1 Declaration of conformity

Size: px
Start display at page:

Download "1 Declaration of conformity"

Transcription

1

2 ENERGY SAVING 1 Declaration of conformity We Taco Italia S.r.l. declare under our sole responsibility that the family of products ENERGY SAVING to which this declaration relates are in conformity with the Council Directives on the approximations of the laws of the EC Member State relating to: EMCD Directive (2014/30/EU) Standard used: EN :2014, EN :2013, EN :2006, EN :1997 (including amendments) LVD Directive (2014/35/EU) Standard used: EN 62233:2008, EN :2012, EN :2003 (including amendments) ErP Directive (2009/125/EC-2012/27/EU) Commission Regulations n. 641/2009 and n. 622/2012 Applies only to circulators marked with the energy efficiency index EEI. See the pump nameplate. Standard used: EN :2012 and EN :2012 RoHS II Directive (2011/65/EU) Sandrigo, 20th April 2016 Luca Bolcati General Manager and Managing Director Person authorised to compile technical file and empowered to sign the EC declaration of Conformity. 2 Declaration of conformity

3 2 Contents 1 Declaration of conformity Contents Indication of instructions Important safety and installation instructions Field of application Types of system Pumped liquids Product information Description of the product Type key Name plate Components Supply Technical data Installation at Site Installation Permissible installation positions Motor housing regulation Insulation of pump housing Electric connection Commissioning Start-up of the circulator Operating elements Mode of operation Automatic detection of the presence of air - Vent system Circulator setting Performance curves Performance curves - ES Performance curves - ES2 ADAPT Maintenance Faults, causes and remedies Fault finding table Unlocking procedure Warranty Disposal

4 ENERGY SAVING These instructions include information necessary to assemble and use the product correctly. Besides respecting the general safety regulations, it is necessary to observe all points specifically and specially marked. 3 Indication of instructions This manual contains information and prescriptions marked by the following symbols. The inobservance of the safety provisions marked by the symbol caution: hazard may endanger the safety of people. The inobservance of the safety provisions marked by the symbol caution: electricity may endanger the safety of people, as well as the integrity of things. CAUTION The inobservance of the safety provisions marked by the word CAUTION may endanger the integrity and functionality of the equipment and of the machines. The Quick Guide contains following warning symbols. The circulators are not to be used to transfer flammable liquids such as petroleum, oils, gas oil or similar liquids. The circulators are not to be used to transfer aggressive liquids, such as acids and sea water. CAUTION The removal of the screws can cause the output of hot fluids under high pressure from heating system. Drain the system or close the isolating valves. CAUTION High temperature surface. Take utmost care to prevent people from getting in contact with the hot surfaces of the circulator. 4

5 4 Important safety and installation instructions Prior to installation, read these installation and operating instructions. The installation and operation should also be in accordance with national regulations and accepted codes of good practice. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge, only if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. To guard against injury, basic safety precautions should be observed, including the following: 1. Read and follow all safety instructions and all the important notices on the appliance before installing, using and maintaining the circulator. Failure to do so may cause personal injury or damage to the circulator or installation. 2. Always disconnect electrical supply before putting on or taking off parts and whilst the equipment is being installed, maintained or handled. Never work with bare feet and/or with wet hands. 3. To avoid possible electric shock, special care should be taken since water is used with electrical equipment. Carefully examine the circulator before and after installation. Do not operate the circulator if it has a damaged supply cord or enclosure, or if it is malfunctioning or it is dropped or damaged in any manner. Inspect the circulator periodically. The circulator should not be electrically supplied if there is water on parts not intended to be wet. 4. Risk of scalding. To avoid injury before any servicing operation wait until the water has cooled inside the circulator. Do not touch the fluid or the circulator when temperature is higher than 60 C. 5

6 ENERGY SAVING 5. Improper use This is a circulator to be used in heating systems and for the circulation of clean water without abrasive particles. This is not a submersible pump. Do not use this circulator: With liquids other than water (e.g. flammable liquids, etc.) (EN ); For handling drinkable water or food related liquids; For the circulation of domestic water; In locations where special condition prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapor or gas) (EN ); For other than intended use. Never run the circulator dry. The circulator must always be fully filled with water when operating. 6. Installation The circulator must be mounted in a stable/fixed position in a dry, well ventilated, frost-free, waterproof and protected place, with sufficient ventilation around it. Make sure that the circulator is securely and correctly installed before operating it and that there is enough room around it for maintenance operations, dismantling, checking for free inspection. The maximum ambient temperature at which the pump is to be used is 40 C (EN ). To avoid circulator overheating, do not place any object on the circulator itself. 7. Electric connection IMPORTANT: Connection to the power supply must be effected by means of a fixed power cable which is fitted with a plug-type connection or an all-pole isolating switch with a minimum contact opening of 3 mm. Electrical connection must be carried out only by a qualified electrician and in accordance with local regulations and both data on the name-plate and the appropriate diagram inside the terminal box cover. Follow all safety standards. Do not connect to mains supply unless circulator is fully and correctly assembled. 8. Supply cord must be selected following the requirements of EN Chapter 25. Supply cord must be protected against any kind of mechanical damage (cuts, abrasion, etc.). It must not touch the pipe or the pump. (EN ). If the insulation of the Supply cord can come in contact with parts having a temperature exceeding 70 C the supply cord insulation must be protected, for example, by insulating sleeving having an appropriate temperature rating. (EN ). 9. Connect circulators only to a mains supply protected by a Residual Current Device (RCD or Ground-Fault Circuit-Interrupter) with a rated residual operating current not exceeding 30mA. 10. Prior to any modification being made to the equipment, it must be agreed with and authorised by the manufacturer. Original spare parts and accessories authorised by the manufacturer are integral part contributing to the safety of the equipment and of the machines. The use of non original components or accessories may endanger the safety and causes the termination of the 6 Important safety and installation instructions

7 warranty. Safe operation is only assured for the applications and conditions described in 5 Field of application of this manual. Non-observance of the safety instructions results in the loss of any claims to damages. The indicated limit values are binding and cannot be exceeded for any reason whatsoever. KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE. 7

8 ENERGY SAVING 5 Field of application 5.1 Types of system Models ES2 ES2 ADAPT Uses Circulation of water/liquids in hot water heating systems for all kinds and in similar systems: One-pipe systems Two-pipe systems Systems with constant or variable flows Underfloor heating systems Boiler or primary circuit Storage tank circuit Circulation of water/liquids in hot water heating systems and in renewable energy solar thermal systems: Solar thermal systems One-pipe systems Two-pipe systems Systems with constant or variable flows Underfloor heating systems Boiler or primary circuit Storage tank circuit 5.2 Pumped liquids For use with clean liquids, that are not aggressive or explosive and not containing solid particles, fibres or mineral oils. In heating systems: Water for heating according to VDI Mixtures of water and glycol with glycol percentages not greater than 30%. In domestic hot water circulation systems, max. 38 d water hardness. Any other use is regarded as incorrect use. For the use with other fluids, manufacturer s authorisation is required. The circulators are not to be used to transfer flammable liquids such as gasoline, oils, gas oil or similar liquids. The circulators must never be used in refrigeration systems, air conditioning systems and similar installations. 8 Field of application

