Galletti IWC THE HYDRONIC CASSETTE UNIT PAR EXCELLENCE A guide to choosing Create value to design better

Similar documents
Galletti Hydronic indoor units

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

A NEW BEGINNING IN FAN COIL HISTORY

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

ART-U 1-4 kw. Design fan coil unit with a minimum depth of 10 cm only and BLDC motor. Fan coil ART-U PLUS. Design-driven innovation NEW

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling

Fan coil units with centrifugal fan. Fan coils with inverter BRUSHLESS motor. Fan coil units with centrifugal fan. Units for air conditioning system

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS

Galletti. FLAT fan coil units.

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

The technical and dimensional data reported in this manual may be modified in view of any product improvement.

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Futura Fan Coil Units ICIM

technical data Fan coil unit FWB small duct unit

CASSETTE UNIT. Comfort Circle

Carisma Fly. Made in. Italy. Wall-mounted Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT.

SkyStar SK. Cassette Fan Coil Unit with Asynchronous Motor

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

OMNIA RADIANT FAN COIL WITH RADIANT HEATING PANEL THE FAN COIL FEATURING 3 HEATING MODES

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

SkyStar SK-ECM. Cassette Fan Coil Unit with EC Brushless Electronic Motor and Inverter Board

Passive chilled beams

QTS SELECTION TECHNICAL BOOKLET

consumption ECM motors NEW Low energy Cassette Fan Coil Units YHK ECM YHK

Fan Coil Range HYDRONIC TERMINALS

TopVent Design Handbook

Fan coils with Inverter Brushless motor (EC) Universal and floor installation FCZI_U

TECHNICAL MANUAL FOR AIR-COOLED CONDENSING UNITS MTE

Conditioning your ambient, maximising your comfort.

SPECIFICATIONS CWC - 2P / 4P CWC 020 CWC 030 CWC 040 CWC 050 CWC 070 CWC

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit

COMFORT HYDRONIC TERMINALS

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

KPSW CONSOLE TERMINAL UNIT

The Sabiana. of Fan Coil

SIMPLICITY FULL MODULARITY?

FCX FAN COIL SILENT & EFFICIENT. Floor, ceiling & ducted installation Applicable with VMF management system, Plasmacluster filter option

NEW. SkyStar SkyStar ECM. Cassette Fan Coil Units. consumption ECM motors. Low energy. Air Conditioning ENVIRONMENTAL COMFORT

Type PWX HORIZONTAL CHASSIS TYPE WATERSIDE FANCOILS FOR CONCEALED OR EXPOSED INSTALLATIONS

Units for suspended ceilings

Technical Manual. New Water Cassette. Series BREZZA DOUBLE

Galletti Water chillers and heat pumps catalogue

Conditioning your ambient, maximising your comfort.

Fan Coil Units. Technical Data FWC-BT/BF

Cassette units Model Comfort Circle. - heating - cooling - ventilation

EEDEN technical data. Fan coil units FWV-FWL-FWM FWD FWB FWC FWF FWT

Units for suspended cei lings

NEW GREEN TECHNOLOGY

OMNIA RADIANT FAN COIL WITH RADIANT HEATING PANEL THE FAN COIL FEATURING 3 HEATING MODES

KOG LN. Low Noise Chilled Water Cassettes Models 09, 12 & to 6.10kW to 5.10kW. 330 to 920 m3/h

Blower-YEFB-020-3R-1maxVel

Optimal work climate with open doors. Industrial air curtains Model IndAC

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT

Installation Operation Maintenance. Ductable water unit FWD FWD-SVX01D-E4

COMPACT AIR HANDLING UNIT

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

UniTrane Terminals. High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line Blower coil: B-Line. Product Presentation September 2016

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

Halton CHB Active chilled beam with boost function for bulkhead installation

MORE VALUE TO YOUR WELL-BEING

Installation Operation Maintenance

SIMPLICITY OR FULL MODULARITY?

42AM. Air heaters PRODUCT SELECTION DATA

BRIZA EC 12 HYBRID. Low Water-Temperature system LOW TEMPERATURE SYSTEM / HEATING AND COOLING

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

Refrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW

EHH SERIES DRAW THROUGH FAN COILS CFM

Fan coil units with centrifugal fan

UCS UCS/M UCS/H UCS900

System architecture. Air treatment Index

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSWALL. Wall mounted fan coil units

Energy. The Energy ducted units have been designed. Heat Recovery Unit

BRISE. Super-power for heating, cooling and ventilation.

