R586R. Distribution and Regulation units. Datasheet 0861EN 04/2019 R586RY103 R586RY102 R586RY101 R586RY104

Size: px
Start display at page:

Download "R586R. Distribution and Regulation units. Datasheet 0861EN 04/2019 R586RY103 R586RY102 R586RY101 R586RY104"

Transcription

1 R8R Distribution and Regulation units Datasheet 08EN 0/09 R8RY0 R8RY0 R8RY0 R8RY0 Unit with insulation and actuator (optional) R8RY R8RY R8RY R8RY R8R distribution units control heating and cooling for one zone of the system (R8RY0- for heating only). he R8RY versions include a low-energy consumption circulator complying with directive ErP 009//CE, interception ball s with integrated thermometer, check integrated in the return circuit and polypropylene foam rigid insulation (EPP). he R8RY are equipped with a mixing ; the actuator to control the mixing (when included) is sold separately. he mixing actuators and the delivery temperature can be controlled with KLIMAbus thermoregulation products. VIDEO Frame the QR code with your smartphone or tablet to view the video tutorial.

2 Versions and product codes PRODUC CODE APPLICAION DELIVERY/REURN OUPUS REVERSIBILIY CIRCULAOR MIXING VALVE MIXING ACUAOR (OPIONAL) R8RY0 Heating/Cooling Yes Wilo Para /7 - R8RY0 Heating/Cooling Yes Wilo Para /7 Ball mixing (R9) K7Y00/0/0 R8RY0 Heating/Cooling No Wilo Para /7 Sector mixing (R97) K7Y00/0/0 R8RY0 Heating only Yes Wilo Para /7 hermostatic mixing - R8RY Heating/Cooling Yes Not included - R8RY Heating/Cooling Yes Not included Ball mixing (R9) K7Y00/0/0 R8RY Heating/Cooling No Not included Sector mixing (R97) K7Y00/0/0 R8RY Heating only Yes Not included hermostatic mixing - Optional components K7Y00: actuator with integrated constant temperature regulator K7Y0: -point floating actuator controllable with KLIMAbus thermoregulation K7Y0: actuator with V regulation controllable with KLIMAbus thermoregulation R8Y0: differential by-pass kit RY00: interception ball F x nut / F, for installation upstream the distribution unit KLIMAbus thermoregulation: KLIMAbus thermoregulation components (regulation unit, thermostats, ambient probes, etc...) Compatible circulators (for circulator-free units) Wilo Para - 80 mm centre distance Grundfos Alpha series - interassse 80 mm General technical data Fluids: water, glycol-based solutions (max. 0 %) emperature range: 00 C ( 9 C for R8RY0-) Max. working pressure: bar or 0 bar depending on versions Connections: system side: F ISO 8 boiler side: / M ISO 8 outputs centre distance: mm Circulator Wilo Para /, 80 mm centre distance, complying with directive ErP 009//CE (for versions with circulator) Galvanized steel spacer, 80 mm centre distance (for circulator-free versions) Interception ball s with thermometers (scale 0 0 C) and connections for by-pass kit Check integrated on return circuit EPP insulation, density kg/m Wall-mount plate (screw anchors not included) NOE. Specific data referring to single R8R units are given in the following corresponding paragraph. Materials Interception ball s: CW7N brass body, PFE sealings, plastic handle Spacer with check : CW7N brass body, POM check Polypropylene foam insulation (EPP) Gaskets: EPDM

3 Components F F F F F F F F 7 BACK VIEW / M / M / M / M / M / M / M / M COMPONEN REFERENCE R8RY0 R8RY R8RY0 R8RY R8RY0 R8RY R8RY0 R8RY Brass fitting R9 mixing ball R97 mixing sector Mixing thermostatic Circulator Galvanized steel spacer Circulator Galvanized steel spacer Circulator Galvanized steel spacer Circulator Galvanized steel spacer Delivery ball, with thermometer and connections for by-pass kit Delivery ball, with thermometer and connections for by-pass kit Delivery ball, with thermometer and connections for by-pass kit Delivery ball, with thermometer and connections for by-pass kit Spacer with integrated check Spacer with integrated check Spacer with integrated check Spacer with integrated check Return ball, with thermometer and connections for by-pass kit Return ball, with thermometer and connections for by-pass kit Return ball, with thermometer and connections for by-pass kit Return ball, with thermometer and connections for by-pass kit Insulation shell Insulation shell Insulation shell Insulation shell 7 Wall-mount plate Wall-mount plate Wall-mount plate Wall-mount plate

4 Main features Delivery/return outputs reversibility R8RY units include reversible delivery and return outputs. R8RY0- units instead are not reversible. R8RY0- R8RY0- R8RY0- Invert delivery and return by fitting the outputs in the insulation slots. Invert delivery and return by fitting the outputs in the insulation slots. Also invert the cap and the copper fitting Invert delivery and return by fitting the outputs in the insulation slots and turn the mixing upside down. Check integrated on return output All R8R units include a check inside the brass spacer top, on the return output. he check can be disassembled by removing the Seeger ring used to fit it to the spacer. Installation of RY00 ball s R8R units can be intercepted by installing the RY00 ball s upstream. he ball s can be opened and closed using a mm Allen wrench. Check RY00 Installation of R8Y0 differential by-pass kit he differential by-pass kit protects the circulator enabling water recirculation inside the R8R unit when the secondary system is off or completely closed. he kit includes a brass spacer with integrated check calibrated at a fix value of mho, two nuts to be screwed on the interception s and two PFE gaskets. R8Y0 Gasket Check Nut

5 R8RY0 - R8RY Operation R8RY0 and R8RY distribution units without mixing are used in heating and cooling systems such as relaunching units for direct outputs of high/low temperature combined systems. he units include interception s with thermometer both on the delivery and return circuit and a check on the return spacer. he two delivery and return outputs are reversible and a R8Y0 differential by-pass kit can be installed in between (see paragraph Main characteristics ). b a a b Boiler room side System side Circulator (per R8RY0) or galvanized steel spacer (per R8RY) Check Interception ball with thermometer and by-pass kit connections Differential by-pass kit (optional) Specific technical data emperature range: 00 C Max. working pressure: 0 bar Connections: system side: F ISO 8 boiler side: / M ISO 8 outputs centre distance: mm Weight:,8 kg (with circulator);,0 kg (without circulator) Materials Interception ball s: CW7N brass body, PFE sealings, plastic handle Spacer with check : CW7N brass body, POM check Polypropylene foam insulation (EPP) Gaskets: EPDM Flow rate/power/hydraulic head diagram Hydraulic head [mh O] R8RY ,,, Flow rate [m /h] 0 t 0 Power [kw] 0 0 t 0 t 0 0 t 0 NOE. For proper interpretation of the diagram, see example on page. NOE. Curves obtained with circulator set to constant speed, level III mode.

