VST Series. INAIL approved and calibrated safety valves. Technical Data Sheet. WattsIndustries.com

Similar documents
Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

Series 1140 and 1141 Temperature Regulators

CALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

TEMPERATURE CONTROLLERS

1592P01. for liquids in piping DN

THERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE PRODUCTION RANGE IRON PIPE CODE CONNECTION

ACCREDITED. Product range Code A2L Pre-assembled set point temperature regulating unit with manifolds and box, with UPM3 Auto L pump

teide termo plus+ HEATING SERIES SCOPE THERMOSTATIC VALVES SERVICE CONDITIONS COMPONENTS TECHNICAL SHEET 07/2017 IP20060 PAG. 1/9

F900 SERIES GAS CHARGRILL G9440, G9460, G9490, G User, installation and servicing instructions T Read these instructions before use

DEVIATING VALVES ART K063

Flush individual room control for floor heating systems

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

CITY PLUS. Wall-hung condensing boilers. ErP 24 HE 30 HE. Ready

Self-operated Temperature Regulators Series 43 Temperature Regulators Type 43-1 Type 43-2

Water Safety Shut-Off Valve HON 790. Product information. serving the gas industry worldwide

Automatic balancing valves ASV-PV (new generation) DN 32-50

According to the following European Regulations which come into force:

Installation, Operation and Maintenance Instructions for Electric Storage Calorifier

Mercury Mixing Kit (Code: ME1053)

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off

Installation, Operation and Maintenance Instructions Electric Flow Heater OM009

Multibox. Floor Heating Controller Flush individual room control for floor heating systems

OIL SEPARATORS APPLICATIONS

TS RD 7761 RD, 7761 RD

TECHNICAL. Series 18. Pump Packages

THERMOSTATIC MIXING VALVES FOR CONDENSATION PREVENTION

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier

Metering systems 0548EN April 2014

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

CRU-S Series Stainless Steel Condensate Recovery Unit

HERZ Differential Pressure Control Valve 4002

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

Lawnmowers, pedestrian controlled (combustion engine powered)

THERMODYNAMIC STEAM TRAP

HYDRONIC SPECIALTIES TACO MPT Tank(s) 05/30/2012. A. Multi-Purpose Tank buffer tank, air separator, and hydraulic decoupler

SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS

Conductivity Electrode LRG Original Installation Instructions English

IMMERSION HEATERS IMMERSION HEATERS FOR WATER 1½ BRASS NIPPLE, 3X400V: 2 BRASS NIPPLE, 3X400V:

caleffi hydronic valves page 1 of 12

HANDBOOK REGULATOR VALVES. Ed REGULATOR VALVES RP-ED 01/ ENG 1

Cooler Range. For use with AESSEAL Seal Support Systems.

Operating Instructions for Air-Flow Monitor. Model: LPS-P

Lowara ecocirc and ecocirc PREMIUM THE NEW HIGHLY EFFICIENT CIRCULATORS WITH THE PATENTED ANTI-BLOCK-TECHNOLOGY

541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P.

Diaphragm pump 4 - headed

Models Series Series

Boiler room components 0463EN October 2013

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

Model: 400E-5M. Bermad Hydraulically Controlled Anti-Columning Deluge Valve, with Easylock Manual Reset. Installation Operation Maintenance

Autotrol Performa FA Valve

CRU 200 and 500 Series Condensate Recovery Unit Installation and Maintenance Instructions

THERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES

Pressurisation units & expansion vessels

R586R. Distribution and Regulation units. Datasheet 0861EN 04/2019 R586RY103 R586RY102 R586RY101 R586RY104

Inverted bucket steam traps Type OKZ PN6/PN16

CALEFFI. Anti-condensation recirculation and distribution unit. 281 series 01224/14 GB. Replaces dp 01224/12 GB. Function

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield

Operation Manual. Diaphragm pumps 2-headed. Types MP 101 Zp, MP 201 Ep MPC 101 Zp, MPC 201 Ep

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

Documentation guide to get your plant on the positive list (Category A1/A2)

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function

Aquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Thermostatic three-way valve body. Thermostatic Radiator Valves without presetting, with automatic bypass control

NRG NRG NRG NRG

esfr dry pendent sprinkler Vk502 (k14.0)

MP 2401 E, MP 1801 Z, MP 1201 T

Multilux 4-Eclipse-Set

Forced draught gas burner

Thermostatic mixing valves with replaceable cartridge for centralized systems

Installation and maintenance instructions

Thermostatic mixing valves with interchangeable cartridges

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

Water Softener Installation Guide Effective for all Softeners from our Range

Betriebsanleitung Operating Instructions

ESFR PENDENT SPRINKLER VK500 (K14.0) TECHNICAL DATA

EUROSTER 11E CENTRAL HEATING/UTILITY HOT WATER SYSTEM PUMP CONTROLLER

DRYPACK. Protecting installations Energy optimisation. Operating principle. Description. Biogas dehumidification system. Improved profitability.