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

High wall fan coils Climmy FHW/FHW-ECM. Technical Catalogue

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG +

Centrifugal air heaters hot water or electrical supply

COMFORT APPLICATION HYDRONIC TERMINALS ELEGANCE AND DESIGN FOR YOUR RESIDENTIAL COMFORT

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

Metropolitan high output natural and powered trench heaters

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)

GHE Dehumidifiers for radiant cooling systems with heat recovery

TECHNICAL MANUAL FOR CHILLERS AND HEAT PUMPS MPE

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

AQUASNAP JUNIOR 30RHV

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Ceiling Air Conditioning Elegant

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

Series VENTS VUT R WH ЕС

Halton Rex 600 Basic R6B - Active chilled beam

QZB "Standard" comfort fan coil

OMNIA FAN COIL FOR RESIDENTIAL APPLICATIONS EXCLUSIVE DESIGN, NUMEROUS VERSIONS. Floor & ceiling installation Applicable with VMF management system

Transcription:

www.galletti.it Galletti IWC THE HYDRONIC CASSETTE UNIT PAR EXCELLENCE A guide to choosing 2012 Create value to design better

A guide to choosing The group It s 1961 and Galletti with its Jolly copper radiating plate enters the air conditioning world! Nearly half a century has gone by since then, there have been changes in the types of system and their intended use, markets and consumer demands grow and Galletti is still among the leaders in this sector. The target is to come up with the most comprehensive range of solutions for indoor hydronic units with technologies and designs that, abreast with engineering evolution, have upgraded with the precise intention of combining reliability and innovation. In conjunction with the goal of the more than 0 years history, Galletti confirmed its leadership in terms of technology in the indoor unit sector, introducing some amazing new products such as the IWC hydronic cassette units. 2 WC66000118 - Rev 00

A guide to choosing The group THE MARKET The hydronic cassette unit market has undoubtedly been the most dynamic in the indoor water unit range in recent years in the European market. With this solution we have great flexibility in terms of installation and use of spaces in service industry applications where it is normal to have solutions that take up no room on the wall and where the premises can be readied in next to no time with a high level of comfort in the summer even in particularly significant latent load situations. In a global market of more than 200 million Euros in Europe, hydronic cassette units represent almost 30% in value with even higher percentages in the central-north of the continent and about 22% in the Italian market, estimated at about 75 million globally. WC66000118 - Rev 00 3

A guide to choosing The product Description of the IWC product The new range of IWC hydronic cassette units is the result of Galletti s experience in designing and manufacturing indoor hydronic units and innovative systems as well as adjustment concepts. The Galletti IWC range stands out for the quality of and in the care taken in making all the components. It has six 1-coil models for 2- and 4 pipe systems with wire controller or infrared remote control as well as two 2-coil models for 4 pipe systems. By using two 3-way /4 connection diverting valves (4X2 kit), controlled by the adjustment system, 1-coil fan coils can be used in 4 pipe systems with obvious economic and performance benefits. Associated with the Mycomfort controllers, the IWC can be added to the ERGO air conditioning control system and work on a temperature and humidity basis. IWC may also be equipped with a Bioxigen sanitisation system for complete purification of the indoor unit and of the air let into the premises. IWC CSWX GALLETTI CSWX Compared to the previous series, the revised version is characterized by: - the capacity of the IWC 2 model extending the range to almost kw cooling to 5 kw in the 60 x 60 modules. - all 1-coil models are available with IR remote control. - only triggered by the float, the condensate drainage pump now has an alarm position that turns the whole unit OFF when the limit level is reached. - with the 4x2 kit, the 1-coil unit can be used in 4-pipe systems combining the economic advantage with increased performance in the heating phase. - the greatest advantage compared to the Galletti CSW series with a drastic 3 to 5 db noise reduction in the most models which stands the IWC proposal in a new market position. 4 WC66000118 - Rev 00