6 R8RY0 - R8RY Operation R8RY0 and R8RY distribution units with R9 mixing ball can be used in heating and cooling systems to control the system delivery temperature. Operation is possible only when combined to an actuator and possibly a KLIMAbus thermoregulation system. he units include an interception with thermometer on both delivery and return circuits and a check on the return spacer. he two delivery and return outputs are reversible and a R8Y0 differential by-pass kit can be installed in between (see paragraph Main characteristics ). b a b Boiler room side System side Circulator (per R8RY0) or galvanized steel spacer (per R8RY) Specific technical data emperature range: 00 C Max. working pressure: 0 bar Connections: system side: F ISO 8 boiler side: / M ISO 8 outputs centre distance: mm Weight:,8 kg (with circulator);,0 kg (without circulator) Materials Interception ball s: CW7N brass body, PFE sealings, plastic handle Mixing : brass body, plastic handle, hard drawn copper pipe connecting delivery and return circuits, EPDM gaskets Spacer with check : CW7N brass body, POM check Polypropylene foam insulation (EPP) Gaskets: EPDM Flow rate/power/hydraulic head diagram 9 a B AB A M M Check Interception ball with thermometer and by-pass kit connections Differential by-pass kit (optional) Mixing with actuator Hydraulic head [mh O] 8 7 R8RY ,,, Flow rate [m /h] 0 t 0 NOE. For proper interpretation of the diagram, see example on page. NOE. Curves obtained with circulator set to constant speed, level III mode. Power [kw] t 0 t t 0 Kv R9 mixing Manual handle position 0 (B AB) (A AB) Kv (AB),0,8 7,8 9,8, 8,9

7 Actuator installation K7Y00 or K7Y0/0 actuators can be installed on R9 mixing s. Before closing the R8R unit with the front insulation shell, with a sharp-edge cutter carve out the shape of the K7 actuator (to make this operation easier, the shape of the actuator is reproduced on the back of the front insulation shell). Actuator installation K7Y0/0 on R9 mixing Use the Connection kit 09 included in the actuator package. Before installing the K7Y0/0 actuator on the R9 mixing, make sure the is in by-pass position (milling in OFF position) and the actuator is in closing position. For the K7Y0 actuator: With the body on the left and the by-pass -shaped fitting on the right, the DIP must be positioned on OFF (a). With the body on the right and the by-pass -shaped fitting on the left, the DIP must be positioned on ON (b). Connection kit GIACOMINI CODE: 09 a ON OFF K7Y0 b ON OFF K7Y0 K7Y0 Black: opening Blue: neutral Brown: closing K7Y0 Black: closing Blue: neutral Brown: opening 7

8 Actuator installation K7Y00 on R9 mixing Use the Connection kit 09 included in the actuator package. Before installing the K7Y00 actuator on the R9 mixing, make sure the is in by-pass position (milling in OFF position) and the actuator is in closing position. With the body on the left and the by-pass -shaped fitting on the right, the DIP must be positioned on OFF (a). With the body on the right and the by-pass -shaped fitting on the left, the DIP SYSEM must be positioned on ON (b). Connection kit GIACOMINI CODE: 09 a b ON OFF ON OFF NOE. When the DIP position is changed, actuator calibration begins. he LED blinks (x/sec) and the actuator is turned right and left. When this happens, leave the actuator in the AUO position, do not change the settings and do not cut off electric power. When calibrating the actuator, to protect the system, the circulator must be turned off to prevent temperature fluctuations in the system. Installation of temperature probes he temperature probe must be installed after the system circulator, at a max. distance of, m from the actuator. For contact installation, use the kit included with the actuator. his requires a flat surface with a min. length of 0 mm to position the probe. For immersion installation, the probe must be installed in a housing up to half of the piping diameter (the R7Y00 housing can be used by installing it in the ball sockets included with the R8R unit). his requires a suitable mechanic protection of the probe and probe wire. he wire must be insulated in case of contact with very hot parts. 8

9 R8RY0 - R8RY Operation R8RY0 and R8RY distribution units with R97 mixing sector can be used in heating and cooling systems to control the system delivery temperature. Operation is possible only when combined to an actuator and possibly a KLIMAbus thermoregulation system. he units include an interception with thermometer on both delivery and return circuits and a check on the return spacer. he mixing is also equipped with a manually adjustable by-pass to insert the function of fixed recirculation of the system. he two delivery and return outputs are NO reversible (see Main Characteristics paragraph) and a R8Y0 differential by-pass kit can be installed in between (see paragraph Main characteristics ). b a b Boiler room side System side Circulator (per R8RY0) or galvanized steel spacer (per R8RY) Check Specific technical data emperature range: 00 C Max. working pressure: 0 bar Connections: system side: F ISO 8 boiler side: / M ISO 8 outputs centre distance: mm Weight:,7 kg (with circulator);,9 kg (without circulator) Materials Interception ball s: CW7N brass body, PFE sealings, plastic handle Valvola miscelatrice: corpo in ottone, tubo di raccordo in ottone, Gaskets in EPDM, FPM e PFE. Spacer with check : CW7N brass body, POM check Polypropylene foam insulation (EPP) Gaskets: EPDM Flow rate/power/hydraulic head diagram Hydraulic head [mh O] R8RY0 a B AB A M M Interception ball with thermometer and by-pass kit connections Differential by-pass kit (optional) Mixing with actuator Mixing recirculation by-pass Power [kw] 0 0 0,,, Flow rate [m /h] 0 t t 0 t 0 t 0 NOE. For proper interpretation of the diagram, see example on page. NOE. Curves obtained with circulator set to constant speed, level III mode. 9

10 R97 mixing Kv Equal percentage : to absolute value variations of the stroke always corresponds the same % variation of the outflow coefficient (example: if the opens by 0 %, the Kv will vary by 0 %), notwithstanding the position of the recirculation by-pass. Operation of mixing recirculation by-pass R97 mixing s include a by-pass which activates a fix recirculation on the mixing (B AB). AB AB S S 0 B B Kv [m /h] 8 B AB A BY-PASS OFF A BY-PASS ON WARNING. Do not loosen the safety device (S) next to the by-pass adjustment screw. High pressures may violently eject it from its seat. A Opening stroke [%] Actuator installation K7Y00 or K7Y0 actuators can be installed on R97 mixing s. Before closing the R8R unit with the front insulation shell, with a sharp-edge cutter carve out the shape of the K7 actuator (to make this operation easier, the shape of the actuator is reproduced on the back of the front insulation shell). Actuator installation K7Y0/0 on R97 mixing Use the Connection kit 097 included in the actuator package. Before installing the K7Y0/0 actuator on the R97 mixing, make sure the is in by-pass position ( A notch downwards), the actuator is in closing position, put the indicator in position for a clockwise rotation and the DIP is in ON position for K7Y0. Connection kit ROOMIX CODE: 097 ON OFF K7Y0 K7Y0 BY-PASS A Black: closing Blue: neutral Brown: opening 0

11 Actuator installation K7Y00 on R97 mixing Use the Connection kit 097 included in the R8R package. Before installing the K7Y00 actuator on the R97 mixing, make sure the is in by-pass position ( A notch downwards), the actuator is in closing position and the DIP is in ON position. Connection kit ROOMIX CODE: 097 ON OFF BY-PASS A NOE. When the DIP position is changed, actuator calibration begins. he LED blinks (x/sec) and the actuator is turned right and left. When this happens, leave the actuator in the AUO position, do not change the settings and do not cut off electric power. When calibrating the actuator, to protect the system, the circulator must be turned off to prevent temperature fluctuations in the system. Installation of temperature probes he temperature probe must be installed after the system circulator at a max. distance of, m from the actuator. For contact installation use the kit included with the actuator. his requires a flat surface with a min. length of 0 mm to position the probe. For immersion installation, the probe must be installed in a housing up to half of the piping diameter (the R7Y00 housing can be used by installing it in the ball sockets included with the R8R unit). his requires a suitable mechanic protection of the probe and probe wire. he wire must be insulated in case of contact with very hot parts.

