Design of Fire safety in Multi Occupancy Residential Accommodation

Size: px
Start display at page:

Download "Design of Fire safety in Multi Occupancy Residential Accommodation"

Transcription

1 Design of Fire safety in Multi Occupancy Residential Accommodation

2 Myth vs Reality Myth. Fire is bright Reality. It isn t. Flames are bright Outside fires have bright flames because of the availability of oxygen and because the products of fire can escape

3 Myth vs Reality Myth. Fires inside are dark Reality. Fire starts bright, but quickly produces black smoke and Complete darkness. If you wake up to a fire you may be blinded, disoriented and unable to find your way around the home you ve lived in for years. Note the handprints along the wall

4 Myth vs Reality Myth. You can always outrun a fire Reality. You can t. Fire can spread extremely fast In less than 30 seconds a small flame can get completely out of control and turn into a major fire Most fires in the home occur when people are asleep

5 Myth vs Reality Myth. It s only hot near the seat of the fire Reality. Hot gases expand and rise very quickly If this it what happens to the plastic cover of an emergency light... The pressure inside the room where the fire starts builds up as the gases expand

6 Myth vs Reality Myth. Fire doors are an expensive waste of time. Reality. Early warning is probably more important but fire doors pay for themselves as well as saving lives The owner of this property doesn t think they are an expensive waste of time!

7 Myth vs Reality Myth. Fire is deadly Remember this ad campaign? Reality. It isn t a myth! Although many more people die from toxic fumes and inhalation of super heated gases than die from burns

8

9 Legislation Current fire safety design has developed from 2 separate pieces of Legislation The Building Regulations The Regulatory Reform (Fire Safety) Order 2005 (The Fire Safety Order )

10 Legislation Why two separate pieces of legislation to deal with one hazard? The Building Regulations deal with the design and construction of such developments. The Fire Safety Order deals with fire safety issues in the common parts of all premises but does not apply to private domestic areas

11 Legislation The Building Regulations Means of escape Structural fire protection Surface spread of flame over walls and ceilings Detection and alarm Access for the fire service All dealt with through Building Control

12 Legislation The Fire Safety Order 2005 Places a duty to carry out a risk assessment Make premises as safe as reasonably practicable Dynamic changes depending on the risk Onus is on the responsible person Only applies to common areas but will need to take in account risk generated in private areas

13 Why the need for fire safety regulation? Estimated 4 out every 5 house fires go unreported 55,800 reported fires in residential properties attended by Fire and Rescue Authorities in deaths 11,200 recorded injuries

14 Guidance Approved Document B Volume 2 Buildings Other Than Dwelling Houses BS 9991 Fire Safety in the design, management and use of residential buildings

15 Approved Document B Traditional Build Approved Document B was developed for easy and forgiving masonry construction..

16 Approved Document B Internal planning of flats

17 Approved Document B Internal planning of flats

18 BS9991 Internal planning of flats Entrance from below Smoke alarm

19 BS9991 Internal planning of flats Entrance from above Smoke alarm

20 BS9991 Internal planning of flats Entrance from above Smoke alarm Heat Detector

21 BS9991 Internal planning of flats Consider this layout

22 Maisonettes with floor(s) at H>4.5m (Clause 9.5.2) Requirement for alternative escape(s) from non access level omitted if either; A protected stairway enclosure and an LD1 AFD system to BS subject to no floor >7.5 m above or below entrance level of maisonette); or A protected stairway enclosure and domestic sprinkler coverage in accordance with BS 9251 or BS EN within the unit. Flats with Galleries (Clause 9.6(e)) Additional limitation that gallery >50% of the area of the floor below should be treated as an inner room cannot be overcome by sprinkler protection in floor containing the gallery

23 BS9991 Open Plan Flats Single level only (and no galleries) Maximum 16m x 12m with an enclosed kitchen Maximum 10m x 8m with an open (but remotely sited) kitchen Minimum 2.25m floor to ceiling height Sprinklered (at least to BS9251) Fire detection and alarm to a LD1 Grade D standard (self contained fire detectors in all rooms and corridor)

24 BS9991 Typical Layouts (2 bed) 10m x 8m Open plan Inner bedrooms Increased detection Sprinkler protection

25 BS9991 Typical Layouts (3 bed) 12m x 16m AD-B compliant Open plan Inner bedrooms Increased detection Sprinkler protection

26 BS9991 General Requirements (Clause 5) Escape Windows / Doors (Clause 5.1(c)) Min opening size 0.33m2 / 450mm as per AD B Cill of dormer or rooflight 1.5m (1100mm in AD B) refers to Table 1 of BS 6180:2011 Permits the use of keys on escape windows and doors (advice to occupants) not inferred in AD-B

27 BS9991 Private Balconies Private balconies H<4.5m Enclosed balconies to be treated as an inner room Where balconies are enclosed and are contiguous with enclosed balconies to other flats, the fire resistance of the balcony structure and compartmentation to be maintained

28 BS9991 Private Balconies Private balconies H>4.5m Escape through not more than one access room Access room to be clearly visible from balcony Travel distance limits for single direction escape

29 BS9991 Communal Roof Gardens, Balconies & Terraces Single direction escape of 45m No limit on travel with alternative escape Protection of escape routes to conform with the requirements for either small buildings or single stair buildings >11m Need to consider evacuation of disabled where lift access is provided

30 BS9991 Common Escape Routes Balcony Deck Approach No limitations on travel distance on deck approach but all parts of the building need to be within 45 m of a fire main, measured along a line on which hose can be laid

31 Common Escape (Clause 7) Balcony Deck Approach (Clause 7.3 & Fig 5) Minimum fire resistance of 30 min Walking surface to be imperforate Down-stands depths were width of balcony is more than 2m between flats required( 0.3m-0.6m or be calculated). Need to prove that balcony will not be smoke logged if less than 1.8m from the building facade and single direction of escape. Manual calculations acceptable but CFD analysis may be most appropriate tool Single direction of escape further safeguarded by external balustrade to be imperforate. Wall, balcony soffit and balustrade should be of a Class 0 rating.