A guide to choosing The product Constructive features - The unit s bearing structure is made from galvanised steel sheet, externally and internally insulated with heat and soundproofing material. This structure houses the main components (heat exchanger, fan drive assembly and condensate drainage pump) and is designed for letting outdoor air in and distributing air to an adjacent room. Statically and dynamically balanced centrifugal fan with backward-curving blades, mounted directly on the electric motor. The blades are designed for very low-noise and efficient operation also at slow speed. 230V electric motor with thermal protection on the windings. It has 4 speeds to optimise unit performance in terms of noise and energy. High efficiency heat exchanger made with copper piping and aluminium fins, complete with air vent valves. Plastic water drip tray moulded directly inside the polystyrene air directing structure. Condensate drainage pump with a useful head of 250 mm, complete with float and a 2-level switch for controlling the level of condensate inside the tray and alarm management. Operating logic assures a lowering of fan speed when the drainage pump is working (float switch trips, first level) to facilitate the flow of condensate from the exchanger fins. Electrical components housed in an external box, consisting of the electronic board that controls the unit and a relay for pump operation. The box is located by the side of the water connections to reduce the need for installation clearance. Plastic water drip tray moulded directly inside the polystyrene air directing structure. Air intake and outlet polystyrene panel, RAL 9001 colour, preformed high density polystyrene foam air passages complete with air suction grid, a washable polypropylene filter and adjustable air outlet fins. The panel differs between the version with wire controller, where the position of the fins is adjusted manually, and the one with the IR remote control which is motorised. In addition, a set of LEDs on the front indicates unit operating status. Mandatory accessories Fluid regulating valve kit controlled by the regulating thermostat, with a choice of 2-way valves, 3-way valves/ connections and 4x2 kit, with ON/OFF or modulating motors. Accessories available Accessories coupling table 1 BTR model, cable control 1 BTR model, IR remote control 2 BTR model, cable control LED 503 control panel X X BASE MYCOMFORT control panel X X MEDIUM MYCOMFORT control panel X X LARGE MYCOMFORT control panel X X Sensor for measuring water temperature X X 2-way valve kit with 230V ON/OFF actuator X X X 2-way valve kit with 24V ON/OFF actuator X X X 2-way valve kit with modulating actuator X X X 3-way valve kit/4 connections with ON/OFF actuator X X X 3-way valve kit/4 connections with 24V ON/OFF actuator X X X 3-way valve kit/4 connections with modulating actuator (24V, 0-V signal) X X X 4X2 3-way valve kit/4 connections with 24V ON/OFF actuator X X 4X2 3-way valve kit/4 connections with 230V ON/OFF actuator X X WC66000118 - Rev 00 5

