10/2018 Smoke Alarms - Clipsal by Schneider Electric FireTek : Easier installation. Superior performance. Clipsal FireTek Smoke Alarms deliver dependable safety, with subtle style to complement any interior
More informationCarbon Monoxide Alarms Smoke and Carbon Alarms Upgrade Requirements for Single and Two Family Dwellings
Planning and Building Department INFORMATIONAL GUIDE Updated: 2017 July 31 Smoke Alarms This brochure explains the requirements for smoke alarms in new or renovated buildings. It provides information to
More information2014 Alberta Building Code. Part 9 changes relating to Smoke and CO Alarms
2014 Alberta Building Code Part 9 changes relating to Smoke and CO Alarms 9.32.3.9 Carbon Monoxide Alarms What has not changed: 4) & 6) In a residential occupancy containing a fuel burning appliance or
More informationMelrose Fire Department
Melrose Fire Department Office of Fire Prevention Re: 9/20/18 Guidelines for the Type and Placement of Smoke and Carbon Monoxide Alarms Purpose of this guide is to help homeowners protect their homes and
More informationSmoke Alarms and Carbon Monoxide Alarms
70 N 1st Street Campbell, California 95008 Phone (408) 866-2130 Fax (408) 871-5101 Smoke Alarms and Carbon Monoxide Alarms March, 2018 When building permits are issued for additions, alterations or repairs
More informationSmoke Alarm Legislation
THE REQUIREMENT FOR SMOKE ALARMS Is it law for residential properties to have mains powered smoke alarms installed? The Building Regulations 2012 require owners to install compliant mains powered smoke
More information169MHz Telecare Devices Gas & Carbon Monoxide Detector
169MHz Telecare Devices Gas & Carbon Monoxide Detector Compatible with Reach at-home alarms, Advent xt warden call, Altec Response and Touchsafe Pro Nursecall systems Gas alarm activates at 10% of Lower
More informationUSER INSTRUCTIONS MULTI-SENSOR FIRE ALARM 230V~ with Rechargeable Lithium Cell Back-up. Model: Ei2110
230V~ MULTI-SENSOR FIRE ALARM with Rechargeable Lithium Cell Back-up Model: Ei2110 Contains vital information on unit operation and installation. Read and retain carefully. If you are just installing this
More informationSmoke and Heat alarm User Guide
1385-7205-05_NB:_ 2018.9.6 5:05 PM Page 1 Please read through our guide in full. It should be retained for future reference. Cut out page 6 and pin up near your Consumer Unit/Fuse Box. Leading authorities
More informationOverview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.
Wireless Overview www.incitefire.com.au Overview Fundamentals FIREwave is a wireless based family of products which is fully integrated into Hochiki s renowned ESP intelligent hardwired system. This seamless
More information420 MASTER & SLAVE MULTI MESSAGE
New Zealand Smoke Alarms 420 MASTER & SLAVE MULTI MESSAGE Product Guide 2011 Smoke & Heat Alarms Product Guide Index 600 Series Photoelectric and Heat Alarms Page 1 600 Series 10 Year Lithium Cell Battery
More informationcarbon monoxide alarms
Cl/SfB (68.52) Uniclass L7625 December 2018 Your first line of defence for housing safety in an uncertain world carbon monoxide alarms a specifiers guide to regulations & standards Introduction Kidde is
More informationConnevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at
Connevans.info Solutions to improve the quality of life Offering you choice Helping you choose This product may be purchased from Connevans Limited secure online store at www.deafequipment.co.uk DeafEquipment.co.uk
More informationFirehawk Fire Alarms Battery Powered. Information, Installation and Maintenance
Firehawk Fire Alarms Battery Powered Information, Installation and Maintenance FHB10 Smoke Alarm FHH10i Heat Alarm Sounder FHB10 / 10i Smoke Alarm FHH10i Heat Alarm Red LED FHB10 / 10i Smoke Alarm FHH10i
More informationThe new detector from Rafiki
The new detector from Rafiki Three smoke detectors Three heat detectors Combined smoke/heat detector Full alarm sounder Strobe End-of-line device/loop isolator Rafiki s Multipoint ASD detector range have
More information230V Interconnectable Mains Operated Alarm model. For: 1275H
Smoke alarm Owner s Manual 230V Interconnectable Mains Operated Alarm model For: 1275H Your home is protected with a KIDDE Safety alarm. Please read through our guide in full. It should be retained for
More informationCentaurPlus ZW and HRT4-ZW
CentaurPlus ZW and HRT4-ZW Installation Instructions The Horstmann CentaurPlus ZW combined wireless room stat and timeswitch allows a combi boiler system to have a room thermostat added without the need
More informationB16351-R0-Ei2100 SERIES-USE.qxd 18/9/08 3:47 PM Page 1 230V~ MULTI-SENSOR FIRE ALARM with Rechargeable Lithium Cell Back-up.
