Metering systems 0548EN April 2014
|
|
- Cathleen Preston
- 5 years ago
- Views:
Transcription
1 08EN April 0 0U8 GEY - Y - Y (GE- series) / 00 00A/ L/ Versions and product codes Product code Type Heat exchanger nominal power GEY, - GEY and production GEY and production Table - Product codes, 9, 8 Jig with valves GEY08 GEY08 GEY08 GEY08 GEY08 GEY08 GEY Main features Painted (RAL900) steel cabinet, for external installation, with key lock. Double heat exchanger configuration in parallel (except GEY): priority on the production of domestic hot water with respect to the heating function. handling with controlled temperature Spacers for the meters. Expansion vessel, safety valve and high efficiency circulator (/), all comply with ErP Directive (009//CE). Motorised zone valve for heating. / connections. Dynamic balancing valve, R0A series. WRAS certified components for the domestic hot water circuit. Technical data Max. working temperature of the primary circuit and secondary circuits (heating and ): 90 C Max. working pressure of the primary circuit and secondary : bar. Maximum differential pressure for the primary side = bar (due to the priority valve) Maximum working pressure of the heating secondary circuit: bar (safety valve setting) Nominal primary flow: 0 80 C for, kw (GEY) 9 80 C for 9 kw (GEY) C for 8 kw (GEY) Figure - GE- GEY - GEY Description GE series is composed of heat interface units for heating and (Domestic Hot Water) production; they are fed by means of hot water from centralised boiler plant (e.g. district heating). The present version uses a configuration of two heat exchangers in parallel (except GEY), this has two principal advantages: Parallel and non-intermittent handling of the domestic hot water and heating functions. Higher safety, the heating circuit is a sealed pressurised system should there be any leaks within property only a small amount of water will be discharged. The adopted configuration is an innovative variant with the use of thermostatic actuators, and an automatic balancing of the primary flow particularly practical and reliable, as can be seen from the following data.
2 Metering systems 08EN April 0 0U8 GEY - Y - Y (GE- series) / 00 00A/ L/ Optional components Components On each satellites, it is possible to install the following optional components: Energy meter (M-Bus): product code GEY9 Respect the flow direction in figure. The flow temperature sensor of energy meter has to be installed into the appropriate housing (fig.-). Domestic hot water meter (M-Bus): product code GEY90 Respect the flow direction in figure. Insulation in expanded PEx: product code GEY80 Jig with valves and / connections: GEY08 & GEY08 (table and fig.) Jig with valves, filters and Ø mm connections: GEY08 & GEY08 (table and fig. & ) F G C D GEY The installation should be undertaken by suitably qualified and authorised personnel only. Observe the EU norms and regulations concerning the use (installation, fixing, etc.), the operation, the recalibration and the replacement the meters. Please refer to the assembly instructions supplied with any meter. GEY08 JIG WITH VALVES GEY08 - JIG WITH VALVES (possibility of connections from above) GEY08 JIG WITH VALVES GEY08 - JIG WITH VALVES (possibility of connections from above) GEY GEY A B C D E F G Legenda Automatic air vent Dynamic balancing valve Motorised heating way zone valve Spacer pipe for energy meter Temperature probe housing for energy meter Primary by-pass Lockshield valve for heating 8 Thermostatic head RL for temperature control of heating 9 Priority valve for domestic hot water function 0 Heat exchanger, domestic hot water function Flow switch TMV & TMV thermostatic mixing valve Spacer pipe for domestic hot water meter Check valve Heat exchanger, heating function Sensor of thermostatic head RL Automatic air vent 8 Automatic air vent 9 Expansion vessel 0 Ball valve for circulator maintenance High efficiency circulator Manometer Safety valve Electric box A: Cold water inlet B: Cold water outlet C: Primary outlet D: Primary inlet Figure components PRIMARY PRODUCTION Figure type of jigs JIGS COMPONENTS GEY08, GEY08 RISCALDAMENTO CONTROLLI E: Hot water outlet F: outlet G: inlet FLUIDO DALL ALTO. Metallic frame. Ball valve to isolate the unit.filter.dirt separator. Joint that allows the connection from above from below and. Ball valve to allow the inspection of the filter. System pipes, Ø mm FLUIDO DAL BASSO Figure - Jig components
3 08EN April 0 0U8 GEY - Y - Y (GE- series) / 00 00A/ L/ Operation P : cold inlet (fig.-a), cold outlet (fig.-b), hot outlet (fig.-e). In place of the brass spacer (fig.-) a domestic hot water meter can be installed. A TMV+TMV thermostatic mixing valve regulates the temperature of (Domestic Hot Water). GEY E A C D F G P HEATING: inlet (fig.-g) and outlet (fig.-f). The circuit is simply composed of the heat exchanger and a circulator. As it deals with a closed circuit, the equipment is completed by: expansion vessel, safety valve, and manometer. A filling loop system (supplied) should be fitted on the cold water and heating flow pipe. PRIMARY: inlet (fig.-d) and return (fig.-c). The energy meter can be installed in place of the spacer (fig.-) by installing the inlet temperature probe in the appropriate housing (fig.