9 6 Product information 6.1 Description of the product The ENERGY SAVING are a range of innovative wet rotor circulators with an integrated frequency converter (INVERTER). ENERGY SAVING circulators combine an advanced hydraulic system, a high efficiency motor, an intuitive electronic control and an operating software that allows the pump to perfectly adapt to the various operating conditions and the actual needs of the system. The motor with electronic control module is mounted on the pump housing by four screws. The criteria for differential pressure control depend on the set operating mode. In all operating modes, the circulator adapts to the different loads of the system. ENERGY SAVING provides excellent benefits: 1. Energy saving 2. Compact design 3. Ideal performance 4. Easy installation and adjustment The ENERGY SAVING circulator range is available in the following versions: ES2 ES2 ADAPT Standard version with operating modes P, C and min-max. Pump housing available in cast iron, plastic composite material (C) and plastic composite material with air separator (C A) Premium version with operating modes activeadapt, P, C and min-max. Pump housing available in cast iron. 6.2 Type key 9

10 ENERGY SAVING 6.3 Name plate 1 Type 2 Code 3 Input power P1[W] / Input curren I1[A] / System pressure [MPa] 4 Voltage, frequency 5 Temperature class / Protection class 6 Energy Efficiency Index (EEI) Fig. 6.1: Name plate (example) 7 CE mark / Appliance class / Quality mark 6.4 Components Fig. 6.2: Exploded view A Pump housing E Stator B Impeller and bearing plate F Electronics C Rotor G Motor housing D Can H Front cover 6.5 Supply Complete circulator. Two flat seals in EPDM. Thermal insulation shells in EPP (supplied as standard only for mod. ES2 ADAPT) Instructions for assembly, use and maintenance. 10 Product information

11 6.6 Technical data Power supply 1x230 V ±10%, 50 Hz Adjustment of the rotation speed Manual by selector Motor protection Not required Insulation class H Protection class IP 44 Appliance class II Ambient temperature from +2 C to +40 C Allowed liquid temperature ES2 from +2 C to +95 C ES2 ADAPT from +2 C to +110 C Maximum relative humidity 95% Maximum operating pressure ES2 0,6 MPa (6 bar) ES2 ADAPT 1,0 MPa (10 bar) Minimum pressure Liquid temperature Minimum pressure on the intake opening MPa (0.3 bar) 50 C 0.10 MPa (1.0 bar) 95 C 0.15 MPa (1.5 bar) 110 C Sound pressure level < 43 db(a) EMC (electromagnetic compatibility) EN / EN EN / EN Specific EEI values 2 ES2 60 ES2 ADAPT 60 EEI 0,20 - Part 2 To avoid condensation in the motor and the electronics the temperature of the pumped liquid must always be greater than the ambient temperature. ES2 ES2 ADAPT Ambient temperature Liquid temperature [ C] Min. [ C] Max. [ C] To avoid cavitation noise, minimum pressure values on the intake opening must be strictly respected. 2 The benchmark for most efficient circulators is EEI 0,20. 11

12 ENERGY SAVING 7 Installation at Site Installation and service by qualified personnel only! 7.1 Installation The circulator must be mounted in a stable/fixed position in a dry, well ventilated, frost-free, waterproof and protected place, with sufficient ventilation around it. Assemble the circulator only after having ended all welding and brazing works on the hosing. Before installing the circulator, make sure that the internal part of the tubes is clean. Install the circulator in an accessible place for future checks and disassembly procedures. Foresee enough space for inspections and disassembling. Foresee isolating valves at intake and output (before and after the circulator) to allow the disassembly without emptying the plant. The assembly of the interception organs must be carried out in such a way as to prevent possible water leaks from involving the terminal board. Perform the assembly without mechanical stresses acting on the circulator. Avoid the installation in misaligned pipe work. Fig. 7.1: Mounting procedure. The direction of the water flow is indicated by the arrow on the pump housing, as shown in Fig Check that both isolating valves are closed. 2. Install the circulator with the motor shaft in horizontal position. Connect the piping without transmitting any stresses and strains. 3. Accurately insert the two gaskets supplied. 4. Establish a screwed connection between circulator and piping. 5. Tighten the screwed connection hand with an assembly tool (e.g. pipe wrench). 12 Installation at Site

13 Thread Pump housing material Tightening torque G1 Composite PA 66 GF Max. 50 Nm G1 Cast Iron EN-GJL-200 Max. 85 Nm G1½ Cast Iron EN-GJL-200 Max. 125 Nm G2 Cast Iron EN-GJL-200 Max. 165 Nm 7.2 Permissible installation positions Install the circulator with horizontal motor shaft axis (Fig. 7.2). Fig. 7.2: Permissible installation positions 7.3 Motor housing regulation Fig. 7.3: Motor housing positions The motor body can be rotated in the positions shown in Fig Take utmost care to prevent people from getting in contact with the hot surfaces of the circulator. Drain the system or close the isolating valves on either side of the pump before the screws are removed. The pumped liquid may be scalding hot and under high pressure. CAUTION Pay attention not to damage the seal of the pump housing. 13

14 ENERGY SAVING Fig. 7.4: Changing the motor body position Procedure (Fig. 7.4): 1. Slacken and remove the four screws M5 holding the motor. 2. Turn the motor to the desired position without extracting it from the pump housing. 3. Insert and tighten the pump housing screws (The tightening torque of the screws of the pump housing must correspond to a value of 3.3 ± 0.5 Nm). 7.4 Insulation of pump housing Fig. 7.5: Insulation of pump housing The heat loss from the pump and pipework can be reduced by insulating the pump housing and the pipe with the thermal insulation shells supplied with the circulator (supplied as standard only with model ES2 ADAPT) Fig The thermal insulation shells can be ordered separately. CAUTION Do not insulate the control box or cover the control panel. 14 Installation at Site

15 8 Electric connection The electric connection has to be performed by a qualified electrician in compliance with the national regulations. Follow the safety regulations and installation regulations of your country. Connection to the power supply must be carried out in compliance with the standards via a fixed power cable which is fitted with a plug-type connection or an all-pole isolating switch with a minimum contact opening of 3 mm. The circulator belongs to class II and therefore grounding is not necessary. The circulator does not require any external protection of the motor. Compare the frequency and the voltage of the mains with the rating data. All electric information concerning the circulator is on the signaling plate. The connection cord must be laid in such a way as it cannot come in contact with the hosing or the motor body. In case of use of the circulator with fluids at a temperature higher than 70 C, use a connection cord resistant to high temperatures. 1x230 V (±10%), 50 Hz Fig. 8.1: Electric connection 1. Connect the power supply conductors to the terminals according to the diagram given in Fig. 8.1, from A to C. 2. Insert the terminal board in the proper seat, connecting the blue wire (neutral) with letter N and the black/brown wire (phase) with letter L. (Fig. 8.1.D). 3. Screw the two screws (Fig. 8.1.E - The tightening torque of the screws must correspond to a maximum value of 0,3 Nm). 4. Tighten the sealing nuts to the fairlead (Fig. 8.1.F - The tightening torque must correspond to a maximum value of 2 Nm). 5. The LED light, if lighted, indicates that the power supply is present. (Fig. 8.1.G). To ensure drip protection and strain relief at the PG screwed connection, a connected load with an adequate outer diameter is necessary (e.g. H05VV-F 2x1, H05RN-F 2x1, H05VV-F 3x1 o H05RN- F 3x0,75). 15

