Ducted Split System Air Conditioners Technical Data

Similar documents
Ducted Split System Air Conditioners Technical Data

Technical Data ISD 87KYX / OSA 87RKSH. Ducted Split System Air Conditioner. 8.5 kw

Technical Data Ducted Three Phase Split System Air Conditioner

Technical Data ISD 184KY / OSA 184RKTV. Ducted Split System Air Conditioner kw

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

Technical Data ISU Series. Underceiling/Console Split System Air Conditioners kw 15 kw

Technical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging

Technical Data OPA RKTBG-P. Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

Technical Data VPA 120, 160. Ducted Vertical Packaged Air Conditioner/Heat Pump kw 16.1 kw. Wide Ambient Capabilities

MEPS COMPLIANT. Product Review OPA-RK Series. Ducted Packaged Roof Top Air Conditioners kw 137 kw. Extra Long Life Epoxy Coated Outdoor Coil

Water Cooled Units HWP 370, 445. Cooling Capacity 36.6kW kW. Heating Capacity 34.9kW kW

EC Motor Fan Coil Units. IMD-Y Series l/s

Technical Data ACN Series. Modular Air Cooled Condensers. 68 kw 155 kw. Extra Long Life Epoxy Coated Outdoor Coil. Nominal Cooling Capacity

Cooling Capacity 3.5kW kW. Heating Capacity 4.4kW kW. Air Conditioning. Giving you complete control

Packaged Air Conditioning Custom Build Solutions

Cooling Capacity 1.0kW - 8.5kW. Heating Capacity 1.0kW - 9.7kW. Hitachi. Inverter Wall Splits Air Conditioning. Giving you complete control

S Y D. HWP 35, 47, 58 (c/w EC Motor & UC7 Controller) Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

EC Motor Fan Coil Units. IMDL-Y Series l/s

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

OPA RKTG-P (ECO) Air Cooled Packaged Units - Reverse Cycle - R410A Installation & Maintenance

Cooling Capacity 3.5kW kW. Heating Capacity 4.4kW kW. eco. series. Air Conditioning. Giving you complete control

REVERSE CYCLE DUCTED SPLIT SYSTEMS (ISDL/OSA c/w UC8/IUC) Installation & Maintenance

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

ADD-ON AIR CONDITIONING CHANGING THE GAME FOR COMFORT AND PERFORMANCE

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Heat Pump Air Conditioning Systems

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

PRODUCT RANGE: ROOFTOP PACKAGE

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

Condensing Units CUS 15-60

Air Cooled Packaged Units

Hitachi Inverter Wall Split Air Conditioning

TOSHIBA AIR CONDITIONING

AQUASNAP JUNIOR 30RHV

S D HWP 77, 96. Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance. Fig. 1 Nomenclature. Fig.

Ducted inverter reverse cycle air conditioning

SAT-3 Room Temperature Controller

OPTIONAL SPRING MTG HANGING CENTRES WATER CONN'S: TWO BSP MALE. 19 mm (3/4") ELECTRICAL CONDUIT HOLES ACCESS PANEL OUT (WATER) IN 485 MOUNTING

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

Water Cooled Air Conditioners Applications Manual

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

PAJ3. Product Specifications

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

TOSHIBA AIR CONDITIONING

designed for air conditioning australian living

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Modular Air Cooled Scroll Chillers

USER'S OPERATING INSTRUCTIONS

ROOFTOP PACKAGED AIR CONDITIONERS

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

LZA High efficiency air to water heat pumps with HP compressor

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

ultimate climate control and advanced energy efficiency THE ESP SERIES

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

Commercial High-Efficiency Condensing Units

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

What do I need for my bedroom?