-). For GEY, the primary circuit operates only for the heating circuit; the primary circuit is composed of a dynamic balancing valve, an automatic air vent, a heat exchanger and a thermostatic valve with remote sensor that regulates the power for the heating circuit. The zone valve can control the heating by means of a thermostat (not supplied). For GEY-, the primary circuit is divided into two sides: one is for the heating handling (similar to the one described above), the other is for the production of. If the flow switch is activated (by a request), the priority valve closes the heating side and gives power to the production side. 8 mm F B W E A A B E GEY - GEY Automatic air vent A: Cold water inlet B: Cold water outlet C: Primary outlet D: Primary inlet Figure Operating scheme C D F G Legend Heat exchanger Dynamic balancing valve F Flow switch Motorised way zone valve Manual air vent and discharge E Spacer for energy meter Manometer P Temperature probe housing for energy meter Primary by-pass Priority valve Pressure switch Ball valve for circulator maintenance Thermostatic head RL Check valve B W E: Hot water outlet F: outlet G: inlet TMV & TMV thermostatic mixing valve lockshield valve Spacer for domestic cold water meter Sensor of thermostatic head RL Expansion vessel High efficiency circulator Safety valve R0AY0 dynamic balancing valve (/ ) - p: 0-00 kpa l / sec l / h Setting Table R0A regulation
4 08EN April 0 0U8 GEY - Y - Y (GE- series) / 00 00A/ L/ Protection and safety systems Danger of burns and electric shocks. Access to the HIU should be by suitably qualified and authorised personnel only. Electrical connections On the top left of the HIU there is an electrical box IP (fig.-) containing a relay for the priority valve controlled by means of the flow switch and the control and supply of the circulator (fig.-0). It is important that the access to the HIU is made only by suitably qualified and authorised personnel: the cabinets are provided with key locking. THERMOSTAT request NC C NO from user EARTH 0 V live NEUTRAL Controls and maintenance circuit pressure Periodically inspect the pressure of the heating circuit by using the pressure gauge (fig.-): the pressure value must be maintained over bar (pressure values under bar can damage the circulator by cavitation). A pressure switch with 0,8 bar settings is provide to protect the circulator. stops if the pressure is below 0,8 bar due to the pressure switch device. Please, refill the system to restart the circulator. A filling loop is provided and must be fitted between the cold feed and heating flow (the HIU has no internal filling loop); during filling be aware that the safety valve will activate at bar (fig.-): Warning: danger of burns. In order to eliminate the air in the heating circuit, use the air vent (fig.- and fig.-). EARTH to satellite white HEATING CIRCULATOR PRESSURE SWITCH red 8 9 brown HEATING -WAY ZONE VALVE ACTUATOR Figure a Electrical connections fo GEY satellite THERMOSTAT request NC C NO blue from user EARTH 0 V live NEUTRAL Safety valve Periodically operate the manual handwheel of the safety valve (fig.-). Be careful the discharge of water may be hot. Warning: danger of burns. PRESSURE SWITCH white red Adjustments Domestic hot water temperature Adjust the temperature of the domestic hot water using the thermostatic mixing valve (fig.-). Ensure that the valve is commissioned under normal system conditions. The valve must be commissioned to suit site conditions and the desired outlet temperature set by the installer. With normal supply conditions established and the hot and cold water supplies running, open the outlet and leave running. Remove the cap and release the locking nut from the temperature spindle. Using an 8 mm allen key rotate the temperature adjustment spindle anticlockwise to increase the mixed water temperature or clockwise to reduce the mixed water temperature - at all times ensuring the probe of the thermostat is under the flowing water. The use of a digital thermostat when setting the valve is recommended, once the desired outlet temperature is reached, re-fit the locking nut to the temperature spindle to prevent unauthorised adjustment of the valve and replace the cap on the valve body. Adjust the heating temperature using the thermostatic head (fig.-): Position Temperature [ C] Provide a safety thermostat for the low temperature heating applications. EARTH to satellite 8 9 brown HEATING CIRCULATOR HEATING -WAY ZONE VALVE ACTUATOR blue FLOW SWITCH request Figure b Electrical connections fo GEY- satellites blue PRIORITY VALVE -way Technical data Supply voltage for circulator: 0 V / 0 Hz. Maximum electrical power for the HIU: W (for GEY) 9 W (for GEY, GEY) Electrical power for the circulator: W / 0,0 0, A. demand - thermostat connection The heating demand should be given via the normally open contact of the thermostat (N.O. contact, see fig.) to terminal n 8; the common contact of the thermostat has to be connected to connection n on the relay. For the connection of the thermostat use a -conductor cable with 0, mm section. No polarity need be complied with for the connections. M-Bus For the connection of the M-Bus data transmission cable to the concentrator refer to the thermal energy meters datasheet. brown blue brown black A A RELAY If you notice that the rating temperature of the heating is higher than the set value, the flow of the primary may be too high and the thermostatic head is not able to close. To balance the heating production functions, you can adjust the dynamic balancing valve (fig.-) but note that it also affects the production. Finally, it is possible to change the heating power by modifying the circulator using the red knob (fig.-0).
