FLEXIBLE NON-METALLIC COVERING FOR INDUSTRIAL INSULATION. Specially developed for use in offshore and industrial environments

Similar documents
Arma-Chek D THE DURABLE PRE-COVERED ARMAFLEX SYSTEM TO WITHSTAND MECHANICAL STRESS

FIRST-CLASS IN TRAINS

SPIDER P SPIDER P mineral

Protective & Marine Coatings Europe, Middle East, Africa & India

Armaflex Ultima.

Module 8 v1.0. Introduction to Hydrocarbon Fire Protection

..the International Leader in Thermoplastic Powders for the Protective Coating of Metals

FLAGON PVC FLAGON SV ROOFING SYNTHETIC MEMBRANES

KoolthermTM. Technical Data. HVAC & Building Services Pipe Insulation

EFFISUS BRAZE MEMBRANE

Leadax B.V. Covenant K93792/02. Leadax

Firestone Lining Systems. Dependable Performance in Demanding Environments

SYSTEM DATA SHEET Sikafloor MultiDur ES-44 ESD

Technical Checklist - Plumbing and Heating Fittings - UK Sizes

FUMEGUARD TM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED LOW SMOKE HALOGEN FREE CABLES

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

Classification report

Traction Cable Radox 3 GKW

SCREEN THERMIC. SCREEN THERMIC S2 1 % -3 % -5 % INTELLIGENT FABRICS FOR SOLAR PROTECTION INTERNAL APPLICATION

Sargasso Range. Installation manual. Sargasso S. Issue 001 January 2018 ENGLISH UK IRL SmithsEP.co.uk

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves

Coatings for protection of FRP structures with heavy rain erosion loads

Firestone EPDM Geomembrane Review of technical performances

THERMAL & ACOUSTIC INSULATION FOR RAILWAY VEHICLES

List of tests (2018)

INSTRUCTION DE IS 23 SÉCURITÉ Rev. 2 SAFETY INSTRUCTION

PERFORMANCE POLYMER SOLUTIONS

Leather descriptions and technical informations

R-KEX II with Rebars as an Anchor

See product BS EN :2010

FIRE TESTING SERVICES FIRE TESTING SER

Cable Ties JULY The electronic pdf version of this document found through is the officially binding version

FIRE TUBE Fire protection for process pipes and structural steel

SKAPS GEOTEXTILE SUBSURFACE DRAINAGE

Firestone GeoGard EPDM Review of Technical Performances

BS EN ISO : 2010

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Classification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50.

CERTIFICATE OF APPROVAL No ME 5085

HEAT SHRINK CABLE ACCESSORIES: A 40 YEARS PROVEN TECHNOLOGY FOR APPLICATIONS IN HARSH ENVIRONMENTS

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

EXTERNAL SCREEN CLASSIC NATTÉ 4503 COLLECTION INTELLIGENT FABRICS FOR SOLAR PROTECTION. Width: 250 cm

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

+ = FIRE LABORATORY INTRODUCTION. APPLUS+ LGAI - Our company history. High Technology Knowledge. Customer Confidence. Branding

Latest developments in TPO stabilization for Automotive applications ANTEC MAY 8-10 TH 2017 ANAHEIM, CA

TFI Report Classification

BS EN ISO : 2010

Information Data Sheet. Fire behavior of decorative high pressure laminates (HPL)

Plug in your cables with BLUESIL

DECLARATION OF PERFORMANCE

Geomembranes that work

SCREEN NATURE. SCREEN NATURE SCREEN NATURE INTELLIGENT FABRICS FOR SOLAR PROTECTION INTERNAL APPLICATION COLLECTION

The Key to Success with GRP Piping

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

UPONOR Ltd. Specification for UPONOR Q&E PEX Shrinkfit Plumbing Systems

Loss Prevention Standard

Market-Leading Non-Metallic Enclosure Brands

PRODUCT CATALOGUE Norröna

BS EN ISO : 2010

EXTERNAL SCREEN CLASSIC

Based in the UK, Triogen is a world leading company with over twenty years experience in the design and manufacture of specialist Ozone and UV

