S170 - SOLAR STORAGE-TO-BOILER CONNECTION KIT WITH THERMAL INTEGRATION

Similar documents
DEVIATING VALVES ART K063

CALEFFI. Solar storage-to-boiler thermostatic connection kit series 01164/09 GB. Function

Thermostatic mixing valves with interchangeable cartridges

Dati Tecnici Technical Data

teide termo plus+ HEATING SERIES SCOPE THERMOSTATIC VALVES SERVICE CONDITIONS COMPONENTS TECHNICAL SHEET 07/2017 IP20060 PAG. 1/9

BF2 GLASSLINED CYLINDERS WITH TWO REMOVABLE STAINLESS STEEL HEAT EXCHANGERS ( LITRES)

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341

Thermostatic mixing valves with replaceable cartridge for centralized systems

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341.

ECO HOT WATER Air-water heat pump for domestic hot water with integrated solar panels and remote control via App GB 02. Ecoenergy.

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

FOR INSTALLING AND USING

CALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB

SCHEDE TECNICHE. Display ACS 150 L/200

THERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES

521 Series. MixCal adjustable three-way thermostatic mixing valve. Installation, commissioning and service instructions

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

Ø24 Ø34 CP POLINI WITH KNOB CHOKE ELASTIC CONNECTION POLINI CP STARTER ARIA A POMELLO, ATTACCO ELASTICO

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe

THERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE PRODUCTION RANGE IRON PIPE CODE CONNECTION

Installation, commissioning and servicing instructions

CALEFFI. water heater tank mixing valve. TankMixer. 520 series 01267/17 NA

Sifoni Cromati e pilette Chrome plated siphons and waste

ACCREDITED. Function. Code /3 unit without cold water circuit outlet kit

4-way valve with thermostatic option with variable centre distance and pre-adjustment for Single pipe and Dual pipe systems.

generatori di vuoto monostadio pvp 2 e pvp 3

Development of an advanced control system for chillers

Installation, commissioning and servicing instructions. Technical Characteristics. -Lead Plumbing Law Certifi ed by IAPMO R&T

CELEST A. High efficiency air/water cooled chillers 8 38

heat interface units A BOILER WITHOUT A FLAME

caleffi hydronic valves page 1 of 12

i-nrg 0061m 0061t Reversible heat pump with inverter compressor, total heat recovery, air source for indoor/outdoor installation 16,3 kw PRANA

Multi-channel centrifugal pumps

Certificato numero: 300 RIVA TECNOIMPIANTI S.R.L. UNI EN ISO 9001 : 2015 ISO 9001 : 2015

Nature technological innovation FLORIM stone functionality personalisation 12mm

Akva Lux TDP-F District heating flat station for direct heating and domestic hot water systems

Mercury Mixing Kit (Code: ME1053)

HW 22 District heating substation for indirect heating and domestic hot water systems

IMBALLAGGI P.K. s.a.s. Via Campegi, 87/89, I VIGEVANO PV tel telefax

INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM OD (FOR EXTERNAL USE)

Akva Vita TDP District heating flat station for direct heating and domestic hot water systems

Metering systems 0548EN April 2014

SAITEK srl. Serie. < Automatic burner control unit > Casalgrande (RE) ITALY Tel Fax

USERS MANUAL FOR GAS BOILERS

Akva Vita TDP-F District heating flat station for direct heating and domestic hot water systems

Operating Guide. Termix Solar A+/B+ 1.0 Table of Contents. 1.0 Table of Contents

displei studio baciocchi 2010

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

Akva Vita Instantaneous water heater

K18 PLANT MANUAL. Heating and DHW

INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM

CONTROL CABINET for cascade boiler systems

function Adjustable thee-way thermostatic mixing valve... connections 1/2", 3/4", 1" NPT male union and sweat union

"XL" Presse idrauliche a caldo. Italpresse S.p.A. Presse idrauliche

Installation and Operation Instructions K36E Modular Heating Circuit - DN 25 Boiler charging set