5 08EN April 0 0U8 GEY - Y - Y (GE- series) / 00 00A/ L/ Small heat exchanger (GEY) Primary circuit,00 F.O. 0,0 0,0 0,,0 0,0 Q [m /h] Figure Primary circuit for domestic hot water production, dynamic balancing valve fully open - Radiators [m /h] Max,, Table Primary circuit data for radiator heating. - Radiant floor [m /h] Max, 0,0 temperature (radiators - C) 80 C C C 0 ( C) 90 (9 C) 0 ( C) temperature (radiators -8 C) 0 C C 0 C 80 (9 C) Table Primary circuit data for floor radiant heating. 0 (9 C) 0 (0 C) p [m H O] Figure 8 flow rate diagram. Q [l/h]
6 08EN April 0 0U8 GEY - Y - Y (GE- series) / 00 00A/ L/ Small heat exchanger (GEY) Primary circuit,00 F.O.,00 F.O. 0,0 0,0 0,0 0,,0 0,0 Q [m /h] Figure 9 Primary circuit for domestic hot water production, dynamic balancing valve fully open Lockshield valve n of turns 0,0 0,,0 0,0 Q [m /h] F.O. Kv 0, 0,9,, - Radiators [m /h] Max,, Table Primary circuit data for radiator heating. - Radiant floor [m /h] Max, 0,0 temperature (radiators - C) 80 C C C 0 ( C) 90 (9 C) 0 ( C) temperature (radiators -8 C) 0 C C 0 C 80 (9 C) Table Primary circuit data for floor radiant heating. 0 (9 C) 0 (0 C) Figure 0 Primary circuit for heating, lockshield valve and dynamic balancing valve fully open p [m H O] Figure flow rate diagram. Q [l/h] Domestic hot water production temperature ( 0-0 C),00,8, l/min l/h kw 80 C C 0 C C 0 C (,9 C) 0 (, C) 8 (, C) 9 (0, C) 80 ( C) (8, C) 90 (0, C) 0 (,9 C) 90 (,9 C) 9 (, C) 0 (, C) 0 (, C) Table Primary circuit data for domestic hot water production. 8 (, C) 00 (,8 C) 80 (, C) 0 ( C) 0,0 0,0 0,,0 Q [m /h] 0,0 Kv Description Ref. figure,8 Domestic hot water A-E, Domestic cold water A-B Figure Hydraulic data for hot and cold domestic water circuits.
7 08EN April 0 0U8 GEY - Y - Y (GE- series) / 00 00A/ L/ Large heat exchanger for domestic water production (GEY) Primary circuit,00 F.O.,00 F.O. 0,0 0,0 0,0 0,,0 0,0 Q [m /h] Figure Primary circuit for domestic hot water production, dynamic balancing valve fully open. - Radiators [m /h] Max,, Table 8 Primary circuit data for radiator heating. - Radiant floor [m /h] Max, 0,0 temperature (radiators - C) 80 C C C 0 ( C) 90 (9 C) 0 ( C) temperature (radiators -8 C) 0 C C 0 C 80 (9 C) Table 9 Primary circuit data for floor radiant heating. 0 (9 C) 0 (0 C) Lockshield valve n of turns 0,0 0,,0 0,0 Q [m /h] F.O. Kv 0, 0,9,, Figure Primary circuit for heating, lockshield valve and dynamic balancing valve fully open p [m H O] Figure flow rate diagram. Q [l/h] Domestic hot water production temperature ( 0-0 C),00,, l/min l/h kw 80 C C 0 C C 0 C (, C) (,8 C) 0 (, C) 90 (8,9 C) 90 (0, C) 9 (,9 C) 0 (8, C) 0 (9, C) 890 (0, C) 00 (, C) (8, C) 0 (0, C) 80 (, C) 00 (, C) 80 (, C) Table 0 Primary circuit data for domestic hot water production. 0 (, C) 80 (, C) 00 (, C) 00 (, C) 8 (,9 C) 0 (, C) 00 (8, C) 0,0 0,0 0,,0 0,0 Q [m /h] Kv Description Ref. figure, Domestic hot water A-E, Domestic cold water A-B Figure Hydraulic data for hot and cold domestic water circuits.
8 08EN April 0 0U8 GEY - Y - Y (GE- series) / 00 00A/ L/ Electronically controlled high-efficiency pump / (0 V) Pump operating Automatic constant pressure difference (recommended). H [m] p-costante Automatic variable pressure difference. green continuous green flashing Automatic air vent routine (0 min duration): the pump runs alternatively with high and low s to help air bubbles to collect and to go to the air vent in the installation. Normal running. LED - errors Automatic operation for air elimination ,,, Q [m /h] P [w] m 0 0 0,,, Q [m /h] Figure - features m 0, m m m m max green/red flashing red flashing NO LED Abnormal situation (pump functional but stopped): ) Undervoltage or overvoltage ) Wrong temperature (fluid or room temperature) Pump stopped (permanent error: the pump need a manual reset). It can be necessary to change the pump. No power supply: ) Pump is not connected to power supply: check cable connection. ) LED is damaged: check if pump is running. ) Electronics are damaged: change pump. Dimensions Normative references UNI EN EN 0 EN 0 Measuring Instruments Directive 00//CE (MID) ErP Directive 00//CE 0 WRAS approvals Ref. fig. Components Certificate number - Gaskets 0 9, Heat exchanger 00 Thermostatic mixing valve Check valve 0900 Ref. fig. Components Certificate number A B C X E Y G Filter and gaskets 0 D F 80 Table WRAS approvals. 0 Legend A: Cold water inlet B: Cold water outlet C: Primary outlet D: Primary inlet Figure 8 Dimensions in mm E: Hot water outlet F: outlet G: inlet X: Hole for safety valve drain Y: Hole for electrical cables Additional information For additional information please check the website or contact the technical service: ' * consulenza.prodotti@giacomini.com This pamphlet is merely for information purposes. Giacomini S.p.A. retains the right to make modifications for technical or commercial reasons, without prior notice, to the items described in this pamphlet. The information described in this technical pamphlet does not exempt the user from following carefully the existing regulations and norms on good workmanship. Giacomini S.p.A. Via per Alzo, 9-80 San Maurizio d Opaglio (NO) Italy 8
R557R EN January 2012
R7R- 077EN January 0 07U 00 00 00 WITH HIGH TEMPERATURE MANIFOLDS Example: R7RY0 + RAY00 R7R- WITH THERMAL ENERGY METERING Description R7R- group is used for the regulation of the fixed point heating for