Remote Air Cooled Condensers C2 Series

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

MAC N-407 Air-Cooled Chiller

Multi Split Systems. Reverse Cycle, Inverter Air Conditioner. Exclusively distributed by

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

MACH N-407 Heat Pump Air-Cooled Chiller

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Q Series. Inverter Split Systems

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Braemar superior range of reverse cycle air conditioning

Concealed Ducted Split Series R-407C MBH

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

General Description. Operation

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette

TECHNICAL SPECIFICATIONS

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

Refrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW

Now with WiFi as standard Find out more at

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

MAC-120HE-03 Air-Cooled Chiller

30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG +

Transcription:

Technical Data ISDL 66, ISDL 87, ISDL 116 Cooling Capacity 6.7kW - 11.2kW Heating Capacity 6.2kW - 11.1kW

Contents ISDL 66 116 KYX SERIES 3 General 3 Applications 4 Air Flow Selection 4 Features 4 Refrigerant R410A 4 User Friendly 4 Economy 4 Efficient 4 Performance 4 Separable 5 Quiet 5 Slimline 5 Durable 5 Insulation 5 Control Option 5 Self Diagnostics 5 Zone Control 5 Optional Equipment 6 Safety Features 6 Compressor 6 Refrigeration Piping 6 Wiring 6 SAT-3 CONTROLLER (Optional) 7 Features Summary 7 PERFORMANCE DATA 8 Cooling Capacity (kw) 8 Reverse Cycle Systems / Heating Capacity (kw) Indoor Air Flow Correction Factors @ nominal conditions Air Handling 10 Sound Levels 11 Indoor Unit 11 Outdoor Unit 13 DIMENSIONS (mm) 14 ISDL Indoor Unit 14 OSA Outdoor Unit 15 SPECIFICATIONS 16 9 9 Page 2 of 17

ISDL 66-116 KYX series The ISDL indoor units, together with their associated OSA outdoor units, provide a reverse cycle (heat pump) split system air conditioner designed and developed to comply with and exceed AS/NZS 3823. Each system has been successfully tested at 52 C ambient. Page 3 of 17

ISDL 66-116 KYX series Applications These low profile units have been specifically developed for air conditioning of light commercial and residential premises, e.g. offices, motels shops and homes. AIR FLOW SELECTION If the air returning to the indoor coil is regularly expected to be above 50%RH, then the coil face velocity should be limited to be 2.5 m/s or less. High humidity levels can occur in tropical or subtropical conditions, and/or when heavily moisture laden fresh air is introduced. Consideration must always be given to selecting an air flow and face velocity that avoids water carry-over problems. Applications using full or high proportions of fresh air should be referred to your nearest temperzone sales office to establish the correct selection of units. FEATURES Refrigerant R410A Each complete system uses refrigerant R410A which has zero ozone depletion potential. User Friendly The air conditioning system is available with an optional SAT-3 or TZT-100 Controller which is wired to the Indoor or Outdoor unit. These thermostats have been designed to maintain a high level of comfort for room occupants. Emphasis has been placed on providing controls that are easy to use despite the sophisticated microprocessor system that runs it. Use of the Auto and Timer function settings allows you to set it and forget it. Efficient Indoor units include a high efficiency electronically commutated (EC) motor. Part load operation at low loads (75% airflow equates to 55% power use) using temperzone algorithms. Each outdoor unit incorporates a high efficiency compressor. Heat exchange coils use inner grooved (rifled) tube for better heat transfer. Performance The OSA 116 digital scroll compressor technology can provide close comfort control of the room temperature. A dynamically balanced forward curved fan with a multi-speed EC motor enables fine tuning of the indoor unit to match the supply air requirements. These EC motor fans have a fully integrated speed control that enables soft starting. Fan speed can be stepped to your own requirements or continuously variable using a 0 10V DC control signal. The system includes a temperature sensing head pressure control which enables the system to compensate for outdoor ambient temperatures below 20 C on cooling cycle, and above 15 C on heating cycle. Low Profile. The indoor units have a low 267 mm height making them ideal for small ceiling spaces. Quiet Each integral high efficiency EC motor can vary from zero to full speed. This allows slow ramp up with no sudden noise change. The outdoor units coil design permits low fan speeds and hence low noise levels. The compressor is isolated in a built-in, insulated compartment to minimise noise. The indoor unit is also insulated for noise attenuation. Page 4 of 17

