JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

Similar documents
Trailing Edge Dimmer. 32E450T Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

TrailingE dge Dimmer. 32E450T Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Universal Dimmer. 31E2RUD Series ROTARY CONTROL. Installation Instructions. Integrally Switched Rotary Controlled INTEGRALLY SWITCHED 240V

Universal Dimmer. 31E2RUD Series ROTARY CONTROL. Installation Instructions. Integrally Switched Rotary Controlled INTEGRALLY SWITCHED 240V

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

Universal Dimmer E450UD Series. Installation Instructions

RE-PR3-E-27 3-Phase Panel Mount 27kW

DIMAX DIMAX D GB F I E NL. Installation and operating instructions Universal dimmer DIMAX 532. Minimum DIMAX 532.

Dimmer / Fan Controller Installation Instructions

SERIES. LINE OF LIGHT (No Pixelation) FLEXIBLE DIRECT VIEW LINE VOLTAGE 150 MAXIMUM RUN LOW VOLTAGE 32 MAXIMUM RUN OUTDOOR RATED

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current. Output Voltage Range

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current

DALI Product Range. Designed in Australia to be compatible for all DALI systems. gerardlighting.com.au

56W Vapor Proof LED Fixture V Dimmable - DALI Network lms - IP67 - Outdoor Applications

APC BC300 Series 40kW 208/450/480V User Guide

Power Supply Display Module PSDM. Installation and Operation Manual

SHUTTLE BELL-PRESS DIMMER DATA SHEET

Dimmable General Area Use High Bay 320 Watt LED Light Fixture - Low Profile - High Efficiency

Controlling LEDs to meet. Russ MacAdam Director of Engineering Development

Skydance offers a complete AC Triac control system that contains Triac dimmer/ switch, Traic dimmable LED driver, and DMX512 Triac Converter.

OPTOTRONIC Power Supply OT96W/24V/UNV/DIM

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

Operation Manual Model: Light Switch Combo Universal Dimmer Module Item No.: WMR-252. Specification. Wiring

Product Bulletin for Decora Rocker Slide Controls

Universal pushbutton dimmer etd U2 etd 2e

TROPO 15W Dimmable LED Driver

EN , EN , DALI 102/207, SELV Output, KS C 7655 Safety Certification Approved RoHS Compliant. Dim. Method

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

Power Factor (2) 350 ma 90 ~ 132 Vac Vdc 35 W 86% 0.95 LLC-040S035RSP. Efficiency (2)

USER MANUAL TUNGSTEN SMART-HEAT ELECTRIC WIRELESS DIMMER CONTROLLER BY BROMIC IMPORTANT

START-LINE Receiver ACD-200. SMART Home USER MANUAL. Version 1.0 Visit for the most recent user manuals MAINS SOCKET DIMMER

AO Annunciator Module

QPM21 Series Duct CO 2 and Air Quality Sensors

PDU Power Distribution Unit for IP-NINJAR. User s Guide Ver

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

ILLUMINATOR EM. CENTRAL LIGHTING INVERTER 1000 VA/W through 2800 VA/W 98% Efficiency!

for relative humidity and temperature

Use of the application program

INTRODUCTION / TABLE OF CONTENTS

REA 105 Arc Protection Module. Operator s Manual

LC2200 Level Controller Installation and Maintenance Instructions

SYSTEM FIELD CUTTABLE SERIES

Emerald 3000 MK3 GJD010 Lighting Controller

ELLA ID. High CRI, High lm/w OptoDrive LED-module

Technical Instructions Document No. CE1N1961 March 17, Room CO 2 and Air Quality Sensors. Description. Features. Application

diode led 12VDC OMNIDRIVE 2 ELECTRONIC SPECIFICATION SHEET 12VDC OVERVIEW FEATURES DIMMABLE DRIVER

Installation Instructions

DIMAX DIMAX 534 plus D GB F I E nl. Installation and operating instructions Universal dimmer. DIMAX 534 plus

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

ELECTROPROJECT GTV-A POWER SUPPLY FOR DOOR MAGNETS

LED Linear Design Highlights

The Remote alarm Panel, TYPE RAPv2

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Square D Clipsal Outdoor Light-Level Sensor

MTRA-FSP Level Control Relay. Installation & Operation Manual

Max Load. Max. Load. Red (+) Black (-) Gray Violet. Part number: CV 96 24DC. Solidrive constant voltage 0-10V dimmable LED driver