16 ENERGY SAVING 9 Commissioning 9.1 Start-up of the circulator CAUTION CAUTION CAUTION You must avoid dry operation. Start the circulator only after having completely filled the plant. Circulators with permanent magnets can not be driven in speed by means of phase control of the supply voltage. Circulators driven by an electronic frequency converter have a current peak at each activation (inrush current) greater than traditional circulators (asynchronous). The activation stage of the circulator has to be size taking into account this current peak. For further details contact the manufacturer. Activation frequency: activations/deactivations through the mains voltage 20/24 h. 9.2 Operating elements Selector All settings are made using the selector on the housing front. The selector can be adjusted in a continuous way with a rotation angle of 270. The arrow on the selector indicates the operating mode chosen. LED light The LED light on the front advises the commissioning/fault of the circulator. Every operating mode is characterised by a fixed light of different colour. After a change of operating mode, the LED pulses 5 times. The pulse will be a change of brightness intensity of the LED light. Fig. 9.1: Selector and LED light 16 Commissioning

17 9.3 Mode of operation An LED provides information about the operation status of the circulator. LED COLOR DESCRIPTION Violet activeadapt mode The activeadapt mode enables the circulator to actively adapt its performance to the demands of the system during short control intervals inside a defined control area. Improves the hydraulic balance of the system Ensures optimum performance during partial load periods Enables quick installation Green P mode ( p-v) Proportional differential pressure The circulator head is proportionally reduced at falling water demand and increased at rising water demand. The circulator head is proportionally reduced with decreasing of the heat demand from the heating system (flow rate decrease) and is proportionally increased with increasing demand of the heat demand from the heating system (flow rate increase). Orange Blue C mode ( p-c) - Constant differential pressure The circulator maintains a constant pressure level (head) irrespectively of the heat demand required from the heating system (flow rate). min-max mode Fixed speed The circulator maintains a fixed speed irrespective of the heat demand from the heating system (flow rate). The speed regulation is done by positioning the selector in a gradual manner at any point between the Min and Max positions. Should this performance be insufficient, progressively increase the set value. Should this performance be excessive or should noise arise due to the speed of the pumped fluid, progressively reduce the calibration. Flashing white Red Automatic detection of the presence of air. Proceed with the vent routine Fault or malfunction 13 Faults, causes and remedies 17

18 ENERGY SAVING 9.4 Automatic detection of the presence of air - Vent system. Fig. 9.2: Filling and venting of heating systems Fill and bleed the system correctly. The circulator can be noisy at start due to the presence of air. Such noise should stop after few minutes of operation. The pump rotor chamber normally bleeds automatically after a short time in operation. The circulator is equipped with a special software system that detects the presence of excess air within the heating system. The LED shows the presence of air in the hydraulic circuit by flashing and performing a rapid succession of WHITE colour. Following the light signal, it s possible to easily vent the heating system as follows: 1. Open the air vent valve in the hydraulic circuit above the circulator; 2. set the circulator to MAX position (maximum performance setting); 3. let the circulator run for a short period, according to the construction and the plant size; 4. once vented the system - the guide light (LED) stops blinking and the possible noise stops - set the circulator as indicated in Par.10 Circulator setting Repeat the procedure if necessary. CAUTION The system cannot be drained by using the circulator. With solar thermal systems, fill the system with mixtures prepared for that application. The circulator cannot be used to mix the fluids in the system. Do not touch the fluid or the circulator when the temperature is greater than 60 C. Hazard of scalding by simple contact. 18 Commissioning

19 10 Circulator setting Modify the performance of the circulator (head) as needed by rotating the selector using a flat screwdriver, as given in the following table. The selection of the right functioning curve depends on the characteristics of the heating system in question and the actual heat demand. LED ES2 ADAPT MODEL ES2 - activeadapt * Lowest proportional curve P1 Lowest proportional curve P1 * Intermediate proportional curve P2 Highest proportional curve P2 - Highest proportional curve P3 Lowest constant curve CI Lowest constant curve CI Intermediate constant curve CII Highest constant curve CII - Highest constant curve CIII Fixed speed curves min - max Fixed speed curves min - max * Factory setting 19

20 ENERGY SAVING 11 Performance curves 11.1 Performance curves - ES Performance curves - ES2 ADAPT Performance curves

21 12 Maintenance The circulator does not require any special maintenance during operation. Motor bearings are lubricated by the pumped liquid. Before each maintenance intervention, disconnect power supply and wait for the circulator to cool. 13 Faults, causes and remedies 13.1 Fault finding table FAULTS CONTROL PANEL CAUSES REMEDIES The circulator is noisy Loud noises of water circulation LED on LED on Flashing white LED LED on Suction pressure is insufficient - cavitation Presence of foreign bodies in the impeller Air in the system The flow is too high Lack of power supply One fuse in the installation is blown Increase the system suction pressure within the permissible range. Disassemble the motor and clean the impeller Vent the system ( 9.4 Automatic detection of the presence of air - Vent system.) Reduce the rotation speed ( 10 Circulator setting) Verify voltage value of the electric plant Verify the connection of the motor Verify the fuses of the plant LED off The circulator is defective Replace the pump. Circulator is not running although the electrical power supply is switched on LED red Overheating The rotor is blocked Let the pump cool down for some minutes. Then try to re-start it. Verify that the water and ambient temperature are within the indicated temperature ranges. Disassemble the motor and clean the impeller. Should you fail to eliminate the cause of the malfunction, refer to the Distributor or nearest Service Centre. If this doesn't succeed ( 13.2) Insufficient supply voltage Verify that the power supply matches the data on the name plate. Building does not get warm. LED on The circulator performance is too low Increase the suction head ( 10 Circulator setting) 21

22 ENERGY SAVING Should you fail to eliminate the cause of the malfunction, refer to the Distributor or nearest Service Center Unlocking procedure A red light in the LED indicates a locking. Turn the selector to the position max, disconnect and connect power supply to start the automatic release process. The circulator operates 100 attempts to restart (process lasts approximately 15 minutes). Every restart is signalled by a short flash of LED light. If the locking is not removed through the automatic release process after 100 attempts to restart the circulator, it goes into standby and the LED remains red. In this case follow the manual procedure described in the next steps: during any attempt, the red LED light keeps blinking; after that the circulator tries again to start. If the locking is not removed through the automatic release process (the warning light returns to be red), it is necessary to perform the manual procedure described in the next steps: Disconnect power supply - the warning light switches off. Close the interception organs upstream and downstream of the circulator and let it cool. Disassemble the motor and clean the impeller. 1. Disconnect power supply - the warning light switches off. 2. Close both isolating valves and allow cooling. If there are no shut-off devices, drain the system so that the fluid level is beneath that of the circulator. 3. Carefully pull the rotor/impeller 4. Remove impurities and deposits with appropriate agents. 5. Reinsert the rotor/impeller 6. Set the selector on the wished position. 7. Connect power supply. If the circulator doesn t run 13 Faults, causes and remedies. With high fluid temperatures and pressures there is the risk of burning. Hazard of scalding by simple contact. 14 Warranty The Smith's 5 year warranty covers manufacturing or material defects on domestic heating circulators. It does not cover installation or system design faults, damaged packaging or pumps seized due to system deposits. Proof of purchase required for administrating warranty claims. 15 Disposal The correct disposal and recycling of this product will prevent damage to the environment and risks to human health. 1. Use public or private disposal organisations when disposing of all or part of the product. 2. For information about proper disposal, it is necessary to ask to the city administration, the authorised office or the retailers of the product. Reserved right of modification 22 Warranty

