1 HyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1 INSTALLATION, COMMISSIONING AND OPERATING INSTRUCTIONS Contents Unit as delivered Contents...1 Safety Guidelines...2 General Warnings...2 Before Installation...2 Wiring...2 Description...2 Dimensions and details...3 Hydraulic diagram...3 Technical data...3 Mounting...4 External casing dismounting-mounting...4 Wall mounting...4 Fixing electrical cables...5 Electrical connections...5 Activation...5 Display and keypad...5 Programming for Technician...6 Deactivation of unit functions...6 Unit electrical disconnection...6 Control and regulations...6 DHW temperature...6 Spare parts...7 Metering...7 Backflow preventer...7 Unit Components Rev. B Unit completed with optional components Honeywell Subject to change EN1H-2615GE25 R0914

2 Safety Guidelines General Warnings Honeywell Hydraulic Interface Unit must be installed by qualified personnel in accordance with the applicable regulations and IEE Regulations. The end user is not authorized to work on the unit. Any contractual or extra-contractual responsibilities of the Constructor is excluded for damages to people, animals or things caused by an improper use or by installation mistakes or special maintenance as well as by not qualified personnel intervention and, in general, by non-fulfilment of what indicated in installation, commissioning and operating instructions. Honeywell take no responsibility for difficulties arising from failure to observe these instructions. Please read this manual before undertaking the installation. Upon completion of the installation, please hand these instructions to the user. These instructions should be retained for future reference. Honeywell EHIU1 is a wall hanging HIU with optional external casing. If installed without external casing it must be placed in a protected space not accessible by unqualified people. It has the capability to provide the central heating and to produce instantaneous domestic hot water. Hot water is always produced in priority to the heating service. The maximum temperature of the domestic hot water may be adjusted by accessing the digital display unit which is positioned within the casing. Risk of scalding! Even in normal operating conditions unit reaches high temperatures that can cause burns. It is risky to touch the pipes without protection. Risk of electric shock or equipment damage! Before installation and any maintenance operation disconnect electrical supply. For device disconnection use a circuit breaker or a plug. Do not reconnect the power supply until you have completed the installation. In general before any operation disconnect power supply. Device doesn t requires any maintenance. If installation instructions are followed, required water quality is provided and installed space is controlled. After 6 month of usage it is recommended just to clean the strainer. Before Installation 1. Unpack and remove the EHIU1 from carton. 2. Check the equipment and report any damage to a Honeywell representative. 3. The unit must be fixed to the wall by using no. 4 Ø 8 mm anchors (not included). NOTE: Anchoring materials must be suitable for the mounting surface which must comply with all local codes. Wiring The Installer has to check that unit fixing systems are suitable to mounting wall. This equipment must only be used for the purpose for which it was intended, improper use may be hazardous. M-Bus and electrical supply cables must be separated in order to avoid any interferences. All electrical connection must be compliant with local laws, rules and regulations. A suitable room thermostat clock/room thermostat with 230V 50 Hz output must be provided and connected by the installer. The electronic board is protected by a 1 Ampere fuse. The unit needs a 230V 50Hz electrical connection. If the unit is installed inside the apartment, power supply must be sourced from the apartment itself. On the contrary, if the unit is installed in common locals, it is supplied by a common central line. Description Notices about domestic hot water If the supply water hardness exceeds 15 f (dgh) it is recommended to install a suitable scale reducing device (softener). In order to reduce scale forming inside heat exchanger, set the sanitary water temperature to a value that is slightly superior compared to the operating one. ph value should be between 7 ~ 9. EN1H-2615GE25 R Honeywell Subject to change

3 Dimensions and details Technical data 1. Room thermostat 230V AC 2. Power supply 230V AC Hydraulic diagram 1 Manual isolation valve 2 Plate heat exchanger 3 Manual air vent 4 Modulating motorized valve for DHW control 5 Static balancing valve 6 DHW sensor 7 On/Off motorized valve for heating control 8 DHW flow sensor 9 Filter 10 Pressure control probe holder 11 Blind pipe for water meter 12 Heat meter temperature probe holder 13 Blind pipe for water meter 14 Control panel A B C D E F G Return to centralized system Supply from centralized system Cold sanitary water inlet Hot sanitary water outlet Cold sanitary water outlet Heating outlet to apartement Heating return from apartement Heating Circuit Kind of fluid Water VDI2035 max. glycol 30% Max. temperature 90 C Max. operating pressure 6 bar Domestic water line Kind of fluid Water max hardness 15dGH and ph 7-9 Max.temperature 30 C Max. operating pressure 6 bar Max. flow rate 1.5 m 3 /h Nominal flow rate 1.25 m 3 /h DHW / Exchanger Secondary Circuit Kind of fluid Water max hardness 15dGH and ph 7-9 Max. setting temperature 60 C Max. operating pressure 6 bar DHW production flow activation 3.5 l/min DHW production flow 2.5 l/min deactivation Display approximation 1 C Max. flow rate 22l/min* Pipes Material Copper Size 18 mm Hydraulic connections Material Brass Size G 3/4" M Template box Material Galvanized sheet 1 mm Casing and door Material pickling sheet 1 mm Colour RAL 9010 Electrical supply Voltage 230V +/- 10% Frequency 50 Hz Max. power consumption 10W IP protection 20 Ambient operation Installation Indoor Ambient temperature range 5-55 C Humidity range 25-85% Motorized Valve Operation time ON/OFF type 15 sec Operation time Modulating type 15 sec * Physical limit for quite operation. Real max flow depends on target system parameters. Honeywell Subject to change 3 EN1H-2615GE25 R0914