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Additional Reaction to Fire Classification Report

Firestone Reinforced Polypropylene (fpp-r) Geomembrane

EU RO Mutual Recognition Technical Requirements

Silquest* A-Link* 597

DECLARATION OF PERFORMANCE

Durability of the Reaction to Fire Performance for FRT Wood Products in Different End Use Applications A Ten Years Report

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

LiteEarth Advanced Synthetic Grass Geomembrane Liner INDEPENDENT THIRD PARTY PERFORMANCE TESTING REPORT. U.S. Patent No.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SCREEN DESIGN M-SCREEN 8501 COLLECTION INTELLIGENT FABRICS FOR SOLAR PROTECTION. Widths: Up to 320 cm

EN :2012 EN :2012 ETAG 026 part 3:2011 DECLARATION OF PERFORMANCE. Sikasil -670 Fire

Energy Division. Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series

CONTINUOUS GEOMEMBRANES FOR ON SITE APPLICATION. PDA Europe 2012 Annual Conference Istanbul, November

FIREPRO FIRESTOPPING AND PENETRATION SEALS PRODUCT GUIDE

NATIONAL AND INTERNATIONAL STANDARDIZATION ACTIVITIES- RUBBER Shri. Chandrakesh Singh Scientist C Petroleum, Coal & Related Products Department

Product Data Sheet. Astro Strip

Fire Protection. Intumescent fire and smoke seals for door assemblies

Annex of the certificate (Page 1/5) Accreditation Scope

Next Generation Coatings Update on Engineered Siloxane Hybrid Coatings

Photovoltaic Cables EN H1Z2Z2-K

JAS-ANZ IS : IS : 447 IS : I I CM/L: CM/L: CM/L:

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

DNVGL-CP-0399 Edition March 2016

Fire Protection Industry

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Agriculture Cultivation protection

Product Aftercare Guide

DECLARATION OF PERFORMANCE

TROsiFOl UV+ english

Introducing Solar Identification Labels

NEW. Fifty Years of Progress

Why Passive Fire Protection of Critical Controls? Why K-Mass? Why Thermal Designs, Inc.?

maximise the sun s energy with warmflow solar Warmflow Solar

ATUM: General Purpose Thin Wall Tubing - with Adhesive (Black) Medium Wall: MWTM: General Purpose Medium Wall Tubing

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

NEWSPAPER & MAGAZIN INKS. (TOYO Printing Inks Web Offset Inks)

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

TEST REPORT No PS/OO3/07

Transcription:

Arma-Chek R FLEXIBLE NON-METALLIC COVERING FOR INDUSTRIAL INSULATION Flexible polymeric covering formulated with CSM (CSPE) with combined acoustic barrier performance, ISO 15665 compliant Excellent mechanical and weathering protection Specially developed for use in offshore and industrial environments Reduces the risk of corrosion under insulation (CUI) Resistant to UV, salt water and chemicals In-built water vapour barrier μ>50.000 Works in harmony with ArmaFlex, expanding and contracting as required IMO certified

RANGE COVERING MASTIC RECOMMENDED PRODUCTS For a complete installation ArmaFlex HT625 adhesive ArmaFlex Cleaner