23

Space Saver. Installation and user manual SS3 SS5 SS7 SS9. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk

Space Saver. Installation and user manual SS3 SS5 SS7 SS9. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk Space Saver Installation and user manual SS3 SS5 SS7 SS9 Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk Contents Introduction 2 Declaration of conformity 3 Symbols used in this guide 3 Important

More information

HIGH EFFICIENCY CIRCULATORS. Represented by Taconova Group AG CATALOGUE 2018 EN. easyuse. greatperformance

HIGH EFFICIENCY CIRCULATORS. Represented by Taconova Group AG CATALOGUE 2018 EN. easyuse. greatperformance HIGH EFFICIENCY CIRCULATORS Represented by Taconova Group AG CATALOGUE 218 EN easyuse greatperformance CONTENTS WELCOME...3 HEATING SYSTEMS ES2 6...4 ES2 7...6 ES2 C A 6...8 ES2 ADAPT 6...1 ES2 ADAPT 7...12

More information

COMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS

COMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS COMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS INSTALLATION AND OPERATING INSTRUCTIONS File No: 10.895 Date: march 8, 014 Supersedes: 10.895 Date: december 10, 013 1.0 Symbols used in this document 1.0

More information

HIGH EFFICIENCY CIRCULATORS

HIGH EFFICIENCY CIRCULATORS HIGH EFFICIENCY CIRCULATORS Heating, Cooling, Solar Thermal and Domestic Hot Water SAVINGS Up to 80% less than traditional pumps TECHNOLOGY Best available technology - PM Motor ENVIRONMENT Environment

More information

Pedestal Range. Installation and user manual. Kiosk. Trafalgar. Tube. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk

Pedestal Range. Installation and user manual. Kiosk. Trafalgar. Tube. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk Pedestal Range Installation and user manual Kiosk Trafalgar Tube Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk Contents Introduction 2 Declaration of conformity 3 Symbols used in this guide 3

More information

GRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz

GRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz GRUNDFOS DATA BOOKLET UPS2 Circulator pumps 50/60 Hz UPS2 Table of contents 1. Product introduction 3 Type key.................................................................................... 3 Performance

More information

CRU-S Series Stainless Steel Condensate Recovery Unit

CRU-S Series Stainless Steel Condensate Recovery Unit IM-UK-CRU-S UK Issue 1 CRU-S Series Stainless Steel Condensate Recovery Unit 1. Safety information 2. General product information 3. Installation 4. Commissioning 5. Storage, shutdown and equipment protection

More information

Space Saver. Installation and user manual. Issue 001 March 2018 ENGLISH UK IRL SmithsEP.co.uk. Issue March 2018 smithsep.co.

Space Saver. Installation and user manual. Issue 001 March 2018 ENGLISH UK IRL SmithsEP.co.uk. Issue March 2018 smithsep.co. Space Saver Installation and user manual SS2E / 5 Issue 001 March 2018 ENGLISH UK IRL SmithsEP.co.uk Issue 001 - March 2018 smithsep.co.uk 1 Contents Introduction 2 Declaration of conformity 2 Symbols

More information

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes 50-120 1 General The heat exchanger control system is a control system for 380 W step motors

More information

USE AND INSTALLATION HANDBOOK

USE AND INSTALLATION HANDBOOK Date : 30/10/14 Rev. 02 PR.T : FG006203 USE AND INSTALLATION HANDBOOK (SLA1) ALARM1, ALARM2 ALARM WITH BUFFER BATTERY Via Enrico Fermi, 8-35020 Polverara PD Tel.049/9772407 Fax.049/9772289 www.fourgroup.it

More information

User Manual. Electric Heating Element MEG DRY MOA REG 2 REG 3

User Manual. Electric Heating Element MEG DRY MOA REG 2 REG 3 User Manual Electric Heating Element MEG DRY MOA REG 2 REG 3 User Manual Our products have been designed and manufactured in such a way to ensure that all quality, functionality and aesthetic requirements

More information

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59 SOUND-INSULATED FAN OPERATION MANUAL _v.1(2)-en.indd 1 10.08.2015 15:20:59 CONTENT Introduction 3 General 3 Safety rules 3 Transport and storage requirements 3 Manufacturer's warranty 3 Fan design 4 Delivery

More information

Operating instructions

Operating instructions ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 (0) 793-0 Fax +49 (0) 793-0 info@de.ebmpapst.com www.ebmpapst.com CONTENTS. SAFETY REGULATIONS AND NOTES. Levels of hazard warnings.

More information

LS Condensate Removal Pump INSTRUCTION MANUAL REVISION A

LS Condensate Removal Pump INSTRUCTION MANUAL REVISION A LS Condensate Removal Pump INSTRUCTION MANUAL 6-71-075-115 REVISION A CAUTION: Combustible liquids may not be pumped! The condensate pump may not be run dry, as this can destroy the bearings in a very

More information

Sargasso Range. Installation manual. Sargasso A. Issue 001 January 2018 ENGLISH UK IRL SmithsEP.co.uk

Sargasso Range. Installation manual. Sargasso A. Issue 001 January 2018 ENGLISH UK IRL SmithsEP.co.uk Sargasso Range Installation manual Sargasso A Issue 001 January 2018 ENGLISH UK IRL SmithsEP.co.uk Contents Introduction 2 Symbols used in this guide 2 Declaration of conformity 2 Important safety and

More information

VERSAFLOW VORTEX Supplementary instructions

VERSAFLOW VORTEX Supplementary instructions VERSAFLOW VORTEX Supplementary instructions Vortex flowmeter Equipment category II 2G CONTENTS VERSAFLOW VORTEX 1 Safety instructions 3 1.1 General notes... 3 1.2 EC conformity... 3 1.3 Approval according

More information

INSTALLATION, COMMISSIONING AND OPERATING MANUAL

INSTALLATION, COMMISSIONING AND OPERATING MANUAL INSTALLATION, COMMISSIONING AND OPERATING MANUAL 1 YTBV-D-CE42_0109 CONTENT Available models and capacities Supplier information Warranty Safety Emergency stops/ shutdowns About this manual Models Physical

More information

Sargasso Range. Installation manual. Sargasso S. Issue 001 January 2018 ENGLISH UK IRL SmithsEP.co.uk

Sargasso Range. Installation manual. Sargasso S. Issue 001 January 2018 ENGLISH UK IRL SmithsEP.co.uk Sargasso Range Installation manual Sargasso S Issue 001 January 2018 ENGLISH UK IRL SmithsEP.co.uk Contents Introduction 2 Symbols used in this guide 2 Declaration of conformity 2 Important safety and