4 The figures/table below indicates k v values of the unit. Mounting External casing dismounting-mounting Before installation the external casing must be removed as indicated in the image. The external casing is a unique piece placed on the carrying structure: it is fixed by 2 screws on superior part and 2 screws on inferior part. After external casing removal and having placed it safely, it is possible to proceed with the hydraulic unit installation. k v (m 3 /h with Δp = 100 kpa = 1 bar) Circuit Heat exchanger type 24P 40P no meter no meter A-B primary heat 1.76mc/h 1.88mc/h exchanger Circuit Balancing type Static DPCV no meter no meter (B-F) + (G-A) heating 2.68 mc/h 2.18 mc/h Circuit C-D hot water C-E cold water 1.83 mc/h 5.06 mc/h *k vs values refer to the static balancing valve setted at 5.9 (pre-setting) and at 1.5 for the DPCV The general equation for calculating pressure drop, knowing flow rate value is the following Δp [bar] = (Q [m 3 /h] / k v) 2 The indicated k v are valid for water without glycol. Wall mounting The unit has to be installed indoors in suitable ambient conditions (see technical specification on page 3). The installer has to individuate the most suitable wall according to weight and overall dimensions indicated on page 3. For fixing unit it is necessary to use no. 4 Ø 8 mm anchors (not included), they have to be suitable to the chosen wall for installation. The position has to be compliant with hydraulic connections. It is suggested to leave a free space of 10cm on left side for an easier access to the strainer Before installing the unit, the centralised and apartment systems must be cleansed and flushed to avoid fouling of the unit with impurities or debris from the pipe work installation procedures. The presence of impurities in pipes can be the reason for unsatisfactory working and can cause possible damages to unit components. Therefore it is very important to carefully flush pipes before installing. Connecting the unit to centralized distribution system with interception manual valves (included) is strongly recommended. Thanks to this the unit could be quickly and without particular user unease de-touched from centralized plant in case of special maintenance. Take care not to damage or break the connection seals. Pipe connection torque must not exceed 50 Nm. EN1H-2615GE25 R Honeywell Subject to change

5 Fixing electrical cables Power electrical and ambient thermostat cables enter the unit thanks to cable glands on unit bottom side. Cable maximum diameter: 8 mm. Cable terminals must be connected to related board inside the electrical box ( see electrical connections ). Between cable glands and electrical box, cables must be positioned in a way that avoids contact with copper pipes. Please use the specific cable glands supplied. Electrical connections Before carrying out electrical connections, please read general instructions at page 1. Isolate the unit from the electrical supply before removing the cover of the electrical box. THIS APPLIANCE MUST BE GROUNDED. Ground wire connection must be secured against releasing. The electrical installation must only carried out by competent persons in accordance with the current edition of the IEE regulations. Activation Once the installation is completed and after checking that all electric and hydraulic connections have been correctly made, it is possible to activate the unit by moving the bipolar switch on electric box to ON position. Display and keypad The LED lights on the right side of the digital display indicate the actions of the hot water temperature control system. Red LED = Valve opening/open - the temperature of the hot water is required to be raised Green LED = Valve closing/closed - the temperature of the hot water is required to be reduced In order to turn it off, press the ON/OFF button: if the equipment is still powered, the OFF sign will appear. When the unit is electrically powered,the installed software version is shown on the display for a few seconds. Immediately after, if the equipment was off the last time it was powered (default condition at the time of purchase),the OFF message appears. In order to turn it on, press the D -ON/OFF button once. The display shows the temperature detected by the sensor which is placed at the outlet of the domestic hot water delivered to the dwelling. When a hot water tap is opened, the unit will start automatically. Supply Cable (L- - N) 3 x 1.5 mm 2 cable heat resistance; line, neutral, blue sheathing ground, yellow/green sheathing Room thermostat (T.A) 2 x 1.5 mm 2 cable heat resistance. This device must give power to TA terminal ends in order to power relay coil positioned inside the electric board. Working logic: 230V TA ends voltage: heating function activation (opened valve) 0V TA ends voltage: heating function deactivation (closed valve) 1. Fuse 2. Bipolar switch 3. Cable gland Honeywell Subject to change 5 EN1H-2615GE25 R0914

