Trade Product List 2013 BIOMASS ACCESSORIES
|
|
- Noel Payne
- 5 years ago
- Views:
Transcription
1 Trade Product List 2013 BIOMASS ACCESSORIES
2 BIOMASS SYSTEM COMPONENTS Constant Temperature Control Accessories CONSTANT TEMPERATURE CONTROL PRODUCTS Order Code Description of Package and Contents Pictures CSB00001 Constant Temperature Valve Actuator Electronic actuator adaptor kit for 3-way valves (note: valve bought separately) to provide Biomass Constant Temperature Control. Touch sensitive keypad and digital display for set-up and temperature display. Fits a wide range of mixing and diverting valves. See Technical Appendix I for more details. 3-Way and 4-Way Mixing Valves Mixing valves compatible with the above actuator. CSB00002 CSB00003 CSB00004 CSB Way Mixing Valve : 1 KV8 3-Way Mixing Valve : 1¼ KV12 4-Way Mixing Valve : 1 KV8 4-Way Mixing Valve : 1¼ KV12 Temperature Sensors for Biomass Applications CSB00006 CSB00007 CSB00008 CSB00009 Exhaust Gas Temp Sensor CF/Pt 90mm (400 C max) Outside Sensor AF/Pt [49 x 26 x 14 mm] Immersion Sensor TF/Pt [Ø6 x 50mm] 3m Silicone (180 C max) Surface Sensor VF/Pt [23 x 14 x 42 mm] 3m Silicone (180 C max) Loading Pump for Biomass Boiler to Cylinder Integrated and compact loading pump providing constant temperature control and circulation with a thermostatic unit set at either 55 C or 72 C. Includes a recirculation pump that connects solid fuel boilers (pellets, wood, chips.) to one or more hot water storage tanks. See Technical Appendix III for more details. CSB CSB CSB CSB Fittings : Anti-Condensation Pump Set (55 C Mixing) 1 Fittings : Anti-Condensation Pump Set (72 C Mixing) 1¼ Fittings : Anti-Condensation Pump Set (55 C Mixing) 1¼ Fittings : Anti-Condensation Pump Set (72 C Mixing)
3 Order Code Description of Package and Contents Pictures CPS3 Biomass Loading Pump set Integrated Pumping set that comes complete with mixing valve for controlled temperature loading from the biomass boiler. Includes a Wilo Yonos para 25/6 A Class pump, Isolation valves, check valve and built in temperature gauges. The units have integrated mixing valves that are preconfigured to open at a set temperature. Options are available for opening temperatures as follows : CSB CSB Opening Temperature : 55 C Opening Temperature : 70 C See Technical Appendix IV for more details. CSB Constant Temperature Controller Controller for constant temperature with graphical user interface to provide constant boiler return-pipe temperature control and storage tank loading. Suitable for all kind of solid fuel and pellet boiler systems with ability to manage layered storage tank loading. See Technical Appendix II for more details.
4 HEAT METERING EQUIPMENT Order Code Description of Package and Contents Pictures F96 Plus Ultrasonic Heat Meter Digital Ultrasonic Heat Meter complying with MID Certificate Class 2 requirements for OFGEM and RHI Compliance requirements (MID Certificate Available including written confirmation from OFGEM that meter complies with RHI requirements). This meter can be ordered and supplied calibrated for WATER, or for premixed GLYCOL Fluids (i.e. Tyfocor LS). Optional MBUS DataLogging (call for more details). CSB00010 CSB00011 CSB00013 CSB00014 G¾ B Fittings with Nominal Flow Rate (Q p ) 0.6 : WATER G¾ B Fittings with Nominal Flow Rate (Q p ) 0.6 : GLYCOL G1 B Fittings with Nominal Flow Rate (Q p ) 0.6 : WATER G1 B Fittings with Nominal Flow Rate (Q p ) 0.6 : GLYCOL F96 Accessories : Additional accessories and non-standard sizes and variants are available - See Technical Appendix V for more details. Important Note : Other non-standard sizes are available, however, the lead time can be up to approx. 6 weeks during busy periods.