ISDL 66, 87, 116 Slimline The compact up-right design of the outdoor units requires only a 100 mm gap on the coil side where installation is against a wall. Their slimline cabinets are particularly practical where there is restricted space, e.g. side access pathways, balconies, narrow ledges, etc. The unit is free standing, but can be fitted on a wall using the optional wall mounting brackets. Durable Both indoor and outdoor coil fins are epoxy coated for extra protection in corrosive environments, e.g. salt laden sea air. Each outdoor unit s cabinet is constructed from high grade galvanised steel - polyester powder coated (grey) for all weather protection (IP 44). External fasteners are stainless steel. Heat exchange coils comprise aluminium corrugated plate fins on mechanically expanded rifled copper tube. Each indoor unit s cabinet is constructed from high grade galvanised steel and includes a plastic drain tray for complete corrosion resistance. OSA 116 coil is protected with louvred anti-hail guards. Serviceable To enable a thorough cleanse, the indoor units drain tray is removeable. Control Option Commissioning is made easier when the EC motor to be controlled variably (within a restricted range) by a 0 10 volt DC signal that can be supplied either by a BMS system, a sophisticated controller or temperzone s optional TZT-100 Controller. Compatiblity The supply and return air spigots on the indoor unit have been designed to fit standard flexible ducting. Alternatively they can easily be removed for attaching rigid ducting. Self Diagnostics The Outdoor Unit Controller (UC8) has a LED display to indicate faults and running conditions. A non-specific fault indicator is included for interface to external systems via the optional relay board. Zone Control ISDL 116KYX versions, if supplied with SAT-3 controller, can be fitted with the optional Zone Control kit which allows up to 6 zone dampers to be switched from the SAT-3 wall control. Standard damper motors, 24 volt ac, can be used with drive open/drive close. Insulation Closed cell foam insulation has been used in the indoor units cabinet to ensure no particles are introduced into the air stream. The insulation is foil faced and meets fire test standards AS 1530.3 (1999) and BS 476 parts 6 & 7. Page 5 of 17

ISDL 66, 87, 116 OPTIONAL EQUIPMENT Outdoor Unit: 1. Wall mounting brackets. 2. Anti-vibration mounts (rubber) 3. Drain connection - right angle 4. Fault relay board (201-000-105) 5. Soft Starter for lowering starting current (OSA 116RKSG only). Indoor Unit: REFRIGERATION PIPING Maximum line length is 40m for OSA 66/87 and 60m for OSA 116. Max. height separations between units are: Outdoor unit above indoor unit: 20m Outdoor unit below indoor unit: 20m. Each OSA unit is shipped from the factory with a charge of HFC-410A (R410A) refrigerant sufficient for a 10m line length. Liquid and suction service valves are provided. The matched indoor unit is shipped with a holding charge of nitrogen. Both units have brazed pipe connections. 1. temperzone SAT-3 Controller or TZT-100 Controller. 2. Six Zone Control kit for SAT-3 (ISDL 116 only). 3. Spring mounting kit. 4. Filter - EU2/G2 rated. SAFETY FEATURES 1. HP and loss of refrigerant protection. 2. Anti-rapid cycle timer and internal overload for compressor protection. 3. Circuit breaker control circuits. 4. Time-and-temperature controlled electronic de-ice switch ensures icing up of the outdoor coil during heating cycle is kept to a minimum. WIRING The electrical supply required (including voltage fluctuation limits) is: OSA 66/87/116 RKS: 1 phase 200 252 V a.c. 50 Hz with neutral and earth. OSA 116 RKT: 3 phase 342 436 V a.c. 50 Hz with neutral and earth. A control panel, located in each outdoor unit, is fully wired ready to accept the main power supply. Each system conforms with emission standards EN 55014-1, EN 60335-1 and EN 60335-2-40. 5. Frost protection on cooling cycle. 6. Sensor fault indication. 7. Compressor minimum run time to ensure oil return. 8. 12V control circuit. COMPRESSOR Each high efficiency scroll compressor is hermetically sealed, quiet running and supported on rubber mounts to minimise vibration. Digital scroll compressors (used in OSA 116) have proven very reliable because of their design simplicity; electrical harmonic noise is very low. Page 6 of 17

SAT-3 Controller (Optional) Open Closed FEATURES SUMMARY Cool / Dry / Fan modes. Heat / Auto modes Auto / High / Medium / Low fan speed selection. (customisable). Temperature setting range from 16 C 30 C. Room temperature display. Real time clock. 7 day timer up to four start and/or stops per day Override countdown run timer; up to 4 hours. Continuous or Intermittent selection of fan run-on in dead zone. Backlit screen for ease of reading; changes colour for each mode. Soft touch tab keys Battery backup (Lithium). Sleep function improves night time comfort and saves energy. Eco mode for ecomical operation. Quiet mode for outdoor unit. Low voltage control cable. Connects to either indoor unit or outdoor unit. Colour: white and light grey (Keypad - green and blue). Optional: 1. Remote return air sensor 2. Six Zone Control kit (ISDL 116 only) Note: Not backwards compatible with units using SAT-2. Page 7 of 17