6 Programming for Technician Access to programming menu. When digital display shows OFF, push simultaneously A and B buttons. When display shows P1 release buttons. A and B buttons scroll main menu and increase or decrease value in under menu. ENTER button goes into sub menu and save data itself. Main menu Under menu Function P1 X.X (sec) Where X.X indicates time of sampling temperature. Regulation range 1.0 ³ 10.0 sec (default 1.0 sec) for 24 plates heat exchanger and 1.3 sec for 40 plates heat exchanger P2 X (sec) Where X indicates delay time ordered to activation of sanitary hot water production by flow meter signal (eco function) Regulation range: 0 ³ 5 sec. (default 0 sec) P3 XX ( C) Where XX indicates the Δ temperature to be added to the setpoint to obtain the maximum permitted temperature beyond which the sanitary valve closes. Anti-burns function*. Regulation range 5 ³ 50 C (default 5 C) P4 XX (sec) Where XX indicates delay time ordered to anti burns function intervention. Regulation range 0 30 sec (default 0 sec) P5 X Where X is a Boolean variable that can be: 0 = warmed heat exchanger function activated ** 1 = warmed heat exchanger function deactivated (default 1) (*) Anti-burns function intervenes when the sensor, positioned on hot sanitary water delivery, feels a temperature superior to set-point + P3 value. In this condition the modulating 2-way valve, positioned on heat exchanger primary, is forced to complete closure and interrupts the erogation of thermal energy. When temperature goes down to set-point + P3 value, the system automatically starts normal production of sanitary hot water again. (**) When warmed heat exchanger function is activated (P5 =0) the primary circuit of the heat exchanger is constantly maintained in temperature (even in absence of sanitary drawing) thanks to the passage of a small quantity of hot water in primary circuit. This function can be activated when the unit is away from distribution columns to reduce the DHW production delay time. The anti-burns function helps to avoid supply of hot sanitary water with dangerous temperatures. Installing devices for thermal safety for sanitary uses to be placed below the unit is advised. If the hot sanitary water temperature sensor is damaged or not connected the display shows the allarm ALt. The modulating valve of the plated exchanger primary circuit is forced to closing; the flashing "AL t" is displayed. When the damage is restored the unit start again with its normal functioning. Deactivation of unit functions During summer time, in order to deactivate heating function you have to set the minimum temperature value on room thermostat or selecting OFF mode, if present. Regarding sanitary function, excluding all takings is sufficient and the module will automatically stop any energy inflow from centralized plant (if the warmed heat exchanger is deactivated). Besides, pressing ON/OFF button on keypad is possible to deactivate hydraulic unit functions. On display you find OFF and all functions are deactivated:both motorized valves are on complete closing Unit electrical disconnection To disconnect the unit from electrical network follow these instructions: 1. Electrically disconnect ambient thermostat 2. Press ON/OFF button on keypad 3. Wait for about 30 sec. in order to give time to motorized valves to close. 4. Check that the motorized valves are in closed position by checking directional arrow position 5. Move the bi-polar switch on electrical box to OFF position Electrical power coming from ambient thermostat is NOT interrupted by bi-polar switch. In order to complete disconnect the hydraulic unit form electrical power interrupt ambient thermostat power. A disconnection from electric network made without operating as described above does not grant the complete hydraulic isolation of the module from the whole plant. As a consequence the module could still take and regulate heat even though not requested. Control and regulations DHW temperature When the unit is activated and the display shows the temperature detected by the probe, it is possible to adjust the set supply temperature of the hot sanitary water. Use the buttons on the keypad: Press the A button to decrease the temperature value. Press the B button to increase the temperature value. The display will show a value ranging from 0 to corresponds to approximately 40 C, 10 corresponds to approximately 60 C. Then, press ENTER to accept the value. EN1H-2615GE25 R Honeywell Subject to change

7 Balancing The unit is equipped with a static balancing valve. In addition can be added the diaphragm for differential pressure balancing (not included with HIU). A probe is already installed on pipe "f" to facilitate the installation. See in picture below the suggest installation. Metering The unit can be equipped with energy and water meters. Stub pieces are arranged on the unit to facilitate the installation: remove the stub piece install the meter (max torque 50Nm) - original sealings installed with stub pieces must be replaced - When installing display of ultrasonic heatmeter take care to use not too long screws to avoid touching the pipe under connect temperature sensors in the pre-arranged probes Heatmeter 1 will measure the total energy consumtpion both for heating and domestic hot water production. Heatmeter 2 will measure the energy consumption of apartment heating only. Energy consumption only for domestic hot water production can be measured as difference between heatmeter 1 and heatmeter 2. Sharp edges could cause injury. The Heat meter should be installed before the impulse copper tube of diaphragm unit for dynamic balancing. Don't bend the tube to the sharp angles - it may cause breaks. Before installation of any meter take out the old washer, clean the sealing surface and use new washer (not included). Backflow preventer As required by regulations insert a backflow preventer on the domestic cold water inlet. Backflow preventer is not included with the unit. Unit Components Heat exchanger (insulated) Strainer (behind heat exchanger) Flow meter Air valves Electronic controller Heatmeter 2 temperature probe Static balancing valve (pipe probe for upgrade to automatic) Temperature sensor for sanitary water ON/OFF motorized valve Modulating motorized valve Place for heatmeter 1 Pipes (insulated) Place for water meter Support for ultrasonic heatmeters Heatmeter 1 temperature probe Place for heatmeter 2 Passage for electric connections Cabinet with door Stop valves a b c d e f g Honeywell Subject to change 7 EN1H-2615GE25 R0914

8 Environmental and Combustion Controls Honeywell GmbH Hardhofweg MOSBACH GERMANY Phone: +49 (6261) 810 Fax: +49 (6261) Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Z.A. La Pièce 16, 1180 Rolle, Switzerland or its Authorized Representative. EN1H-2615GE25 R0914 Subject to change without notice 2014 Honeywell International Inc.

Metering Box METERING AND AMBIENT HEATING FOR HEATING SYSTEM. Overview. Application PRODUCT DATA

Metering Box METERING AND AMBIENT HEATING FOR HEATING SYSTEM. Overview. Application PRODUCT DATA Metering Box METERING AND AMBIENT HEATING FOR HEATING SYSTEM Overview PRODUCT DATA The Honeywell Substations series consist of the following products: Metering Box (this datasheet) Heat Interface Unit,

More information

SATK50-60 series CONTENTS. Recess Mounted Heat Interface Unit - SATK series INSTRUCTIONS FOR INSTALLATION, COMMISSIONING AND MAINTENANCE

SATK50-60 series CONTENTS. Recess Mounted Heat Interface Unit - SATK series INSTRUCTIONS FOR INSTALLATION, COMMISSIONING AND MAINTENANCE 780EN www.caleffi.com Recess Mounted Heat Interface Unit - SATK series SATK0-60 series INSTRUCTIS FOR INSTALLATI, COMMISSIING AND MAINTENANCE Function The SATK series HIU allows independent control of

More information

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production SATK0 - SATK0 series ACCREDITED ISO 900 FM 009/ GB replaces dp 009/ GB Function The latest generation of Heat Interface

More information

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB 4 RESET ON DHW CH FAULT SATK wall-mounted heat interface unit Fitted for connection to DHW storage SATK4 series ACCREDITED CALEFFI 6/4 GB ISO 9 FM 64 ISO 9 No. The latest generation of heat interface units