12 R8RY0 - R8RY Operation R8RY0 and R8RY distribution units with mixing thermostatic can be used in heating-only systems to control the system delivery temperature and maintain it at the desired constant temperature. he setting range of the mixing thermostatic allows for applications on low-temperature radiant systems and/ or fan-coil applications. he units include interception s with thermometer on both delivery and return circuits and a check on the return spacer. he two delivery and return outputs are reversible and the R8Y0 differential by-pass kit can be installed in between (see paragraph Main characteristics ). b a b Boiler room side System side Specific technical data emperature range: 9 C Max. working pressure: bar Connections: system side: F ISO 8 boiler side: / M ISO 8 outputs centre distance: mm Weight: 7,0 kg (with circulator);, kg (without circulator) Materials Interception ball s: CW7N brass body, PFE sealings, plastic handle Valvola miscelatrice: corpo in ottone, otturatore in PSU GF0, molla in acciaio inox, Gaskets in EPDM, sensore a cera. Spacer with check : CW7N brass body, POM check Polypropylene foam insulation (EPP) Gaskets: EPDM Flow rate/power/hydraulic head diagram Circulator (per R8RY0) or galvanized steel spacer (per R8RY) Check Interception ball with thermometer and by-pass kit connections Hydraulic head [mh O] R8RY0 a Differential by-pass kit (optional) 0 0 0,,, Flow rate [m /h] 0 t hermostatic mixing 0 Power [kw] 0 0 t 0 t 0 0 t 0 NOE. For proper interpretation of the diagram, see example on page. NOE. Curves obtained with circulator set to constant speed, level III mode.

13 hermostatic mixing Before closing the R8R unit with the front insulation shell, with a sharp-edge cutter carve the side to adjust the position of the mixing thermostatic handwheel (to make this operation easier, the shape of the handwheel is reproduced on the side of the front insulation shell). Kv:, Sensitivity: ± C Handwheel position Min. Max. emperature [ C] Dimensions B B Ø0 L E F Ø0 G I H A C D A PRODUC CODE A x B C [mm] D [mm] E [mm] F [mm] G [mm] H [mm] I [mm] L [mm] R8RY0 R8RY0 R8RY0 R8RY0 R8RY / M x F R8RY R8RY R8RY

14 Example of application diagram Application diagram for heating-only system with R8SEP complete of R8RY0 for high-temperature radiator zone + R8RY0/0 for low-temperature radiant system zone and mixing actuator controlled by KLIMAbus thermoregulation..a. KLIMAbus.A. R8R R8SEP

15 Interpretation of flow rate/power/hydraulic head diagram With the system Power and Δt project data known, trace a horizontal line starting from the Power axis up to intersecting the required Δt (A). From the obtained intersection point, trace a vertical line up to intercepting the operational curve of the R8R unit (B), this will show the operational flow rate and hydraulic head available downstream the R8R unit (B, C). Example: Power = 0 kw Δt = 0 C he indications given above will result in a flow rate equal to,7 m /h with a useful hydraulic head at the circulator of,8 mh O. NOE. Curves obtained with circulator set to constant speed, level III mode. 9 8 Hydraulic head [mh O] 7 R8RY0,8 mh O C B 0 0,7 m /h 0 0,,, Flow rate [m /h] t Power [kw] A t 0 t 0 t 0 Power Δt Flow rate Hydraulic head R8R unit curve Power required by the heating/cooling system zone downstream of the R8R distribution unit emperature difference between delivery and return of the heating/cooling system zone downstream of the R8R distribution unit (Δt depends on the type of system) Operational flow rate downstream of the R8R distribution unit Hydraulic head available downstream of the R8R distribution unit Operational curve of the R8R distribution unit (Wilo Yonos Para circulator + all various components)

16 Standards reference PED 0/8/EU, article. LVD 0//EU EMC 0/0/EU RoHS 0//EU ErP 009//CE ErP 0 Product specifications R8RY0 Distribution unit to control heating and cooling of one system zone. Connections: system side F ISO 8; boiler side / M ISO 8; delivery and return outputs centre distance mm. Includes: brass delivery output equipped with lowenergy consumption circulator complying with directive ErP 009//CE (centre distance 80 mm) and interception ball with integrated thermometer (0 0 C scale); brass return output equipped with interception ball with integrated thermometer (0 0 C scale) and POM check. Reversible delivery and return outputs. EPP rigid insulation (density kg/m). Wall-mount plate (screw anchors not included). EPDM gaskets. emperature range 00 C. Max. working pressure 0 bar. Weight,8 kg. Optional installation of differential by-pass kit between the two delivery and return outputs. Optional installation of interception ball upstream of distribution unit. R8RY Distribution unit to control heating and cooling of one system zone. Connections: system side F ISO 8; boiler side / M ISO 8; delivery and return outputs centre distance mm. Includes: brass delivery output equipped with spacer to install circulator (centre distance 80 mm) and interception ball with integrated thermometer (0 0 C scale); brass return output equipped with interception ball with integrated thermometer (0 0 C scale) and POM check. Reversible delivery and return outputs. EPP rigid insulation (density kg/m). Wall-mount plate (screw anchors not included). EPDM gaskets. emperature range 00 C. max. working pressure 0 bar. Weight,0 kg. Optional installation of differential by-pass kit between the two delivery and return outputs. Optional installation of interception ball upstream of distribution unit. R8RY0 Distribution unit to control heating and cooling of one system zone. Connections: system side F ISO 8; boiler side / M ISO 8; delivery and return outputs centre distance mm. Includes: brass delivery output equipped with low-energy consumption circulator complying with directive ErP 009//CE (centre distance 80 mm), interception ball with integrated thermometer (0 0 C scale) and motorizable mixing ball ; brass return output equipped with interception ball with integrated thermometer (0 0 C scale) and POM check. Reversible delivery and return outputs. EPP rigid insulation (density kg/m). Wall-mount plate (screw anchors not included). EPDM gaskets. emperature range 00 C. Max. working pressure 0 bar. Weight,8 kg. Optional installation of differential by-pass kit between the two delivery and return outputs. Optional installation of interception ball upstream of distribution unit. Optional installation of the mixing actuator controllable by KLIMAbus thermoregulation items. R8RY Distribution unit to control heating and cooling of one system zone. Connections: system side F ISO 8; boiler side / M ISO 8; delivery and return outputs centre distance mm. Includes: brass delivery output equipped with spacer to install circulator (centre distance 80 mm), interception ball with integrated thermometer (0 0 C scale) and motorizable mixing ball ; brass return output equipped with interception ball with integrated thermometer (0 0 C scale) and POM check. Reversible delivery and return outputs. EPP rigid insulation (density kg/m). Wall-mount plate (screw anchors not included). EPDM gaskets. emperature range 00 C. Max. working pressure 0 bar. Weight,0 kg. Optional installation of differential by-pass kit between the two delivery and return outputs. Optional installation of interception ball upstream of distribution unit. Optional installation of the mixing actuator controllable by KLIMAbus thermoregulation items.