More informationMetering systems 0371EN July 2016 User satellites, GE556 series Versions GE556Y301, GE556Y302
071N July 01 Versions GY01, GY0 igure 1 GY01 GY0 Description The G user satellites are the ideal metering solution in condominium systems with the centralised production of heating water and zone-based
More informationPRE-ASSEMBLED MANIFOLD FOR HEATING SYSTEMS WITH THERMOSTATIC MIXING
PRE-ASSEMBLED MANIFOLD FOR HEATING SYSTEMS WITH THERMOSTATIC MIXING R557 SUMMARY 1. APPLICATION 1. OPERATING 2. COMPONENTS 3. OVERALL DIMENSIONS 4. APPLICATION EXAMPLE 6. POSITIONING OF THE HEAD WITH THERMOSTATIC
More informationAir treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings
0932EN October 2017 CHARACTERISTIC DATA Air flow rate [m 3 /h] 200 Pressure available (factory configuration) [Pa] 15 Moisture removed (26 C - 65% R.H. - inlet water 15 C) [l/24h] 24,7 Max. absorbed electric
More informationCALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB
4 RESET ON DHW CH FAULT SATK wall-mounted heat interface unit Fitted for connection to DHW storage SATK4 series ACCREDITED CALEFFI 6/4 GB ISO 9 FM 64 ISO 9 No. The latest generation of heat interface units
More informationBoiler room components 0463EN October 2013
40 90 Boiler room components 0463EN October 2013 Contact regulation thermostat Electrical connections Terminal 1: common input Terminal 2: opens the circuit with the increase in temperature Terminal 3:
More informationGIACOMINI HEAT INTERFACE UNITS
GIACOMINI HEAT INTERFACE UNITS GENERATION 5 CONTENT 06. FEATURES & BENEFITS 08. TWIN HEAT INTERFACE UNIT 11. SINGLE HEAT INTERFACE UNIT 14. TECHNICAL DATA 17. COMPONENTS 20. ENERG MONITORING 23. DIMENSIONS
More informationSATK50-60 series CONTENTS. Recess Mounted Heat Interface Unit - SATK series INSTRUCTIONS FOR INSTALLATION, COMMISSIONING AND MAINTENANCE
780EN www.caleffi.com Recess Mounted Heat Interface Unit - SATK series SATK0-60 series INSTRUCTIS FOR INSTALLATI, COMMISSIING AND MAINTENANCE Function The SATK series HIU allows independent control of
More informationChapter 7 DIRECT AND INDIRECT THERMAL ENERGY METERING
Chapter 7 DIRECT AND INDIRECT THERMAL ENERGY METERING 7 216 USER MODULES FOR DIRECT METERING GE555 STANDARD CONNECTIONS DIMENSIONS (L x H x D) mm BALANCING UNITS FOR SANITARY WATER METERS GE555Y461 3/4
More informationDIRECT AND INDIRECT THERMAL ENERGY METERING
Chapter 7 DIRECT AND INDIRECT THERMAL ENERGY METERING User modules for direct metering 232 Heat interface units for direct metering 236 Thermal energy meters, water maters, data centralization system 243
More informationSATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production
SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production SATK0 - SATK0 series ACCREDITED ISO 900 FM 009/ GB replaces dp 009/ GB Function The latest generation of Heat Interface
More informationSystems for central heating
www.far.eu Highlight Systems and Components for central heating Components for renewable energy systems Pressfar Fittings Presetting valves and thermostatic head Balancing devices Zone valves Metering
More informationInstallation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump
Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Reduced Installation time Precision regulation Minimal tooling required 100% tested prior to packaging High quality
More informationMetering systems 0670EN March 2017 Volumetric thermal energy meters for use in a boiler room GE552-1 series
Threaded version Flanged version GE552-1 Description The GE552-1 volumetric meters are used in the boiler room, to measure the heating and conditioning energy. They are strongly recommended for energy
More informationRadiators: indirect energy metering and components
ENERGY MANAGEMENT E001EN PRODUCTS Radiators: indirect energy metering and components Heat cost allocators for energy consumption metering, thermostatic heads, valves and lockshield valves, air vent valves,
More informationRADIANT PANEL SYSTEM CONTROL QUICK GUIDE
RADIANT PANEL CONTROL QUICK GUIDE 05 RADIANT PANEL CONTROL Terms and definitions The system temperature regulation can be carried out in only two basic ways: Flow rate control of the medium feeding the
More informationR586R. Distribution and Regulation units. Datasheet 0861EN 04/2019 R586RY103 R586RY102 R586RY101 R586RY104
R8R Distribution and Regulation units Datasheet 08EN 0/09 R8RY0 R8RY0 R8RY0 R8RY0 Unit with insulation and actuator (optional) R8RY R8RY R8RY R8RY R8R distribution units control heating and cooling for
More informationT. +44 (0) E.
ModuSat Single Plate-Double Circuit (SPDC) Heating Interface Units The Evinox ModuSat satellite heating system has been designed to provide apartments and communal housing developments with independent
More informationThermostatic head with wax sensor
Combined with valves covered by EN215 01 november 2004 ı Technical communication n da Use In modern society research concerning comfort in the home becomes a factor of prime importance. In order to obtain
More informationDEVIATING VALVES ART K063
FUNCTION The flow diverter valve Art.307 makes it possible to supply a branch circuit. Prepared to receive our electro-thermal controls Art. 978, 979, 980 or our thermostatic heads with remote sensor Art.