More information

PrimusCenter DWC7000. Domestic Water Centre. Product specification sheet

PrimusCenter DWC7000. Domestic Water Centre. Product specification sheet PrimusCenter DWC7000 Domestic Water Centre Product specification sheet Construction The domestic water centre consists of: R1 filter connection fitting with backflow preventer FK7000 filter combination

More information

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS W GE R MAN Y W GE R MAN Y V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS Design Angle left Straight W GE R MAN Y Angle right The Therafix

More information

Metering systems 0548EN April 2014

Metering systems 0548EN April 2014 08EN April 0 0U8 GEY - Y - Y (GE- series) 900 000/ 00 00A/ 800 00L/ Versions and product codes Product code Type Heat exchanger nominal power GEY, - GEY and production GEY and production Table - Product

More information

Wall-mounted compact indirect heat interface unit SATK30 series Safety instructions Dimensions Technical specifications Installation Commissioning

Wall-mounted compact indirect heat interface unit SATK30 series Safety instructions Dimensions Technical specifications Installation Commissioning 78.0EN www.caleffi.com Wall-mounted compact indirect heat interface unit SATK0 series INSTRUCTIS FOR INSTALLATI, COMMISSIING AND MAINTENANCE Function The SATK series HIU allows independent control of heat

More information

INSTALLATION AND SERVICING

INSTALLATION AND SERVICING INSTALLATION AND SERVICING LOGIC HIU (Heat Interface Unit) Indirect 75 Indirect 50 Direct MT Direct HT When replacing any part on this appliance, use only spare parts that you can be assured conform to

More information

Herz York Direct Heat Interface Unit

Herz York Direct Heat Interface Unit www.herzvalves.com Herz York Direct Heat Interface Unit The Modern Solution for Apartment Heating and Domestic Hot Water Services General Description The Herz York Direct HIU is suitable for all community

More information

EW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS

EW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS Design Hydronic meters of the EW447-452 Series consist of: Electronic energy integrator with fixed cable connection to the volume measuring component, supply and return temperature probe Mechanical volume

More information

TIREE FAN COIL CONTROLLER - T6580

TIREE FAN COIL CONTROLLER - T6580 TIREE FAN COIL CONTROLLER - T6580 PRODUCT SPECIFICATION SHEET 20 DESCRIPTION A pleasing and modern appearance makes the TIREE ideal for living quarter applications, in particular offices and hotels. In

More information

HTD. High Temperature Non-Cycling Refrigerated Compressed Air Dryers. Operation & Maintenance Manual. MODELS HTD 21 thru HTD 100

HTD. High Temperature Non-Cycling Refrigerated Compressed Air Dryers. Operation & Maintenance Manual. MODELS HTD 21 thru HTD 100 HTD High Temperature Non-Cycling Refrigerated Compressed Air Dryers Operation & Maintenance Manual MODELS HTD 21 thru HTD 100 - TABLE OF CONTENTS - 1.0 GENERAL 2 1.1 How to use this manual 1.2 Symbols

More information

T6580 FAN COIL CONTROLLER

T6580 FAN COIL CONTROLLER 20 DESCRIPTION A pleasing and modern appearance makes the T6580 ideal for living quarter applications, in particular offices and hotels. In all versions, the control is Proportional + Integral (P+I). This

More information

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS TSEK VENCO Havalandırma ve Makina San.ve Tic. A.Ş. 2004. Cad. No:5 45400 OSB Turgutlu MANISA / TURKİYE Tel: +90 (236) 332

More information

HEAT INTERFACE UNITS (Sanitary Hot Water Only)

HEAT INTERFACE UNITS (Sanitary Hot Water Only) HEAT INTERFACE UNITS (Sanitary Hot Water Only) T-FAST i20 (Sanitary Hot Water Only) 20 The T-Fast i20 is an instantaneous domestic hot water production module that produces a flow rate of 20L per/min at

More information

DT90 DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

DT90 DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET DT90 DIGITAL ROOM THERMOSTAT PRODUCT SPECIFICATION SHEET The new DT90 family of digital room thermostats is a range of market leading products designed to provide comfort with economy in modern heating

More information

NIKE Star 24 3 E. Instantaneous wall-hung with open chamber boilers. NIKE Star 24 3 E

NIKE Star 24 3 E. Instantaneous wall-hung with open chamber boilers. NIKE Star 24 3 E Instantaneous wall-hung with open chamber boilers Small wall-mounted open chamber, conventional flue instant boiler. General features. is a wall-mounted, open combustion chamber, conventional flue generator

More information

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet CBU144 Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717 Product specification sheet Version The Compact Booster Unit consists of the following modules, that

More information

Installation and Operation Instructions Domestic hot water module FriwaMini with circulation - DN 15

Installation and Operation Instructions Domestic hot water module FriwaMini with circulation - DN 15 PAW GmbH & Co.KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: info@paw.eu, Web: www.paw.eu Installation and Operation Instructions Domestic hot water module

More information

1 VICTRIX ZEUS Superior kw I features

1 VICTRIX ZEUS Superior kw I features Wall-hung condensing VICTRIX ZEUS Superior kw I is the new range of wall-hung condensing boilers with 54 litre stainless steel storage tank available in two versions with nominal heat output of 26 kw and

More information

PROGRAMMABLE 7-DAY RF THERMOSTAT

PROGRAMMABLE 7-DAY RF THERMOSTAT PROGRAMMABLE 7-DAY RF THERMOSTAT Installation and user instruction This instructions to be retained by the user 1 Thank you for choosing Beretta s radio frequency (RF) Radiostat. This central heating control

More information

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS LCB-I-O Rev B MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS Models: KB 81-286, KBXL 400-801, WB 51-211, and WH 55-399 IMG00116 WARNING This manual must only be used by a qualified heating installer