Performance Data COOLING CAPACITY (KW) Total = Total Capacity (kw). Sens. = Sensible Capacity (kw). E.A.T. = Entering Air Temperature. = Nominal Capacity (kw). See over for Indoor Air Flow Correction factors > Note: Capacities are gross and do not include allowance for fan motor heat loss. Capacities are for close coupled systems. Interconnecting pipework will reduce capacity.. Models Indoor Unit Outdoor Unit ISDL 66 OSA 66 ISDL 87 OSA 87 ISDL 116 OSA 116G Indoor Fan Speed Air l/s High 370 High 480 High 630 Indoor coil E.A.T. D.B. C W.B. C Outdoor coil entering air temperature C D.B. 23 27 31 35 39 43 Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. 21 15 6.5 5.2 6.5 5.2 6.3 5.1 6.0 4.9 5.6 4.6 5.1 4.3 23 17 6.9 5.1 6.8 5.1 6.7 5.0 6.3 4.8 6.0 4.6 5.5 4.2 27 19 7.2 5.8 7.2 5.8 7.0 5.7 6.7 5.6 6.3 5.3 5.8 4.9 31 21 7.6 6.9 7.5 6.9 7.3 6.8 7.1 6.6 6.7 6.3 6.2 5.9 21 15 8.3 6.6 8.2 6.6 8.0 6.4 7.6 6.2 7.1 5.9 6.5 5.4 23 17 8.8 6.4 8.7 6.4 8.5 6.3 8.1 6.1 7.6 5.8 6.9 5.4 27 19 9.2 7.4 9.1 7.4 8.9 7.3 8.5 7.0 8.0 6.7 7.4 6.2 31 21 9.7 8.7 9.6 8.7 9.3 8.6 9.0 8.3 8.5 8.0 7.8 7.5 21 15 11.0 8.6 10.9 8.6 10.5 8.4 10.0 8.1 9.4 7.7 8.6 7.1 23 17 11.6 8.4 11.4 8.4 11.2 8.3 10.6 8.0 10.0 7.6 9.1 7.1 27 19 12.2 9.7 12.0 9.7 11.7 9.5 11.2 9.2 10.6 8.8 9.7 8.2 31 21 12.8 11.4 12.6 11.4 12.3 11.3 11.8 10.9 11.2 10.5 10.3 9.8 Page 8 of 17

Performance Data - Reverse Cycle Systems HEATING CAPACITY (KW) G N = Gross Heating Capacity kw, based on nominal air flow. = Net Heating Capacity kw allowing for average defrost. = Nominal Capacity (kw). Models Indoor Entering Air Temp. C Outdoor coil entering air temperature C D.B. Indoor Unit Outdoor Unit D.B. -5-3 -1 1 3 5 7 9 G N. G N. G N. G N. G N. G N. G N. G N. ISDL 66 OSA 66 ISDL 87 OSA 87 ISDL 116 OSA 116G 15 4.6 4.4 4.9 4.3 5.2 4.4 5.4 4.7 5.7 5.2 6.0 6.0 6.2 6.2 6.5 6.5 20 4.6 4.3 4.8 4.3 5.1 4.3 5.4 4.6 5.6 5.2 5.9 5.9 6.2 6.2 6.4 6.4 25 4.4 4.2 4.7 4.2 5.0 4.2 5.2 4.5 5.5 5.0 5.8 5.8 6.0 6.0 6.3 6.3 15 5.9 5.6 6.2 5.5 6.6 5.6 6.9 5.9 7.3 6.6 7.6 7.6 7.9 7.9 8.3 8.3 20 5.8 5.5 6.2 5.4 6.5 5.5 6.8 5.9 7.2 6.6 7.5 7.5 7.8 7.8 8.2 8.2 25 5.6 5.4 6.0 5.3 6.3 5.4 6.7 5.7 7.0 6.4 7.3 7.3 7.7 7.7 8.0 8.0 15 8.3 7.9 8.8 7.8 9.3 7.9 9.8 8.4 10.2 9.4 10.7 10.7 11.2 11.2 11.7 11.7 20 8.2 7.8 8.7 7.7 9.2 7.8 9.6 8.3 10.1 9.3 10.6 10.6 11.1 11.1 11.5 11.5 25 8.0 7.6 8.4 7.5 8.9 7.6 9.4 8.1 9.9 9.1 10.3 10.3 10.8 10.8 11.3 11.3 INDOOR AIR FLOW CORRECTION FACTORS @ NOMINAL CONDITIONS Indoor Air Flow (%) -20-10. Rated +10 Total Capacity 0.95 0.975 1.0 1.025 Sensible Capacity 0.89 0.950 1.0 1.050 Page 9 of 17

