Boiler room components 0463EN October 2013
|
|
- Alannah Hunter
- 6 years ago
- Views:
Transcription
1 40 90 Boiler room components 0463EN October 2013 Contact regulation thermostat Electrical connections Terminal 1: common input Terminal 2: opens the circuit with the increase in temperature Terminal 3: closes the circuit with the increase in temperature K373Y013 Description The K373Y013 is a regulation thermostat for use in a boiler room. The device is a contact one (to be assembled on the outside of the pipes). It is a regulating device that works automatically: when the water temperature set on the graduated knob (on the front, with a range of C) is reached, the heat flow from the generator is interrupted. This flow restarts automatically when the water temperature falls below the set value. Dimensions Warning. The device must be installed and wired up by specialised personnel only, scrupulously respecting the current safety standards and legal requirements. W 30 L 20 C Main characteristics Graduated knob for temperature regulation (in a range of C) Screws for temperature and differential regulation Output contacts (interruption or switchover) Contact capacity 16 (2,5) A / 250 V~ (cont. 1-2) - 2,5 A / 250 V~ (cont. 1-3) Assembly on pipes Fairlead M20 x 1,5 Protection degree IP30 Insulation class I Storage temperature C Technical data Differential 8 ±3 K Thermal gradient < 1 K/min Max. head temperature: 85 C Compliance Compliance with standards EN (and updates) and EN Compliance with directives 73/23/EEC (Low voltage), 89/68/EEC (Electromagnetic compatibility) and subsequent updates 93/68/EEC Compliance with PED directive 97/23/EC. EC mark 3/8 GAS L [mm] H [mm] W [mm] Product specifications K373Y013 Bimetallic contact regulation thermostat with temperature regulator. Contact assembly on heating system pipes. Graduated knob for temperature regulation, with a range of C. Screw for differential temperature regulation. Output contacts (interruption or switchover). CONTACT CAPACITY: contacts 1-2: 16 (2,5) A / 250 V. contacts 1-3: 2,5 A / 250 V. Fairlead M20x1,5. Protection degree IP30. Insulation class I. Storage temperature C. Differential 8 ±3 K. Thermal gradient < 1 K/min. Dimensions 45x112x55 mm (LxHxW). Max. head temperature 85 C. Dimensions 45x112x55 mm (LxHxW). Compliance with standards EN , EN Compliance with directives 73/23/EEC (Low voltage), 89/68/EEC (Electromagnetic compatibility). Compliance with PED directive 97/23/EC H 1
2 0463EN October 2013 Contact regulation thermostat Additional information For further information, visit the website or contact the technical service: ' * consulenza.prodotti@giacomini.com This information is intended as an example. Giacomini S.p.A. reserves the right to modify the contents - at any time and without prior warning - for technical or commercial reasons. The information in this technical sheet does not exempt the user from scrupulously observing the existing regulations and standards relating to good technical practices. Giacomini S.p.A. Via per Alzo, San Maurizio d Opaglio (NO) Italy 2
3 0464EN October 2013 Immersion regulation thermostat INAIL (ISPES.L) compliant Electric connections Terminal 1: opens the circuit with the increase in temperature Terminal 2: closes the circuit with the increase in temperature Terminal C: common input K373Y021 Description The K373Y021 is a regulation thermostat for use in a boiler room. It is INAILapproved. The device is an immersion one (with a sensitive bulb to be inserted in the housing). It is a regulating device that works automatically: when the water temperature set on the graduated knob (on the front, with a range of 0 90 C) is reached, the heat flow from the generator is interrupted. This flow restarts automatically when the water temperature falls below the set value. Dimensions Warning. The device must be installed and wired up by specialised personnel only, scrupulously respecting the current safety standards and legal requirements. L W1 W Note. Thermostat K373Y021 complies with the regulations of INAIL R collection - Technical application specifications of Title II of Ministerial Decree (Italy). H 1/2 NPT Main characteristics Knob for temperature regulation (in a range of 0 90 C) Output contacts (interruption or switchover) Contact capacity 10 (2,5) A / 250 V (cont.1) (2,5) A / 250 V (cont. 2) Bulb length 97 mm Housing (included) with 1/2 M connection; length 100 mm Fairlead M20 x 1,5 Protection degree IP40 Insulation class I Storage temperature C Technical data Tolerance ±3 K Differential 4 ±1 K Thermal gradient < 1 K/min Time constant < 1 Max. head temperature 80 C Max. bulb temperature 125 C Max. working pressure 10 bar Compliance Compliance with standards EN (and updates) and EN Compliance with directives 73/23/EEC (Low voltage), 89/68/EEC (Electromagnetic compatibility) (and subsequent updates) and 93/68/EEC Compliance with PED directive 97/23/EC EC mark L [mm] H [mm] W [mm] W1 [mm] Product specifications K373Y021 Immersion regulation thermostat. Assembly with sensitive bulb inserted in heating system pipes. Liquid expansion operating principle. TR regulation thermostat, type 1 action in accordance with INAIL "R" collection. Graduated knob for temperature regulation, with a range of 0 90 C. Output contacts (interruption or switchover). CONTACT CAPACITY: contact 1: 10 (2,5) A / 250 V. contact 2: 6 (2,5) A / 250 V. Bulb length 97 mm. Housing (included) with 1/2 M connection (length 100 mm). Fairlead M20x1,5. Protection degree IP40. Insulation class I. Storage temperature C. Tolerance ±3 K. Differential 4 ±1 K. Thermal gradient < 1 K/min. Time constant < 1 min. Dimensions 55x112x162 mm (LxHxW). Max. head temperature 80 C. Max. bulb temperature 125 C. Max. working pressure 10 bar. Compliance with standards EN , EN Compliance with directives 73/23/EEC (Low voltage), 89/68/EEC (Electromagnetic compatibility). Compliance with PED directive 97/23/EC.. 1