5 THERMACONTROL PUMPING SYSTEMS ThermaControl Family of Pump Sets Provide total control and flexibility with a specific engineered solution for multiple pumped circuits and providing the critical link for bivalent systems. Multiple outputs provide complete Thermal Control for radiant panel radiator circuits, zoned under floor heating circuits (with EuP ready low energy pump and pre-set temperature mixing) Order Code Description of Package and Contents Pictures CSB00034 ThermaControl Primary Heating Pump Set CPS1 Wilo Yonos para 25/6 A Class pump. Isolation valves. Check valve. Temp gauges. See Appendix IV for more details. CSB00035 ThermaControl UNDERFLOOR HEATING Pump Set CPS2 Wilo Yonos para 25/6 A Class pump. Isolation valves. Check valve. Temp gauges. Mixing range 36C - 60C. See Appendix IV for more details. ThermaControl Biomass Loading Pump Set CPS3 w/mixing valve for controlled temperature loading from the biomass boiler. Wilo Yonos para 25/6 A Class pump. Isolation valves. Check valve. Temp gauges. CSB CSB Opening Temperature : 55 C Opening Temperature : 70 C See Appendix IV for more details. ThermaControl Fresh Water Station Pump Set FWS The optimum solution for Fresh Water Delivery requirements. With a Primary Loop Max. flow rate of 40 litres / min and a secondary loop set temperature in the range from 35 C to 60 C this integrated unit is ideal for Fresh Water applications in domestic and small commercial applications. Supplied with Single Pump and 20 plate heat exchanger and controller. There is also an option for a unit with two pumps to additionally provide sanitary recirculation. See Appendix VI for more details. CSB00037 CSB00038 CSB00039 CSB00040 ThermaControl FWS Single Pump Low Loss Headers ThermaControl HEADER 2 way (insulated) ThermaControl HEADER 3 way (insulated) Header to Pump Connector Set (2 Connections 1½ x 1 ) [Set required with each pump set if used with Header]
6 TECHNICAL APPENDIX I ACC10 - CONSTANT TEMPERATURE VALVE ACTUATOR The ACC10 controller is intended for achieving constant temperature control for biomass boiler systems, i.e. controlling the water temperature as it enters the boiler. The ACC10 controls the automatic operation of the mixing valve. It is complete with an in-built digital display which displays both controller set-up and temperature information. ACC10 Specifications : Adjustable Temperature Range 0-99 C Selection of opening direction and controller sensitivity Dimensions [w x h x d] : 101mm x 84mm x 88mm Heating or Cooling modes Indication of Direction of Valve Movement Torque 6Nm Running Speed 2 minutes Diverting / Mixing Valve Compatibility : A variety of different Installation Sets allow the ACC10 to be fitted to a wide range of Diverting/Mixing Valves as detailed in the table below. Table A : Ordering Codes for the ACC10 Installation Sets to ensure a compatible fit with various diverting and mixing valves from a range of manufacturers.
7 Application Configuration Schematics : Solid fuel boiler, heat accumulator, constant return-pipe temperature control Boiler, mixing heating circuit, constant stand-pipe temperature control Heat exchanger, constant stand-pipe temperature control Heat exchanger, constant stand-pipe temperature control Installation and Fitting Guide :
8 TECHNICAL APPENDIX II SCC40 CONSTANT TEMPERTURE CONTROLLER The SCC40 controller is intended for constant boiler return-pipe temperature control and storage tank loading. SCC controllers are applicable for all kinds of solid fuel and pellet boiler systems with the ability to manage layered storage tank loading. Layered storage tank loading increases energy gain at boiler start-up and consequentially increases loading of the heating system. These controllers are simple to install and use with the settings configured via a commissioning wizard and a digital graphical interface. SCC40 Specifications : Power supply 230 V ~, 50 Hz Consumption < 5 VA Inputs o 6 x Temperature (Pt 1000) o 1 x pulse input Outputs o 2 x Triac for speed control (R2) o 4 x relay (R1) Clock backup Battery CR2032 (Li - Mn) 3 V Clock accuracy +/- 1 s (24 h) by 20 C Degree of protection IP20 / EN60529 Safety Class I according to EN Controller housing ASA - thermoplastics Dimensions [w l h] : 113 x163 x 48 mm Ambient temperature 0-40 C
9 Application Configuration Schematics : Solid fuel boiler, heat accumulator, constant returnpipe temperature control Pellet boiler, heat accumulator, constant return-pipe temperature control Solid fuel boiler, heat accumulator, constant returnpipe temperature control, staged tank loading Pellet boiler, heat accumulator, constant return-pipe temperature control, staged tank loading Solid fuel boiler, heat accumulator, constant returnpipe temperature control, staged tank loading Pellet boiler, heat accumulator, constant return-pipe temperature control, staged tank loading
10 TECHNICAL APPENDIX III BIOMASS BOILER TO CYLINDER LOADING PUMP A simple and compact thermostatic unit complete with recirculation pump that connects a solid fuel heater (pellets, wood, chips ) to one or more hot water tanks and is an effective anti-condensation / anti-thermal shock system that uses the maximum return of the heater to obtain energy-saving results. The unit keeps the boiler area at highest possible temperature in a manner that stops the formation of acid condensate and guarantees stratified filling of the accumulation tank without mixing water internally. The thermostatic elements used have different opening temperatures that range from 63 to 87 C. In addition, the natural circulation between heater and storage can be put to good use even when the pump is stopped. This is an important feature that ensures the heater is provided with a minimum flow of cooling water in the event of a failure of the electricity supply. Technical Specifications : Pump Data: Brand Wilo Type Star-RS 15/6-130 System type Single Pump Operation mode 1 Nom. pressure PN10 Min. fluid temperature 263 K Max. fluid temperature 383K Motor Data: Energy efficiency class Nom. power P kw Absorbed power P kw Nom. no. revs l/min Nom. voltage 1~230 V, 50 Hz Max. absorbed current 0.37 A Protection class IP 44 Permitted voltage tolerance +/- 10% Material: Shaft X40 Cr 13 Impeller Polypropylene Bearing Graphite
11 Installation Guide : Operation Guide : STARTING THE HEATER The heater is at a temperature of below 78 C. The cartridge has not started opening yet. The self-recirculation valve cone seals delivery to the tank thanks to the pump pressure. MIXING The heater has reached its working temperature, approx. 85 C. The cartridge opens and allows cold water to enter from the tank. The mixed water at the bottom of the heater has a temperature of around 70 C. When the heater power, therefore the temperature, increases in the loading pump body, the cartridge opens to allow more cold water to enter.. FULL OPENING When the heater is completely full, boiling water enters from the cold section of the body In this case the piston opens fully towards the tank, completely closing the passage towards the high part of the heater. The whole flow now passes through the tank. This operation is extremely important because it is essential for completely filling the tanks. SELF-RECIRCULATION If the current going towards the pump is stopped for some reason, or if the pump is faulty, the non-return valve that is integrated for selfrecirculation opens, allowing the water to circulate naturally between the heater and the tank. This stops the water from boiling in the heater if the tank is not completely full. If the power is disconnected for long periods, the heater can still be switched on to heat the dwelling. It also avoids the risk of the heater water being directly consumed and the associated dangers.