Performance Data AIR HANDLING Airflows are for a dry coil. Supply and return air spigots fitted. Reduce airflow by 10% in high moisture removal conditions. In a free blow application, beware of exceeding indoor fan motor s full load amp limit. Refer back page for filter losses. Air flows given are for ISDL units without filter installed. ISDL 66KYX AVAILABLE EXTERNAL PRESSURE (Pa) 150 0.7A 100 0.5A 0.4A 50 0.3A 1.0A 0.3A 0 0.3A 0.5A 0.7A 0.9A 200 250 300 350 400 450 AIR FLOW (l/s) 2 m/s Face Velocity INPUT (watts) ISDL 87KYX l/s - Pa - - - - l/s - W 250 10V 200 l/s - Pa - - - - l/s - W 300 10V 250 9V 9V 150 200 8V 8V 100 150 7V 6V 7V 50 100 6V 8V 7V 6V 9V 10V AVAILABLE EXTERNAL PRESSURE (Pa) 150 100 50 0.8A 0.8A 0.7A 0.6A 8V 9V 10V 0.5A 1.0A 0 0.6A 0.7A 0.9A 300 350 400 450 500 550 AIR VOLUME (l/s) 2 m/s Face Velocity 6V 7V 1.3A INPUT (watts) ISDL 116KYX AVAILABLE EXTERNAL PRESSURE (Pa) 150 1.0A 100 0.8A 0.7A 50 0.6A l/s - Pa 8V 7V 6V 7V 10V 9V - - - - l/s - W 400 10V 300 9V 200 0.6A 0 0.7A 0.9A 1.2A 1.6A 300 400 500 600 700 800 AIR VOLUME (l/s) 2 m/s Face Velocity 6V 8V 100 INPUT (watts) Optional Filter EU2/G2 rated media (clean): Coil Face Velocity (m/s) 1.5 2.0 2.5 Pressure Loss (Pa) 5 9 13 Page 10 of 17

Performance Data SOUND LEVELS Sound Power Levels (SWL) Test Conditions: BS 848 PT2 1985. Installation Type A (free inlet and outlet). Direct method of measurement (reverberant room). Measured in decibels re 1 picowatt. INDOOR UNIT - SUPPLY AIR OUTLET OCTAVE BAND FREQUENCY Hz 125 250 500 1K 2K 4K Models FAN SPEED SWL db(a) SOUND POWER LEVELS (SWL) db 6 V 49 53 51 44 44 39 35 ISDL 66 8 V 56 60 58 52 51 47 44 10 V 62 64 63 58 57 53 49 6 V 50 54 53 47 44 40 33 ISDL 87 8 V 57 60 58 54 52 48 43 10 V 63 66 64 59 58 55 50 6 V 51 56 53 49 46 41 35 ISDL 116 8 V 57 59 59 54 53 48 43 10 V 64 65 64 62 59 55 51 SOUND PRESSURE LEVELS (SPL) WITHIN A ROOM Deduct the room absorption effect below from the Sound Power Levels (SWL) above to obtain Sound Pressure Levels within a room. Note: Occupant at least 1.5 m from sound source. OCTAVE BAND FREQUENCY Hz 125 250 500 1K 2K 4K Room type ROOM ABSORPTION EFFECT Soft 4 8 11 11 11 11 Medium 3 7 8 9 9 9 Hard 0 1 3 4 4 5 Page 11 of 17