4 0464EN October 2013 Immersion regulation thermostat INAIL (ISPES.L) compliant Additional information For further information, visit the website or contact the technical service: ' * consulenza.prodotti@giacomini.com This information is intended as an example. Giacomini S.p.A. reserves the right to modify the contents - at any time and without prior warning - for technical or commercial reasons. The information in this technical sheet does not exempt the user from scrupulously observing the existing regulations and standards relating to good technical practices. Giacomini S.p.A. Via per Alzo, San Maurizio d Opaglio (NO) Italy 2
5 0465EN October 2013 Immersion safety and regulation bi-thermostat Compliance Compliance with standards EN (and updates) and EN Compliance with directives 73/23/EEC (Low voltage), 89/68/EEC (Electromagnetic compatibility) (and subsequent updates) and 93/68/EEC Compliance with PED directive 97/23/EC EC mark Electric connections K373Y022 Description The K373Y022 is a bi-thermostat for use in a boiler room. It is INAIL-compliant. The device is an immersion one (with a sensitive bulb to be inserted in the housing). The bi-thermostat combines regulation and safety (manual reset) functions in one single device. Note. Thermostat K373Y022 complies with the regulations of INAIL R collection - Technical application specifications of Title II of Ministerial Decree (Italy). Regulation function - The device has an automatic-type regulation function: when the water temperature set on the graduated knob (on the front, with a range of 0 90 C) is reached, the heat flow from the generator is interrupted. This flow restarts automatically when the water temperature falls below the set value. Safety function - The device has an automatic-type lockout function: when the calibration temperature of the limiter (pre-set in the factory at a value of 100 C) is reached, the heat flow from the generator is interrupted. This flow restarts when the water temperature falls below the set calibration value. The reset can only be made manually (using a tool, if necessary). LIMITER Terminal 2 = Opens the circuit with the increase in temperature Terminal C = Common input REGULATOR Terminal 1 = Opens the circuit with the increase in temperature Terminal 2 = Closes the circuit with the increase in temperature Terminal C = Common input Dimensions Warning. The device must be installed and wired up by specialised personnel only, scrupulously respecting the current safety standards and legal requirements. L W H Main characteristics Knob for temperature regulation (in a range of 0 90 C) Manual reset button Output contacts (interruption or switchover) Regulator contact capacity 10 (2,5) A / 250 V (cont. 1) (2,5) A / 250 V (cont. 2) Limiter contact capacity 10 (2,5) A / 250 V (cont. 2) Bulb length 97 mm Housing (included) with 1/2 M connection; length 100 mm 2 fairlead M20x1,5 Protection degree IP40 Insulation class I Storage temperature C Technical data Tolerance ±5 K (regulator), -6 K (limiter) Regulator differential 4 ±1 K Limiter differential 20 ±5 K Limiter factory calibration 100 C (+0 C / -6 C) Thermal gradient < 1 K/min Time constant < 1 min Max. head temperature 80 C Max. bulb temperature 125 C Max. working pressure 10 bar 1/2 NPT L [mm] H [mm] W [mm] Product specifications K373Y022 Regulation thermostat and safety thermostat. Assembly with sensitive bulb inserted in heating system pipes. Liquid expansion operating principle. TR regulation thermostat with type-1 action and STB safety thermostat with type- 2 in accordance with INAIL "R" collection. Graduated knob for temperature regulation, with a range of 0 90 C. Button for manual reset. Output contacts (interruption or switchover). REGULATOR CONTACT CAPACITY: contact 1: 10 (2,5) A / 250 V. contact 2: 6 (2,5) A / 250 V LIMITER CONTACT CAPACITY: contact 2: 10 (2,5) A / 250 V. Bulb length 97mm. Housing (included) with 1/2 M connection (length 100 mm). Two fairleads M20x1,5. Protection degree IP40. Insulation class I. Storage temperature C. Tolerance ±5 K (regulator), -6 K (limiter). Differential 4 ±1 K (regulator), 20 ±5 K (limiter). Limiter factory calibration 100 C (+0 C / - 6 C). Thermal gradient < 1 K/min. Time constant < 1 min. Dimensions 101x113x162 mm (LxHxW). Max. head temperature 80 C. Max. bulb temperature 125 C. Max. working pressure 10 bar. Compliance with standards EN , EN Compliance with directives 73/23/ EEC (Low voltage), 89/68/EEC (Electromagnetic compatibility). Compliance with PED directive 97/23/EC.. 1
6 0465EN October 2013 Immersion safety and regulation bi-thermostat Additional information For further information, visit the website or contact the technical service: ' * consulenza.prodotti@giacomini.com This information is intended as an example. Giacomini S.p.A. reserves the right to modify the contents - at any time and without prior warning - for technical or commercial reasons. The information in this technical sheet does not exempt the user from scrupulously observing the existing regulations and standards relating to good technical practices. Giacomini S.p.A. Via per Alzo, San Maurizio d Opaglio (NO) Italy 2