More information

GRUNDFOS DATA BOOKLET. Grundfos COMFORT. Circulator pumps. 50/60 Hz

GRUNDFOS DATA BOOKLET. Grundfos COMFORT. Circulator pumps. 50/60 Hz GRUNDFOS DATA BOOKLET Circulator pumps 50/60 Hz 2 Product range 2. Product range UP(S) COMFORT, 50/60 Hz Pump type 24-hour timer Supplied with Dimensions Accessories Data sheet Thermostat Isolating valve

More information

DIRTY WATER SUBMERSIBLE PUMP

DIRTY WATER SUBMERSIBLE PUMP WHAT S IN THE BOX DIRTY WATER SUBMERSIBLE PUMP 780W INSTRUCTION MANUAL SPECIFICATIONS Motor: 780W Max. Flow Rate: 15,700l/h Max. Head 8m Max. Immersion: 7m Min. Suction Depth 50mm Max Particle Size: Ø35mm

More information

DIRTY WATER SUBMERSIBLE PUMP KIT

DIRTY WATER SUBMERSIBLE PUMP KIT WHAT S IN THE BOX DIRTY WATER SUBMERSIBLE PUMP KIT 1000W INSTRUCTION MANUAL SPECIFICATIONS Motor: 1000W Max. Flow Rate: 18,000l/h Max. Head 9m Max. Immersion: 7m Min. Suction Depth 50mm Max Particle Size:

More information

Flo~mate Mains Boost Pump Installation & Maintenance Instructions

Flo~mate Mains Boost Pump Installation & Maintenance Instructions ~ Flo~mate Mains Boost Pump Installation & Maintenance Instructions Please leave this instruction booklet with the owner as it contains important guarantee, maintenance and safety information FOR POSITIVE

More information

VADA - Rain2Main Automatic Rainwater Controller

VADA - Rain2Main Automatic Rainwater Controller PRODUCT OVERVIEW / APPLICATION The Vada Rain2Main is designed to select between stored rainwater (when available) and mains supply water, and send this water to your toilet cistern, washing machine, garden

More information

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP WWPPCHLFT260 Instructions WWPPCHLFT260_Horizontal Multistage Centrifugal Pump_IB.indd 1 READ THIS MANUAL CAREFULL BEFORE INSTALL, START THE PUMP 1. Suction 2. Plug

More information

GRUNDFOS INSTRUCTIONS MAGNA1. Installation and operating instructions

GRUNDFOS INSTRUCTIONS MAGNA1. Installation and operating instructions GRUNDFOS INSTRUCTIONS MAGNA1 Installation and operating instructions English (US) English (US) Installation and operating instructions Original installation and operating instructions. CONTENTS Page 1.

More information

10 & 12 Ventilator. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

10 & 12 Ventilator. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN TTV 1500 / TTV 3000 EN OPERATING MANUAL CONVEYING FAN TRT-BA-TTV1500-3000-TC2016-26-004-EN Table of contents Notes regarding the operating manual... 2 You can download the current version of the operating

More information

OPERATION AND MONTAGE MANUAL ROOF FANS

OPERATION AND MONTAGE MANUAL ROOF FANS NO RFEC/U/2017-1 (EN) (valid since 18.08.2017) ROOF FANS RF/EC...-... / RFV/EC...-... Venture Industries Sp. z o.o. is not responsible for any damage caused by improper use of the fan and reserves the

More information

CENTRIFUGAL PUMPS OPERATING INSTRUCTIONS

CENTRIFUGAL PUMPS OPERATING INSTRUCTIONS CENTRIFUGAL PUMPS OPERATING INSTRUCTIONS Please leave this instruction booklet with the pump as it contains maintenance and safety information (Original Instructions) MODELS This operating manual covers

More information

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - US10 EPU - US15

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - US10 EPU - US15 INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - US10 EPU - US15 01 CONTENTS Special information 2 General information 3 Safety 5 Appliance description, cleaning, care & maintenance 7 Appliance

More information

Hot Water Circulator Pump LRP

Hot Water Circulator Pump LRP Hot Water Circulator Pump LRP Contents. Introduction.... Safety Instruction... 3.Product Structure... 4 4. Technical Parameters... 7 5. Precautions... 8 9. Troubleshooting Disconnect power supply before

More information

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i. Additional Operating Instructions SITRANS F Vortex flowmeters Ex-i Edition 09/2018 CONTENTS 1 Safety instructions 3 1.1 General notes... 3 1.2 EU conformity... 3 1.3 Approval according to the IECEx scheme...

More information

24 & 30 Drum Fan. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

24 & 30 Drum Fan. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI500EN 09/2017

More information

LS Condensate Removal Pump Installation, Operation and Service Instructions

LS Condensate Removal Pump Installation, Operation and Service Instructions Bell & Gossett Instruction Manual 6-71-075-115 LS Condensate Removal Pump Installation, Operation and Service Instructions INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER S USE. WARNING: This safety

More information

UP/UPS-B/UPN Hot Water Service Circulators

UP/UPS-B/UPN Hot Water Service Circulators UP/UPS-B/UPN Hot Water Service Circulators Visions & Values It is the Vision of the Company to achieve our Corporate Mission by providing quality and innovative products and services that give our customers

More information

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN TTK 75 ECO EN OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN Table of contents Notes regarding the operating manual... 01 Information about the device... 02 Safety... 04 Transport...05 Start-up...05

More information

1592P01. for liquids in piping DN

1592P01. for liquids in piping DN 1 594 1592P01 Flow switch for liquids in piping DN 20 200. QVE1901 Contact load / switching capacity: max. AC 230 V, 1 A, 26 VA max. DC 48 V, 1 A, 20 W Nominal pressure PN25 Manual setting of contact type

More information

AHW AHW(S) Hot water circulator pump INSTALLATION AND OPERATING INSTRUCTIONS HIGH-EFFICIENCY BLDC-MOTOR CIRCULATORS

AHW AHW(S) Hot water circulator pump INSTALLATION AND OPERATING INSTRUCTIONS HIGH-EFFICIENCY BLDC-MOTOR CIRCULATORS AHW AHW(S) Hot water circulator pump INSTALLATION AND OPERATING INSTRUCTIONS HIGH-EFFICIENCY BLDC-MOTOR CIRCULATORS EC Declaration of Conformity Declare that machinery described: AHW,AHW(S) Hot water circulator

More information

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use! Mess-, Regel- und Überwachungsgeräte für Haustechnik, Industrie und Umweltschutz Lindenstraße 20 74363 Güglingen Telefon +49 7135-102-0 Service +49 7135-102-211 Telefax +49 7135-102-147 info@afriso.de

More information

Astro 2 circulator models. Installation and operating instructions

Astro 2 circulator models. Installation and operating instructions Astro 2 circulator models Installation and File No: 10.89 Date: august 05, 2013 Supersedes: 10.89 Date: june 26, 2013 contents 1.0 Introduction 4 2.0 Installing 4 2.1 Terminal box 4 2.2 Electrical wiring

More information

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50 -30 Installer manual Air/air heat pump -40/50 IHB GB 1516-1 331554 Table of Contents 1 Important information 2 5 Installation 7 Safety information 2 Model combinations 7 Read before starting the installation

More information

V80-H Multistage Pump Instruction Manual

V80-H Multistage Pump Instruction Manual V80-H Multistage Pump Instruction Manual PRODUCT OVERVIEW The VADA horizontal multistage centrifugal pumps combine the functional benefits of centrifugal pumps and the practical benefits of self priming

More information

CRU 200 and 500 Series Condensate Recovery Unit Installation and Maintenance Instructions

CRU 200 and 500 Series Condensate Recovery Unit Installation and Maintenance Instructions 6810850/1 IM-P681-07 ST Issue 1 CRU 200 and 500 Series Condensate Recovery Unit Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning

More information

Hozelock Ltd. Midpoint Park, Birmingham B76 1AB. England Tel: +44 (0)

Hozelock Ltd. Midpoint Park, Birmingham B76 1AB. England Tel: +44 (0) 7825 flood PUMP Hozelock Ltd. Midpoint Park, Birmingham B76 1AB. England Tel: +44 (0) 121 313 1122 info@hozelock.com www.hozelock.com 33713-001? 1 AUTO ON AUTO OFF 400mm 190mm 2 3 25mm 32mm 4 5 50cm 50cm

More information

IMPORTANT SAFEGUARDS Danger! Danger of burns!! Important!