12 TECHNICAL APPENDIX IV THERMACONTROL FAMILY OF INTEGRATED PUMPSETS The ThermaControl Range of Integrate PumpSets places complete control of the entire heating system into your control. In combination with the SolarLogic PumpSets the ThermaControl Units allow you to specify a Universal Heating System that integrates multiple generation and delivery technologies into an integrated heating system. The ThermaControl and SolarLogic PumpSets are the ideal solution to all your domestic and commercial applications to allow the simple integration of Solar Thermal, Biomass and Underfloor Heating and Fresh Water delivery technologies. Primary Heating PumpSets for Radiator Loops Biomass Heating Circuit Underfloor Heating PumpSet Fresh Water Pumping Station
13 THERMACONTROL INTEGRATED BIOMASS LOADING PUMPSET ThermaControl Biomass Loading Pump set Integrated Pumping set that comes complete with mixing valve for controlled temperature loading from the biomass boiler. Includes a Wilo Yonos para 25/6 A Class pump, Isolation valves, check valve and built in temperature gauges. The units have integrated mixing valves that are preconfigured to open at a set temperature. Options are available for the Thermostatic Mixing Valve opening temperatures at any of ; 45 C, 55 C, 60 C, 70 C or 80 C Installation Guide Biomass Heating Circuit
14 THERMACONTROL INTEGRATED PRIMARY HEATING PUMPSET ThermaControl Primary Heating Pump Set CPS1 Wilo Yonos para 25/6 A Class pump. Isolation valves. Check valve. Temp gauges. Installation Guide Primary Heating PumpSets for Radiator Loops
15 THERMACONTROL INTEGRATED UNDERFLOOR HEATING PUMPSET ThermaControl UNDERFLOOR HEATING Pump Set CPS2 Preassembled and integrated Underfloor Heating Pump Set to provide ultimate control in a compacy unit. The ThermaControl Underfloor Heating Pump Set comprises a Wilo Yonos para 25/6 A Class pump with integrated Isolation Valves, Check Valve and Temperature Gauges. This versatile unit allows for temperature mixing in the range from 36 C to 60 C making it ideal for most underfloor heating loops. Installation Guide Underfloor Heating PumpSet
16 THERMACONTROL FRESH WATER STATION PUMPSET ThermaControl Fresh Water Station Pump Set FWS The optimum solution for Fresh Water Delivery requirements. With a Primary Loop Max. flow rate of 40 litres / min and a secondary loop set temperature in the range from 35 C to 60 C this integrated unit is ideal for Fresh Water applications in domestic and small commercial applications. The Standard unit is Supplied with Single Pump and 20 plate heat exchanger and controller. There is also an option for a unit with two pumps to additionally provide sanitary recirculation. Fresh Water Station Specifications :
17 Fresh Water Station Installation Guide Fresh Water Pumping Station Key Features of the Single Pump Unit :
18 TECHNICAL APPENDIX V F96 PLUS ULTRASONIC HEAT METER (MID CLASS 2 COMPLIANT) F96 Plus Ultrasonic Heat Meter Digital Ultrasonic Heat Meter complying with MID Certificate Class 2 requirements for OFGEM and RHI Compliance requirements. MID Class 2 Certificate and written confirmation from OFGEM that the F96 Plus meter complies with RHI requirements are available upon request. OFGEM or DECC should be consulted in order to determine for which systems metering is required. This meter can be ordered and supplied calibrated for water, or for Tyfocor LS pre-mixed glycol fluid, which should be specified at the point of ordering. Technical Specifications : Digital Display (8-Characters) to display information : Accumulated energy Volume Flow rate Power output Flow temperature Return temperature Temperature difference Operating hours Error code Display test Reading of the energy counter for the respective target dates Monthly maximum of power and flow (with the date) Important device data (M-Bus addresses etc.) Meter reading of the two additional pulse outputs Actual tariff values Tariff value as per the target date Consumption values, tariff values, maximum values of the respective months
19 Product Range and Variations: The tables below detail the most common product variations in the F96 Product Range including the accessory components. Other variations and sizes are also available so please contact us if the particular variant required is not listed. PAIR PLC120 Temperature Sensor (matched pair) for 2 CSR00018 (LA ) Heat Meter
Solar controllers Energy under control
www.seltron.eu 2015 PROMATIC SGC Solar controllers Energy under control For domestic hot water. 14 PROMATIC SGC Solar controllers 15 PROMATIC SGC Solar controllers HIGHLIGHTS ycontrol of up to 65 different
More informationPROMATIC WDC Heating controllers Energy under control
www.seltron.eu 205 PROMATIC WDC Heating controllers Energy under control 36 Made for warmth. PROMATIC WDC Heating controllers 37 PROMATIC WDC Heating controllers HIGHLIGHTS ycontrol of up to 52 different
More informationManual and installation instructions. Function. Operating phase
LADDOMAT M120 Manual and installation instructions Thermal layering Function Thanks to its design and control features, the Laddomat M120 means optimal thermal layering in storage tanks, with a low and
More informationHEAT INTERFACE UNITS (Sanitary Hot Water Only)
HEAT INTERFACE UNITS (Sanitary Hot Water Only) T-FAST i20 (Sanitary Hot Water Only) 20 The T-Fast i20 is an instantaneous domestic hot water production module that produces a flow rate of 20L per/min at
More informationEFFICIENCY THERMAL STORAGE SYSTEMS
JASPI ThermoStore 500, 700, 1500, 2000 & 3000 litre HIGH EFFICIENCY NEW! Efficient, durable & light Stainless Steel hot water coils www.jaspi.co.uk JASPI-ThermoStore 500, 700, 1500, 2000 & 3000 litre THERMAL
More informationSolar heating systems
03 energy efficiency Compact, "ALL-IN-ONE" solar system Solar panel for swimming pools Hydraulic components Drain-Unit: dual hydraulic unit with drain back system Drain-Unit: hydraulic unit with drain-back
More informationT. +44 (0) E.