7 0466EN October 2013 Immersion safety thermostat Electric connections Terminal 2 = Opens the circuit with the increase in temperature Terminal C = Common input K373Y023 Warning. The device must be installed and wired up by specialised personnel only, scrupulously respecting the current safety standards and legal requirements. Description The K373Y023 is a safety thermostat (with STB-type functions) with manual reset, for use in a boiler room. It is INAIL-approved. The device is an immersion one (with a sensitive bulb to be inserted in the pipes). It works automatically: when the calibration temperature of the limiter (pre-set in the factory at a value of 100 C) is reached, the heat flow from the generator is interrupted. This flow restarts when the water temperature falls below the set calibration value. The reset can only be made manually (using a tool, if necessary). Dimensions L W Note. Thermostat K373Y023 complies with the regulations of INAIL R collection - Technical application specifications of Title II of Ministerial Decree (Italy). H 1/2 NPT Main characteristics Manual reset button Output contacts (interruption) Limiter contact capacity 10 (2,5) A / 250 V (cont. 2) Bulb length 97 mm Housing (included) with 1/2 M connection; length 100 mm Fairlead M20x1,5 Protection degree IP40 Insulation class I Storage temperature C Technical data Tolerance -6 K (limiter) Limiter factory calibration 100 C (+0 C / -6 C) Thermal gradient < 1 K/min Time constant < 1 min Max. head temperature 80 C Max. bulb temperature 125 C Max. pressure 10 bar L [mm] H [mm] W [mm] Product specifications K373Y023 Immersion safety thermostat. Assembly with sensitive bulb inserted in heating system pipes. Liquid expansion operating principle. STB safety thermostat, type 2 action in accordance with INAIL "R" collection. Button for manual reset. Output contacts (interruption or switchover). LIMITER CONTACT CAPACITY: contact 2: 10 (2,5) A / 250 V. Bulb length 97 mm. Housing (included) with 1/2 M connection (length 100 mm). Fairlead M20x1,5. Protection degree IP40. Insulation class I. Storage temperature C. Tolerance -6 K (limiter). Limiter factory calibration 100 C (+0 C / - 6 C). Thermal gradient < 1 K/min. Time constant < 1 min. Dimensions 55x110x162 mm (LxHxW). Max. head temperature 80 C. Max. bulb temperature 125 C. Max. working pressure 10 bar. Compliance with standards EN , EN Compliance with directives 73/23/EEC (Low voltage), 89/68/EEC (Electromagnetic compatibility). Compliance with PED directive 97/23/EC. INAIL (ISPESL) compliant. Compliance Compliance with standards EN (and updates) and EN Compliance with directives 73/23/EEC (Low voltage), 89/68/EEC (Electromagnetic compatibility) and subsequent updates 93/68/EEC Compliance with PED directive 97/23/EC EC mark 1
8 0466EN October 2013 Immersion safety thermostat Additional information For further information, visit the website or contact the technical service: ' * consulenza.prodotti@giacomini.com This information is intended as an example. Giacomini S.p.A. reserves the right to modify the contents - at any time and without prior warning - for technical or commercial reasons. The information in this technical sheet does not exempt the user from scrupulously observing the existing regulations and standards relating to good technical practices. Giacomini S.p.A. Via per Alzo, San Maurizio d Opaglio (NO) Italy 2
9 0546EN October 2013 Immersion safety thermostat Electric connections Terminal 2 = Opens the circuit with the increase in temperature Terminal C = Common input K373Y033 Warning. The device must be installed and wired up by specialised personnel only, scrupulously respecting the current safety standards and legal requirements. Description The K373Y033 is a safety thermostat (with STB-type functions) with manual reset, for use in a boiler room. It is INAIL-approved. The device is an immersion one (with a sensitive bulb to be inserted in the pipes). It works automatically: when the calibration temperature of the limiter (pre-set in the factory at a value of 110 C) is reached, the heat flow from the generator is interrupted. This flow restarts when the water temperature falls below the set calibration value. The reset can only be made manually (using a tool, if necessary). Dimensions ,5 Note. Thermostat K373Y033 complies with the regulations of INAIL R collection - Technical application specifications of Title II of Ministerial Decree (Italy) /2 NPT Main characteristics Manual reset button Output contacts (interruption) Limiter contact capacity 10 (2,5) A / 250 V (cont. 2) Bulb length 97 mm Housing (included) with 1/2 M connection; length 100 mm Fairlead M20x1,5 Protection degree IP40 Insulation class I Storage temperature C Technical data Tolerance -6 K (limiter) Limiter factory calibration 110 C (+0 C / -6 C) Thermal gradient < 1 K/min Time constant < 1 min Max. head temperature 80 C Max. bulb temperature 125 C Max. pressure 10 bar L [mm] H [mm] W [mm] Product specifications K373Y033 Immersion safety thermostat. Assembly with sensitive bulb inserted in heating system pipes. Liquid expansion operating principle. STB safety thermostat, type 2 action in accordance with INAIL "R" collection. Button for manual reset. Output contacts (interruption or switchover). LIMITER CONTACT CAPACITY: contact 2: 10 (2,5) A / 250 V. Bulb length 97 mm. Housing (included) with 1/2 M connection (length 100 mm). Fairlead M20x1,5. Protection degree IP40. Insulation class I. Storage temperature C. Tolerance -6 K (limiter). Limiter factory calibration 110 C (+0 C / - 6 C). Thermal gradient < 1 K/min. Time constant < 1 min. Dimensions 55x110x162 mm (LxHxW). Max. head temperature 80 C. Max. bulb temperature 125 C. Max. working pressure 10 bar. Compliance with standards EN , EN Compliance with directives 73/23/EEC (Low voltage), 89/68/EEC (Electromagnetic compatibility). Compliance with PED directive 97/23/EC. INAIL (ISPESL) compliant. Compliance Compliance with standards EN (and updates) and EN Compliance with directives 73/23/EEC (Low voltage), 89/68/EEC (Electromagnetic compatibility) and subsequent updates 93/68/EEC Compliance with PED directive 97/23/EC EC mark 1
10 0546EN October 2013 Immersion safety thermostat Additional information For further information, visit the website or contact the technical service: ' * consulenza.prodotti@giacomini.com This information is intended as an example. Giacomini S.p.A. reserves the right to modify the contents - at any time and without prior warning - for technical or commercial reasons. The information in this technical sheet does not exempt the user from scrupulously observing the existing regulations and standards relating to good technical practices. Giacomini S.p.A. Via per Alzo, San Maurizio d Opaglio (NO) Italy 2
