Ventless Operation Supplement GBF-D-VH

Similar documents
Operations & Service Manual

Operations & Service Manual

Operations & Service Manual

VENTLESS EXHAUST HOOD OPERATORS MANUAL AND PARTS LIST REV. MAY 2016

Operations and Service Manual

EVALUATION SUBJECT: GILES RECIRCULATING (VENTLESS) HOODS

Types of Detection. Fusible Link Detection - Most Common

PARTS LIST PL503 WVF-886 VENTLESS FRYER WITH OR WITHOUT ROLL WARMER CONTENTS

for FRYER MODELS WVAE_30F WVPE-30F WVAE-55F WVAE-55FS SUPPLEMENTAL SERVICE INSTRUCTIONS VENTILATOR HOOD SECTION

Service Bulletin No. 2930

PARTS LIST. SERVICE PARTS LIST WVG-136 Ventless Griddle with or without Roll Warmer CONTENTS

*** Inspection *** Please identify yourself as a Cintas representative when arriving onsite.

Kitchen Fire Suppression Systems Post-Event Analysis

The D1000. Typical Specifications: activate the mechanical fire suppression system. (pressurized potassium citrate / potassium acetate mix)

INSTALLATION GUIDE Steamer Module

INSTALLATION GUIDE Fryer Module

Installation Instructions

The D1000. Typical Specifications: Standard Options*: Model: D1036-F Spec & Submittal Version 2.2 D1000-F_ D1000-F_-NFPA101

FR 2 Frymaster Fryer

Pocket Hardmount. Preventative Maintenance.

The D1000. Typical Specifications: Standard Options*: Model: D1030-R Spec & Submittal Version 2.1 D1000-R_ D1000-R_-NFPA101

FR 6 Frymaster. Controller Model M4000. Model BIGLA30-T

Control Panel For Water Wash Hoods AM2

ANSUL AUTOMAN II-C EXPLOSION PROOF RELEASING DEVICE Installation, Operation, and Maintenance Manual

READ AND SAVE THESE INSTRUCTIONS WARNING! TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS OBSERVE THE FOLLOWING:

COPPER INSERT INSTALLATION INSTRUCTIONS, USE AND CARE GUIDE

The D1000. Typical Specifications: Standard Options*: Model: D1030-I_-DF Spec & Submittal Version 2.3 D1000-I_-DF D1000-I_-DF-NFPA101

KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

Fountain Classic. Installation and Owner s Manual. Page 16

Project Name: Project Address: Installer Name: Installer Address: Date of Inspection:

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

Ventless Hoods For Rotisseries. SERIES: VGH Operation Manual

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

GAS RACK OVENS WITH ELECTRONIC OVEN CONTROL

TECHNICAL INFORMATION Touchtronic Clothes Dryers

ANSUL ANSUL AUTOMAN II-C RELEASING DEVICE

WARNINGS: Must be followed carefully to avoid personal injury. IMPORTANT: Must be followed carefully to avoid damage or incorrect installation.

PRO VENTILATION HOOD USE AND CARE GUIDE CLEANING, MAINTENANCE, AND MORE

JADE RANGE LOG BROILER MODELS: JLB SERIES

New Construction Fire Inspection Process

DH200PL Intelligent Air Duct Smoke Detector with Extended Air Speed Range

CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE 06E Series Model 06E Series Model RANGE HOOD LOCATION 1. The range hood must be installed just above the

Installation, Operation, and Maintenance Manual RTE14S & RTE14S-2. For the Taco Bell "Rethermalizer" Model Numbers

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Model LF-310 Air Operated

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

Wax Base Heater & Dispenser

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O Ultra Series Range Hoods

Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien

Service & Testing Manual. Series. 20 Denlar Dr. Chester, CT (860) Fax: (860)

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Trade-Wind Professional Series Liners

INSTALLATION AND MAINTENANCE

BX600. CLASSIC ColleCtion. Specifications. Model Colour Venting Size. Air Flow Volume: Electrical Consumption:

Sanitise Syrup Lines & Valves. Taylor PH61 Cleaning every 14 days

690 and Power Fishing Systems

3500 SERIES CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

CATALOG OF REPLACEMENT PARTS HSROG SERIES SINGLE RACK OVEN. A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO

Eliminator Series. SE400E and SE800E ELECTRONIC AIR PURIFICATION SYSTEM. Electrostatic Precipitators for Commercial Applications

Fire Suppression Installation (R-102) for AVI Hoods & XLT Ovens

WIDE AREA VACUUM MODEL PF2030 WARNING: OPERATOR MUST READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THIS EQUIPMENT.