Twin Plate Heat interface unit for indirect heating and instantaneous domestic hot water with electronic thermostatic control. Designed for wall-mounting. Application The is the complete solution for hot
More informationModuSat TP. Energy. Heat Interface Units
Energy Twin Plate Heat interface unit for indirect heating and instantaneous domestic hot water with electronic thermostatic control. Designed for wall-mounting. Application The is the complete solution
More informationheat interface units A BOILER WITHOUT A FLAME HIU Single PHE options
A BOILER WITHOUT A FLAME HIU Single PHE options heat interface units Communal Heat Networks A central boiler house will generate heat which is distributed through a network of pipe to each home or apartment
More informationModuSat TP. Energy. Heat Interface Units
Energy Twin Plate Heat interface unit for indirect heating and instantaneous domestic hot water with electronic thermostatic control. Designed for wall-mounting. Application The is the complete solution
More informationWood Boiler Plumbing Schematics
Wood Boiler Plumbing Schematics Solo Plus Froling FHG Solo Innova Excel Multi-Fuel 2 TABLE OF CONTENTS Section Page 1.0 Introduction..4 2.0 Plumbing Diagrams....5 2.1 Plumbing Example-Solo/Excel 1........5
More informationProduct range Code HE1 Connection and energy management compact unit without anti-condensation valve
Connection and energy management compact unit 2850 series ACCREDITED CALEFFI 01259/14 GB ISO 9001 FM 21654 ISO 9001 No. 0003 Function The connection and energy management compact unit enables combining
More informationheat interface units A BOILER WITHOUT A FLAME
A BOILER WITHOUT A FLAME heat interface units Communal Heat Networks A central boiler house will generate heat which is distributed through a network of pipe to each home or apartment in the building.
More informationMetering systems 0548EN April 2014
08EN April 0 0U8 GEY - Y - Y (GE- series) 900 000/ 00 00A/ 800 00L/ Versions and product codes Product code Type Heat exchanger nominal power GEY, - GEY and production GEY and production Table - Product
More informationCALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB
4 RESET ON DHW CH FAULT SATK wall-mounted heat interface unit Fitted for connection to DHW storage SATK4 series ACCREDITED CALEFFI 6/4 GB ISO 9 FM 64 ISO 9 No. The latest generation of heat interface units
More informationT. +44 (0) E.
ModuSat Single Plate-Double Circuit (SPDC) Heating Interface Units The Evinox ModuSat satellite heating system has been designed to provide apartments and communal housing developments with independent
More informationJASPI GTV & Oval thermal storage
JASPI GTV & Oval thermal storage Jaspi GTV thermal storage tanks Classy and efficient, the GTV tanks are suitable for new applications as well as heating system renovations for expanding water space and
More informationTank systems. Layered tank Solar layered tank Hygienic layered tank Modular layered tank Hot water tank NEW:
Tank systems Layered tank Solar layered tank Hygienic layered tank Modular layered tank Hot water tank NEW: NEOPOR AND FLEECE INSULATION SENSOR TERMINAL STRIP ADJUSTABLE FEET www.froeling.com Energy management
More informationComponents for solar heating systems
solarorkli Components for solar heating systems Components for heating and plumbing Components for solar heating systems Manifolds and distribution equipment Thermostatic valves Manual valves Motorised
More informationDescription of functions
Description of functions Laddomat 21 is designed to......allow the boiler to reach a high working temperature soon after firing....to preheat the cold tank water in the bottom of the boiler so that the
More informationTechnote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional.