R557R EN January 2012
R7R- 077EN January 0 07U 00 00 00 WITH HIGH TEMPERATURE MANIFOLDS Example: R7RY0 + RAY00 R7R- WITH THERMAL ENERGY METERING Description R7R- group is used for the regulation of the fixed point heating for
More informationPRE-ASSEMBLED MANIFOLD FOR HEATING SYSTEMS WITH THERMOSTATIC MIXING
PRE-ASSEMBLED MANIFOLD FOR HEATING SYSTEMS WITH THERMOSTATIC MIXING R557 SUMMARY 1. APPLICATION 1. OPERATING 2. COMPONENTS 3. OVERALL DIMENSIONS 4. APPLICATION EXAMPLE 6. POSITIONING OF THE HEAD WITH THERMOSTATIC
More informationMetering systems 0548EN April 2014
08EN April 0 0U8 GEY - Y - Y (GE- series) 900 000/ 00 00A/ 800 00L/ Versions and product codes Product code Type Heat exchanger nominal power GEY, - GEY and production GEY and production Table - Product
More informationThermostatic head with wax sensor
Combined with valves covered by EN215 01 november 2004 ı Technical communication n da Use In modern society research concerning comfort in the home becomes a factor of prime importance. In order to obtain
More informationAir treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings
0932EN October 2017 CHARACTERISTIC DATA Air flow rate [m 3 /h] 200 Pressure available (factory configuration) [Pa] 15 Moisture removed (26 C - 65% R.H. - inlet water 15 C) [l/24h] 24,7 Max. absorbed electric
More informationControl Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW
1 212 Double thermostat Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW RAZ-TW... 2-position control thermostat and thermal reset limit thermostat with singlepole
More informationMetering systems 0670EN March 2017 Volumetric thermal energy meters for use in a boiler room GE552-1 series
Threaded version Flanged version GE552-1 Description The GE552-1 volumetric meters are used in the boiler room, to measure the heating and conditioning energy. They are strongly recommended for energy
More informationMetering systems 0371EN July 2016 User satellites, GE556 series Versions GE556Y301, GE556Y302
071N July 01 Versions GY01, GY0 igure 1 GY01 GY0 Description The G user satellites are the ideal metering solution in condominium systems with the centralised production of heating water and zone-based
More informationSPDT contacts: C/NO/NC. Contact Rating 16(4)A 250Vca. 7A1-1R306-00A A1-6R306-00A A A A A 10 90
ENCASED THERMOSTATS Derived from the range of capillary control thermostats and limiters with liquid filled sensing element, they are the accurate, reliable and easily set-up devices for the regulation
More informationPower X High Power Condensing Wall-Hung Boilers
Power X High Power Condensing Wall-Hung Boilers NEW Residential Heating/Light Commercial compliant POWER X / High Power Condensing Condensing Wall-Hung Wall-Hung Boilers Boilers Power X: the new high power
More informationRadiators: indirect energy metering and components
ENERGY MANAGEMENT E001EN PRODUCTS Radiators: indirect energy metering and components Heat cost allocators for energy consumption metering, thermostatic heads, valves and lockshield valves, air vent valves,
More informationPower X High Power Condensing Wall-Hung Boilers
Power X High Power Condensing Wall-Hung Boilers NEW Residential Heating/Light Commercial compliant POWER X / High Power Condensing Condensing Wall-Hung Wall-Hung Boilers Boilers Power X: the new high power
More informationIMMERSION HEATERS IMMERSION HEATERS FOR WATER 1½ BRASS NIPPLE, 3X400V: 2 BRASS NIPPLE, 3X400V:
1½ or 2 RG IMMERSION HEATERS PAGE 1/5 Immersion heaters* are used to heat a variety of mediums, e.g. water, glycol, oil, and other liquids. It is important that the immersion heater is fitted to the side
More informationSUMMARY DOMESTIC ENVIRONMENTAL REGULATION
PRODUCT RANGE 16 Our philosophy IMIT CONTROL SYSTEM has decided to accept the challenge: new products, top quality, immediateness of working process, with a careful and specific look at renewable energies.
More informationCALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB
Set point thermostatic regulating unit 8 series FM 65 00 CALEFFI 090/8 GB replaces dp 090/5 GB Function The thermostatic regulating unit is made to be used in radiant panel systems, in combination with
More informationType 5347 (TR/STL), Type 5348 (TR/ST) and Type 5349 (STM/STL) Double Thermostats
Thermostats Type 343 Safety Temperature Monitor (STM) Type 344 Temperature Regulator (TR) Type 34 Safety Temperature Limiter (STL) Type 347 (TR/STL), Type 348 (TR/ST) and Type 349 (STM/STL) Double Thermostats
More informationPRODUCT RANGE IMIT CONTROL SYSTEM
PRODUCT RANGE 15 10 IMIT CONTROL SYSTEM IMIT: leader in thermoregulation for over a hundred years. History Since 1917, at IMIT we have always discussed solutions. We began with electromechanics, becoming
More informationThermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597
1 202 Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597 RAK-TW.1..H RAK-TW.1..H.. Use Function Changeover switch (S.P.D.T.) 2-position thermal reset limit thermostat with single-pole
More informationSOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS
SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS INDEX Ed. 20150422 GENERAL INFORMATION... 2 Before installing... 2 Materials and PED (97/23/CE) Standards... 3 SKID-TYPE DISTRICT HEATING
More informationV. DIFFERENTIAL THERMOSTAT
DTC 200/2G DTC 200/2G is a differential thermostat, designed for heating DHWT (domestic hot water tank) from one heating source (solar collectors, boilers, heat pumps) with possibility to control the burner
More informationVST Series. INAIL approved and calibrated safety valves. Technical Data Sheet. WattsIndustries.com
VST Series INAIL approved and calibrated safety valves Technical Data Sheet WattsIndustries.com Description VST Series INAIL approved and calibrated safety valves automatically discharge enough liquid
More informationHEATING AND COOLING UNDERFLOOR SYSTEM