690 Power Fishing System


D350PL INTELLIGENT PHOTOELECTRONIC DUCT SMOKE DETECTOR WITH EXTENDED AIR SPEED RANGE INSTALLATION AND MAINTENANCE INSTRUCTIONS

TECHNICAL MANUAL TRAY DRYER

Agent Tanks PCL PCL PCL PCL - 600

FIre Extinguishers. K-GUARD Wet Chemical Fire Extinguishers Manual INSTALLATION 2014-DEC-29 REV. 03 PAGE 1 EXTINGUISHERS

Use, Care, and Installation Guide

TRAINING BULLETIN TOOLS 1 May 27, 2011 PRESSURIZED WATER EXTINGUISHER

Disposal Unit (BKSDU) Burger King Shortening. Operation, Service & Parts Manual BURGER KING BKSDU

Owner and Maintenance Guide Models Equipped with K250 Blower

OWNER S MANUAL FOR ELECTRIC FRYERS. Model Numbers PARAFRYER (240V) ELECTRIC FRYER

XPS-ProDry User s Guide Dryer Base

ULTRA SILENT VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS WARNING CLEANING & MAINTENANCE OPERATION CAUTION!

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

TECHNICAL INFORMATION T 15xx Dryers

Integrated Ventilation System

CL64T INDUSTRIAL TOTE WASHER

ISLAND MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

Cooker Hood User Manual

Minor Home Repairs. November 4, County of Henrico Department of Community Revitalization

EZ CLEAN IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. External Aquarium Filter

Welcome! Today s topic: Small Home Repairs. November 14, 2015

CL44eR DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE. Item # Quantity C.S.I.

Section 1 - Safety Information Section 2 - Installation: Wall Mount Hoods Section 3 - Installation: Island Mount Hoods

GREASE INTERCEPTORS. Z1192 GREASE RECOVERY APPLIANCE (GRA) INSTALLATION and OPERATION INSTRUCTIONS

Technical Manual. VFD / Cabinet Heater Upgrade 110 VAC Heater to 12 VDC Heater. Provided by: Chart Inc.

AG Series Electric Heaters

UNDER CABINET RANGE HOOD. This manual is made with 100 % recycled paper.

Installation Instructions

CORE Protection Fire System Specification

REPLACEMENT PARTS LIST

Models FFG-10 and MTI-10 Operator's Manual

Owner s Manual PS-200

MALIBU STAR OWNER S MANUAL

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

READ AND SAVE THESE INSTRUCTIONS. SE400E & SE800E Smoke Eliminator. TRION

User s Manual RA-3030SS RA-3036SS. NOTE: This unit was designed for indoor residential use and DUCTED operation only.

TABLE OF CONTENTS HOW AIRBORNE CONTAMINATION IS REMOVED 3 DIMENSIONS 4 SPECIFICATIONS 6 PLANNING THE INSTALLATION 7 ASSEMBLY & INSTALLATION 10

Transcription:

Operations & Service Manual GBF-5D-VH GBF-50D-VH Ventless Operation Supplement GBF-D-VH Giles Enterprises, Inc. An ISO900 Registered Company Committed to Quality 750 Gunter Park Drive West Montgomery, AL 609 USA Fax: () 9-7 www.gfse.com E-mail: services@gfse.com Phone Toll Free: 800.55.57 (USA & Canada Only) Form No. 65686-S (Released: 8//; Rev. A)