B16351-R0-Ei2100 SERIES-USE.qxd 18/9/08 3:47 PM Page 1 230V~ MULTI-SENSOR FIRE ALARM with Rechargeable Lithium Cell Back-up Model: Ei2110 Contains vital information on unit operation and installation.
More informationSAFEGUARD YOUR HOME WITH QUELL
THE INCONVENIENT TRUTH ABOUT HOUSEHOLD FIRES Australian law mandates that all residences have at least one smoke alarm installed on each level of the home and for good reason. Fire represents a serious
More informationFire Safety and Whole Home Protection
PRODUCT CATALOGUE Distribution Partner Fire Safety and Whole Home Protection SMOKE AND FIRE FACTS CHOOSING THE RIGHT ALARM First Alert, one of the most recognized safety brands in Canada, offers an array
More information7 YEAR LIFE CARBON MONOXIDE POISONOUS GAS ALARM
CO-9X User Manual 7 YEAR LIFE CARBON MONOXIDE POISONOUS GAS ALARM Please read me as I could save your life. Please retain this user manual for future reference CONTENTS INTRODUCTION FEATURES CARBON MONOXIDE
More informationSmoke Alarms. Clipsal FireTek. Photoelectric Smoke Alarms. clipsal.com/smokealarms
Clipsal FireTek Smoke Alarms Photoelectric Smoke Alarms clipsal.com/smokealarms Iconic and Clipsal Iconic are trademarks of Schneider Electric (Australia) PTY Limited. 2 clipsal.com/smokealarms Your customers
More informationAnalogue addressable devices
Apollo XP95 Analogue addressable devices from Channel Safety Systems Apollo XP95 Analogue addressable devices The XP95 range of analogue addressable fire detectors is advanced in design, improved in performance
More informationSensors (All Fully Customisable)
SafeGuard Safe Guard modular Wireless GSM Sensors and Detectors Compact GSM Wireless Alarm System Sensors (All Fully Customisable) Security Fire Smoke / Gas Flooding Chemical Temperature Eco Battery Up
More informationHowler Go-Link Evacuation Alarm
Howler Go-Link Evacuation Alarm Go simple, GoLink In an age of sophistication, complexity and novelty, we sometimes lose sight of what we actually need, and ultimately what we actually want. When it comes
More informationSmoke & Carbon Monoxide
A Guide to the Massachusetts Smoke & Carbon Monoxide Requirements when Selling a Oneor Two-Family Residence FIRE SERVICES Department of Fire Services PO Box 1025 Stow, MA 01775 978-567-3300 www.mass.gov/dfs
More informationSmoke Alarm User Manual
Smoke Alarm User Manual Model number: GS528A Ref:ST528A Thank you for purchasing our smoke alarm. Please take a few minutes to read the user s manual thoroughly and familiarize yourself and your family
More informationConstruction Products Regulation (CPR) Update. Graham Simons Technical Manager, FIA
Construction Products Regulation (CPR) Update Graham Simons Technical Manager, FIA What are we talking about? Construction Products Regulation 305/2011 EU (CPR) Replaced Construction Products Directive
More informationProfessional Home Safety. X-Series CO Alarms. Battery Powered Carbon Monoxide Alarms XC70, XC100, XC100D
Professional Home Safety CO X-Series CO Alarms Battery Powered Carbon Monoxide Alarms XC70, XC100, XC100D Carbon Monoxide (CO) in Residential Accommodation The dangers of Carbon Monoxide Carbon Monoxide
More informationA GUIDE TO FIRE DETECTION AND ALARM SYSTEMS
A GUIDE TO FIRE DETECTION AND ALARM SYSTEMS A Fire detection and alarm ( FD+a ) system is what most workplaces and public accessed buildings have in place. The FD+a system has two primary functions and
More informationMINERVA MZX125 Digital Addressable Fire Detection System
DATASHEET MINERVA MZX125 Digital Addressable Fire Detection System The Minerva MZX125 is a highly featured digital addressable panel with a comprehensive but easy to operate user interface. The system
More informationModel: Ei450. Instruction Manual
Alarm Controller Fire and CO Model: Ei450 Instruction Manual Read and retain carefully for as long as the product is being used. It contains vital information on the operation and installation of your
More information169MHz Telecare Devices. Gas Detector