32 Common Escape (Clause 7) Common Corridor Approach (Clause 7.4) Single stair buildings > 11m and multi stair building

33 Common Escape (Clause 7) Common Corridor Approach (Clause 7.4) Natural ventilation (Clause 26) or Mechanical smoke control system option in lieu of crosscorridor fire doors and natural vents in code compliant layouts. or Mechanical smoke control system option may be considered to facilitate extended corridor solutions (quantitative comparative design required) or If sprinklered throughout the block of flats (excl EC facilities), travel distances can be doubled on common escape (Clause 23.2) 7.5m 15.0m 30.0m 60.0m

34 Common Escape (Clause 7) Smoke Control in Common Corridors (Clause 7.4) Refers to Clause 26 for details of smoke control requirements. Vent to stairs must be an AOV (1.0m2) (Clause ) Clause (options a, b or c) all refer to requirements for common lobby / corridor immediately adjacent to the stair NOTE 3 The shaded area indicates the area requiring a smoke control system.

35 Common Escape (Clause 7) Common corridor in multi stair

36 Common Escape (Clause 7) Common corridor in multi stair condition Ex Fig 7 of BS 9991 BS 9991 Clause refers to for venting requirements specified corridor AOV of 1.5m2 / stair AOV 1.0m2. however... vents to the exterior of the building may also be manually operated.. (Clause ) and only refers to automatic venting over stairs

37 Common Escape (Clause 7) Common Corridor Approach: Small Single Stair < 11m (Clause 7.5 & Fig 8) Criteria largely as per AD B except for a few notable changes

38 Common Escape (Clause 7) Common Corridor Approach: Small Single Stair < 11m (Clause 7.5) Omits the requirement that ancillary areas and flats should not be on same floor level (Clause 12(b)(e)) Fig 8(b) design (two apartments per floor) stair ventilation must be by means of an AOV and not OVs (Clause ) Not applicable to Open Plan living layouts (unless the lobby to the stair is maintained)

39 Extra Care / Special Housing (Clause 8) Scope of BS 9991 code expanded to cover extra care and other special housing Max 9m travel within EC unit or provide alternative escape. Max 7.5m travel from flat door to storey exit or cross corridor door retained Need to consider adequate refuge space requirements in corridors / stairs Evac lifts to BS9999: 2008 where deemed necessary Free swing / hold open devices to be used in common circulation routes where self closers present an obstacle to movement Extra care facilities to be sprinkler protected (Clause 23.1)

40 Mist Systems

41

42

43 Access for Fire Service (Clause 18-21) Vehicular Access no internal fire main (Clause ) Access to all parts of dwellings within 45m (AD-B: Block of flats with no fire main requires access to within 45m of every point on the projected plan area to individual units) Can be increased on foot of sprinkler protection and where arrival time of fire service is not more than 10mins to 90m for houses (H<4.5m) to 75m for houses / flats (not more than one floor above 4.5m) Arrival time subject to consultation with Fire Service

44 Access for Fire Service (Clause 18-21) Residential Fire Fighting Shaft (Clause 19.2) Stair door to be FD60S Apartment corridor to serve as fire fighting lobby Can use additional fire mains in escape stair to meet coverage requirements; 60m from outlet in fire shaft 45m from outlet in escape stair

45 Active Fire Protection (Clause 22-26) Fire Alarm System (Clause 22) No requirement for common AFD system (Clause 22.1) other than to initiate smoke control systems Clause Unless a simultaneous evacuation arrangement is deemed appropriate, there should be no sounders attached to the smoke detectors within common parts. NOTE 2 The purpose of smoke detectors is to operate the smoke control system, not to raise an alarm Only non residential areas in mixed use buildings need have AFD fitted Risk assessment approach considered appropriate in determine AFD requirements for communal areas / roof gardens associated with sheltered housing

46 Active Fire Protection (Clause 22-26) Sprinkler & Watermist Systems (Clause 23) Sprinklers recommended for Buildings > 30m (and possibly H>18m) BS EN Extra Care developments Sprinkler protection trade-offs (discussed already) 3 storey house with open plan ground floor (Clause 6.3) 4 storey house with no 2 nd means of escape (Clause 6.4) Open plan flats (Clause 9.7) Increased distance vis vehicular access (Clause ) Increased travel in common corridors (Clause 7.4) Reduced boundary distance by half (Clause )

47 Active Fire Protection (Clause 22-26) Sprinkler & Watermist Systems (Clause 23) Watermist gets conditional approval in BS9991 subject to agreement of the relevant enforcing authority (Clause 23.1) Needs specific scenario testing to prove viability and effectiveness of each system

48 Active Fire Protection (Clause 22-26) Manual Fire Fighting equipment (Clause 24) Not required in common areas (unless risk assessment dictates otherwise) Employed in higher fire risk areas in sheltered housing Special Risk Protection (Clause 25) Where a common stair forms part of the only escape route from a flat, unless it is designated as a small single-stair building in accordance with 7.5, it should not also serve any covered car park, boiler room, fuel storage space or other ancillary accommodation of similar fire risk. At odds with 13.2 which permits sprinklered basement car park for single stairs buildings > 11m?

49 Any Questions

technical specification smoke venting systems

technical specification smoke venting systems technical specification smoke venting systems An Introduction to FDS FDS sets the standards the rest of the industry follows Providing a complete service for all of your smoke ventilation system needs.

More information

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NEW BUILDINGS

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NEW BUILDINGS FIRE RISK ASSESSMENT NEW BUILDINGS BUILDING SUMMARY The building is utilised for classroom teaching for Modern Languages. 1. Identification of the hazards 1.1 Identification of sources of fuel. Timber

More information

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT SPORTS CENTRE

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT SPORTS CENTRE FIRE RISK ASSESSMENT SPORTS CENTRE BUILDING SUMMARY The building is used as a Sports Centre and contains a large sports hall with changing rooms, an office for staff and a fitness area. 1. Identification

More information

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Pocket guide to. Fire Alarm Systems Design BS Standard

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Pocket guide to. Fire Alarm Systems Design BS Standard Pocket guide to Fire Alarm Systems Design BS 5839-1 Standard AVAILABLE TO DOWNLOAD ON THE APOLLO APP The Regulatory Reform (Fire Safety) Order (FSO) became law on 1 October 2006 Legally you must comply!