Installation Model: GBF-5D-VH, GBF-50D-VH. Installation This section provides a summary of the procedures necessary for proper installation of your Giles equipment, Model GBF-50D-VH, GBF-5D-VH. To prevent possible personal injury or damage to equipment, please ensure the following steps are taken.. Location Note: Consider that, when operating, the decibel level of the hood unit is approximately 65 db s.. Depending on local code, room size and other appliances in use, exhaust ventilation may be required for the space in which this unit is to be located. This often can be accomplished by installation of an exhaust fan. To determine the requirement for a specific installation, provide an HVAC contactor or specialist the following information: a. The recirculating hood exhausts between 50 to 680 cfm. b. The average temperature of the air being exhausted from the hood is approximately 90 F ( C), after four () hours of continuous cooking operations.. This appliance is to be installed, used and maintained in accordance with the Standard for Ventilation Control, and Fire Protection of Commercial Cooking Operations, NFPA 96-99. The above steps will help ensure safe and proper installation. If there are questions concerning these procedures, contact the nearest Giles Representative or other qualified service agency.

Model: GBF-5-VH, GBF-50D-VH Installation. Ventless Hood Clearances The GBF Ventless Hood Fryer series is equipped with a directional exhaust air discharge diverter which directs air horizontally to the sides and rear. For that reason, zero (0 ) clearance is required from the top of the exhaust diverter to the ceiling. A clearance of to 6 (76 to 5 cm) is recommended to allow for floor irregularities and to provide ample head space for moving or repositioning the appliance.. Ventless Hood Fire Suppression System The fire suppression system used in the Giles Ventless Hood Fryer is an Ansul R-0 Restaurant Fire Suppression System (Standard UL 97 Listed). The system consist of piping, discharge nozzles (appliance & plenum), conduit for fusible link cabling, release mechanism and empty chemical suppressant tank. Final installation, charging and testing of the system must be performed by an authorized Ansul distributor in accordance with the system s listing... cost of this work is the sole responsiblity of the purchaser. The fire suppression system is UL listed to automatically provide fire protection for cooking appliances, such as fryers, hours per day.. Fusible Link & Gas Cartridge Locations Fusible Link, 65 F Supplied & Installed by Ansul Fusible Link, 86 F Factory Installed Fusible Link 5 F Supplied & Installed by Ansul LT-0 R Cartridge Supplied & Installed by Ansul

Installation Model: GBF-5D-VH, GBF5D-VH.5 Fire Extinguisher Nozzle & Tank Locations All of the discharge nozzles have been factory installed and aligned in the proper operating position. DO NOT MOVE OR ADJUST. Plenum Nozzle Giles P/N 66 Plenum Nozzle Giles P/N 66 Appliance Nozzles () Giles P/N 66 Appliance Nozzle Giles P/N 66 Tank, -/ Gallon Giles P/N 08 Shipped with Unit, Filled & installed by Ansul

Model: GBF-5D-VH, GBF-50D-VH Installation.6 Fire Alarm Connection This connection ties the Fire Suppression System s release mechanism into a facility fire alarm system, allowing a signal to be sent to the alarm should the Hood Fire Extinguisher System be activated. Fire Alarm Connection:. Remove Cover from Fire Alarm Junction Box atop Hood. Route appropriate size conduit and wire from the Box to the facility s alarm system control box. Allow enough conduit slack so the Hood can be accessed for cleaning and servicing.. Make appropriate connections and reinstall junction box cover. Fire Alarm System Control Box Fire Alarm Junction Box 5

Ventless Hood Operation Model: GBF-5D-VH, GBF-50D-VH. Ventless Hood This section applies to the Ventless Hood (VH) models only. It describes the operation and maintenance of the Ventless Hood and the Filters contained in the hood.. Hood Operation This section describes how to start the Ventless Hood. Make use all the Filters are in place before operating the unit.. Place the Power Switch in the ON position, (if ILS, press and hold the Push and Hold to Start* button for 5 seconds) the Power Light and EAC ON indicator light will come on. If equipped with UV option, the Sight Window ** will illuminate. This will turn the unit on and the ventless hood fan will begin running. ** * Not Shown ** UV Only. Filters This section describes each Filter in the Ventless Hood... Ventless Hood Filter Table Filter When to clean or replace How to remove How to clean How to install Baffle Filter Clean Daily Section7-.0 Section 7-0.05 Section 7-0.0 EAC Filter Clean Daily Section 7-0.06 Section 7-0.09 Section 7-0.07 6 Charcoal Filter Ultra Violet Lamp Replace every 0 days, P/N 08 Clean every 0 days Replace annually Section 7-0.0 Never clean, only replace Section 7-0. Section 7-0.5 Section 7-0. Section 7-0.6