Installation, Operation and Maintenance Instructions Thermaflow E Plate Heat Exchanger Package OM013

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet

All our certificates could be downloaded from our web site:

TECHNICAL DATA NOTICE

GESTRA Steam Systems BK 15. Installation Instructions Steam Trap BK 15, DN 40-50

Instruction Manual, Rotary Spray Heads

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting

SPECIFICATIONS - NIKE

HERS Verified Single Dwelling Unit Hot Water System Distribution (Page 1 of 6)

The products covered by the Regulation can be classified as follows:

Installation & Operation Instructions Nr _EN_Manual

Garden blowers, vacuums and blower/vacuums (electric mains powered)

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

REIMERS ELECTRA STEAM, INC. INSTRUCTION MANUAL JG & JJ MODELS

RTE-5/5B & RTE-9/9B Refrigerated Bath Circulators. NESLAB Manual P/N Installation, Operation and Service Manual

Lawnmowers (pedestrian controlled electric mains-powered)

Transcription:

VST Series INAIL approved and calibrated safety valves Technical Data Sheet WattsIndustries.com

Description VST Series INAIL approved and calibrated safety valves automatically discharge enough liquid to ensure that the safety pressure setpoint is not exceeded. They protect the boiler and system, and require no energy except the pressurised fluid. The valves are designed and manufactured in compliance with R regulations - 2009 edition, applied technical specifications of Italian Ministerial Decree 1-12-1975. VST Diaphragm safety valve, fixed setting. CW617N brass body and cap. PN10. Overpressure: 10%. Blowdown: <20%. Temperature range: -10 120 C. F/F connections with oversized outlet. INAIL approved and calibrated. Compliant with PED 2014/68/EU with identification number CE1115. Type Part No. DN bar Weight (g) VST 0212122 1/2 x 3/4 2.25 420 VST 0212125 1/2 x 3/4 2.5 420 VST 0212127 1/2 x 3/4 2.7 420 VST 0212130 1/2 x 3/4 3 420 VST 0212135 1/2 x 3/4 3.5 420 VST 0212140 1/2 x 3/4 4 420 VST 0212145 1/2 x 3/4 4.5 420 VST 0212150 1/2 x 3/4 5 420 VST 0212154 1/2 x 3/4 5.4 420 VST 0212160 1/2 x 3/4 6 420 VST 0213122 3/4 x 1 2.25 780 VST 0213125 3/4 x 1 2.5 780 VST 0213127 3/4 x 1 2.7 780 VST 0213130 3/4 x 1 3 780 VST 0213135 3/4 x 1 3.5 780 VST 0213140 3/4 x 1 4 780 VST 0213145 3/4 x 1 4.5 780 VST 0213150 3/4 x 1 5 780 VST 0213154 3/4 x 1 5.4 780 VST 0213160 3/4 x 1 6 780 VST 0214122 1/2 x 1.1/4 2.25 1000 VST 0214125 1/2 x 1.1/4 2.5 1000 VST 0214127 1/2 x 1.1/4 2.7 1000 VST 0214130 1/2 x 1.1/4 3 1000 VST 0214135 1/2 x 1.1/4 3.5 1000 VST 0214140 1/2 x 1.1/4 4 1000 VST 0214145 1/2 x 1.1/4 4.5 1000 VST 0214150 1/2 x 1.1/4 5 1000 VST 0214154 1/2 x 1.1/4 5.4 1000 VST 0214160 1/2 x 1.1/4 6 1000 IS Exposed drain funnel for safety and thermal drain valves. Type Part No. DN Weight (g) IS 0235115 1/2 FF 270 IS 0235120 3/4 FF 400 IS 0235125 1 FF 600 IS 0235132 1.1/4 FF 1000 2