More information

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT HORSEFAIR HOUSE

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT HORSEFAIR HOUSE FIRE RISK ASSESSMENT HORSEFAIR HOUSE BUILDING SUMMARY The building is utilised for the teaching of Science and contains Laboratories and Chemical storage. 1. Identification of the hazards 1.1 Identification

More information

Fire resistance. Appendix E. E.1 Fire resistance. Appendix. (A copy of this Appendix is available on /)

Fire resistance. Appendix E. E.1 Fire resistance. Appendix. (A copy of this Appendix is available on /) Fire resistance (A copy of this is available on www.routledge.com/books/details/ 9780415809696/).1 Fire resistance The overall aim of fire safety precautions is to ensure that: all corridor doors shall

More information

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NO 68 (ENGLISH AND PHILOSOPHY)

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NO 68 (ENGLISH AND PHILOSOPHY) FIRE RISK ASSESSMENT NO 68 (ENGLISH AND PHILOSOPHY) BUILDING SUMMARY The building was constructed in Victorian times and is constructed of brick with knapped flint in fill on some outer walls. The building

More information

Fire Alarm Systems Design. incorporating Amendment No.2. a guide to BS5839. Part1:2002

Fire Alarm Systems Design. incorporating Amendment No.2. a guide to BS5839. Part1:2002 a guide to Fire Alarm Systems Design BS5839 Part1:2002 incorporating Amendment No.2 The Regulatory Reform (Fire Safety) Order (RRO) became law on 1 October 2006 Legally you must comply! What is the RRO?

More information

Fire precautions in dwellings

Fire precautions in dwellings NORWICH City Council Fire precautions in dwellings Private sector housing Providing homes building communities Version 2 Published by Norwich City Council June 2010 Contents Page Introduction 1 2 Types

More information

Element C3.5 Means of Escape

Element C3.5 Means of Escape .5 Means of Escape RRFSO Article 14 Legal Factors Responsible person must ensure routes to emergency exits and exits themselves are kept clear at all times Exits must directly lead to place of safety Safe

More information

Northern Ireland HMO Fire Safety Guide

Northern Ireland HMO Fire Safety Guide Northern Ireland HMO Fire Safety Guide 2 February 2018 Contents Equality Statement 5 Houses in Multiple Occupation (HMO) Fire Safety Standards 6 1.0 Introduction 6 2.0 Definition of Houses in Multiple

More information

Are you educated in safe emergency evacuation and fire safety risk assessments? Education: A Guide to Fire Safety

Are you educated in safe emergency evacuation and fire safety risk assessments? Education: A Guide to Fire Safety Are you educated in safe emergency evacuation and fire safety risk assessments? Education: A Guide to Fire Safety Managing fire risk within your school and providing an evacuation plan to all staff, pupils

More information

- CONSTRUCTION FIRE SAFETY STANDARDS

- CONSTRUCTION FIRE SAFETY STANDARDS SGG15 - CONSTRUCTION FIRE SAFETY STANDARDS 1) Construction Planning All construction sites shall plan and sequence their construction activities to ensure the early installation and operation of permanent

More information

Unit 2 Fire Safety (Zone 1)

Unit 2 Fire Safety (Zone 1) IFE Level 3 Diploma in Fire Safety and Fire Science Unit 2 Fire Safety (Zone 1) Examiner Report March 2018 Introduction 42% of candidates attained a Pass. Half of the candidates that attained a Pass secured

More information

FIRE SAFETY IN PURPOSE BUILT BLOCKS OF FLATS

FIRE SAFETY IN PURPOSE BUILT BLOCKS OF FLATS A GUIDE ON FIRE SAFETY IN PURPOSE BUILT BLOCKS OF FLATS INTRODUCTION Fire safety in blocks of flats is something that must be taken very seriously. The Local Government Group (LGG) was commissioned to

More information

The Code of Practice for Fire Safety in Buildings 2011 It comprises 7 parts and 1 annex:

The Code of Practice for Fire Safety in Buildings 2011 It comprises 7 parts and 1 annex: The Code of Practice for Fire Safety in Buildings 2011 It comprises 7 parts and 1 annex: Mr. Junkers Lam Senior Building Surveyor of Buildings Department (9 Sept 2013) Part A Introduction Part B Means

More information

Technical Seminar on the Code of Practice for Fire Safety in Buildings 2011

Technical Seminar on the Code of Practice for Fire Safety in Buildings 2011 Technical Seminar on the Code of Practice for Fire Safety in Buildings 2011 The Code of Practice for Fire Safety in Buildings 2011 The FS Code comprises 7 parts and 1 annex: Part A Introduction Part B

More information

NEW PROJECTS DOCUMENTATION FOR OCCUPATION - REGULATION 38 FIRE STRATEGIES, DRAWINGS & INFORMATION EMPLOYER S REQUIREMENTS

NEW PROJECTS DOCUMENTATION FOR OCCUPATION - REGULATION 38 FIRE STRATEGIES, DRAWINGS & INFORMATION EMPLOYER S REQUIREMENTS Mandatory Fire Safety Instruction NEW PROJECTS DOCUMENTATION FOR OCCUPATION - REGULATION 38 FIRE STRATEGIES, DRAWINGS & INFORMATION EMPLOYER S REQUIREMENTS Reference A: Reference B: Approved Document B

More information

161 Rosebery Avenue, London, EC1 Fire Safety Management Plan & Evacuation Procedures

161 Rosebery Avenue, London, EC1 Fire Safety Management Plan & Evacuation Procedures 161 Rosebery Avenue, London, EC1 Fire Safety Management Plan & Evacuation Procedures Contents 1.0 Introduction 2.0 Means of Escape in Case of Fire 3.0 Means for Giving Warning in Case of Fire 4.0 Means