Page 1 of 5 Application The Single Plate heat interface unit (HIU) for the generation of instantaneous domestic hot water and the direct supply of space heating. This HIU provides hydraulic separation
More informationJaspi GTV and Jaspi Oval. Jaspi Oval thermal storage tanks
Jaspi GTV and Jaspi Oval thermal storage tanks Jaspi GTV thermal storage tanks Classy and efficient, the GTV tanks are suitable for new applications as well as heating system renovations for expanding
More informationPressurisation units & expansion vessels
Pressurisation units & expansion vessels Pressurisation units The new generation of microprocessor controlled pressurisation units Standard Unit/Advanced Unit These microprocessor controlled pressurisation
More informationHot Water Energy Storage THE HOT WATER PEOPLE HEAT INTERFACE UNIT ENGINEERED FOR ULTIMATE HEATING COMFORT AND MAXIMUM SYSTEM EFFICIENCY
Hot Water Energy Storage HEAT INTERFACE UNIT ENGINEERED FOR ULTIMATE HEATING COMFORT AND MAXIMUM SYSTEM EFFICIENCY THE HOT WATER PEOPLE Hot Water Energy Storage THE HOT WATER PEOPLE Providing premium hot
More informationValves, controls + systems. Innovation + Quality. Stations for solar energy and solid fuel boilers Product range
Valves, controls + systems Innovation + Quality Stations for solar energy and solid fuel boilers Product range Stations for solar energy and solid fuel boilers Content Page Summary Stations for solar energy
More informationHyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1
HyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1 INSTALLATION, COMMISSIONING AND OPERATING INSTRUCTIONS Contents Unit as delivered
More informationBOILER COMPLETE FORCED CIRCULATION SYSTEMS. solair. Inspired by the sun. Save your energy.
BOILER COMPLETE FORCED CIRCULATION SYSTEMS solair Inspired by the sun. Save your energy. FORCED CIRCULATION SYSTEM 00lt Dual Circulation Pump 00lt Forced Circulation System 0 0 Vertical Enameled Tank 00lt
More informationFCHM Hydromatic Pump Control Module
FCHM Hydromatic Pump Control Module Use To maintain and control water pressure, within a pumped system, for the supply to industrial processes and heating systems. Ensures constant flow and pressure to
More informationWALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C
ALKON 50 C ALKON 70 C WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) OUTPUT RANGE from 50 to 560 kw (in battery) WORKING TEMPERATURE no limit on
More informationUNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2. Version: 2018_07_19_v2.2
UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2 Version: 2018_07_19_v2.2 Abstract This is a quick reference guide for selecting the UniQ range of heat batteries for the required application. For designing a
More informationProtection and Control of Solid Fuel Boilers
Protection and Control of Solid Fuel Boilers thermal relief valves thermostatic valves and pump stations draft regulators www.regulus.eu BOILER PROTECTION AGAINST OVERHEATING Solid fuel boilers may get
More informationTechnical Product Guide
FMU - Floor Mixing Unit Boxed set pre-assembled for immediate installation: The FMU Floor Mixing Unit integrates both temperature and flow management, making the single piece unit very easy to install,
More informationproduct overview ProControl
product overview ProControl 2016 product overview ProControl 2016 4 The company AFRISO Sp. z o.o. was founded in 1997. Since that time we keep doing our best to increase AFRISO brand awareness among Installers.
More informationSmart temperature control solutions
Smart temperature control solutions State-of-the-art heating and cooling solutions, expertise & know-how combined with top quality and superior customer service. 1 1 8 7 5 9 6 10 4 3 2 www.vexve.com Contents
More informationRENEWABLE ENERGY THERMAL SOLAR ENERGY. RENEWABLE ENERGY...pag. 05
THERMAL SOLAR ENERGY CATALOGUE OCTOBER 2008 INDEX RENEWABLE ENERGY THERMAL SOLAR ENERGY RENEWABLE ENERGY...pag. 05 SISTEMA CS 25 RN TAU... pag. 6 SISTEMA CS 25 RN - CS 25 RN PLUS... pag. 8 SISTEMA CSL
More information521 Series. MixCal adjustable three-way thermostatic mixing valve. Installation, commissioning and service instructions
MixCal adjustable three-way thermostatic mixing valve 37. www.caleffi.com Copyright 15 Caleffi 51 Series Installation, commissioning and service instructions Function The Caleffi MixCal three-way thermostatic
More informationCS TSV MIX REGULUS PUMP STATION - for boilers and heating systems
Instruction Manual CS TSV MIX REGULUS PUMP STATION - for boilers and heating systems EN v 1.1 CONTENTS: 1 Introduction 3 2 Connection dimensions of CS TSV MIX Regulus 3 3 Function description of CS TSV
More informationCS TSV MIX-REGULUS CS TSV MIX REGULUS. Installation and Operation Manual CS TSV MIX REGULUS PUMP STATION - for boilers and heating systems
www.regulus.eu CS TSV MIX-REGULUS Installation and Operation Manual CS TSV MIX REGULUS PUMP STATION - for boilers and heating systems EN CS TSV MIX REGULUS CONTENTS: 1 Introduction 3 2 Connection dimensions
More informationXcel HEATBANK Thermal Store The solution to multi-fuel heating. Renewable Energy Solutions
Xcel HEATBANK Thermal Store The solution to multi-fuel heating Renewable Energy Solutions Description of Standard Options Xcel HEATBANK Thermal Store Size and Capacity 01 02 The Xcel HEATBANK thermal store
More informationShoebox Heat Pump. Installation and Commissioning Manual
Heat Pump Warranty Fault Finding Commissioning Introduction Shoebox Heat Pump and Commissioning Manual Copyright 2016 Kensa Heat Pumps Ltd Page 1 of 36 Introduction Commissioning Fault Finding Warranty
More informationTechnical Data Sheet for Sunergy SOLAR ENERGY PROCESSOR Model SEP3G10
Technical Data Sheet for Sunergy SOLAR ENERGY PROCESSOR Model SEP3G1 Minus7 equipment and Systems are to be designed, installed and maintained by Minus7 personnel only. Contents General Description! 2
More informationSirius FS. Working towards a cleaner future
Sirius FS Floor Standing Stainless Steel Condensing Boilers Single Boiler Applications: 50 to 160kW Modular Boiler Applications: up to 640kW Working towards a cleaner future heating specialists 1. Product
More informationECL Comfort V a.c. and 24 V a.c.