More informationheat interface units A BOILER WITHOUT A FLAME
A BOILER WITHOUT A FLAME heat interface units Communal Heat Networks A central boiler house will generate heat which is distributed through a network of pipe to each home or apartment in the building.
More informationT. +44 (0) E.
Twin Plate Heat interface unit for indirect heating and instantaneous domestic hot water with electronic thermostatic control. Designed for wall-mounting. Application The is the complete solution for hot
More informationModuSat TP. Energy. Heat Interface Units
Energy Twin Plate Heat interface unit for indirect heating and instantaneous domestic hot water with electronic thermostatic control. Designed for wall-mounting. Application The is the complete solution
More informationHyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1
HyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1 INSTALLATION, COMMISSIONING AND OPERATING INSTRUCTIONS Contents Unit as delivered
More informationModuSat TP. Energy. Heat Interface Units
Energy Twin Plate Heat interface unit for indirect heating and instantaneous domestic hot water with electronic thermostatic control. Designed for wall-mounting. Application The is the complete solution
More informationCALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function
Thermostatic regulating unit for heating systems 66 series ACCREDITED ISO 9 FM 6 8/7 GB replaces dp 8/ GB Function The thermostatic regulating unit performs the function of keeping the flow temperature
More information4-way valve with thermostatic option with variable centre distance and pre-adjustment for Single pipe and Dual pipe systems.
4-way valve with thermostatic option with variable centre distance and pre-adjustment for Single pipe and Dual pipe systems. CT3101.0_00 EN June 2016 o o o o Valve with pre-adjustment; Variable centre
More informationHot Water Energy Storage THE HOT WATER PEOPLE HEAT INTERFACE UNIT ENGINEERED FOR ULTIMATE HEATING COMFORT AND MAXIMUM SYSTEM EFFICIENCY
Hot Water Energy Storage HEAT INTERFACE UNIT ENGINEERED FOR ULTIMATE HEATING COMFORT AND MAXIMUM SYSTEM EFFICIENCY THE HOT WATER PEOPLE Hot Water Energy Storage THE HOT WATER PEOPLE Providing premium hot
More informationHerz York Direct Heat Interface Unit
www.herzvalves.com Herz York Direct Heat Interface Unit The Modern Solution for Apartment Heating and Domestic Hot Water Services General Description The Herz York Direct HIU is suitable for all community
More information80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features
Comfort Module Range for Monobloc Heat Pumps Quality Management Systems Comfort module with two-zone kit Single-zone comfort module 8HMA Nominal heating capacity 4- kw Nominal cooling capacity 4- kw The
More informationIdeasandformsinevolution
Ideasandformsinevolution TYPE natural draught room sealed electric diverting valve RTN 24 CTN 24 E RTFS 24 CTFS 24 E DUA PLUS is a natural draught or room sealed forced draught wall hung gas boiler, with
More informationINSTALLATION AND SERVICING
INSTALLATION AND SERVICING LOGIC HIU (Heat Interface Unit) Indirect 75 Indirect 50 Direct MT Direct HT When replacing any part on this appliance, use only spare parts that you can be assured conform to
More informationA/23 MFFI - A/27 MFFI
A/23 MFFI - A/27 MFFI G.C.N. 47-6-0 / 47-6-2 Servicing Instructions Type C Boilers LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER TABLE OF CONTENTS Page No.. SERVICING INSTRUCTIONS. Replacement of
More informationMikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc
Mikrofill Ethos Condensing combination boiler Maintenance Instructions 24cc IMPORTANT Benchmark Installation, Commissioning and Service Record Log Book is enclosed in your customer information pack. This
More informationWall-mounted compact indirect heat interface unit SATK30 series Safety instructions Dimensions Technical specifications Installation Commissioning
78.0EN www.caleffi.com Wall-mounted compact indirect heat interface unit SATK0 series INSTRUCTIS FOR INSTALLATI, COMMISSIING AND MAINTENANCE Function The SATK series HIU allows independent control of heat
More informationMercury Mixing Kit (Code: ME1053)
Mercury Mixing Kit (Code: ME1053) The installation and commissioning of the UFH mixing kit system must be exclusively performed by qualified personnel in accordance with the national guidelines and/or
More informationHIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler
HIGH POWER VICTRIX PRO 2 ErP High power, wall-hung condensation boiler MAIN INDEX INDEX 1 VICTRIX PRO 35-55 2 ErP SPECIFICATIONS...5 2 VICTRIX PRO 80-100-120 2 ErP SPECIFICATIONS...6 3 VICTRIX PRO 35-55
More informationCALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB
Set point thermostatic regulating unit 8 series FM 65 00 CALEFFI 090/8 GB replaces dp 090/5 GB Function The thermostatic regulating unit is made to be used in radiant panel systems, in combination with
More informationTHERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES
ST.07.05.00 THERMOSTIC SINGLE-PIPE AND DOUBLE-PIPE VALVES 1. Art.1420 THERMOSTIC SINGLE-PIPE VALVE Single-pipe valves allow manual, thermostatic or thermo-electric regulation. Separation of the lockshield
More information80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.