IMPORTANT SAFEGUARDS Danger! Danger of burns!! Important! IMPORTANT SAFEGUARDS When using any electrical appliance, some basic safety precautions should always be observed to reduce the risk of fire, electric shock, and/or injury to persons. Read all instructions

More information

SAFETY AND OPERATING MANUAL

SAFETY AND OPERATING MANUAL SAFETY AND OPERATING MANUAL Original instructions 2 General Safety Warnings WARNING! Read all safety warnings and all instructions. Failure to follow the warnings and instructions may result in electric

More information

User and maintenance manual

User and maintenance manual GB User and maintenance manual IMPORTANT SAFETY INSTRUCTIONS These instructions shall also be available on website: docs.whirlpool.eu. YOUR SAFETY AND THAT OF OTHERS IS HIGHLY IMPORTANT. This manual and

More information

40E ELECTRIC FAN HEATER

40E ELECTRIC FAN HEATER 40E ELECTRIC FAN HEATER PRODUCT MANUAL IMPORTANT READ AND UNDERSTAND THIS MANUAL BEFORE ASSEM- BLING, STARTING OR SERVICING THE HEATER. IMPROPER USE OF HEATER CAN CAUSE SERIOUS INJURY. KEEP THIS MANUAL

More information

TH100 Three in One Instant Hot Water Tap

TH100 Three in One Instant Hot Water Tap TH100 Three in One Instant Hot Water Tap Installation, Use and Maintenance Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer.care@cda.eu

More information

ONE. User Manual. Electric Heating Element

ONE. User Manual. Electric Heating Element ONE User Manual Electric Heating Element Electric radiator & Electric Heating Element General rules. 1. Electric heater is not a toy. Children under the age of 3 should not be allowed within close proximity

More information

HR 601 C A AUS. ENGLISH Instructions for use Page 2

HR 601 C A AUS. ENGLISH Instructions for use Page 2 HR 61 C A AUS ENGLISH Instructions for use Page 2 1 INSTRUCTION FOR USE IMPORTANT SAFETY INSTRUCTIONS BEFORE USING THE GLASS CERAMIC HOB INSTALLATION ELECTRICAL CONNECTIONS ENERGY SAVING TIPS SAFEGUARDING

More information

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A... 70 80 99-00-O Residential Gas Condensing Boiler ZBR//8/35/4-3A... ZWB8/35/4-3A... 70 80 993 (03/03) CA/US Operating Instructions Contents Contents Key to symbols and safety instructions............................

More information

3. To protect against electric shock, do not immerse cord, plugs, or machine in water or other liquid.

3. To protect against electric shock, do not immerse cord, plugs, or machine in water or other liquid. 1 IMPORTANT SAFEGUARDS When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and/or injury to persons, including the following:

More information

CPE RANGE PUMPS CPE RANGE PUMPS. MODEL Nos: CPE15A1 15A3 20A1 20A3 30A1 30A3 PART Nos:

CPE RANGE PUMPS CPE RANGE PUMPS. MODEL Nos: CPE15A1 15A3 20A1 20A3 30A1 30A3 PART Nos: CPE RANGE PUMPS CPE RANGE PUMPS MODEL Nos: CPE15A1 15A3 20A1 20A3 30A1 30A3 PART Nos: 7120305 7120310 7120315 7120320 7120325 7120330 OPERATION & MAINTENANCE INSTRUCTIONS GC0514 Contents Specifications...

More information

CP-200 Push Button. CP Warewash Pump Instruction & Operation Manual Push Button , Rev1.0,

CP-200 Push Button. CP Warewash Pump Instruction & Operation Manual Push Button , Rev1.0, CP-200 - Warewash Pump Instruction & Operation Manual Push Button 20-08881-01, Rev1.0, 25.06.2012, Page 1 of 8 Contents A) Description B) Site Survey and Installation Requirements C) Package Contents D)

More information

51AKS I S O OWNER S MANUAL

51AKS I S O OWNER S MANUAL LLOYD'S REGISTER QUALITY ASSURANCE 51AKS I S O 9 00 1 OWNER S MANUAL This manual applies to the following models Stand-alone Split 51AKS 085--- 51AKS 010--- 51AKS 185--- 51AKS 013--- 51AKS 113--- 51AKS

More information

TTV 4500 / TTV 4500 HP / TTV 7000

TTV 4500 / TTV 4500 HP / TTV 7000 TTV 4500 / TTV 4500 HP / TTV 7000 EN OPERATING MANUAL AXIAL FAN TRT-BA-TTV4500-4500HP-7000-TC-003-EN Table of contents The current version of the operating manual can be found at: Notes regarding the operating

More information

AXIAL FAN User s manual. Quiet-dMEV 100 DC.

AXIAL FAN User s manual. Quiet-dMEV 100 DC. AXIAL FAN User s manual Quiet-dMEV 100 DC www.ventilation-system.com CONTENTS Delivery set... 6 Brief description... 6 Operating guidelines... 6 Designation key... 7 Installation and set-up... 7 Fan options...

More information

Installation & Operating Instructions. Models: York Midi & Serrano Electric Stoves

Installation & Operating Instructions. Models: York Midi & Serrano Electric Stoves Installation & Operating Instructions Models: York Midi & Serrano Electric Stoves PLEASE NOTE THAT THIS APPLIANCE USES A MOTOR TO OPERATE THE FLAME EFFECT AND THAT IT MAY BE POSSIBLE TO HEAR IT WHERE THE

More information

Inverted Bucket Steam Traps

Inverted Bucket Steam Traps INSTALLATION AND MAINTENANCE INSTRUCTIONS IM-2-00-US December 201 Inverted Bucket Steam Traps Safety Information Safe operation of these products can only be guaranteed if they are properly installed,

More information

FW422. Integrated In Column Larder Fridge. Installation, use and maintenance.