17 R8RY0 Distribution unit to control heating and cooling of one system zone. Connections: system side F ISO 8; boiler side / M ISO 8; delivery and return outputs centre distance mm. Includes: brass delivery output equipped with low-energy consumption circulator complying with directive ErP 009//CE (centre distance 80 mm), interception ball with integrated thermometer (0 0 C scale) and motorizable sector mixing equipped with optional fix by-pass; brass return output equipped with interception ball with integrated thermometer (0 0 C scale) and POM check. Reversible delivery and return outputs. EPP rigid insulation (density kg/m). Wall-mount plate (screw anchors not included). EPDM. gaskets emperature range 00 C. Max. working pressure 0 bar. Weight,7 kg. Optional installation of differential by-pass kit between the two delivery and return outputs. Optional installation of interception ball upstream of distribution unit. Optional installation of mixing actuator controllable by KLIMAbus thermoregulation items. R8RY Distribution unit to control heating and cooling of one system zone. Connections: system side F ISO 8; boiler side / M ISO 8; delivery and return outputs centre distance mm. Includes: brass delivery output equipped with spacer to install circulator (centre distance 80 mm), interception ball with integrated thermometer (0 0 C scale) and motorizable sector mixing equipped with optional fix by-pass; brass return output equipped with interception ball with integrated thermometer (0 0 C scale) and POM check. Reversible delivery and return outputs. EPP rigid insulation (density kg/m). Wall-mount plate (screw anchors not included). EPDM gaskets. emperature range 00 C. Max. working pressure 0 bar. Weight,9 kg. Optional installation of differential by-pass kit between the two delivery and return outputs. Optional installation of interception ball upstream of distribution unit. Optional installation of mixing actuator controllable by KLIMAbus thermoregulation items. R8RY0 Distribution unit to control heating and cooling of one system zone. Connections: system side F ISO 8; boiler side / M ISO 8; delivery and return outputs centre distance mm. Includes: brass delivery output equipped with low-energy consumption circulator complying with directive ErP 009//CE (centre distance 80 mm), interception ball with integrated thermometer (0 0 C scale) and thermostatic mixing ; brass return output equipped with interception ball with integrated thermometer (0 0 C scale) and POM check. Reversible delivery and return outputs. EPP rigid insulation (density kg/m). Wall-mount plate (screw anchors not included). EPDM gaskets. emperature range 9 C. Max. working pressure bar. Weight 7,0 kg. Optional installation of differential by-pass kit between the two delivery and return outputs. Optional installation of interception ball upstream of distribution unit. R8RY Distribution unit to control heating and cooling of one system zone. Connections: system side F ISO 8; boiler side / M ISO 8; delivery and return outputs centre distance mm. Includes: brass delivery output equipped with spacer for to install circulator (centre distance 80 mm), interception ball with integrated thermometer (0 0 C scale) and thermostatic mixing ; brass return output equipped with interception ball with integrated thermometer (0 0 C scale) and POM check. Reversible delivery and return outputs. EPP rigid insulation (density kg/m). Wall-mount plate (screw anchors not included). EPDM gaskets. emperature range 9 C. Max. working pressure bar. Weight, kg. Optional installation of differential by-pass kit between the two delivery and return outputs. Optional installation of interception ball upstream of distribution unit. Safety Warning. Installation, commissioning and periodical maintenance of the product must be carried out by qualified operators in compliance with national regulations and/or local standards. A qualified installer must take all required measures, including use of Individual Protection Devices, for his and others safety. An improper installation may damage people, animals or objects towards which may not be held liable. Package Disposal. Carton boxes: paper recycling. Plastic bags and bubble wrap: plastic recycling. Additional information. For more information, go to giacomini.com or contact our technical assistance service. his document provides only general indications. may change at any time, without notice and for technical or commercial reasons, the items included herewith. he information included in this technical sheet do not exempt the user from strictly complying with the rules and good practice standards in force. Product Disposal. Do not dispose of product as municipal waste at the end of its life cycle. Dispose of product at a special recycling platform managed by local authorities or at retailers providing this type of service. 7

R146C. Adjustable magnetic dirt separator. Versions and product codes. Datasheet 0840EN 10/2018

R146C. Adjustable magnetic dirt separator. Versions and product codes. Datasheet 0840EN 10/2018 R146C Adjustable magnetic dirt separator Datasheet 0840EN 10/2018 The R146C adjustable magnetic dirt separator separates and removes debris inside hydraulic circuits of modern heating and cooling systems.

More information

R557R EN January 2012

R557R EN January 2012 R7R- 077EN January 0 07U 00 00 00 WITH HIGH TEMPERATURE MANIFOLDS Example: R7RY0 + RAY00 R7R- WITH THERMAL ENERGY METERING Description R7R- group is used for the regulation of the fixed point heating for

More information

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function Thermostatic regulating unit for heating systems 66 series ACCREDITED ISO 9 FM 6 8/7 GB replaces dp 8/ GB Function The thermostatic regulating unit performs the function of keeping the flow temperature

More information

Mercury Mixing Kit (Code: ME1053)

Mercury Mixing Kit (Code: ME1053) Mercury Mixing Kit (Code: ME1053) The installation and commissioning of the UFH mixing kit system must be exclusively performed by qualified personnel in accordance with the national guidelines and/or

More information

DEVIATING VALVES ART K063

DEVIATING VALVES ART K063 FUNCTION The flow diverter valve Art.307 makes it possible to supply a branch circuit. Prepared to receive our electro-thermal controls Art. 978, 979, 980 or our thermostatic heads with remote sensor Art.

More information

Metering systems 0548EN April 2014

Metering systems 0548EN April 2014 08EN April 0 0U8 GEY - Y - Y (GE- series) 900 000/ 00 00A/ 800 00L/ Versions and product codes Product code Type Heat exchanger nominal power GEY, - GEY and production GEY and production Table - Product

More information

4-way valve with thermostatic option with variable centre distance and pre-adjustment for Single pipe and Dual pipe systems.

4-way valve with thermostatic option with variable centre distance and pre-adjustment for Single pipe and Dual pipe systems. 4-way valve with thermostatic option with variable centre distance and pre-adjustment for Single pipe and Dual pipe systems. CT3101.0_00 EN June 2016 o o o o Valve with pre-adjustment; Variable centre

More information

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES FUNCTION Thermostatic expansion valves are used to regulate and cut-off the flow of the heat transfer fluid that circulates inside airconditioning system terminals (radiators, fan coils, etc.). Thermostat

More information

THERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES

THERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES ST.07.05.00 THERMOSTIC SINGLE-PIPE AND DOUBLE-PIPE VALVES 1. Art.1420 THERMOSTIC SINGLE-PIPE VALVE Single-pipe valves allow manual, thermostatic or thermo-electric regulation. Separation of the lockshield

More information

RADIANT PANEL SYSTEM CONTROL QUICK GUIDE

RADIANT PANEL SYSTEM CONTROL QUICK GUIDE RADIANT PANEL CONTROL QUICK GUIDE 05 RADIANT PANEL CONTROL Terms and definitions The system temperature regulation can be carried out in only two basic ways: Flow rate control of the medium feeding the

More information

ACCREDITED. Product range Code A2L Pre-assembled set point temperature regulating unit with manifolds and box, with UPM3 Auto L pump

ACCREDITED. Product range Code A2L Pre-assembled set point temperature regulating unit with manifolds and box, with UPM3 Auto L pump Set point temperature regulating unit series ACCREDITED ISO 9 FM / GB replaces dp / GB Function The temperature regulating unit is made to be used in radiant panel systems, in combination with distribution

More information

CALEFFI. Modulating temperature regulating unit for heating and cooling with high temperature distribution kit. series /04 GB.