A guide to choosing Technical features Ratings and technical data of IWC fan coil units with 1 heat exchanger Model 32 42 52 Speed 1 * 2 3 4 1 * 2 3 4 1 * 2 3 4 Total cooling capacity (1) kw 1.24 2.15 2.35 2.60 1.70 3.50 4.00 4.60 2.46 3.80 4.42 5.06 Sensible cooling capacity (1) kw 0.92 1.78 2.00 2.23 1.15 2.63 3.06 3.56 1.82 2.87 3.33 3.80 Water flow (1) l/h 213 368 404 445 291 600 687 789 422 653 758 869 Pressure drop (1) kpa 3 8 9 11 3 11 14 17 7 14 18 23 Heating capacity (2) kw 1.55 2.83 3.11 3.49 1.87 4.35 4.85 5.70 3.35 5.33 6.14 6.75 Pressure drop (2) kpa 3 7 8.00 3 13 17 6 14 18 23 Heating capacity (3) kw 2.02 3.72 4.09 4.61 2.42 5.7 6.32 7.46 4.46 7.11 8.17 8.91 Water flow (3) l/h 177 325 358 403 211 498 552 652 621 714 779 619 Pressure drop (3) kpa 2 6 7 8 2 7 9 12 5 12 16 18 Water content dm3 0.43 0.86 0.86 Air flow m3/h 180 400 460 520 200 530 630 750 370 630 760 880 Power input W 17 40 50 60 20 60 70 90 26 71 85 98 Sound power level (4) db/a 30 41 44 46 32 48 51 55 41 53 57 61 Sound pressure level (5) db/a 25 36 39 41 27 43 46 50 36 48 52 56 Water connections inches 1 / 2 1 / 2 1 / 2 Dimensions H x L x P mm 273 x 575 x 575 273 x 575 x 575 273 x 575 x 575 Dimensions H x L x P mm 64 x 730 x 730 64 x 730 x 730 64 x 730 x 730 Ratings and technical data of IWC fan coil units with 1 heat exchanger Model 62 82 2 Speed 1 2 3 * 4 1 2 3 4 * 1 2 3 * 4 Total cooling capacity (1) kw 4.20 5.00 5.40 6.00 5.50 6.50 8.00 9. 6.23 8.09 8.90 9.92 Sensible cooling capacity (1) kw 3.13 3.70 3.99 4.40 4.11 5.08 6. 6.84 4.69 6.17 6.87 7.71 Water flow (1) l/h 720 859 930 1,029 944 1,116 1,373 1,561 1,070 1,389 1,529 1,702 Pressure drop (1) kpa 16 22 25 30 21 28 41 51 27 42 50 60 Heating capacity (2) kw 5.40 6.40 7. 7.70 6.28 8.52 9.42.19 7.34 9.53.59 11.69 Pressure drop (2) kpa 15 21 25 30 21 29 39 48 26 42 49 60 Heating capacity (3) kw 7.08 8.39 9.33.08 8.14 11.24 12.26 13.18 9.52 12.34 13.73 15.11 Water flow (3) l/h 619 733 815 881 711 982 1,071 1,152 832 1,079 1,200 1,321 Pressure drop (3) kpa 12 16 19 22 12 21 24 27 16 26 31 37 Water content dm3 1.00 1.50 1.50 Air flow m3/h 850 1,060 1,160 1,300 830 190 1,270 1,400 1,200 1,700 1,980 2,300 Power input W 80 90 0 120 80 0 120 140 1 130 155 180 Sound power level (4) db/a 43 48 49 51 37 46 50 53 43 49 53 57 Sound pressure level (5) db/a 38 43 44 46 32 41 45 48 38 44 48 52 Water connections inches 3 / 4 3 / 4 3 / 4 Dimensions H x L x P mm 273 x 776 x 776 290 x 66 x 776 290 x 66 x 776 Dimensions H x L x P mm 64 x 860 x 860 64 x 1150 x 860 64 x 1150 x 860 NOTES: 1 = water temperature 7/12 C, air temperature dry bulb 27 C, wet bulb 19 C 2 = inlet water temperature 50 C, water flow rate same as in cooling mode, air inlet temperature 20 C 3 = water temperature 60/50 C, air temperature 20 C 4= sound power conforming to ISO 3741 and ISO 3742 5 = Sound pressure level measured at a distance of 1 m with a directivity factor of 4 * Additional speed available from July 2012 Galletti SpA takes part in the EUROVENT Certification Programme. The products involved can be seen at www.eurovent-certification.com 6 WC66000118 - Rev 00

A guide to choosing Technical features Ratings and technical data of IWC fan coil units with 2 heat exchangers Model 34 44 Speed 1 * 2 3 4 1 * 2 3 4 Total cooling capacity (1) kw 1.03 1.72 1.88 2.05 1.52 2.88 3.28 3.76 Sensible cooling capacity (1) kw 0.81 1.51 1.66 1.82 1.07 2.27 2.60 3.00 Water flow (1) l/h 177 295 323 351 295 494 563 645 Pressure drop (1) kpa 3 8 9 11 8 11 13 17 Heating capacity (3) kw 1.1 1.78 1.95 2.2 1.48 2.87 3.14 3.76 Water flow (3) l/h 97 156 171 193 130 252 276 330 Pressure drop (3) kpa 11 25 29 36 7 22 26 36 Water content dm3 0.43 0.86 Air flow m3/h 180 400 460 520 200 530 630 750 Power input W 17 40 50 60 20 60 70 90 Sound power level (4) db/a 30 41 44 46 32 48 51 55 Sound pressure level (5) db/a 25 36 39 41 27 43 46 50 Cooling heat exchanger water connections inches 1 / 2 1 / 2 Heating heat exchanger water connections inches 1 / 2 1 / 2 Dimensions H x L x P mm 273 x 575 x 575 273 x 575 x 575 Dimensions H x L x P mm 64 x 730 x 730 64 x 730 x 730 NOTES: 1 = water temperature 7/12 C, air temperature dry bulb 27 C, wet bulb 19 C 3 = Water temperature 70-60 C; air temperature 20 C 4 = sound power conforming to ISO 3741 and ISO 3742 5 = Sound pressure level measured at a distance of 1 m with a directivity factor of 4 * Additional speed available from July 2012 Galletti SpA takes part in the EUROVENT Certification Programme. The products involved can be seen at www.eurovent-certification.com WC66000118 - Rev 00 7