HEATING AND COOLING UNDERFLOOR SYSTEM HEATING IN WINTER COOLING IN SUMMER WITH A SINGLE SYSTEM Radiant panels provide to human body greater comfort than traditional heating systems. The sweet wellness
More informationSemi flush-mount room thermostat
3 078 Semi flush-mount room thermostat for CAV / VAV heating and cooling systems for AHU systems for universal heating and cooling systems RDU340 Modulating PI control Control depending on the room or
More informationGENERAL CATALOGUE MICROMETRIC, THERMOSTATIC VALVES THERMOSTATIC VALVES MANUAL VALVES LOCKSHIELDS ACCESSORIES AND SPARE PARTS
GENERAL CATALOGUE MICROMETRIC, TERMOSTATIC VALVES TERMOSTATIC VALVES MANUAL VALVES LOCKSIELDS ACCESSORIES AND SPARE PARTS SUMMARY 1. USE 2. MICROMETRIC TERMOSTATIC VALVES 3. TECNICAL DATA 3. MATERIALS
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL
CONTROL PANEL RIELLOtech PRIME INSTALLATION, OPERATION AND MAINTENANCE MANUAL CONFORMITY RIELLOtech control panels conform to: Low Voltage Directive 06/95/EC (ex-directive 73/23/EEC) Electromagnetic Compatibility
More informationFrost Protection Thermostat
1 203 Frost Protection Thermostat Electromechanical thermal reset limit thermostat RAK-TW.5..H RAK-TW.5..H.. Use Monitoring of frost protection temperature, with single-pole changeover microswitch Switching
More informationTubular Industrial Process
Alternate NEMA 1 Housing Type 3N (for no thermostat) for 1", 1-1/4", 2" and 2-1/2" Screw Plug Heaters Screw Plug Immersion Heaters TYPE 4N (for no thermostat) for 1", 1-1/4", 2" and 2-1/2" Screw Plug Heaters
More informationAquastats. Aquatrol Indoor/Outdoor Control. Automatic Changeover Switch 16/05/08
16/05/08 Aquatrol Indoor/Outdoor Control B3 Adjustable settings for boiler maximum temperature, boiler minimum temperature and outdoor low (design) temperature Selectable Warm Weather Shut Down (WWSD)
More informationThe Right Temperature, Always THS Series Modular Thermostats
The Right Temperature, Always THS Series Modular Thermostats Optimizing Control From ABB, a solution for precise and effective heat regulation The THS series modular thermostats manufactured by ABB meet
More information610 AC3 CONTROL KNOB (OFF, PILOT, ON) TEMPERATURE SELECTION KNOB ON-OFF REGULATING THERMOSTAT THERMOELECTRIC SAFETY DEVICE.
SIT Group 610 AC3 MULTIFUNCTIONAL GAS CONTROL CONTROL KNOB (OFF, PILOT, ON) TEMPERATURE SELECTION KNOB ON-OFF REGULATING THERMOSTAT THERMOELECTRIC SAFETY DEVICE PIN 0085AO0252 THERMOSTATIC MULTIFUNCTIONAL
More informationA series of technical features make this gas detector extremely versatile, reliable, accurate, and safe.
Belonging to Made in Italy GS911K Gas Detector GS911K Using the catalytic sensor inside it, the GS911K detector detects the presence of explosive gas such as: Methane, LPG, with trip sensitivity calibrated
More information5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341
NA31 www.caleffi.com Low Lead High Flow Thermostatic Mixing Valves Copyright 1 Caleffi Installation, commissioning and service instructions Function 531 Series ASSE 17 model 531 series high flow thermostatic
More informationEUROBOX SERIES TYPES CM...N SM...N MM...N
EUROBOX SERIES TYPES CM...N SM...N MM...N AUTOMATIC CONTROL SYSTEMS FOR GAS BURNERS AND GAS BURNING APPLIANCES WITH OR WITHOUT FAN (MANUAL RESET) DESCRIPTION This series of electronic systems is suitable
More informationPortable Gas Detector RP110. User Guide. Explosive gas detection SEMICONDUCTOR sensor technology Intrinsically safe. Conformity EMC EN50270.
Belonging Portable Gas Detector RP110 The RP110 portable gas detector is an electronic instrument manufactured by BEINAT S.r.l. to help technicians during testing or to search for and locate leaks in gas
More informationEUROFLAT SERIES TYPES C... S... M...
EUROFLAT SERIES TYPES C... S... M... AUTOMATIC CONTROL SYSTEMS FOR GAS BURNERS AND GAS BURNING APPLIANCES WITH OR WITHOUT FAN APPLICATION The electronic systems of this range are suitable to control gas
More informationTEMPERATURE CONTROLLERS
Instruction Manual: H1 T-12 Thermostat PILOT GUARD INTRODUCTION: SCOPE: This instruction manual includes installation, operation, and parts information for the Kimray Thermostat and Pilot Guard. Refer
More informationSystems for central heating
www.far.eu Highlight Systems and Components for central heating Components for renewable energy systems Pressfar Fittings Presetting valves and thermostatic head Balancing devices Zone valves Metering
More informationCALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA
Thermostatic mixing valves with replaceable cartridge for centralized systems 3, 3 series CCREDITED ISO 9 FM ISO 9 No. 3 /3 N Replaces / N Function The thermostatic mixing valve is used in systems producing
More informationSUPPLY TO CENTRAL HEATING SYSTEM SUPPLY TO DHW TANK RETURN FROM CENTRAL HEATING SYSTEM RETURN FROM DHW TANK
This booklet will assist you in piping, wiring and setting the controls of the Riva Advance SV boiler to control an indirect fired hot water tank. All pipe tails for the connection to the tank are supplied
More informationRoom thermostat with Auto Timer, Option External Input
s 1 422 Room thermostat with Auto imer, Option External Input for heating systems RDE100.. Room temperature control 2-position control with On/Off output for heating Comfort, Economy, Auto timer and Protection
More informationRL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw
The RL/1 burners series covers a firing range from 107 to 398 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Optimisation
More informationCAST IRON ATMOSPHERIC BOILERS
CST IRON TMOSPHERIC OILERS 006 gas-fired, central heating only, electronic ignition High efficiency boilers designed heating large domestic application. Ideal for installation in any boiler room. Cast-iron
More informationDEVIATING VALVES ART K063
FUNCTION The flow diverter valve Art.307 makes it possible to supply a branch circuit. Prepared to receive our electro-thermal controls Art. 978, 979, 980 or our thermostatic heads with remote sensor Art.
