How to use the BTRM in Remote Enclosures

Similar documents
Added password for IP setup page : Password must be in IP format!

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

APPLICATION DATA SHEET

A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE INSTRUCTIONS

REMOTELY OPERATED STENCH GAS RELEASE SYSTEM. Front Panel View Remote Activated Stench Gas Release System 240 Volt AC Supply

Sensaphone 400 Telemetry System Integration

JUNO-NET. Fire Alarm Control Panel OPERATION & MAINTENANCE MANUAL

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

Frequently asked questions: Intelligent Transmitter Series

Silent Alert Fire Safe System

Public Safety DAS Annunciator Panel

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

RTD TEMPERATURE SENSING SYSTEM

This Tech Note provides detailed procedures to configure Remote Response objects to trigger an alarm and acknowledge it via or SMS.

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

Batt-Safe Battery String Monitoring System

20 Light Remote Annunciator

APPLICATION DATA SHEET

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 2800PPM. Merlin CO2 Monitor 2800ppm. American Gas Safety LLC 1

rvm4c Installation Guide Remote Video Module

1U ULTRA Compact System

Setup Instructions. This manual is only valid for A36D/TPSD Chargers. equipped with a 341S control card with P341S0012 or P341S0013 software

New Silent Alert Fire Safe System

Vess A2000 Series. IO Terminal Board. User Information. Version PROMISE Technology, Inc. All Rights Reserved.

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

1 MXS Strada: connect and configure alarm LEDs

PTE0705 Electric Fence Monitor

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge


21-light Remote Annunciator. Owner s Manual

INSTALLATION INSTRUCTIONS

Register the Gateway via PC. Package Content. Gateway Installation. 1 x Gateway 1 x Voice Siren 1 x IP Camera*

Digital Marine Exhaust Temperature Alarm

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

GLOBAL. InstallatIon & operation manual

Symmetra MW Modbus Data Points

VPS3 Installation Manual

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES

RMS-I-DE-01 Smoke Detector

SAFETY WARNINGS. Power cable to the alarm system. Automatic two-pole circuit breaker. Cable from power distribution board

UNC100 Integra Manual

user manual Document No , Revision 03 November 2015

EOS INTERFACE GUIDE AND POINTS LIST For EOS BTCII Firmware Version J1239D-570 and newer

User Guide. HTM Nurse Call. In the event of requiring assistance, please contact your Installer/Supplier.

SLX Power. modular power system listed for all low voltage needs Access / Fire / Security / CCTV / Mass Notification

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring

ALARM OUTPUT MODULE. Product #7736

wireless. web-based. worthy of the name RACO.

Functional Performance Test

The Remote alarm Panel, TYPE RAPv2

5U Compact System. Installation Manual V1.0. Manufactured by Enatel Ltd. 321 Tuam Street PO Box Christchurch New Zealand

Ozone Generator and Ozone PCB Tests and Fault Troubleshooting

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

Dryer Controller M720

RQE Series Temperature Controllers

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

Ethernet General Purpose

P2267 NETWORK INTERFACE

Product Manual. TZ Analog Sensors. TZ Sensors 8115CF 8116CF 8117CF 8118CF. Date: January 2015 Document Number: _B

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

The Kentec driver connects to the Kentec Syncro range of fire detection panels. Available for Commander and ObSys.

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

Instruction manual. W440 AIS Sart Sniffer

GSM RFID VOICE Alarm System

Interface Modules for SENTRI

Planning Elevator Relay Groups Programming Millenium for Windows Software

YachtSafe GPS Alarm Manual

C-Bus Four Channel General Input Unit Installation Instructions

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

A36D/TPSD Modbus TCP SCADA INTERFACE INSTRUCTIONS

Network based smoke alarm - using Arduino and iphone

Gas detection control system CM80-ID

ZLM4 OEM Technical Manual

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

Interfacing with the ADAM Module

SMS GSM Alarm Messenger

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

Signature Series 418 Mhz COMMUNICATOR RECEIVER INSTALLATION AND OPERATIONS MANUAL

Regulations Governing Fire Protection Systems That will be connected to the Town of Wayland Municipal Fire Alarm System.

INSTRUCTION MANUAL. stay ahead - stay informed 1. THE APP

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

XP95/Series 90 Test Set

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

RS485 MODBUS Module 8AI

User Manual. Dryer Controller M720

PROTECTION CABINETS SUPERVISION CABINETS FOR AUTOMATIC EXTERNAL DEFIBRILLATORS (AEDs)

EMERGENCY COMMUNICATIONS SYSTEMS SUPPLEMENTARY RECORD OF INSPECTION AND TESTING

Y-Plant Alert. Alarm Annunciator and Sequence of Event Recording System. BU 04M01A02-01E-A

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

INSTRUCTION MANUAL A131 High Level Audible Warning System / Battery backup

Pipo Communications. Model ST-888. DTMF ANI/ENI Display Decoder

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

Home & Yard Alert Long Range System Home & Yard Alert Extended Long Range System

Installer Certification Expiration. Terms

Roth Touchline. German quality since Quick and easy user manual 1/10

Transcription:

How to use the BTRM in Remote Enclosures Part Number: BTRM-200 Product Release Date: April 01, 2013 Software version: BTRM2_2013-05-06_2316_DNPV2V130D The Ventev Battery Test Remote Monitor (BTRM) has two independent, isolated relay contacts for alarm indications. The contacts are normally open when power is off. The user can select normally open or normally closed under an alarm condition. The maximum relay ratings for the contact are 60 Volts, 80 milliamps. It is not recommended that it be used to operate AC line connected equipment. The two dry contacts are available for basic RTU functionality. Example configurations include: Door Alarm AC Power Off DC Power On Door Alarm The most common application for the relay contacts is a door alarm. The door alarm consists of an adjustable, polycarbonate pin switch and a door bracket for the pin switch. A DC voltage is applied to the pin switch as shown in Figure 1. The negative contact of the alarm does not have to be connected in order to complete the circuit, since the negative contacts of the BTRM are tied together internally. DC OK -V V V ADJ DC OK POWER SUPPLY N L DC TERMINAL BLOCK BTRM200 Batt C. Batt C. Load P.S Load 1 Load 2 Batt - Charger - P.S - GND Load 1- Load 2- Alarm1 or I/O1 Alarm1 or I/O1 I/O - Alarm2 or I/O2 Alarm2 or I/O2 - DOOR SWITCH Figure 1: Door Alarm Wiring Configuration

Once the alarm electrical connections have been made, the BTRM I/O needs to be configured. Go to www./btrm, and click on the Port Options tab on the left. Then go to the BTRM I/O options page (configure arrow in Figure 2). Under the I/O channel being used for the alarm, set the Digital Input Alarm if > 2V (setting arrow in Figure 2). SETTING CONFIGURE Figure 2: BTRM I/O Options for Door Alarm The door alarm status is shown on the BTRM status home page (Figure 3). When the door on the enclosure is closed, the polycarbonate pin switch will be open-circuited. There is no voltage going to the contact on the BTRM. The alarm indication will show 0V for Analog V and False for Digital In. When the door on the enclosure is opened, the polycarbonate pin switch will close the circuit. There will be a voltage going to the contact on the BTRM. The alarm indication will show the voltage from the DC terminal block for Analog V and True for Digital In. True indicates that an alarm message has been sent from the BTRM to the IT network.

ALARM INDICATION Figure 3: BTRM Status Home Page Showing Door Alarm Indication AC Power Off Another application for the relay contacts is an AC Power Off alarm. The AC Power Off alarm works in conjunction with DC OK dry contacts of a power supply. A positive DC voltage is applied to the BTRM relay via the DC OK contacts as shown in Figure 4. The negative contact of the BTRM I/O connects to the negative DC voltage. DC OK -V V V ADJ DC OK POWER SUPPLY N L DC TERMINAL BLOCK BTRM200 Batt C. Batt C. Load P.S Load 1 Load 2 Batt - Charger - P.S - GND Load 1- Load 2- Alarm1 or I/O1 Alarm1 or I/O1 I/O - Alarm2 or I/O2 Alarm2 or I/O2 - Figure 4: AC Alarm Wiring Configuration

Once the alarm electrical connections have been made, configure the BTRM I/O by going to www./btrm. Click on the Port Options tab on the left, then go to the BTRM I/O options page (configure arrow in Figure 5). Under the I/O channel being used for the alarm, set the Digital Input Alarm if < 1V (setting arrow in Figure 5). CONFIGURE SETTING Figure 5: BTRM I/O Options for AC Alarm The AC alarm status is shown on the BTRM status home page (Figure 6). When the AC power to the enclosure is present, the DC OK relay in the power supply is closed. A closed-loop circuit is made between the power supply and the BTRM. The alarm indication will show the voltage from the DC terminal block for Analog V and False for Digital In. When the AC power to the enclosure is disconnected, the DC OK relay in the power supply is open. The circuit between the power supply and the BTRM is now open. The alarm indication will show 0V for Analog V and True for Digital In. True indicates that an alarm message has been sent from the BTRM to the IT network.

ALARM INDICATION Figure 6: BTRM Status Home Page Showing AC Power Indication DC Power On An application similar to the AC Power Off alarm is the DC Power Alarm. This alarm works in conjunction with a DC power distribution panel. The positive and negative contacts of the DC distribution connect to the respective BTRM relay contacts as shown in Figure 7. BTRM200 Batt C. Batt C. Load P.S Load 1 Load 2 DC OK -V V V ADJ DC FUSE DISTRIBUTION Batt - Charger - P.S - GND Load 1- Load 2- DC OK POWER SUPPLY Alarm1 or I/O1 Alarm1 or I/O1 - Alarm2 or I/O2 Alarm2 or I/O2 - N L DC TERMINAL BLOCK Figure 7: DC Alarm Wiring Configuration

Once the alarm electrical connections have been made, configure the BTRM I/O by going to www./btrm. Click on the Port Options tab on the left and go to the BTRM I/O options page (configure arrow in Figure 8). Under the I/O channel being used for the alarm, set the Digital Input Alarm if < 1V (setting arrow in Figure 8). CONFIGURE SETTING Figure 8: BTRM I/O Options for DC Alarm The DC alarm status is shown on the BTRM status home page (Figure 6). When power is applied to the DC distribution, there is a voltage going to the contact on the BTRM. The alarm indication will show the voltage from the DC terminal block for Analog V and False for Digital In. When the DC power is removed from the DC distribution, there is no voltage going to the contact on the BTRM. The alarm indication will show 0V for Analog V and True for Digital In. True indicates that an alarm message has been sent from the BTRM to the IT network.

ALARM INDICATION Figure 6: BTRM Status Home Page Showing AC Power Indication Additional Applications The two independent, isolated relay contacts in the BTRM can also be used for: Checking component voltages Activating a camera when an alarm indication occurs Monitoring thermal conditions via thermal couple Relaying low battery capacity alarm to SCADA radio. Operating external DC relays to control audible alerts or alarm lights