Iconic Series ControlLink Pushbutton 41EPBM-VW PDL356PBSS-VW. Installation Instructions REGISTERED DESIGN

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

Explosion Proof C1D2 0-10V Dimmable LED Fixture - 4ft 2 Lamp - Emergency Ballast - Terminal Strips

Datasheet: K-22 LO Sensor

LED Control Solutions

FV-11VQL6. Thank you for purchasing this Panasonic product Back cover FV-15VQL6


for relative humidity and temperature

Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs

Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual

SPECIFICATIONS Compliance & Regulatory Approvals DIMMER MODELS TRIM PLATES (SOLD SEPARATELY) SYSTEM DIAGRAM. Input. Output. Environmental Requirements

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

MODEL 5100 VOTING LOGIC MODULE

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

Reflector T2 and GU10 6,000 hours

Hi-lume 3D Overview. Fluorescent Dimming Ballasts

CLS-EXP-DIM. Functional Summary. Specifications

D454.F.CE Product Guide

MODEL LUT-ATS-D (EPC-D-F-ATS) INSTALLATION ! IMPORTANT SAFEGUARDS!

2-wire Passive Intelligent Loop (LED) Display Meter

Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style V Dimmable

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

EU Declaration of Conformity Annex

MODEL EPC-D-F-ATS INSTALLATION INSTRUCTIONS ! IMPORTANT SAFEGUARDS!

EMERGENCY POWERHUBB NODE INSTALLATION AND OPERATION GUIDE

Room air quality sensors

Vive PowPak Fixture Controls

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

HLS-2C Active Hearing Loop Panel

56W Hazardous Location LED Fixture - C1D2 - Stainless Steel - Dimmable - DALI Network

3kW 6kW, QUBE Fiber Lasers

Duct Air Quality Sensors

2-wire Passive Intelligent Loop (LED) Display Meter

Motion Sensor. For Outdoor Use. Wall & ceiling mounted. Quick & Easy Installation 2 Channels

SYSTEM. field cuttable. lipleds 8200 Series

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Module de relais Relay Module. Manuel de l utilisateur 301RW. User Manual ERP /07

AC300WR 300 WATT REDUNDANT HF-20A CHASSIS POWER SUPPLY/SYSTEM MONITOR TECHNICAL MANUAL

Hi-lume 3D Overview. Fluorescent Dimming Ballasts Hi-lume 3D Architectural Dimming

TLS 600. Installation and Operation Manual. English Pages CEDES AG is certified according to ISO 9001: V 1.0.

Dimming expertise LED UNIVERSAL ROTARY DIMMER

CLARA AC Crystal CLARA AC 50. LED-modules for downlight. A qualified solution to replace and exceed Halogen solutions in Downlights.

FR-A180 FR-A360. Occupancy detector. Use

Transcription:

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER JBE LED Dimming Controller for 110V* & 220V/ 240V AC LED Systems Thank you for purchasing high quality JBE product. To ensure correct function and safety, please read and follow all instructions carefully before using the product. Please keep instructions for future reference. This DIMMER controller provides the required dim level for 110V, 220V & 240V AC lighting systems. Designed for ultimate flexibility, they allow users to easily add their own personal touch to illumination settings. Its control mode is via a 0-10V/10-0V or 1-10V so you can adjust light to the exact level of brightness you need. The product uses advanced trailing edge dimming technology to provide full control of dimmable LEDs, incandescent lighting, electronic transformer based low voltage lighting, halogen lights & heating elements as well. Temp. front label printing:

WIRING DIAGRANMS: LED DIMMER CONTROLLER SPECIFICATIONS: Item type: Dimmable LED lighting and Incandescent lighting Output: 1 channels Dimming Technique: Trailing and leading edge Connection mode: Common Neutral Static power consumption: <0.05W Minimum output Load is 10W* Operating voltage: 190V - 260V AC (50Hz). Operating voltage US: 100V - 160V AC (60Hz). Impulse length: Default values is ~100 for 50Hz Adjustable Dimming Range ~0/20-98%* 10V out (manual dimming) jumper s A & B mast On Over temperature protection Flicker and noise free. Resistant to Off-Peak Ripple Control Signal* Efficiency: > 98% typical EMI: FCC Class A Safety Compliance: is currently tested EMC Emission Compliance: is currently tested Humidity: 70-90% RH Max output current: 5A for 1200W, 8A for 2000W & 10A for 2.2KW Working temperature: -40 - +50 C Material: Polycarbonate ABS Enclosures Temp range -40 to 120 C Controller size: L115 x W90 x H60 Item weight: ~0.4Kg*