More information

WORKSHEET 4-1 THE MANITOBA FIRE RISK INDEX FOR THE RESIDENTIAL OCCUPANCY OF HERITAGE BUILDINGS FIRE SAFETY PARAMETERS

WORKSHEET 4-1 THE MANITOBA FIRE RISK INDEX FOR THE RESIDENTIAL OCCUPANCY OF HERITAGE BUILDINGS FIRE SAFETY PARAMETERS 1 WORKSHEET 4-1 THE MANITOBA FIRE RISK INDEX FOR THE RESIDENTIAL OCCUPANCY OF HERITAGE BUILDINGS FIRE SAFETY PARAMETERS TABLE 4.1 CONSTRUCTION OF STRUCTURAL MEMBERS AND FLOOR AND ROOF ASSEMBLIES Construction

More information

BUILDING FIRE STRATEGY

BUILDING FIRE STRATEGY UCL ESTATES Fire Safety UNIVERSITY COLLEGE LONDON BUILDING FIRE STRATEGY Regulatory Reform (Fire Safety) Order 2005, BS 9999: 2008 (Annex H) & BS PAS 911 Name & Address of Building: DEVELOPMENT PLANNING

More information

2012 B.C. Building Code Compliance Review (Division B Part 3)

2012 B.C. Building Code Compliance Review (Division B Part 3) Planning and Building Department 2012 B.C. Building Code Compliance Review PROJECT NAME:.. CIVIC ADDRESS:...... PERMIT APPLICATION NO.:. DATE:... I,, have: 1. reviewed the design, plans and supporting

More information

WORKSHEET 2-1 THE MANITOBA RESIDENTIAL OCCUPANCY FIRE RISK INDEX FIRE SAFETY PARAMETER VALUES

WORKSHEET 2-1 THE MANITOBA RESIDENTIAL OCCUPANCY FIRE RISK INDEX FIRE SAFETY PARAMETER VALUES 1 WORKSHEET 2-1 THE MANITOBA RESIDENTIAL OCCUPANCY FIRE RISK INDEX FIRE SAFETY PARAMETER VALUES TABLE 2.1 CONSTRUCTION OF STRUCTURAL MEMBERS AND FLOOR AND ROOF (1) ASSEMBLIES (Applies to each fire zone)

More information

fire risk assessment For use by landlords of small premises Premises Address

fire risk assessment For use by landlords of small premises Premises Address fire risk assessment For use by landlords of small premises Premises Address FIRE RISK ASSESSMENT for use by landlords of small premises Person having control of the premises: Name of landlord (if different):

More information

Fire protection documentation. CFPA-E Guideline No 13:2015 F

Fire protection documentation. CFPA-E Guideline No 13:2015 F Fire protection documentation CFPA-E Guideline No 13:2015 F FOREWORD The European fire protection associations have decided to produce common guidelines in order to achieve similar interpretation in the

More information

UCL PRINCIPAL CONTRACTOR SITE FIRE SAFETY RISK REVIEW & MITIGATION MEASURES

UCL PRINCIPAL CONTRACTOR SITE FIRE SAFETY RISK REVIEW & MITIGATION MEASURES Mandatory Fire Safety Instruction UCL PRINCIPAL CONTRACTOR SITE FIRE SAFETY RISK REVIEW & MITIGATION MEASURES Principal Contractor fire safety considerations in shared occupancy project or refurbishments

More information

3.1 Introduction. 3.1 Introduction

3.1 Introduction. 3.1 Introduction DEPARTMENT OF ARCHITECTURE ABUBAKAR TAFAWA BALEWA UNIVERSITY, BAUCHI ARC 624: ADVANCED BUILDING SERVICES LESSON 3: FIRE DETECTION AND ALARM SYSTEMS IN BUILDINGS 3.1 Introduction 3.1 Introduction 3.2 Conventional

More information

FIRE RISK ASSESSMENT

FIRE RISK ASSESSMENT FIRE RISK ASSESSMENT Full Property Name: St Augustine s Catholic Voluntary Academy Full Property Address: Opposite 93 PE9 1SR Date of Fire Risk Assessment: 6 th June 2017 Name of Fire Risk Assessor: Peter

More information

FIRE RISK ASSESSMENT NOT KNOWN 15/10/ SOMERTON COURT BROADMOSS DRIVE SIMON ROFFEY

FIRE RISK ASSESSMENT NOT KNOWN 15/10/ SOMERTON COURT BROADMOSS DRIVE SIMON ROFFEY UPRN Date of inspection Address 1 (flat numbers) Address 2 (street) Address 3 (area) Fire Risk Assessor Checked by Approved by Postcode Does the building have common areas? Was access available to the

More information

Charlotte Building, 17 Gresse Street, London W1T 1QL

Charlotte Building, 17 Gresse Street, London W1T 1QL Charlotte Building, 17 Gresse Street, London W1T 1QL Fire Safety Management & Evacuation Procedures Contents 1.0 Introduction 2.0 Means of Escape in Case of Fire 3.0 Means for Giving Warning in Case of

More information

PROJECT: CIVIC ADDRESS:... PERMIT APPLICATION NO.: DATE:... CRP:. Certified Professional:.

PROJECT: CIVIC ADDRESS:... PERMIT APPLICATION NO.: DATE:... CRP:. Certified Professional:. 2012 B.C. Building Code Checklist (Division B Part 3) This checklist is provided as a reference only. The submission of this checklist with a Building Permit application should not be considered as a substitute

More information

Fire Safety Risk Assessment for Treowen, Wonastow, Monmouth, NP25 4DL

Fire Safety Risk Assessment for Treowen, Wonastow, Monmouth, NP25 4DL Fire Safety Risk Assessment for Treowen, Wonastow, Monmouth, NP25 4DL Record of significant findings Scope of Risk Assessment This fire safety risk assessment covers the use of Treowen as a venue for Civil

More information

Independent Living Scheme Fire Risk Assessment. Independent living sheltered residential accommodation and public library

Independent Living Scheme Fire Risk Assessment. Independent living sheltered residential accommodation and public library Independent Living Scheme Fire Risk Assessment Strelley Court Strelley Road Strelley ttingham NG8 3BJ At ttingham City Homes we want our residents to be assured that their homes are safe. We willingly