CALEFFI. Thermostatic mixing valves, low-lead, high-flow series 01256/18 NA. Replaces 01256/15 NA

Eco ULTRA - Heat Pump Buffer Tanks - Arctic Heat Pumps

Adjustable three-way thermostatic mixing valve... connections ½", ¾", 1" NPT male union and sweat union and ¾" press

Thermostatic head with wax sensor

HORIZONTAL HOT WATER CYLINDER WHPF BO

INDEX. Installation recommendation

Akva Lux VX District heating substation for indirect heating and domestic hot water systems

ACCREDITED. Product range Code A2L Pre-assembled set point temperature regulating unit with manifolds and box, with UPM3 Auto L pump

INDIRECT WATER HEATERS

INSTRUCTIONS FOR HOBS PISL1CZI PISL20ZI PISL40ZI PISL40Z* PISL4CZI PISL904CZI PISL1004CZI PISL1163CZI PISF4CZI PISF904CZI PISF1004CZI PISF1163CZI

IST 03 C ANTEA CONDENSING EN INSTALLATION, USE & MAINTENANCE MANUAL

RETTANGOLO J RETTANGOLO J

Convertible radiator valve for one-pipe systems, centre distance 35 mm

Operators manual Slim/B Water heater

product overview ProControl

FORMENTERA CTN RTN CTFS RTFS

Model T-45NL: Certified in compliance with ASSE 1017, 1069, 1070, and ANSI/NSF 61 PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING AND OPERATING!

white blue cobalt bordeaux light oak (rovere)

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

In/Out. woodcraft. and more

INSTALLATION USE AND MAINTENANCE USEFUL ADVICE

ACCREDITED. Product range Code A2L Modulating temperature regulating unit for heating and cooling, with ALPHA2 L pump.

USER S MANUAL. Rectifier 1 10 A/10 48 V for Kliar Line Art

User Manual for model

Use and maintenance manual

THERMOSTATIC VALVES HUEGLI TECH

Ideasandformsinevolution

INDEX. Installation recommendation

1 NORMS AND REGULATIONS Guarantee norms: Environmental notes: Identification:... 15

NATURAL CIRCULATION SYSTEMS NS-SOL SOLAR INSTALLER, TECHNICAL ASSISTANCE CENTRE AND USER MANUAL

B2009 compact. Dal 1901 COD

CONTROL PANEL. RIELLOtech PRIME ACS INSTALLATION, OPERATION AND MAINTENANCE MANUAL

CALEFFI. Anti-condensation recirculation and distribution unit. 281 series 01224/14 GB. Replaces dp 01224/12 GB. Function

WARNINGS FOR THE USER: Connect BASE conforms to: Low Voltage Directive 73/23/EEC. Electromagnetic Compatibility Directive 89/336/EEC

SIRENE ANTINCENDIO E EVACUAZIONE FIRE ALARM AND EVACUATION SOUNDERS

Controllers for refrigeration EVBOX1 data-logging extension

Wall Hung Boiler Room Thermostat OR30 OT Thermostat

Installation Instructions

HEAT INTERFACE UNITS (Sanitary Hot Water Only)

OPERATION AND MAINTENANCE BOOK. Glycol Deck 250 PREAMBLE

HKF 8180 Operating instructions

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function

aquablend thermostatic mixing valves

CELEST. Air/water cooled chillers and heat pumps 6 41

Transcription:

FUNCTION The solar storage-to-boiler connection kits automatically control and optimize the terminal energy contained in a solar water storage, ensuring that domestic hot water is distributed throughout the system at the controlled optimum temperature. They ensure that users always receive hot water at the set temperature and switch the boiler on if the temperature of the water coming from the solar storage falls below the set point. PRODUCT CODE SIZE 93S170AE06 G ¾ TECHNICAL SPECIFICATIONS Body: Brass EN12165 CW617N, chrome plated Springs: stainless steel Seals: EPDM PEROX (high thermal resistance) Max. working pressure: 10 bar (static); 5 bar(dynamic) Adjustment temperature range: 30-60 C Factory set: 38±2 C Max. inlet temperature 110 C Max. inlet pressure ratio: 2:1 bar Connections: G3/4 M Union seals: fibre high thermal resistance Diverter setting: 45 C±2 C Max. working pressure: 10 bar DIMENSIONS CODE A B C D E F G H Weight (Kg) S170 G ¾ 63.5 285 40 53 80 132 38 1.6 ATTENTION!: LOCK THE NUTS BEFORE STARTING-UP THE HYDRAULIC SYSTEM pag. 1