More information

ELECTRIC BOILERS FOR CENTRAL HEATING

ELECTRIC BOILERS FOR CENTRAL HEATING ELECTRIC BOILERS FOR CENTRAL HEATING TermoMax INSTRUCTIONS FOR INSTALLATION INSTRUCTIONS FOR INSTALLATION We reserve the right of alternations WE ARE NOT LIABLE FOR DAMAGES RESULTING FROM NON- OBSERVING

More information

User manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort

User manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort User manual CLIMATIC 2/4 - Controller Providing indoor climate comfort MUL35E-56 9-26 INDEX CONTENTS PAGE INDEX 1 GENERAL DESCRIPTION 2 THE KEYPAD, Climatic 2 3 THE KEYPAD, Climatic 4 4 THE KEYPAD REMOTE

More information

SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS

SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS INDEX Ed. 20150422 GENERAL INFORMATION... 2 Before installing... 2 Materials and PED (97/23/CE) Standards... 3 SKID-TYPE DISTRICT HEATING

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING

More information

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services TA-COMFORT-S Prefabricated units Heating interface unit for surface heating and hot water services IMI TA / Control valves / TA-COMFORT-S TA-COMFORT-S All in one design with STAP differential pressure

More information

INSTRUCTION FOR THE USER THC V E OIL BLU

INSTRUCTION FOR THE USER THC V E OIL BLU INSTRUCTION FOR THE THC V E OIL BLU CONTENTS General safety information 4 Precautions 4 Control panel 5 Mode selection 8 User levels 10 Start-up 12 Temporary shutdown 15 Preparing for extended periods

More information

Janfire Pellet Burner Boiler. for single / double burner management (Version 1.1)

Janfire Pellet Burner Boiler. for single / double burner management (Version 1.1) SY325 Janfire Pellet Burner Boiler for single / double burner management (Version 1.1) TECHNICAL DATA SHEET V1.1 rev.12/2007 Contents INTRODUCTION...3 1 THE CONTROL PANEL...4 2 THE KEYS...4 3 THE LEDS...4

More information

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS LCB-I-O Rev D MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS Models: KB 81-286, KBXL 400-801, WB 51-211, FTX 400-850 and WH 55-399 WARNING This manual must only be used by a qualified heating installer

More information

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve Connection and energy management compact unit 2850 series ACCREDITED CALEFFI 01259/14 GB ISO 9001 FM 21654 ISO 9001 No. 0003 Function The connection and energy management compact unit enables combining

More information

Refrigerated air dryers

Refrigerated air dryers Refrigerated air dryers OPERATING AND MAINTENANCE MANUAL Original instructions 38178800319 OPERATING AND MAINTENANCE MANUAL - Contents 1 CONTENTS CONTENTS... 1 Chapter 1 IDRY ELECTRONIC CONTROLLER...

More information

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION ECO-FRIENDLY REFRIGERANT GAS INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the result of many years

More information

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production THE SIMPLEST SOLUTION FOR A CONDENSING BOILER DIVACONDENS D PLUS is the generator of condensation

More information

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Data sheet Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 IHPT The XB is a brazed plate heat exchanger designed for use with district heating systems

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -

More information

District heating controller for two heating circuits and d.h.w. according to Siemens specifications:

District heating controller for two heating circuits and d.h.w. according to Siemens specifications: 4 319 2984 0 G2384en en Installation Instructions District heating controller for two heating circuits and d.h.w. RVD240 Installation Place of installation In a dry room, e.g. in the heat exchanger room

More information

Installation, operating and servicing instructions

Installation, operating and servicing instructions English 57-115 - 144-1 - 259 Installation, operating and servicing instructions ITALIA EN 1 ITALIA English INDEX WARnINGS 3 Who should read these instructions 3 Symbols 3 Recommendations 3 Importants notes

More information

UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2. Version: 2018_07_19_v2.2

UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2. Version: 2018_07_19_v2.2 UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2 Version: 2018_07_19_v2.2 Abstract This is a quick reference guide for selecting the UniQ range of heat batteries for the required application. For designing a

More information

CRIMSON & CRIMSON MAX

CRIMSON & CRIMSON MAX High efficiency water/water and geothermal heat pumps 5 114 General High efficiency water/water and geothermal heat pumps. Ideal for heating, cooling and production of domestic hotwater with total or partial

More information

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Data sheet Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 IHPT The XB is a brazed plate heat exchanger designed for use with district heating systems

More information

Trade Product List 2013 BIOMASS ACCESSORIES

Trade Product List 2013 BIOMASS ACCESSORIES Trade Product List 2013 BIOMASS ACCESSORIES BIOMASS SYSTEM COMPONENTS Constant Temperature Control Accessories CONSTANT TEMPERATURE CONTROL PRODUCTS Order Code Description of Package and Contents Pictures

More information

PCR-300 PCR-300 RC. Installation and Operating Instructions

PCR-300 PCR-300 RC. Installation and Operating Instructions PCR-300 PCR-300 RC Installation and Operating Instructions Electronic refrigeration control EB-PCR-04 EN1H-1924GE23 R1207 TABLE OF CONTENTS 11 Unpacking the unit and conditions of use 3 12 General instructions

More information

03.03.mmm REV.2 09/01

03.03.mmm REV.2 09/01 03.03.mmm REV.2 09/01 Via del Lavoro, 80-40056 CRESPELLANO (Bologna) ITALY - ( +39 051/733.383 - Fax. +39 051/733.620 P.O. BOX, 150-40011 ANZOLA EMILIA (Bologna) - ITALY Power Factor Regulator cosφ V A

More information

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 The XB is a brazed plate heat exchanger designed for use with district heating systems (i.e. air conditioning,

More information

heat interface units A BOILER WITHOUT A FLAME

heat interface units A BOILER WITHOUT A FLAME A BOILER WITHOUT A FLAME heat interface units Communal Heat Networks A central boiler house will generate heat which is distributed through a network of pipe to each home or apartment in the building.