169MHz Telecare Devices Gas Detector Compatible with Reach at-home alarms, Advent xt warden call, Altec Response and Touchsafe Pro Nursecall systems Alarm at 10% of LEL (Lower Explosive Limit) 85dB @ 1m
More informationCarbon Monoxide Detector
169MHz Telecare Devices Carbon Monoxide Detector Compatible with Reach at-home alarms, Advent xt warden call, Altec Response and Touchsafe Pro Nursecall systems Advanced electrochemical sensor technology
More informationNorthern Ireland HMO Fire Safety Guide
Northern Ireland HMO Fire Safety Guide 2 February 2018 Contents Equality Statement 5 Houses in Multiple Occupation (HMO) Fire Safety Standards 6 1.0 Introduction 6 2.0 Definition of Houses in Multiple
More informationBarnsley Accredited Landlord Scheme Accredited Property Registration Form
Barnsley Accredited Landlord Scheme Accredited Property Registration Form Property address (to be accredited) Property and Membership Detail Post Code Members full name, including title Trading as/ Company
More informationAlarm Controller Fire and CO
Alarm Controller Fire and CO Model: Ei450 Instruction Manual Read and retain carefully for as long as the product is being used. It contains vital information on the operation and installation of your
More informationUSER S MANUAL. BATTERY POWERED PHOTOELECTRIC SMOKE ALARM WITH SILENCE FEATURE Models 710E, 710LE and SA710CE
USER S MANUAL BATTERY POWERED PHOTOELECTRIC SMOKE ALARM WITH SILENCE FEATURE Models 710E, 710LE and SA710CE IMPORTANT! PLEASE READ CAREFULLY AND SAVE. This user s manual contains important information
More informationTest Report Garvan Enterprises Limited
Test Report 8526255. Garvan Enterprises Limited Page 1 of 14 Introduction. This report has been prepared by A Reeve and relates to the activity detailed below: Job/Registration Details Job number: 8526255
More informationConnevans. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at
Connevans Solutions to improve the quality of life This product may be purchased from Connevans Limited secure online store at www.deafequipment.co.uk DeafEquipment.co.uk Solutions to improve the quality
More informationDesign of Fire safety in Multi Occupancy Residential Accommodation
Design of Fire safety in Multi Occupancy Residential Accommodation Myth vs Reality Myth. Fire is bright Reality. It isn t. Flames are bright Outside fires have bright flames because of the availability
More informationThe Smoke and Carbon Monoxide Alarm (England) Regulations 2015
The Smoke and Carbon Monoxide Alarm (England) Regulations 2015 Q&A Booklet for the Private Rented Sector landlords and tenants September 2015 Department for Communities and Local Government Crown copyright,
More informationSmoke and Heat alarm Ownerʼs Manual
1385-7205-00_V8:_ 2011.3.14 5:20 PM Page 1 COMPATIBLE Your home is protected with a KIDDE Fyrnetics alarm/s Please read through our guide in full. It should be retained for future reference. Cut out page
More informationProfessional Home Safety. X-Series CO Alarms. Battery Powered Carbon Monoxide Alarms XC70, XC100, XC100D
Professional Home Safety CO X-Series CO Alarms Battery Powered Carbon Monoxide Alarms XC70, XC100, XC100D Carbon Monoxide (CO) in Residential Accommodation The dangers of Carbon Monoxide Carbon Monoxide
More informationExcellence in Level Measurement
Technical Data Sheet No. Novaflo 2000 'Fail-Safe' Level Alarm System Excellence in Level Measurement Afriso Eurogauge Ltd Imberhorne Lane, East Grinstead West Sussex. RH19 1RF Tel: 01342 323641 Fax: 01342
More informationCO-808S User Manual. Carbon Monoxide Poisonous Gas Alarm With Sealed 6 Year Power Pack
CO-808S User Manual Carbon Monoxide Poisonous Gas Alarm With Sealed 6 Year Power Pack INTRODUCTION 2 FEATURES 2 CARBON MONOXIDE AND HOW IT CAN AFFECT YOUR FAMILY 3 WHERE TO INSTALL YOUR DETECTOR 6 HOW
More information5000 INSTALLATION GUIDE
5000 INSTALLATION GUIDE Table of Contents Section Page No 1. INTRODUCTION... 3 2. WARNINGS AND CAUTIONS... 3 3. UNPACKING... 3 4. INSTALLATION... 4 5. CONTROL PANEL - REMOVING ITEMS BEFORE MOUNTING...
More informationElectrical rating 230V AC, 50Hz 100mA max per (maximum 35mA for originating unit with 16 Devices interconnected).