230 V a.c. and 24 V a.c. Description and application The controller is designed for easy installation: one cable, one connector. The controller has a customdesigned display with backlight. For a quick
More informationHeat Pump. Installation and Commissioning Manual
Heat Pump Warranty Fault Finding Commissioning General product Introduction Manual High Temperature Single Compressor Compact Heat Pump and Commissioning Manual Copyright 2016 Kensa Heat Pumps Ltd Introduction
More informationStainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW
Stainless steel range of condensing boilers Outputs from 50kW to 660kW Designed to meet carbon reduction targets Lifetime service and support Totally dependable. page 1 www.pottertoncommercial.co.uk Contents
More informationCALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB
Set point thermostatic regulating unit 8 series FM 65 00 CALEFFI 090/8 GB replaces dp 090/5 GB Function The thermostatic regulating unit is made to be used in radiant panel systems, in combination with
More informationSamsung Eco Heating System
Samsung Eco Heating System Pre Sales Technical Information Powerful and eco-friendly air to water solutions for heating 2 Welcome This pre-sales manual has been developed for both the installer and end
More informationMaincor Air Temperature Controls AIR TEMPERATURE CONTROL
AIR TEMPERATURE CONTROL Overview In multi-zone systems, a thermostat is positioned in the room which is being heated and is set to the required temperature. Once the room gets up to the pre-set temperature,
More informationHEATBANK Xcel Thermal Store The solution to multi-fuel heating. Renewable Energy Solutions
HEATBANK Xcel Thermal Store The solution to multi-fuel heating Renewable Energy Solutions A Leading Supplier of Renewable Heat Products and Flue Systems 0333 999 7974 // www.specflue.com Suitable for simultaneous
More informationHT V2 HT Split
Scroll compressor Refrigerant R07C Aqu@Scop HT V Aqu@Scop HT Split High Temperature Air-to-Water Heat Pumps Models -, -7 and 8-9.0 to 7.9kW Aqu@Scop HT V / Aqu@Scop HT Split Installation examples - Single
More informationAluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support
Aluminium range of condensing boilers Outputs from 30kW to 600kW Designed to meet carbon reduction targets Lifetime service and support Works every time. www.pottertoncommercial.co.uk Aluminium range of
More informationAir Source Heat Pump Installation and Maintenance Manual
Air Source Heat Pump Installation and Maintenance Manual Model Numbers: AroTHERM VWZAI wiring centre VRC700 remote controller Scan this code to go directly to our YouTube channel 2016 b 1 The Outdoor Unit
More informationCALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA
Thermostatic mixing valves with replaceable cartridge for centralized systems 3, 3 series CCREDITED ISO 9 FM ISO 9 No. 3 /3 N Replaces / N Function The thermostatic mixing valve is used in systems producing
More informationECL Comfort V a.c. and 24 V a.c.
230 V a.c. and 24 V a.c. Description and application In heating applications the can be integrated with the Danfoss Link solution via the DLG interface for use in single-family applications. The controller
More informationC B SOLARTHERMAL. Solar thermal systems
66 66 Steca Elektronik GmbH 87700 Memmingen Germany Fon +49 (0) 81 8558-0 Fax +49 (0) 81 8558-12 www.stecasolar.com 67 E A D C B Legend: A Collector B Solar Station C Storage tank D Central-heating boiler
More informationfor relative humidity and temperature with calibration certificates
1 859 1859P01 1859P02 QFA4160 AQF4150 Symaro Room Sensor for relative humidity and temperature with calibration certificates QFA4160 Operating voltage AC 24 V or DC 13.5...3 Signal output DC 0...10 V for
More informationTwin Compressor Compact Heat Pump. Installation and Commissioning Manual
Heat Pump Warranty Fault Finding Commissioning General product Introduction Manual Twin Compressor Compact Heat Pump and Commissioning Manual Copyright 2016 Kensa Heat Pumps Ltd Page 1 of 42 Introduction
More informationLK Electric Boiler - 4,5
LK Electric Boiler -, Design LK Electric Boiler, kw is a wall-mounted electric boiler, intended primarily for low-temperature heating systems, e.g. under floor heating. LK Electric Boiler, kw is delivered
More information80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.