More information

AMBASSADOR HOUSE. A guide on. Fire Safety in Purpose Built Blocks of Flats

AMBASSADOR HOUSE. A guide on. Fire Safety in Purpose Built Blocks of Flats AMBASSADOR HOUSE A guide on Fire Safety in Purpose Built Blocks of Flats INTRODUCTION Fire safety in blocks of flats is something that must be taken very seriously. The Local Government Group (LGG) was

More information

Fire Risk Assessment

Fire Risk Assessment Fire Risk Assessment Maritime Studios Pendennis Rise Falmouth TR11 4FB Carried out by: Date: October 2015 Review Date: October 2016 Les Carter CMIOSH Health & Safety Consultant Mobile 07831 636751, Email

More information

MAINTENANCE OF ESSENTIAL SAFETY MEASURES EXPLAINED (Building Regulations 2006)

MAINTENANCE OF ESSENTIAL SAFETY MEASURES EXPLAINED (Building Regulations 2006) MAINTENANCE OF ESSENTIAL SAFETY MEASURES EXPLAINED (Building Regulations 2006) 1. INTRODUCTION 1.1 Essential Safety Measures Defined Essential Safety Measures (previously called essential services) are

More information

Fire Risk Assessment Guidance

Fire Risk Assessment Guidance Fire Risk Assessment Guidance This document is a guidance note to accompany the example fire risk assessment template. The example fire risk assessment template has been designed with small to medium domestic

More information

RESIDENTIAL CARE USER GUIDE UPDATES TO MANITOBA BUILDING/FIRE CODE:

RESIDENTIAL CARE USER GUIDE UPDATES TO MANITOBA BUILDING/FIRE CODE: RESIDENTIAL CARE USER GUIDE UPDATES TO MANITOBA BUILDING/FIRE CODE: Manitoba Regulation 221/2015 and Manitoba Regulation 222/2015 DATE: MARCH 17, 2016 1. INTRODUCTION On April 1, 2016, new building and

More information

Fire Risk Assessment

Fire Risk Assessment Fire Risk Assessment Carr House HS.F.119 (rev03) delivering promises, improving lives Contents 1 Premises particulars... 1 2 General statement of policy... 1 3 Management system... 1 4 General description

More information

Fire Risk Assessment

Fire Risk Assessment Fire Risk Assessment George Wright House HS.F.119 (rev03) delivering promises, improving lives Contents 1 Premises particulars... 1 2 General statement of policy... 1 3 Management system... 1 4 General

More information

Agency for Health Care Administration

Agency for Health Care Administration Page 1 of 100 FED - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS CFR Type Memo Tag FED - K9999 - FINAL OBSERVATIONS Title FINAL OBSERVATIONS CFR Type Memo Tag FED - KA100 - General Requirements - Other

More information

Secretary of State determination under article 36 of the Fire Safety Order

Secretary of State determination under article 36 of the Fire Safety Order Fire and Rescue Service Circular Circular number 48/2009 Date issued 13 August 2009 This circular is For information and consideration Status This circular covers the outcome of a referral to the Secretary

More information

Fire Safety. A TUC guide for trade union activists

Fire Safety. A TUC guide for trade union activists Fire Safety A TUC guide for trade union activists Contents Section one Introduction 3 Section two The law 4 Section three Fire risk assesment 5 Section four Policies and procedures 6 Section five Enforcement

More information

EMERGENCY EVACUATION PLAN

EMERGENCY EVACUATION PLAN UCL ESTATES & FACILITIES DIVISION Construction Maintenance & Fire Safety UNIVERSITY COLLEGE LONDON EMERGENCY PLAN Regulatory Reform (Fire Safety) Order 2005 Name & Address of Building: Occupying Department(s)

More information

Enclosure 4- RISK ASSESSMENT

Enclosure 4- RISK ASSESSMENT Enclosure 4- RISK ASSESSMENT RISK ASSESSMENT Risk is a potential that a chosen action or activity will lead to a loss of human or property. Risk assessment is a step for Risk Management. Risk assessment

More information

incorporating Guidance to Shafts for Smoke Control A useful guide to practical smoke shaft principals and specifications

incorporating Guidance to Shafts for Smoke Control A useful guide to practical smoke shaft principals and specifications incorporating Guidance to Shafts for Smoke Control A useful guide to practical smoke shaft principals and specifications Smoke shafts - an overview Scope of this guide Smoke shaft is the common term for

More information

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 PERIODIC REVIEW OF FIRE RISK ASSESSMENT

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 PERIODIC REVIEW OF FIRE RISK ASSESSMENT REGULATORY REFORM (FIRE SAFETY) ORDER 2005 PERIODIC REVIEW OF FIRE RISK ASSESSMENT Responsible person (e.g. employer) or person having control of the premises: Address of premises: Tel: Person(s) consulted:

More information

How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs

How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs 1 ABSTRACT Noureddine Benichou and Ahmed H. Kashef * Institute for Research in Construction National Research Council of Canada

More information

Chapter Nursing Homes

Chapter Nursing Homes Chapter 16.01 Nursing Homes Section 1. Licensing. No nursing, convalescent or old age home, as defined in Section 2 of this ordinance, shall be operated except under a license from the City Council of

More information

SPONSORED BY SOLUTIONS FIRE SAFETY AN INTRODUCTION

SPONSORED BY SOLUTIONS FIRE SAFETY AN INTRODUCTION SPONSORED BY SOLUTIONS FIRE SAFETY AN INTRODUCTION What are the main requirements? You must: Carry out a fire-risk assessment identifying any possible dangers and risks There previously existed over 70

More information

Fire Risk Management in Sheltered Housing

Fire Risk Management in Sheltered Housing Fire Risk Management in Sheltered Housing Paul Lane 22 March 2017 making the difference Fire Risk Management in Sheltered Housing Paul Lane 22 March 2017 making the difference Agenda What is Sheltered

More information

Fire Risk Assessment

Fire Risk Assessment Fire Risk Assessment Trinity House HS.F.119 (rev02) delivering promises, improving lives Contents 1 Premises particulars... 1 2 General statement of policy... 1 3 Management systems... 1 4 General description