product selection data Compact comfort module DHW management possibility Multi zone option control Easy installation Comfort module with two-zone kit Single-zone comfort module Comfort Module Range for
More informationTEMPRA. Wall Mounted Fan Flue System boiler. Wall mounted fanned flue boiler INSTALLATION AND USE INSTRUCTIONS. Appr. nr. B A - CE 0063 AQ 2150
Wall Mounted Fan Flue System boiler Appr. nr. B 94.04 A - CE 0063 AQ 2150 Phone numbers: Installer Service Engineer Serial N Wall mounted fanned flue boiler INSTALLATION AND USE INSTRUCTIONS Please read
More informationInstallation and operation manual for mixing modules FH-MJB and FH-MJC
40 30 20 50 60 Installation and operation manual for mixing modules FH-MJB and FH-MJC Application The FH-MJB and FH-MJC mixing shunts are designed to supply floor heating areas up to approx. 40 m 2 (from
More informationGENERAL CATALOGUE MICROMETRIC, THERMOSTATIC VALVES THERMOSTATIC VALVES MANUAL VALVES LOCKSHIELDS ACCESSORIES AND SPARE PARTS
GENERAL CATALOGUE MICROMETRIC, TERMOSTATIC VALVES TERMOSTATIC VALVES MANUAL VALVES LOCKSIELDS ACCESSORIES AND SPARE PARTS SUMMARY 1. USE 2. MICROMETRIC TERMOSTATIC VALVES 3. TECNICAL DATA 3. MATERIALS
More informationheat interface units A BOILER WITHOUT A FLAME HIU Single PHE options
A BOILER WITHOUT A FLAME HIU Single PHE options heat interface units Communal Heat Networks A central boiler house will generate heat which is distributed through a network of pipe to each home or apartment
More informationCONTROL UNIT FOR UNDERFLOOR HEATING SYSTEMS
ST.04.04.00 ONTROL UNIT FOR UNERFLOOR HETING SYSTEMS Low temperature control unit Low+high temperature control unit 1. ONTROL UNIT PPLITION The FR control unit is suitable for systems combining both high
More informationACCREDITED. Product range Code A2L Pre-assembled set point temperature regulating unit with manifolds and box, with UPM3 Auto L pump
Set point temperature regulating unit series ACCREDITED ISO 9 FM / GB replaces dp / GB Function The temperature regulating unit is made to be used in radiant panel systems, in combination with distribution
More informationForced draught gas burner
Installation, use and maintenance instructions Forced draught gas burner Code Model Type 3751982 GAS 3 519T80 291 (3) - 02/2010 DECLARATION Declaration of conformity in accordance with ISO / IEC 17050-1
More informationKOSPEL S.A. UL. OLCHOWA KOSZALIN
Used product can't be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment for recycling. Appropriate utilisation
More informationCALEFFI. Modulating temperature regulating unit for heating and cooling with high temperature distribution kit. series /04 GB.
Modulating temperature regulating unit for heating and cooling with high temperature distribution kit series cert. n ISO / GB Function The modulating temperature regulating unit with high temperature distribution
More informationInstallation and Commissioning Instructions
Installation and Commissioning Instructions FMU Floor Mixing Unit with Lowara Ecocirc Class A Pump Pre-assembled TM Thermostatic Mixing Control Group and manifold with either lockshields or flowmeters,
More informationPRE-ASSEMBLED RADIANT CONTROL PANEL INSTALLATION MANUAL
FloorHeat PRE-ASSEMBLED RADIANT CONTROL PANEL INSTALLATION MANUAL Thank you for purchasing this radiant control panel assembly. Following are some important notes that will make the installation successful.
More informationTECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT
1. GENERAL INFORMATION 1.1 Applications page 2 1.2 Operation» 2 1.3 Performances» 2 1.4 Product range» 2 1.5 Selection software» 2 2. DIMENSIONS AND WEIGHTS» 3 3. COMPONENTS 3.1 Structure» 4 3.2 Coils»
More informationTrade Product List 2013 BIOMASS ACCESSORIES
Trade Product List 2013 BIOMASS ACCESSORIES BIOMASS SYSTEM COMPONENTS Constant Temperature Control Accessories CONSTANT TEMPERATURE CONTROL PRODUCTS Order Code Description of Package and Contents Pictures
More informationR146C. Adjustable magnetic dirt separator. Versions and product codes. Datasheet 0840EN 10/2018
R146C Adjustable magnetic dirt separator Datasheet 0840EN 10/2018 The R146C adjustable magnetic dirt separator separates and removes debris inside hydraulic circuits of modern heating and cooling systems.
More informationServicing Instructions Type C Boilers G.C.N: LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER
Servicing Instructions Type C Boilers G.C.N: 4-6-0 47-6-08 47-6-09 47-6-3 LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER TABLE OF CONTENTS Page No.. SERVICING INSTRUCTIONS. Replacement of Parts 3.2
More informationContact person RISE Date Reference Page Björn Folkeson P03675B 1 (11) Energy and circular economy
Contact person RISE Björn Folkeson 2017-08-15 7P03675B 1 (11) Energy and circular economy +46 10 516 54 46 bjorn.folkeson@ri.se Gemina Termix A/S Navervej 15-17 DK-7451 SUNDS Danmark Testing of a HIU according
More informationAqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND
Aqua Balance AquaBalance TM CONTROL MODULE QUICK START GUIDE 10 1 Domestic Hot Water temperature setpoint decreasing button 2 Domestic Hot Water temperature setpoint increasing button 3 Central Heating
More informationDomestic hot water (DHW) The substation can be supplied with connection pipes for DHW cylinder on the supply or return line.
MAKING MODERN LIVING POSSIBLE VX Solo II Substation for single-family, semi-detached and terraced houses as well as flats District heating substation for indirect heating. With connection pipes for W cylinder.