More information

Installation manual W365H, W375H, W3105H, W3130H, W3180H, W3240H, W3300H Exacta & Clarus Control

Installation manual W365H, W375H, W3105H, W3130H, W3180H, W3240H, W3300H Exacta & Clarus Control manual W365H, W375H, W305H, W330H, W380H, W3240H, W3300H Exacta & Clarus Control 438 9200-0 06.34 Contents 3 Contents Technical data... :... 2: Transportation and unpacking... 2: Siting and floor... 3:

More information

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING Manual Contents Introduction...3 Valve compatibility...3 Features...3 Application examples...3 Ordering...3 Operating the EKC 347...4-5

More information

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER Heating Circuit ZONE Controller RVA 46.531/109 Zonal temperature controller for control of a lowtemperature heating system, for use with condensing gas boilers Instructions for the INSTALLER INDEX Page

More information

- Data Brochure Universal Reset Module 422

- Data Brochure Universal Reset Module 422 - Data Brochure Universal Reset Module 422 D 422 08/07 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough-in Wiring Rough-in

More information

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control. product selection data Compact comfort module DHW management possibility Multi zone option control Easy installation Comfort module with two-zone kit Single-zone comfort module Comfort Module Range for

More information

product overview ProControl

product overview ProControl product overview ProControl 2016 product overview ProControl 2016 4 The company AFRISO Sp. z o.o. was founded in 1997. Since that time we keep doing our best to increase AFRISO brand awareness among Installers.

More information

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE Release January 2001 CONTENTS 1.0 GENERAL CHARACTERISTICS... 4 1.1 MAIN CHARACTERIS TICS... 4 2.0 USER INTERFACE (CODE C5121230)... 5 2.1 DISPLAY... 5 2.2 MEANING OF THE LEDS...

More information

1. GENERAL INSTRUCTIONS Carefully read the instructions contained in this instruction booklet and store booklet in a safe place.

1. GENERAL INSTRUCTIONS Carefully read the instructions contained in this instruction booklet and store booklet in a safe place. FUTURIA power Sold and serviced by: Hurlcon Heating. 90 Hanna Street Noble Park VIC 3174 Ph: 03 9554 2275 INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE 1 1. GENERAL INSTRUCTIONS Carefully read the

More information

USERS MANUAL FOR GAS BOILERS

USERS MANUAL FOR GAS BOILERS USERS MANUAL FOR GAS BOILERS PLEASE READ THE MANUAL CAREFULLY: IT CONTAINS IMPORTANT INFORMATION REGARDING SAFETY, INSTALLATION, USE AND MAINTENANCE OF THE APPLIANCE MODELS: NOVADENS 24 NOVADENS 24C NOVADENS

More information

D3000. Installation & Setup Guide

D3000. Installation & Setup Guide Page 1 of 15 17483-00 Rev B s1 April 2009 Contents Description Page Safety... 3 Installation Standards 3 Specification. 3-4 Circuit Board Connection 5 Mounting Dimensions 6 Installation Procedure 6 Mechanical

More information

INSTALLATION & USER MANUAL

INSTALLATION & USER MANUAL INSTALLATION & USER MANUAL HC Digital Automatic Humidistat (Y3760) CONTROLS 506808-01 3/2016 Supersedes 6/2011 picture goes here THIS MANUAL MUST BE LEFT WITH THE HOMEOWNER FOR FUTURE REFERENCE NOTICE

More information

Installation & Maintenance Instructions KAPTIV ZERO AIR LOSS CONDENSATE DRAIN 04/08

Installation & Maintenance Instructions KAPTIV ZERO AIR LOSS CONDENSATE DRAIN 04/08 Installation & Maintenance Instructions KAPTIV ZERO AIR LOSS CONDENSATE DRAIN 04/08 GENERAL OPERATION The KAPTIV is a zero-air-loss, electronic level sensing condensate drain. By installing the KAPTIV

More information

TECHNICAL DOCUMENTATION DTR AIR WATER HEATERS IN STEEL CASING S SERIES

TECHNICAL DOCUMENTATION DTR AIR WATER HEATERS IN STEEL CASING S SERIES TECHNICAL DOCUMENTATION DTR AIR WATER HEATERS IN STEEL CASING S SERIES ENG Technical documentation Table of contents. INTRODUCTION. PRECAUTIONS. TRANSPORT.3 PACKAGE CONTENT.4 USE AND PRINCIPLE OF OPERATION.

More information

- Data Brochure Steam Control 279

- Data Brochure Steam Control 279 - Data Brochure Steam Control 279 D 279 12/07 The tekmar Steam Control 279 can operate a single on-off steam boiler or an on-off steam valve using outdoor reset. The control determines the on time of the

More information

User Guide. OPTYMA TM Control Three-phase AK-RC 103

User Guide. OPTYMA TM Control Three-phase AK-RC 103 User Guide OPTYMA TM Control Three-phase AK-RC 103 Table of contents Page General...3 Description...3 Functions and main characteristics...3 Applications...3 Technical characteristics of OPTYMA TM Control

More information

CONTENTS. 1. Safety recommendations 2 Table of warning and attention plates 3. Description of the unit 4. Operation 5. Handling

CONTENTS. 1. Safety recommendations 2 Table of warning and attention plates 3. Description of the unit 4. Operation 5. Handling CONTENTS 1. Safety recommendations 2 Table of warning and attention plates 3. Description of the unit 4. Operation 5. Handling 6. Installation 6.1 Plates 6.2 Dimensions 6.3 Location 6.4 Free room 6.5 Installation

More information

TECHNICAL MANUAL CVM 3000 C 5030 CV/04-99 GB

TECHNICAL MANUAL CVM 3000 C 5030 CV/04-99 GB Summary 1 CONNECTIONS... 8 1.1 TEMPERATURE PROBES...8 1.2 PRESSURE PROBES...9 1.3 LOW VOLTAGE DIGITAL INPUTS...10 1.4 LIVE DIGITAL INPUTS...11 1.5 RELAY OUTPUTS...12 2 VOLTAGE/FREQUENCY INPUT...13 3 POWER

More information

Installation Guide. ECL Comfort 310, application A Table of Contents

Installation Guide. ECL Comfort 310, application A Table of Contents 1.0 Table of Contents 1.0 Table of Contents... 1 1.1 Important safety and product information..................... 2 2.0 Installation... 5 2.1 Before you start.....................................................