Technical features Nominal pressure PN10 Overpressure 10% Blowdown <20% Maximum operating temperature -10 C 120 C PED class IV Materials Body and cap Diaphragm and seals Manual discharge knob Setting spring Disc CW617N brass EPDM Impact-resistant technopolymer Galvanised C100 steel CW617N brass Approvals CE mark VST Series safety valves meet the requirements of the Pressure Equipment Directive 2014/68/UE (PED). The valves are classified in category IV, considered the highest risk category, given that they are safety devices and bear the CE mark followed by the number 1115, identifying the approval authority. INAIL VST Series safety valves are manufactured in accordance with the specifications and requirements of R regulations Chap. R.2.A (2009 Edition) and are supplied with INAIL approval and calibration certificates. The INAIL approval certificate is issued to the manufacturer after testing to ensure that it fully conforms with the operating characteristics required by the regulations. The document is valid for five years: all valves manufactured within this timeframe are INAIL approved indefinitely and can be used in systems without any time limits. The valves are tested individually and supplied with a unique calibration report, showing the serial number of the valve marked on the non-removable metal disc fixed in the knob. The calibration report must remain with the valve for its full service life. Application VST Series safety valves are generally used in closed-loop heating systems with nominal heat output of more than 35kW that use hot water at temperatures below 110 C. The safety valve protects the boiler and system tank from sudden, unexpected pressure surges. Valve opening can be triggered for various reasons: - fluid temperature rises above the maximum set value, resulting in uncompensated expansion; - expansion vessel undersized; - circuit overfilled. Therefore, the safety valve remains inoperative when the system is operating normally. 3

Operation The fluid in the system exerts pressure on the disc, which pushes against the spring until the pressure exceeds the declared setting. The disc then slowly starts to open, allowing the water flow to inflate the diaphragm. The valve opens and discharges into the air, relieving the system from dangerous pressure for the boiler and system components. The disc opens fully before the fluid pressure exceeds the pressure setpoint by 10% (overpressure). The valve closes before the pressure drops to 20% less than the setpoint pressure (blowdown). The outlet port has a wider diameter than the inlet port, to increase the discharge capacity of the valve. The characteristics of the materials prevent the valves from seizing as a result of ageing. 6 5 3 2 4 7 9 8 Key 1 - Valve body 2 - Disc 3 - Diaphragm 4 - Cap 5 - Setting nut 6 - Manual discharge knob 7 - Disc stem 8 - Setting spring 9 - Disc stem 1 4

Sizing The safety valve must be sized to ensure a discharge flow rate (Q), expressed in kg/h of vapour, of not less than: Q = P/0.58 where P = nominal heat output of boiler (kw) The setpoint pressure of the valve, plus the permitted overpressure, must not exceed the maximum operating pressure of the boiler. For boilers with individual heat output exceeding 580 kw (500,000 kcal/h), the discharge flow rate must be divided between at least two safety valves. Technical data and discharge flow rates with overpressure of 10% and blowdown of 20% Model Pressure in bar Ø of Section of Flow Discharge Nominal heat output orifice orifice coefficient flow rate of boiler setting max min discharge closure mm cm² K Kg/h Kcal/h kw 1/2 x 3/4 2.25 2.475 1.80 205.67 102,839 119.29 1/2 x 3/4 2.50 2.75 2.00 221.40 110,703 128.41 1/2 x 3/4 2.70 2.97 2.16 233.78 116,892 135.59 1/2 x 3/4 3.00 3.30 2.40 253.74 126,873 147.17 1/2 x 3/4 3.50 3.85 2.80 284.07 142,035 164.76 1/2 x 3/4 4.00 4.40 3.20 15 1.7671 0.71 318.07 159,039 184.48 1/2 x 3/4 4.50 4.95 3.60 344.78 172,393 199.97 1/2 x 3/4 5.00 5.50 4.00 376.39 188,196 218.30 1/2 x 3/4 5.40 5.94 4.32 399.70 199,850 139.04 1/2 x 3/4 6.00 6.60 4.80 442.81 221,407 256.83 3/4 x 1 2.25 2.475 1.80 412.01 206,006 238.96 3/4 x 1 2.50 2.75 2.00 443.52 221,760 257.24 3/4 x 1 2.70 2.97 2.16 468.31 234,156 271.62 3/4 x 1 3.00 3.30 2.40 508.30 254,151 294.81 3/4 x 1 3.50 3.85 2.80 20 3.1416 0.80 569.04 284,522 330.04 3/4 x 1 4.00 4.40 3.20 637.17 318,585 369.55 3/4 x 1 4.50 4.95 3.60 690.67 345,336 400.58 3/4 x 1 5.00 5.50 4.00 753.98 376,992 437.31 3/4 x 1 5.40 5.94 4.32 804.25 402,125 466.50 3/4 x 1 6.00 6.60 4.80 887.04 443,520 514.48 1/2 x 1.1/4 2.25 2.475 1.80 571.37 285,670 331.37 1/2 x 1.1/4 2.50 2.75 2.00 615.03 307,515 356.71 1/2 x 1.1/4 2.70 2.97 2.16 649.41 324,705 376.65 1/2 x 1.1/4 3.00 3.30 2.40 704.86 352,433 408.82 1/2 x 1.1/4 3.50 3.85 2.80 25 4.9087 0.71 789.09 394,548 457.67 1/2 x 1.1/4 4.00 4.40 3.20 883.56 441,783 512.46 1/2 x 1.1/4 4.50 4.95 3.60 957.75 478,879 555.49 1/2 x 1.1/4 5.00 5.50 4.00 1,045.55 522,776 606.42 1/2 x 1.1/4 5.40 5.94 4.32 1,120.24 560,117 649.79 1/2 x 1.1/4 6.00 6.60 4.80 1,230.06 615,031 713.43 5