OPERATING PRINCIPLE Hydraulic diagram 1)Solar Thermostatic mixing valve 2)Solar Diverting valve 3) Non-Return valves NON-RETURN VALVES To prevent undesired backflows of fluid in systems with mixing valves we recommend using non-return valves. Our kit S170 includes a non-return valve at the entrance of cold and hot water systems (see sketch above, part. 3) INSTALLATION Before using the mixing valve, make sure all pipes are clean to prevent equipment malfunctions; we also recommend installing water filters. ASSEMBLY The assembly of the mixing valve requires qualified personnel in accordance with the current regulations and using adequate temperature measurement tools. CONSTRUCTION DETAILS The product design guarantees a 360 connection thanks to its rotating connections which suit any system needs, as shown in the picture. Art. S170 is made by exposing each component to thermal stress tests to avoid malformations due to hot temperatures which compromise their function. All materials used also guarantee drinkable water. pag. 2

OPERATING PRINCIPLE The diverting valve is located at the entrance of the kit receiving hot water coming from solar panels. According to the temperature calibration the valve automatically diverts the water between the domestic system and the hot-water heater. The valve provides the water flow by exploiting solar energy and reducing as much as possible the use of the hot-water heater. At the exit of the kit there is an anti-burn thermostatic mixing valve which sends the water to the users controlling and restricting the temperature. DISPOSITIVO ANTISCOTTATURE Negli impianti di produzione di acqua calda per uso sanitario con accumulo, al fine di prevenire la pericolosa infezione chiamata legionellosi è necessario mantenere l acqua ad una temperatura minima di 60 C per inibire totalmente la crescita del batterio che causa questa infezione. Ovviamente l acqua, a questa temperatura, non può essere utilizzata in maniera diretta in quanto può provocare ustioni. Per garantire l opportuna sicurezza è consigliabile installare un miscelatore termostatico capace di mantenere costante il valore preimpostato al variare delle condizioni di temperatura e pressione in ingresso. Il disegno a lato riportato descrive il grado di ustione in cui si può incorrere in base al tempo di esposizione e alla temperatura. Per ovviare a questo problema il miscelatore interviene in caso di eccessiva mancanza di acqua fredda in ingresso chiudendo il passaggio di acqua calda. TEMPERATURE REGULATION The temperature is adjusted using the mixing valve regulating knob. Reference conditions: Thot: 68 C Tcold: 13 C Inlet pressure: 3+3 balanced TEMPERATURE RANGE Position 1 2 3 4 5 6 C 30 35 40 45 50 60 SAFETY Use the filter in perfect condition for its intended purpose, taking into account safety legislation and any hazards that may be present. Read the assembly and start-up instructions and comply with them scrupulously before starting the system to prevent accidents and damage to the system caused by improper use. Remember that the guarantee will be forfeited in the event of any unauthorised changes or tampering with the device during assembly and construction. Comply with all safety warnings, and if you have any doubts about use or changes to parameters or functions, request the assistance of qualified service personnel. Assembly and inspection operations must absolutely be performed by qualified, authorised personnel aware of the instructions contained herein. Make sure that the equipment is turned off before beginning any work on it. pag. 3

APPLICATION DIAGRAM SOLAR SYSTEM WITH ART.S170 SOLAR STORAGE-TO-BOILER CONNECTION NATURAL CONDITION SOLAR SYSTEM WITH PUMP UNIT AND ART.S170 SOLAR STORAGE-TO-BOILER CONNECTION pag. 4

LOAD LOSS DIAGRAM pag. 5