Model: GBF-5D-VH, GBF-50D-VH Ventless Hood Operation.. Baffle Filter Removal BAFFLE FILTER BAFFLE FILTER BAFFLE FILTER BAFFLE FILTER 7

Ventless Hood Operation Model: GBF-5D-VH, GBF-50D-VH.. Baffle Filter Installation BAFFLE FILTER BAFFLE FILTER BAFFLE FILTER BAFFLE FILTER Switch arm must be actuated by the Baffle Filter as shown 8

Model: GBF-5D-VH, GBF-50D-VH Ventless Hood Operation.. Baffle Filter Missing If the Baffle Filter is missing or not positioned correctly the Filter Missing Light will come on. See Section.., Baffle Filter Installation...5 Baffle Filter Cleaning The Baffle Filter should be cleaned daily. Place the Baffle Filter in a sink and clean with a mild degreaser. Dry thoroughly, then reinstall in the unit. Never place wet filter into unit!..6 EAC Filter Removal EAC EAC 9

Ventless Hood Operation Model: GBF-5D-VH, GBF-50D-VH..7 EAC Filter Installation Filter must align with this pin EAC EAC EAC Air Flow Arrow must point upward..8 EAC Filter Status The three indicator lights on the Control Panel display the status of the EAC Filter. ON The EAC Filter is in place, powered and operating normally. WASH The EAC Filter has become excessively dirty and must be cleaned. If this light is on for more than minutes, an intermittent alarm will sound and Fryer heating elements will be shutdown until the condition is remedied. CHECK The EAC Filter has stopped operating, it is either not getting a proper electrical supply or it has been damaged. If this light is on for more than minutes an intermittent alarm will sound and Fryer heating elements will be shutdown until the condition is remedied. 0

Model: GBF-5D-VH, GBF-50D-VH Ventless Hood Operation..9 EAC Filter Cleaning To ensure proper operation, the EAC Filter must be cleaned daily. Be careful not to bend the collection fins or break the ionizer wires on the EAC cell as this will prevent the filter from working properly and will cause power to the fryer heating elements to be shutdown.. Add approx. / gal of a mild degreaser, such as Simple Green or Clean Magic, to the included Soak Tank. Fill with cold water, to the full line marked by X s on inside of tank back, and mix.. Holding the contact plate of the EAC, slowly lower the filter into the Soak Tank solution.. After allowing the EAC to soak at least 0 minutes, grasp the contact plate and jog the cell up and down approximately to to help remove the grease residue.. Slowly remove the EAC from the tank and rinse clean in a sink using hot water spray. 5. Allow the EAC to thoroughly dry...0 Charcoal Filter Removal CHARCOAL CHARCOAL

Ventless Hood Operation Model: GBF-5D-VH, GBF-50D-VH.. Charcoal Filter Installation Switch must be actuated by the filter CHARCOAL CHARCOAL.-. Charcoal Filter Missing If the Charcoal Filter is missing or not positioned correctly and the unit is on, the Filter Missing Light will turn on. See Section.., Charcoal Filter Installation. 7.. Charcoal Filter Replacement Never attempt to clean the Charcoal Filter. Doing so could cause damage to the unit. Replace the Charcoal Filter every 0 days to maintain proper operation. Use Replacement Part No. 08.