CALEFFI. Modulating temperature regulating unit for heating and cooling with high temperature distribution kit. series /04 GB. Modulating temperature regulating unit for heating and cooling with high temperature distribution kit series cert. n ISO / GB Function The modulating temperature regulating unit with high temperature distribution

More information

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES FUNCTION Thermostatic expansion valves are used to regulate and cut-off the flow of the heat transfer fluid that circulates inside airconditioning system terminals (radiators, fan coils, etc.). Thermostat

More information

Convertible radiator valve for one-pipe systems, centre distance 35 mm

Convertible radiator valve for one-pipe systems, centre distance 35 mm Convertible radiator valve for one-pipe systems, centre distance 35 mm 56 series ACCREDITED ISO 900 FM 65 033/6 GB Function 56 series convertible radiator valves are used on one-pipe radiator systems.

More information

CALEFFI. Anti-condensation recirculation and distribution unit. 281 series 01224/14 GB. Replaces dp 01224/12 GB. Function

CALEFFI. Anti-condensation recirculation and distribution unit. 281 series 01224/14 GB. Replaces dp 01224/12 GB. Function Anti-condensation recirculation and distribution unit 8 series ACCREDITED ISO 900 FM 654 ISO 900 No. 000 CALEFFI 04/4 GB Replaces dp 04/ GB GB Function The anti-condensation recirculation and distribution

More information

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB 4 RESET ON DHW CH FAULT SATK wall-mounted heat interface unit Fitted for connection to DHW storage SATK4 series ACCREDITED CALEFFI 6/4 GB ISO 9 FM 64 ISO 9 No. The latest generation of heat interface units

More information

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve Connection and energy management compact unit 2850 series ACCREDITED CALEFFI 01259/14 GB ISO 9001 FM 21654 ISO 9001 No. 0003 Function The connection and energy management compact unit enables combining

More information

DIRECT AND INDIRECT THERMAL ENERGY METERING

DIRECT AND INDIRECT THERMAL ENERGY METERING Chapter 7 DIRECT AND INDIRECT THERMAL ENERGY METERING User modules for direct metering 232 Heat interface units for direct metering 236 Thermal energy meters, water maters, data centralization system 243

More information

ACCREDITED. Product range Code A2L Modulating temperature regulating unit for heating and cooling, with ALPHA2 L pump.

ACCREDITED. Product range Code A2L Modulating temperature regulating unit for heating and cooling, with ALPHA2 L pump. Modulating temperature regulating unit for heating and cooling 7 series ACCREDITED ISO FM ا ٠١١٥٢/١٥ replaces /7 GB Function The temperature regulating unit is made to be used in radiant panel systems

More information

Solar heating systems

Solar heating systems 03 energy efficiency Compact, "ALL-IN-ONE" solar system Solar panel for swimming pools Hydraulic components Drain-Unit: dual hydraulic unit with drain back system Drain-Unit: hydraulic unit with drain-back

More information

Protection and Control of Solid Fuel Boilers

Protection and Control of Solid Fuel Boilers Protection and Control of Solid Fuel Boilers thermal relief valves thermostatic valves and pump stations draft regulators www.regulus.eu BOILER PROTECTION AGAINST OVERHEATING Solid fuel boilers may get

More information

CALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB

CALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB Set point thermostatic regulating unit 8 series FM 65 00 CALEFFI 090/8 GB replaces dp 090/5 GB Function The thermostatic regulating unit is made to be used in radiant panel systems, in combination with

More information

THERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE PRODUCTION RANGE IRON PIPE CODE CONNECTION

THERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE PRODUCTION RANGE IRON PIPE CODE CONNECTION THERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE CT0031.0_10 EN August 2016 THERMOSTATIC RADIATOR VALVES * * * * 028 * LICENSED USE OF TRADEMARK NR. 43 PRODUCTION RANGE IRON

More information

PRE-ASSEMBLED MANIFOLD FOR HEATING SYSTEMS WITH THERMOSTATIC MIXING

PRE-ASSEMBLED MANIFOLD FOR HEATING SYSTEMS WITH THERMOSTATIC MIXING PRE-ASSEMBLED MANIFOLD FOR HEATING SYSTEMS WITH THERMOSTATIC MIXING R557 SUMMARY 1. APPLICATION 1. OPERATING 2. COMPONENTS 3. OVERALL DIMENSIONS 4. APPLICATION EXAMPLE 6. POSITIONING OF THE HEAD WITH THERMOSTATIC

More information

Chapter 7 DIRECT AND INDIRECT THERMAL ENERGY METERING

Chapter 7 DIRECT AND INDIRECT THERMAL ENERGY METERING Chapter 7 DIRECT AND INDIRECT THERMAL ENERGY METERING 7 216 USER MODULES FOR DIRECT METERING GE555 STANDARD CONNECTIONS DIMENSIONS (L x H x D) mm BALANCING UNITS FOR SANITARY WATER METERS GE555Y461 3/4

More information

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production SATK0 - SATK0 series ACCREDITED ISO 900 FM 009/ GB replaces dp 009/ GB Function The latest generation of Heat Interface

More information

caleffi hydronic valves page 1 of 12

caleffi hydronic valves page 1 of 12 caleffi hydronic valves page 1 of 12 page 2 of 12 MANUAL RADIATOR VALVES 1601811 - Series 340 1601812 - Series 341 1603748 - Seies 411 1603749 - Series 412 CONVERTIBLE RADIATOR VALVES 1601816 - Series

More information

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold Dynalux Floor Heating Manifolds Underfl oor heating circuit manifold IMI HEIMEIER / Floor Heating Control / Dynalux Dynalux Dynalux adjusts the flow rate in the individual heating circuits directly in

More information

CALEFFI. Anti-condensation circulation unit. 282 series 01225/14 GB. replaces dp 01225/11. Code completion Setting 45 C 55 C 60 C 70 C.

CALEFFI. Anti-condensation circulation unit. 282 series 01225/14 GB. replaces dp 01225/11. Code completion Setting 45 C 55 C 60 C 70 C. Anti-condensation circulation unit 8 series ACCREDITED ISO 9 F 654 ISO 9 No. CALEFFI 5/4 GB replaces dp 5/ Function The anti-condensation circulation unit performs the function of connecting the solid

More information

Data Sheet. Compact Mixing Shunt for Floor Heating, FHM-Cx. Application:

Data Sheet. Compact Mixing Shunt for Floor Heating, FHM-Cx. Application: Data Sheet Compact Mixing Shunt for Floor Heating, FHM-Cx Application: FHM-C1 Mixing shunt FHM-C/ FHM-C Mixing shunt FHM-C Mixing shunt FHM-C The Danfoss floor heating compact mixing shunts are used for

More information

FHM-Cx Mixing Shunts for Floor Heating

FHM-Cx Mixing Shunts for Floor Heating FHM-Cx Mixing Shunts for Floor Heating Application Mixing shunt FHM-C5/C6 (UPS pump) The Danfoss compact mixing shunts are used for regulation of flow and supply temperature in hydronic floor heating systems.