More informationFHM-Cx Mixing Shunts for Floor Heating
FHM-Cx Mixing Shunts for Floor Heating Application Mixing shunt FHM-C5/C6 (UPS pump) The Danfoss compact mixing shunts are used for regulation of flow and supply temperature in hydronic floor heating systems.
More informationMetering Box METERING AND AMBIENT HEATING FOR HEATING SYSTEM. Overview. Application PRODUCT DATA
Metering Box METERING AND AMBIENT HEATING FOR HEATING SYSTEM Overview PRODUCT DATA The Honeywell Substations series consist of the following products: Metering Box (this datasheet) Heat Interface Unit,
More informationINSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE
INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE SPECIFICATIONS... 1 OVERVIEW... 2 PRECAUTIONS... 2 MOUNTING LOCATION... 2 CONNECTION TO BOILER PRIMARY PIPING:... 3 ELECTRICAL CONNECTION... 4 FLUSHING THE
More information1 VICTRIX ZEUS Superior kw I features
Wall-hung condensing VICTRIX ZEUS Superior kw I is the new range of wall-hung condensing boilers with 54 litre stainless steel storage tank available in two versions with nominal heat output of 26 kw and
More informationContact person RISE Date Reference Page Björn Folkeson P (13) Energy and circular economy
Contact person RISE Björn Folkeson 2017-09-21 7P03972 1 (13) Energy and circular economy +46 10 516 54 46 bjorn.folkeson@ri.se Thermal Integration Ltd 8 Curzon Road Sudbury Suffolk CO10 2XW Great Britain
More informationUser Manual for model
User Manual for model RKA 24/8 RKA 24 RKA 28 RKA 34 Wall mounted storage combi boiler premix condensing boiler User instruction CE 0694 RKA 24.8_24_28_34 - RAD - ING - MAN.UT - 1104A - DIGITECH 2 - REGNO
More informationUNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2. Version: 2018_07_19_v2.2
UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2 Version: 2018_07_19_v2.2 Abstract This is a quick reference guide for selecting the UniQ range of heat batteries for the required application. For designing a
More informationTHERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE PRODUCTION RANGE IRON PIPE CODE CONNECTION
THERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE CT0031.0_10 EN August 2016 THERMOSTATIC RADIATOR VALVES * * * * 028 * LICENSED USE OF TRADEMARK NR. 43 PRODUCTION RANGE IRON
More informationContact person RISE Date Reference Page Daniel Månsson P (13) Energy and circular economy
Contact person RISE Daniel Månsson 2018-08-07 8P04823 1 (13) Energy and circular economy +46 10 516 53 28 daniel.mansson@ri.se Flamco LTD Washway Lane, St. Helens Merseyside WA10 6PB Great Britain Testing
More informationOperating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents
1.0 Table of Contents 1.0 Table of Contents... 1........................................................................ 2 2.0 Functional description... 3 3.0 Safety notes... 4 3.1 Safety Notes general............................................
More informationUser Manual for model RK 18 RK 25 RK 34 CE 0694 RK 18_25_34 - RAD - ING - MAN.UT A - DIGITECH 2 - REGNO UNITO - EXTRAHEAT - CBD
User Manual for model RK 18 RK 25 RK 34 Premix condensing boiler User instruction CE 0694 RK 18_25_34 - RAD - ING - MAN.UT - 1104A - DIGITECH 2 - REGNO UNITO - EXTRAHEAT - CBD Technical specification by
More informationValves, controls + systems. Local and district heating technology. Innovation + Quality. Product range. for improved.
Innovation + Quality Valves, controls + systems Local and district heating technology for improved energy efficiency Product range Local and district heating technology The term Local and district heating
More informationInstallation, Operating and Servicing Instructions
EN 0 / 0 / 00 / 800 Installation, Operating and Servicing Instructions excellence in hot water EN Y000.D EN INDEX Warnings Who should read these instructions Symbols Recommendations Applicable standards
More informationTA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services
TA-COMFORT-S Prefabricated units Heating interface unit for surface heating and hot water services IMI TA / Control valves / TA-COMFORT-S TA-COMFORT-S All in one design with STAP differential pressure
More informationInstructions for installing and using HIPER HIU UK patent applied for:
Instructions for installing and using HIPER HIU UK patent applied for: 1420204.8 Installation and Operating Instructions SECTIONS 1. Important information 2. Description 3. Dimensions and components 4.
More informationUser's Instructions. Alpha CB50
User's Instructions Alpha CB50 Wall Mounted, Fan Assisted, Room Sealed, Gas Fired Combination Boiler with Unvented Hot Water Storage (From Boiler Serial No. 27B32500001) For Technical help or for Service
More informationCMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL
CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION ECO-FRIENDLY REFRIGERANT GAS INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the result of many years
More informationSIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A
cod. 6272262A GENERAL DATA Heating Data Heat Output Input (Adjustable) (Adjustable) Format 34i 11.2 34KW 45 145MJ/hr Format 34e 11.2 34KW 45 145MJ/hr General Specifications FORMAT 34i 34e Main burner injectors
More informationSATK 30 heat interface unit
heat interface unit L nt In partnership with: n imensions C C A B B A E Introduction The heat interface unit is the latest intelligent range of HIU from Altecnic. The is the complete solution for instantaneous
More informationInstallation, operating and servicing instructions
English 57-115 - 144-1 - 259 Installation, operating and servicing instructions ITALIA EN 1 ITALIA English INDEX WARnINGS 3 Who should read these instructions 3 Symbols 3 Recommendations 3 Importants notes
More informationContact person Date Reference Page Daniel Månsson P (13) Energy and circular economy
Contact person Daniel Månsson 2017-04-18 7P01636 1 (13) Energy and circular economy +46 10 516 53 28 daniel.mansson@ri.se Fortes Import Installatie Agenturen B.V. Loodsboot 26 NL-3991 CJ Houten Nederländerna
More informationAquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes
Thermostatic valve with adjustable temperature control range Technical information Tender specification: Oventrop thermostatic valve Aquastrom T plus with presetting for circulation pipes. Thermal control
More informationACCREDITED. Product range Code A2L Modulating temperature regulating unit for heating and cooling, with ALPHA2 L pump.