Model: GBF-5D-VH, GBF-50D-VH Ventless Hood Operation.. Ultra Violet Lamp Cleaning (if equipped) CAUTION DO NOT touch or handle UV Lamp with bare hands. Doing so will greatly reduce the life of bulb. Clean UV Lamp at least every 0 days.... Place Fryer power switch in OFF position.. Remove Filter Access Cover. Remove thumb screws and Lamp Guard. There is no need to remove the lamp.. Lightly spray a mild, non-caustic, biodegradable degreaser (such as Simple Green) onto the UV lamp and use a dry, lint-free cloth to clean bulb. Avoid touching bulb with bare hands. 5. Re-install Lamp Guard and Filter Access Cover...5 Ultra Violet Lamp Removal (if equipped). Place Fryer power switch in the OFF position.. Remove Filter Access Cover.. Disconnect UV Lamp wiring harness from power supply wiring harness.. Remove thumb screws and UV Lamp Guard. 5. Remove Lamp from Holding Brackets 5. 5

Ventless Hood Operation Model: GBF-5D-VH, GBF-50D-VH..6 Ultra Violet Lamp Installation. Install new UV lamp in holding brackets.. Install Lamp Guard and tighten thumb screws.. Connect UV Lamp wiring harness to power supply wiring harness.. Install all filters and Access Cover. 5. Place Fryer power switch in the ON position...7 Hood Filter Alarm Chart Alarm Sound What will happen Filter Affected Cause Solution Reference Continuous tone Alarm will sound and power to the Fryer heating elements will shut off. (If ILS Model, power to the Fryer and the Hood section will shut off) Charcoal Filter dirty Replace Filter Sections..0 &.. Continuous tone Alarm will sound and power to the Fryer heating elements will shut off. (If ILS Model, power to the Fryer and Hood section will shut off) Baffle Filter dirty Clean Filter Sections.. & 7.. Intermittent tone Alarm will sound for two () minutes, then power to the Fryer heating elements will shut off. (If ILS Model, power to the Fryer and Hood section will shut off) E.A.C. Filter dirty Clean Filter Sections..6,..7,..8 &..9

Model: GBF-5D-VH, GBF-50D-VH Ventless Hood Operation. Maintenance This Section describes Ventless Hood (VH) System periodic maintenance procedures that will help maintain its efficiency over time. A Maintenance and Service Log is provided in this manual, see Table..6... Monthly Interlock Check The Giles Ventless Hood System is equipped with various interlocks that prevent use of the fryer in the event that conditions for safe and effective operation are not present. Testing of the interlock system should be conducted MONTHLY to ensure that it remains working properly. Check-off Service Log for tests performed. If a problem is found call a Giles Service Agent or Technical Support at 800.55.57.. Baffle Filter Check: Power Switch in the OFF position... remove the grease baffle filter. Place Power Switch in the ON position... place the Selector Switch in the COOK position. The heat light should not come on. Return power switch and selector switch to OFF and reinstall the grease baffle filter in the hood.. EAC Filter Check: Remove the EAC cell. Place Power Switch in the ON position... place the Selector Switch in the OFF (centered) position. After approx. two () minutes and when alarm tone silences, place Selector Switch to the COOK position. The heat light should not come on. Return power switch and selector switch to OFF and reinstall the EAC cell.. Charcoal Filter Check: Remove the Charcoal Filter. Place Power Switch in the ON position... place the Selector Switch in the COOK position. The heat light should not come on. Return power switch and selector switch to OFF. Reinstall the charcoal filter.. Filter Clogged Check: Perform this test ONLY when oil is in the fry pot. Place the Power Switch in the ON position and the Selector Switch in the COOK position. Place a piece of material, such as cardboard, which is large enough to block the Baffle Filter over it. Within a few seconds an alarm tone should sound and the heat light will turn off. Return all switches to their OFF positions and discard the test blockage material... Quarterly Hood Cleaning Remove power from the unit at the wall breaker. Remove all Filters from the hood. Used a mild degreaser to clean the entire hood plenum and blower sections. Be certain to clean the fan blades if there is evidence of grease build-up. The hood should section should be cleaned at least every months to help maintain performance, effectiveness and safety.. 5