More information

REMOTE CONTROL FOR CHILLER MYCHILLER

REMOTE CONTROL FOR CHILLER MYCHILLER REMOTE CONTROL FOR CHILLER MYCHILLER GENERAL FEATURES... 3 MAIN FUNCTIONS AND EQUIPMENT:... 3 LCD DISPLAY... 4 KEYBOARD... 5 BOARD CONFIGURATION... 7 LIST OF MAIN PARAMETERS... 7 CONFIGURATION OF MAIN

More information

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw Multifunction chillers for indoor installation. Cooling Capacity: 22 222 Heating Capacity: 25 236 Scroll compressors EC Plug Fans Plate type heat exchangers EER up to 3,12 COP up to 3,84 ESEER up to 4,01

More information

STREBEL S-CB + Cascade Kits

STREBEL S-CB + Cascade Kits STREBEL S-CB + Cascade Kits Models + 60 - + 80 - + 100 - + 120 PX 120 - + 10 - + 180 Installation & Operating Manual 2x60 up to 12x180 Please read and understand before commencing installation and leave

More information

Instructions for installation

Instructions for installation Instructions for installation Read this notice carefully before installing, maintaining or repairing this appliance! The symbol indicates important information that you must take into account to avoid

More information

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

1 DOCUMENT REVISION CONTROL ELEMENTS... 9 CONTENTS Contents 1 DOCUMENT REVISION... 8 2 SOFTWARE VERSION... 8 3 BASIC DESCRIPTION... 8 4 CONTROL ELEMENTS... 9 4.1 BASIC DISPLAYS...10 4.2 CONTROL KEYS...11 4.2.1 Rotary button (Press / Turn)...11

More information

1 Dimensions Installation Mains/boosted cold water inlet Connection to the system Drain Dimension for fixing 6

1 Dimensions Installation Mains/boosted cold water inlet Connection to the system Drain Dimension for fixing 6 Electronic Filling Device (EFD) Installation and Maintenance Instructions Contents 1 Dimensions 3 1.1 Installation 4 1.1 Mains/boosted cold water inlet 4 1.2 Connection to the system 5 1.3 Drain 5 1.4

More information

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional.

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional. Page 1 of 5 Application The Single Plate heat interface unit (HIU) for the generation of instantaneous domestic hot water and the direct supply of space heating. This HIU provides hydraulic separation

More information

CALEFFI. Solar storage-to-boiler thermostatic connection kit series 01164/09 GB. Function

CALEFFI. Solar storage-to-boiler thermostatic connection kit series 01164/09 GB. Function Solar storage-to-boiler thermostatic connection kit 6-63 series REGI STERED BS EN ISO 900:000 Cert. n FM 64 UNI EN ISO 900:000 Cert. n 0003 CLEFFI 064/09 GB Function The solar storage-to-boiler connection

More information

Empty unit Cover Water Total weight 15 kg 8 kg 10 kg 33 kg

Empty unit Cover Water Total weight 15 kg 8 kg 10 kg 33 kg DE LUXE Substation Introduction The HERZ DE LUXE Substation is a firmly mounted unit for providing hot water. In contrast to a hot water boiler which heats and then stores the water before it is being

More information

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB T_SMT_0609_GB 4,9 49,5 kw Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans INDEX SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3 CE CONFORMITY... 3 WORKING

More information

INSTRUCTION MANUAL REMOTE CONTROL DEVICE EASYREMOTE

INSTRUCTION MANUAL REMOTE CONTROL DEVICE EASYREMOTE INSTRUCTION MANUAL REMOTE CONTROL DEVICE EASYREMOTE Technical features Guide to LCD symbols Guide to keys Technical features Supply by communication bus Number of temperature levels 2 (DAY / NIGHT) Temperature

More information

Technical documentation

Technical documentation Technical documentation AIR WATER HEATERS IN STEEL CASING S SERIES MODELS: REVENTON GROUP S1-3S REVENTON GROUP S2-3S REVENTON GROUP S3-3S REVENTON GROUP S4-3S ENG TECHNICAL DOCUMENTATION Table of contents

More information

INSTALLATION MANUAL. RD SERIES Digital Electric Water Heater Wall-hung Unvented

INSTALLATION MANUAL. RD SERIES Digital Electric Water Heater Wall-hung Unvented INSTALLATION MANUAL RD SERIES Digital Electric Water Heater Wall-hung Unvented WELCOME Dear Customer, Thank you for choosing the RD Series electric water heater, with an exclusive electronic temperature

More information

BIX B-One 100 kw INSTALLATION GUIDE

BIX B-One 100 kw INSTALLATION GUIDE BIX B-One 100 kw INSTALLATION GUIDE Dear Customer, We thank you for choosing our product. The Bix B-One 100 Kw is a burner of advanced concept and technology, with a high reliability and construction quality.