More information

Technical Information

Technical Information How to design easily a smoke management system? Mechanical smoke extraction for enclosed car park Car park: specificity of the smoke extraction system Car parks are nowadays integrated directly inside

More information

Fire Risk Assessment

Fire Risk Assessment Fire Risk Assessment Manor House HS.F.119 (rev03) delivering promises improving lives Contents 1 Premises particulars... 1 2 General statement of policy... 1 3 Management systems... 1 4 General description

More information

A Guide To BS Understanding the selection, spacing and siting of detectors

A Guide To BS Understanding the selection, spacing and siting of detectors World Class Leaders in Fire Detection Since 1918 A Guide To BS5839-12017 Understanding the selection, spacing and siting of detectors Welcome to A Guide to BS5839 Part 1 : 2017 from HOCHIKI EUROPE (UK)

More information

FIRE SAFETY POLICY. Executive Management Team. Health, Safety and Fire Steering Group.

FIRE SAFETY POLICY. Executive Management Team. Health, Safety and Fire Steering Group. FIRE SAFETY POLICY Approver Executive Management Team Policy Fire Safety Policy Monitored By Health, Safety and Fire Steering Group. Date last revised April 2017 Revised by James Warne Next Revision Date

More information

Agency for Health Care Administration

Agency for Health Care Administration Page 1 of 92 FED - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS Type Memo Tag FED - K9999 - FINAL OBSERVATIONS Title FINAL OBSERVATIONS Type Memo Tag FED - KA100 - General Requirements - Other Title

More information

FIRE SAFETY IN SPECIALISED HOUSING GUIDANCE. Seamus Doyle Health & Safety Manager Pembrokeshire Housing Group

FIRE SAFETY IN SPECIALISED HOUSING GUIDANCE. Seamus Doyle Health & Safety Manager Pembrokeshire Housing Group FIRE SAFETY IN SPECIALISED HOUSING GUIDANCE Seamus Doyle Health & Safety Manager Pembrokeshire Housing Group Why a new guide? Changing social care landscape (3/4 million residents) Impact of Fire Safety

More information

EMLC Academy Trust. Fire Safety Policy 2017/19. Every child deserves to be the best they can be

EMLC Academy Trust. Fire Safety Policy 2017/19. Every child deserves to be the best they can be EMLC Academy Trust Fire Safety Policy 2017/19 Every child deserves to be the best they can be 1 Scope: EMLC Academy Trust & Academies within the Trust Version: 2 Filename: EMLC Academy Trust Fire Safety

More information

Some Important Aspects of Fire Safety Regulations about High Rise Buildings

Some Important Aspects of Fire Safety Regulations about High Rise Buildings Some Important Aspects of Fire Safety Regulations about High Rise Buildings Tokyo University of Science Prof. Kyoichi Kobayashi (Dr. of Engineering) Many high rise buildings are being built with awful

More information

DEF Fire Evacuation and Emergency Planning Criteria

DEF Fire Evacuation and Emergency Planning Criteria DEF Fire Evacuation and Emergency Planning Criteria This criteria should be used to devise individual DEF specific fire evacuation and emergency plans. It is the responsibility of the Clinic Team Leader

More information

FIA Guidance on Manual Call Point - Protection - False Alarm Mitigation

FIA Guidance on Manual Call Point - Protection - False Alarm Mitigation Guidance Note FIA Guidance on Manual Call Point - Protection - False Alarm Mitigation FIA Guidance on Manual Call Point - Protection False Alarm Mitigation 1. INTRODUCTION... 3 2. BS 5839-1 RECOMMENDATIONS...

More information

The Regulatory Reform (Fire Safety) Order Fire Risk Assessment Report

The Regulatory Reform (Fire Safety) Order Fire Risk Assessment Report 42 Haslucks Croft, Shirley, Solihull, B90 2EQ (t) 0121 249 1281 (m) 07814 203 977 www.veritas-consulting.co.uk The Regulatory Reform (Fire Safety) Order 2005 Fire Risk Assessment Report Client The Company

More information

Areas of the building to which access was not available. Details of any onsite management (if known)

Areas of the building to which access was not available. Details of any onsite management (if known) SECTION ONE UPRN Address 1 (block name and/or street number) Address 2 (flat numbers) Address 3 (street) Address 4 (area) Postcode Date of inspection Suggested review date Fire Risk Assessor Property Designation

More information

EMERGENCY EVACUATION PLAN

EMERGENCY EVACUATION PLAN UCL ESTATES & FACILITIES DIVISION Construction Maintenance & Fire Safety UNIVERSITY COLLEGE LONDON EMERGENCY EVACUATION PLAN Regulatory Reform (Fire Safety) Order 2005 Name & Address of Building: Occupying

More information

University of London

University of London University of London Senate House and Stewart House Fire safety arrangements Contents 1. Introduction p.2 2. Fire Risk Assessment documentation p.2 3. Action to be taken by a person discovering a fire

More information

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 PERIODIC REVIEW OF FIRE RISK ASSESSMENT

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 PERIODIC REVIEW OF FIRE RISK ASSESSMENT REGULATORY REFORM (FIRE SAFETY) ORDER 2005 PERIODIC REVIEW OF FIRE RISK ASSESSMENT Responsible person (e.g. employer) or person having control of the premises: Address of premises: Tel: Person(s) consulted:

More information

GDST Fire Safety Strategy March 2016

GDST Fire Safety Strategy March 2016 GDST Fire Safety Strategy March 2016 GDST Fire Safety Strategy v1.0 March 2016 Page 1 of 17 Contents 1. Introduction 3 2. Compliance Statement 3 3. Fire Safety Strategy Aims and Objectives 3 Strategic

More information

FIRE ALARM SYSTEMS FOR PURPOSE-BUILT FLATS & APARTMENTS: A NEW APPROACH

FIRE ALARM SYSTEMS FOR PURPOSE-BUILT FLATS & APARTMENTS: A NEW APPROACH FIRE ALARM SYSTEMS FOR PURPOSE-BUILT FLATS & APARTMENTS: A NEW APPROACH C-TEC HQ Typical tower block Andy Green Marketing Manager at C-TEC, a leading independent UK manufacturer of life safety electronic