1209-7201-02(21008418)_V2:_ 2011.4.19 9:13 AM Page 1 Wireless Alarm Base RF-SFTP 230V Mains Operated Wireless Interconnectable Alarm Base with Rechargeable Battery Backup For use with the following models
More informationEFBW series - BiWire Ultra control panel
4.2 Control panels and repeater panels EFBW series - BiWire Ultra control panel Eaton s new BiWire Ultra fire detection system is unlike any other standard conventional system as the panel, conventional
More informationUSER MANUAL CEF AP28 CONTROL PANEL
USER MANUAL CEF AP28 CONTROL PANEL AP28 WARNINGS This product has mains voltage present within the housing. Please take the necessary precautions in not allowing any liquid to spill on or into the housing.
More informationPLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE.
OPTICAL SMOKE ALARM DEVICE Commercial reference: 2103-002 Developed by CAVIUS The smoke alarm is designed for private homes, camping trailers, mobile homes and caravans. It is not recommended for boats.
More informationOwner's Manual BARFS-1 Rev 2.1. Residential Fire System
BARFS-1 Rev 2.1 BARFS-1 Residential Fire System MA360 Mar 2015 Table of Contents 1 INTRODUCTION 5 2 SYSTEM OVERVIEW 6 3 SYSTEM DESIGN 7 3.1 SMOKE / HEAT ALARM ----------------------------------------------------------------------------------
More informationBattery Powered Smoke & Heat Alarms Ei600 Series
Battery Powered Smoke & Heat Alarms Ei600 Series Ei605 Smoke Alarm Series Instructions Ei603 Heat Alarm Series Read and retain carefully for as long as the product is being used. It contains vital information
More informationBattery Powered Smoke Alarms Ei650 Series
Battery Powered Smoke Alarms Ei650 Series Read and retain carefully for as long as the product is being used. It contains vital information on the operation and installation of your Smoke Alarm. The leaflet
More informationRF280THS. Installation Instructions Wireless (RF) Photoelectric Smoke Detectors
RF80THS EN Installation Instructions Wireless (RF) Photoelectric Smoke Detectors RF80THS Installation Instructions Trademarks Trademarks Chamber Check is a registered trademark of Bosch Security Systems
More informationMFES READY Make your home fire safe. Home Smoke Alarms
MFES READY Make your home fire safe Home Smoke Alarms Working smoke alarms keep you and your family safe. It s the law and it could save your life and the lives of your loved ones. Are you READY to Make
More informationSeries 65 Product Guide MAN 3036
Series 65 Product Guide MAN 3036 TABLE OF CONTENTS Page No. 1 Ionisation Smoke Detector... 1 1.1 Operating Principles:... 1 1.2 Product Codes... 2 1.3 Integrating Version:... 2 1.4 Options:... 2 1.5 Safety
More informationSystem 800 Addressable Fire Detection & Alarm System
SECTION 5: page 1 Section 5: System 800 Addressable Fire Detection & Alarm System SECTION 5: page 3 10 reasons to specify 800 1 Plug and Play A user friendly panel not requiring special software tools
More informationFAQ. (Frequently Asked Questions) What is required to convert my unfinished basement to finished space?
NEW CASTLE COUNTY DEPARTMENT OF LAND USE FAQ (Frequently Asked Questions) What is required to convert my unfinished basement to finished space? 1. To convert an unfinished basement to finished space, at
More informationG-TECTA Cellaguard Carbon Dioxide and Oxygen Fixed Monitors
G-TECTA Cellaguard Carbon Dioxide and Oxygen Fixed Monitors EN Operating Manual 2 3 Contents Safety and Warning information 2 Introduction 3 Operation & Set Up 3 Cellaguard Features 3 Initial Set Up 4
More informationDANGER DETECTORS 2016 RANGE
ABUS UK www.abus.com DANGER DETECTORS 2016 RANGE Robust monitoring for underestimated risks: smoke and danger detectors Q4, 2015 CONTENTS EVERYTHING AT A GLANCE DANGER DETECTORS 2016 RANGE In this catalogue,
More informationRE214 Smoke Alarm Honeywell Compatible
Resolution Compatibles Smoke Alarm is a fire-protection device that alarms when it detects smoke or temperatures above 135 F (57 C). Features UL217 and ULC531 listings Smoke and heat detection 5 year warranty
More informationRadioLINK Alarm Base. Instructions. Model: Ei168RC
RadioLINK Alarm Base Model: Ei168RC Instructions Read and retain carefully for as long as the product is being used. It contains vital information on the operation and installation. This booklet should
More informationWIRELESS GAS DETECTION & SHUT OFF SYSTEM INSTRUCTION MANUAL. Wireless Gas Detection & Shut Off System - User Manual & Instructions
Wireless Gas Detection & Shut Off System - User Manual & Instructions Please read and follow these instructions prior to installation of the system as correct installation is critical to the performance
More information