More information

281 Series. ThermoBloc boiler protection recirculation and distribution unit. Installation, commissioning and servicing instructions

281 Series. ThermoBloc boiler protection recirculation and distribution unit.   Installation, commissioning and servicing instructions www.caleffi.com NA1094.01 ThermoBloc boiler protection recirculation and distribution unit Copyright 013 Caleffi Installation, commissioning and servicing instructions 81 Series Function The ThermoBloc

More information

HERZ Differential Pressure Control Valve 4002

HERZ Differential Pressure Control Valve 4002 HERZ Differential Pressure Control Valve 4002 Data sheet 4002, Issue 0118 Dimensions in mm B1 B2 1 4002 41 1 4002 61 1 4002 71 1 4002 42 1 4002 62 1 4002 72 1 4002 43 1 4002 63 1 4002 73 1 4002 44 1 4002

More information

CALEFFI. Solar storage-to-boiler thermostatic connection kit series 01164/09 GB. Function

CALEFFI. Solar storage-to-boiler thermostatic connection kit series 01164/09 GB. Function Solar storage-to-boiler thermostatic connection kit 6-63 series REGI STERED BS EN ISO 900:000 Cert. n FM 64 UNI EN ISO 900:000 Cert. n 0003 CLEFFI 064/09 GB Function The solar storage-to-boiler connection

More information

AIRTERM DIRT AND AIRTERM MAG COMBINED SELF-CLEANING DIRT SEPARATORS / DEAERATORS

AIRTERM DIRT AND AIRTERM MAG COMBINED SELF-CLEANING DIRT SEPARATORS / DEAERATORS AIRTERM DIRT AND AIRTERM MAG COMBINED SELF-CLEANING DIRT SEPARATORS / DEAERATORS CT2831.0_00 EN April 2015 * Airterm Dirt Airterm Mag * o Removes any impurity o Self-cleaning o Ensures system efficiency

More information

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Reduced Installation time Precision regulation Minimal tooling required 100% tested prior to packaging High quality

More information

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE SPECIFICATIONS... 1 OVERVIEW... 2 PRECAUTIONS... 2 MOUNTING LOCATION... 2 CONNECTION TO BOILER PRIMARY PIPING:... 3 ELECTRICAL CONNECTION... 4 FLUSHING THE

More information

Section - A. Radiator Valves

Section - A. Radiator Valves Section - Radiator Valves RDITOR VLVES EXMPLE OF PPLICTION 2 6 9 3 5 7 1 4 8 2 1 Thermostat adaptable valves. 2 Lockshield valves. 3 4-way thermostat adaptable valves for one-pipe and two-pipe systems.

More information

GENERAL CATALOGUE MICROMETRIC, THERMOSTATIC VALVES THERMOSTATIC VALVES MANUAL VALVES LOCKSHIELDS ACCESSORIES AND SPARE PARTS

GENERAL CATALOGUE MICROMETRIC, THERMOSTATIC VALVES THERMOSTATIC VALVES MANUAL VALVES LOCKSHIELDS ACCESSORIES AND SPARE PARTS GENERAL CATALOGUE MICROMETRIC, TERMOSTATIC VALVES TERMOSTATIC VALVES MANUAL VALVES LOCKSIELDS ACCESSORIES AND SPARE PARTS SUMMARY 1. USE 2. MICROMETRIC TERMOSTATIC VALVES 3. TECNICAL DATA 3. MATERIALS

More information

Roth fixed-value control set with high-efficiency pump

Roth fixed-value control set with high-efficiency pump Energy Systems Roth fixed-value control set with high-efficiency pump Assembly Instructions Living full of energy Contents General information Intended use 3 Benefits 3 Layout/Components 3 Installation/Electrical

More information

Function series Thermo-electric actuator electric supply 230 V (ac) or 24 V (ac/dc)

Function series Thermo-electric actuator electric supply 230 V (ac) or 24 V (ac/dc) onvertible radiator valve for one-pipe and two-pipe systems series ARIT 0/ G ISO 0 M ISO 0 No. 000 unction The series convertible radiator valve can be used both on one-pipe and two-pipe radiator systems.

More information

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage Model: 1090 1 Safety instructions Float-Controlled Condensate Trap, PN 16 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically lead to termination

More information

Systems for central heating

Systems for central heating www.far.eu Highlight Systems and Components for central heating Components for renewable energy systems Pressfar Fittings Presetting valves and thermostatic head Balancing devices Zone valves Metering

More information

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function HERZ-3000 Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function Standard Sheet for 3791 3792 Edition 1000 (0999) Dimensions in mm 1 3001 01 Cone sleeve 1 3002 01 Connection

More information

CONTROL UNIT FOR UNDERFLOOR HEATING SYSTEMS

CONTROL UNIT FOR UNDERFLOOR HEATING SYSTEMS ST.04.04.00 ONTROL UNIT FOR UNERFLOOR HETING SYSTEMS Low temperature control unit Low+high temperature control unit 1. ONTROL UNIT PPLITION The FR control unit is suitable for systems combining both high

More information

CS TSV MIX REGULUS PUMP STATION - for boilers and heating systems

CS TSV MIX REGULUS PUMP STATION - for boilers and heating systems Instruction Manual CS TSV MIX REGULUS PUMP STATION - for boilers and heating systems EN v 1.1 CONTENTS: 1 Introduction 3 2 Connection dimensions of CS TSV MIX Regulus 3 3 Function description of CS TSV

More information

CS TSV MIX-REGULUS CS TSV MIX REGULUS. Installation and Operation Manual CS TSV MIX REGULUS PUMP STATION - for boilers and heating systems

CS TSV MIX-REGULUS CS TSV MIX REGULUS. Installation and Operation Manual CS TSV MIX REGULUS PUMP STATION - for boilers and heating systems www.regulus.eu CS TSV MIX-REGULUS Installation and Operation Manual CS TSV MIX REGULUS PUMP STATION - for boilers and heating systems EN CS TSV MIX REGULUS CONTENTS: 1 Introduction 3 2 Connection dimensions

More information

TS RD 7761 RD, 7761 RD

TS RD 7761 RD, 7761 RD 1/2 HERZ Calis TS RD three way valve HERZ Calis TS RD 100% three-way valve for heating and cooling Datasheet for 1 7761 RD, Issue 0716 Dimensions in mm Order number Dimension R A B C kvs dp (bar) maximum

More information

Components for solar heating systems

Components for solar heating systems solarorkli Components for solar heating systems Components for heating and plumbing Components for solar heating systems Manifolds and distribution equipment Thermostatic valves Manual valves Motorised

More information

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40 1 Safety instructions Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically

More information

Partner Valve/High Quality Ball Valve LENO MSV-S

Partner Valve/High Quality Ball Valve LENO MSV-S Partner Valve/High Quality Ball Valve LENO MSV-S Description LENO MSV-S is a partner valve for all manual balancing valves in the LENO family. LENO MSV- S can also be applied as a high quality ball valve.

More information

Thermostatic mixing valves with replaceable cartridge for centralized systems

Thermostatic mixing valves with replaceable cartridge for centralized systems Thermostatic mixing valves with replaceable cartridge for centralized systems series REGISTERED BS EN ISO 9: Cert. n FM UNI EN ISO 9: Cert. n / N Replaces /9 N Function The thermostatic mixing valve is

More information

Installation and operation instructions Solar stations SolarBloC midi Premium DN 20 SolarBloC maxi Premium DN 25

Installation and operation instructions Solar stations SolarBloC midi Premium DN 20 SolarBloC maxi Premium DN 25 PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: info@paw.eu, Web: www.paw.eu Installation and operation instructions Solar stations SolarBloC

More information

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA Thermostatic mixing valves with replaceable cartridge for centralized systems 3, 3 series CCREDITED ISO 9 FM ISO 9 No. 3 /3 N Replaces / N Function The thermostatic mixing valve is used in systems producing

More information

manifold, for radiators

manifold, for radiators MMA, for radiators Eco-friendly materials, low lead content Quiet Precise and linear Dimension: DN 0 Temperature: C to + C Pressure class: PN 0 Description Area of use The Evoflow radiator is especially

More information

Model T-45NL: Certified in compliance with ASSE 1017, 1069, 1070, and ANSI/NSF 61 PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING AND OPERATING!