More informationCONTROL UNIT FOR UNDERFLOOR HEATING SYSTEMS
ST.04.04.00 ONTROL UNIT FOR UNERFLOOR HETING SYSTEMS Low temperature control unit Low+high temperature control unit 1. ONTROL UNIT PPLITION The FR control unit is suitable for systems combining both high
More informationAdjustable three-way thermostatic mixing valve... connections ½", ¾", 1" NPT male union and sweat union and ¾" press
MixCal djustable three-way thermostatic mixing valve series CCRIT ISO 9 FM ISO 9 No. CLFFI / N Replaces / N Function The Caleffi MixCal series three-way thermostatic mixing valve is used in systems producing
More informationCALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function
Thermostatic regulating unit for heating systems 66 series ACCREDITED ISO 9 FM 6 8/7 GB replaces dp 8/ GB Function The thermostatic regulating unit performs the function of keeping the flow temperature
More informationPTG series valves 0490EN June 2018 Valves with thermostatic option for radiators, with presetting
PT series valves 090E une 08 R0PT R0PT RPT RPT R0PT RPT escription The PT valves with thermostatic option and presetting are used to slice the delivery water flow rate in a radiator. hen the special worksite
More informationFor the user / for the installer. Instructions for Use and Installation. time SWITCH hour time clock
For the user / for the installer Instructions for Use and Installation time SWITCH 130 24 hour time clock GB GB Contents GB 24 hour time clock Operating instructions page 4-9 Installation instructions
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL
INSTALLATION, OPERATION AND MAINTENANCE MANUAL idealtech PRIME CONTROL PANEL For Users Guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured
More informationTemperature Sensor TRG Original Installation Instructions English
Temperature Sensor TRG 5-6.. EN English Original Installation Instructions 818597-05 1 Contents Important notes Page Usage for the intended purpose...4 Function...4 Safety note...4 Directives and standards
More informationThermostatic mixing valves with replaceable cartridge for centralized systems
Thermostatic mixing valves with replaceable cartridge for centralized systems series REGISTERED BS EN ISO 9: Cert. n FM UNI EN ISO 9: Cert. n / N Replaces /9 N Function The thermostatic mixing valve is
More informationSeries A36 3- and 4 Stage Thermostats for Refrigeration, Cooling, Heating, Ventilation and Air-conditioning. Feature and Benefits
PSC966 European Refrigeration Controls Catalogue Catalog Section Product Bulletin A6 Series A6 - and 4 Stage Thermostats for Refrigeration, Cooling, Heating, Ventilation and Air-conditioning Introduction
More informationTHERMASREG TR 040 THERMASREG TR 060
THERMASREG TR 040 THERMASREG Temperature controllers, one-step, Mechanical temperature controllers wet room temperature controllers THERMASREG TR 040 with switching output and stainless steel capillary
More informationUSERS MANUAL FOR GAS BOILERS
USERS MANUAL FOR GAS BOILERS PLEASE READ THE MANUAL CAREFULLY: IT CONTAINS IMPORTANT INFORMATION REGARDING SAFETY, INSTALLATION, USE AND MAINTENANCE OF THE APPLIANCE MODELS: NOVADENS 24 NOVADENS 24C NOVADENS
More informationLowara ecocirc and ecocirc PREMIUM THE NEW HIGHLY EFFICIENT CIRCULATORS WITH THE PATENTED ANTI-BLOCK-TECHNOLOGY
NE W Lowara ecocirc and ecocirc PREMIUM THE NEW HIGHLY EFFICIENT CIRCULATORS WITH THE PATENTED ANTI-BLOCK-TECHNOLOGY Ecocirc_Premium_uk.indd 1 28/10/13 12.26 How can efficiency even w The simple spherical
More information5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341.
NA3. www.caleffi.com Low Lead High Flow Thermostatic Mixing Valves Copyright 5 Caleffi Installation, commissioning and service instructions Function 53 Series ASSE 7 model 53 series high fl ow thermostatic
More informationCONTROL PANEL. RIELLOtech PRIME ACS INSTALLATION, OPERATION AND MAINTENANCE MANUAL
CONTROL PANEL RIELLOtech PRIME ACS INSTALLATION, OPERATION AND MAINTENANCE MANUAL Lecco, 18th January 12 The company Riello SpA Heating Products Direction Via Risorgimento 13 23900 Lecco ITALY hereby declares
More informationINSTALLATION AND MAINTENANCE INSTRUCTIONS INSTALLATION AND SERVICING MANUAL
ENGLISH BCM BOILER CONTROL MANAGER INSTALLATION AND MAINTENANCE INSTRUCTIONS INSTALLATION AND SERVICING MANUAL 1 General Information BCM is able to operate: - as a signal boiler controller. This enables
More informationCHCO Double Gas Detector
Belonging to Made in Italy HO Double Gas Detector HO The HO Detector has been designed and built according to European regulations to detect the presence of toxic and explosive gas. A microprocessor is
More informationOpen Vented Condensing Boilers
Dimplex 18 OV Dimplex 32 OV Open Vented Condensing Boilers User s Operating Instructions These instructions should be left with the user Dimplex Boilers 2008 CONTENTS SECTION DESCRIPTION PAGE 1.0 Using
More information521 Series. MixCal adjustable three-way thermostatic mixing valve. Installation, commissioning and service instructions
MixCal adjustable three-way thermostatic mixing valve 37. www.caleffi.com Copyright 15 Caleffi 51 Series Installation, commissioning and service instructions Function The Caleffi MixCal three-way thermostatic
More informationACCREDITED. Product range Code A2L Pre-assembled set point temperature regulating unit with manifolds and box, with UPM3 Auto L pump
Set point temperature regulating unit series ACCREDITED ISO 9 FM / GB replaces dp / GB Function The temperature regulating unit is made to be used in radiant panel systems, in combination with distribution
More informationESi CONTROLS BROCHURE LANDSCAPE V5.indd 1 14/08/ :31
ESi CONTROLS BROCHURE LANDSCAPE V5.indd 1 14/08/2014 18:31 The ESi family of programmers are a feature packed range, offering flexibility and reliability for use in any domestic heating and hot water installations.