product selection data Compact comfort module DHW management possibility Multi zone option control Easy installation Comfort module with two-zone kit Single-zone comfort module Comfort Module Range for
More informationInstallation, commissioning and servicing instructions. Technical Characteristics. -Lead Plumbing Law Certifi ed by IAPMO R&T
www.caleffi.com 37. MixCal adjustable three-way thermostatic mixing valve Copyright Caleffi Installation, commissioning and servicing instructions Series Function The Caleffi MixCal three-way thermostatic
More information80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features
Comfort Module Range for Monobloc Heat Pumps Quality Management Systems Comfort module with two-zone kit Single-zone comfort module 8HMA Nominal heating capacity 4- kw Nominal cooling capacity 4- kw The
More informationInstallation, Operating and Servicing Instructions
EN 0 / 0 / 00 / 800 Installation, Operating and Servicing Instructions excellence in hot water EN Y000.D EN INDEX Warnings Who should read these instructions Symbols Recommendations Applicable standards
More informationCONTROL UNIT FOR UNDERFLOOR HEATING SYSTEMS
ST.04.04.00 ONTROL UNIT FOR UNERFLOOR HETING SYSTEMS Low temperature control unit Low+high temperature control unit 1. ONTROL UNIT PPLITION The FR control unit is suitable for systems combining both high
More informationTR 0603mc U Solar Controller
TR 0603mc U Solar Controller Part #8718572810 Engineering Submittal Sheet 178 mm [7.00 inch] 8 90 mm [3.54 inch] 170 mm [6.69 inch] 170 mm [6.69 inch] 134 mm [5.28 inch] 106 mm [4.17 inch] 32 1.26 0.31
More informationWe regulate and supply clean energy
Bonetti Rubinetterie Valduggia S.r.l. Language English Home The Company News Contacts Download International M2 MIX33 - DN32 We regulate and supply clean energy 2-Way pump unit with 3-way mixing valve
More informationBrazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)
Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 The XB is a brazed plate heat exchanger designed for use with district heating systems (i.e. air conditioning,
More informationAdjustable three-way thermostatic mixing valve... connections ½", ¾", 1" NPT male union and sweat union and ¾" press
MixCal djustable three-way thermostatic mixing valve series CCRIT ISO 9 FM ISO 9 No. CLFFI / N Replaces / N Function The Caleffi MixCal series three-way thermostatic mixing valve is used in systems producing
More informationTechnical Data Manual
VITOTRONIC 300 Weather-responsive indoor/outdoor, digital boiler control for heating systems with one or more heating circuits Technical Data Manual Vitotronic 300 Model KW3, Part No. Z001 231 For operation
More informationIDEAL LOGIC HEAT INTERFACE UNITS (HIUs) PRODUCT GUIDE.
IDEAL LOGIC HEAT INTERFACE UNITS (HIUs) RODUCT GUIDE. IDEALCOMMERCIALBOILERS.COM IDEAL COMMERCIAL HEATING SOLUTIONS. Ideal Commercial Boilers is one of the most respected names in the UK commercial and
More informationThe ECL Comfort 110 is a universal 1-circuit controller for use in district heating substations and district heating systems as well as boilerbased
Data sheet ECL Comfort 110 230 V a.c. and 24 V a.c. Description and application ECL Comfort 110 The ECL Comfort 110 is a universal 1-circuit controller for use in district heating substations and district
More informationAir handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses
REC Temovex 4S-EC-RS Experts on indoor climate in low-energy houses RT 4S-EC-RS REC Temovex 4S-EC-RS ECO2 control system for low-energy and passive houses Comprises: - Air flow boost for warm and cold
More informationFHM-Cx Mixing Shunts for Floor Heating
FHM-Cx Mixing Shunts for Floor Heating Application Mixing shunt FHM-C5/C6 (UPS pump) The Danfoss compact mixing shunts are used for regulation of flow and supply temperature in hydronic floor heating systems.
More informationSATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production
SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production SATK0 - SATK0 series ACCREDITED ISO 900 FM 009/ GB replaces dp 009/ GB Function The latest generation of Heat Interface
More informationsustainable energy solutions
sustainable energy solutions EN Why Laddomat? 6 7 Laddomat 21-series 8 9 Laddomat 11-series NEW! 10 11 Laddomat 11 Duo NEW! 12 Laddomat 11-30 FDV 13 Laddomatic NEW! 14-15 Laddomat M120 16 Laddotank NEW!
More informationLOVATO T-FIRE MODUL T-FIRE MODUL L TRENNSYSTEM / SEPARATION UNIT HOLZKESSELS PELLETS BOILER PELLETKESSEL WOOD BOILER DESCRIPTION ADVANTAGES
TRENNSYSTEM / SEPARATION UNIT LOVATO T-FIRE MODUL T-FIRE MODUL PELLETKESSEL WOOD BOILER T-FIRE MODUL L HOLZKESSELS PELLETS BOILER Wasser des Kamins die geeignete Temperatur erreicht hat. DESCRIPTION for
More informationInstallation, Operating and Servicing Instructions
ENGLISH 0 / 0 / 0 / 0 / 00 Installation, Operating and Servicing Instructions FRANCAIS NEDERLANDS ESPAÑOL Y000.A EN ESPAÑOL NEDERLANDS FRANCAIS ENGLISH INDEX WARNING Who should read these instructions
More information5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341
NA31 www.caleffi.com Low Lead High Flow Thermostatic Mixing Valves Copyright 1 Caleffi Installation, commissioning and service instructions Function 531 Series ASSE 17 model 531 series high flow thermostatic
More informationSOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS
SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS INDEX Ed. 20150422 GENERAL INFORMATION... 2 Before installing... 2 Materials and PED (97/23/CE) Standards... 3 SKID-TYPE DISTRICT HEATING
More informationunion swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve
VENT APPENDIX A: PIPING SYMBOL LEGEND GENERIC COMPONENTS CALEFFI COMPONENTS circulator circulator w/ ThermoBloc union circulator w/ swing check spring loaded balancing balancing w/ gate check globe s purging
More information24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.