Model T-45NL: Certified in compliance with ASSE 1017, 1069, 1070, and ANSI/NSF 61 PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING AND OPERATING! Application Legend thermostatic mixing valves are designed for applications requiring temperature control, scald prevention and reduction of thermal shock in domestic potable water distribution (Model

More information

Thermostatic head with wax sensor

Thermostatic head with wax sensor Combined with valves covered by EN215 01 november 2004 ı Technical communication n da Use In modern society research concerning comfort in the home becomes a factor of prime importance. In order to obtain

More information

HANDBOOK REGULATOR VALVES. Ed REGULATOR VALVES RP-ED 01/ ENG 1

HANDBOOK REGULATOR VALVES. Ed REGULATOR VALVES RP-ED 01/ ENG 1 HANDBOOK Ed. 2017 RP-ED 01/2017 - ENG 1 DIRECTIVE 2014/68/EU ISSUED OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 15 MAY 2014 ON PRESSURE EQUIPMENT Directive 2014/68/EU (PED Recast) applies to the design,

More information

FHM-Cx Mixing Shunts for Floor Heating

FHM-Cx Mixing Shunts for Floor Heating Data Sheet FHM-Cx Mixing Shunts for Floor Heating Application A self-acting proportional regulator is used to regulate the supply temperature. The regulator ensures that the desired supply temperature

More information

Series 1140 and 1141 Temperature Regulators

Series 1140 and 1141 Temperature Regulators Hoffman Specialty Installation & Maintenance Instructions HS-504(E) Series 1140 and 1141 Temperature Regulators! CAUTION FOLLOW ALL INSTALLATION AND OPERATING INSTRUCTIONS. TURN OFF WATER OR STEAM BEFORE

More information

Model: 1100 Float-Controlled Condensate Trap, PN 25

Model: 1100 Float-Controlled Condensate Trap, PN 25 1 Safety instructions Model: 1100 Float-Controlled Condensate Trap, PN 25 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically lead to termination

More information

Thermostatic mixing valves with interchangeable cartridges

Thermostatic mixing valves with interchangeable cartridges www.caleffi.com R37. Thermostatic mixing valves with interchangeable cartridges Installation, commissioning and servicing instructions 3 Series Function The thermostatic mixing valve is used in systems

More information

Trade Product List 2013 BIOMASS ACCESSORIES

Trade Product List 2013 BIOMASS ACCESSORIES Trade Product List 2013 BIOMASS ACCESSORIES BIOMASS SYSTEM COMPONENTS Constant Temperature Control Accessories CONSTANT TEMPERATURE CONTROL PRODUCTS Order Code Description of Package and Contents Pictures

More information

Technical Product Guide

Technical Product Guide FMU - Floor Mixing Unit Boxed set pre-assembled for immediate installation: The FMU Floor Mixing Unit integrates both temperature and flow management, making the single piece unit very easy to install,

More information

521 Series. MixCal adjustable three-way thermostatic mixing valve. Installation, commissioning and service instructions

521 Series.  MixCal adjustable three-way thermostatic mixing valve. Installation, commissioning and service instructions MixCal adjustable three-way thermostatic mixing valve 37. www.caleffi.com Copyright 15 Caleffi 51 Series Installation, commissioning and service instructions Function The Caleffi MixCal three-way thermostatic

More information

RENEWABLE ENERGY THERMAL SOLAR ENERGY. RENEWABLE ENERGY...pag. 05

RENEWABLE ENERGY THERMAL SOLAR ENERGY. RENEWABLE ENERGY...pag. 05 THERMAL SOLAR ENERGY CATALOGUE OCTOBER 2008 INDEX RENEWABLE ENERGY THERMAL SOLAR ENERGY RENEWABLE ENERGY...pag. 05 SISTEMA CS 25 RN TAU... pag. 6 SISTEMA CS 25 RN - CS 25 RN PLUS... pag. 8 SISTEMA CSL

More information

PTG series valves 0490EN June 2018 Valves with thermostatic option for radiators, with presetting

PTG series valves 0490EN June 2018 Valves with thermostatic option for radiators, with presetting PT series valves 090E une 08 R0PT R0PT RPT RPT R0PT RPT escription The PT valves with thermostatic option and presetting are used to slice the delivery water flow rate in a radiator. hen the special worksite

More information

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve VENT APPENDIX A: PIPING SYMBOL LEGEND GENERIC COMPONENTS CALEFFI COMPONENTS circulator circulator w/ ThermoBloc union circulator w/ swing check spring loaded balancing balancing w/ gate check globe s purging

More information

VSL II QUICK START GUIDE

VSL II QUICK START GUIDE This Quick Start Guide must be left with owner and should be hung on or adjacent to the boiler for reference. VSL II QUICK START GUIDE DIRECT-VENT SEALED COMBUSTION CONDENSING BOILER ~ GAS-FIRED BOILER

More information

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341

5231 Series.   Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341 NA31 www.caleffi.com Low Lead High Flow Thermostatic Mixing Valves Copyright 1 Caleffi Installation, commissioning and service instructions Function 531 Series ASSE 17 model 531 series high flow thermostatic

More information

Flush individual room control for floor heating systems

Flush individual room control for floor heating systems Multibox Flush individual room control for floor heating systems Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGiNEERiNG ADVANTAGE Multibox is used for decentralized control

More information

BOILER COMPLETE FORCED CIRCULATION SYSTEMS. solair. Inspired by the sun. Save your energy.

BOILER COMPLETE FORCED CIRCULATION SYSTEMS. solair. Inspired by the sun. Save your energy. BOILER COMPLETE FORCED CIRCULATION SYSTEMS solair Inspired by the sun. Save your energy. FORCED CIRCULATION SYSTEM 00lt Dual Circulation Pump 00lt Forced Circulation System 0 0 Vertical Enameled Tank 00lt

More information

We regulate and supply clean energy

We regulate and supply clean energy Bonetti Rubinetterie Valduggia S.r.l. Language English Home The Company News Contacts Download International M2 MIX33 - DN32 We regulate and supply clean energy 2-Way pump unit with 3-way mixing valve

More information

SuperKlean Washdown Products

SuperKlean Washdown Products February 2012 DURAMIX 8000 INSTALLATION AND MAINTENANCE INSTRUCTIONS **DO NOT THROW AWAY AFTER INSTALLATION** **SAVE AND DISPLAY PROMINENTLY WHERE THIS EQUIPMENT IS USED** WARNING HIGH PRESSURE AND HOT

More information

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

SOLENOID VALVES FOR REFRIGERATING SYSTEMS SOLENOID VALVES FOR REFRIGERATING SYSTEMS APPLICATIONS The solenoid valves, shown in this chapter, are classified Pressure accessories in the sense of the Pressure Equipment Directive 97/23/EC, Article

More information

Metering systems 0371EN July 2016 User satellites, GE556 series Versions GE556Y301, GE556Y302

Metering systems 0371EN July 2016 User satellites, GE556 series Versions GE556Y301, GE556Y302 071N July 01 Versions GY01, GY0 igure 1 GY01 GY0 Description The G user satellites are the ideal metering solution in condominium systems with the centralised production of heating water and zone-based

More information

Control valves for floor heating systems. Floor Heating Manifolds

Control valves for floor heating systems. Floor Heating Manifolds Control valves for floor heating systems Floor Heating Manifolds IMI HEIMEIER / Floor Heating Control / Control valves for floor heating systems Control valves for floor heating systems Supply control