Ventless Hood Operation Model: GBF-5D-VH, GBF-50D-VH.. Semi-Annual Fire Suppression System Service of the fire suppression system is to be conducted by certified fire protection equipment specialists. At a minimum, field inspection of the Fire Suppression System must be performed semi-annually by a qualified fire protection equipment service agent. This semi-annual inspection and service shall consist of the following. Place fire extinguishing system locking bar on fire system when servicing hood.. Remove charging cartridge, inspect gasket for cuts and elasticity, coat gasket with high-temperature grease... reinstall cartridge.. Verify suppressant chemical is at proper level in tank... clean o-ring and coat with high-temperature grease and reinstall.. Check and clean all discharge nozzles of any grease buildup... verify nozzle protective covers are in good condition.. Test the remote manual pull station for activation and wear. 5. Install test link and conduct simulated automatic actuation test. 6. Clean and inspect fusible links. 7. Inspect fusible link cabling for wear at pulleys and detectors... replace if necessary. 8. Record date of inspection and service... maintain in a permanent file... Annual Fire Suppression System This is the same inspection and service as the semi-annual check, except that all fusible links must be replaced with new links...5 Year Fire Suppression System Same as annual service except for the following:. Replace R-0 fire suppressant chemical.. Hydrostatically test the storage tank and discharge cartridge (replace with new parts that carry current certifications).. Perform flow test on the system regulator. 6

Model: GBF-5D-VH, GBF-50D-VH Ventless Hood Operation..6 Maintenance & Service Log Check Initial/Date Check Initial/Date ABC //0 5 5 6* 5 5 6* 7* 5 5 6* 5 5 6* 7* 5 5 6* 5 5 5 5 5 6* 7* 7 Baffle Filter Check Filter Clogged 5 EAC Filter Check Quarterly Cleaning Fire Suppression System replace Fusible Links 5 5 6* 5 8 5 6* 7* 8 5 5 6* 5 8 5 6* 7* 8 5 5 6* 5 8 5 6* 7* 8 * Inspection performed by a qualified fire equipment company. 6 Charcoal Filter Check Fire Suppression System 8 Replace UV Lamp (UV Option Only) 7

Parts List Model: GBF-5D-VH, GBF-50D-VH. Front Ventless Hood **9 * *6 *5 7 * 8 * Not shown ** UV Only 8

Parts List Model: GBF-5D-VH, GBF-50D-VH. Front Ventless Hood Item Part Number Qty. Description * 905 FILTER ACCESS PANEL, ASSY ** 906 FILTER ACCESS PANEL, ASSY, UV HOOD 08 CHARCOAL FILTER ASSY, 0 x -/8 x 050 EAC FILTER, 0 00 BAFFLE FILTER, 0 X 0 X *5 00 SWITCH, SNAP ACTION, ROLLER TYPE *6 5 EAC CONTACT BOARD 7 006 GREASE DRIP CUP 8 750 DRIP CUP SAFETY PIN **9 906 UV LAMP ASSY, 6, REPLACEMENT ONLY * Not shown ** UV Only 9

Model: GBF-5D-VH, GBF-50D-VH Parts List. Rear Ventless Hood 5 ***7 * * *8 6 7 8 **5 **6 9 0 * Not shown ** Not shown, ILS only *** UV Only 0

Parts List Model: GBF-5D-VH, GBF-50D-VH. Rear Ventless Hood Item Part Number Qty. Description 08 S/S ANSUL TANK, -/ GAL * 778 SWITCH, SIDE ROTARY, 0V, 0A, W/O ARM * 779 ACTUATOR ARM ADAPTER 589 BLOWER ASSEMBLY 5 65 FIRE DAMPER, 0 X 0 (85 F LINK) 6 7 SWITCH, PLUNGER, 50V, 5A 7 090 VACUUM SWTICH, ADJUSTABLE 8 000 SWITCH, SHUTDOWN & ALARM, 5A, 0V, ANSUL 9 0 BRACKET & RELEASE MECHANISM, ANSUL 0 776 ALARM & SHUTDOWN MODULE, AIR FILTER 08 EAC POWER SUPPLY, W/DRIVER, 08-0V 75 TERMINAL BLOCK 78 SONALERT, 50V, CONTINOUS TONE 950 SONALERT, 50V, INTERMITTENT TONE **5 08 RELAY, 0 VAC, 0A **6 0 BASE, RELAY, PLUG-IN, DIN MOUNT ***7 07 UV-LAMP ASSEMBLY (BALLAST & LAMP) *8 9005 ACTUATOR ARM, BAFFLE SWITCH * Not shown ** Not shown, ILS only *** UV Only