LED CONTROLLER FEATURES: Professional design for home & commercial use eg. theatres Simple brightness adjustment by means of a DC voltage. 0-10V input will accept PWM voltage from wireless dimmer. Ver1:V DC (0V=min. & 10V=max brightness Ver2: 10-0V DC (10V=min & 0V=max brightness Soft Start operation. Optically isolated adjust input (0-10V) input only. Pre-set adjustment for Low & full brightness. LEDs status indication. Long lasting durability. Fitted with suppressors to minimise radio frequency interference. Military components up 150 C. Power conditioning to protect lamps. Increase lamp life, reducing running costs. Complies with Australian and International EMC Standards. Made in Australia. Easy to install Only graph of heater and incandescent light ver1: 0V to 10V Input

ver2: 10V to 0V Input INSTALATION AMBIENT AIR TEMPERATURE FOR LED2000

Technical Requirements for Control Equipment 1. The light output of the LEDs operated by the dimmable driver is controlled via DC voltage or current applied to the control input terminal (0-10V). For external input (1-10V) mean 10V Dc (jumpers A & B On) is activated for external manual dimming 1-10 Dimmer Potentiometer. 2. The driver is intended for use with control voltages between 0 (zero) and 10 (ten) VDC or custom settings (0-5V) for BUS system. The control equipment must not impose a voltage greater than 25 volt peak maximum on the driver control terminals. 3. The two control types are current source (a theatrical dimming standard) and current sink (a dimming ballast standard). 4. There is an IEC standard for current sink controls - Standard 60929 Annex E. The standard requires that the ballast (or driver) provides full light output when the control voltage is 10 V- (or above). As the control voltage is reduced by the control, the light level is reduced. At a control voltage of 1 V-, the ballast (driver) provides its minimum light level. 5. Annex E requires the ballast (driver) to limit the current draw to 2.0 ma maximum. 6. Current sourcing controls for 0-10 V- are supported by the standard ESTA E1.3, Entertainment Technology Lighting 7. Control System 0-10 V- Analog Control Protocol. It defines 10 V- as 100% light level and 0 V- as off first option & second 10V- as 0% light & 0V- as 100%. Drivers using this protocol require the control to provide (source) the voltage 8. Minimum & maximum brightness settings. The minimum & maximum brightness level has been factory preset to suit most applications. * If you need change this please contact JBE for information. Flicker-free design: Immune to flickering due to Ripple Signal injection on mains supply (as used for off-peak hot water switching) Common Information: Delay + Soft Start: Dimmer incorporates a delay + soft start feature providing a noticeably smooth lamp illumination at turn on. This feature also minimises lamp filament start up stress, which may increase lamp life. Thermal Overload Compensation: Automatically reduces lamp brightness should the dimmer be inadvertently overloaded of overheated Resets automatically once overload conditions are corrected or dimmer cools down. Fuse Cut-Out: The unit contains fast two type fuses designed to blow or open in case of catastrophic circuit failure. This is a secondary protection measure intended to operate as a backup in case of persistent or prolonged overload conditions. If the fuse cut-out (fuse open), need to be replaced. Any significant overload should be avoided in order to prevent damage to the Dimmer.

IMPORTANT Legal Stuff Ensure all work is undertaken by a Registered Electrical trades person only. This product may not be used in any medical apparatus or other technical products that are critical for the functioning of lifesaving or supporting systems. We define these systems as such that in the case of failure may lead to the death or injury of a person. Incorporation in such a system requires the explicit written permission from JBE. Trademarks used in this document are properties Safety Notice Read and understand all safety information in this instruction. Improper installation of the product can result in electrical shock that can result in death or serious injury. If you are not qualified to install this equipment, use a qualified electrical installer. In this instruction, a WARNING box alerts you to a hazard that, if ignored, could result in death or serious personal injury. A Caution box describes a hazard that can cause minor personal injury. The attention triangle tells you about actions that can cause damage to the product or property. Improper installation of this product, or use for any purpose other than described in this instruction, can result in product failure or damage to attached equipment. Pay attention to the specifications and wiring diagrams in this document