More information

Mikrotherm. Manual Radiator Valves With presetting

Mikrotherm. Manual Radiator Valves With presetting Mikrotherm Manual Radiator Valves With presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Mikrotherm Mikrotherm The Mikrotherm manual radiator valve is used in warm water pump heating systems,

More information

Operating Manual. Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN Safety instructions. 2 General description and use

Operating Manual. Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN Safety instructions. 2 General description and use 1 Safety instructions 1.1 Proper use Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN 100 Any improper use, intervention in the design and deviation from the design data automatically

More information

Multibox. Floor Heating Controller Flush individual room control for floor heating systems

Multibox. Floor Heating Controller Flush individual room control for floor heating systems Multibox Floor Heating Controller Flush individual room control for floor heating systems IMI HEIMEIER / Floor Heating Control / Multibox Multibox K, RTL and K-RTL Multibox K, RTL and K-RTL is used for

More information

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION ECO-FRIENDLY REFRIGERANT GAS INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the result of many years

More information

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100 1 Safety instructions Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically lead

More information

Also available with the new i-life R-Slim inverter and radiant panel version. Perfect comfort. Silent operation. Real energy savings

Also available with the new i-life R-Slim inverter and radiant panel version. Perfect comfort. Silent operation. Real energy savings The new i-life Slim fan coil, with inverter technology for heating, cooling and dehumidifying. Its elegant design with only 13 cm depth makes i-life Slim the perfect solution for residential applications.

More information

Aquamatic Instantaneous DHW production unit with integrated storage tank

Aquamatic Instantaneous DHW production unit with integrated storage tank Aquamatic Instantaneous DHW production unit with integrated storage tank The Aquamatic is an innovative plug and play system, which unites both the functions of an inertial tank and an instantaneous DHW

More information

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65% Dry HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES Calculation of savings (for illustrative purposes) Operating scheme Note: power rates refer to 10,000 m 3 /h of air and

More information

SOLAR THERMAL SYSTEM. Product catalogue

SOLAR THERMAL SYSTEM. Product catalogue SOLAR THERMAL SYSTEM Product catalogue II SUMMARY 2. INTRODUCTION 4. APPLICATIONS 6. FLAT SOLAR COLLECTORS 7. POSITIONING EXAMPLES OF THE SOLAR COLLECTORS 9. CYLINDERS AND ACCUMULATORS 9. CIRCULATION GROUPS

More information

IMI Heimeier Kit Hydroca ble

IMI Heimeier Kit Hydroca ble IMI Heimeier Kit Hydroca ble Thermostatic valves with radiator connection systems Thermostatic valve and lockshield with tube-bend for the installation as angle form or axial form with press- or sliding

More information

Installation and Operation Instructions K36E Modular Heating Circuit - DN 25 Boiler charging set

Installation and Operation Instructions K36E Modular Heating Circuit - DN 25 Boiler charging set PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 Email: info@paw.eu, Web: www.paw.eu Installation and Operation Instructions K36E Modular Heating

More information

LK Heat Exchanger Pack 10 -n

LK Heat Exchanger Pack 10 -n LK Heat Exchanger ack 10 -n 6 9 14 2 5 15 7 4 12 11 13 10 3 14 1 Design The LK Heat Exchanger ack -10 is primarily designed for glycol based under floor heating systems that must be isolated from other

More information

Adjustable three-way thermostatic mixing valve... connections ½", ¾", 1" NPT male union and sweat union and ¾" press

Adjustable three-way thermostatic mixing valve... connections ½, ¾, 1 NPT male union and sweat union and ¾ press MixCal djustable three-way thermostatic mixing valve series CCRIT ISO 9 FM ISO 9 No. CLFFI / N Replaces / N Function The Caleffi MixCal series three-way thermostatic mixing valve is used in systems producing

More information

Aquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes

Aquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes Thermostatic valve with adjustable temperature control range Technical information Tender specification: Oventrop thermostatic valve Aquastrom T plus with presetting for circulation pipes. Thermal control

More information

Installation and operating instructions. DK energy storage and DK energy buffer

Installation and operating instructions. DK energy storage and DK energy buffer Installation and operating instructions DK energy storage and DK energy buffer Edition: 08-2015 1 Preliminary note With this DK energy storage / DK energy buffer you purchased a DK quality product. The

More information

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems E-Z Valve Thermostatic valves with radiator connection systems For single and two-pipe heating systems IMI HEIMEIER / Thermostatic heads and Radiator valves / E-Z Valve E-Z Valve E-Z Valve with immersion

More information

ART-U 1-4 kw. Design fan coil unit with a minimum depth of 10 cm only and BLDC motor. Fan coil ART-U PLUS. Design-driven innovation NEW

ART-U 1-4 kw. Design fan coil unit with a minimum depth of 10 cm only and BLDC motor. Fan coil ART-U PLUS. Design-driven innovation NEW Fan coil ART-U NEW PRODUCT Design fan coil unit with a minimum depth of 10 cm only and BLDC motor ART-U 1-4 kw Available from SEPTEMBER 2018 Design-driven innovation BLDC motor Tangential fan Supervision

More information

1 Declaration of conformity

1 Declaration of conformity ENERGY SAVING 1 Declaration of conformity We Taco Italia S.r.l. declare under our sole responsibility that the family of products ENERGY SAVING to which this declaration relates are in conformity with

More information

Technical Manual. New Water Cassette. Series BREZZA DOUBLE

Technical Manual. New Water Cassette. Series BREZZA DOUBLE Technical Manual New Water Cassette Series BREZZA DOUBLE AERTESI srl Cassetta BREZZA DOUBLE Tecnical manual AER.MT.I.BREDOPPIA.000.02.15 Pag.2 INDEX 1-INTRODUCTION 4 2- WORKING CONDITION LIMITS..4 3- COANDA

More information

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher Table of Contents www.casablancafanco.com To register your fan, please visit: www.casablancafanco.com/register What to Expect with Your Installation Save your receipt for proof of purchase. Ceiling Bracket??

More information

MIX2 - MIX3 MIX2 MIX3 COMPONENTS DESCRIPTION DIMENSIONS

MIX2 - MIX3 MIX2 MIX3 COMPONENTS DESCRIPTION DIMENSIONS TCHNICAL SPCIFICATION DSCRIPTION Thermostatic mixing kit with micrometric valve with thermostatic option, circulation pump (rp Ready 641/2009/C - 622/2012/C), balancing lockshield and couple of manifolds

More information

Solar-Divicon and solar pump assembly. Please follow these safety instructions closely to prevent accidents and material losses.

Solar-Divicon and solar pump assembly. Please follow these safety instructions closely to prevent accidents and material losses. Installation and service instructions for contractors VIESMANN Solar-Divicon and solar pump assembly Safety instructions Please follow these safety instructions closely to prevent accidents and material

More information

teide termo plus+ HEATING SERIES SCOPE THERMOSTATIC VALVES SERVICE CONDITIONS COMPONENTS TECHNICAL SHEET 07/2017 IP20060 PAG. 1/9

teide termo plus+ HEATING SERIES SCOPE THERMOSTATIC VALVES SERVICE CONDITIONS COMPONENTS TECHNICAL SHEET 07/2017 IP20060 PAG. 1/9 HEATING SERIES QUALITY BY TRADITION teide termo plus+ TECHNICAL SHEET 07/2017 IP20060 SCOPE The thermostatic valves and heads from TEIDE TERMO PLUS series can be used in individual or collective heating

More information