24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers Enerwa / EnerwaPlus www.warmhaus.com Condensing-ErP Premix System Boilers 24/31-28/35-33/40 kw Warmhaus wall-hung gas combi boilers
More informationConstant climate chambers
Constant climate chambers KBF P 240 (E2) - Constant climate chamber for photostability tests Specialized equipment for photostability tests. Integrated cooling of fans consistently compensates for the
More informationThermostatic mixing valves with replaceable cartridge for centralized systems
Thermostatic mixing valves with replaceable cartridge for centralized systems series REGISTERED BS EN ISO 9: Cert. n FM UNI EN ISO 9: Cert. n / N Replaces /9 N Function The thermostatic mixing valve is
More informationGHP AWO 38 Technical overview
Gas absorption heat pump 9 Technical overview single unit G&' &(')*ption heat pump components. 1 7 2 8 9 3 4 10 8 5 6 1 +),-.&/012 &0* ')-*34 5&1 2 G414*&/)* 3 G&' (-*ner 4 6)1,41'4* 5 6)7(-'/0)1 38&7(4*
More informationCALEFFI. Anti-condensation recirculation and distribution unit. 281 series 01224/14 GB. Replaces dp 01224/12 GB. Function
Anti-condensation recirculation and distribution unit 8 series ACCREDITED ISO 900 FM 654 ISO 900 No. 000 CALEFFI 04/4 GB Replaces dp 04/ GB GB Function The anti-condensation recirculation and distribution
More informationEW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS
Design Hydronic meters of the EW447-452 Series consist of: Electronic energy integrator with fixed cable connection to the volume measuring component, supply and return temperature probe Mechanical volume
More informationSweden s leading air source heat pump
- Since 1939 ExoAir / ExoAir Polaris GreenEnergy Sweden s leading air source heat pump BEST IN TEST The Swedish Energy Council recently scored the Euronom air source heat pump as the leading product of
More informationAuto Technology Company Cyclic Corrosion Test Chamber
Auto Technology Company Cyclic Corrosion Test Chamber Built for Versatile and Repeatable Testing The Auto Technology Cyclic Corrosion Test (CCT) Chamber creates a variety of environments in an exposure
More informationValves, controls + systems. Regucor WHS Energy storage centre. Innovation + Quality. Product range. v o. Awards: i y. n n
Valves, controls + systems Innovation + Quality Energy storage centre Product range ed v o r p m i y c n n for a y efficie g ener Awards: Energy storage centre Heating systems with regenerative energy
More informationAutomatic Temperature Controller (ATC)
NEW FROM APOLLO...THE FIRST MULTIPLE-FIXTURE HI-LO MIXING VALVE THAT MEETS ASSE 1017 AND THE NEW ASSE 1069 STANDARD Only Apollo offers fast delivery on the first water temperature mixing assembly to meet
More informationThe Ultimate Solution for Electric Central Heating. Fusion. Comet
The Ultimate Solution for Electric Central Heating Fusion Comet Our range of Electric Boilers provide complete peace of mind for reliability, performance and safety 2 The Fusion range of electric boilers
More informationCATALOGUE THERMAL CONTROL MADE SIMPLE
CATALOGUE 2016 THERAL CONTROL ADE SIPLE DEAR SOREL-CUSTOER 25 years ago, back in January 1991, I founded SOREL to help saving finite resources by intelligent thermal controls for heating applications.
More informationECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys
ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark Description ECL Comfort 210 controller series ECL 210 The ECL Comfort 210 is an electronic weather
More information1 DOCUMENT REVISION CONTROL ELEMENTS... 9
CONTENTS Contents 1 DOCUMENT REVISION... 8 2 SOFTWARE VERSION... 8 3 BASIC DESCRIPTION... 8 4 CONTROL ELEMENTS... 9 4.1 BASIC DISPLAYS...10 4.2 CONTROL KEYS...11 4.2.1 Rotary button (Press / Turn)...11
More informationConstant climate chambers
KBF series (E5.2) Constant climate chambers Constant climate chambers The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climatic conditions.
More informationAPPLICATIONS. For the accelerated circulation of hot water in heating circuits with duty point optimisation
OPERATING RANGE Flow rate of up to m /h Manometric head of up to m Max. operating pressure bar Min. intake pressure, bar at 9 C Water temperature range + at + C * EEI-Part, * for a ambient temperature
More informationSOLARCOMP 951 CONTROLLER FOR SOLAR COLLECTORS
SOLARCOMP 951 CONTROLLER FOR SOLAR COLLECTORS Installation and Operating Instructions for model u7.x, Rev. 1, April 2014 Pb Safety Instructions Before installation read these Operation and Installation
More informationSystem controller for cascade control, heating boilers with solar, buffer and pel et control
E8.5064 System controller for cascade control, heating boilers with solar, buffer and pellet control Modulating cascade controller with solar control Switching cascade controller with solar control Modulating
More informationTaco 00 Series Cartridge Circulators
Water Circulation Pumps & Circulators Taco 00 Series Cartridge Circulators For over 70 years, Taco has led the industry with the highest quality circulators you can buy. Designed for a wide range of residential
More informationData Sheet. Compact Mixing Shunt for Floor Heating, FHM-Cx. Application:
Data Sheet Compact Mixing Shunt for Floor Heating, FHM-Cx Application: FHM-C1 Mixing shunt FHM-C/ FHM-C Mixing shunt FHM-C Mixing shunt FHM-C The Danfoss floor heating compact mixing shunts are used for
More informationSPECIFICATIONS - NIKE
Wall-mounted instant boilers NIKE Mini kw Special is the ideal Immergas solution for modern building and wherever space is limited and has to be made the most of. Simple to use and easy to install, thanks
More information