A guide to choosing Overall dimensions DIMENSIONI OF 2 PIPES IWC 03-04-05 41 min. 259 Ceiling Suspension brackets 575 506 E 135 259 C 192 152 70 Suspension brackets D A 228 575 544 23 273 296 600 Suspension brackets B 600 41 730 544 Fresh air intake side 41 min. Ceiling Suspending rod 544 Nuts and washers 506 Electric control board 506 730 A B C D E Condensate hole: 18 mm Ø OD Water inlet : ½ gas female Water outlet: ½ gas femmina Coil air vent Fresh air intake: Ø 70 mm Ceiling 41 min. 259 Water connection side 4 PIPES IWC 03-04 DIMENSIONIS Suspension brackets 575 506 H 135 259 E C 192 152 70 Suspension brackets 575 544 F G A 228 23 273 296 600 Suspension brackets B D 600 41 730 544 Fresh air intake side 41 min. Ceiling Suspending rod 544 Nuts and washers 506 Electric control board 506 730 A B C D D F G H Condensate hole: 18 mm Ø OD Main heat exchanger water inlet: ½ gas female Main heat exchanger water outlet: ½ gas female Main heat exchanger water inlet: ½ gas female Main heat exchanger water inlet: ½ gas female Main heat exchanger air vent Additional heat exchanger air vent External air intake: Ø 70 mm Water connection side 8 WC66000118 - Rev 00

A guide to choosing Overall dimensions DIMENSIONI OF 2 PIPES IWC 06-08- 860 30 min IWC6 Y Z 500 L 760 30 mini CWX 6 F H 30 240 48 200 D C B A 125 X A Condensate hole: 32 mm Ø OD B Air inlet: ¾ gas female C Air outlet: ¾ gas female D Coil air vent E Electrical cable passage F Fresh air intake: mm 60 x mm 55 E MODEL L H X Y Z IWC 06 760 3 260 860 500 IWC 08-50 340 290 1150 750 WC66000118 - Rev 00 9

A guide to choosing Strong points/advantage for the customer STRONG POINT/ADVANTAGE FOR THE CUSTOMER SPECIFIC DIMENSIONING OF EACH SPEED FOR THE SUMMER AND WINTER MODES The know-how of a European leader in the production of fan coils such as Galletti and its many years experience and applications, has led to the innovative dimensioning of operating speeds in relation to market standards. In fact, the sound levels reached at minimum speed, which are the best in the market, can guarantee excellent maintenance performance in the summer mode. Differently, when heating, also when the temperature of the water in the exchanger is low, the danger of stratifications or an incorrect diffusion of the air is all too real. Therefore, the choice of an additional speed allows you to improve the compromise between environmental comfort and low-noise. STRONG POINT/ADVANTAGE FOR THE CUSTOMER HIGH QUALITY MATERIALS AND CONSTRUCTION CARE Galletti has always been convinced that an indoor hydronic unit must not just meet the requirements of designers and users in terms of technical and acoustic characteristics. The quality of the materials used, the care taken with assembly, the sturdiness and consequent long life of the fan coils are fundamental aspects in qualifying a product preference and a system where economic investments are often significant. The Galletti IWC cassette compares favourably with the most highly qualified manufacturers in the sector, offering an all-round 3-year warranty on the unit, fully aware of its much longer life and reliability over time. STRONG POINT/ADVANTAGE FOR THE CUSTOMER THE FIRST SANITISED CASSETTE IN THE MARKET For years Galletti has been using an innovative Swiss patent called BIOXIGEN for its indoor hydronic units. This exclusive and unique low voltage ioniser, thanks to the particular way it works, does not only reduce bacteria and pathogenic germs but it sanitises the indoor unit of the system 24h/day and its entire surface as well. Bioxigen is, therefore, particularly suited to applications such as: - medical centres and clinics - sports facilities - offices - public facilities www.bioxigen.com WC66000118 - Rev 00

A guide to choosing Notes WC66000118 - Rev 00 11

claudiomancinistudio.com WC66000118 - Rev 00 Via Romagnoli 12/a - 400 Bentivoglio - Bologna - Italia Tel. +39 051 89 08 111 fax +39 051 89 08 122 www.galletti.it - info@galletti.it