More information

Application of the New Italian Fire Safety Code (D.M. 3 agosto 2015) to Case Study 3 Mall. Enrico Danzi Luca Fiorentini Luca Marmo Vincenzo Puccia

Application of the New Italian Fire Safety Code (D.M. 3 agosto 2015) to Case Study 3 Mall. Enrico Danzi Luca Fiorentini Luca Marmo Vincenzo Puccia Application of the New Italian Fire Safety Code (D.M. 3 agosto 2015) to Case Study 3 Mall Enrico Danzi Luca Fiorentini Luca Marmo Vincenzo Puccia A Challenging Application for the New Italian Fire Code

More information

FP-PGN-14 Part of NTW(O)41 Fire Policy

FP-PGN-14 Part of NTW(O)41 Fire Policy Fire Policy Practice Guidance Note Fire Evacuation in Trust Owned and Occupied Premises V02 Date Issued Issue 1 Aug 2017 Planned Review Aug - 2020 Responsible Officer Head of Estates & Facilities (NTW

More information

22 BISHOPSGATE Lift Evacuation Strategy

22 BISHOPSGATE Lift Evacuation Strategy June 28, 2018 22 BISHOPSGATE Lift Evacuation Strategy Romain Hourqueig, Head of UK Fire Engineering Neil Allardice, Senior Fire Engineer AGENDA The project Fire Safety Strategy Why lift evacuation? The

More information

Fire Risk Assessment Safety Checklist

Fire Risk Assessment Safety Checklist Fire Risk Assessment Safety Checklist This checklist has been prepared to help you comply with The Regulatory Reform Fire Safety Order 2005 What is the Regulatory Reform (Fire Safety) Order 2005? The Regulatory

More information

MEDIUM-DENSITY HOUSING # 7. Fire safety

MEDIUM-DENSITY HOUSING # 7. Fire safety BRANZ FACTS MEDIUM-DENSITY HOUSING # 7 Fire safety Moving from low-density to medium-density housing (MDH) involves people living in closer proximity. This has a number of implications for fire safety

More information

Why is this important?

Why is this important? Learning Objectives 1. The characteristics of fire, smoke and toxic fumes 2. Fire hazards involved in the working environment 3. Significant findings of relevant fire risk assessments 4. Practise and promote

More information

Design Guidelines Fire Safety in New and Refurbished Buildings

Design Guidelines Fire Safety in New and Refurbished Buildings Design Guidelines Fire Safety in New and Refurbished Buildings Introduction All major new or refurbishment projects must comply with the Technical Standards (Scotland) Regulations as a matter of course.

More information

- CONSTRUCTION FIRE SAFETY STANDARDS

- CONSTRUCTION FIRE SAFETY STANDARDS SGG15 - CONSTRUCTION FIRE SAFETY STANDARDS 1) Hot Work Permits All construction sites shall implement a system of Hot Work Permits for all work activities that generate heat, sparks or flames. All of the

More information

GENERAL FIRE SAFETY TERMS & DEFINITIONS

GENERAL FIRE SAFETY TERMS & DEFINITIONS UCL Fire Technical Note - TN006 Fire Safety Technical Guide GENERAL FIRE SAFETY TERMS & DEFINITIONS Reference: BS4422-2005 Fire Safety Vocabulary - for further information and definitions BS EN ISO 13943-2000:

More information

Learn About Fires Every day, Americans experience the horror of fire but most people don't understand it.

Learn About Fires Every day, Americans experience the horror of fire but most people don't understand it. Courtesy of Conrey Insurance Brokers Each year more than 3,275 people die and 15,575 are injured in home fires in the United States. To protect yourself, it is important to understand the basics about

More information

Approved Document. Fire safety. Volume 1 Dwellinghouses. The Building Regulations Came into effect April 2007

Approved Document. Fire safety. Volume 1 Dwellinghouses. The Building Regulations Came into effect April 2007 The Building Regulations 2010 Approved Document Volume 1 Dwellinghouses B Fire safety Came into effect April 2007 For use in Wales* 2006 edition incorporating 2010 and 2016 amendments VOLUME 1 This 2016

More information

Some information I have read tells me to evacuate immediately in case of fire. Fire In Your Residential Building. To Go?? To Stay??

Some information I have read tells me to evacuate immediately in case of fire. Fire In Your Residential Building. To Go?? To Stay?? Fire In Your Residential Building To Go?? or To Stay?? Your safety depends on the right decision. Your fire safety is your responsibility! If you live in an apartment or condominium, your safety also depends

More information

Fire Risk Assessment Guide

Fire Risk Assessment Guide Fire Risk Assessment Guide Thank you for your interest in the Fire Risk Assessment for your block. All of our blocks have had a recent Fire Risk Assessment in line with regulatory requirements and we are

More information

NEW PROJECTS DOCUMENTATION FOR OCCUPATION - REGULATION 38 FIRE STRATEGIES, DRAWINGS & INFORMATION REQUIREMENTS

NEW PROJECTS DOCUMENTATION FOR OCCUPATION - REGULATION 38 FIRE STRATEGIES, DRAWINGS & INFORMATION REQUIREMENTS Mandatory Fire Safety Instruction Reference A: Reference B: NEW PROJECTS DOCUMENTATION FOR OCCUPATION - REGULATION 38 FIRE STRATEGIES, DRAWINGS & INFORMATION REQUIREMENTS Approved Document B Fire Safety

More information

TGD Part B Fire Safety Volume 2 Dwelling Houses. Chris Barry B.Sc.,M.Sc., Pg. Dip. FSP, H.N.C. NDFEM

TGD Part B Fire Safety Volume 2 Dwelling Houses. Chris Barry B.Sc.,M.Sc., Pg. Dip. FSP, H.N.C. NDFEM TGD Part B Fire Safety Volume 2 Dwelling Houses Chris Barry B.Sc.,M.Sc., Pg. Dip. FSP, H.N.C. NDFEM Presentation Overview Review Rationale Review Process Legislation-Structure Section 0-Section 5 Appendix