More information

ARGO (Technical Support) 2201 Dwyer Avenue Utica, NY (Corporate Sales) 85 Middle Road

ARGO (Technical Support) 2201 Dwyer Avenue Utica, NY (Corporate Sales) 85 Middle Road ARGO (Technical Support) 2201 Dwyer Avenue Utica, NY 13501 (Corporate Sales) 85 Middle Road An ISO 9001-2000 Certified Company Dunkirk, NY 14048 www.argoindustries.com P/N 240005498A, Rev. 1.5 [02/07]

More information

Heat Interface Units for decentralised water heating in district heating systems

Heat Interface Units for decentralised water heating in district heating systems www.herz.eu Heat Interface Units for decentralised water heating in district heating systems HERZ Heat Interface Units High-quality decentralised water heaters with heating connection, for drinking water

More information

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ SERIES: EWCBZ - Heat pump MODELS: 70, 80, 00, 0, 60, 00, 40, 00, 50 COOLING CAPACITIES from 5,9 kw to 78,5

More information

Temperature Controller CC24-7 UNIBOX USER S MANUAL Legion Dr. Mason, MI USA October 2010 Ph. (517) Fax (517)

Temperature Controller CC24-7 UNIBOX USER S MANUAL Legion Dr. Mason, MI USA October 2010 Ph. (517) Fax (517) 3 4 Temperature Controller USER S MANUAL Aerotech, Inc. FORM: QM1386 4215 Legion Dr. Mason, MI 48854-1036 USA October 2010 Ph. (517) 676-7070 Fax (517) 676-7078 FOR CUSTOMER USE Enter the serial number

More information

Technical documentation DTR AIR WATER HEATERS IN EPP CASING HC-3S SERIES

Technical documentation DTR AIR WATER HEATERS IN EPP CASING HC-3S SERIES Technical documentation DTR AIR WATER HEATERS IN EPP CASING HC-S SERIES PL TECHNICAL DOCUMENTATION Table of contents Heating coil: made of aluminum and copper. The temperature of the heating factor is

More information

VSL II QUICK START GUIDE

VSL II QUICK START GUIDE This Quick Start Guide must be left with owner and should be hung on or adjacent to the boiler for reference. VSL II QUICK START GUIDE DIRECT-VENT SEALED COMBUSTION CONDENSING BOILER ~ GAS-FIRED BOILER

More information

Installation and operation manual

Installation and operation manual Installation and operation manual - + BRC1HHDAW BRC1HHDAS BRC1HHDAK English Table of contents Table of contents 1 General safety precautions 2 1.1 For the user... 2 1.2 For the installer... 2 2 About this

More information

EXPERT TRI-STAR. Temperature controller. User s Manual

EXPERT TRI-STAR. Temperature controller. User s Manual Temperature controller r s Manual WARNINGS The warranty can be void if this product is used in a manner not specified by the manufacturer. Every effort has been made to ensure that this manual is complete,

More information

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories > HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION Available range Unit type IP Reversible heat pump (reversible on the refrigerant side) ECO-FRIENDLY REFRIGERANT GAS Versions (heat recovery) VB Base

More information

Advance Split

Advance Split Engineering Data Manual Aqu@Scop Advance Split Air-to-Water DC Inverter Split Heat Pumps Models 005, 008, 012 & 014 2 to 16 kw Strength Points Most efficient heating technology with variable speed compressor.

More information

Operating instructions

Operating instructions The energy you need Operating instructions Betacom 3 24c -A (H-GB) 30c -A (H-GB) GB, IE Contents Contents 1 Safety... 3 1.1 Action-related warnings... 3 1.2 Intended use... 3 1.3 General safety information...

More information

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique

More information

Electronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions

Electronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions Electronically controlled instantaneous water heater CEX 9-U: 27910-50 C models Installation instructions For 50 ºC models, the appliance delivers water not exceeding 50 ºC in accordance with AS3498. 1.

More information

THE REMEHA HIU RANGE Installation, operation and maintenance manual December 2017

THE REMEHA HIU RANGE Installation, operation and maintenance manual December 2017 Installation, operation and maintenance manual December 2017 CONTENTS The following instructions are for the E70/5, E70/9, T60/5 & T60/7. Introduction... 3 Declaration of conformity... 3 Symbol key...

More information

G a

G a G2474 74 319 0081 0 a en Installation Instructions Heating controllers RVP3... Installation Place of installation In a dry room, e.g. in the boiler room Mounting choices: Control cabinet (in the front,

More information

Table of Content LT 5165-UL

Table of Content LT 5165-UL Table of Content LT 565-UL. User manual.... Legal regulations... 3. Safety instructions... 3 4. Technical information... 4 5. Technical data... 4 6. Performance Graph... 5 7. Mounting... 6 8. Mounting

More information

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol. Process Analysis Systems Chem Energy Pharm Food Water Stratos Eco 2405 CondI Inductive Conductivity Measurement Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement

More information

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS TSEK VENCO Havalandırma ve Makina San.ve Tic. A.Ş. 2004. Cad. No:5 45400 OSB Turgutlu MANISA / TURKİYE Tel: +90 (236) 332

More information

Operation manual FR EN NL DE IT. intended for professionals and end users. To be saved for future consultation

Operation manual FR EN NL DE IT. intended for professionals and end users. To be saved for future consultation Document n 1408-1 ~ 11/02/2010 Control Box FR EN NL DE IT Operation manual intended for professionals and end users To be saved for future consultation Fujitsu General (Euro) GmbH Werftstrasse 20 40549

More information

Flow Factor ~

Flow Factor ~ Flow Factor ~ 216-765-4231 The DHC-E series is tested and certified by WQA against NSF/ANSI 372 for lead free compliance. STIEBEL ELTRON Inc. 17 West Street West Hatfield MA 01088 Tel. 413-247-3380 Fax

More information