Performance Data SOUND LEVELS Sound Power Levels (SWL) Test Conditions: BS 848 PT2 1985. Installation Type A (free inlet and outlet). Direct method of measurement (reverberant room). Measured in decibels re 1 picowatt. INDOOR UNIT - CASE BREAKOUT + RETURN AIR Models FAN SPEED SWL db(a) ISDL 66 ISDL 87 ISDL 116 OCTAVE BAND FREQUENCY Hz 125 250 500 1K 2K 4K SOUND POWER LEVELS (SWL) db 6 V 49 54 52 45 44 39 32 8 V 55 58 58 51 49 47 41 10 V 61 64 63 58 55 54 48 6 V 49 53 52 47 42 40 33 8 V 56 57 58 53 50 47 42 10 V 62 63 64 59 55 53 49 6 V 51 52 54 47 46 40 31 8 V 56 58 58 53 52 46 39 10 V 61 62 63 59 57 52 46 Page 12 of 17

Performance Data OUTDOOR UNIT OCTAVE BAND FREQUENCY Hz 125 250 500 1K 2K 4K Models FAN SPEED SWL db(a) SOUND POWER LEVELS db LOW 59 62 62 58 52 47 42 OSA 66 MED 62 63 64 61 56 51 44 HIGH 64 66 67 62 59 53 47 LOW 65 69 66 62 61 55 50 OSA 87 MED 66 70 66 63 61 56 51 HIGH 67 70 68 64 63 57 52 LOW 69 76 67 69 60 58 52 OSA 116 MED 71 79 70 71 63 58 53 HIGH 73 81 73 72 66 62 55 Sound Pressure Level (SPL) in decibels re 20 µpa. Models FAN SPEED SPL @ 3 m db(a) SOUND PRESSURE LEVELS db LOW 43 46 46 42 36 31 26 OSA 66 MED 46 47 48 45 40 35 28 HIGH 48 50 51 46 43 37 31 LOW 49 53 50 46 45 39 34 OSA 87 MED 50 54 50 47 45 40 35 HIGH 51 54 52 48 47 41 36 LOW 53 60 51 53 44 42 36 OSA 116 MED 55 63 54 55 47 42 37 HIGH 57 65 57 56 50 46 39 Page 13 of 17

Dimensions (mm) ISDL INDOOR UNIT Model A B C D Spigots* ISDL 66 1215 1117 1155 1220 250 dia.(x6) Note: Fan motor/s can be accessed from return air side or the underside. ISDL 87 1410 1320 1350 1415 250 dia.(x8) ISDL 116 1660 1540 1570 1635 250 dia.(x8) * Supply & Return Air PROJECTION ADJUSTABLE GAP FOR OPTIONAL SIDE ACCESS FILTER 820 O/A 100 100 542 W Z D OPTIONAL SPRING MTG CTRS C FIXED MTG CTRS B X Y HOLES 12 ID ELECTRICAL BOX DRAIN PIPE 19 OD 500 MIN. CLEARANCE ISDL 87KYX shown here SPIGOTS TO SUIT 250 DIA. FLEXIBLE DUCTING 267 REFRIG. CONN S Ø9.5 LIQUID Ø16 SUCTION A POINT LOAD (kg) Model W X Y Z ISDL 66 9 12 14 14 ISDL 87 11 14 17 17 ISDL 116 17 15 18 18 Drawings are NOT TO SCALE Materials and specifications are subject to change without notice due to the manufacturer s ongoing research and development programme. Page 14 of 17

Dimensions (mm) OSA OUTDOOR UNIT Model E F G H OSA 66 660 1085 714 375 OSA 87 765 1085 714 375 OSA 116 965 1120 753 398 PROJECTION 100 MIN. CLEARANCE (150 MIN. FOR OSA 116) 100 MIN. CLEARANCE (150 MIN. FOR OSA 116) 750 MIN. CLEARANCE 500 MIN. CLEARANCE ACCESS PANEL E OVERALL REFRIG. CONN S 25 DIA. ELECTRICAL CONDUIT HOLES 25 DIA. DRAIN HOLES 183 G MTG CTR 12 DIA. HOLE+SLOT F OVERALL 25 DIA. DRAIN HOLES H MTG CTR 420 OVERALL 17 POINT LOAD (kg) Model W X Y Z OSA 66 24 17 38 6 OSA 87 22 23 37 8 OSA 116 16 38 50 24 Drawings are NOT TO SCALE Materials and specifications are subject to change without notice due to the manufacturer s ongoing research and development programme. Page 15 of 17