Modulating temperature regulating unit for heating and cooling 7 series ACCREDITED ISO FM ا ٠١١٥٢/١٥ replaces /7 GB Function The temperature regulating unit is made to be used in radiant panel systems
More informationTechnical Product Guide
FMU - Floor Mixing Unit Boxed set pre-assembled for immediate installation: The FMU Floor Mixing Unit integrates both temperature and flow management, making the single piece unit very easy to install,
More informationTechnote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional.
Page 1 of 5 Application The Single Plate heat interface unit (HIU) for the generation of instantaneous domestic hot water and the direct supply of space heating. This HIU provides hydraulic separation
More informationLight oil - kerosene burner
Installation, use and maintenance instructions Light oil - kerosene burner One stage operation CODE MODEL TYPE 374374 G3B 437T 90 (4) - 05/0 TECHNICAL FEATURES TYPE 437T Thermal power output 9 35 kw.6
More informationRVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER
Heating Circuit ZONE Controller RVA 46.531/109 Zonal temperature controller for control of a lowtemperature heating system, for use with condensing gas boilers Instructions for the INSTALLER INDEX Page
More informationDivacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production
Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production THE SIMPLEST SOLUTION FOR A CONDENSING BOILER DIVACONDENS D PLUS is the generator of condensation
More information24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.
24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers Enerwa / EnerwaPlus www.warmhaus.com Condensing-ErP Premix System Boilers 24/31-28/35-33/40 kw Warmhaus wall-hung gas combi boilers
More informationContact person Date Reference Page Björn Folkeson P (14) Energy and bioeconomy
Contact person Björn Folkeson 2016-11-18 6P06855 1 (14) Energy and bioeconomy +46 10 516 54 46 bjorn.folkeson@sp.se Caleffi S.p.A. S.R. 229, n. 25 IT-28010 Fontaneto d'agogna (NO) Italy Testing of heat
More informationHYDRAULIC SEPARATION. Product Range
YDRAULIC SEPARAON Inta s ydraulic separator provides an effective means of separation between the boiler and load circuits preventing interference between simultaneously operating circulators and providing
More informationUser Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.
User Manual for model FLOWMAX-90 Condensing water heater 85,000 BTU WARNING If the information in these instructions is not followed exactly, a fire or explosion may result, causing property damage, personal
More informationPHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE
TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE
More informationDigital Control Unit- Installation, Operation & Maintenance IMPORTANT INFORMATION
Environment IMPORTANT INFORMATION It is not anticipated that this equipment will be exposed to adverse environmental conditions without additional protection. Site the equipment in a frost free area. Ensure
More informationCITY PLUS. Wall-hung condensing boilers. ErP 24 HE 30 HE. Ready
CITY PLUS Wall-hung condensing boilers 24 HE 30 HE ErP Ready Quality first of all! Quality components Only the best components are used in the Italtherm boilers Noble materials Brass hydraulic groups,
More informationLK Heat Exchanger Pack 10 -n
LK Heat Exchanger ack 10 -n 6 9 14 2 5 15 7 4 12 11 13 10 3 14 1 Design The LK Heat Exchanger ack -10 is primarily designed for glycol based under floor heating systems that must be isolated from other
More informationFHM-Cx Mixing Shunts for Floor Heating
Data Sheet FHM-Cx Mixing Shunts for Floor Heating Application A self-acting proportional regulator is used to regulate the supply temperature. The regulator ensures that the desired supply temperature
More informationUnvented Calorifier Range. Operating and Maintenance Manual. For Models & 500
Unvented Calorifier Range. Operating and Maintenance Manual. For Models 125 300 & 500 Telephone 08456 448802 Fax 08456 448803 Emial info@mhgheating.co.uk Web www.mhgheating.co.uk TABLE OF CONTENTS. Section
More informationConvertible radiator valve for one-pipe systems, centre distance 35 mm
Convertible radiator valve for one-pipe systems, centre distance 35 mm 56 series ACCREDITED ISO 900 FM 65 033/6 GB Function 56 series convertible radiator valves are used on one-pipe radiator systems.
More informationPivot Stove Hydronic Installation Guide
Pivot Stove Hydronic Installation Guide Install Location When installing the header tank - install directly above the appliance. There needs to be a continual rise between the appliance and the header
More informationFunction series Thermo-electric actuator electric supply 230 V (ac) or 24 V (ac/dc)
onvertible radiator valve for one-pipe and two-pipe systems series ARIT 0/ G ISO 0 M ISO 0 No. 000 unction The series convertible radiator valve can be used both on one-pipe and two-pipe radiator systems.
More informationNIKE Star 24 3 E. Instantaneous wall-hung with open chamber boilers. NIKE Star 24 3 E
Instantaneous wall-hung with open chamber boilers Small wall-mounted open chamber, conventional flue instant boiler. General features. is a wall-mounted, open combustion chamber, conventional flue generator
More information