More informationTRG 5-53 TRG 5-54 TRG 5-55 TRG 5-57
GESTRA GESTRA Steam Systems TRG 5-53 TRG 5-54 TRG 5-55 TRG 5-57 EN English Installation & Operating Instructions 810428-05 Temperature Sensor TRG 5-53, TRG 5-54, TRG 5-55, TRG 5-57 1 Contents Application
More informationVS LD series vertical steam sterilizers
VS LD series vertical steam sterilizers Steelco vertical Steam Sterilizers VS LD series are designed to answer the typical sterilization needs of a laboratory: glassware, stainless steel instruments, culture
More informationSMART Electronic control for towel radiators
SMART is an electronic thermostat for the automatic control of electric towel radiators. By means of an internal sensor it is capable of keeping the temperature of the towel radiator to a desired value.
More informationProgrammable Towel Radiator Manual
Programmable Towel Radiator Manual Contents Description Page 3 Location Page 4 Mountings Page 5 Starting Up Page 6+7 Return To The Initial Settings Page 8 Time Setting Page 9 Setting The Temperature (Set-Points)
More informationCOMBY 4000 & 9000 STEAM CLEANER OPERATOR MANUAL
COMBY 4000 & 9000 STEAM CLEANER OPERATOR MANUAL Clemas & Co. Unit 5 Ashchurch Business Centre, Alexandra Way, Tewkesbury, Gloucestershire, GL20 8NB. Tel: 01684 850777 Fax: 01684 850707 Email: info@clemas.co.uk
More informationR586R. Distribution and Regulation units. Datasheet 0861EN 04/2019 R586RY103 R586RY102 R586RY101 R586RY104
R8R Distribution and Regulation units Datasheet 08EN 0/09 R8RY0 R8RY0 R8RY0 R8RY0 Unit with insulation and actuator (optional) R8RY R8RY R8RY R8RY R8R distribution units control heating and cooling for
More informationSelf-learning Room Temperature Controller
2 226 Self-learning Room emperature Controller with analogue 24-hour or weekly time switch and possibility of remote control RAV12 Mains powered room temperature controller featuring straightforward operation.
More informationFan heater SWT Ceiling mounted fan heater with water heat
Fan heater heat 3 models Fan heater Ceiling mounted fan heater with water heat Application The fan heater is used for heating entrances, stores, industrial premises, workshops, sports halls, garages and
More informationETO 2 - Controller for ice and snow melting
ETO 2 - Controller for ice and snow melting Advantages Simple adjustment knob with two functions Illuminated display where you can easily see the temperature status and other values Controls both pumps
More informationSelf-learning Room Temperature Controller
Self-learning Room emperature Controller with two 24-hour operating modes Mains-independent room temperature controller featuring straightforward operation and an easy-to-read display. Self-learning two-position
More informationSelf-learning Room Temperature Controller
2 224 Self-learning Room emperature Controller with analogue 24-hour or weekly time switch RAV11 Mains-independent room temperature controller featuring straightforward operation. Self-learning two-position
More informationVIESMANN. VITOMAX 200-LW Low pressure hot water boiler for permissible flow temperatures up to 120 C Rated heating output 8.0 to 20.0 MW.
VIESMANN VITOMAX 200-LW Low pressure hot water boiler for permissible flow temperatures up to 120 C Rated heating output 8.0 to 20.0 MW Datasheet Part no. and prices on request VITOMAX 200-LW Type M64A
More informationDe Longhi Appliances via Seitz, Treviso Italia /11.13
Proudly distributed by De Longhi ustralia Pty Limited P.O. BOX 4540 CSUL MLL NSW 2170 Customer Service Ph: 1800 126 659 Fax: 1800 706932 www.delonghi.com.au e-mail: delonghi@delonghi.com.au De Longhi New
More informationINSTALLATION, OPERATION AND MAINTENANCE
INLINE HEATER INSTALLATION, OPERATION AND MAINTENANCE MODELS: ILS SERIES 1.5kW 120V SINGLE PHASE BEFORE YOU BEGIN CHECK ALL ELECTRICAL CONNECTIONS TO ALL COMPONENTS WITHIN THE HEATER FOR TIGHTNESS. CONNECTIONS
More informationThe guarantee on this appliance is valid for 12 months from the first day of installation.
Users Manual Dear Customer, Thank you for choosing an ARISTON boiler. We guarantee that your boiler is a reliable and technically sound product. This Users Manual provides detailed instructions and recommendations
More informationThermometers with capillary tube. Bimetal thermometers. Industrial thermometers. Resistance thermometers
Thermometers with capillary tube Bimetal thermometers Industrial thermometers Resistance thermometers CHAPTER Temperature measuring instruments and controllers OVERVIEW Mechanical temperature measuring
More informationFlame Safeguards LFE10. Building Technologies HVAC Products
7 71 Flame Safeguards LAE LFE Flame safeguards for burners with intermittent operation The LAE is used for the supervision and indication of oil flames The LFE is used for the supervision and indication
More informationir-range 8G /03.15 Changes reserved.