Specifications System Indoor Unit ISDL 66KYX ISDL 87KYX ISD 116KYX Outdoor Unit OSA 66 OSA 87 OSA 116G Nominal Cooling Capacity * 1 kw 6.7 8.5 4.5~11.2 Net Cooling Capacity (MEPS)* 1 kw 6.5 8.3 10.9 EER / AEER (cooling) 3.25 / 3.20 3.33 / 3.23 3.21 / 3.19 Heating Capacity * 2 kw 6.2 7.8 4.4~11.1 COP / ACOP (heating) 3.23 / 3.20 3.45 / 3.43 3.46 / 3.44 Air Flow * 3 l/s 370 480 630 Sound Levels * 4 Indoor Unit (SWL) 56 57 57 Outdoor Unit (SPL) 48 51 57 Power Source * 5 1 phase 1 ph. or 3 phase Compressor type fixed fixed digital Indoor Fan Maximum Current A 1.5 1.5 (x2) 1.6 (x2) Running Amps (Total) OSASRKS A 9.4 11 10 OSASRKT A/ph. 7.1 / 4.5 / 4.5 Refrigerant HFC-410A (R410A) Maximum Vertical Separation m 20 20 20 Maximum Line Length m 40 40 60 Pipe Sizes (Suction/Liquid) mm OD 16 / 9.5 16 / 9.5 16 / 9.5 Controller Finish Indoor Unit Outdoor Unit Weight (net/shipping) kg IUC / UC8 zinc galvanised steel grey polyester powder coat Indoor Unit 49 / 54 58 / 78 68 / 86 Outdoor Unit 85 / 92 90 / 103 128 / 138 Notes: * 1 Nominal Cooling Capacity (gross) at AS/NZS 3823 conditions: Indoor Entering Air Temperature 27 C D.B., 19 C W.B.; Outdoor Entering Air Temperature 35 C D.B. * 2 Heating Capacity at AS/NZS 3823 conditions: Indoor Entering Air Temperature 21 C D.B.; Outdoor Entering Air Temperature 7 C D.B., 6 C W.B. * 3 Supply air flow at Nominal Cooling Capacity conditions stated above. * 4 Sound Levels are measured at nominal cooling capacity conditions stated above. SPL measured at 3m from unit. * 5 Voltage fluctuation limits: Single phase systems 200 252 V; Three phase systems 342 436 V Materials and specifications are subject to change without notice due to the manufacturer s ongoing research and development programme. Page 16 of 17

www.temperzone.biz AUCKLAND Head Office 38 Tidal Rd, Mangere, N.Z. Private Bag 93303, Otahuhu, NEW ZEALAND. Email sales@temperzone.co.nz Phone (09) 279 5250 Fax (09) 275 5637 SYDNEY Head Office 14 Carnegie Place, Blacktown, NSW 2148 PO Box 8064, Seven Hills West, NSW 2147, AUSTRALIA. Email sales@temperzone.com.au Phone (02) 8822-5700 Fax (02) 8822-5711 NEWCASTLE Phone (02) 4962-1155 Fax (02) 4961-5101 TOWNSVILLE Phone (07) 4774-3506 Fax (07) 4774-3001 WELLINGTON Phone (04) 569 3262 Fax (04) 566 6249 ADELAIDE Phone (08) 8115-2111 Fax (08) 8115-2118 LAUNCESTON Phone (03) 6331-4209 Fax (03) 6333-0224 CHRISTCHURCH Phone (03) 379 3216 Fax (03) 379 5956 MELBOURNE Phone (03) 8769-7600 Fax (03) 8769-7601 JAKARTA Phone +62 (21) 2963 4983 Fax +62 (21) 2963 4984 BRISBANE Phone (07) 3308-8333 Fax (07) 3308-8330 SINGAPORE Phone +65 6733 4292 Fax +65 6235 7180 PERTH Phone (08) 6399-5900 Fax (08) 6399-5932 SHANGHAI Phone +86 (21) 5648 2078 Available from temperzone limited 2018 04/16 Pamphlet No. 4033