FW422. Integrated In Column Larder Fridge. Installation, use and maintenance. FW422 Integrated In Column Larder Fridge Installation, use and maintenance www.cda.eu Contents: 3 Important information 5 Important safety warnings 6 Before first use 7 Setting the temperature 7 Guidance

More information

HEAT RECOVERY AIR HANDLING UNIT

HEAT RECOVERY AIR HANDLING UNIT HEAT RECOVERY AIR HANDLING UNIT OPERATION MANUAL KOMFORT_L v2(2)_en.indd 1 07.08.2015 15:0:44 CONTENTS Introduction General Safety regulations Transportation and storage regulations Manufacturer's warranty

More information

VIESMANN. Installation instructions. Mixer extension kit. for contractors. Mixer extension kit. For one heating circuit with mixer

VIESMANN. Installation instructions. Mixer extension kit. for contractors. Mixer extension kit. For one heating circuit with mixer Installation instructions for contractors VIESMANN Mixer extension kit For one heating circuit with mixer Mixer extension kit 5/2017 Safety instructions Please follow these safety instructions closely

More information

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

User Manual GV25 GV35 GV702. Company information:   Original instructions GV12066 (1) User Manual Original instructions GV25 GV35 GV702 Company information: www.vipercleaning.eu info-eu@vipercleaning.com GV12066 (1) 2012-04-10 USER MANUAL ENGLISH TABLE OF CONTENTS Introduction... 4 Manual

More information

12/50 CENTRIFUGAL PUMPS FOR DC SUPPLY OPERATING INSTRUCTIONS

12/50 CENTRIFUGAL PUMPS FOR DC SUPPLY OPERATING INSTRUCTIONS 12/50 CENTRIFUGAL PUMPS FOR DC SUPPLY OPERATING INSTRUCTIONS Please leave this instruction booklet with the pump as it contains maintenance and safety information (Original Instructions) MODELS 12/50 INDEX.................

More information

USER GUIDE ENGLISH TOPSTART Ref. TSWZ, TSWRS or TSG Between 0.5 and 3 kw

USER GUIDE ENGLISH TOPSTART Ref. TSWZ, TSWRS or TSG Between 0.5 and 3 kw The TopStart is a compact electric coolant heater with circulating pump for marine engines, generating sets and all types of vehicles located inside or outside (protected place only). TABLE OF CONTENTS

More information

Acquaer Ltd. H-4900, Fehérgyarmat, Szatmári út 11. CENTRIFUGAL PUMP Instruction Manual ACm60 / ACm75 / ACm150 / ACm150B2

Acquaer Ltd. H-4900, Fehérgyarmat, Szatmári út 11. CENTRIFUGAL PUMP Instruction Manual ACm60 / ACm75 / ACm150 / ACm150B2 CENTRIFUGAL PUMP Instruction Manual ACm60 / ACm75 / ACm150 / ACm150B2 Congratulations on your purchase of a LEO Centrifugal Pump It is important that you read, fully understand and observe the following

More information

APPLICATIONS. For the accelerated circulation of hot water in heating circuits with duty point optimisation

APPLICATIONS. For the accelerated circulation of hot water in heating circuits with duty point optimisation OPERATING RANGE Flow rate of up to m /h Manometric head of up to m Max. operating pressure bar Min. intake pressure, bar at 9 C Water temperature range + at + C * EEI-Part, * for a ambient temperature

More information

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60 HG 675 X 60 HG 675 CX 60 HG 675 CN 60 HG 675 CW 60 1 2 1. : 93/68: 90/396: 2006/95/CE: 2004/108/CE: - 1935/2004:. 2002/95/CE: RoHS 2.,.,,,,...,. (,..)..,,.,. ( ),,, ;,,.,.....,.,,,,,,...,. (..),,.,..,.,,,,

More information

INSTALLATION AND MAINTENANCE MANUAL. Alcor FA

INSTALLATION AND MAINTENANCE MANUAL. Alcor FA INSTALLATION AND MAINTENANCE MANUAL IST 03 F 048-01 Alcor FA Aluminium electric radiators with heat transfer fluid EN Dear customer, Thank you for choosing our product. Read this manual carefully before

More information

USE AND INSTALLATION HANDBOOK

USE AND INSTALLATION HANDBOOK Date : 10/02/14 Rev. 01 PR.T : FG006176 USE AND INSTALLATION HANDBOOK SIMPLEX-UP CONTROL PANEL FOR 1 ELECTRIC PUMP WITH CURRENT CONTROL. SIMPLEX-UP Via Enrico Fermi, 8-35020 Polverara PD Tel.049/9772407

More information

Flomate Mains Boost Pump Installation & Maintenance Instructions

Flomate Mains Boost Pump Installation & Maintenance Instructions Flomate Mains Boost Pump Installation & Maintenance Instructions Please leave this instruction booklet with the owner as it contains important guarantee, maintenance and safety information PATENT APPROVED

More information

OPERATION & MAINTENANCE INSTRUCTIONS

OPERATION & MAINTENANCE INSTRUCTIONS SUBMERSIBLE PUMPS MODEL NO: PSV3A, PSV4A, PSSV2A & PVP11A PART NO: 7236042, 7236044, 7236050 & 7236060 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC07/17 iss 4 INTRODUCTION Thank you for

More information

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions Electronically controlled instantaneous water heater MCX: 27300, 27400 and 27600 models Installation instructions These appliances deliver water not exceeding 50 ºC in accordance with AS3498. 1. Overview

More information

Installation and operating instructions. DK energy storage and DK energy buffer

Installation and operating instructions. DK energy storage and DK energy buffer Installation and operating instructions DK energy storage and DK energy buffer Edition: 08-2015 1 Preliminary note With this DK energy storage / DK energy buffer you purchased a DK quality product. The

More information

SMHA Hatch High temperature fan HT-fan Installation and Maintenance

SMHA Hatch High temperature fan HT-fan Installation and Maintenance High temperature fan HT-fan Installation and Maintenance 22.8.2012 Contents 1. Important information 2. Safety notes 3. Technical description 4. Transport 5. Mounting instructions 6. Commissioning 7. Maintenance

More information

FHA 1100 A1 Domestic Water Pump

FHA 1100 A1 Domestic Water Pump FHA 1100 A1 Domestic Water Pump Translation of original operation manual 6 Before reading, unfold the page containing the illustrations and familiarise yourself with all functions of the device. / Translation

More information

Mechanical seals external, single or double, to DIN EN 12756

Mechanical seals external, single or double, to DIN EN 12756 INSTALLATION AND OPERATING MANUAL Translation of the original manual Series SCK Bearing pedestal group: 0 Mechanical seals external, single or Keep for future use! This operating manual must be strictly

More information

600W Hand Blender. Model: SP20160 (all colours) Helpline: v1.0. SP20160_IM.indd 1 26/07/ :38

600W Hand Blender. Model: SP20160 (all colours) Helpline: v1.0. SP20160_IM.indd 1 26/07/ :38 600W Hand Blender Model: SP20160 (all colours) Helpline: 01733 404703 v1.0 SP20160_IM.indd 1 26/07/2016 11:38 IMPORTANT INFORMATION - RETAIN FOR FUTURE USE When using any electrical appliance, basic safety

More information

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans Installation and Maintenance IPX4* The EMC Directive 2014/30/EU The Low Voltage Directive 2014/35/EU 1.0 SAFETY INFORMATI The installation

More information

DEHUM3 INSTRUCTION MANUAL SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

DEHUM3 INSTRUCTION MANUAL SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE Rotary Desiccant Dehumidifier DEHUM3 INSTRUCTION MANUAL SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE GENERAL INFORMATION Packaging Please DO NOT dispose of any packaging until you have checked the appliance