More information

CHAPTER 7 ALTERATIONS LEVEL

CHAPTER 7 ALTERATIONS LEVEL CHAPTER 7 ALTERATIONS LEVEL 2 SECTION 701 GENERAL 701.1 Scope. Level 2 alterations as described in Section 404 shall comply with the requirements of this chapter. Exception: Buildings in which the reconfiguration

More information

Fire Risk Assessment Guide

Fire Risk Assessment Guide Fire Risk Assessment Guide Thank you for your interest in the Fire Risk Assessment for your block. All of our blocks have had a recent Fire Risk Assessment in line with regulatory requirements and we are

More information

TYPE 1 FIRE RISK ASSESSMENT REVIEW (NO DESTRUCTIVE AUDIT)

TYPE 1 FIRE RISK ASSESSMENT REVIEW (NO DESTRUCTIVE AUDIT) TYPE 1 FIRE RISK ASSESSMENT REVIEW (NO DESTRUCTIVE AUDIT) BRECON TOWERS BLACKBERRY LANE STOCKPORT SK5 8JW Date of this risk assessment review: 4th July 2017 Date of last risk assessment review: 8th May

More information

Guidance for writing a Personal Emergency Evacuation Plan (PEEP)

Guidance for writing a Personal Emergency Evacuation Plan (PEEP) Guidance for writing a Personal Emergency Evacuation Plan (PEEP) If assistance with escape is required, the extent of such assistance should be identified in the PEEP i.e. the number of assistants and

More information

5 Key Stages to Risk Assessment

5 Key Stages to Risk Assessment 5 Key Stages to Risk Assessment Stage 1: Identify Fire Hazards For a fire to start, three things are needed: A source of ignition Fuel Oxygen If any one of these is missing, a fire cannot start. Taking

More information

Fire Engineering in High Rise 15 November 2013

Fire Engineering in High Rise 15 November 2013 Fire Engineering in High Rise 15 November 2013 Neal Butterworth Arup UK www.arup.com Neal.Butterworth@arup.com Contents How do we protect against fire? How do we know this works? Why evacuate? What assumptions

More information

BUILDING FIRE STRATEGY

BUILDING FIRE STRATEGY UCL ESTATES Fire Safety UNIVERSITY COLLEGE LONDON BUILDING FIRE STRATEGY Regulatory Reform (Fire Safety) Order 2005, BS 9999: 2008 (Annex H) & BS PAS 911 Name & Address of Building: Occupying Department(s)

More information

Family Foster Home Fire Safety Evaluation Checklist Instructions

Family Foster Home Fire Safety Evaluation Checklist Instructions Family Foster Home Fire Safety Evaluation Checklist Instructions Please read these instructions prior to commencing your inspection. This checklist is provided to specific Foster Family Homes for the purpose

More information

Policy for Safe Evacuation of Persons with Disabilities

Policy for Safe Evacuation of Persons with Disabilities Policy for Safe Evacuation of Persons with Disabilities 1. Policy Statement The London School of Economics is committed to promoting access for people who have a disability or long-term medical condition.

More information

SEPTEMBER-NEWSLETTER-ELEVATOR DANGERS

SEPTEMBER-NEWSLETTER-ELEVATOR DANGERS SEPTEMBER-NEWSLETTER-ELEVATOR DANGERS Each year, firefighters are brought up to fire floors in high-rise buildings by elevator and are forced to run for their lives through a gauntlet of flame, heat and

More information

Building Construction i. approx. age ii. building structure iii. cladding iv. floors v. walls vi. roof

Building Construction i. approx. age ii. building structure iii. cladding iv. floors v. walls vi. roof SECTION ONE UPRN Address 1 (block name and/or street number) Address 2 (flat numbers) Address 3 (street) Address 4 (area) Postcode Date of inspection Suggested review date Fire Risk Assessor Property Designation

More information

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 PERIODIC REVIEW OF FIRE RISK ASSESSMENT

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 PERIODIC REVIEW OF FIRE RISK ASSESSMENT REGULATORY REFORM (FIRE SAFETY) ORDER 2005 PERIODIC REVIEW OF FIRE RISK ASSESSMENT Responsible person (e.g. employer) or person having control of the premises: Address of premises: Graham Care Group Cornford

More information

Fire Risk Assessment Guide

Fire Risk Assessment Guide Fire Risk Assessment Guide Thank you for your interest in the Fire Risk Assessment for your block. All of our blocks have had a recent Fire Risk Assessment in line with regulatory requirements and we are

More information

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE EMERGENCY PLAN

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE EMERGENCY PLAN REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE EMERGENCY PLAN This Emergency Plan has been developed following fire risk assessments of the relevant building. The purpose of the Plan is to ensure the

More information

Hong Kong Institute of Surveyors Pre-qualification Structural Learning. Code of Practice for Fire Safety in Buildings 2011 July 2012

Hong Kong Institute of Surveyors Pre-qualification Structural Learning. Code of Practice for Fire Safety in Buildings 2011 July 2012 Hong Kong Institute of Surveyors Pre-qualification Structural Learning Code of Practice for Fire Safety in Buildings 2011 July 2012 The Code of Practice for Fire Safety in Buildings 2011 The FS Code comprises

More information

UNIVERSITY COLLEGE LONDON EMERGENCY PLAN. Regulatory Reform (Fire Safety) Order 2005 PART ONE - SPECIFIC INSTRUCTIONS & OTHER RELEVANT INFORMATION:

UNIVERSITY COLLEGE LONDON EMERGENCY PLAN. Regulatory Reform (Fire Safety) Order 2005 PART ONE - SPECIFIC INSTRUCTIONS & OTHER RELEVANT INFORMATION: UCL ESTATES & FACILITIES DIVISION Construction Maintenance & Fire Safety UNIVERSITY COLLEGE LONDON EMERGENCY PLAN Regulatory Reform (Fire Safety) Order 2005 Name & Address of Building: Occupying Department(s)

More information