TECHNICAL DATA Arma-Chek R is a flexible covering system for elastomeric and other insulation materials. Especially developed for use in offshore and industrial environments. Material type Colour Applications Assembly Special Features Flexible polymer based rubber formulated with Chlorosulphonated Monomer (CSPE). Grey Protection of insulated pipework, fittings, vessels and equipment in Offshore, heavy industry, chemical and petrochemical environments which need protection against damage in situations of high mechanical stress. The ArmaFlex and Arma-Chek installation manuals should be consulted before assembly. Please consult our Customer Service Centre. Exceptional resistance to UV attack, salt water and mechanical impact. Reduces the risk of Corrosion Under Insulation (CUI). Excellent acoustic performance with natural dampening properties to reduce re-radiation effects. Property Value/Assessment Standards & Remarks Temperature Range Max service temperature +100 C (For temperatures above +100 C & below -50 C Min service temperature -50 C please contact our technical department) Thermal Conductivity Depends on the Armaflex substrate used. Water Vapour Diffusion Resistance μ 50,000 per m inch 0003 Tested acc.to EN 2086 & ASTM E96 Procedure A Fire performance Reaction to fire Fire class Part 2 & Part 5 (IMO 2010 FTP Code) ASTM E 84 BS 476 Part 6 & 7 NFP 92-507 Other technical features Euroclass B-s3,d0 Pass Class A (< 25 flame spread index) Class 0 & Class 1 M1 Calssified acc.to EN 13501-1 Tested acc. to EN 13823 & EN ISO 11925-2 IMO Approved by DNV & Bureau Veritas Density 1650-1750 kgm 3 Tear strengh > 7 N/mm Tested acc. to ISO 31-1 Tensile strengh > 5 MPa Tested acc. to ISO 37 Resistance to mechanical impact Good Elongation > 200% Tested acc. to ISO 37 Exposure UV resistant, Ozone resistant UV resistance assessed acc. to Allunga Exposure Lab

COVERING (ROLLS) Colour - Grey Code Thickness (mm) Width (mm) Length (m) m 2 roll RCS-R10/2-07-GY 2 700 10 7 RCS-R20/1-07-GY 1 700 20 14 MASTIC Code Description Pieces/carton ACH-MASTICS ADH-HT625/1,0 CLEANER/1,0 Sealing compound for installing Arma-Chek R, Cartridge 290 ml Armaflex HT625 one-component adhesive, 1,0 litre cans Special cleaner for use with Armaflex 520 Adhesive and Armaflex HT625 Adhesive. 12 12 4

PROJECT BP Clair Ridge Oil Platform North Sea PRODUCTS USED Arma-Chek R HT/ArmaFlex Industrial

UK & Ireland team Always at your service JAMIE BOMBER National Sales Manager e: jamie.bomber@armacell.com t. 07768 068 547 Northern Ireland Cumbria Republic of Ireland JOHN BRADLEY Regional Sales Manager e: john.bradley@armacell.com t. 07768 068 549 JAY DAVEY Regional Sales Manager e: jay.davey@armacell.com t. 07768 068 546 GER COYNE Ireland Sales agent e: gmpcoyne@eircom.net t. +353 872 580597 McCAIG COLLIM LTD Northern Ireland Sales Agent e: sales@mccaig-collim.co.uk t: 028 9077 7788 JASON JEENES Application Specialist e: jason.jeenes@armacell.com t. 07590 444 711 TOM MERTON Technical Specialist e: tom.merton@armacell.com t: 0161 287 7038 CUSTOMER SERVICES TEAM CLARE OLDHAM Customer Services Manager t: 0161 287 7106 e: clare.oldham@armacell.com JONATHAN GRAY Customer Services Team Leader t: 0161 287 7153 e: jonathan.gray@armacell.com JOANNE DALEY Customer Services Coordinator - North & Ireland t: 0161 287 7016 e: joanne.daley@armacell.com EMMA ROBERTS-LOMAS Customer Services Coordinator - Central t:0161 287 7103 e: emma.roberts-lomas@armacell.com KATHY SALT Customer Services Coordinator - South t: 0161 287 7102 e: kathy.salt@armacell.com GEORGINA NUTTALL Customer Services Coordinator t: 0161 287 7101 e: georgina.nuttall@armacell.com Armacell UK, Mars Street, Oldham, OL9 6LY T: 0161 287 7100 F: 0161 633 2685 E: info.uk@armacell.com W: armacell.co.uk 00074 UK Armacell PriceList 062018 UK EN