Installation The safety valve must be installed as required by the technical specifications set down in R regulations - 2009 Edition, in accordance with the direction of flow shown by the arrow cast into the valve body. The valve must be connected to the highest part of the boiler or to the outlet pipe in the immediate vicinity of the boiler. In the latter case, the length of the pipe between the safety valve and the connection of the outlet pipe to the boiler must not exceed one metre. It must not be possible to shut off the pipe connecting the safety valve to the boiler, nor should the section of this pipe be at any point less than the safety valve inlet port section. The discharge pipe must be visible and routed to a siphon or receptacle (IS Series) so as not to cause injury to persons or damage to property, and to facilitate inspection in the event of opening. In order not to impair correct valve operation, avoid installing an elbow on the discharge pipe. Instead, use a curve with a radius of at least 3 times the diameter of the pipe. To ensure perfect efficiency, the safety valves require regular inspection. Over time, foreign matter may build up close to the disc; therefore the valve seat should be flushed periodically (e.g. at the start of the heating season). It can be flushed through manual discharge of the valve by turning the knob in the direction of the arrows. Almost all leaks (dripping, incomplete closing) are caused by debris lodged between the seat and disc; therefore, periodic inspection and flushing prevent these leaks and any ensuing problems. Fig.1 Direct installation of the funnel on the discharge pipe Fig.2 Common installation of the funnel where the discharge flow rate is high 6

Overall dimensions (mm) VST L IS H A DN DN h B DN L H h 1/2 x 3/4 37 119 24 3/4 x 1 48 165 29 1 x 1.1/4 54 190 34.5 DN A B 1/2 61 45 3/4 65 57 1 78 68 1.1/4 113 97 Specification text VST Series Diaphragm safety valve with fixed setting VST Series WATTS brand. CW617N brass body and cap. PN10. Overpressure: 10% Blowdown <20% Temperature range: -10 120 C. 1/2-1 F/F connections with oversized outlet. Suitable for water with glycol: up to 50%. INAIL approved and calibrated. Compliant with PED 1014/68/EU with identification number CE1115. IS Series Exposed brass drain funnel IS Series WATTS brand for safety and thermal drain valves. Diameters from 1/2 to 1 1/4 with FF connections. 7

The descriptions and photographs contained in this product specification sheet are supplied by way of information only and are not binding. Watts Industries reserves the right to carry out any technical and design improvements to its products without prior notice. Warranty: All sales and contracts for sale are expressly conditioned on the buyer s assent to Watts terms and conditions found on its website at www.wattsindustries.com. Watts hereby objects to any term, different from or additional to Watts terms, contained in any buyer communication in any form, unless agreed to in a writing signed by an officer of Watts. Watts Industries Italia S.r.l. Via Brenno, 21 20853 Biassono (MB) Italy Tel. +39 039 4986.1 Fax +39 039 4986.222 infowattsitalia@wattswater.com www.wattsindustries.com VST-TS-IT-W-UK-01-18-Rev.1 2017 Watts