More information

OPERATION AND MONTAGE MANUAL ROOF FANS

OPERATION AND MONTAGE MANUAL ROOF FANS NO RF/U/2017 (ENGLISH) (valid since 13.10.2017) ROOF FANS RF / RFV Venture Industries Sp. z o.o. is not responsible for any damage caused by improper use of the fan and reserves the right to modify this

More information

ELTA FANS IN-LINE MIXED FLOW FAN IMF100 / 125 / 150 / 200 INCLUDING MODELS WITH BUILT-IN-RUN-ON TIMERS T

ELTA FANS IN-LINE MIXED FLOW FAN IMF100 / 125 / 150 / 200 INCLUDING MODELS WITH BUILT-IN-RUN-ON TIMERS T ELTA FANS IN-LINE MIXED FLOW FAN IMF100 / 125 / 150 / 200 INCLUDING MODELS WITH BUILT-IN-RUN-ON TIMERS T Installation and Maintenance Instructions. THESE INSTRUCTIONS MUST BE READ FULLY BEFORE COMMENCING

More information

Lowara ecocirc and ecocirc PREMIUM

Lowara ecocirc and ecocirc PREMIUM Lowara and PREMIUM THE REVOLUTIONARY HIGH EFFICIENCY CIRCULATORS FOR DOMESTIC HEATING WITH THE SIMPLE AND SHAFTLESS SPHERICAL MOTOR DESIGN AND PATENTED ANTI-BLOCK TECHNOLOGY How can efficiency work even

More information

Operating instructions

Operating instructions Operating instructions (Translation of the original operating instructions) Type TEKA FILTERCUBE-MV TEKA Absaug- und Entsorgungstechnologie GmbH Industriestraße 13 D-46342 Velen Postfach 1137 D-46334 Velen

More information

Electronically controlled instantaneous water heater. MCX: 27300, and models. Instructions for the user

Electronically controlled instantaneous water heater. MCX: 27300, and models. Instructions for the user Electronically controlled instantaneous water heater MCX: 27300, 27400 and 27600 models Instructions for the user These appliances deliver water not exceeding 50 ºC in accordance with AS3498. 1. Overview

More information

Lowara ecocirc and ecocirc PREMIUM THE NEW HIGHLY EFFICIENT CIRCULATORS WITH THE PATENTED ANTI-BLOCK-TECHNOLOGY

Lowara ecocirc and ecocirc PREMIUM THE NEW HIGHLY EFFICIENT CIRCULATORS WITH THE PATENTED ANTI-BLOCK-TECHNOLOGY NE W Lowara ecocirc and ecocirc PREMIUM THE NEW HIGHLY EFFICIENT CIRCULATORS WITH THE PATENTED ANTI-BLOCK-TECHNOLOGY Ecocirc_Premium_uk.indd 1 28/10/13 12.26 How can efficiency even w The simple spherical

More information

INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE (GB)

INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE (GB) INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE (GB) Pag. 1 Fig - Fig. - Abb.- Fig.- Fig.- Фиг.- Obr.- Fig.- Εικ. - Joonis - Kuva - Sl. -.ábra - Fig. -.att. - Afbeelding - Fig. - Rys.- Fig.- Fig. - Схема

More information

PRIUX HOME D. High-efficiency double circulating pumps Heating Air conditioning 50 Hz OPERATING RANGE APPLICATIONS BENEFITS

PRIUX HOME D. High-efficiency double circulating pumps Heating Air conditioning 50 Hz OPERATING RANGE APPLICATIONS BENEFITS OPERATING RANGE Flow rate of up to 7 m /h* Manometric head of up to 8 mwc Max. operating pressure bar Min. suction pressure, bar at 9C Temperature range -C at 9C Max. ambient temperature +C EEI-Part Priux

More information

SUBMERSIBLE DIRTY WATER PUMP

SUBMERSIBLE DIRTY WATER PUMP SUBMERSIBLE DIRTY WATER PUMP MODEL NO: DWP100A, DWP150A, DWP200A PART NO: 7230098, 7230099, 7230100 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS1117 - ISS 2 INTRODUCTION Thank you for

More information

submersible water pumps

submersible water pumps instructions for submersible water pumps model no s: WPC100.V2 WPC100A.V2 WPC150.V2 WPC150A.V2 WPC235.V2 WPC235A.V2 WPC250 WPC250A Thank you for purchasing a Sealey product. Manufactured to a high standard,

More information

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES Bucket Fan 420 Bucket Fan 1055 Bucket Fan 1460 420 1055 1460 2 Bucket Fan CONTENT INTRODUCTION 3 USE 3 WHAT S INCLUDED IN THE BOX 3 DESIGNATION

More information

Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS

Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS PW1370TD 2 EN Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS 3 E3 E1 C3 A1-A2-A3-A4 B4 B1 B5 B2 C1 B3 D 1 4 1 2 3 4 5 6 7 Ø13

More information

ONE. User Manual. Heating Element and Electric Radiator

ONE. User Manual. Heating Element and Electric Radiator ONE User Manual Heating Element and Electric Radiator Electric radiator Guide to safe installation 1. Do not install the radiator over or under an electrical socket point. 2. Your electric heater should

More information

NON-SUBMERSIBLE WATER PUMP

NON-SUBMERSIBLE WATER PUMP NON-SUBMERSIBLE WATER PUMP MODEL NO: CEB103 PART NO: 7230327 OPERATION & MAINTENANCE INSTRUCTIONS LS0114 INTRODUCTION Thank you for purchasing this CLARKE Water Pump, which is a general purpose pump, suitable

More information

EVP61/91/101/121. Extractor. Installation, use and maintenance.

EVP61/91/101/121. Extractor. Installation, use and maintenance. EVP61/91/101/121 Extractor Installation, use and maintenance www.cda.eu Important The manufacturer cannot be held responsible for injuries or losses caused by incorrect use or installation of this product.

More information

Wind. Service instruction

Wind. Service instruction Wind Service instruction E BAUBERG Company is happy to offer your attention the window axial Blauberg Wind fan. The solid team of high-qualified professionals with many years of working experience, technological

More information

INDEX WARNINGS AND RECOMMENDATIONS 2 COMPLIANCE DECLARATIONS 3 RANGE AND SIZES 3 ELECTRICITY SUPPLY 3 INSTALLATION 4 INSTRUCTIONS FOR UNINSTALLING

INDEX WARNINGS AND RECOMMENDATIONS 2 COMPLIANCE DECLARATIONS 3 RANGE AND SIZES 3 ELECTRICITY SUPPLY 3 INSTALLATION 4 INSTRUCTIONS FOR UNINSTALLING Tuscany TUS1500 INDEX WARNINGS AND RECOMMENDATIONS 2 COMPLIANCE DECLARATIONS 3 RANGE AND SIZES 3 ELECTRICITY SUPPLY 3 INSTALLATION 4 INSTRUCTIONS FOR UNINSTALLING THE RADIATOR 5 INSTRUCTIONS FOR USE 6

More information

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans Installation and Maintenance IPX4* The EMC Directive 2014/30/EU The Low Voltage Directive 2014/35/EU 1.0 SAFETY INFORMATION

More information