U s e r m a n u a l ic-range is-range ir-range 8G.52.80.00/03.15 Changes reserved. Contents 1. Introduction...3 2. Safety...5 3. Boiler description...6 4. Display and functions...7 4.1 DHW and Heating
More informationThermostatic mixing valves with interchangeable cartridges
www.caleffi.com R37. Thermostatic mixing valves with interchangeable cartridges Installation, commissioning and servicing instructions 3 Series Function The thermostatic mixing valve is used in systems
More informationIndustrial infrared heater IR
Industrial infrared heater For premises with large volumes and high ceilings 3 models 3 3000 6000 W Application is suitabe for total or supplementary heating of premises with large volume and high ceilings.
More information6600 SERIES 8-Pin DIP, Subminiature Bimetal Disc Thermostat
6600 SERIES 8-Pin DIP, Subminiature Bimetal Disc Thermostat Introduction The Airpax 6600 series is a RoHS compliant, positive snap action, single pole / single throw, sub-miniature bimetallic thermostat
More informationHCF100 Refrigerant FREON R410A, R134a, R407C, R404A
Belonging to Conventional Gas Probe HCF100 Refrigerant FREON R410A, R134a, R407C, R404A The new HCF100 is born from the elegance and prestige that has always distinguished BEINAT S.r.l. and from the home
More informationGALATEA DOMUS. Dal 1901 COD
GALATEA DOMUS COD. 9942031.07 REV.00 TABLE 1 Mod. S 1 5163184CM RH CUP-HEATER PIPE 2 5074616LW CUPS-HEATER GRID 3 7819912 SCREW M4X6 4 7474217 ADHESIVE FEET 12,7 H5,8 5 5961602.01 CUPS-HEATER 6 7816002
More informationDEHUMIDIFIERS FOR SWIMMING POOL. International. ET INTERNATIONAL S.r.l. Via Circonvallazione Est, 32/R Castelfranco Veneto - TREVISO - ITALY
International DEHUMIDIFIERS FOR SWIMMING POOL ET INTERNATIONAL S.r.l. Via Circonvallazione Est, 32/R - 31033 Castelfranco Veneto - TREVISO - ITALY TELEFONO: +39 0423 491100 E-MAIL: info@etinternationalsrl.com
More informationGAISER 4000 STEAM CLEANER OPERATOR MANUAL
GAISER 4000 STEAM CLEANER OPERATOR MANUAL Clemas & Co. Unit 5 Ashchurch Business Centre, Alexandra Way, Tewkesbury, Gloucestershire, GL20 8NB. Tel: 01684 850777 Fax: 01684 850707 Email: info@clemas.co.uk
More informationRoom panel. for ecomax800 R or T regulators. OPERATION AND MAINTENANCE MANUAL ISSUE: 1.3 APPLICABLE TO SOFTWARE: v , v , v08.21.
Room panel ecoster 200 for ecomax800 R or T regulators OPERATION AND MAINTENANCE MANUAL ISSUE: 1.3 APPLICABLE TO SOFTWARE: v08.21.014, v08.21.015, v08.21.016 2010-08-31 TABLE OF CONTENTS 1. SAFETY...
More informationRF ELECTRONIC PROGRAMMABLE ROOM THERMOSTAT, 7 DAY
USER GUIDE RF ELECTRONIC PROGRAMMABLE ROOM THERMOSTAT, 7 DAY When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification
More informationApplication guide RDG160 Remote control
Application guide RDG160 Remote control Providing indoor climate comfort RDG160-AGU-0509-E RDG100/RDG110 RDG140/RDG160 RDG100 Wall-mounted Room hermostats with Display for fan coil units application for
More informationUser Manual RBS 24. for model CE series ENERGY. Wall mounted instantaneous combi boiler room sealed chamber
User Manual for model RBS 24 series ENERGY Wall mounted instantaneous combi boiler room sealed chamber CE 0694 RBS 24 - SERIE ENERGY - RAD - ING - MAN.UT - 1407.1 - DIGITECH TR - MIAH6 - E04 Technical
More informationElectronic Dual Cylinder Thermostat Installation Instructions
ESCTDEB Electronic Dual Cylinder Thermostat Installation Instructions Thank you for choosing ESi Controls. All our products are tested in the UK so we are confident this product will reach you in perfect
More informationProduct range Code HE1 Connection and energy management compact unit without anti-condensation valve
Connection and energy management compact unit 2850 series ACCREDITED CALEFFI 01259/14 GB ISO 9001 FM 21654 ISO 9001 No. 0003 Function The connection and energy management compact unit enables combining
More informationElztrip EZ100. Elztrip EZ100. Single panel radiant heater for offices, shops etc. Product specifications
Single panel radiant heater for offices, shops etc. 3 models 3 600 1500 W Application 00 is intended for total and supplementary heating as well as protection against cold draughts from windows in environments
More informationAt Coster we manufacture a comprehensive range of pre confi gured modular controllers which are both easy to install and simple to programme by use
At Coster we manufacture a comprehensive range of pre confi gured modular controllers which are both easy to install and simple to programme by use of 4 operating keys and an alphanumeric display. When
More informationSeries A28 Two stage Thermostats. Feature and Benefits
PSC9626 European Refrigeration Controls Catalogue Catalog Section 1 Product Bulletin A28 Series A28 Two stage Thermostats I ntroduction These thermostats are designed for various types of heating, cooling,
More informationMercury Mixing Kit (Code: ME1053)
Mercury Mixing Kit (Code: ME1053) The installation and commissioning of the UFH mixing kit system must be exclusively performed by qualified personnel in accordance with the national guidelines and/or
More informationIndustrial infrared heater IR For premises with large volumes and high ceilings
Electrically heated 3000 6000 W 3 models Industrial infrared heater For premises with large volumes and high ceilings Application is suitabe for total or supplementary heating of premises with large volume
More informationSemi flush-mount room thermostats
s 1 440 RDD310/EH RDE410/EH Semi flush-mount room thermostats for control of electric floor heating systems and for hydronic zone control systems RDD310/EH RDE410/EH Key features of both types of thermostats:
More information